2
General instructions: This filter is designed and manufactured to meet the highest standards of quality and workmanship. The hydrocyclone/sand separator is a simple unit, which is easy to maintain and operate. It has no moving parts or filter elements. The hydrocyclone separates sand and other solids from the water at a very small pressure loss, with an effectiveness of 90% or higher, without the pressure loss increasing or the separated material being able to accumulate. Installation: Install the hydrocyclone in a vertical position with the collection chamber at the bottom of the hydrocyclone. Pay attention to the correct flow direction: the inlet horizontal and the outlet vertical. Check whether the present flow velocity through the hydrocyclone is within the recommended values. An incorrect flow velocity will reduce the effect. When installing more than one hydrocyclone, allow enough room between the units for easy maintenance. Operation: Normal operating conditions are achieved when the differential pressure across the hydrocyclone is within the recommended values of 0.2-0.5 bar. A differential pressure below 0.2 bar will reduce the separator’s effectiveness. A differential pressure above 0.5 bar may result in increased erosion. The general rule is that: separation improves when the diameter of the hydrocyclone decreases and the differential pressure increases. The maximum working pressure is 8 bar. The filter is designed to withstand a maximum pressure of 10 bar. A pressure relief valve must be installed upstream of the filter if the pressure is not sufficiently under control. Do not open the filter cover and do not tighten it while the filter is being used or under pressure! Draining the collection chamber: Empty the collection chamber when it is 1/3 full, so it does not become full of sediment. Close the drain valve once the dirt has been removed. In the case of high concentrations of dirt, an electric valve and timer can be used for the draining process. Periodic cleaning: Stop the flow to the cyclone filter. Open the drain valve at the bottom of the collection chamber to release pressure and discharge dirt. Remove the cover (3). Remove all the sediment accumulated in the collection chamber. Thoroughly clean the inside of the empty collection chamber. Place the cover back on the collection chamber and ensure that the cover rubber (4) fits snugly. Place the handle and the tightening bracket (1) and tighten them firmly, or place the bolts and tighten them. drain valve underflow chamber 25 UDI 06/2015 Manual Hydrocyclone/Sand Separator 5000 Series Subject to modifications No liability accepted for errors or misprints

Manual Hydrocyclone/Sand Separator 5000 Series · 2016. 7. 6. · The hydrocyclone separates sand and other solids from the water at a very small pressure loss, with an effectiveness

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Manual Hydrocyclone/Sand Separator 5000 Series · 2016. 7. 6. · The hydrocyclone separates sand and other solids from the water at a very small pressure loss, with an effectiveness

General instructions:This filter is designed and manufactured to meetthe highest standards of quality andworkmanship. The hydrocyclone/sand separatoris a simple unit, which is easy to maintain andoperate. It has no moving parts or filter elements.The hydrocyclone separates sand and othersolids from the water at a very small pressureloss, with an effectiveness of 90% or higher,without the pressure loss increasing or theseparated material being able to accumulate.

Installation:Install the hydrocyclone in a vertical position withthe collection chamber at the bottom of thehydrocyclone.Pay attention to the correct flow direction: theinlet horizontal and the outlet vertical.Check whether the present flow velocity throughthe hydrocyclone is within the recommendedvalues. An incorrect flow velocity will reduce theeffect.When installing more than one hydrocyclone,allow enough room between the units for easymaintenance.

Operation:Normal operating conditions are achieved whenthe differential pressure across the hydrocycloneis within the recommended values of 0.2-0.5 bar.A differential pressure below 0.2 bar will reducethe separator’s effectiveness.A differential pressure above 0.5 bar may resultin increased erosion.The general rule is that: separation improveswhen the diameter of the hydrocyclonedecreases and the differential pressureincreases.The maximum working pressure is 8 bar.The filter is designed to withstand a maximumpressure of 10 bar.A pressure relief valve must be installedupstream of the filter if the pressure is notsufficiently under control.

Do not open the filter cover and do not tightenit while the filter is being used or underpressure!

Draining the collection chamber:Empty the collection chamber when it is 1/3 full,so it does not become full of sediment. Close thedrain valve once the dirt has been removed.In the case of high concentrations of dirt, anelectric valve and timer can be used for thedraining process.

Periodic cleaning:Stop the flow to the cyclone filter.Open the drain valve at the bottom of thecollection chamber to release pressure anddischarge dirt.Remove the cover (3).Remove all the sediment accumulated in thecollection chamber.Thoroughly clean the inside of the emptycollection chamber.Place the cover back on the collection chamberand ensure that the cover rubber (4) fits snugly.Place the handle and the tightening bracket (1)and tighten them firmly, or place the bolts andtighten them.

drain valve

underflow chamber

25 UDI  06/2015

ManualHydrocyclone/Sand Separator 5000 Series

Subj

ect t

o m

odifi

catio

nsN

o lia

bilit

y ac

cept

ed fo

r erro

rs o

r mis

prin

ts

Page 2: Manual Hydrocyclone/Sand Separator 5000 Series · 2016. 7. 6. · The hydrocyclone separates sand and other solids from the water at a very small pressure loss, with an effectiveness

Maintenance:Apply a film of grease on the thread of thespindle each year.Any damage to the protective coating of the filtermust be repaired immediately. Before applyingthe protective paint, the damaged spot must becleaned thoroughly using a steel wire brush.

Note:The size of the hydrocyclone/sand separatorshould fit the current flow velocity in the pipe.A smaller or larger separator does not have therequired circulation rate, which will affect thefiltrate quality.

The drain valve is an option and not part of thehydrocylone

In view of on-going improvements, we reservethe right to change specifications at any timewithout prior notice.Each filter comes with this manual whichincludes the installation, operating, andmaintenance instructions.

Type Unit 50307 50410 50615 50820 50830 51243 51640 52060 52460

Connection inch ¾" 1" 1,5" 2" 3" in 4"/uit 3" 4" 6" 6"

Capacity m³/h 2 - 3,5 3,5 - 7,5 7,5 - 12 11 - 17 18 - 34 35 - 52 52 - 82 98 - 160 140 - 230

Standard tank ltr 2 2 10 10 10 60 120 220 220

26 UDI  06/2015

ManualHydrocyclone/Sand Separator 5000 Series

Subject to modifications

No liability accepted for errors or m

isprints