  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds1162

    10L

    CCH UX Series LED Exit Signs

    UL ListedAvailable with Cl. I, Div. 2,Groups A, B, C, D rating

    NEMA 4X, IP6610L

    The Cooper Crouse-Hinds CCH UX Series LED Exit Sign combinesthe strength and durability of die cast aluminum with architecturally-pleasing aesthetics. The CCH UX Series is illuminated by LEDs,providing the customer with a long-life, low maintenance,dependable exit sign for use in conditions where reliability is crucial.

    Designed for the most severe environments, the CCH UX Series willprovide maximum performance against rain, moisture, cold,corrosion, and dust in applications such as manufacturing plants,refineries, petrochemical and chemical plants, waste and sewagetreatment facilities, food processing, and other industrial facilities.

    Applications: In locations deemed hazardous due to the presence of flammable

    vapors or gases In areas where the presence of gases or vapors may become

    present during an abnormal, unusual, or accidental conditions Outdoor and wet applications Where required by the National Electrical Code, Life Safety

    Code, or other applicable codes

    Benefits of LED Technology: Provides safe and reliable exit marking both indoors and outdoors

    during power failure or interruption of power to normal lightingsystem

    Long life (>50K hours) for years of maintenance-free operation Energy-efficient for lower cost of operation Low temperature operation with no loss of illumination Rugged and durable light source for the harshest of environments

    Certifications and Compliances: NEMA 4X, UL50 UL924 wet location IP65, IP66 Available with NEC hazardous location rating

    - UL844 Class I, Division 2, Groups A, B, C, D

    Temperature Performance Data:CCH UX Series Exit Sign: -45C (-49F) to 45C (113F)CCH UX-HAZ Hazardous Location Exit Sign: T6 rating at 45C (113F)

    Ordering Information:Catalog Number Housing Finish Letter Color

    CCH UX70RSDHAZ Silver Housing Red LEDCCH UX60RHAZ Silver Housing Red LEDCCH UX70GSDHAZ Silver Housing Green LEDCCH UX60GHAZ Silver Housing Green LEDCCH UX70RSD Silver Housing Red LEDCCH UX70RWHSD White Housing Red LEDCCH UX70RBKSD Black Housing Red LEDCCH UX60R Silver Housing Red LEDCCH UX60RWH White Housing Red LEDCCH UX60RBK Black Housing Red LEDCCH UX70GSD Silver Housing Green LEDCCH UX70GWHSD White Housing Green LEDCCH UX70GBKSD Black Housing Green LEDCCH UX60G Silver Housing Green LEDCCH UX60GWH White Housing Green LEDCCH UX60GBK Black Housing Green LED

    Electrical Ratings: Power Supply

    120V/277V dual voltage LED Exits - Red

    Input Power120V = 2.7W277V = 3.2W

    Input Current:(Max.)120V = .07A277V = .04A

    LED Exits - GreenInput Power120V = 2.3W277V = 3.0W

    Input Current:(Max.)120V = .08A277V = .03A

    DimensionsIn Inches:

    Features and Benefits: Wet location, outdoor rated for use in the most demanding

    environments Optional hazardous location rating available Dual voltage 120V/277V reduces wiring errors Heavy-duty nickel cadmium battery for long life 24-hour charge and recharge recovery time increases safety Heavy-duty injection molded polycarbonate lens protects against

    impact and corrosion Brown-out protection protects battery and reduces labor Heavy-duty aluminum die cast housing protects against impact

    and chemical resistance LEDs provide long life, even illumination, and energy savings Wide operating temperature range (-45C to 45C) Self-diagnostic testing reduces costs by eliminating scheduled

    equipment verification tests Heavy duty nickel cadmium battery for long life meets 90 minute

    requirements for battery operated emergency system

    Mounting: wall mount, ceiling mount, end mountConduit Entry: top, bottom, or either side of the unit

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1155

    10L10LCPMVFB Emergency

    Compact FluorescentContinuous OperationChamp-Pak Luminaires

    Cl. I, Div. 2, Groups A, B, C, DRestricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)

    Cl. II, Groups E, F, G; Cl. III &Simultaneous Presence*Marine & Wet Locations3, 3R, 4, 4X; IP66Emergency Lighting

    Applications: Where emergency lighting is required to

    permit workers in industrial areas tosafely encounter their surroundingsduring power failures

    Where emergency egress lighting isrequired, such as: catwalks, walkways,tunnels, doorways, stairs, stairwells,ramps and aisles

    Indoor and outdoor wall mounting orvertical surface mounting where minimalluminaire depth is required in: Manufacturing plants and heavyindustrial facilities Industrial process facilities such asrefineries, chemical, petrochemical,pharmaceutical, and platforms Waste or sewage treatment plants Offshore, dockside, and harborinstallations

    For security and safety lighting inindustrial facilites for lighting of loadingdocks, tunnels, and stairways

