The 14 th World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China SEISMIC VIBRATION CONTROL OF A HIGH-RISE R.C. BUILDING BY A LARGE TUNED MASS DAMPER UTILIZING WHOLE WEIGHT OF THE TOP FLOOR A. Makino 1 , J. Imamiya 1 and N. Sahashi 1 1 Building Design Department, Nagoya Regional Branch, Takenaka Corporation, Nagoya, Japan Email: [email protected] ABSTRACT : This paper outlines the design of the high-rise R.C. building whose top floor is isolated and utilized as the mass of a large-scale mass damper, and describes the effect of the vibration control system realized by the design. In many cases, conventional mass dampers with additional weight on the building tops have been installed for the purpose of improving the habitability against strong wind. However, it has been rare for mass dampers to be used as countermeasures against earthquakes. We have developed a large-scale vibration control system utilizing the whole weight of building top floors to serve as mass dampers. The building used for our study on mass dampers is a high-rise R.C. structure, about 162 meters high at the highest point, with forty-three stories above the ground. Based on the seismic response analysis using the artificial earthquake waves, the natural vibration period of the mass damper was tuned so as to decrease the story drift of the whole building remarkably. If the building is assumed to be elastic, the optimum frequency of the mass damper is 3.8 sec., equivalent to the theoretically estimated from the primary natural frequency of the building. On the other hand, if the building is assumed to be elasto-plastic, the damper becomes the most effective when the frequency is tuned to about 8.0 sec. With the mass damper, the maximum story drift of the building is reduced by about 20%. KEYWORDS: Mass damper, Vibration control system, Seismic isolation, High-rise R.C. building 1. INTRODUCTION This paper outlines the design of the high-rise building whose top floor is isolated and utilized as the mass of a large-scale mass damper, and describes the effect of the vibration control system realized by the design. The building used for our study on mass dampers is a high-rise reinforced concrete structure, about 162 meters high at the highest point, with forty-three stories above the ground (refer to Figure 1). The lower part of the building from the first to the fourth floor, with plane area of about 100m×42m, houses a shopping mall, a life support center for the elderly people, and a broadcasting station. The high-rise part of the building from the fifth to the 42nd floor, with the plane area of about 37m×33m, has condominiums. There is a view lounge on the top floor, above which a helideck is located on the rooftop. There are seismic isolation floors underneath the view lounge and helideck, the weights of which are utilized for mass dampers. 2. STRUCTURAL OUTLINE Figure 2 shows the framing plan of the typical high-rise floors of the building. The framing work is in a pure rigid-frame RC structure, and the floors of the dwelling units are made of flat slabs (PC panel hybrid slabs). A double tube structure is used, where columns are intensively laid out along the perimeter and around the center core. The natural periods of the building are 3.7 sec. in the X direction, and 3.6 sec. in the Y direction respectively. 3. OUTLINE OF LARGE-SCALE MASS DAMPER

Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

SEISMIC VIBRATION CONTROL OF A HIGH-RISE R.C. BUILDING BY A LARGE TUNED MASS DAMPER UTILIZING WHOLE WEIGHT

OF THE TOP FLOOR

A. Makino1 , J. Imamiya

1 and N. Sahashi

1

1 Building Design Department, Nagoya Regional Branch, Takenaka Corporation, Nagoya, Japan

Email: [email protected] ABSTRACT : This paper outlines the design of the high-rise R.C. building whose top floor is isolated and utilized as the mass of a large-scale mass damper, and describes the effect of the vibration control system realized by the design. In many cases, conventional mass dampers with additional weight on the building tops have been installed for the purpose of improving the habitability against strong wind. However, it has been rare for mass dampers to be used as countermeasures against earthquakes. We have developed a large-scale vibration control system utilizing the whole weight of building top floors to serve as mass dampers. The building used for our study on mass dampers is a high-rise R.C. structure, about 162 meters high at the highest point, with forty-three stories above the ground. Based on the seismic response analysis using the artificial earthquake waves, the natural vibration period of the mass damper was tuned so as to decrease the story drift of the whole building remarkably. If the building is assumed to be elastic, the optimum frequency of the mass damper is 3.8 sec., equivalent to the theoretically estimated from the primary natural frequency of the building. On the other hand, if the building is assumed to be elasto-plastic, the damper becomes the most effective when the frequency is tuned to about 8.0 sec. With the mass damper, the maximum story drift of the building is reduced by about 20%. KEYWORDS: Mass damper, Vibration control system, Seismic isolation, High-rise R.C. building 1. INTRODUCTION This paper outlines the design of the high-rise building whose top floor is isolated and utilized as the mass of a large-scale mass damper, and describes the effect of the vibration control system realized by the design. The building used for our study on mass dampers is a high-rise reinforced concrete structure, about 162 meters high at the highest point, with forty-three stories above the ground (refer to Figure 1). The lower part of the building from the first to the fourth floor, with plane area of about 100m×42m, houses a shopping mall, a life support center for the elderly people, and a broadcasting station. The high-rise part of the building from the fifth to the 42nd floor, with the plane area of about 37m×33m, has condominiums. There is a view lounge on the top floor, above which a helideck is located on the rooftop. There are seismic isolation floors underneath the view lounge and helideck, the weights of which are utilized for mass dampers. 2. STRUCTURAL OUTLINE Figure 2 shows the framing plan of the typical high-rise floors of the building. The framing work is in a pure rigid-frame RC structure, and the floors of the dwelling units are made of flat slabs (PC panel hybrid slabs). A double tube structure is used, where columns are intensively laid out along the perimeter and around the center core. The natural periods of the building are 3.7 sec. in the X direction, and 3.6 sec. in the Y direction respectively. 3. OUTLINE OF LARGE-SCALE MASS DAMPER

Page 2: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

Figure 3 and Figure 4 show the floor plan of the view lounge and the cross section of the mass damper, respectively. The view lounge and helideck are individually base-isolated, which forms a dual structure of seismic isolation. The weight of the view lounge accounts for about 2.2% of the building weight above the ground, and the weight of the helideck accounts for about 0.2%. The operational stroke of the mass dampers is ±one meter. The larger mass and longer operational stroke than those of the conventional mass dampers against wind enable the system to work effectively against large earthquakes. As a part of the residential area, the view lounge (19,071kN in weight) is usually fixed to the main building, but if a strong earthquake hits the building, the lounge will be released to operate as a mass damper system. The automatic control system to operate the view lounge as a mass damper is as follows: The view lounge fixed will be automatically released by the signals of 80cm/s2 or more from the sensor installed on the first floor of the building. The helideck (1,862kN in weight), which is not a part of the residential area, is always in service as the measure against more moderate earthquakes.

Condominium

Isolation floor

View lounge

Helideck ▼43FL

▼5FL

▼162.8m

Figure 1 Building section

Double tube structure

7m

7m

7m

7m

28m

3 8m 8m 8m 8m Flat slab

Figure 2 Framing plan of typical floor

Condominium

Isolation floor for view

C(F

Helideck1,862kN

EV machine

Expansion joint, one meter long

View lounge19,071kN

Isolation floor for helideck

Helideck above

Expansion joint, one meter long

Core (Fixed)

View lounge (Operated)

Figure 4 Cross section of maFigure 3 Floor plan of view lounge

ore ixed)

2m

lounge

ss damper

Page 3: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

4. OUTLINE OF ISOLATION SYSTEM Figure 5 shows the plan of the isolation floor for the view lounge. The isolation system under the view lounge consists of the following 5 elements: 1. Sixteen (16) sheets of steel ball bearing panels to serve as a supporting element; 2. Eight (8) isolators of laminated rubber bearings, each piled up double to serve as a restoring element; 3. Eight (8) oil dampers to serve as a damping element; 4. Eight (8) oil dampers to control the view lounge floor; and 5. Eight (8) oil buffers to protect against collisions at velocities up to 60cm/s.

