SAFETY SENSORS
Catalog No. 11
Safe
sensor technologySa
fesse
nnssor tteechnolooggy
Ope
rational unitsOpe
rattiional unnits
Safe
light curtainsSafee
light curttaainsServicesSServices
Safe
tyguard locking
SSafe
tyguaard lockking
Safety PLCSSafety PPLC
Wire
less safetyWire
less saffettyy
Prot
ective enclosuresPr
ootec
tive enclosurres
Years of experience, innovative products, concentrated know-how in the area of machine safety
Safety solutions from a single source
3
Table of Contents
SAFIX 3
RFID safety sensor up to IP69K
Page 4
HOLDX R
The smart process guard locking - RFID
Page 12
Decentralized distributors
Safe wireless distributors
Page 32
SAFIX 1
RFID safety sensor up to IP67
Page 10
HOLDX S
Compact, magnetic process guard locking
Page 28
Order lists
Equipment and circuit examples
Page 36
4
Non-contact RFID safety sensor SAFIX 3
Compact design
22 mm hole spacing
36 mm width
Connections
5 m cable / 10 m cable
or pigtail cable M12 8-pin
High protection classes
IP 67 - IP 69K
Extended LED diagnosis
On both sides
Technology
State-of-the-art RFID sensors
Switching distance
12 mm, can also be
approached from the side
Resistant to cleaning agents Flat actuator SAFIX T6Waterproof housing
Next generation of our RFID safety sensor SAFIX
SAFIX 3 not only impresses with its compact design, but
also makes use of state-of-the-art RFID technology. It is
available in three different versions with optional low or
high coding level acc. to EN ISO 14119 provides high
protection against manipulation.
Thanks to different actuators, SAFIX 3 can be easily
and quickly installed in a broad number of applica-
tions, regardless of whether in wing door, lifting gate
or aluminum profi le.
Up to 30 units in a row
SAFIX 3 can be connected in series up to 30 times in
accordance with PLe EN ISO 13849-1. Flexible pigtail
connections allow quick and easy installation.
The number of connecting cables is signifi cantly reduced.
The extended diagnosis is shown user-friendly via three-
color LED display and thus enables rapid maintenance
and commissioning.
5
Extensive in the safety application
PLe acc. to EN ISO 13849-1
High coded acc. to EN ISO 14119
Series connection of up to 30 sensors without loss of safety
Integrated EDM function for direct connection of contactors (no safety relay required)
Manual / automatic start
Flexible in assembly and wiring
Can be used for small windows up to large security doors
High protection classes IP67 and IP69K for use in harsh environments
Suitable for the food and packaging industry in accordance with ECOLAB
Flexible wiring concept with the passive distributor XCONN or wireless distributor
Connections via fi xed 5 m and 10 m cable or M12 pigtail connection
EXCERPT FROM EN ISO 14119
5.2 Arrangement and installation of
position switches
Position switches must be arranged in such a
way that they are adequately protected against
any change in their position. To achieve this, the
following requirements must be met:
(a) the fastening elements of the position switches
must be reliable and a tool must be required to
loosen them.
If it is stated in the risk assessment that the safety switch
must be prevented from loosening (EN ISO 14119), the
screw covers supplied are a possibility to omit the safety
screws. For subsequent opening of the screws, the cover
must be opened with a special tool.
6
Extended LED diagnosis
Green Red Yellow Remark
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Sensor not actuated, voltage applied
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Sensor actuated, all inputs set correctly
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Sensor actuated, safety inputs not set (low level)
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Safety inputs set (high level), waiting for start pulse
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Actuator at the reception limit
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Teach-in process
Green Red Yellow Remark
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error safety outputs
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error safety inputs
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error safety inputs. EDM automatic: Safety relay fault. EDM manual: Faulty start impulse
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Overvoltage or undervoltage fault
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Temperature outside the permitted range
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xoff
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Wrong actuator
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Permanent lightInternal device error
Diagnostic function of SAFIX 3
Diagnosis advantages
Reduced machine downtime thanks to LED diagnostic function
- Door open / closed
- Error in input / output circuit
- Series connection - diagnosis of whether a door in the previous series has been opened
Diagnostic output for visualization on the standard PLC
7
SAFIX 3 _-A-_ _
Automatic reset
24V DC
Sicherheitsausgänge
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
ED
M
12
SAFIX _ _-A-_ _
SAFIX 3 _-X-_ _
Manual reset
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
EDM
12
Reset-Taster
SAFIX _ _-X-_ _
Sicherheitsausgänge
SAFIX 3 _-X-_ _
Manual reset + EDM
24V DC
0VK2
K1
K2
Reset-Taster
K1
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
12
SAFIX _ _-X-_ _
EDM
/Res
et
Electrical connection
Dimensioning
Sensor standard actuator T5 fl at actuator T6
5,1
2613
19
2236
4,5Ø7,6Ø
Kabel 8x0,25mm² 1000±35
5,1
13
4,5Ø
2619
2236
7,6Ø
Sicherheitssensor Betätiger
Pigtail 150 25+5-
53,43
13,4
2
Ø4,5
6,72 4031,3
6,71
5,1
2613
19
2236
4,5Ø7,6Ø
Cable 8x0,25mm² 1000±35
5,1
13
4,5Ø
2619
2236
7,6Ø
safety sensor actuator
Pigtail 150 25+5-
8
DID YOU KNOW...
what EDM stands for?
EDM stands for "External Device Monitoring” (feedback circuit)
The safety relay monitors the feedback circuits of externally connected contactors with
positively driven contacts. The signal at the EDM input is compared with the status of the
safety outputs.
When the safety output is switched on, the feedback circuit is open and when the safety
output is switched off, the EDM input 24 V is connected. The NC contacts of the contactors
with positively driven contacts are used to check whether the contactors have reached
their safe state before they are actuated again.
If a safety relay with manual reset function is used, the reset button is connected in series
with the feedback circuit contacts.
K1 K2
0V
F1 F2
24V DC
RFID sensor
24V DC
EDM
M
K1K2
K1K2 K1 K2
0V
F1 F2
24V DC
RFID Sensor
24V DC
EDM
M
K1K2
K1K2
contactor contactor
o� o� Ein Ein
Figure 1:
Safety sensor has shut down,
Contactor are switched off, motor is off,
24 V is available at the EDM input
Figure 2:
Safety sensor is switched on,
Contactors are switched on, motor running,
no voltage present at the EDM input
9
EDM function of RFID safety sensor SAFIX 3
The SAFIX 3 safety sensor and the HOLDX R smart process guard locking have not only
implemented state-of-the-art RFID technology, but also the full function of a safety switch
device with EDM function.
The SAFIX 3 / HOLDX R sensor can optionally be ordered with a manual or automatic
reset function. Downstream contactors up to a current consumption of 500 mA can be
connected directly to the safe OSSD outputs on the sensor. EDM- input monitors the
externally connected contactors with positively driven contacts.