    For marine, wet location, hose down,and corrosive environments

    Features and Benefits: Unique compact shallow profile design

    mounts virtually anywhere Side hinged cover with two screw

    closing for easy installation andmaintenance

    Gray Corro-free epoxy powder coattwo-piece housing provides superiorcorrosion resistance

    Unique stainless steel wire guardaccessory attaches without anyadditional hardware for easy installationand maintenance

    Glass refractor provides uniform lightdistribution to eliminate glare

    Silicon gaskets make luminaire suitablefor NEMA 4X, marine enviroments

    High power factor ballasts (+90%) arestandard, which allow more luminairesper circuit

    Standard Materials: Luminaire housing and door frame

    assembly copper-free aluminum External hardware stainless steel Lens heat- and impact-resistant

    refractor style glass Gaskets silicon rubber Reflector aluminum light sheet Wire guard stainless steel

    Standard Finishes: Aluminum Corro-free epoxy powder coat Stainless steel natural

    Certifications andCompliances: NEC/CEC:

    Class I, Division 2, Groups A, B, C, DClass II, Class III & SimultaneousPresence(Class I, Division 2 and Class II)Class I, Zone 2

    IEC:Zone 2 Ex nR IIC

    UL Standards:844, 2279 Hazardous (Classified)Locations1598 Luminaires1598A Marine Locations

    CSA Standards:C22.2 No. 137

    IEC Standards:60079-15

    About the Battery: Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture

    Electrical Rating Ranges: 52 watts 120277V, 5060 Hz 120V, 60 Hz 347V, 60 Hz

    Options:Description SuffixRestricted breathing construction................................................................................. S826

    Class I, Division 2 & Zone 2 suitabilityCooler operating temperatures (T-numbers)

    Certified for IEC Zone 2 (Suffix S826TB)....................................................................... S826TBFurnished with:Terminal BlockCrimp TerminalsDedicated voltage ballasts (no MT, DT or TT)

    Factory assembled with lamp installed......................................................................... FAFused - projects ballast and capacitors against abnormal line conditions.................. S658

    (Not for use in Canada)(Not for Marine use)

    Accessories:Description Cat. #Stainless steel wire guard............................................................................................. P55

    *Consult Cooper Crouse-Hinds.

    1154-1155.qxp 5/30/2011 11:16 AM Page 1155

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1156

    10L

    10L CPMVFB EmergencyCompact FluorescentContinuous OperationChamp-Pak Luminaires

    Ordering InformationDimensions & Weights

    Ordering Information:

    Hub SizeLampWatts

    Cat. # for usewith ANSI Lamps

    3/4 NPT 26 CPMVFB2W026

    DimensionsIn Inches:

    Net Weights:Luminaire Less Guard 18.6 lbs.P55 Guard 0.5 lbs.

    Standard Voltage BallastsNEC/UL CEC/CSA (cUL)

    Voltage 120277V 5060 Hz 120V/60 Hz 347V 60 HzSuffix /UNV /120CAN /347

    1156-1157.qxp 5/30/2011 11:16 AM Page 1156

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1149

    10L10LDMVF(B) Exit Sign

    Fluorescent LuminaireCl. I, Div. 2; Groups A, B, C, DRestricted Breathing Cl. I,Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)

    Cl. II, Groups E, F, G,Cl. III & Simultaneous PresenceMarine & Wet Locations3, 3R, 4X; IP66

    About the Battery: Bodine fluorescent battery pack ballasts

    are UL component recognized Sealed, maintenance-free, high

    temperature nickel cadmium Solid state chargers are sealed inside the

    ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During emergency use 1 lamp has

    continuous operation A red indicator light indicates the battery

    is charging Wiring instructions for a "Push-to-Test"

    button is supplied with the fixture

    Energy Savings: Less wattage used with compact

    fluorescent lamps compared toequivalent incandescent lamps providingthe same light output

    Standard Materials: Ballast housings and mountings copper-

    free aluminum (less than 0.4 of 1%) Exterior hardware stainless steel Globe heat- and impact-resistant

    internally fluted glass

    Standard Finishes: Aluminum gray epoxy powder coat Krydon material high reflectance white Stainless steel natural

    Electrical Rating Ranges: 52 Watt 120277V, 5060 Hz 120V, 60 Hz 347V, 60 Hz

    Options:Description Suffix Lamps supplied with exit sign............................................... S714Top hat with stainless steel threaded insert.......................... S806Restricted breathing construction.......................................... S826

    Class I, Division 2 & Zone 2 suitabilityCooler operating temperatures (T-Numbers)

    Certified for IEC Zone 2......................................................... S826TBFurnished with:Terminal BlockCrimp TerminalsDedicated voltage ballasts (no MT, DT or TT)

    Certifications andCompliances: NEC and CEC:

    Class I, Division 2, Groups A, B, C, DClass II, Class III & SimultaneousPresence(Class I, Division 2 and Class II)Class I, Zone 2

    IEC:Zone 2 Ex nR IIC

    UL Standards:844, 2279 Hazardous (Classified)Locations1598 Luminaires1598A Marine Luminaires

