Sdm Clarent

  • Upload
    ctditd

  • View
    231

  • Download
    1

Embed Size (px)

Citation preview

  • 8/19/2019 Sdm Clarent

    1/144

    NetPerformer®  SDM-9220/SDM-9230Hardware Installation Guide

  • 8/19/2019 Sdm Clarent

    2/144

    COPYRIGHTS AND DISCLAIMERS

    Published Date: May 10, 2013

    Document # 1588

    This publication contains information proprietary and confidential to Memotec Inc. Any reproduction,disclosure or unauthorized use of this publication is expressly prohibited except as Memotec Inc. mayotherwise authorize in writing.

    Memotec Inc. reserves the right to make changes without notice in product or component design as warranted by evolution in user needs or progress in engineering or manufacturing technology. Changes which affect theoperation of the unit will be documented in the next revision of the manual.

    We have made every effort to ensure the accuracy of the information presented in our documentation.However, Memotec assumes no responsibility for the accuracy of the information published. Productdocumentation is subject to change without notice. Changes, if any, will be incorporated in new editions ofthese documents. Memotec may make improvements or changes in the products or programs described within

    the documents at any time without notice. Mention of products or services not manufactured or sold byMemotec is for informational purposes only and constitutes neither an endorsement nor a recommendation forsuch products or services.

    Memotec Inc. is a wholly owned subsidiary of Comtech EF Data Corp., and its parent company ComtechTelecommunications Corp (NASDAQ: CMTL).

    CXTool, CX-U Series, CX-UA Series, AbisXpress, NetPerformer, AccessGate, SDM-8400, and the SDM-9000 series of products are either registered trademarks or trademarks of Memotec Inc.in Canada, the UnitedStates of America, and in other countries.

    Windows is a registered trademark of Microsoft Corporation in the United States and other countries.

    Any other trademarks are the property of their respective companies.

    Copyright © 2013 Memotec Inc.

    Memotec Inc.

    7755 Henri Bourassa Blvd. WestMontreal, QuebecCanada H4S 1P7Tel.: (514) 738-4781FAX: (514) 738-4436

    www.memotec.com

    http://www.memotec.com/http://www.memotec.com/

  • 8/19/2019 Sdm Clarent

    3/144

    Memotec Inc.

    Contents

    Chapter 1: Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

    1. 1 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    1.1.1 SDM-9220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    1.1.2 SDM-9230 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    1.1.3 Sales Contacts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

    1. 2 About this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

    1.2.1 Naming Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

    1.2.2 Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    1.2.3 Instructions to the Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    1.2.4 NetPerformer Document Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    1.2.5 Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

    1. 3 Changes to Console Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

    1. 4 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

    1.4.1 Providing Product Numbers to Technical Support . . . . . . . . . . . 1-8

    1.4.2 Providing Product Number to Technical Support . . . . . . . . . . . . 1-8

    1.4.3 Checking the Contents of Your Product Package . . . . . . . . . . . 1-8

    1.4.4 Returning a NetPerformer Unit. . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

    1. 5 Training and Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

    1.5.1 Request for Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

    1. 6 Notice Concerning HyperTerminal Connections . . . . . . . . . . . . . . . . . . . 1-10

    Chapter 2: Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    2. 1 Regulatory – Compliance and Agency Approval . . . . . . . . . . . . . . . . . . . . 2-2

    2. 2 Compliance and Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

    2.2.1 EU Directives 1999/5 and 2011/65. . . . . . . . . . . . . . . . . . . . . . . 2-3

    2.2.2 Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

    2.2.3 Intent of Use and Network Compatibility . . . . . . . . . . . . . . . . . . 2-6

    2.2.4 EN55022 and CISPR22 Statement . . . . . . . . . . . . . . . . . . . . . . 2-7

    2.2.5 FCC Part 15 Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8

    2.2.6 FCC Part 68 Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82.2.7 Connection to the Telephone Line . . . . . . . . . . . . . . . . . . . . . . . 2-8

    2.2.8 Problems, Repair and Warranty. . . . . . . . . . . . . . . . . . . . . . . . 2-10

    2.2.9 Industry Canada Statements . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

    2.2.10 The Ringer Equivalence Number (REN) . . . . . . . . . . . . . . . . . 2-11

    2.2.11 Notice d'Industrie Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

  • 8/19/2019 Sdm Clarent

    4/144

    Memotec Inc.

    2.2.12 Indice d’équivalence de la sonnerie (IES) . . . . . . . . . . . . . . . . 2-12

    2.2.13 Notice for Users in Australia – Emergency Dialing Warning . . 2-12

    2. 3 Environmental Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13

    2.3.1 Waste Electrical and Electronic Equipment – WEEE . . . . . . . 2-13

    2.3.2 Compliance to China RoHS. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14

    2. 4 Safety Warnings and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15

    2. 5 Making Changes or Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15

    Chapter 3: Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

    3. 1 About Unpacking the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

    3.1.1 Selecting a Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

    3.1.2 Size Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

    3.1.3 Distance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    3.1.4 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

    3. 2 Preparing the Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

    3.2.1 What You Will Need. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

    Chapter 4: Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

    4. 1 Chapter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    4. 2 Opening the Chassis Casing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3

    4. 3 Installing or Upgrading the DSP Module . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

    4.3.1 Removing a DSP Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7

    4. 4 Closing the Chassis Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-84. 5 Removing an Interface Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10

    4. 6 Hardware Strapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12

    4.6.1 NT/TE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12

    4.6.2 Setting the NT/TE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13

    4.6.3 E1-75 Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14

    4. 7 Installing an Interface Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18

    4. 8 Installing the Unit in a Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21

    4. 9 E&M Wiring and Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23

    4.9.1 E&M Grounding Considerations . . . . . . . . . . . . . . . . . . . . . . . 4-25

    4. 10 Installing the Ferrites (EMI Filters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26

    4. 11 Powering the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28

    4.11.1 SDM-9220 UAC or SDM-9230 UAC Unit Power Cords. . . . . . 4-28

    4.11.2 System Status on Power-up . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30

  • 8/19/2019 Sdm Clarent

    5/144

    Memotec Inc.

    4. 12 Connecting the Console Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32

    4.12.1 Important Console and Modem Settings for Startup . . . . . . . . 4-32

    4.12.2 Activating the Console Connection . . . . . . . . . . . . . . . . . . . . . 4-33

    4. 13 Installing the Licensed Software Options. . . . . . . . . . . . . . . . . . . . . . . . . 4-34

    4.13.1 Software License Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34

    4. 14 Connecting the LAN Hub. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35

    Chapter 5: Product Descript ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

    5. 1 SDM-9220/9230 Base Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

    5. 2 Optional Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    5. 3 Base Unit Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

    5.3.1 Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

    5.3.2 System Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

    5. 4 Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-65.4.1 Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

    5.4.2 LAN Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

    5.4.3 LAN Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7

    5. 5 Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8

    5.5.1 Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8

    5.5.2 Console Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8

    5. 6 Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9

    5.6.1 SDM-9220 UAC and SDM-9230 UAC . . . . . . . . . . . . . . . . . . . . 5-9

    5.6.2 SDM-9220 DC and SDM-9230 DC. . . . . . . . . . . . . . . . . . . . . . . 5-9

    5. 7 Rackmount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10

    5. 8 DSP Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11

    5.8.1 DSP-160 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11

    5.8.2 High-density DSP Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12

    5. 9 Interface Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13

    5.9.1 Analog Voice Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13

    5.9.2 Channelized Digital Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . 5-17

    5.9.3 Dual Serial Port (WAN) Interface . . . . . . . . . . . . . . . . . . . . . . . 5-22

    5.9.4 Interface Card Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23

    5.9.5 FXS and FXO Interface Cards . . . . . . . . . . . . . . . . . . . . . . . . . 5-26

    5.9.6 E&M Interface Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27

    5.9.7 T1/E1 and ISDN-BRI S/T Interface Cards . . . . . . . . . . . . . . . . 5-29

    5.9.8 Supporting E1-75 on a T1/E1 Port . . . . . . . . . . . . . . . . . . . . . . 5-30

  • 8/19/2019 Sdm Clarent

    6/144

    Memotec Inc.

    Chapter 6: Serial Port and User Equipment Connections. . . . . . . . . . . . . . . . . . . . . . . . . 6-1

    6. 1 Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2

    6. 2 Custom HD-26 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2

    6. 3 Connecting the User Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4

    6.3.1 Activating the User Equipment Connection . . . . . . . . . . . . . . . . 6-4

    6. 4 WAN/User Port Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5

    6. 5 Custom Serial Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6

    6.5.1 V.35/V.11 Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6

    6.5.2 TIA-232 (V.24) Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6

    6.5.3 X.21 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6

    6.5.4 X.21 EU Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7

    6.5.5 TIA-449 (V.36) Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7

    6.5.6 TIA-530 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7

    6. 6 Serial Port Connector and Custom HD-26 Cable Set Connectivity. . . . . . 6-8

    Chapter 7: Network ing Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

    7. 1 GSM A-bis/A-ter Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

    7. 2 Voice Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

    7. 3 Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    7. 4 Network Management and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    Chapter 8: Troubleshooting Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1

    8. 1 Symptoms, Problems, and Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2

    Chapter 9: Universal E&M/PTT Interface Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1

    9. 1 About the Universal E&M/PTT Interface Card. . . . . . . . . . . . . . . . . . . . . . 9-2

    9. 2 Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2

    9.2.1 Cable and Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2

    9. 3 About Push To Talk (PTT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5

    9.3.1 Fixed Control Station Scenario . . . . . . . . . . . . . . . . . . . . . . . . . 9-5

    9.3.2 Two Remote Locations Scenario. . . . . . . . . . . . . . . . . . . . . . . . 9-7

    9. 4 Configuring Push To Talk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8

    9.4.1 Configuring the E&M/PTT Physical Port (LINK) . . . . . . . . . . . . 9-8

    9.4.2 Configuring the E&M/PTT Channels (CHANNEL). . . . . . . . . . . 9-9

    Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index-1

  • 8/19/2019 Sdm Clarent

    7/144

    Memotec Inc.

