2
Backlit turned on by pressing button and shut off automatically if no operation done for 3 seconds Backlit Keep Lighting Backlit OFF This meter has an adjustable backlight: ON/OFF/AUTO, Default Backlit mode: AUTO (L-AUT). To Set the Backlit: On “TOT” total hours mode, Press “MENU” button 7 Times until display shows “L-AUT” (showed as chart below) , Hold the “MENU” button until “L-AUT” icon starts flashing, release and Press either “MENU”or “SET” button until you get your desired backlit mode. After 10 seconds with no operation done, the display will return to total hours, you are done. TOT=Total time of operation, Total time cannot reset to zero. Total time capacity: 99,999 Hours When engine is on, the dispaly will read RPM of engine. When engine is off, the display will switch to total running time and remains visible. Double-sided Tape(Included) Mount this unit with Double-sided Tape. Induction wire length: 1500MM / 4.9 feet. BACKLIGHT TOTAL TIME Product Installation Tach/Maintenance/Hour Meter Wiring Diagram Specifications Features Programmable Backlight:ON/OFF/AUTO. 8 Programmable Firing Patterns. Programmable Maintenance Interval Timer (0~200 Hours). Programmable RPM alert. Max RPM Recall. Internal Replaceable CR2032 battery & No external power required. Data retained after battery change. Works on 4 Stroke up to 16 cylinder/2 stroke up to 6 cylinder gas engines. Resettable for Job Time and Non-ressettable for Total Time. Battery level indicator. ON/OFF Switch. Hours Capacity: 99,999 Hours Hours Resolution: 0.1/1 hour RPM Capacity: Max 20,000 RPM RPM accuracy: 10 RPM Operating Temperature: Standard -10°C to +60°C Internal Battery: CR2032 and replaceable IP Rating: IP65 Programmable RPM Refresh Rate: 0.5S/1S Product Size Wrap Induction Wire 5-6 Turns TIGHTLY Around the SPARK PLUG WIRE No Ground Wire Required The induction wire can be cut off to shorten the length and can also be attached another wire to extend the length (Max100m/328 ft.), any common insulated wire is fine. It will not affect the operation If the signal is not strong enough, you can add one wrap at a time until the signal is clear. The signal strength is controlled by the number of wraps (Too many wraps will pick up electronic noise and give a faulty reading). 3 2 NOTICE: For 4 Stroke Gas Engines or Engines with “Pencil Coil” Ignition, Wrap Induction Wire Around the Plastic Coil Above the Spark Plug. 1 OPERATION INSTRUCTIONS “AUTO” mode “ON” mode “OFF” mode Self-Powered

Self-Powered Wiring Diagram Tach/Maintenance/Hour Meter

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Self-Powered Wiring Diagram Tach/Maintenance/Hour Meter

Backlit turned on by pressingbutton and shut off automaticallyif no operation done for 3 seconds

Backlit Keep Lighting

Backlit OFF

This meter has an adjustable backlight: ON/OFF/AUTO, Default Backlit mode: AUTO (L-AUT). To Set the Backlit: On “TOT” total hours mode, Press “MENU” button 7 Times until display shows “L-AUT” (showed as chart below), Hold the “MENU” button until “L-AUT” icon starts flashing, releaseand Press either “MENU”or “SET” button until you get your desired backlit mode. After 10 seconds with no operation done, the display will return to total hours, you are done.

TOT=Total time of operation, Total time cannot reset to zero.Total time capacity: 99,999 Hours

When engine is on, the dispaly will read RPM of engine. When engine is off, the display willswitch to total running time and remains visible.

Double-sided Tape(Included)

Mount this unit with Double-sided Tape.

Induction wire length: 1500MM / 4.9 feet.

BACKLIGHT

TOTAL TIMEProduct Installation

Tach/Maintenance/Hour Meter

Wiring Diagram

Specifications

FeaturesProgrammable Backlight:ON/OFF/AUTO.8 Programmable Firing Patterns.Programmable Maintenance Interval Timer (0~200 Hours).Programmable RPM alert.Max RPM Recall.Internal Replaceable CR2032 battery & No external power required.Data retained after battery change.Works on 4 Stroke up to 16 cylinder/2 stroke up to 6 cylinder gas engines.Resettable for Job Time and Non-ressettable for Total Time.Battery level indicator.ON/OFF Switch.

Hours Capacity: 99,999 HoursHours Resolution: 0.1/1 hourRPM Capacity: Max 20,000 RPMRPM accuracy: 10 RPMOperating Temperature: Standard -10°C to +60°CInternal Battery: CR2032 and replaceableIP Rating: IP65Programmable RPM Refresh Rate: 0.5S/1S

Product Size

Wrap Induction Wire 5-6 Turns TIGHTLY Around the SPARK PLUG WIRE

No Ground Wire Required

The induction wire can be cut off to shorten the length and can also be attached another wire to extend the length (Max100m/328 ft.), any common insulated wire is fine. It will not affect the operation

If the signal is not strong enough, you can add one wrap at a time until the signal is clear. The signal strength is controlled by the number of wraps (Too many wraps will pick up electronic noise and give a faulty reading).

3

2

NOTICE: For 4 Stroke Gas Engines or Engines with “Pencil Coil” Ignition, Wrap Induction Wire Around the Plastic Coil Above the Spark Plug.