    CSA Standards:C22.2 No. 137

    IEC Standards:60079-15

    MountingType

    SupplyVoltageVolts/Hertz Fluorescent Cat. #

    Fluorescent withBattery Back-up Cat. #

    Pendant120277V / 5060 Hz DMVF2A052G/UNV EXD DMVFB2A052G/UNV EXD120V / 60 Hz (Canada) DMVFB2A052G/120CAN EXD347V / 60 Hz DMVF2A052G/347 EXD DMVFB2A052G/347 EXD

    Ceiling120277V / 5060 Hz DMVF2C052G/UNV EXD DMVFB2C052G/UNV EXD120V / 60 Hz (Canada) DMVFB2C052G/120CAN EXD347V / 60 Hz DMVF2C052G/347 EXD DMVFB2C052G/347 EXD

    Wall120277V / 5060 Hz DMVF2TW052G/UNV EXD DMVFB2TW052G/UNV EXD120V / 60 Hz (Canada) DMVFB2TW052G/120CAN EXD347V / 60 Hz DMVF2TW052G/347 EXD DMVFB2TW052G/347 EXD

    Ordering Information:

    Applications:DMVF(B) Exit Signs are used: In any building or enclosed area where

    people work Where illuminated exit signs are required To provide distinct, highly visible exit

    markings To indicate the direction of travel to exits In locations deemed hazardous due to

    the presence of flammable vapors orgases, or combustible dusts

    Features: Six inch letters on white glass sign panel

    make the word "exit" stand out boldlyand clearly

    Housings made of die-cast copper-freealuminum (less than 0.4 of 1% copper)for strength and resistance to corrosion

    Mounting module equipped with integralhub set-screws for vibration resistance(ceiling and pendant mounts)

    Hubs are provided with an integralconduit stop and bushing to help preventdamage to field wiring during installation

    Epoxy powder finish and stainless steelexternal hardware for resistance tocorrosion

    Long life gaskets which provide sealsbetween mounting module, housing, andglobe assembly

    Grounding wire for safety Cool operating design Optional emergency battery back-up

    operation during power outage

    1148-1149.qxp 5/30/2011 11:14 AM Page 1149

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1157

    10LDMVFB EmergencyCompact FluorescentContinuous OperationChamp Luminaires

    Cl. I, Div. 2, Groups A, B, C, DRestricted Breathing Cl. I,Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)

    Cl. II, Groups E, F, G; Cl. III &Simultaneous PresenceMarine & Wet Locations3, 3R, 4, 4X; IP66Emergency Lighting

    Applications:DMVF Series Champ Lighting Luminairesare used: Where emergency lighting is required to

    permit workers in industrial areas tosafely encounter their surroundingsduring power failures

    Where emergency egress lighting isrequired, such as: catwalks, walkways,tunnels, doorways, stairs, stairwells,ramps, and aisles

    In areas made hazardous by abnormalconditions resulting in the presence offlammable vapors or gases

    In areas made hazardous by thepresence of combustible dusts

    Where combustible dusts and flammablevapors are present simultaneously

    In marine applications where water sprayand corrosive atmospheres areconsiderations

    On installations where vibration andrough usage are problematic

    Where a cool, efficient light source is required

    In areas that require lamps to reach fullillumination immediately

    In refineries, chemical and petrochemicalfacilities, grain processing, handling orstorage facilities, manufacturing plants,wastewater treatment plants, sewagetreatment plants, oil terminals, foodprocessing facilities, breweries, and any other manufacturing or processingfacility where safe, reliable hazardousarea fluorescent or auxiliary lighting is needed

    Standard Features: Housings made of die-cast copper-free

    aluminum (less than 0.4 of 1% copper)for strength and resistance to corrosion

    Mounting modules equipped withintegral hub set-screws for vibrationresistance (ceiling, pendant, and quadmounts)

    Hubs are provided with an integralconduit stop and bushing to help preventdamage to field wiring during installation

    Epoxy powder finish and stainless steelexternal hardware for resistance tocorrosion

    Long-life gaskets which provide sealsbetween mounting module, housing,and optical assembly

    Grounding wire for safety Cool operating design Optional stainless steel open bottom

    guard permits direct access to the globefor easy relamping

    Battery pack ballast for emergencylighting

    Energy Savings Less wattage used with compact

    fluorescent lamps compared toequivalent incandescent lampsproviding the same light output

    About the Battery (DMVFB Units): Bodine fluorescent battery pack ballasts

    are UL component recognized Sealed, maintenance-free, high

    temperature nickel cadmium Solid state chargers are sealed inside

    the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has

    continuous operation A red indicator light indicates the battery

    is charging Wiring instructions for a "Push-to-Test"

    button is supplied with the fixture

    Standard Materials: Ballast housings and mountings copper-

    free aluminum (less than 0.4 of 1%) External hardware guards stainless steel Reflectors Krydon fiberglass-

    reinforced polyester material Globe heat- and impact-resistant

    internally fluted glass

    Standard Finishes: Aluminum gray epoxy powder coat Krydon material high reflectance white Stainless steel natural