    List of Figures

    Front View of the SDM-9220/9230 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

    Removing the Cover from the Unit Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4

    Location of Optional Hardware on the Main Board . . . . . . . . . . . . . . . . . . . . . . . 4-5

    Replacing the Cover onto the Unit Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9

    JP5 AND JP6 locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13

    Position of Jumper Connectors J4 and J7 on the Dual Port T1/E1 Interface Card . .4-15

    Location of Interface Cards in the SDM-9220/9230 Slots . . . . . . . . . . . . . . . . . .4-19

    Rackmount Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21

    Completed Rackmount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-22

    Four-wire E&M Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-24Two-wire E&M Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-24

    Installing a ferrite with an RJ-45/RJ-48 connector . . . . . . . . . . . . . . . . . . . . . . .4-27

    Power Cords for SDM-9220 UAC or SDM-9230 UAC Unit . . . . . . . . . . . . . . . . . . .4-28

    Harness and Wire for SDM-9220 DC or SDM-9230 DC Power Connection . . . . . . .4-29

    Rear View of the SDM-9230 UAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

    SDM-9220/9230 Installed with rackmount brackets . . . . . . . . . . . . . . . . . . . . . .5-10

    DSP-160 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-11

    High-density DSP module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-12

    The Dual FXS interface card (top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14

    The Quad FXS interface card (bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14

    The Dual FXO interface card (top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-15

    The Quad FXO interface card (bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-15

    The E&M interface card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-16

    The Single Port T1/E1 interface card (top) . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-19

    The Dual Port T1/E1 interface card (bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . .5-19

    The ISDN-BRI S/T interface card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-21

    The Dual Serial port interface card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-23

    RJ-11 pinout (female jack) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-26

    RJ-45 pinout (female jack) for E&M interface card . . . . . . . . . . . . . . . . . . . . . . .5-28

  • 8/19/2019 Sdm Clarent

    8/144

    Memotec Inc.

    RJ-48 to E1-75 dual BNC adaptor cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31

    RJ-45 Pinout (female jack) for Universal E&M/PTT Interface Card . . . . . . . . . . . . . 9-3

    SETUP Command Paths in the CLI Tree for Push To Talk Support . . . . . . . . . . . . . 9-8

  • 8/19/2019 Sdm Clarent

    9/144

    Memotec Inc.

    List of Tables

    Compatible Telecom Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

    Jumper installation parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16

    E&M wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23

    SDM-9220/9230 ports requiring a ferrite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26

    Front Panel LED States During System Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31

    Basic features of the SDM-9220/9230 unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

    Optional Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    List of physical ports and their port numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    STATUS LED states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

     ALARM LED states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5RJ-45 pinout for Ethernet LAN port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7

    Status LED indicators on analog voice interface cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23

    Status LED indicators on channelized digital interface cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25

    RJ-45 pinout for E&M interface card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27

    RJ-48 pinout for single/dual port T1/E1 interface cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29

    RJ-48 pinout for ISDN-BRI S/T interface card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29

    Serial connector and NetPerformer custom HD-26 cable set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8

    Packetization of DSP packets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

    RJ-45 pinout for the Universal E&M/PTT interface card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3

    Push-To-Talk Application: Scenario 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6

    Push-To-Talk Application: Scenario 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7

  • 8/19/2019 Sdm Clarent

    10/144

    Memotec Inc.

  • 8/19/2019 Sdm Clarent

    11/144

    1

    Memotec Inc. 1-1

    Preface

  • 8/19/2019 Sdm Clarent

    12/144

    SDM-9220/9230 Hardware Installation Guide

    1-2 Memotec Inc.

    1.1 Product Overview

    1.1.1 SDM-9220

    The NetPerformer SDM-9220 is an entry-level standalone chassis designed for network

    convergence at the branch office level. It is a high speed, low cost, flexible and powerfulunit that supports 8 analog or BRI/ST digital voice connections in a multitude ofapplication scenarios.

    The SDM-9220 base unit has:

    • One serial port equipped with HD-26 female connector 

    • Two 10/100Base-T Ethernet ports (RJ45 connectors)

    • One console port

    • Two expansion slots

    • All UAC base units come equipped with universal AC power supply and a choice

    of 120 VAC North American or 240 VAC European power cord (must be speci-fied at time of ordering)

    • The –48VDC versions include a 6-foot wiring harness

    • A DB9F-DB9F console cable and 19-inch rackmount kit are also included in the product package

    • A custom cable (HD-26 male connector) is required for the serial port, availablefrom Memotec Inc. or your NetPerformer distributor.

    The basic software set provides support of PowerCell Voice and Data (including legacyuser data) and IP routing over Ethernet, serial or digital ports using PPP or Frame RelayRFC-1490. Optional software licenses can be procured for support of GSM, SkyPerformer

    satellite access and TCP Acceleration.

    1.1.2 SDM-9230

    The NetPerformer SDM-9230 is a standalone chassis designed for network convergence atthe branch office level. It is a high speed, low cost, flexible and powerful unit that supportsanalog/digital voice and data in a multitude of application scenarios. It is ideal for branchoffices that require support for up to 12 analog or 120 digital telephony channels.

    The SDM-9230 base unit has:

    • One serial port equipped with HD-26 female connector 

    • Two 10/100Base-T Ethernet ports (RJ45 connectors)• One console port

    • Three expansion slots for analog voice, digital (T1/E1) voice/data, BRI/ST voice/data and dual serial interface cards

  • 8/19/2019 Sdm Clarent

    13/144

      Preface

    Memotec Inc. 1-3

    • All UAC base units come equipped with universal AC power supply and a choiceof 120 VAC North American or 240 VAC European power cord (must be speci-fied at time of ordering)

    • The –48VDC versions include a 6-foot wiring harness

    • A DB9F-DB9F console cable and 19-inch rackmount kit are also included in the

     product package• A custom cable (HD-26 male connector) is required for the serial port, available

    from Memotec Inc. or your NetPerformer distributor.

    The basic software set provides support of PowerCell Voice and Data (including legacyuser data) and IP routing over Ethernet, serial or digital ports using PPP or Frame RelayRFC-1490. Optional software licenses can be procured for support of GSM, SkyPerformersatellite access, TCP Acceleration and ATM.

    1.1.3 Sales Contacts

    To order NetPerformer units, DSP modules, cables and optional parts, contact Memotec

    Inc. or your NetPerformer distributor. To contact Memotec Inc.:

    • Mail:

    Memotec Inc.

    7755 Henri Bourassa Blvd. WestMontreal, QuebecCanada H4S 1P7

    • Telephone: +1 (514) 738-4781 during regular business hours, EST (GMT-5:00)Fax: + (1) 514 738 4436

    • Web: http://www.memotec.com 

  • 8/19/2019 Sdm Clarent

    14/144

    SDM-9220/9230 Hardware Installation Guide

    1-4 Memotec Inc.

    1.2 About this Document

    This document, NetPerformer® SDM-9220/9230 Hardware Installation Guide, providesthe following information about the SDM-9220 and SDM-9230:

    • Regulatory compliance information (“Compliance Information” on page 2-1)

    • Unpacking instructions (“Unpacking” on page 3-1)• Product description (“Product Description” on page 5-1)

    • Hardware installation instructions (“Hardware Installation” on page 4-1)

    • Troubleshooting procedures (“Troubleshooting Tips” on page 8-1)

    • Serial port specifications and user equipment connection (“Serial Port and UserEquipment Connections” on page 6-1)

    • Networking features (“Networking Features” on page 7-1)

    • Notice concerning HyperTerminal connection (“Notice Concerning HyperTermi-nal Connections” on page 1-10).

    For information on configuring the NetPerformer, consult the NetPerformer ReferenceGuides. See the “NetPerformer Document Set” on page 1-5 for a list of other references.

    NOTE: All NetPerformer documents are available on the NetPerformer CompanionCD, which is included with your product package.

    CAUTION:: Al l documents on the NetPerformer Companion CD,

    including this guide, must be opened with Adobe™ Acrobat Reader,which is provided on the CD.

    If you open a NetPerformer document with an earlier version of Acrobat Reader, some ofthe text will not appear in its intended format. This can make the text difficult orimpossible to read correctly, especially from a printed copy.

    1.2.1 Naming Conventions

    In this document:

    • The notation SDM-9220/9230 denotes the SDM-9220 and SDM-9230 products.

    The product is identified on the front of the unit.

    • SDM-9220 products include the SDM-9220 UAC model and the SDM-9220 DCmodel.

    • SDM-9230 products include the SDM-9230 UAC model and the SDM-9230 DCmodel.