Figure 3:
EDM function with automatic reset button
Figure 4:
EDM function with manual reset button
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
ED
M
12
SAFIX _ _-A-_ _
0VK2
K1
24V DC
0VK2
K1
K2
Reset-Taster
K1
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
12
SAFIX _ _-X-_ _
ED
M/R
eset
SAFIX 3_-A-_ _ SAFIX 3_-X-_ _
10
Non-contact RFID safety sensor SAFIX 1
SAFIX installed on a lifting gate SAFIX installed on a glass doorSAFIX installed on a wing door
Strong in safety applications
PLe acc. to EN ISO 13849-1
High coded acc. to EN ISO 14119
Series connection of up to 80 sensors without
loss of safety
Simple assembly and wiring
Can be used for small windows up to large
security doors
Flexible wiring concept with the passive distributor
XCONN or wireless distributor
Easy diagnosis
Reduced machine downtime thanks to LED diag-
nostic function
- Door open / closed
- Switching distance in limit range
- Error in the output circuit (short-circuit / cross-circuit)
- Series connection - diagnosis of whether a door in
the series has previously been opened
Diagnostic output for visualization on the stan-
dard PLC
Compact design
22 mm hole spacing
High protection class
IP 67Technology
State-of-the-art RFID sensors
Switching distance
12 mm, accessible from three sidesConnection
Plug connector M8 8-pin
LED diagnosis
On both sides
11
Extended LED diagnosis
Green Red Yellow Remark
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Input circuit OK, Operating voltage OK
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Door closed, sensor has switched
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Safety outputs have switched, switching distance near the limit
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Sensor in learning mode
Green Red Yellow Remark
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
10 minutes break after relearningDoor closed and target learned (func-tion only activated in learning mode)
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error in input circuit X1 or X2. Example: A door in a previous safety circuit is open.
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error in output Y1
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error in output Y2
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
flashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Cross circuit Y1/Y2
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
flashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Wrong or defective actuator
Diagnostic function of SAFIX 1
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
12
Sicherheitsausgänge
Electrical connection
Dimensioning
Sensor standard actuator T3 flat actuator T4
A
A
M8 8-pin
22
39,2
47,5
1910
,5
Ø 4,2
Ø 8
18
22
39,2
1910
,5
Ø 4,2
A
A
Ø 8
AA
40
60
16
7
Lifting gate protection with flat actuator SAFIX 1 on a tool stand
12
Two designs for your application
The smart process guard locking HOLDX R
HOLDX RS
In its small and compact design, the HOLDX RS enables a locking force of
600 N. In addition to the locking force of the electromagnet, the movably
supported anchor plate has a 50 N permanent magnet which prevents a
door from instant opening.
HOLDX RL
Ideal for large doors. Thanks to the locking force of 1200 N, the HOLDX RL
prevents doors from tearing open. With a slim width of only 35 mm, the
guard locking is ideal for space-saving installation on aluminum profi le
systems. Like the HOLDX RS, the guard locking has also has a permanent
magnet of 50 N, which prevents a door from opening.
INDUSTRY 4.0
The new generation of magnetic process guard lockings - Award winners, innovative and intelligent.
The HOLDX R series cleverly combines a secure non-contact RFID safety sensor with an intelligent electromagnet in a
single device. With this combination of safe position monitoring and process guard locking, the HOLDX R is universally
applicable and ensures increasing quality as well as less downtime and set-up times.
innovative smart safe
13
Flexible door offset
Through the combination of RFID technology and a
modern electromagnet, HOLDX R allows a large tolerance
in door offset and thus signifi cantly increases machine
availability even with inaccurate door guidance.
Simple installation, reduced commissioning time
Simplifi ed application
Reduced commissioning time thanks to fl exible assembly
concept on aluminum systems
Pigtail connection reduces cable diversity (straight and
angled cables)
Reduced machine downtime thanks to diagnostic function
Quick installation
600 N locking force for small fl aps
1200 N locking force for heavy doors
50 N permanent latching force (optional)
Flexible adjustment of latching force from 0-50 N via free
mobile app or desktop software
Integrated magnetic fl ux measurement for contamination
diagnosis
14
Extended LED diagnosis
Green Safe sensor function
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
OSSD input circuit available,Door closed
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xDoor opened
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
OSSD input circuit not available,Door closed
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xActuator at the reception limit,Switching distance in limit range
Green Red Blue System states
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Device start
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Teach-in process only for relearnable variant
Blue Guard locking function
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Magnet not actuated
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Door closed,Locking force available
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Door closed,Locking force not reached
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Door opened,Magnet actuated
Extended LED diagnosis
The smart HOLDX R process guard locking enables simple
and fast diagnostics thanks to LEDs on both sides. It
immediately detects if another process guard locking in
the system does not achieve the desired locking force
or if there is a fault in the input or output circuit of the
guard locking. In this way, you can clean or realign the
guard locking completely in line with the preventive
maintenance of your system.
Red Fault diagnosis
off
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
No error present
on
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Internal device error
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error safety outputs
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error safety inputs
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xOvervoltage or undervoltage
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xError door torn opened
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xTemperature outside the permitted range
fl ashes1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2xWrong RFID actuator
fl ashes
1x
3x 4x
2x 1x
1x
2x
3x
4x5x6x
7x
2x
Error magnetic fl ux measurement
15
Predictive maintenance thanks to self-monitoring
The smart HOLDX R process guard locking communicates with your standard PLC via the diagnostic outputs or via
the built-in Bluetooth interface with your mobile phone or laptop.
HOLDX R independently and intelligently monitors the application and the process as well as the downstream actua-
tors in the safety circuit. This enables you to fi nd errors quickly and easily, without the need for additional measuring
or diagnostic equipment.
Innovative, intelligent technology
Detects a system failure by magnetic fl ux measure-
ment before it occurs
Manipulation attempts can be detected subsequently
Monitoring of downstream participants and B10D
values
Monitoring of lifetime according to EN ISO13849-1,
notifi cation before exceeding for timely ordering and
replacement of spare parts.
Actuation of the door magnet during commissioning
even without a running safety PLC
Flexible adjustment of the latching force
Status information on the current locking force
Information about power interruption, short circuits
or cross circuits
Software password protection against manipulation
16
HOLDX R - standalone versions
Advantages in the safety application
PLe acc. to EN ISO 13849-1
Series connection of up to 30 guard lockings without
loss of safety
Advantages in assembly and wiring
Process guard locking is to be used as stop
High protection classes IP67 for use in harsh
environments
Flexible wiring concept with the passive distributor
XCONN or wireless distributor
Magnetic power
600 N locking force variant S
1200 N locking force variant L
50 N permanent magnet
Secure electrical locking
acc. to PLe EN ISO 13849-1
Compact design
Installation on aluminum profi les
from 35 mm construction width
Connection
fl exible pigtail cable
with M12 8-pin or M12 12-pin
LED diagnosis
Extended status display
High coding
2 coding levels acc. to EN 14119
Standard/ individually coded
Intelligent failure monitoring
By magnetic fl ux measurement
Flexible
Movable anchor plate
Diagnosis advantages
Extended diagnosis to standard PLC via one output
/ input
- Door open / closed
- Door locked
- Locking force not reached
- Door torn opened
- Error in the input circuit of the guard locking
- Error in OSSD output circuit of the guard locking
- Wrong actuator
Functional modules for Siemens / Beckhoff / Rockwell/
B&R available on the homepage for evaluation of
diagnostics
17
Safety outputspower supply
Safety sensorcoded
Magnet
Anchor plate
Actuator
OSS
D1
OU
T
+24
V D
C
GN
D
OSS
D2
OU
T
Dia
gnos
is O
UT
1 3 4 7
Safety inputs
OSS
D1
IN
OSS
D2
IN
2 65
Mag
net I
N
8
HOLDX RS1-P8-...HOLDX RL1-P8-...