    Electrical Rating Ranges: 52, 64, and 84 watts 120277V, 5060 Hz 347V, 60 Hz

    Certifications andCompliances: NEC/CEC:

    Class I, Division 2, Groups A, B, C, DClass II, Class III & Simultaneous Presence (Class I,Division 2 and Class II)Class I, Zone 2Emergency Lighting

    IEC:Zone 2 Ex nR IIC

    UL Standards:844, 2279 Hazardous (Classified)Locations1598 Luminaires1598A Marine Locations924 Emergency Lighting

    CSA Standards:C22.2 No. 137

    IEC Standards:60079-15

    Options:Description Suffix Restricted breathing

    construction................................ S826-Class I, Division 2 & Zone 2 suitability-Cooler operating temperatures(T-numbers)

    Certified for IEC Zone 2............. S826TB-Furnished with:Terminal BlockCrimp Terminals

    Emergency operation only Consult Cooper-Hinds

    Factory assembled with lampinstalled....................................... FA

    Fused to protect ballastagainst abnormal line conditions(not for use in Canada) (not formarine use).................................. S658

    Lamps supplied with luminaire... S714 Top hat with stainless steel

    threaded insert to attach ballasthousing........................................ S806

    TEFLON coating on globe forincreased shatter protection....... S808

    Accessories:(Order separately)Description Cat. #

    Dome RD73930 Angle RA739

    10L

    1156-1157.qxp 5/30/2011 11:16 AM Page 1157

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1158

    10L

    10L

    MountingStyle

    HubSize (In.)

    LampWatts

    DMVFB SeriesFluorescent with BatteryBack-Up with G303 Globeand P33 GuardCat. #

    Pendant Mount 3/4 52 DMVFB2A052GP1 DMVFB3A052GP3/4 64 DMVFB2A064GP1 DMVFB3A064GP3/4 84 DMVFB2A084GP1 DMVFB3A084GP

    Flexible PendantMount

    3/4 52 DMVFB2HA052GP3/4 64 DMVFB2HA064GP3/4 84 DMVFB2HA084GP

    Ceiling MountThru-Feed

    3/4 52 DMVFB2C052GP1 DMVFB3C052GP3/4 64 DMVFB2C064GP1 DMVFB3C064GP3/4 84 DMVFB2C084GP1 DMVFB3C084GP

    Wall MountThru-Feed

    3/4 52 DMVFB2TW052GP1 DMVFB3TW052GP3/4 64 DMVFB2TW064GP1 DMVFB3TW064GP3/4 84 DMVFB2TW084GP1 DMVFB3TW084GP

    Quad-Mount 3/4 52 DMVFB25Q052GPPendant, AdjustableThru-Feed, 25 Angle,121/2 Angle

    3/4 64 DMVFB25Q064GP3/4 84 DMVFB25Q084GP

    Stanchion Mount 11/2 52 DMVFBJ052GP25 Angle 11/2 64 DMVFBJ064GP

    11/2 84 DMVFBJ084GP

    Stanchion Mount 11/2 52 DMVFBP052GPStraight 11/2 64 DMVFBP064GP

    11/2 84 DMVFBP084GP

    1. Catalog numbers are basic numbers. Voltage must be specified.

    Standard Voltage Ballasts

    NEC/UL CEC/CSA (cUL)

    1. Voltage 120277V 5060 Hz 120V/60 Hz 347V 60 HzSuffix /UNV /120CAN /347

    Note: For technical information on familytrees, temperature performance data,dimensions, weights, and photometrics,refer to Series in Section 6L.

    DMVFB EmergencyCompact FluorescentContinuous OperationChamp Luminaires

    Cl. I, Div. 2, Groups A, B, C, DRestricted Breathing Cl. I,Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)

    Cl. II, Groups E, F, G; Cl. III &Simultaneous PresenceMarine & Wet Locations3, 3R, 4, 4X; IP66Emergency Lighting

    1158-1159.qxp 5/30/2011 11:17 AM Page 1158

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1148

    10L

    EVLPF(B) Exit SignFluorescent Luminaire

    Cl. I, Div. 1, Groups B (suffix GB), C, DCl. I, Zone 1, Groups IIB + H2(GB suffix), IIBCl. II, Div. 1, Groups E, F, G; Class III,Simultaneous Presence