  • 8/19/2019 Sdm Clarent

    15/144

      Preface

    Memotec Inc. 1-5

    The model number is identified on the nameplate on the bottom of the unit.

    1.2.2 Audience

    This document is intended for use by NetPerformer system administrators as well astechnicians who are qualified to set up, configure and troubleshoot a NetPerformer

    Enterprise Network.Installation of NetPerformer hardware requires knowledge and proficiency in theconfiguration, operation, maintenance and security of all enterprise network elements inyour application. You should also have a thorough understanding of telecommunicationsand be familiar with the networking strategies and telephony solutions currently used byyour organization.

    1.2.3 Instruct ions to the Reader 

    Instructions to the reader include notes, cautions and warnings, which are distinguishedfrom the rest of the text by distinctive formatting and icons. Here is an example of each:

    NOTE: A note may contain a reference, tip or other information related to the subjectat hand. The content of a note is intended to be helpful or of interest to thereader.

    CAUTION: A caution contains an instruction that the reader mustfollow in order to prevent damage to equipment, network failure orloss of data.

    The content of a caution must be read carefully and explicit ly obeyed.

    WARNING: A warning contains an instruction that the reader mustfollow in order to prevent electrical shock, death or serious injury to personnel.The content of a warning must be read carefully and explicitly

    obeyed.

    1.2.4 NetPerformer Document Set

    For complete information on the NetPerformer, consult the following:

    • NetPerformer Reference Guides

    Includes detailed information on new generation NetPerformer features, menus,commands, parameters and statistics displays.

  • 8/19/2019 Sdm Clarent

    16/144

    SDM-9220/9230 Hardware Installation Guide

    1-6 Memotec Inc.

    • NetPerformer Hardware Installation Guides

    These documents describe the hardware specific to each NetPerformer product,including installable options, complete installation instructions and firmwaredownload procedures.

    • NetPerformer Release Bulletins

    These documents summarize the system specifications, software fixes andchanges, and post-production documentation changes for a particular NetPer-former release.

    • NetPerformer Network Design Guide

    Offers valuable tips on how to design a NetPerformer application for maximumefficiency, including an analysis of data and voice traffic throughput issues andthe impact of traffic flow. Provides examples of network setup and traffic meas-urement using various NetPerformer products.

    1.2.5 Related Documents

    All of the documents listed here are available on the NetPerformer Companion CD, whichis included with your product package (Part no. 520-0081-001; Ordering part no. 161-0692-001).

  • 8/19/2019 Sdm Clarent

    17/144

      Preface

    Memotec Inc. 1-7

    1.3 Changes to Console Operations

    The following change to console operations was made in NetPerformer firmware versionV9.2.0, and still applies to firmware version V10.1.X and higher. If you are familiar withearlier versions of the NetPerformer firmware, this change should be taken intoconsideration before you configure or manage the product.

    • The way you access the NetPerformer console has changed to allow for multipleuser profiles:

    CAUTION:: The default LOGIN is now ADMIN instead of ACT.

    NOTE: The default PASSWORD for this login remains SETUP.

    For full instructions on setting up user profiles, refer to the Quick Configuration module ofthe NetPerformer Reference Guides.

  • 8/19/2019 Sdm Clarent

    18/144

    SDM-9220/9230 Hardware Installation Guide

    1-8 Memotec Inc.

    1.4 Technical Support

    Memotec Technical Support is designed to meet your full range of support needs. From basic service to mission-critical support, we are committed to ensuring your success with NetPerformer products. By employing state-of-the-art products and the latest technologiesavailable, we provide some of the fastest, most efficient service in the industry.

    Our entire support organization is focused on complete customer satisfaction and providing immediate solutions to your business needs.

    You can contact Technical Support by calling or sending email to our helpdesk facilities:

    • Telephone: +1 (514) 738-4781 during regular business hours, EST (GMT-5:00)

    • Email: [email protected]

    Be prepared to provide the following information:

    • Your name

    • Company name

    • Your location• Telephone number 

    • Product serial number (see next section)

    • Product work order number (see next section)

    • Detailed problem description

    • Remote access to the troubled unit via Telnet or dial-up modem.

    1.4.1 Providing Product Numbers to Technical Support

    You may be requested to provide the product serial number and work order number whencommunicating with Technical Support.

    1.4.2 Providing Product Number to Technical Support

    The product serial number may be requested when communicating with NetPerformerTechnical Support. The serial number can be found on the rear of the unit. See “Rear Viewof the SDM-9230 UAC” on page 5-2.

    1.4.3 Checking the Contents of Your Product Package

    CAUTION:: As soon as you receive your NetPerformer product,check the carton and its contents for any sign of damage duringshipment. If there is any damage, contact the shipping agentimmediately.

    Before you install your NetPerformer product, verify the contents of the carton to ensure

    mailto:[email protected]:[email protected]

  • 8/19/2019 Sdm Clarent

    19/144

      Preface

    Memotec Inc. 1-9

    that you have received all the units, accessories, cables and optional hardware that youordered.

    NOTE: A summary of product items appears on “Product Description” on page 5-1.

    If any items are missing, or if you have any questions concerning your shipment, contactTechnical Support.

    1.4.4 Returning a NetPerformer Unit

    If you need to return a NetPerformer unit for any reason, you must ship it in the originalcarton using adequate shock insulation material. Failure to do so may void theequipment warranty. Consult the Warranty statements included with the product package.Contact Technical Support for RMA requirements.

    1.5 Training and Documentation

    We offer a variety of classes to reduce your learning curve and make your employeesmore productive. Students learn how to tailor NetPerformer products to meet their specific business requirements. Each course is developed and delivered by certified instructorswho have in-depth expertise and extensive technical training experience. Customizedcourses, tailored to meet your business needs, are also available.

    To learn more about our training services, email our education facilities [email protected].

    1.5.1 Request for Comments

    Our Technical Publications group welcomes your feedback. Please help us improve futurereleases of this document by sending us your comments and suggestions. You can sendemail to [email protected].

    mailto:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]

  • 8/19/2019 Sdm Clarent

    20/144

    SDM-9220/9230 Hardware Installation Guide

    1-10 Memotec Inc.

    1.6 Notice Concerning HyperTerminal Connections

    The HyperTerminal communications program comes with Microsoft Windows  products, and can be used for very basic NetPerformer console functions if no terminalemulation program is available.

    CAUTION:: HyperTerminal is not  recommended for adjusting the NetPerformer configuration or monitoring its operations. Known problems include the following:

    • The arrow keys cannot be used to view channel status on all slots

    • The console speed cannot be changed from the default 9600 bps after the consoleconnection is up and running

    • On some computers, the default Emulation setting of the HyperTerminal com-munications program can potentially cause problems for console operations.

    If you must use HyperTerminal for your console connection, you should change the Emulation setting from Auto detect  to ANSI, as follows:

    1. Access HyperTerminal using the Windows Start button and drop-down menus:

    Start > Programs > Accessories > Commun ications > HyperTerminal

    2. If you have already defined the connection to the NetPerformer console port, openthat connection:

    File > Open > your_filename.ht

    3. If you have not yet defined the connection to the NetPerformer console port, create anew connection:

    File > New Connection > your_filename

    4. Open the Properties window for the connection:

    File > Properties

    5. Click on the Settings tab to view the current value of the Emulation parameter.

    6. Select the value ANSI from the list box for the Emulation parameter.

    7. Click OK.

    NOTE: The above procedure does not resolve the problems with arrow key func-

    tionality or console speed, and should be considered a temporary solutiononly. You should procure a more robust terminal emulation software programfor configuration and monitoring purposes. Contact Technical Support if youneed further assistance.

  • 8/19/2019 Sdm Clarent

    21/144

    2

    Memotec Inc. 2-1

    Compliance Information

  • 8/19/2019 Sdm Clarent

    22/144

    SDM-9220/9230 Hardware Installation Guide

    2-2 Memotec Inc.

    2.1 Regulatory – Compliance and Agency Approval

    These products comply with or have obtained Regulatory Agency approval at least againstthe following standards:

    • EMC – Emission –

    Class B

    FCC Part 15

    EN55022:2010 (SDM-9220 UAC, SDM-9230 UAC) AS/NZS CISPR22

    • EMC – Immunity EN 55024:1998 + A1 + A2

    • Safety IEC 60950-1EN60950-1:2006 + A11, 1 and 12 (SDM-9220 UAC, SDM-9230UAC)IEC 60950-1:2005 + Amendment 1 (SDM-9220 UAC, SDM-9230 UAC)UL 60950-1CSA C22-2 N°60950-1

     AS/NZS 60950

    • Telecom – Digital FCC Part 68 + TIA-968-AIC CS-03 Issue 8 - Part 2 and Part 6

     AS/ACIF S016 AS/ACIF S031 AS/ACIF S038TBR 1 + TBR 2TBR 3TBR4TBR 12 + TBR 13NTR4

    • Telecom – Analog FCC Part 68 + TIA-968-A

    IC CS-03 Issue 8 - Part 1 AS/ACIF S002TBR 15 + TBR 17TBR 21

  • 8/19/2019 Sdm Clarent

    23/144

      Compliance Information

    Memotec Inc. 2-3

    2.2 Compliance and Regulatory Statements

    2.2.1 EU Directives 1999/5 and 2011/65

    DECLARATION OF CONFORMITY

    Wedeclare under our sole responsibility that the NetPerformer products:

    SDM-9220 and SDM-9230Consisting of Models SDM-9220 UAC and SDM-9230 UAC

    With interface cards:

    - SDM-92X0 Quad E&M (100-1092-502)- SDM-92X0 Dual BRI S/T (100-1097-501)- SDM-92X0 Quad FXS (100-1106-502)- SDM-92X0 Dual FXS (100-1106-503)- SDM-92X0 Quad FX0 (100-1107-503)- SDM-92X0 Dual FX0 (100-1107-504)- SDM-92X0 Dual Serial (100-1126-501)- SDM-92X0 Single T1/E1 (100-1111-501)- SDM-92X0 Dual T1/E1 (100-1111-502)

    With Cable:- RJ48 to Dual BNC (502-0458-001)

    to which this declaration relates, are in conformity with:

    1- All applicable essential requirements following the provisions of the EuropeanDirective 1999/5/EC.