Steel ball bearing panel: 16 sheets

● Supporting element

● Damping and control element

● Restoring elementBase-isolator of laminated rubber bearing: 8 pieces

Oil damper for dumping: 8 pieces+ Oil damper for control: 8 pieces

Core(Fixed)

View lounge floor above

● Protection against collision

Oil buffer: 8 pieces

Figure 5 Floor plan of view lounge As the operational stroke of the mass dampers in this system is set to ±one meter, longer than that of the conventional mass dampers against wind, we have developed a long-stroke oil damper that can follow large displacements [1]. The rubber bearings are used only as a restoring element: Each isolator consists of two piled-up bearings for longer stroke. The exterior walls are controlled, synchronized with the view lounge floor: They are normally fixed to resist the strong wind, but the locked condition will be automatically released in a large earthquake. Table 1 shows the restoring force characteristics and dumping characteristics of the seismic isolation floor under the view lounge. Their natural vibration periods, 8.05 sec. for the view lounge floor and 4.9 sec. for the helideck floor, are set to achieve the maximum damping effect based on the preliminary response analysis. As shown in Figure 6 the damping factor of the oil dampers is proportional to the square of the velocity. The factor becomes closer to the theoretically optimum damping factor of a mass damper in a low velocity region, but increases in a high velocity region to control the maximum stroke of the damper.

Page 4: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

0

200

400

600

800

0 20 40 60 80 100 120

▼ Maximum load

High

Low

Velocity(cm/s2) Figure 6 Damping factor of the oil damper

1000

Table 1 Characteristics of seismic isolation floors under view lounge and helideck

Load

(kN

) View lounge HelideckWeight (kN) 19,071 1,862 Natural vibration period (sec.) 8.05

Coefficient of viscous damping (kN・s2/cm2)

0.42 0.10

4.90

5. SEISMIC RESPONSE ANALYSIS 5.1. Outline of analytical modeling and earthquake wave inputs Figure 7 shows the building model for the seismic response analysis. We prepared a flexure-shear model of point masses to analyze the main building, and used an elasto-plastic model to analyze the restoring force characteristics of the building. The seismic isolation floors were modeled so as to be subject to torsional vibration. Table 2 shows the maximum acceleration and maximum velocity of the earthquake waves used for the response analysis. We used two levels of artificial seismic waves to simulate the moderate and large-scale earthquakes, according to the acceleration response spectra on the engineering bedrock given by the Building Standard Law of Japan (refer to Figure 8), using the two phase characteristics. We made adjustment for moderate earthquakes: The acceleration of the input wave was set to such a level that the fixed view lounge floor starts to be released.

Table 2 Maximum Acceleration and Maximum Velocity ofEarthquakes Used for Response Analysis

Roof top of condominiumOil damper

Penthouse

View lounge floor

View lounge roof

Helideck

F)

Moderate earthquake

Large Earthquake Wave

No. Phase

Characteris-tics ACC

(cm/s2) VEL

(cm/s) ACC

(cm/s2)VEL

(cm/s)1 Random 80.0 7.1 586.3 49.9 2 Observed*1 80.0 5.7 607.8 57.4

*

Figure 7 Building model for seismic

response analysis

1 Observed in Kushir

Figure 8 Acceleratibedrock given by

(L

0

200

400

600

800

1000

0.01

Acc

eler

atio

n (c

m/s

2 )

▼ Relief load

o, Japan in 1993

on response spectra Building Standard arge Earthquake)

0.10 1.00Period (sec)

F=C・V2

on engineering Law of Japan

10.00

Page 5: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

5.2. Response of seismic isolation floor Table 3 shows the maximum response of the seismic isolation floor under the view lounge and their design criteria against large earthquakes. To satisfy the design criteria, the maximum inter-story displacement should not exceed 85cm, and the maximum inter-story velocity should not exceed 100cm/s. Figure 9 shows the graph of the literature-based critical accelerations of an overturning action of furniture [2]-[3], and we plotted the maximum acceleration of the view lounge floor in case of large earthquakes. As the natural frequencies are long, the acceleration levels are low enough to prevent an overturning action of three meter high furniture at the aspect ratio(H/B) of about 6.