LED diagnosis
Error GateLock
Safety outputspower supply
Safety sensorcoded
Magnet
Anchor plate
Actuator
OSS
D1
OU
T
+24
V D
C
GN
D
OSS
D2
OU
T
Dia
gnos
e O
UT
1 3 4 7
Safety inputs
OSS
D1
IN
OSS
D2
IN
2 6 10 11 125
Mag
net I
N
8
Rese
t
9
HOLDX RS1-P12-...HOLDX RL1-P12-...
LED diagnosis
Error GateLock
Secure electrical locking
acc. to PLe EN ISO 13849-1
Electrical connection
HOLDX R_1 standalone 8-pin pigtail without EDM function
HOLDX R_1 standalone 12-pin pigtail with EDM function
Diagnostics via an output
The Serial-Out diagnosis output of the HOLDX RS1 and
RL1 provides the higher-level PLC with up to 10 pieces
of information. The free-of-charge blocks for diagnosis
evaluation for a Siemens, Beckhoff, Rockwell or B&R
standard PLC‘s are available on our website ww.safety-
products.de.
Diagnostic input (magnet ON)
The guard locking function can be switched on via the
"magnet ON" input. If the input is activated via the
communication module on the standard PLC, the built-in
Bluetooth interface can be switched on / off.
18
Advantages of intelligent series connection
Series connection of up to 17 process guard lockings
up to PLe according to EN ISO 13849-1
Up to 170 diagnostic information are available in
the system with series connection
Each process guard locking can be controlled
individually
HOLDX R - networkable versions
Magnetic power
600 N locking force variant S
1200 N locking force variant L
50 N permanent magnet
Secure electrical locking
acc. to PLe EN ISO 13849-1
Compact design
Installation on aluminum profi les
from 35 mm construction width
Connection
2 fl exible pigtail cable
with M12 8-pin or M12 12-pin
for easy wiring
LED diagnosis
Extended status display
High coding
2 coding levels acc. to EN 14119
Standard/ individually coded
Intelligent failure monitoring
With the aid of magnetic fl ux measurement
Flexible
Movable anchor plate
Addressing without laptop & without software
Simply address the HOLDX RS2 and RL2 process guard
lockings via the selector switch. In addition to the master,
set up to 16 additional slaves once.
Evaluation of diagnostics on the standard PLC with-
out gateway
Functional modules for Siemens / Beckhoff / Rock-
well/ B&R available on the homepage for evaluation
of diagnostics
Wireless transmission of safe and non-safe diagnostic
information even with series connection via the
wireless safety PLC Safety Simplifi er
19
Safety inputs CAN
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Safety sensorcoded
Magnet
Anchor plate
Actuator
Dat
en
Cloc
k
1
GN
D
3 2 4 7 85 6
1
X2
X1
GN
D
3
not in useEDMDiagnose IN
109 11 125 6
Master
HOLDX RS2-CS-P12-...-BHOLDX RL2-CS-P12-...-B
LED diagnosisSafety outputs
OSS
D1
OU
T
OSS
D2
OU
T
7 8 2 4
Diagnose OUT
Dat
en
Cloc
k
Error GateLock
Safety inputs CAN
Safety outputs
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Safety sensorcoded
Magnet
Anchor plate
Actuator
OSS
D1
OU
T
OSS
D2
OU
T
1
GN
D
3 2 4 7 85 6
1
X2
X1
GN
D
3 2 4 7 85 6
SlaveHOLDX RS2-CC-SHOLDX RL2-CC-S
LED diagnosis
CAN
H
CAN
L
CAN
Error GateLock
Electrical connection
HOLDX R_2 slave 8-pin pigtail
HOLDX R master 12-pin pigtail with EDM function and manual or automatic reset
Safety inputs CAN
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Safety sensorcoded
Magnet
Anchor plate
Actuator
Dat
en
Cloc
k
1
GN
D
3 2 4 7 85 6
1
X2
X1
GN
D
3
Diagnose IN
5 6
Master
HOLDX RS2-CS-P8-...-BHOLDX RL2-CS-P8-...-B
LED diagnosisSafety outputs
OSS
D1
OU
T
OSS
D2
OU
T
7 8 2 4
Diagnose OUT
Dat
en
Cloc
k
Error GateLock
HOLDX R_2 master 8-pin pigtail
20
Reduction of commissioning time
Reduce your effort and do without an additional, external safety PLC or switch cabinets for the
safety technology. Thanks to the Safety Simplifi er with IP65 protection, you no longer need them.
The wiring effort of the safety components is reduced to a minimum using the safe wireless
communication.
Thanks to the two existing pigtail connections, Y-distributors and terminal boxes are no longer
necessary. The line is simply looped through from process guard locking to process guard locking.
Thus, up to 17 smart HOLDX R process guard locking act on a safety circuit. The guard lockings connected in series
are simply evaluated with the aid of a Safety Simplifi er. The communication between the robot control cabinet and
the control cabinet of the machine controller is then securely transmitted via a wireless network.
Status information can be evaluated and visualized by the standard PLC. The interface can be easily confi gured with
the free-of-charge functional modules from SSP. All information of the security chain and the diagnosis is transmitted.
Intelligent combination of series connection and high diagnostics
21
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
ED
M
12
SAFIX _ _-A-_ _
0VK2
K1
Time course of input and output functions
DID YOU KNOW...
how OSSD outputs work?
OSSD means "Output Switching Signal Device".
This output type is typically used with safety sensors and safety light curtains or for safe control outputs. Conventional
24 V DC outputs are actually critical for safety functions, as they cannot be detected by an external 24 V line via a
short circuit. For this reason, the two OSSD outputs are switched off with a time delay. During the pause time of the
output, a built-in input is activated and read back. If 24 V is present at the input after switching off the output, an
error is detected and the two built-in processors safely switch off both outputs.