    The conformity assessment procedure used for this declaration is the Annex II of the Directive.

    Product compliance has been demonstrated against the following standards:

    EN 55022 2010EN 55024 1998 + Amendments 1 and 2EN 60950-1 2006 + Amendments A11, A12 and A1EN 61000-3-2 2006 + Amendments1 and 2EN 61000-3-3 2008

    2- The European Directive 2011/65/EC (RoHS Recast)

    The technical file is kept at: Memotec Inc 7755 Blvd Henri Bourassa

    Montreal, Quebec H4S 1P7 

    Canada

    Montreal, 20 March 2013

    Claude RocrayVice President, Engineering  P/N 137-0022-075-F 

  • 8/19/2019 Sdm Clarent

    24/144

    SDM-9220/9230 Hardware Installation Guide

    2-4 Memotec Inc.

    • MEMOTEC vakuuttaa täten että NetPerformer SDM-9220/9230 UAC tyyppinenlaite on direktiivin 1999/5/EY, 2011/65/EY oleellisten vaatimusten ja sitä koske-vien direktiivin muiden ehtojen mukainen.

    • Hierbij verklaart MEMOTEC dat het toestel NetPerformer SDM-9220/9230 UACin overeenstemming is met de essentiële eisen en de andere relevante bepalin-gen van richtlijn 1999/5/EG, 2011/65/EG.

    • Par la présente MEMOTEC déclare que l'appareil NetPerformer SDM-9220/9230UAC est conforme aux exigences essentielles et aux autres dispositions perti-nentes de la directive 1999/5/CE, 2011/65/CE.

    • Härmed intygar MEMOTEC att denna NetPerformer SDM-9220/9230 UAC står Iöverensstämmelse med de väsentliga egenskapskrav och övriga relevantabestämmelser som framgår av direktiv 1999/5/EG, 2011/65/EG.

    • Undertegnede MEMOTEC erklærer herved, at følgende udstyr NetPerformerSDM-9220/9230 UAC overholder de væsentlige krav og øvrige relevante krav idirektiv 1999/5/EF, 2011/65/EF.

    • Hiermit erklärt MEMOTEC, dass sich dieses NetPerformer SDM-9220/9230 UAC

    in Übereinstimmung mit den grundlegenden Anforderungen und den anderenrelevanten Vorschriften der Richtlinie 1999/5/EG, 2011/65/EG befindet. (BMWi).

    •   ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ MEMOTEC ΔΗΛΩΝΕΙ ΟΤΙ NetPerformer SDM-9220/9230UAC ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ  ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ, 2011/65/EK.

    • Con la presente MEMOTEC dichiara che questo NetPerformer SDM-9220/9230UAC è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabi-lite dalla direttiva 1999/5/CE, 2011/65/CE.

    • Por medio de la presente MEMOTEC declara que el NetPerformer SDM-9220/9230 UAC cumple con los requisitos esenciales y cualesquiera otras disposicio-nes aplicables o exigibles de la Directiva 1999/5/CE, 2011/65/CE.

    • MEMOTEC declara que este NetPerformer SDM-9220/9230 UAC está conformecom os requisitos essenciais e outras disposições da Directiva 1999/5/CE, 2011/65/CE.

    • Hawnhekk, MEMOTEC, jiddikjara li dan NetPerformer SDM-9220/9230 UAC jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemmfid-Dirrettiva 1999/5/EC, 2011/65/EC.

    • Käesolevaga kinnitab MEMOTEC seadme NetPerformer SDM-9220/9230 UACvastavust direktiivi 1999/5/EÜ, 2011/65/EÜ põhinõuetele ja nimetatud direktiivisttulenevatele teistele asjakohastele sätetele.

    •  Alulírott, MEMOTEC nyilatkozom, hogy a NetPerformer SDM-9220/9230 UACmegfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC, 2011/65/ECirányelv egyéb elõírásainak.

    • MEMOTEC týmto vyhlasuje, že NetPerformer SDM-9220/9230 UAC spĺňazákladné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES, 2011/65/ES.

  • 8/19/2019 Sdm Clarent

    25/144

      Compliance Information

    Memotec Inc. 2-5

    • MEMOTEC tímto prohlašuje, že tento NetPerformer SDM-9220/9230 UAC je veshodě se základními požadavky a dalšími př íslušnými ustanoveními směrnice1999/5/ES, 2011/65/ES.

    • Šiuo MEMOTEC deklaruoja, kad šis NetPerformer SDM-9220/9230 UAC atitinkaesminius reikalavimus ir kitas 1999/5/EB, 2011/65/EB Direktyvos nuostatas.

    •  Ar šo MEMOTEC deklar ē, ka NetPerformer SDM-9220/9230 UAC atbilstDirekt ī vas 1999/5/EK, 2011/65/EK būtiskajām pras ī bām un citiem ar tosaist ī tajiem noteikumiem.

    • MEMOTEC izjavlja, da je ta NetPerformer SDM-9220/9230 UAC skladu z bistve-nimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES, 2011/65/ES.

    • Hér með lýsir MEMOTEC yfir því að NetPerformer SDM-9220/9230 UAC er ísamræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC,2011/65/EC.

    • Niniejszym MEMOTEC oświadcza, że NetPerformer SDM-9220/9230 UAC jestzgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowie-niami Dyrektywy 1999/5/EC, 2011/65/EC.

    • MEMOTEC erklærer herved at utstyret NetPerformer SDM-9220/9230 UAC er isamsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF, 2011/65/EF.

    • Noi MEMOTEC declar ăm că aparatul NetPerformer SDM-9220/9230 UAC este în conformitate cu cerinţ ele esenţ iale şi cu alte prevederi relevante ale HotărâriiGuvernuluinr.88/2003 şi Directivei 1999/5/EC, 2011/65/EC.

    • MEMOTEC декларирам на своя отговорност, че далекосъобщително устройство NetPerformer SDM-9220/9230 UAC съответства на съществените изисквания по 1999/5/EC, 2011/65/EC.

    2.2.2 MarkingBoth the SDM-9220 UAC and the SDM-9230 UAC bear the following CE mark:

  • 8/19/2019 Sdm Clarent

    26/144

    SDM-9220/9230 Hardware Installation Guide

    2-6 Memotec Inc.

    2.2.3 Intent of Use and Network Compatibil ity

    Item Compatible Telecom Services

    The SDM-9230 and SDM-9230 unit with the appropri-ate DTE cables

    This telecom Equipment is intended to be connected to thefollowing telecom services:

    • X.21, V.24, V.35 or V.36 Leased Circuits, in all the coun-tries listed below

    • Packet Switched Data offering X.21, V.24, V.35 or V.36physical interface, in all the countries listed below

    List of countries: Austria, Belgium, Bulgaria, Czech Republic,Cyprus, Denmark, Estonia, Finland, France, Germany,Greece, Hungary, Iceland, Republic of Ireland, Italy, Latvia,Lithuania, Luxemburg, Malta, Netherlands, Norway, Poland,Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,Switzerland, UK.

    With Interface Card P/N

    100-1126-001 or -501 (DualSerial)

    This telecom Equipment is intended to be connected to the

    following telecom services:• X.21, V.24, V.35 or V.36 Leased Circuits, in all the coun-

    tries listed below

    • Packet Switched Data offering X.21, V.24, V.35 or V.36physical interface, in all the countries listed below

    List of countries: Austria, Belgium, Bulgaria, Czech Republic,Cyprus, Denmark, Estonia, Finland, France, Germany,Greece, Hungary, Iceland, Republic of Ireland, Italy, Latvia,Lithuania, Luxemburg, Malta, Netherlands, Norway, Poland,Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,Switzerland, UK

    With Interface Cards P/N100-1111-001/002 or -501/502 (Single/Dual T1/E1-120)

    This telecom Equipment is intended to be connected to thefollowing telecom services:

    • ISDN Primary rate access at 2048 kbps in all the countrieslisted below

    • G.703 Leased circuits at 2048 kbps structured andunstructured, using 120 Ohm interface, in all the countrieslisted below

    List of countries: Austria, Belgium, Bulgaria, Czech Republic,Cyprus, Denmark, Estonia, Finland, France, Germany,Greece, Hungary, Iceland, Republic of Ireland, Italy, Latvia,Lithuania, Luxemburg, Malta, Netherlands, Norway, Poland,Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,Switzerland, UK.