    Marine & WetLocations3, 3R, 4, 4X;IP66

    Applications:EVLPF(B)-EXD Exit Signs are used: In any building or enclosed area where

    people work where illuminated exitsigns are required

    To provide distinct, highly visible exitmarking

    To indicate the direction of travel to exits In locations deemed hazardous due to

    the presence of flammable vapors,gases, or combustible dusts

    Features and Benefits: Six inch red letters on white glass sign

    panel make the word "EXIT" stand outboldly and clearly

    Lightweight copper-free aluminumhousing with powdered epoxy finish

    All exterior hardware is corrosion-resistant stainless steel

    Three mounting arrangements: pendant,ceiling, and wall bracket

    Integral ballast High power factor (90%+) ballasts Easier assembly, installation, and

    maintenance Outdoor, hose down, marine and

    corrosive environments suitable Ideal for adverse environments typical of

    industrial facilities Ground wire for safety Optional battery back-up for operation

    during power outage

    About the Battery: Bodine fluorescent battery pack ballasts

    are UL component recognized Sealed, maintenance-free, high

    temperature nickel cadmium Solid state chargers are sealed inside

    the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During emergency use 1 lamp has

    continuous operation Red indicator light indicates the battery

    is charging Wiring instructions for a "Push-to-Test"

    button is supplied with the luminaire

    Standard Materials: Mounting modules, cover, ballast

    housing, globe holder copper-freealuminum

    Globe heat- and impact-resistant glass Exterior hardware stainless steel

    Standard Finishes: Copper-free aluminum Corro-free

    powdered epoxy

    Ratings (Electrical/Size):Sources/wattage: 52W (2-26W lamps) 120-277V, 50-60 Hz 120V, 60 Hz 347V, 60 HzConduit entries: 3/4", 1" NPT pendant, wall bracket,

    ceiling

    Certifications andCompliances: NEC and CEC:

    Class I, Division 1, Groups B (GBsuffix), C, DClass I, Zone 1, Groups IIB + H2 (GBSuffix), IIB, IIAClass II, Class III & SimultaneousPresence (Class I and Class II)

    UL Standards:844 Hazardous (Classified) Locations1598 Luminaires1598A Marine Locations

    CSA Standards:C22.2 No. 137

    Options:Description Suffix Group B suitability GBFactory assembled with lamps FA

    10L

    Energy Savings: Less wattage used with compact

    fluorescent lamps compared toequivalent incandescent lamps providingthe same light output

    Ordering Information:

    MountingType

    SupplyVoltageVolts/Hertz Fluorescent Cat. #

    Fluorescent withBattery Back-up Cat. #

    Pendant120277V / 5060 Hz EVLPFA02520/UNV EXD EVLPFBA02520/UNV EXD120V / 60 Hz (Canada) EVLPFBA02520/120CAN EXD347V / 60 Hz EVLPFA02520/347 EXD EVLPFBA02520/347 EXD

    Ceiling120277V / 5060 Hz EVLPFCX02520/UNV EXD EVLPFBCX02520/UNV EXD120V / 60 Hz (Canada) EVLPFBCX02520/120CAN EXD347V / 60 Hz EVLPFCX02520/347 EXD EVLPFBCX02520/347 EXD

    Wall120277V / 5060 Hz EVLPFBX02520/UNV EXD EVLPFBBX02520/UNV EXD120V / 60 Hz (Canada) EVLPFBBX02520/120CAN EXD347V / 60 Hz EVLPFBX02520/347 EXD EVLPFBBX02520/347 EXD

    1148-1149.qxp 5/30/2011 11:14 AM Page 1148

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1159

    10LEVLPFB EmergencyCompact FluorescentContinuous OperationLow Profile Luminaires

    Cl. I, Div. 1, Groups B (GB Suffix), C, DCl. I, Zone 1, Groups IIB + H2(GB suffix), IIB, IIACl. II, Div. 1, Groups E, F, G; Class III,Simultaneous Presence

    Marine & WetLocations3, 3R, 4, 4X; IP66Emergency Lighting

    Applications:Cooper Crouse-Hinds Low ProfileHazardGard Luminaires are used in: Areas that require lamps to reach full

    lumination immediately Where emergency lighting is required to

    permit workers in industrial areas tosafely encounter their surroundingsduring power failures

    Where emergency lighting is requiredsuch as: catwalks, walkways, tunnels,doorways, stairs, stairwells, ramps, andaisles

    Areas where flammable or explosivevapors or gases are present

    Hazardous areas, both indoors andoutdoors, where long life and lowmaintenance costs are desired

    Petroleum refineries, chemical,petrochemical and pharmaceuticalplants, oil terminals, gas plants andother heavy process industry facilities

    Waste treatment facilities Drilling platforms and other coastal and

    offshore hazardous areas

    Features and Benefits: Small, compact size Two start Acme threaded construction Easier assembly, installation, and

    maintenance Lightweight copper-free aluminum

    housing with powdered epoxy finish All exterior hardware is corrosion-

    resistant stainless steel Four mounting arrangements: pendant,

    ceiling, wall bracket, and stanchion Integral ballast High power factor (90%+) ballasts Uses same mounting modules as the

    standard HazardGard Internally fluted glass globes Krydon construction dome and angle

    reflectors won't rust, corrode, dent,chip, or peel

    Now available in components luminairebody, mounting module, guard,reflectors

    Three wire construction For energy conservation, luminaires can

    be switched off without affecting theemergency operation feature

    Standard Materials: Mounting modules, cover, ballast

    housing, globe holder copper-freealuminum

    Globe heat- and impact-resistant glass Exterior hardware stainless steel Reflectors (dome & angle) Krydon

    fiberglass-reinforced polyester

    Standard Finishes: Copper-free aluminum Corro-free

    powdered epoxy Krydon white Stainless steel guard

    Energy Savings Less wattage used with compact

    fluorescent lamps compared toequivalent incandescent lamps providingthe same light output