This technology makes it easy to monitor short circuits and cross circuits up to PLe according to EN ISO 13849-1. With
the aid of an extended LED diagnosis, such as on the HOLDX R process guard locking or the RFID safety sensors of the
SAFIX, the detected faults on the safety sensor can be quickly detected and make troubleshooting considerably easier.
input 1 active
OSSD output 2
OSSD outpt 10,25 ms 8,5 ms 0,25 ms
U
t
t
U
input 2 active
K1 K2
0V
F1 F2
24V DC
RFID Sensor
24V DC
EDM
M
K1K2
K1K2 K1 K2
0V
F1 F2
24V DC
RFID Sensor
24V DC
EDM
M
K1K2
K1K2
Sicherheitsschaltgerät Sicherheitsschaltgerät
Aus Aus Ein Ein
OSSD outputs
22
Safety inputs
HOLDX R connector
CAN
Safety outputs
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Safety sensorcoded
Magnet
Anchor plate
Actuator
OSS
D1
OU
T
OSS
D2
OU
T
CAN
H
CAN
L
1
GN
D
3 2 4 7 85 6
120 R
1
X2
X1
GN
D
3 2 4
CAN
7 85 6
HOLDX RSlave
Safety inputs CAN
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Magnet
Dat
en
Cloc
k
1
GN
D
3 2 4 7 85 6
1
X2
X1
GN
D
3 5 6
HOLDX RMaster
Safety relais Safety PLC
Safety outputs
OSS
D1
OU
T
OSS
D2
OU
T
7 8 2 4
Diagnose OUT
Dat
en
Cloc
k
Safety PLCdiagnosis
Safety sensorcoded
Anchor plate
Actuator
Error GateLock
Error GateLock
Diagnose IN
Electrical connection
HOLDX R master slave series connection 8-pin
23
K1
K1
K2K2
Safety inputs
HOLDX R connector
CAN
Safety outputs
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Safety sensorcoded
Magnet
Anchor plate
Actuator
OSS
D1
OU
T
OSS
D2
OU
T
CAN
H
CAN
L
1
GN
D
3 2 4 7 85 6
120 R
1
X2
X1
GN
D
3 2 4
CAN
7 85 6
HOLDX RSlave
Safety inputs CAN
Safety outputs
CAN
H
CAN
L
OSS
D2
IN
OSS
D1
IN
+24
V D
C+2
4 V
DC
Magnet
OSS
D1
OU
T
OSS
D2
OU
T
Dat
en
Cloc
k
1
GN
D
3 2 4 7 85 6
1
X2
X1
24 V
0 V
GN
D
3 7 8
Diagnose IN
2 45 6
Diagnose OUT
Dat
en
Cloc
k
24 V
0 V
Safety sensorcoded
Anchor plate
Actuator
Safety PLCdiagnosis
Error GateLock
LED-Diagnose
LED-Diagnose
Error GateLock
EDM
109 11 12
HOLDX RMaster
Electrical connection
HOLDX R master slave series connection 12-pin with EDM function
24
DID YOU KNOW...that the Performace Level (PL) is reduced with a series connection of safety switches with mechanical contacts?
In order to save costs, safety switches of several safety doors are often connected in series to a safety relay. However,
the diagnostic capability of the faults is greatly reduced with a series connection of door switches with mechanical
contacts. This makes it difficult to determine the achievable performance level. This topic is described in EN ISO 14119
in paragraph "8.6 Logic series connection of interlocking devices" and reference is made to the technical report ISO/
TR 24119.
In the past, the same degree of diagnostic coverage (DC) was often incorrectly assumed for mechanical safety switches
with a series connection and a DC of 99% was specified by the manufacturer. However, in a series connection the
actual DC often shrinks below 60% and the achievable performance level of PLe drops to PLc.
For this reason, many machines are unnoticed equipped with an inadequate PL and are therefore not safe. According
to ISO/TR, these faults are referred to as fault concealment, but EN ISO 13849-1 requires for Cat. 3 or Cat. 4 that
every first fault is detected by the system and that the protective function is not impaired. For this reason, no category
3 can be claimed for these machines and the performance level PLe is not achieved, regardless of whether the DC
is above 60%.
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
Door 1 opened
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
All doors closed
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
Door 2 opened
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
Figure 1:
All doors are closed,
No error in the safety circuit,
Motor running
Figure 2:
All doors are closed,
Error in the safety circuit (cross circuit),
Fault due to safety relay not detected,
Motor running
25
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
Door 1 opened
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
All doors closed
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
Door 2 opened
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
Door 1 opened
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
All doors closed
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
K1 K2
F1 F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
24V 0V
0V
F1
Door 2 opened
K1 K2
F2
24V DC
24V DC
EDM
M
K1K2
K1K2
LED
Error in the safety circuit
contactor
Figure 3:
Door 1 opened,
Error in the safety circuit,
2-channel error is detected by the safety relay (only
one channel switches off),
Motor stopped
Figure 5:
Door 2 is opened
Error in the safety circuit,
Errors are cleared in the safety relay by opening both
channels,
Motor stopped
Figure 4:
All doors are closed,
Error in the safety circuit,
2-channel error is detected by the safety relay,
Motor stopped
Figure 6:
All doors are closed,
Error in the safety circuit,
But no error detected in the safety relay (error over-
written by opening both channels),
Motor running
26
The SAFIX 3 safety sensors and the HOLDX R process guard locking have safe OSSD outputs in the output circuit.
The use of OSSD outputs changes neither the wiring category nor the diagnostic coverage (DC) according to EN ISO
13849-1. Every single error that occurs is detected in the system and leads to a safe shutdown. Several safety switches
up to PLe can be connected in series without any problems.
If the safety sensors are cascaded (connected in series), only the PFHD value of the entire circuit must be calculated.
For the validation software SISTEMA libraries are available which can be downloaded from the SSP website.
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
0V
K1 K224V DC
M
K1K2
K1K2
24V
0V
4 73 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
24V DC
K1K2
24V
0V
4 7
3 1 5874
587
7
4
584
PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
5
2 6
2 6
4 7 5
54 7
2 6
M
K1K2
EIN
EIN
EIN
Aus
Aus
error
Aus
Aus
off
EIN
EIN
EIN
0V
K1 K2
The built-in EDM function monitors downstream, positively driven contactors. A safety relay is no longer necessary.
On
On
On
27
Error detection in the system thanks to the built-in OSSD outputs
Further information on page 21
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
0V
K1 K224V DC
M
K1K2
K1K2
24V
0V
4 73 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
OSSD output
24VD
C
0V
INFO outputED
M in
put
safety inputs
24V DC
K1K2
24V
0V
4 7
3 1 5874
587
7
4
584
PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
OSSD output
24VD
C
0V
INFO output
EDM
inpu
t
safety inputs
3 1PLC
5
2 6
2 6
4 7 5
54 7
2 6
M
K1K2
EIN
EIN
EIN
Aus
Aus
error
Aus
Aus
off
EIN
EIN
EIN
0V
K1 K2
Short circuit detected,
both outputs are switched off
If the safe inputs of the second sensor are
open, the safe outputs do not switch on.