    Table 2-1: Compatible Telecom Services

  • 8/19/2019 Sdm Clarent

    27/144

      Compliance Information

    Memotec Inc. 2-7

    2.2.4 EN55022 and CISPR22 Statement

    This is a Class B product.

    With Interface Cards P/N100-1111-001/002 or -501/502 (Single/Dual T1/E1)and with cable P/N 502-

    0458-001 (75 ohm)

    This telecom Equipment is intended to be connected to thefollowing telecom service:

    • G.703 Leased circuits at 2048 kbps unstructured, using 75Ohm interface, in UK

    With Interface Cards P/N100-1097-001 or -501(ISDN-BRI S/T)

    This telecom Equipment is intended to be connected to thefollowing telecom service:

    • ISDN Basic rate access in all the countries listed below

    List of countries: Austria, Belgium, Bulgaria, Czech Republic,Cyprus, Denmark, Estonia, Finland, France, Germany,Greece, Hungary, Iceland, Republic of Ireland, Italy, Latvia,Lithuania, Luxemburg, Malta, Netherlands, Norway, Poland,Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,Switzerland, UK.

    With Interface Cards P/N100-1107-003/004 or -503/504 (Quad/Dual FXO)

    This telecom Equipment is intended to be connected to thefollowing telecom service:

    • Analog access to PSTN, in all the countries listed below

    List of countries: Austria, Belgium, Bulgaria, Czech Republic,Cyprus, Denmark, Finland, France, Germany, Greece, Hun-gary, Iceland, Republic of Ireland, Italy, Latvia, Luxemburg,Netherlands, Norway, Poland, Portugal, Romania, Spain,Sweden, Switzerland, UK.

    With Interface Cards P/N100-1092-002 or -502(Quad E&M)

    This telecom Equipment is intended to be connected to thefollowing telecom services:

    • 2-wire Analog access to Leased Circuits in all the coun-tries listed below

    • 4-wire Analog access to Leased Circuits in all the coun-tries listed below

    List of countries: Austria, Belgium, Bulgaria, Czech Republic,Cyprus, Denmark, Estonia, Finland, France, Germany,Greece, Hungary, Iceland, Republic of Ireland, Italy, Latvia,Lithuania, Luxemburg, Malta, Netherlands, Norway, Poland,Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,Switzerland, UK.

    Item Compatible Telecom Services

    Table 2-1: Compatible Telecom Services

  • 8/19/2019 Sdm Clarent

    28/144

    SDM-9220/9230 Hardware Installation Guide

    2-8 Memotec Inc.

    2.2.5 FCC Part 15 Statement

    This digital equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to part 15 of the FCC Rules.

    These limits are designed to provide reasonable protection against harmful interference ina residential installation. This equipment generates, uses and can radiate radio frequency

    energy and, if not installed and used in accordance with the instructions, may causeharmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation.

    If this equipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is encouraged to try tocorrect the interference by one or more of the following measures:

    • Reorient or relocate the receiving antenna

    • Increase the separation between the equipment and receiver 

    • Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.

    2.2.6 FCC Part 68 Statement

    This equipment complies with Part 68 of the FCC rules and the requirement adopted byACTA of the United States.

    On the product nameplate of this equipment (located on the underside of the productchassis) is a label that contains, among other information, a product identifier in the formatUS:AAAEQ##TXXXX.

    If requested, this number must be provided to the telephone company.

    2.2.7 Connection to the Telephone Line• This equipment uses jacks for connection to the telephone line. You must, upon,

    request, provide the following “USOC Jack type” to your local telephone com- pany:

    - For equipment equipped with the interface card 100-1107-003/004, theUSOC jack type: RJ11C

    - For equipment equipped with the interface card 100-1111-001/002, the USOC jack type: RJ48C

    • This equipment cannot be used on the public coin phone service provided by thetelephone company. Connection to party line service is subject to state tariffs.

    • Your telephone company may discontinue your service if your equipment causesharm to the telephone network. They will notify you in advance of disconnection,if possible. During notification, you will be informed of your right to file a com- plaint to the FCC.

    • Occasionally, your telephone company may make changes in its facilities, equip-ment, operation, or procedures that could affect the operation of your equipment.

  • 8/19/2019 Sdm Clarent

    29/144

      Compliance Information

    Memotec Inc. 2-9

    If so, you will be given advance notice of the change to give you an opportunityto maintain uninterrupted service.

    • THE REGISTRATION NUMBER OF THE SYSTEM MUST BE PROVIDEDSO THAT THE TELEPHONE COMPANY CAN ASCERTAIN INTENDEDMODES OF OPERATION AND VERIFICATION OF REGISTRATIONPORTS.

    • If a need arises in the future, the telephone company will call the user and requestthe following information for any equipment being connected to the PublicSwitched Telephone Network:

    For equipment equipped with interface cards 100-1107-003/004 or-503/504 (Quad/Dual FXO):

    - Manufacturer: Memotec Inc.

    - Model Number: Refer to the nameplate on the bottom of the unit 

    - FCC Registration #: Refer to the nameplate (bottom of the unit)

    - Ringer Equivalence Number (REN):0.1B

    - Facility Interface Code (FIC): 04DU9-1SN 

    - Service Order Code (SOC): 6.0F 

    - Telephone plug: RJ11C 

    For equipment equipped with interface cards 100-1111-001/002 or –501/502(Dual/Single T1):

    - Manufacturer: Memotec Inc.

    - Model Number: Refer to the nameplate on the bottom of the unit 

    - FCC Registration #: Refer to the nameplate (bottom of the unit)

    - Ringer Equivalence Number (REN): Not applicable

    Facility Interface Code (FIC):

    04DU9-BN  for 1.544 Mbps, D4

    04DU9-DN  for 1.544 Mbps, D4 and B8ZS

    04DU9-1KN  for 1.544 Mbps, ANSI ESF

    04DU9-1SN  for 1.544 Mbps, ANSI ESF and B8ZS

    - Service Order Code (SOC): 6.0F 

    - Telephone plug: RJ48C 

  • 8/19/2019 Sdm Clarent

    30/144

    SDM-9220/9230 Hardware Installation Guide

    2-10 Memotec Inc.

    2.2.8 Problems, Repair and Warranty

    Should you experience trouble with this telephone equipment or for repair or warrantyinformation, please contact Memotec Inc. Canada, Inc. at +1 (514) 738-4781. If theequipment is causing harm to the telephone network, the telephone company may requestthat you disconnect this equipment from the line network until the problem has been

    corrected.

    Supplier’s DECLARATION OF CONFORMITY

    Wehereby certify that the following NetPerformers:

    SDM-9210Consisting of Models SDM-9210 UAC and SDM-9210 DC

    SDM-9220Consisting of Models SDM-9220 UAC and SDM-9220 DC

    SDM-9230Consisting of Models SDM-9230 UAC and SDM-9230 DC

    bearing labeling identification number US: 2PDDF01B009230 

    comply with the Federal Communications Commission’s (FCC) Rules and

    Regulations 47 CFR Part 68 , and the Administrative Council on TerminalAttachments (ACTA) adopted technical criteria TIA-968-A, Telecommunications –Telephone Terminal Equipment – Technical Requirements for Connection of TerminalEquipment to the Telephone Network, October 2002, TIA-968-A-1, TIA-968-A-2,TIA-968-A-3, TIA-968-A-4, TIA-968-A-5, and also comply with TIA-1096-A,Telecommunications – Telephone Terminal Equipment Connector Requirements forConnection of Terminal Equipment to the Telephone Network, March 2008.

    Montreal, 21 October 2008

    Stéphane CaronHardware Manager 

    137-0022-054 C

  • 8/19/2019 Sdm Clarent

    31/144

      Compliance Information

    Memotec Inc. 2-11

    2.2.9 Industry Canada Statements

    This digital equipment does not exceed Class B limits for radio noise emissions for digitalapparatus, set out in Radio Interference Regulation of the Industry Canada. Operation in aresidential area may cause unacceptable interference to radio and TV reception requiringthe owner or operator to take whatever steps necessary to correct the interference.

    This product meets the applicable Industry Canada technical specifications.The Industry Canada label identifies certified equipment. The certification means that theequipment meets certain telecommunications network protective, operations, and safetyrequirements as prescribed in the appropriate Terminal Equipment TechnicalRequirements document(s). The Industry Canada does not guarantee the equipment willoperate to the user's satisfaction.

    Before installing this equipment, users should ensure that it is permissible to be connectedto the facilities of the local telecommunications company. The equipment must also beinstalled using an acceptable method of connection. The customer should be aware thatcompliance with the above conditions may not prevent degradation of service in somesituations.

    Repairs to certified equipment should be made by a Memotec Inc. authorized maintenancefacility. Any repairs or alterations made by the user to this equipment, or equipmentmalfunctions, may give the telecommunications company cause to request the user todisconnect the equipment.

    Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, areconnected together. This precaution may be particularly important in rural areas.

    Users should not attempt to make such connections themselves, but should contactthe appropriate electric inspection authority, or electrician, as appropriate.

    2.2.10 The Ringer Equivalence Number (REN)

    The Ringer Equivalence Number assigned to each terminal device provides an indicationof the maximum number of terminals allowed to be connected to a telephone interface.The termination on an interface may consist of any combination of devices subject only tothe requirement that the sum of Ringer Equivalence Numbers of all the devices does notexceed 5.