    Ratings (Electrical/Size):Sources/Wattage: Fluorescent continuous operation

    emergency lighting 52W (2-26W lamps)and 64W (2-32W lamps) compactfluorescent voltages

    Fluorescent emergency lighting120277V, 5060 Hz120V, 60 Hz347V 60Hz

    Conduit entries: 3/4", 1" NPT pendant, wall bracket,

    ceiling 11/4" NPT stanchion

    Certifications andCompliances: NEC/CEC:

    Class I, Division 1, Groups B (with GB suffix), C, DClass I, Zone 1, Groups IIB + H2(GB Suffix), IIB, IIAClass II, Class III & SimultaneousPresence(Class I and Class II)Emergency Lighting

    UL Standards:844 Hazardous (Classified) Locations1598 Luminaires1598A Marine Locations924 Emergency Lighting

    CSA Standards:C22.2 No. 137

    Options:Description SuffixGroup B suitability GBFused (not for use in Canada) (not for marine use) S658*Factory assembled with lamps FAEmergency operation only Consult Cooper Crouse-Hinds*When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot beordered with /MT in the catalog number.

    Accessories:Description Cat. #

    Dome reflector RD739Angle reflector RA739

    About the Battery: Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case; 90 minute illumination time; 10-year

    life expectancy 2-year warranty During emergency use, 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture

    10L

    1158-1159.qxp 5/30/2011 11:17 AM Page 1159

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1160

    10L

    10L EVLPFB EmergencyCompact FluorescentContinuous OperationLow Profile Luminaires

    Cl. I, Div. 1, Groups B (GB Suffix), C, DCl. I, Zone 1, Groups IIB + H2(GB suffix), IIB, IIACl. II, Div. 1, Groups E, F, G; Class III,Simultaneous Presence

    Marine & WetLocations3, 3R, 4, 4X; IP66Emergency Lighting

    Pendant Mount

    Wall Bracket Mount

    Ceiling Mount

    Stanchion Mount

    Ceiling and bracket mounts have 4 hubs: 3 are plugged.

    Complete Catalog Numbers as follows:Standard Voltage Ballasts

    NEC/UL CEC/CSA (cUL)1. Voltage 120277V 5060 Hz 120V/60 Hz 347V 60 Hz

    Suffix /UNV /120CAN /347

    Example: EVLPFB02521/UNV2. Other Voltages Consult Cooper Crouse-Hinds

    Note: For technical information on family trees, temperature performance data, dimensions,weights, and photometrics, refer to DMVF Series in Section 6L.

    EVFPFB Fluorescent Emergency Lighting Three wire construction, for switching purposes, is standard on fluorescent emergency lighting. For energy conservation, luminaires can be switched off without affecting the emergency operation

    feature.

    *Test switch is remote mounted.Use Cooper Crouse-Hinds EDSC218 (Not furnished).

    Ordering Information:

    Pendant Wall Bracket Ceiling Stanchion

    LuminaireBodyLessMountingModule &Guard

    Watt

    HubSize(In.)

    With GuardCat. #

    With GuardCat. #

    With GuardCat. #

    With GuardCat. # Cat. #

    Fluorescent with Emergency Ballast High Power Factor Ballast (Min. P.F. 90%)

    52W

    3/4 EVLPFBA02521 EVLPFBBX02521 EVLPFBCX02521 EVLPFB05201 EVLPFBA03521 EVLPFBBX03521 EVLPFBCX0352111/4 EVLPFBJ04521

    64W3/4 EVLPFBA02641 EVLPFBBX02641 EVLPFBCX02641 EVLPFB06401 EVLPFBA03641 EVLPFBBX03641 EVLPFBCX0364111/4 EVLPFBJ04641

    1160-1161.qxp 5/30/2011 11:17 AM Page 1160

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1146

    10L

    EXL Explosionproof Exit Sign

    Factory-sealed

    Cl. I, Div. 1 & 2, Groups C, DCl. I, Zone 1 IIBCl. II, Div. 1, Groups E, F, G

    Applications:EXL Exit Signs are used: In locations deemed hazardous due to

    the presence of flammable vapors orgases, or combustible dusts

    In any building or enclosed area wherepeople work where illuminated exitsigns are required

    To provide distinct, highly visible exitmarking

    To indicate the direction of travel to exits

    Features: Two incandescent lamps (not included)

    wired in parallel to provide extramargin of light source reliability

    Solid state circuit for extended lamp lifein AC units

    Six inch red letters on white acrylic signpanel make word "exit" stand out boldlyand clearly

    Edge lighting characteristic of sign panelmakes visibility excellent at all lightinglevels