0

100

200

300

400

500

0.0 0 1.5 2.0

▼Threshold frequency

Critical velocity Vcr=10B/√H

Hight=3meter

▼H/B=3.0

Critical accelerationAcr=B/H×g

Response

▼H/B=4.0 ▼ ▼H/B=6.0

Response Wave No.1

Wave No.2

Criteria

Displacement (cm) 62.3 68.5 85.0Velocity (cm/s) 87.2 93.6 100.0

Table 3 Maximum responses of seismic isolation floor under view lounge and their design criteria

Acc

eler

atio

n (c

m/s

2 )

Figure 9 Critic

overturning ac 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper on the X-directional intmoderate earthquake. The case of the mass damper remaining non-operationThe inter-story drift angle can be reduced by at maximum about 7%, if only tand by at maximum about 20% if the view lounge floor is also operating.

Inter-story displacement (x10-3rad), X-directional (a) Input Wave No.1 80cm/s2

Inter-story displac

0

5

10

15

20

25

30

35

40

45

0 0.2 0.4 0.6 0.8 1

View lounge & helideck fixed Helideck operational & View lounge fixed View lounge & helideck operational

0.0 0.2 0.4 0.6 0.8 1.0

42F40F

35F

30F

25F

20F

15F

10F

5F

1F0

5

10

15

20

25

30

35

40

45

0 0.20.0 0.2

42F40F

35F

30F

25F

20F

15F

10F

5F

1F

View lounHelideck oView loun

FloorFloor

(b) Input

Figure 10 Effect of mass damper on inter-story displacement (Mod

.5 1.0

Frequency (Hz) al acceleration of furniture tion vs. max. acceleration

er-story drift angle during a al is also shown in the charts. he helideck floor is operating,

ement (x10-3rad), X-directional0.4 0.6 0.8 10.4 0.6 0.8 1.0

ge & helideck fixed perational & View lounge fixed

ge & helideck operational

Wave No.2 80cm/s2

erate earthquake)

H/B=5.0

Page 6: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

5.4. Effect of mass damper in large earthquake Figure11 shows the effects of the mass damper with different natural periods on the X-directional inter-story drift angle during a large earthquake. The effect of the mass damper on the response varies considerably, according to the phase characteristics of earthquakes and the natural vibration periods of the mass damper.

Floor Floor

0

5

10

15

20

25

30

35

40

45

0 2 4 6 8 10

42F40F

35F

30F

25F

20F

15F

10F

5F

1F

0.0 2.0 4.0 6.0 8.0 10.0

Mass damper fixed T=3.8 sec. T=6.0 sec. T=8.0 sec.

0

5

10

15

20

25

30

35

40

45

0 2 4 6 8 10

Mass damper fixed T=3.8 sec. T=6.0 sec. T=8.0 sec.

42F40F

35F

30F

25F

20F

15F

10F

5F

1F

0.0 2.0 4.0 6.0 8.0 10.0

EInter-story displacement (x10-3rad), X-directional

Elasto-plastic analysis Inter-story displacement (x10-3rad), X-directional

(a) Input Wave No.1 586.3 cm/s2

Floor Floor

0

5

10

15

20

25

30

35

40

45

0 2 4 6 8 10

Mass damper fixed T=3.8 sec. T=6.0 sec. T=8.0 sec.

0

5

10

15

20

25

30

35

40

45

0 2 4 6 8 10

Mass damper fixed T=3.8 sec. T=6.0 sec. T=8.0 sec.