The message output reports door closed
On
off
On
28
HOLDX S · The hybrid approach = All in one
Magnetic process guard locking HOLDX S1
Modern RFID sensor SAFIX HOLDX S1 process guard locking SAFIX and HOLDX combined
Magnetic power
500 N locking force
30 N permanent magnet
Secure electrical locking
In combination with SAFIX acc. To PLe EN ISO 13849-1
Smallest process guard locking
Mounting on aluminum profi le systems
Protection class
IP67
Connection
M12 8-pin
LED diagnosis
Extended status display in combination with SAFIX
Flexible
Movable anchor plate
SAFE POSITION MONITORING
The HOLDX S1 is equipped with both RFID sensors
SAFIX 1 and SAFIX 3 can be combined to
achieve a secure locking up to PLe according to
EN ISO 13849-1
29
Applications for HOLDX S1
HOLDX S1 HOLDX L1 movable anchor plate
Compact design and easy installation
LED diagnosis
Easy installation for various applications
The compact magnetic process guard locking HOLDX S1 with 500 N
locking force, protection class IP67 and easy installation is used every-
where where doors, hatches or drawers have to be locked.
The process guard locking HOLDX S1 provides an easy mounting
possibility for safety sensors. In combination with the non-contact
RFID sensor SAFIX, it enables a safe position monitoring (PLe acc.
to EN ISO 13849-1) with process guard locking. The process guard
locking HOLDX S1 opened in de-energized state can be installed with
a locking force of 500 N in almost all safety doors and openings. When
the magnetic clamp is unlocked, a 30 N permanent magnet provides
the fixation. Only an 8-pin cable is necessary for the connection of
the HOLDX S1, regardless of whether standalone or in combination
with SAFIX. In addition, with the safety distribution box XCONN, it is
possible to connect in series without great wiring effort.
The LED diagnosis is installed user-friendly next to the guard locking and
is visible from all areas. With the blue LED the operator can recognize
if the guard locking is locked.
30
Advantages of the XCONN passive junction
Connection of up to six SAFIX safety sensor with RFID technology
Connection of up to six HOLDX process guard lockings
Release of all process guard lockings can be set individually
Connection of up to six EDI emergency stop buttons
Simplify your installation and wiring effort
LED diagnosis
Extended status display
Type
Robust and compact
Connections
Plug connector M23 19-pin
fi xed cable connection 5 m and 10 m
Slots
Six connections via
Socket plug M12 8-pin
31
Extended LED diagnosis
Green
1x 2x
3x
4x
5x
Sensor state
Yellow 1x 2x
3x
4x
5xMagnet/EDM function triggering
Dimensioning
Brown
Blue
Yellow-Brown
Green-Yellow
White
Yellow
Pink
Grey-Brown
Green
Grey-Pink
White-Green
White-Yellow
White-Grey
Black
Purple
Red
Grey
Red-Blue
Supply voltage +24 V DC
Supply voltage 0 V DC
Input Magnet 1/Input EDM(Reset)
Input Magnet 2/Input EDM(Reset)
Input Magnet 3/Input EDM(Reset)
Input Magnet 4/Input EDM(Reset)
Input Magnet 5/Input EDM(Reset)
Input Magnet 6/Input EDM(Reset)
Diagnosis output sensor 1
Diagnosis output sensor 2
Diagnosis output sensor 3
Diagnosis output sensor 4
Diagnosis output sensor 5
Diagnosis output sensor 6
Safety input 1
Safety input 2
Safety input 1
Safety input 2
Electrical connection
32
Safe wireless distributors
Connections
Socket plug M12 8-pin
Networkable
Safe LED wireless or CAN interface
Protection class
IP65
4 shutdown circuits
Individually evaluable safety functions
Diagnosis
Extended LED diagnosis with touch panel
Voltage supply
Male connector M12 5-pin
Construction width
40 mm suitable for aluminum systems
X5
Safety in-/outputs
2 6 1 3 7 4 5
1X 2X 1A
I1 I2 I3 Q4
DSSO 2Y
DSSO 1Y
Info
EDM
12
SAFIX 3_-A-_ _
8
Mag
net E
IN
8
Mag
net E
IN
8ED
M
82 6 1 3 7 4 5
1X 2X 1A 2A2A
DSSO 2Y
DSSO 1Y
In
fo
12
SAFIX 3_-A-_ _
2 6 1 3 7 4 5
2X 1A 2A
DSSO 2Y
DSSO 1Y
In
fo
12
2 6 1 3 7 4 5
1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
Info
12
12
34
5
X6 X7 X8
X3
Safety in-/outputsI5 I6 I7
Safety in-/outputsI8 I9 I10 I11
Safety in-/outputsI12 I13 I14
The safe wireless distributors from SSP enable networking and decentralized
confi guration of up to 16 units acc. to PLe. Each safe distributor contains 14 safe
inputs/outputs, which can be fl exibly confi gured.
Further information can be found in our Safety Simplifi er catalog or at
www.safety-products.de
33
Decentralized safety conceptEach connection can be used individually or in combination with a safety function. With the free software "Simplifi er
Manager" the safety function can be programmed. The safe wireless distributors with the functions of the Safety
Simplifi er can take over the entire safety technology of your system. A higher-level safety control is not necessary.
X5
Safety in-/outputs
2 6 1 3 7 4 5
1X 2X 1A
I1 I2 I3 Q4
DSSO 2Y
DSSO 1Y
Info
EDM
12
SAFIX 3_-A-_ _
8
Mag
net E
IN
8
Mag
net E
IN
8
EDM
82 6 1 3 7 4 5
1X 2X 1A 2A2A
DSSO 2Y
DSSO 1Y
In
fo
12
SAFIX 3_-A-_ _
2 6 1 3 7 4 5
2X 1A 2A
DSSO 2Y
DSSO 1Y
In
fo
12
2 6 1 3 7 4 5
1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
Info
12
12
34
5
X6 X7 X8
X3
Safety in-/outputsI5 I6 I7
Safety in-/outputsI8 I9 I10 I11
Safety in-/outputsI12 I13 I14
Electrical connection
Control cabinet
34
Connection cables overview
Cable types
Cable type A connection line SAFIX 1
Cable type B connection line SAFIX 3, HOLDX S1 and HOLDX R_1
Cable type C connection line for M23 plug connection 19 pin
Cable type D connection line for M12 plug connection 5 pin for Safety Simplifi er
HOLDX RS1
Cable type A
Cable type B
Cable type B
Cable type B
Cable type B
Cable type C
SAFIX 3
XCONN P6-M12
SAFIX 1
HOLDX RL1
HOLDX S1 + SAFIX 3
A1
35
HOLDX RS1
Cable type A
Cable type B
Cable type B Cable type B
Cable type D
Cable type D
HOLDX RL1
36
Order listsSAFIX 3 - RFID safety sensor
Product image Denomination Coding EDM/reset Connection Item no.
