4
Scandinavian Boiler Service SBS MARINE BOILER PROTECTION SBS - YOUR GLOBAL PARTNER 24hrs. worldwide support number 1-954-767-0309 www.sbs-international.com Protect your boilers and economizers by monitoring their thermal conditions and performance. The unique feature of the G5xxx Series is the dynamic load depen- dent monitoring. Any boiler and economizer behaves differently under different load conditions. Problems that are harmless under low load conditions can become fatal under high load. Here the G5xxx Series gives you adequate and early warnings.

SBS Boiler Protection · MARINE BOILER PROTECTION SBS - YOUR GLOBAL PARTNER 24hrs. worldwide support number 1-954-767-0309 Protect your boilers and economizers by monitoring their

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SBS Boiler Protection · MARINE BOILER PROTECTION SBS - YOUR GLOBAL PARTNER 24hrs. worldwide support number 1-954-767-0309 Protect your boilers and economizers by monitoring their

Scandinavian Boiler ServiceSBS

MARINE BOILER PROTECTION

SBS - YOUR GLOBAL PARTNER24hrs. worldwide support number

1-954-767-0309www.sbs-international.com

Protect your boilers and economizers by monitoring their thermal conditions and performance. The unique feature of the G5xxx Series is the dynamic load depen-dent monitoring. Any boiler and economizer behaves differently under different load conditions. Problems that are harmless under low load conditions can become fatal under high load. Here the G5xxx Series gives you adequate and early warnings.

Page 2: SBS Boiler Protection · MARINE BOILER PROTECTION SBS - YOUR GLOBAL PARTNER 24hrs. worldwide support number 1-954-767-0309 Protect your boilers and economizers by monitoring their

Temperature & Pressure Drop Monitoringfor G50x0 EGEM and G52x0 EGEM light

Soot-fi re accidents in exhaust gas economizers after diesel engines are an increasing problem often caused by low grade fuels, fuel changes, and reduced engine speed. The solution to prevent this problem is simple: Keep the econ-omizer reasonably clean at all times. Our monitors provide your crew with the information to ensure this.

The data on pressure drop and temperatures in compari-son to the current load gives you precise information con-cerning the economizer’s heat exchange conditions. The single parameters vary greatly dependent on the load of the economizer. With this information you are able to de-tect a range of troubles such as soot deposits on the gas side or oil contamination on the water side.

Water Circulation Monitoring for G50x0 EGEM

Suffi cient water circulation is crucial for containing soot burning, which is likely to occur. Soot burning is by itself not enough to cause a major EGE breakdown. It usually dies out due to the cooling eff ect of the boiler water. If however the water circulation is reduced (e.g. due to ex-cessive steam production, steam blockage, pump cavita-tion, scale build up, or the like), the heat transfer is reduced or even lost. This will let soot burning develop into high-temperature fi res and boiler meltdown.

Monitoring the water circulation is therefore the key to preventing fatal failures. The G50x0 EGEM can automati-cally start the stand-by pump.

G55x0 Oil-Fired Boiler Monitor

Key Features G5xxx Series

Maintain economizer/boiler effi ciency Reduce thermal stress Prevent soot-fi res Cost-eff ective protection against high damage risk

Dynamic, load-dependent monitoring of multiple parameters

Indication for optimized cleaning intervals Relay functions for reduced heat-transfer due to

soot, scale, oil contamination, or water failure— can be used to slow down engine or boiler

Relay functions for low water circulation (G50x0)— can be used to start the stand-by pump

Modular design for customized confi guration Confi gurable measuring range and output Confi gurable alarms Easy integration to any boiler control system Analog output — option for RS485 data link

Worldwide customer support via service partners

The G55x0 Oil-Fired Boiler Monitor is designed as a modu-lar system for dynamic monitoring of the boiler’s thermal condition and furnace back-pressure. It measures the fl ue gas temperature and pressure drop across the boiler. This gives a good indication for a range of potential problems:

poor combustion and soot deposits on the gas side;scale build-up or oil contamination on the water side.

With the G55x0 OFB Monitor your crew can maintain its effi ciency with appropriate cleaning, optimize the boiler performance, and save fuel.

Both fl ue gas temperature and pressure drop depend on the actual boiler load. Some boilers have a tempera-ture sensor or even a static pressure drop alarm. But the information derived from these systems is of limited use. Such a static control system cannot detect problems while operating under low and medium load conditions. They are designed not to give false alarms even under high load conditions and thus these control systems only have alarms for a temperature and pressure-drop level that oc-cur under full load.

The G55x0 Oil Fire Boiler Monitor on the contrary will add full value to your boiler control system and a true protec-tion for your boiler as it gives dynamic alarms along with the actual boiler load.

Dynamic, load-dependent pressure drop curve

G50x0/52x0 Exhaust Gas Economizer Monitor

Diagram of the G50x0 EGE Monitor

020406080

100120140

0 20 40 60 80 100Engine or Boiler Load in %

Pres

sure

drop

inm

mW

C dynamicalarm curveperformancecurve

static high pressure drop alarm

deficit of a static fault detection system

dynamicalarm curveperformancecurve

Power

InletInlet Temperature

Water Circulation Flow

Outlet TemperatureOutlet

Pressure Drop

Sig

nal

Pow

er

Engine Load

RemoteInput

ModuleS

igna

l

Pow

er

Engine Room

Engine Control Room

Interfaceand Power

Module

Engine LoadInlet

Inlet Temperature

Water Circulation Flow

Outlet Temperature

Pressure Drop

Outlet 240 deg.C

75 mm WC

290 deg.C

10 cbm/h

90 %

Exhaust Gas Exonomizer Monitor

Boiler Control Panle with eitherControler (G5000) or Screen (G5010)

G5000brochure2010.indd 3-4 09/03/2010 09:50:28

SBS

Page 3: SBS Boiler Protection · MARINE BOILER PROTECTION SBS - YOUR GLOBAL PARTNER 24hrs. worldwide support number 1-954-767-0309 Protect your boilers and economizers by monitoring their

Temperature & Pressure Drop Monitoringfor G50x0 EGEM and G52x0 EGEM light

Soot-fi re accidents in exhaust gas economizers after diesel engines are an increasing problem often caused by low grade fuels, fuel changes, and reduced engine speed. The solution to prevent this problem is simple: Keep the econ-omizer reasonably clean at all times. Our monitors provide your crew with the information to ensure this.