    Factory-sealed explosionproof housing Pendant, wall, and end bracket mounts

    provide universal installation options Impact-resistant acrylic sign panel needs

    no guard makes cleaning easy Internal rectifier extends lamp life

    beyond 1,000-hour rated life reducesrelamping cost

    Relamping tool provided

    Standard Materials: Body copper-free aluminum Sign panel acrylic

    Conduit Entrance: 3/4" hubs

    Lamp Wattage: Two 60 watt, 60T10 clear lamps for AC units Two 25 watt, 25T10 clear lamps for DC units Lamps not included with luminaire

    Electrical Ratings: 120VDC or 120VAC operation

    Certifications andCompliances: NEC:

    Class I, Groups C, DClass II, Groups E, F, G

    UL Standard: 844 NFPA Life Safety Code No. 101-1991

    Ordering Information:When ordering an EXL Series Exit Sign,you will need to specify:

    (A) Voltage (120VAC or 120VDC)(B) Mounting (Wall, End Bracket, or

    Pendant)(C) Exit Sign Designation

    All units come standard with 3/4" hubs andexit signs with red lettering and whitebackground. Complete catalog numberingis as follows:

    EXL (A) 2 (B) (C)(A) Voltage: 120VAC............ leave blank

    120VDC .......................... D(B) Mounting: Wall................................. 1

    End Bracket.................... 2Pendant .......................... 3

    (C) Exit Sign Designation:A Single Face (Wall Mount)AA Double Face (End Bracket

    & Pendant)AB Double Face, one side

    arrowhead right, the otherno arrowhead (End Bracket& Pendant)

    AC Double Face, one sidearrowhead left, the other noarrowheads (End Bracket &Pendant)

    AD Double Face, one sidearrowhead both ends, theother no arrowheads (EndBracket & Pendant)

    B Single Face, arrowheadright (Wall Mount)

    BC Double Face, one sidearrowhead right, the otherarrowhead left (End Bracket& Pendant)

    BD Double Face, one sidearrowhead both ends, theother arrowhead right (EndBracket & Pendant)

    C Single Face, arrowhead left(Wall Mount)

    CD Double Face, one sidearrowhead both ends, theother arrowhead left (EndBracket & Pendant)

    D Single Face, arrowheadboth ends (Wall Mount)

    DD Double Face, both sidesarrowhead both ends (EndBracket & Pendant)

    10L

    Pendant Style

    End Bracket Style

    Wall Style

    MountingType

    Sign PanelDescription

    HubSize (In.)

    ACCat. #

    DCCat. #

    Wall Single face 3/4 EXL21A EXLD21AEnd Bracket Double face 3/4 EXL22AA EXLD22AAPendant Double face 3/4 EXL23AA EXLD23AA

    Options:Description Suffix Exit signs with green lettering on white background........................................................ GNUnit provided with epoxy powder coat............................................................................. S752277VAC (Order ECT413 Transformer Separately)

    Temperature PerformanceData:(for both AC & DC operation):AmbientTemp. (C)

    Class I (C, D)Class II (E, F, G)

    SupplyWire C

    25 T3C 150C40 T3C

    1146-1147.qxp 5/30/2011 11:14 AM Page 1146

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1147

    10L10LEXL Explosionproof Exit Sign

    Factory-sealedDimensions

    Pendant Style Wall Style

    End Bracket Style

    DimensionsIn Inches:

    1146-1147.qxp 5/30/2011 11:14 AM Page 1147

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds 1161

    10L

    Ex-Lite LED Exit Signs Cl. I, Div. 2, Groups A, B, C, DCl. I, Zone 1, AEx em ib IIC (NEC)Cl. I, Zone 1, Ex em ib IIC (CEC)Cl. II, Div. 2, Groups F, G (NEC)Cl. II, Div. 2, Groups E, F, G (CEC)

    UL ListedIP66

    The Ex-Lite Series of LED exit signs aredesigned for hazardous locations and areideally suited for marking escape routesand exits in potentially explosiveatmospheres.

    The Ex-Lite Z is available as an AC onlyversion, while the Ex-Lite ZE is availablewith self-contained battery. As anemergency lighting luminaire with self-contained battery system, the Ex-Lite ZEfeatures a nickel cadmium battery withautomatic test and monitoring feature.

