Science Learning Center Chemistry Pre-laboratory Tutorials. Written By Patrick Herklotz. Instructions. Step # . Location of Written Instructions. Menu Options: Click on Links To…. Previous Slide. Link : Go to Preceding Slide. Link : Watch Current Slide Animations Again. Replay. - PowerPoint PPT Presentation
Citation preview
Science Learning Center
Chemistry Pre-laboratory Tutorials
Written By Patrick Herklotz
Menu Options: Click on Links To…
Replay
Continue
Step # Location of Written Instructions
Link: Go to Preceding Slide
Link: Watch Current Slide Animations Again
Link: Advance to Next Slide
Instructions
Previous Slide
Menu Options: Click on Links To…
Replay
Continue
Step # Location of Written Instructions
Link: Go to Preceding Slide
Link: Watch Current Slide Animations Again
Link: Advance to Next Slide
Instructions
Previous Slide
Tutorial 2 Obtaining Temperature Data Using the LabPro Calculator & Downloading
this Data With the LoggerPro Computer Program
Previous Slide
Replay
Continue
Top View
Previous Slide
Replay
Continue
Side View
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
Channel 1 Channel 2 Channel 3 Channel 4
Power Supply
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Step 1: Assemble the LabPro Calculator as explained in Tutorial 1
Top View
Previous Slide
Replay
Continue
Side View
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
Channel 1 Channel 2 Channel 3 Channel 4
Power Supply
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Step 1: Assemble the LabPro Calculator as explained in Tutorial 1
Previous Slide
Replay
Continue
Side View
Channel 1 Channel 2 Channel 3 Channel 4
Step 2: Obtain the thermometer probe and plug it into the left side port of the calculator labeled Channel 1
Top View
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
Power Supply
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Side View
Channel 1 Channel 2 Channel 3 Channel 4
Step 2: Obtain the thermometer probe and plug it into the left side port of the calculator labeled Channel 1
Channel 1 Port
click
Top View
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
Power Supply
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 2: Turn Calculator On by pressing the ON key
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
Previous Slide
Replay
Continue
Step 2: Turn Calculator On by pressing the ON key
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
Previous Slide
Replay
Continue
Step 3: Press the button with the light pink/purple lettering that says APPS
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
Previous Slide
Replay
Continue
Step 3: Press the button with the light pink/purple lettering that says APPS
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
APPLICATIONSFinance...
CSheetE
ALG1CH5ALG1PRT1AreaFormCBL/CBRCsheetDe
1:2:3:4:5:6:7
Previous Slide
Replay
Continue
Step 4: Either scroll down the menu to the DataMate program using the down arrow key or press the green ALPHA button followed by the x-1 (D) button to take you to the programs that start with the letter D
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
APPLICATIONSFinance...
CSheetE
ALG1CH5ALG1PRT1AreaFormCBL/CBRCsheetDe
1:2:3:4:5:6:7
Previous Slide
Replay
Continue
Step 4: Either scroll down the menu to the DataMate program using the down arrow key or press the green ALPHA button followed by the x-1 (D) button to take you to the programs that start with the letter D
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
Press ALPHA then x-1 ( or “D”) buttons
APPLICATIONSDansk
GeoMastr
DataMateDeutscheEspañolFrancaisFunSci
:::::
APPLICATIONSFinance...
CSheetE
ALG1CH5ALG1PRT1AreaFormCBL/CBRCsheetDe
1:2:3:4:5:6:7
Previous Slide
Replay
Continue
Step 5: Press the “down arrow key” until the DataMate program colon is highlighted; press enter to start the program. It will begin with a default screen
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
APPLICATIONSDansk
GeoMastr
DataMateDeutscheEspañolFrancaisFunSci
:::::
Previous Slide
Replay
Continue
Step 5: Press the “down arrow key” until the DataMate program colon is highlighted; press enter to start the program. It will begin with a default screen
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
APPLICATIONSDansk
GeoMastr
DataMateDeutscheEspañolFrancaisFunSci
:::::
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
VERNIER SOFTWARE DATAMATE
(VER 1.15)
ROM 6.27 (C)2003
Previous Slide
Replay
Continue
Step 6: Calibrate the thermometer probe to room temperature by pressing the “1” key: make sure that the cursor triangle is to the left of CH 1 on the top of the next menu; press the “3” key than the “1” key again in the next menus; press the “ENTER” key to zero all channels when prompted
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
Previous Slide
Replay
Continue
Step 6: Calibrate the thermometer probe to room temperature by pressing the “1” key: make sure that the cursor triangle is to the left of CH 1 on the top of the next menu; press the “3” key than the “1” key again in the next menus; press the “ENTER” key to zero all channels when prompted
Top ViewPower Supply
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
CH 1: STAINLESS TEMP (C)CH 2:CH 3:CH 4:DIG1:DIG2:MODE: TIME GRAPH-180
1:OK 3:ZERO2:CALIBRATE 4:SAVE/LOAD
SELECT CHANNEL1: ALL CHANNELS
CH 1: TEMP (C) 999.9
PRESS [ENTER] TO ZERO
CH 1: Temp (C) 26.1
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
Thermometer is now Calibrated!