    2.2.11 Notice d'Industrie Canada

    Cet équipement ne dépasse pas les limites de Classe B d'émission de bruits

    radioélectriques pour les appareils numériques, telles que prescrites par le Règlement surle brouillage radioélectrique établi par l’Industrie Canada. L'exploitation faite en milieurésidentiel peut entraîner le brouillage des réceptions de radio et de télévision, ce quiobligerait le propriétaire ou l'opérateur à prendre les dispositions nécessaires pour enéliminer les causes.

    Le présent matériel est conforme aux spécifications techniques applicables d’IndustrieCanada.

  • 8/19/2019 Sdm Clarent

    32/144

    SDM-9220/9230 Hardware Installation Guide

    2-12 Memotec Inc.

    L'étiquette d'industrie Canada identifie le matériel homologué. Cette étiquette certifie quele matériel est conforme aux normes de protection, d'exploitation et de sécurité desréseaux de télécommunications, comme le prescrivent les documents concernant lesexigences techniques relatives au matériel terminal. Le Ministère n'assure toutefois pasque le matériel fonctionnera à la satisfaction de l'utilisateur.

    Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder auxinstallations de l'entreprise locale de télécommunication. Le matériel doit également êtreinstallé en suivant une méthode acceptée de raccordement. L'abonné ne doit pas oublierqu'il est possible que la conformité aux conditions énoncées ci-dessus n'empêche pas ladégradation du service dans certaines situations.

    Les réparations de matériel homologué doivent être coordonnées par un représentantdésigné par Memotec Inc. L'entreprise de télécommunications peut demander àl'utilisateur de débrancher un appareil à la suite de réparations ou de modificationseffectuées par l'utilisateur ou à cause d’un mauvais fonctionnement.

    Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de lasource d'énergie électrique, des lignes téléphoniques et des canalisations d'eau

    métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est particulièrementimportante dans les régions rurales.

    L'utilisateur ne doit pas tenter de faire les raccordements lui-même, mais doit avoirrecours à un service d’inspection d’installations électriques ou d’un électricien.

    2.2.12 Indice d’équivalence de la sonnerie (IES)

    L'indice d'équivalence de la sonnerie assigné à chaque dispositif terminal indique lenombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaisond'une interface téléphonique peut consister en une combinaison de quelques dispositifs, àla seule condition que la somme d'indices d'équivalence de la sonnerie de tous les

    dispositifs n'excède pas 5.

    2.2.13 Notice for Users in Australia – Emergency Dialing Warning

    In the event of a power failure, an FXO interface card (Part No. 100-1107-003/004or -503/504) will not operate.

  • 8/19/2019 Sdm Clarent

    33/144

      Compliance Information

    Memotec Inc. 2-13

    2.3 Environmental Information

    2.3.1 Waste Electrical and Electronic Equipment – WEEE

    The WEEE (Waste Electrical and Electronic Equipment) legislation aims to raise the level

    of recycling of electrical and electronic equipment and to encourage designers to create products with recycling in mind.

    The NetPerformer equipment that you bought has required the extraction and use ofnatural resources for its production. It may contain hazardous substances that could impacthealth and the environment.

    In order to avoid the dissemination of those substances in our environment and to diminishthe pressure on the natural resources, we encourage you to use the appropriate take-backsystems. Those systems will reuse or recycle most of the materials of your end-of-lifeequipment in a sound way.

    The crossed-out wheeled bin symbol invites you not to dispose of WEEE as unsorted

    municipal waste and to collect such WEEE separately.If you need more information on the collection, reuse and recycling systems, pleasecontact your local or regional waste administration.

    You can also contact us for more information on the environmental performances of our products

  • 8/19/2019 Sdm Clarent

    34/144

    SDM-9220/9230 Hardware Installation Guide

    2-14 Memotec Inc.

    2.3.2 Compliance to China RoHS

  • 8/19/2019 Sdm Clarent

    35/144

      Compliance Information

    Memotec Inc. 2-15

    2.4 Safety Warnings and Precautions

    WARNING

    WARNUNG

    AVERTISSEMENT

    CAUTION: The ground lug is a main earth terminal that must be permanently connected

    to earth.VORSICHT: Die Erdungsöse ist einer der wichtigsten Erdungsklemme, die dauerhaft aufdie Erde angeschlossen werden muss.

    ATTENTION: La cosse de terre est une borne de terre principale qui doit être connectéeen permanence à la terre.

    2.5 Making Changes or Modifications

    Any changes and modifications not expressly approved by Memotec Inc. will voidany compliance and regulatory approval, and will void the user’s authority tooperate the equipment.

     Access to the interior of this unitshall be made only by a quali-fied technician.

    Der Zugang ins Innere des Gerätes istnur einem fachlich qualifizierten Tech-niker gestattet.

    Seul un spécialiste doit avoiraccès à l'appareil.

    Remove power plug from thepower socket before perform-ing any service on the unit.

    Vorm Ôffnen des Gerätes muss derNetzstecker yom Stromnetz getrenntwerden!

    Débranchez l'appareil avant del'ouvrir.

    To ensure adequate cooling ofthe equipment, a 2-inch unob-structed space must be pro-vided around all sides of theunit.

    Um die Kühlung des Gerätes nicht zubeeinträchtigen, ist es notwendig, anallen Seiten des Gerätes ca 5 cm Raumzu lassen.

     Afin de ne pas nuire au proces-sus de refroidissement, il estnécessaire de laisser un espaced'environ 5 cm de chaque côtéde l'appareil.

    The Power Socket shall beinstalled near the equipmentand shall be easily accessible.

    Stellen Sie das Gerät in der Nähe einesgeer- deten Schutzkontaktsteckers soauf, dass der Stecker leicht erreichbarund zugänglich ist.

    Placez l'appareil près d’uneprise de courant facilementaccessible.

    To prevent the risk of shock orfire hazard, replace fuse withsame type and rating.

    Zür Vermeidung der Stromschlag-undFeuergefahr beim Auswechseln Sicher-ungen des gleichen Typs und der glei-chen Nennleistung einsetzen.

     Afin d’éviter tout risqued’incendie ou d’électrocution,remplacez les fusibles par desfusibles de même type et demême ampérage.

  • 8/19/2019 Sdm Clarent

    36/144

    SDM-9220/9230 Hardware Installation Guide

    2-16 Memotec Inc.

  • 8/19/2019 Sdm Clarent

    37/144

    3

    Memotec Inc. 3-1

    Unpacking 

  • 8/19/2019 Sdm Clarent

    38/144

    SDM-9220/9230 Hardware Installation Guide

    3-2 Memotec Inc.

    3.1 About Unpacking the Unit

    This chapter outlines preparatory steps that should be executed before you install andconfigure the SDM-9220/9230:

    • Selecting a location (see next section)

    • Preparing the site (“Preparing the Site” on page 3-5).

    3.1.1 Selecting a Location

    To ensure that the SDM-9220/9230 functions properly, you should install the unit in anappropriate location which satisfies certain criteria for size, connection distance andambient environment.

    CAUTION:: Unit must be installed in a restricted access location.

    3.1.2 Size Requi rements

    • Select a standard 19" (48 cm) equipment rack or a hard, flat surface that is:

    - Near an easily accessible AC or DC power source

    - Capable of supporting the weight and size of the SDM-9220/9230, its cablingand attached equipment.

    • To ensure proper ventilation of the SDM-9220/9230, leave 5 cm (2 inches) ofunobstructed space around the unit chassis.

    • Ensure that a sufficient number of shelves, supports, racks and cabinets are avail-able to safely house all equipment.

    Figure 3-1: Front View of the SDM-9220/9230

  • 8/19/2019 Sdm Clarent

    39/144

      Unpacking

    Memotec Inc. 3-3

    3.1.3 Distance Requirements

    • The SDM-9220/9230 unit should be no more than 2 meters (approx. 6 feet) awayfrom an easily accessible power supply appropriate to the type of power supplyon the unit:

    - SDM-9220 UAC or SDM-9230 UAC: 100-240 VAC, (50/60 Hz)

    - SDM-9220 DC or SDM-9230 DC: -48 VDC, (2 Amps maximum)

    WARNING:: In countries where a 2-pin non-grounded power cordmust be used for the SDM-9220 UAC or SDM-9230 UAC, ensurethat the unit is independently grounded with a wire from Groundsecurely attached to the ground lug on the power supply at the rearof the unit chassis.

    For the location of the ground lug, refer to “Rear View of the SDM-9230 UAC” on page 5-2.

    - The maximum length of user equipment connections is relative to the serial(WAN/user) port speed:

    - 6 Mbps: 8 meters (25 feet)

    - 2 Mbps or less: 30 meters (100 feet)

    • There should be no more than 8 meters (25 feet) between modems and WAN link(PVCR) connections.

    • Equipment that is directly connected to the voice interfaces can be placed much

    farther away. Up to 2750 meters (9000 feet) of cable is permitted between each NetPerformer analog interface and its attached equipment.

    NOTE: Distance may be an important factor for an E&M interface on the SDM-9220UAC and SDM-9230 UAC.