The data on pressure drop and temperatures in compari-son to the current load gives you precise information con-cerning the economizer’s heat exchange conditions. The single parameters vary greatly dependent on the load of the economizer. With this information you are able to de-tect a range of troubles such as soot deposits on the gas side or oil contamination on the water side.

Water Circulation Monitoring for G50x0 EGEM

Suffi cient water circulation is crucial for containing soot burning, which is likely to occur. Soot burning is by itself not enough to cause a major EGE breakdown. It usually dies out due to the cooling eff ect of the boiler water. If however the water circulation is reduced (e.g. due to ex-cessive steam production, steam blockage, pump cavita-tion, scale build up, or the like), the heat transfer is reduced or even lost. This will let soot burning develop into high-temperature fi res and boiler meltdown.

Monitoring the water circulation is therefore the key to preventing fatal failures. The G50x0 EGEM can automati-cally start the stand-by pump.

G55x0 Oil-Fired Boiler Monitor

Key Features G5xxx Series

Maintain economizer/boiler effi ciency Reduce thermal stress Prevent soot-fi res Cost-eff ective protection against high damage risk

Dynamic, load-dependent monitoring of multiple parameters

Indication for optimized cleaning intervals Relay functions for reduced heat-transfer due to

soot, scale, oil contamination, or water failure— can be used to slow down engine or boiler

Relay functions for low water circulation (G50x0)— can be used to start the stand-by pump

Modular design for customized confi guration Confi gurable measuring range and output Confi gurable alarms Easy integration to any boiler control system Analog output — option for RS485 data link

Worldwide customer support via service partners

The G55x0 Oil-Fired Boiler Monitor is designed as a modu-lar system for dynamic monitoring of the boiler’s thermal condition and furnace back-pressure. It measures the fl ue gas temperature and pressure drop across the boiler. This gives a good indication for a range of potential problems:

poor combustion and soot deposits on the gas side;scale build-up or oil contamination on the water side.

With the G55x0 OFB Monitor your crew can maintain its effi ciency with appropriate cleaning, optimize the boiler performance, and save fuel.

Both fl ue gas temperature and pressure drop depend on the actual boiler load. Some boilers have a tempera-ture sensor or even a static pressure drop alarm. But the information derived from these systems is of limited use. Such a static control system cannot detect problems while operating under low and medium load conditions. They are designed not to give false alarms even under high load conditions and thus these control systems only have alarms for a temperature and pressure-drop level that oc-cur under full load.

The G55x0 Oil Fire Boiler Monitor on the contrary will add full value to your boiler control system and a true protec-tion for your boiler as it gives dynamic alarms along with the actual boiler load.

Dynamic, load-dependent pressure drop curve

G50x0/52x0 Exhaust Gas Economizer Monitor

Diagram of the G50x0 EGE Monitor

020406080

100120140

0 20 40 60 80 100Engine or Boiler Load in %

Pres

sure

drop

inm

mW

C dynamicalarm curveperformancecurve

static high pressure drop alarm

deficit of a static fault detection system

dynamicalarm curveperformancecurve

Power

InletInlet Temperature

Water Circulation Flow

Outlet TemperatureOutlet

Pressure Drop

Sig

nal

Pow

er

Engine Load

RemoteInput

Module

Sig

nal

Pow

er

Engine Room

Engine Control Room

Interfaceand Power

Module

Engine LoadInlet

Inlet Temperature

Water Circulation Flow

Outlet Temperature

Pressure Drop

Outlet 240 deg.C

75 mm WC

290 deg.C

10 cbm/h

90 %

Exhaust Gas Exonomizer Monitor

Boiler Control Panle with eitherControler (G5000) or Screen (G5010)

G5000brochure2010.indd 3-4 09/03/2010 09:50:28

Page 4: SBS Boiler Protection · MARINE BOILER PROTECTION SBS - YOUR GLOBAL PARTNER 24hrs. worldwide support number 1-954-767-0309 Protect your boilers and economizers by monitoring their

Helbo Grafisk . Tlf. 6131 6462 www.sbs-international.com

Scandinavian Boiler ServiceSBS

OrganizationThe SBS service organization is located in four geographic areas: Europe, the United States, Middle East

and South East Asia. Each center operates a number of strategically located service and repair centers in the region.

Scandinavian Boiler ServiceDenmark

Tel. + 45 7027 1000Fax + 45 7027 1001

Email [email protected]

Scandinavian Boiler ServiceLauderdale USA

Tel. + 1 954 763 7375Fax + 1 954 766 2624

Email [email protected]

Scandinavian Boiler ServiceDubai

Tel. + 971 56 13 32 584

Email [email protected]

Scandinavian Boiler ServiceSingapore

Tel. +65 6767 0200Fax +65 6364 0300

Email [email protected]

WE KEEP YOU OPERATIONAL!