TI-84 Silver Edition
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
TI-84 Silver EditionTexas Instruments
VERNIER SOFTWARE DATAMATE
(VER 1.15)
ROM 6.27 (C)2003
TI-84 Silver EditionTexas Instruments
CH 1: STAINLESS TEMP (C)CH 2:CH 3:CH 4:DIG1:DIG2:MODE: TIME GRAPH-180
1:OK 3:ZERO2:CALIBRATE 4:SAVE/LOAD
TI-84 Silver EditionTexas Instruments
SELECT CHANNEL1: ALL CHANNELS
TI-84 Silver EditionTexas Instruments
CH 1: TEMP (C) 26.1
PRESS [ENTER] TO ZERO
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 26.1
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
Calibrating Thermometer: Review of Steps 3-6Previous Slide
Replay
Continue
(1) Press 1: SETUP (2) Press 3: ZERO
Cursor For Channel Selection
Opening Screen
(3) Press 1: Zero All Channels (4) Press ENTER Key (5) Returned To Main Screen
Texas Instruments
TI-84 Silver Edition
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
TI-84 Silver EditionTexas Instruments
VERNIER SOFTWARE DATAMATE
(VER 1.15)
ROM 6.27 (C)2003
TI-84 Silver EditionTexas Instruments
CH 1: STAINLESS TEMP (C)CH 2:CH 3:CH 4:DIG1:DIG2:MODE: TIME GRAPH-180
1:OK 3:ZERO2:CALIBRATE 4:SAVE/LOAD
TI-84 Silver EditionTexas Instruments
SELECT CHANNEL1: ALL CHANNELS
TI-84 Silver EditionTexas Instruments
CH 1: TEMP (C) 26.1
PRESS [ENTER] TO ZERO
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 26.1
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
Calibrating Thermometer: Review of Steps 3-6Previous Slide
Replay
Continue
(1) Press 1: SETUP (2) Press 3: ZERO
Cursor For Channel Selection
Opening Screen
(3) Press 1: Zero All Channels (4) Press ENTER Key (5) Returned To Main Screen
Texas Instruments
Previous Slide
Replay
Continue
Step 7: Fill a beaker ¾ full of water. Set the beaker on a hotplate and bring it to a boil using boiling chips. Once boiling, set the thermometer into the beaker of water and place it through a ring stand clip to hold the thermometer in place.
Top ViewPower Supply
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 21.6
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
50
100
150
250
300
0 ml
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 7: Fill a beaker ¾ full of water. Set the beaker on a hotplate and bring it to a boil using boiling chips. Once boiling, set the thermometer into the beaker of water and place it through a ring stand clip to hold the thermometer in place.
Top ViewPower Supply
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 21.6
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
50
100
150
250
300
0 ml
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 8: Once the thermometer probe is placed in the boiling water, press 2 on the calculator to begin recording temperatures for 15 minutes. A graph should appear with a line that slowly comes across the screen signifying that values are being recorded every few seconds.
Top ViewPower Supply
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
50
100
150
250
300
0 ml
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
CH 1: Temp (C) 21.6
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
Previous Slide
Replay
Continue
Step 8: Once the thermometer probe is placed in the boiling water, press 2 on the calculator to begin recording temperatures for 15 minutes. A graph should appear with a line that slowly comes across the screen signifying that values are being recorded every few seconds.
Top ViewPower Supply
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
CH 1: Temp (C) 21.6
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
50
100
150
250
300
0 ml
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
93.8
Elapsed Time (6 minutes)
50.645.226.9P1
y=93.8
TEMP (C)
TIME(S)X=0 Review of Temperatures Recoded Every 2 seconds
Time of Recorded Temperature (seconds)
Previous Slide
Replay
Continue
Step 9: When the Thermometer is finished taking readings, it will display a review graph. Press the ENTER key to exit this screen and return to the main screen. On the main screen press 6 and then the ENTER key again to record the thermometer readings in List 1 and List 2 of the calculator’s memory: the data is now stored.
Top ViewPower Supply
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
50
100
150
250
300
0 ml
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
P1
y=93.8
TEMP (C)
TIME(S)X=0
Previous Slide
Replay
Continue
Step 9: When the Thermometer is finished taking readings, it will display a review graph. Press the ENTER key to exit this screen and return to the main screen. On the main screen press 6 and then the ENTER key again to record the thermometer readings in List 1 and List 2 of the calculator’s memory: the data is now stored.