42F40F

35F

30F

25F

20F

15F

10F

5F

1F

42F40F

35F

30F

25F

20F

15F

10F

5F

1F

0.0 2.0 4.0 6.0 8.0 10.0 0.0 2.0 4.0 6.0 8.0 10.0

Inter-story displacement (x10-3rad), X-directional

E Inter-story displacement (x10-3rad), X-directional

Elasto-plastic analysis

Figu

lastic analysis

lastic analysis

(b) Input Wave No.2 607.8 cm/s2

re 11 Effect of mass damper on inter-story displacement (Large earthquake)

Page 7: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

In the analysis on an elastic building, the damper is the most effective when the natural vibration period of view lounge’s mass damper is set to 3.8 sec., that is equal to the optimum natural vibration period, theoretically estimated from the primary natural vibration period of the building. On the other hand, when the skeleton curve of the building is elasto-plastic, the natural vibration period of the damper will have to be as longer as about 8 sec. to attain a sufficient damping effect.

Also, as can be seen in the figures, the damping effects in an elasto-plastic building are not so good as those in an elastic building when the natural vibration periods are set to be optimum. In an elasto-plastic building, however, the responses still can be reduced by 20 - 40% at the floors with larger inter-story drift angles, and therefore the mass dampers are fully effective in practical use.

Moreover, the mass dampers with natural vibration periods of 6 and 8 sec., do not show any significant difference in damping effects. Therefore, no strict tuning is required for elasto-plastic buildings. 5.5. Fourier spectrum of response on building top Figure 12 shows the Fourier spectra of response waves on the building top (the lower side of the seismic isolation floor). In case of the elastic responses as shown by the solid lines below, the distinct peak in the natural vibration period disappears due to the mass damper effects. On the other hand, in case of the elasto-plastic responses as shown by the dashed lines, each spectrum has no distinct peak frequency, but the whole energy is increased in a longer period range than the elastic natural vibration period of the building. Accordingly, the mass dampers in an elasto-plastic building are also effective in reducing the energy not partially but throughout the long period range.

Four

ier s

pect

rum

(cm

/s)

1

1

Elastic Mass Fixed Elastic Damper T=3.8sec. Elasto-Plastic Mass Fixed

Elasto-Plastic Damper T=8.0sec.

,200

,000

800

600

400

200

0

0.0 2.0 4.0 6.0 8.0 10.0

Period (sec.)(a) Input Wave No.1 586.3 cm/s2

Figure 12(a) Fourier spectrum of response waves on building top(Large earthquake)

Page 8: Seismic Vibration Control of a High-Rise Roverturning action vs. max. acceleration 5.3. Effect of mass damper in modetate earthquake Figure 10 shows the effects of the mass damper

The 14th

World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China

Four

ier s

pect

rum

(cm

/s)

6

5

4

3

2

1

Elastic Mass Fixed Elastic Damper T=3.8sec. Elasto-Plastic Mass Fixed

Elasto-Plastic Damper T=8.0sec.

Fi 6. CONCLUSI The effect of a lis studied in telasto-plasticallof the mass damenable the massshould be set by REFERENCES [1] M. TakeucIdentification oArchitectural In[2] J. Milne (18Vol.3, Jan. to D[3] Y. Ishiyama317,July 1982,

00

00

00

00

00

00

0

0.0 2.0 4.0 6.0 8.0 10.0

Period (sec.)(

gure 12(b) Fourier

ON

arge mass damper uthis paper on the bay, the vibration of theper is not so remarka damper to be pract considering the nonl

hi and M. Yamamof Compression Rigstitute of Japan B-2, 81) Experiments in Oec. 1881, pp. 12-64

(1982) Criteria for Opp. 1-14

b) Input Wave No.2 607.8 cm/s2

spectrum of response waves on building top(Large earthquake)

ilizing the building top floor weight isolated from a high-rise R.C. building sis of the earthquake response analysis. As a R.C. structure behaves building is not simple natural frequency vibration. Accordingly, the effect ble as that on elastic vibration. However, sufficient mass and a long stroke ically effective enough. The natural vibration period of the mass damper inearity of the building appropriately.

to (2006), Performance Tests of Oil Damper with Long Stroke and idity of Damper, Summaries of Technical Papers of Annual Meeting September 2006, pp. 621-622. bservation Seismology, Transactions of the Seismological Society of Japan,

verturning of Bodies by Earthquake Excitations, Transaction of A.I.J., No.