SAFIX 3 - Sensors
SAFIX S3-A-P standard automatic pigtail M12 8-pin SP-E-76-000-01
SAFIX S3-X-P standard manual pigtail M12 8-pin SP-E-76-000-02
SAFIX W3-A-P relearnable high automatic pigtail M12 8-pin SP-E-76-000-05
SAFIX W3-X-P relearnable high manual pigtail M12 8-pin SP-E-76-000-06
SAFIX S3-A-10M standard automatic cable 10 m SP-E-76-000-08
SAFIX S3-X-10M standard manual cable 10 m SP-E-76-000-12
SAFIX W3-A-10M relearnable high automatic cable 10 m SP-E-76-000-24
SAFIX W3-X-10M relearnable high manual cable 10 m SP-E-76-000-28
SAFIX S3-A-5M standard automatic cable 5 m SP-E-76-000-10
SAFIX S3-X-5M standard manual cable 5 m SP-E-76-000-14
SAFIX W3-A-5M relearnable high automatic cable 5 m SP-E-76-000-26
SAFIX W3-X-5M relearnable high manual cable 5 m SP-E-76-000-30
SAFIX 3 kit - sensors incl. SAFIX T5 standard actuator
SAFIX SET I3-A-P individual high automatic pigtail M12 8-pin SP-E-76-000-33
SAFIX SET I3-X-P Individual high manual pigtail M12 8-pin SP-E-76-000-34
SAFIX SET I3-A-10M individual high automatic cable 10 m SP-E-76-000-46
SAFIX SET I3-X-10M individual high manual cable 10 m SP-E-76-000-50
SAFIX SET I3-A-5M individual high automatic cable 5 m SP-E-76-000-48
SAFIX SET I3-X-5M individual high manual cable 5 m SP-E-76-000-52
37
Product image Denomination Article information Item no.
SAFIX 3 - Actuator
SAFIX T5 standard actuator SP-E-76-000-00
SAFIX T6 fl at actuator SP-E-76-000-61
Product image Denomination Article information Item no.
SAFIX 3 - Equipment
SAFIX Z B5 installation kit for wing doors aluminum profi les, SAFIX (S, I, W) SP-K-71-000-08
SAFIX Z B6 installation kit for sliding doors aluminum profi les, SAFIX (S, I, W) SP-K-71-000-09
SAFIX Z-S12T screw kit 4 x M4x12 incl. torx bit T20H SP-E-76-000-11
Product image Denomination Length Article information Item no.
SAFIX 3 - Cable
C8D5 5 m M12 socket plug, 8-pin open end SP-R-13-309-80
C8D10 10 m M12 socket plug, 8-pin open end SP-R-13-309-81
C8D15 15 m M12 socket plug, 8-pin open end SP-R-13-309-82
C8D25 25 m M12 socket plug, 8-pin open end SP-R-13-309-67
C8D40 40 m M12 socket plug, 8-pin open end SP-R-13-309-66
Connecting cable for XCONN or Safety Simplifi er on Page 43
38
SAFIX 1 - RFID safety sensor
Product image Denomination Coding Connector Item no.
SAFIX 1 - Sensors
SAFIX S1 standard low male connector M8 8-pin SP-K-70-000-00
SAFIX I1 individual high male connector M8 8-pin SP-K-70-000-01
SAFIX W1 relearnable high male connector M8 8-pin SP-K-70-000-02
Product image Denomination Article information Item no.
SAFIX 1 - Actuator
SAFIX T3 standard actuator SP-K-70-000-03
SAFIX T4 fl at actuator SP-K-70-000-04
SAFIX 1 - Equipment
SAFIX Z S20 bolt kit M4 x 20, 4 items incl. washers SP-K-71-000-00
SAFIX Z S25 bolt kit M4 x 25, 4 items incl. washers SP-K-71-000-01
SAFIX Z D sealing kit, transparent SP-K-71-000-02
SAFIX Z M installation kit SP-K-71-000-03
SAFIX Z B5 installation kit for wing doors aluminum profi les, SAFIX (S, I, W) SP-K-71-000-08
SAFIX Z B6 installation kit for sliding doors aluminum profi les, SAFIX (S, I, W) SP-K-71-000-09
Product image Denomination Length Article information Item no.
SAFIX 1 - Cable
M8-C851-G 5 m M8 socket plug, 8-pin - straight to open end SP-X-33-000-00
M8-C8101-G 10 m M8 socket plug, 8-pin - straight to open end SP-X-33-000-01
M8-C8201-G 20 m M8 socket plug, 8-pin - straight to open end SP-X-33-000-02
M8-C851-V 5 m M8 socket plug, 8-pin - 90° to open end SP-X-33-000-03
M8-C8101-V 10 m M8 socket plug, 8-pin - 90° to open end SP-X-33-000-04
M8-C8201-V 20 m M8 socket plug, 8-pin - 90° to open end SP-X-33-000-05
Connecting cable for XCONN or Safety Simplifi er on Page 43
39
HOLDX R - smart process guard locking
Product image Denomination Locking force Coding Bluetooth Network Connection Item no.
HOLDX RS
RS1-P8-S 600 N standard 1 x pigtail 8-pin SP-X-71-001-00
RS1-P8-W 600 N individual 1 x pigtail 8-pin SP-X-71-001-01
RS1-P8-S-B 600 N standard 1 x pigtail 8-pin SP-X-71-001-04
RS1-P8-W-B 600 N individual 1 x pigtail 8-pin SP-X-71-001-05
RS1-P12-S 600 N standard 1 x pigtail 12-pin SP-X-71-001-16
RS1-P12-W 600 N individual 1 x pigtail 12-pin SP-X-71-001-17
RS1-P12-S-B 600 N standard 1 x pigtail 12-pin SP-X-71-001-20
RS1-P12-W-B 600 N individual 1 x pigtail 12-pin SP-X-71-001-21
RS2-CC-S 600 N standard slave 2 x pigtail 8-pin SP-X-71-001-08
RS2-CC-W 600 N individual slave 2 x pigtail 8-pin SP-X-71-001-09
RS2-CS-P8-S-B 600 N standard master 2 x pigtail 8-pin SP-X-71-001-10
RS2-CS-P8-W-B 600 N individual master 2 x pigtail 8-pin SP-X-71-001-11
RS2-CS-P12-S-B 600 N standard master 2 x pigtail - 8-pin/12-pin SP-X-71-001-24
RS2-CS-P12-W-B 600 N individual master 2 x pigtail - 8-pin/12-pin SP-X-71-001-25
HOLDX RL
RL1-P8-S 1200 N standard 1 x pigtail 8-pin SP-X-71-001-02
RL1-P8-W 1200 N individual 1 x pigtail 8-pin SP-X-71-001-03
RL1-P8-S-B 1200 N standard 1 x pigtail 8-pin SP-X-71-001-06
RL1-P8-W-B 1200 N individual 1 x pigtail 8-pin SP-X-71-001-07
RL1-P12-S 1200 N standard 1 x pigtail 12-pin SP-X-71-001-18
RL1-P12-W 1200 N individual 1 x pigtail 12-pin SP-X-71-001-19
RL1-P12-S-B 1200 N standard 1 x pigtail 12-pin SP-X-71-001-22
RL1-P12-W-B 1200 N individual 1 x pigtail 12-pin SP-X-71-001-23
RL2-CC-S 1200 N standard slave 2 x pigtail 8-pin SP-X-71-001-12
RL2-CC-W 1200 N individual slave 2 x pigtail 8-pin SP-X-71-001-13
RL2-CS-P8-S-B 1200 N standard master 2 x pigtail 8-pin SP-X-71-001-14
RL2-CS-P8-W-B 1200 N individual master 2 x pigtail 8-pin SP-X-71-001-15
RL2-CS-P12-S-B 1200 N standard master 2 x pigtail - 8-pin/12-pin SP-X-71-001-26
RL2-CS-P12-W-B 1200 N individual master 2 x pigtail - 8-pin/12-pin SP-X-71-001-27
40
Product image Denomination Article information Item no.