Top ViewPower Supply
LabPro Calculator Screen
TI-84 Silver EditionTexas Instruments
50
100
150
250
300
0 ml
VERNIER
LabPro
Quick SetupStart/StopTransfer
Vernier
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
P1
y=93.8
TEMP (C)
TIME(S)X=0
CH 1: Temp (C) 21.6
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
TIME IN L1CH1 IN L2CH2 IN L3CH3 IN L4CH4 IN L5D IN L6, V In L7A IN L8 [ENTER]
TI-89 Silver EditionTexas Instruments
VERNIER SOFTWARE DATAMATE
(VER 1.15)
ROM 6.27 (C)2003
TI-89 Silver EditionTexas Instruments
93.8
TI-89 Silver EditionTexas Instruments
TI-89 Silver EditionTexas Instruments
P1
y=93.8
TEMP (C)
TIME(S)X=0
TIME IN L1CH1 IN L2CH2 IN L3CH3 IN L4CH4 IN L5D IN L6, V In L7A IN L8 [ENTER]
Exiting Recorded Data Screens: Review of Steps 8-9
Previous Slide
Replay
Continue
(1) Temperature Recording Screen (2) Recorded Data Screen: Press ENTER Key To Exit This Screen
TI-84 Silver Edition
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
(3) Press 6: QUIT program
Texas Instruments
(4) Press ENTER Key to Record Data
(5) Temperature Data Has Now been Recorded in List 1 & List 2 of the Calculator’s Memory
TI-89 Silver EditionTexas Instruments
VERNIER SOFTWARE DATAMATE
(VER 1.15)
ROM 6.27 (C)2003
TI-89 Silver EditionTexas Instruments
93.8
TI-89 Silver EditionTexas Instruments
TI-89 Silver EditionTexas Instruments
P1
y=93.8
TEMP (C)
TIME(S)X=0
TIME IN L1CH1 IN L2CH2 IN L3CH3 IN L4CH4 IN L5D IN L6, V In L7A IN L8 [ENTER]
Exiting Recorded Data Screens: Review of Steps 8-9
Previous Slide
Replay
Continue
(1) Temperature Recording Screen (2) Recorded Data Screen: Press ENTER Key To Exit This Screen
TI-84 Silver Edition
CH 1: Temp (C) 999.9
Mode: TIME GRAPH-180
1: SETUP 4: ANALYZE2: START 5: TOOLS3: GRAPH 6: QUIT
(3) Press 6: QUIT program
Texas Instruments
(4) Press ENTER Key to Record Data
(5) Temperature Data Has Now been Recorded in List 1 & List 2 of the Calculator’s Memory
Previous Slide
Replay
Continue
Step 9: Obtain a USB Link cable for the TI-84 Calculator. Plug one side of the cable into the TI-84 Calculator circular port at the front of the calculator and the other side (USB connector plug) into one of the USB ports on a computer in the SLC.
Front View of TI-84
Link Cable
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 9: Obtain a USB Link cable for the TI-84 Calculator. Plug one side of the cable into the TI-84 Calculator circular port at the front of the calculator and the other side (USB connector plug) into one of the USB ports on a computer in the SLC.
Front View of TI-84
Front Link Port
USB Port Usual Location
Link Cable
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
click
click
Previous Slide
Replay
Continue
Step 10: Click on the General Chemistry Desktop Icon. In the next window, double click the icon that says LoggerPro to open this program. Click CLOSE on the text box link to exit the “tip of the day text.”
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 10: Click on the General Chemistry Desktop Icon. In the next window, double click the icon that says LoggerPro to open this program. Click CLOSE on the text box link to exit the “tip of the day text.”
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 10: Click FILE, Import From then click TI Device. Click on the Port pull down menu and select TI-GRAPH LINK (tm)-USB. If no lists appear in the white “choose data import box”, click the Refresh Catalog link. Once the lists appear in this text box, left click on L1 and L2 to select your time vs. temperature recordings stored in the TI-84 memory and than click OK to import this data into Logger Pro.
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 10: Click FILE, Import From then click TI Device. Click on the Port pull down menu and select TI-GRAPH LINK (tm)-USB. If no lists appear in the white “choose data import box”, click the Refresh Catalog link. Once the lists appear in this text box, left click on L1 and L2 to select your time vs. temperature recordings stored in the TI-84 memory and than click OK to import this data into Logger Pro.
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Sample Data
Previous Slide
Replay
Continue
Step 10: Use the cursor to select the data listed in L1 and L2 text box. Once selected (highlighted grey), right click on the selected data and click COPY. Paste this data into a Microsoft Excel Spread Sheet for further graphing and analysis. Refer to the written EXCEL Pre laboratory packet for the proper graphing procedures for using the Microsoft Excel program.
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
Previous Slide
Replay
Continue
Step 10: Use the cursor to select the data listed in L1 and L2 text box. Once selected (highlighted grey), right click on the selected data and click COPY. Paste this data into a Microsoft Excel Spread Sheet for further graphing and analysis. Refer to the written EXCEL Pre laboratory packet for the proper graphing procedures for using the Microsoft Excel program.
STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5
Alpha
2ND Mode DEL
STAT
PRGM
COS
(
X,T,O,N
APPSMATH
7
4
1
0
8
5
2
.
9
6
3
(-)
x
+
-
÷
Enter
X -1
X2
LOG
LN
STO>
ON
SIN
,
VARS CLEAR
TAN
>
)
End of Tutorial 2
Menu Options
Back to Beginning
Previous Slide
Finished
End of Tutorial 2
Menu Options
Back to Beginning
Previous Slide
Finished