1

OPERATION INSTRUCTIONS

“AUTO” mode “ON” mode “OFF” mode

Self-Powered

Page 2: Self-Powered Wiring Diagram Tach/Maintenance/Hour Meter

On “TOT” total hours mode, Press and Hold “MENU+SET” button Simultaneously until display shows “OFF”, release the button, Meter will be turned off. Press either “MENU” or “SET” button, Meter will be turned on.

To Adjust RPM Refresh Rate: Press and hold “MENU” button until default RPM refresh rate (0.5) starts flashing, release and press either “MENU” or “SET” button once, refresh rate will switch to 1S Release the button and wait for 10 seconds, the display will return to total hours, you are done.

RPM Refresh Rate = RPM Sampling TimeDefault RPM Refresh Rate: 0.5 SecondProgrammable RPM refresh Rate: 0.5 second / 1 second

To View RPM Refresh Rate: Press “MENU” button 6 Times

(Remark )

REMARK:

The correspondence between engine type and engine firing pattern, See form below for reference

8000

2000010000

16500

4000

6000

12000

20000

2 Stroke 6 Cylinder

4 Stroke 1 Cylinder

4 Stroke 5 Cylinder

4 Stroke 3 Cylinder

4 Stroke 12 Cylinder2 Stroke 4 Cylinder4 Stroke 8 Cylinder2 Stroke 3 Cylinder4 Stroke 6 Cylinder2 Stroke 2 Cylinder4 Stroke 4 Cylinder2 Stroke 1 Cylinder4 Stroke 2 Cylinder

5P2R 5 Sparks Per 2 Revolution

3P2R 3 Sparks Per 2 Revolution

6P1R 6 Sparks Per Revolution

4P1R 4 Sparks Per Revolution

3P1R 3 Sparks Per Revolution

2P1R 2 Sparks Per Revolution

1P1R 1 Spark Per Revolution

2

1

1 The actual firing pattern for a portion of 4 stroke 1 cylinder engine is 1 Spark Per Revolution, So you should set the firing pattern to 1P1R instead of 1P2R. Most single cylinder air cooled engines idle around 1400 RPM, if the RPM displayed too low, Set the firing pattern to 1P2R; If the RPM is too high, set more sparks per revolution, such as 2P1R, 3P1R...

1P2R / 1P1R

To Set Engine Firing Pattern: Press and Hold “MENU” button until default firing pattern“1P1R” starts flashing, release and press either “MENU” or “SET” button, the LCD will display 1P1R 1P2R2P1R 3P1R 3P2R 4P1R 5P2R and 6P1R separately. Once you find your desired Spark Plug firing pattern, release the button, the LCD will blink for 10 seconds and return to total hours, you are done.

1P1R means Spark Plug Fires ONCE PER REVOLUTION( Default Engine firing Pattern )

To View Engine Firing Pattern: Press “MENU” button 5 Times

Skip if RPM is correct, the default setting (1P1R) should work for most engines.Engine Firing Pattern = Spark Plug Firing Revolution

( Maximum RPM )

(Max RPM Reset)

To Reset Maximum RPM: Hold “MENU” until display shows “00000”, release the button, Max RPM will reset to zero.

To View Maximum RPM: Press “MENU” button 4 Times.Maximum RPM means Recorded Max RPM of last period of operation.

“ ”

(Default Alert RPM: 8500)

To Set RPM Alert: Press and hold “MENU” button until default Alert RPM (8500) starts flashing with GREEN backlit turning RED, release and press “MENU/SET” button to decrease/increase the RPM value (Hold the button, RPM value will decrease/increase 1000 units at a time). Stop at your desired RPM and wait for 10 seconds, the display will return to total hours with RED backlit returning to GREEN, you are done. When real-time RPM exceeds the programmable alert RPM, the icon and real-time RPM will flash to warn with RED backlit lighting.

To View RPM Alert Value: Press “MENU” button 3 Times.

SVC time has reached zero, the “SVC” icon will flash to warn.

Programmable SVC time: 0~200 HoursWhen SVC time =0, SVC timer will shut off.

Default SVC time: 20 HoursSVC Timer = Programmable Maintenance Interval Timer.

To Set SVC Time: Press and hold the “MENU” button until default SVC time(20H) starts flashing, release and press either “MENU” or “SET” button to decrease/increase the time. (Hold the button, hours will decrease/increase 10 units at a time)

Stop at your desired hours and wait for 10 seconds, the display will return to total hours. When

To View SVC Timer: Press “MENU” button Twice.

JOB time can reset to zero.

JOB hours reset to zero.

To View JOB Timer: Press the “MENU” button OnceTo Reset JOB Timer: Press and hold “MENU” button until display shows flashing “0000.0”, Release the button, JOB time will reset to 0.0 .

After 10 seconds with no operation done, the display will return to total hours (TOT), you will begin to record the next JOB interval.

JOB Time = Hours of operation since the timer was reset.

Maximum RPM

RPM ALERT

TURN OFF/ON

RPM Refresh Rate (Sampling Time)

SVC TIMER

ENGINE FIRING PATTERNJOB TIMER

Engine Firing Pattern Engine Type RPM Capacity