HOLDX RS anchor plate
HOLDX RS-A1 anchor plate with RFID tag - fi xed grid 50 N SP-X-71-001-42
HOLDX RS-A2 anchor plate with RFID Tag - no grid SP-X-71-001-43
HOLDX RL anchor plate
HOLDX RL-A1 anchor plate with RFID tag - fi xed grid 50 N SP-X-71-001-40
HOLDX RL-A2 anchor plate with RFID Tag - no grid SP-X-71-001-41
HOLDX R - equipment
HOLDX R1 connector plug 120 Ohm for HOLDX_R2 SP-X-71-002-06
HOLDX RL-Z-MF1 HOLDX RL installation kit wing doors SP-X-71-002-00
HOLDX RL-Z-MS1 HOLDX RL installation kit for sliding doors SP-X-71-002-01
HOLDX RS-Z-MF1 HOLDX RS installation kit for wing doors SP-X-71-002-02
HOLDX RS-Z-MS1 HOLDX RS installation kit for sliding doors SP-X-71-002-03
Product image Denomination Length Article information Item no.
HOLDX R_2 master/slave - connection cable
M12-M12-C-C8053-G 0.5 m M12 socket plug, 8-pole - M12 male connector SP-X-33-000-35
M12-M12-C-C813-G 1 m M12 socket plug, 8-pole - M12 male connector SP-X-33-000-36
M12-M12-C-C823-G 2 m M12 socket plug, 8-pole - M12 male connector SP-X-33-000-37
M12-M12-C-C853-G 5 m M12 socket plug, 8-pole - M12 male connector SP-X-33-000-38
M12-M12-C-C8103-G 10 m M12 socket plug, 8-pole - M12 male connector SP-X-33-000-39
HOLDX R Master - Cable
C8D5 5 m M12 socket plug, 8-pin open end SP-R-13-309-80
C8D10 10 m M12 socket plug, 8-pin open end SP-R-13-309-81
C8D15 15 m M12 socket plug, 8-pin open end SP-R-13-309-82
C8D25 25 m M12 socket plug, 8-pin open end SP-R-13-309-67
C8D40 40 m M12 socket plug, 8-pin open end SP-R-13-309-66
M12-C12101-G 10 m M12 socket plug, 12-pin open end SP-X-33-000-21
M12-C12201-G 20 m M12 socket plug, 12-pin open end SP-X-33-000-22
Connecting cable for XCONN or Safety Simplifi er on Page 43
41
HOLDX S1 - Magnetic process guard locking
Product image Denomination Article information Item no.
HOLDX S1 magnetic guard locking 500 Nm, M12 8-pin SP-X-73-000-00
Product image Denomination Coding EDM/reset Connection Connection line Item no.
HOLDX S1 kit - HOLDX S1 incl. SAFIX1, actuator T3, connecting cable M8-M12-C80153-VG, screw kit 4 x M4x16
HOLDX S1-S1 SET standard male connector M8 8-pin SP-X-73-000-05
HOLDX S1-W1 SET relearnable high male connector M8 8-pin SP-X-73-000-06
HOLDX S1-I1 SET individual high male connector M8 8-pin SP-X-73-000-07
HOLDX S1 Set - HOLDX S1 incl. SAFIX3, actuator T5, bolt kit 4 x M4x16
HOLDX S1-S3-A-P SET standard automatic pigtail M12 8-pin SP-X-73-000-51
HOLDX S1-W3-A-P SET relearnable high automatic pigtail M12 8-pin SP-X-73-000-52
HOLDX S1-I3-A-P SET individual high automatic pigtail M12 8-pin SP-X-73-000-53
Product image Denomination Article information Item no.
HOLDX S1 - equipment
HOLDX S1 distance kit change kit for reduced switching distance (SAFIX 3) SP-X-73-000-54
HOLDX S1-M0 installation kit sliding door SP-X-73-000-02
HOLDX S1-M2 installation kit wing door SP-X-73-000-04
Product image Denomination Length Article information Item no.
HOLDX S1 - Cable
C8D5 5 m M12 socket plug, 8-pin open end SP-R-13-309-80
C8D10 10 m M12 socket plug, 8-pin open end SP-R-13-309-81
C8D15 15 m M12 socket plug, 8-pin open end SP-R-13-309-82
C8D25 25 m M12 socket plug, 8-pin open end SP-R-13-309-67
C8D40 40 m M12 socket plug, 8-pin open end SP-R-13-309-66
Connecting cable for XCONN or Safety Simplifi er on Page 43
42
XCONN - Passive Distributor
Product image Denomination Article information Item no.
Passive distributor XCONN - 6 slots M12 8-pin
XCONN P6-M12-5m connector 5 m cable SP-X-71-000-00
XCONN P6-M12-10m connector 10 m cable SP-X-71-000-04
XCONN P6-M12-M23 connector M23 19-pin SP-X-71-000-01
XCONN - equipment
XCONN A1 jumper plug M12 8-pin SP-X-71-000-03
Safety Simplifi er - wireless distributor
Product image Denomination Article information Item no.
Wireless distributor Safety Simplifi er - 4 slots M12 5-pin
S14LDRB-H10-Q1A-Q2A-Q3C-Q4A-Q5I-Q6I-Q7I-Q8I-W34 SP-X-89-100-01
S16LDRB-H10-Q1A-Q2A-Q3A-Q4A SP-X-89-000-03
S14LDRB-H10-Q1A-Q2A-Q3A-Q4A SP-X-89-000-04
Simplifi er SRM Simplifi er radio monitor SP-N-88-850-03
Simplifi er ZMS Mounting plate small SP-N-88-850-01
Simplifi er ZMB Mounting plate large SP-N-88-850-02
Simplifi er ZSD Bolt with seal SP-N-88-001-89
43
Connection lines according to cable type p.34
Product image Denomination Length Article information Item no.