    If the PBX and the NetPerformer UAC unit are not near each other (in thesame room, for example) then their AC grounds may not be the same. Refer to“E&M Grounding Considerations” on page 4-25 for a workaround.

  • 8/19/2019 Sdm Clarent

    40/144

    SDM-9220/9230 Hardware Installation Guide

    3-4 Memotec Inc.

    3.1.4 Environmental Requirements

    For trouble-free operation of the SDM-9220/9230 its location must satisfy the followingenvironmental criteria:

    • Operating temperature: 0C to 45C (32F to 113F)*

    • Storage temperature: -20C to 65C (-4F to 149F)

    • Relative humidity: 10% to 90%, non-condensing

    • Maximum operating altitude: 4572 meters (15 000 feet)*

    • Ventilation requirement: leave 5 cm (2 inches) of unobstructed space around theunit. All unused slots must be closed with a plate.

    * NOTE: Above 3048 meters (10 000 feet) altitude the maximum operating temperatureof the unit drops from 45°C to 35°C.

  • 8/19/2019 Sdm Clarent

    41/144

      Unpacking

    Memotec Inc. 3-5

    3.2 Preparing the Site

    3.2.1 What You Wi ll Need

    For trouble-free installation of the NetPerformer hardware make sure you have the

    following on hand:• The SDM-9220 or SDM-9230 unit, with all accessories, cables and optional

    hardware you received in the product package. Refer to “Product Description” on page 5-1.

    • At least one of the following configuration and management access devices:

    - A console terminal (TTY terminal or a PC equipped with terminal emulationsoftware) for direct or dial-up connection to the console port at the rear of theSDM-9220/9230 unit, or

    - A TELNET network device accessed through IP connectivity over LAN/WAN, or

    - An SNMP agent accessed through IP connectivity over LAN/WAN.

    NOTE: When you first take the SDM-9220/9230 out of the box, the only configura-tion device you can use is the console terminal, since the unit does not yethave an IP address. For details, see “Connecting the Console Terminal” on page 4-32.

    CAUTION: If you intend to use the HyperTerminal‰communications program as your console terminal, read the“Notice Concerning HyperTerminal Connections” on page 1-10.

    • A sufficient number and length of cables for all ports:

    - One RJ-48 to RJ-48 cable for each T1/E1 or ISDN-BRI S/T port (at least26AWG, or 0.4mm)

    - Two BNC coaxial cables for each T1/E1 port that will be configured for E1-75 operations

    NOTE: An adaptor is also required for an E1-75 connection on an E1/T1 port. Thefollowing adaptor is available:RJ-48 to E1-75 dual BNC (Part No. AG2CA0001). See “Adaptor Cable” on page 5-31 for details.

  • 8/19/2019 Sdm Clarent

    42/144

    SDM-9220/9230 Hardware Installation Guide

    3-6 Memotec Inc.

    - One custom-made HD-26 cable for each serial port. Details are provided in“Serial Port and User Equipment Connections” on page 6-1.

    - One straight through 10/100BaseT LAN cable, RJ-45M to RJ-45M, for eachEthernet port.

    NOTE: The above cables are not  provided with the SDM-9220/9230 product package.

    - One RJ-11 to RJ-11 cable for each FXS or FXO port

    - One RJ-45 to RJ-45 cable for each E&M/PTT port

    • All user equipment that will be directly connected to the serial ports.

    • A sufficient number of ferrites for the cables connecting to the ports on the unit.Refer to “Installing the Ferrites (EMI Filters)” on page 4-26 for the ferritesrequired on the different product models for the various types of ports, the coun-

    tries where these ferrites are required, and installation instructions.

    NOTE: These ferrites are not provided with the product package.

  • 8/19/2019 Sdm Clarent

    43/144

    4

    Memotec Inc. 4-1

    Hardware Installation

  • 8/19/2019 Sdm Clarent

    44/144

    SDM-9220/9230 Hardware Installation Guide

    4-2 Memotec Inc.

    4.1 Chapter Overview

    Hardware installation of the SDM-9220/9230 involves the following steps:

    • Opening the chassis casing (“Opening the Chassis Casing” on page 4-3)

    • Installing or upgrading the DSP module (“Installing or Upgrading the DSP Mod-

    ule” on page 4-5)• Closing the chassis casing (“Closing the Chassis Casing” on page 4-8)

    • Removing an interface card (“Removing an Interface Card” on page 4-10)

    • Hardware strapping:

    - NT/TE mode on the ISDN-BRI S/T interface cards (“NT/TE Mode” on page 4-12)

    - E1-75 jumpers on the single/dual port T1/E1 interface card (“E1-75 Jumpers”on page 4-14)

    • Installing an interface card (“Installing an Interface Card” on page 4-18)

    • (Optional) Installing the unit in a rack (“Installing the Unit in a Rack” on page 4-21)

    • E&M wiring and grounding procedures (“E&M Wiring and Grounding” on page 4-23)

    • Installing the ferrites for E1-75, FXS, FXO, E&M/PTT and ISDN-BRI S/T con-nections (“Installing the Ferrites (EMI Filters)” on page 4-26)

    • Powering up the unit (“Powering the Unit” on page 4-28)

    • Connecting the console terminal (“Connecting the Console Terminal” on page 4-32)

    • Installing the licensed software options (“Installing the Licensed SoftwareOptions” on page 4-34)

    • (Optional) Connecting the unit to the LAN hub (“Connecting the LAN Hub” on page 4-35)

    • (Optional) Connecting user equipment to the serial ports (“Connecting the UserEquipment” on page 6-4).

  • 8/19/2019 Sdm Clarent

    45/144

      Hardware Installation

    Memotec Inc. 4-3

    4.2 Opening the Chassis Casing 

    NOTE: This procedure must be followed to install a DSP module.

    To open the casing of the SDM-9220/9230 chassis:

    1. Wear an ESD (Electrostatic Sensitive Devices) wrist strap, and attach it to the groundlug on the power supply at the rear of the SDM-9220/9230 chassis.

    Refer to “Rear View of the SDM-9230 UAC” on page 5-2 or “Rear View of theSDM-9230 UAC” on page 5-2 for the exact location of the ground lug.

    CAUTION: Electrostatic charges can damage system components. Always usean ESD wrist strap when accessing internal components of the unit.

    NOTE: In countries where a 2-pin non-grounded power cord must be used, ensurethat the SDM-9220/9230 is independently grounded with a wire from Groundsecurely attached to the ground lug located at the rear of the SDM-9220/9230chassis.

    2. Ensure that the SDM-9220/9230 is securely placed on a hard, flat surface, with the port connectors facing you.

    3. Turn the power switch OFF by pushing it to 0, and unplug the power cord from the power supply.

    WARNING: To avoid electrical shock and damage to the unit, make sure that theunit is disconnected from its power source before you access any of its internalcomponents. Use ESD procedure at all times.

    4. Remove the unit cover:

    a. Remove the 3 screws that secure the lip of the cover to the rear of the unit

    chassis. b. Pull the cover up slightly from the rear of the unit first, to disengage it from the

    clips on the chassis wall that hold it in place.

    c. Nudge the cover forward slightly over the front panel.

  • 8/19/2019 Sdm Clarent

    46/144

    SDM-9220/9230 Hardware Installation Guide

    4-4 Memotec Inc.

    d. Roll the cover off over the front of the unit.

    Figure 4-1: Removing the Cover from the Unit Chassis

    Remove 3 screws

    Lift up fromthe rear 

    Pull forward overthe front panel

  • 8/19/2019 Sdm Clarent

    47/144

      Hardware Installation

    Memotec Inc. 4-5

    4.3 Installing or Upgrading the DSP Module

    Follow the procedure in this section for both installation and upgrade of a DSP module onthe SDM-9220/9230.

    CAUTION: The low-density (DSP-160) and high-density (HD) DSP modules areintended for the SDM-9220 and SDM-9230 only.DO NOT replace the DSP-160 or HD DSP module with a DSP module intendedfor the SDM-9360, SDM-9380 or SDM-9585.Likewise, do not install a DSP-160 or HD DSP module in an SDM-9360, SDM-9380 or SDM-9585 unit.

    NOTE: The synchronous HD DSP module used for GSM applications requires Net-Performer software version 10.2.3 R08 or higher. The synchronous low-den-

    sity DSP module for GSM requires version 10.3.5 R02 or higher. Earliersoftware versions will report a hardware problem and log an error.

    Figure 4-2: Location of Optional Hardware on the Main Board

    Slots for interface cards

    Å Ç É

      DSP Socket

  • 8/19/2019 Sdm Clarent

    48/144

    SDM-9220/9230 Hardware Installation Guide

    4-6 Memotec Inc.

    The optional DSP module is installed in the DSP socket located on the main board of theSDM-9220/9230 unit. See Figure 4-2 for the exact location of the DSP socket.

    You can install either the HD DSP module or the DSP-160 module in this DSP socket.Refer to “DSP Modules” on page 5-11 for a description of these two types of DSPmodules.

    NOTE: To ensure proper digital voice operations and performance, install theoptional DSP module before you power up and configure the unit.

    To install a DSP module:

    1. Open the SDM-9220/9230 chassis casing as described on “Opening the ChassisCasing” on page 4-3, heeding the Caution note concerning ESD procedure, and theWarning to turn the unit off and disconnect the power cord first.

