20
Schneider Sepam Selection Guide 2014-07-08 Rev. Status Date Issued by Checked by Approved by 00 AFC 08-Jul-2014 JYL JYL MHJ Approved for construction DongYang Engineering Schneider Sepam Protection Relay Selection Guide Revision Memo Schneider Sepam Protection Relay Selection Guide Document Number DYE-STD- Revision : 00 Status : AFC Date 10-DEC-2013 Page : 1 / 23 1/20 JY.LEE

Schneider Sepam Protection Relay Selection Guide(2014.02.05)

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Rev. Status Date Issued by Checked by Approved by

00 AFC 08-Jul-2014 JYL JYL MHJApproved for construction

DongYang Engineering

SchneiderSepam

Protection Relay Selection Guide

Revision Memo

Schneider Sepam Protection RelaySelection Guide

Document Number

DYE-STD-Revision : 00 Status : AFCDate 10-DEC-2013Page : 1 / 23

1/20 JY.LEE

Page 2: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Schneider Sepam Protection Relay Selection GuideSelection 1 1. Sepam Base Unit : 20Series, 40Series

2/20 JY.LEE

Page 3: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 1 1. Sepam Base Unit : 80Series

3/20 JY.LEE

Page 4: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 2 2. Sepam User-Machine Interface : With basic UMI, With remote advanced UMI(DSM303), With integrated advanced UMI, With mimic-based UMI(Sepam S80)

4/20 JY.LEE

Page 5: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 3 3. Protection Application :

Selection 4 4. Protection : 50/51,50N/51N,50G/51G,50BF,46,49RMS,51C,64REF,87T,87M,67,67N/67NC,32P,32Q,37P,37,48/51R,66,40,78PS,12,14,50V/51V,21B,50/27,27TN/64G2,64G,24,2727D,27R,59,59N,47,81H,81L,81R,79,26/63,38/49T,25,94/96,67,86,30,60/60FL,74 & etc.

Substation, Busbar, Transformer, Motor, Generator, Capacitor

5/20 JY.LEE

Page 6: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

6/20 JY.LEE

Page 7: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

7/20 JY.LEE

Page 8: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

8/20 JY.LEE

Page 9: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 5 5. ConnectionA. Main Analog Input :

B. Additional Analog Inputs :

- S80serise Added to CCA630(3 additional phase current inputs), CCA634(3 additional phase current inputs,1 additional residual current input), CCT640(3 additional phase voltage inputs, 1 additional residual voltage input)

3 additional phase current inputs (l’1, l’2, l’3), 1 additional residual current input (l’0), 3 additional phase voltage inputs (V’1, V’2, V’3),1 additional residual voltage input (V’0)

3 phase current inputs (l1, l2, l3), 1 residual current input (l0), 3 phase voltage inputs (V1, V2, V3), 1 residual voltage input (V0)

9/20 JY.LEE

Page 10: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

10/20 JY.LEE

Page 11: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 6 6. Input/Output Signal : Adding to Extend Module (S20/40 - MSE114(I:10, O:4), S80 - MES120(I:14, O:6, Added MAX. 3set)

11/20 JY.LEE

Page 12: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

12/20 JY.LEE

Page 13: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 7 7. Communication (Option)

A. Modbus RTU :

B. DNP3 :

C. IEC 60870-5-103 :

D. Modbus TCP/IP :

E. IEC 61850 :

F. Ethernet gateway :

Connection of communication interfaces - RS232 network, RS 485 network(2-wire, 4-wire), Fiber-optic network

EGX100, EGX300

ACE850TP(Ethernet), ACE850FO(Fiber optic), ECI850(RS 485 network 2 & 4-wire, RJ45)

ACE850TP(Ethernet), ACE850FO(Fiber optic)

RS 485 network for ACE969TP-2(2-wire), ACE969FO-2(Fiber optic) interfaces /ACE909-2(RS232/RS485), ACE919CA & ACE919CC (RS485/RS485) converter

RS 485 network for ACE969TP-2(2-wire), ACE969FO-2(Fiber optic) interfaces /ACE909-2(RS232/RS485), ACE919CA & ACE919CC (RS485/RS485) converter

RS 485 network for ACE949-2(2-wire), ACE959(4-wire) and ACE937(Fiber-optic), ACE969TP-2(RS485), ACE969FO-2(Fiber optic) interfaces / ACE909-2(RS232/RS485), ACE919CA & ACE919CC (RS485/RS485) converter

13/20 JY.LEE

Page 14: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 8 8. Temperature sensor (Option) :

Selection 9 9. Analog output module (Option) :

Selection 10 10. Synchro-check module (Option) :

Selection 11 11. remote advanced UMI module (Option) DSM303

MCS025

MSA141

MET148-2

14/20 JY.LEE

Page 15: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

15/20 JY.LEE

Page 16: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

16/20 JY.LEE

Page 17: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

17/20 JY.LEE

Page 18: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

Selection 12 12. Accessories (Option) : Core balance CTs

Cable

Control & Monitoring

Base Units Connectors

Software Tool

18/20 JY.LEE

Page 19: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

19/20 JY.LEE

Page 20: Schneider Sepam Protection Relay Selection Guide(2014.02.05)

Schneider Sepam Selection Guide 2014-07-08

20/20 JY.LEE