Cable (type A) connection line SAFIX 1
M8-M12-C8053-G 0.5 m M8 socket plug, 8-pin, - M12 male connector SP-X-33-000-13
M8-M12-C813-G 1 m M8 socket plug, 8-pin, - M12 male connector SP-X-33-000-14
M8-M12-C823-G 2 m M8 socket plug, 8-pin, - M12 male connector SP-X-33-000-15
M8-M12-C853-G 5 m M8 socket plug, 8-pin, - M12 male connector SP-X-33-000-16
M8-M12-C8103-G 10 m M8 socket plug, 8-pin, - M12 male connector SP-X-33-000-17
Cable (type B) connection line SAFIX 3, HOLDX S1 and HOLDX R_1
M12-M12-C823-G 2 m M12-socket plug, 8-pin - M12-male connector SP-X-33-000-07
M12-M12-C853-G 5 m M12-socket plug, 8-pin - M12-male connector SP-X-33-000-08
M12-M12-C8103-G 10 m M12-socket plug, 8-pin - M12-male connector SP-X-33-000-09
Cable (type C) connection line for M23 plug connection 19-pin
M23-C19101-G 10 m M23 socket plug, 19-pin - open end SP-X-33-000-19
M23-C19201-G 20 m M23 socket plug, 19-pin - open end SP-X-33-000-20
Cable (type D) connection line for M12 plug connection 5-pin for Safety Simplifier
CD5 5 m M12 socket plug, 5-pin - open end SP-R-13-309-50
CD10 10 m M12 socket plug, 5-pin - open end SP-R-13-309-56
CD20 20 m M12 socket plug, 5-pin - open end SP-R-12-100-32
44
Wiring examplesExample 1: Example 2:
RFID sensor SAFIX 1 with safety relay S series RFID sensor SAFIX 1 with safety PLC MOSAIC
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
13 23 33 41
14 24 34 42
K2
K1
A1 S33 S34 S35 13 23 33
A2 S21 S22 S12 S31 S11 14 24 34
TESER
34 44
12
Safety Relais S
Safety Relais E
Example 3: Series connection of RFID sensors SAFIX 1 with safety relay S series
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
13 23 33 41
14 24 34 42
K2
K1
A1 S33 S34 S35 13 23 33
A2 S21 S22 S12 S31 S11 14 24 34
TESER
34 44
1212
Safety Relais S
Safety Relais E
MOSAIC
24V DC
GND
5 2 6 1 3 7 4 8
13 23 33 41
14 24 34 42
K2
K1
24V DC IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 OUT1 OUT2 OUT3 OUT41 17 18 19 20 21 22 23 24 13 14 15 16
GND OSSD1A OSSD1B OSSD2A OSSD2B M-ENABLE 1 M-ENABLE 2 FBK1 FBK2 OUT ST 1 OUT ST 2
4 5 6 9 10 2 3 7 11 8 12
CLP/SPSTUO OFNI 1X 2X 1A 2A
1 DSSO 2Y2 DSSO 1Y
TESER
34 44
Safety Relais E
45
Example 5: Example 6:
RFID sensor SAFIX 3 with safety relay E series RFID sensor SAFIX 3 with safety PLC MOSAIC
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
ED
M
12
13 23 33 41
14 24 34 42
K2
B1 B3
B2 B4
K1
Safety Relays E
Example 7: Wiring concept SAFIX 3, HOLDX S1 & XCONN
X2.5 X2.6
X2.4
X2.2X2.1
X2.3
XCONN P6-M12-10m
SAFIX S3
A1 X1 A2 Y1 X2 Y2 EDM
INFO
OU
T
XCONN A1
XCONN A1 XCONN A1
XCONN A1
XCONN A1Cable Type (B)
18
X 1
X 1
X 2
X 2
Y 1
Y 1
Y 2
Y 2
A 2
A 2
EDM
IN A 1
A 1
27 36 45 54 63 72 81
HOLDX S1
MOSAIC
13 23 33 41
14 24 34 42
K2
K1
24V DC IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 OUT1 OUT2 OUT3 OUT41 17 18 19 20 21 22 23 24 13 14 15 16
GND OSSD1A OSSD1B OSSD2A OSSD2B M-ENABLE 1 M-ENABLE 2 FBK1 FBK2 OUT ST 1 OUT ST 2
4 5 6 9 10 2 3 7 11 8 12
TESER
34 44
Safety Relays E24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
O OFNI 1X 2X 1A 2A
DSSO 2Y
DSSO 1Y
ED
M
12
SAFIX _ _-A-_ _
46
Example 8: Series connection of two smart HOLDX R_1 process guard lockings with E series safety relays and manual reset
5 2 6 1 3 7 4 8
CLP/SP
S
CL P/SP
S
CL P/SP
S
TU
OOF
NI 1X 2X
1A
2A
DS
SO
2Y
DS
SO
1Y
129 10 11 12
13 23 33 41
14 24 34 42
K2
B1 B3
B2 B4
K1
Safety Relay E
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SP
ST
UO
OFNI 1
X 2X 1A
2A
DS
SO
2Y
DS
SO
1Y M
agne
t IN
Mag
net I
N
12
HOLDX RS1-P8-_-BHOLDX RL1-P8-_-B
HOLDX RS1-P12-_-BHOLDX RL1-P12-_-B
Manual ResetAutomatic Reset
Example 9: Smart process guard locking HOLDX R_1 with safety relay S series
CLP/ SPS
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
OOFNI 1X 2X 1A 2A
DSSO
2Y
DSSO
1Y Mag
net I
N
12
HOLDX RS1-P8-_-BHOLDX RL1-P8-_-B
Manual Reset
S21 S22 S12 S31 S11 14 24 34
S33 S34 S35 13 23 33A1
A2
Safety Relay S
Rese
t
13 23 33 41
14 24 34 42
K2
B1 B3
B2 B4
K1
Safety Relay E
47
Example 10: Smart process guard locking HOLDX R_1 with safety PLC MOSAIC
CLP/ SPS
24V DC
GND
5 2 6 1 3 7 4 8
CLP/SPSTU
OOFNI 1X 2X 1A 2A
DSSO
2Y
DSSO
1Y Mag
net I
N
12
HOLDX RS1-P8-_-BHOLDX RL1-P8-_-B
Manual Reset
MOSAIC
13 23 33 41
14 24 34 42
K2
K1
24V DC IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 OUT1 OUT2 OUT3 OUT41 17 18 19 20 21 22 23 24 13 14 15 16
GND OSSD1A OSSD1B OSSD2A OSSD2B M-ENABLE 1 M-ENABLE 2 FBK1 FBK2 OUT ST 1 OUT ST 2
4 5 6 9 10 2 3 7 11 8 12
TESER
3444
Safety Relay E
Example 11: Wiring concept HOLDX R_1 & XCONN
X2.5 X2.6
X2.4
X2.2
X1.1
X2.1
X2.3
XCONN P6-M12-M23XCONN P6-M12-M23
HOLDX R
Mag
net I
N
Cable Type (B)
XCONN A1
XCONN A1
XCONN A1
XCONN A1
XCONN A1
Cable Type (C)
SSP Safety System Products GmbH & Co. KG
Max-Planck-Straße 21 · 78549 Spaichingen · Germany
Tel. +49 7424 98049-0 · Fax +49 7424 98049-99
www.safety-products.de · [email protected]
INTERNATIONAL PARTNERS
Find them on our website
www.safety-products.de
Modifi cations and errors excepted July 2019