    2. Locate the DSP socket on the main board. It is a standard 72-pin DSP connector

    located in the upper left corner of the unit when looking at the main board from therear. Refer to “Location of Optional Hardware on the Main Board” on page 4-5 forthe exact location.

    3. Holding the DSP module by the edge, carefully remove it from its protective packaging.

    CAUTION: Do not expose the DSP module or the SDM-9220/9230 unit to amagnetic field or electrostatic charge at any time. Damage to their componentscould result. Use ESD procedure at all times.

    4. Hold the DSP module over the DSP socket at an angle of about 15° with its notchededge down, closest to the edge of the unit chassis. Center the module over the socket.

    5. Insert the DSP module into the DSP socket:

    a. First push the bottom edge of the module into the socket.

     b. Then press the top edge back to the right until the module snaps into place between two metal clips at each end of the DSP socket.

    When properly installed, the DSP module should rest at an angle of about 45°.

    CAUTION: Do not force the DSP module into the DSP socket. If the DSP moduledoes not snap into place easily or sit properly in the socket, make sure you haveinserted it with the notched edge down, closest to the edge of the unit chassis.

    6. Close the chassis casing as described on “Closing the Chassis Casing” on page 4-8.

  • 8/19/2019 Sdm Clarent

    49/144

      Hardware Installation

    Memotec Inc. 4-7

    4.3.1 Removing a DSP Module

    CAUTION: DSP modules must be removed with care. Use ESD procedure at all times.

    To remove a DSP module:

    1. Open the SDM-9220/9230 chassis casing as described on “Opening theChassis Casing” on page 4-3, heeding the Caution note concerning ESD procedure, and the Warning to turn the unit off and disconnect the power cordfirst.

    2. Locate the small metal clips that hold the DSP module into place at each endof the DSP socket. Push the clips apart with the tips of your fingers. Themodule will spring into a more vertical position.

    3. Holding the DSP module by its edge, carefully lift it up and out of its socket.

    CAUTION: Do not expose the DSP module or the SDM-9220/9230 unitto a magnetic field or electrostatic charge at any time. Damage to theircomponents could result.

    4. If you are not installing another DSP, replace the unit cover as described inthe next section.

  • 8/19/2019 Sdm Clarent

    50/144

    SDM-9220/9230 Hardware Installation Guide

    4-8 Memotec Inc.

    4.4 Closing the Chassis Casing 

    CAUTION: Do not turn the unit on unless its cover is properly installed andsecured.

    To close the casing of the SDM-9220/9230 chassis:

    1. Hook the bottom lip of the front of the cover onto the bottom of the SDM-9220/9230front panel, using an upward motion.

    NOTE: If the bottom lip of the cover is fitted properly onto the front of the chassis, thelight pipes for the system status LEDs will slip easily into the holes providedfor them.

    2. Keeping the bottom lip in place on the front panel, rotate the rear of the cover downover the unit chassis. You may need to push the cover slightly toward the rear toensure that it is well seated over the rear panel. Refer to Figure 4-3.

  • 8/19/2019 Sdm Clarent

    51/144

      Hardware Installation

    Memotec Inc. 4-9

    3. To secure the lip of the cover to the rear of the unit chassis, replace the three screwsthat you removed earlier. See Figure 4-1 on “Removing the Cover from the UnitChassis” on page 4-4 for their exact location.

    Figure 4-3: Replacing the Cover onto the Unit Chassis

    Hook the cover overthe front panel.

    Roll down overthe rear panel.

  • 8/19/2019 Sdm Clarent

    52/144

    SDM-9220/9230 Hardware Installation Guide

    4-10 Memotec Inc.

    4.5 Removing an Interface Card

    NOTE: This procedure must be followed to change the hardware strapping on aninterface card that has already been installed. (For interface card installation,

    see “Installing an Interface Card” on page 4-18.)

    CAUTION: Interface cards must be removed with care. Use ESD procedure at alltimes.

    To remove an interface card:

    1. At the rear of the SDM-9220/9230 chassis, turn the power switch OFF by pushing itto 0, and unplug the power cord from the power supply.

    WARNING: To avoid electrical shock and damage to the unit, make sure that theunit is disconnected from its power source before you access any of its internalcomponents.

    NOTE: You do not need to disconnect any cables that may be connected to the data(WAN/user), LAN or console ports, or to other interface cards that may bealready installed.

    2. Using a small, non-magnetized Phillips screwdriver, loosen the 2 captive screws thathold the faceplate of the interface card onto the chassis wall.

    3. Pull the interface card horizontally out of the slot using the tips of your fingers. Todisengage the interface card from the connector on the main board, you may need touse a small, non-magnetized flat-head screwdriver to gently pry the faceplate of theinterface card away from the chassis wall. If you must do this, be very careful that youdo not apply too much force on the interface card or its faceplate.

    CAUTION:Do not expose the interface card or the SDM-9220/9230 unit to amagnetic field or electrostatic charge at any time. Damage to their componentscould result.

  • 8/19/2019 Sdm Clarent

    53/144

      Hardware Installation

    Memotec Inc. 4-11

    4. Install a metal faceplate to cover the slot cutout. The metal faceplate goes behind thechassis wall, and can be inserted through the slot opening. To secure the metalfaceplate in place, tighten the 2 captive screws.

    NOTE: To limit electromagnetic interference and ensure optimum ventilation inside

    the unit chassis, there should be no large openings on the rear panel  of theSDM-9220/9230 unit.

  • 8/19/2019 Sdm Clarent

    54/144

    SDM-9220/9230 Hardware Installation Guide

    4-12 Memotec Inc.

    4.6 Hardware Strapping 

    4.6.1 NT/TE Mode

    On the ISDN-BRI S/T interface card, the directionality of the clock signals is set to NT

    (Network Termination) or TE (Terminal Equipment) mode through hardware strapping.

    NOTE:  NT/TE mode is software selectable on the single/dual T1/E1 interface cards.

    • In NT mode, the interface provides the clock signal to the connected device.

    • In TE mode, the interface uses the receive clock from the connected device totransmit data. This is the factory default setting.

    The two ends of a T1 or E1 connection must have opposite NT/TE values. Thus some digitalinterface cards in your application may need to be changed to NT mode. The rule of thumbis:

    • If you are connecting the physical digital port directly to the network (or toanother physical digital port that has been strapped as NT), you do not need tochange the TE factory setting.

    • If you are connecting the physical digital port to user equipment (or to another physical digital port that has been strapped as TE), you must change the NT/TEmode of the interface card to NT.

  • 8/19/2019 Sdm Clarent

    55/144

      Hardware Installation

    Memotec Inc. 4-13

    4.6.2 Setting the NT/TE Mode

    To set the NT/TE mode on an ISDN-BRI S/T interface card you need to strap 2 jumperslocated on the component side of the interface card: jumpers JP5 and JP6. The 2 jumpersoperate independently and can have different settings:

    • JP5 controls the NT/TE setting for port 1

    • JP6 controls the NT/TE setting for port 2.

    For the exact location of JP5 and JP6 examine Figure 4-4.

    To change the jumper setting for NT/TE mode on an ISDN-BRI S/T interface card:

    NOTE: Hard strapping must be done carefully, to ensure that the pins are well-engaged in the jumper base on both sides.

    Figure 4-4: JP5 AND JP6 locations

    Enlarged 2X

    Enlarged 2X

    Jumper for

    termination

    Jumper fortermination

  • 8/19/2019 Sdm Clarent

    56/144

    SDM-9220/9230 Hardware Installation Guide

    4-14 Memotec Inc.

    WARNING: Use extreme caution when setting the NT/TE mode. Jumper positionsmust not be changed while the unit is under power. To avoid electrical shockand damage to the interface card or other hardware components, make sure thatthe unit is disconnected from its power source before you access any of itsinternal components. Use ESD procedure at all times.

    1. Remove the interface card from the SDM-9220/9230 chassis, following the procedure “Removing an Interface Card” on page 4-10.

    2. Determine the current NT/TE setting of the interface card; examine the NT/TEindications written on the interface card near jumpers JP5 and JP6.

    - The jumper blocks for both JP5 and JP6 have 15 pins in a 3x5 formation. 10of these pins (2 rows) are covered by the jumper.

    - The port is set to TE mode at the factory. If you are strapping a new interfacecard, you need to change the factory setting of jumpers JP5 and JP6 only if yourequire NT mode on the interface card.

    3. Hold the interface card firmly in one hand.

    CAUTION: Do not expose the interface card or the SDM-9220/9230 unit to amagnetic field or electrostatic charge at any time. Damage to their componentscould result.

    4. For both JP5 and JP6, moving the jumper from one side to the other changes TE modeto NT, or NT mode to TE. Using needle-nosed pliers, move the jumpers to the pin

     positions required for your interface.

    NOTE: On the ISDN-BRI S/T interface card, the two jumpers can have different set-tings, as JP5 controls port 1 and JP6 controls port 2 independently of eachother.

    CAUTION: Correct configuration of the NT/TE mode jumpers is extremelyimportant. If you do not strap the digital interface card correctly, the line will be

    down and transmission cannot take place. Make sure that each physicalconnection is configured for NT mode at one end, and TE mode at the other.

    4.6.3 E1-75 Jumpers

    On the si