    Applications: In harsh and hazardous environments

    where illuminated exit signs are required

    Features and Benefits:LED Technology: Long life (>50K hours) for years of

    maintenance-free operation Energy-efficient for lower cost of

    operation Low temperature operation with no loss

    of illumination Rugged and durable light source for the

    harshest of environmentsExit Sign System: Can be used in a hazardous location Conduit or cable entry Can be installed in moist, humid, rain,

    and wet environments Universal input voltage 110VAC-277VAC

    and 110VDC-250VDC reduces inventory Ex-Lite ZE with self-monitoring, self-

    diagnostic, and test capability Premium heavy-duty nickel cadmium

    battery 24-hour charge and recharge time

    increases safety by recovering quicklyfrom outage

    "EXIT" legend with alternative wings -left, right, or left and right; simple fieldmodification

    Emergency lighting cycle three hours The housing of the luminaire is

    constructed with a corrosion resistant,robust, lightweight aluminum alloymaterial and illumination of the sign isprovided with red, high-efficient LEDs

    Certifications andCompliances: Class I, Division 2, Groups A, B, C, D Class I, Zone 1, AEx em ib IIC (NEC) Class I, Zone 1, Ex em ib IIC (CEC) Class II, Division 2, Groups F, G (NEC) Class II, Division 2, Groups E, F, G

    (CEC) IP66 UL844 UL924/CSA22.2 No. 141-02 UL60079/CSA22.2 E60079 UL1203/CSA22.2 E6124-1-1-02

    DimensionsIn (mm):

    10L

    Ordering Information:Catalog Number Ex Lite Z Ex Lite ZE

    Description AC/DC Exit Sign with Battery

    Light Source LED LEDLife of LED 50K hours 50K hoursRated Voltage, VAC 120V-277V 120V-277VFrequency, Hz 50/60 50/60Rated Voltage, DC 110V-250V 110V-250VPower Consumption 6VA 6VABattery N/A NiCad

    Allowable Temperature Range -4F to 122F(-20C to 50C)41F to 95F(5C to 35C)*

    Mounting Wall WallCable Entry Ex-e Ex-eConduit Entry 3/4" 3/4"Protection IP66 IP66

    *Due to battery chemistry, the charging capacity will be limited at temperatures below 5C and above 35C.

    Material Number 12191001005 12191130005

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1150

    10L

    10L ELPS Light-PakEmergency LightingSystem

    Cl. I, Div. 1 & 2, Groups C, DCl. I, Div. 1 & 2, Groups B, C, D(with suffix GB)Cl. II, Div. 1, Groups E, F, GCl. III

    Cl. I, Zone 1Simultaneous PresenceWet LocationsNEMA 3, 3R, 12

    Applications:ELPS Series Emergency Lighting Systemsare used: To provide safe, reliable illumination

    indoors or outdoors to designated areasduring failure or interruption of power tothe normal lighting system

    In areas made hazardous by thepresence of flammable gases andvapors, combustible dusts, or easilyignitible fibers and flyings

    In areas where corrosion, vibration,moisture, dirt, and rough usage may beencountered

    Where required by the National ElectricalCode, the Life Safety Code, or othercodes

    In refineries, chemical and petrochemicalfacilities, grain processing, handling orstorage facilities, manufacturing plants,wastewater treatment facilities, andother areas where safe, reliable,hazardous area emergency lighting isneeded

    Features: Compact factory-sealed luminaire

    assemblies are each furnished with a 12watt tungsten-halogen lamp and innerreflector for appropriate photometrics inhazardous areas

    Luminaire assemblies are fully adjustableand lockable on two axes to provideflexible and consistent light aimingcapabilities

    Luminaire lens ring is threaded for easyrelamping and locks in place with hexhead set-screw; will not loosen due tovibration

    Ground joint cover with external flangedesign permits large opening and easyaccess to internal components; studbolts in diagonally opposite corners ofbody ease cover removal and installation

    Neoprene cover gasket seals outmoisture for superior protection ofinternal components against wetnessand corrosion

    Lightweight, compact size, andmounting feet ease installation and allowplacement in confined areas

    Two 1" NPT drilled and tapped conduitopenings, with plugs, are standard, forchoice of top or bottom feed

    Factory-installed PUSH-TO-TESTpushbutton enables easy testing ofsystem

    MAIN POWER ON pilot light indicatesAC power is being supplied to thebattery charger; pilot light jewel isthreaded for easy lamp replacement

    Stainless steel drain minimizes moisturecollection; stainless steel breather withaluminum cap provides ventilation,minimizes moisture collection

    CID 101 corrosion inhibitor device isprovided with each ELPS system to helpprotect electrical components andconnections

    Rugged, long-life, maintenance-free,nickel cadmium battery provides 30watts of power for the required 11/2 hours

    Solid state battery charger for long lifeand reliable service prevents deepdischarge by automaticallydisconnecting luminaires from battery Electrical Ratings:

    Power Supply:Input:

    120, 220/240, 277 VAC, 50 or 60 Hz0.5 Amps Maximum

    Output: 12 VDCUL listed for 28 watts for 11/2 hours at 0 40C

    Luminaires:Voltage: 12 VDCLamp Type: #789, miniatureTungsten halogen, G4, 2-pin, 14 watt

    Standard Materials: Power supply enclosure and luminaire

    assembly copper-free aluminum (lessthan 0.4 of 1% copper)

    Standard Finishes: Power supply enclosure and fixture

    assemblies powder coat epoxy paintfinish

    Options:Description Suffix Remote mounted lamp head and arm....EVLA12 Key operated disconnect switch

    as part of the ELPS502 emergency light system .......................... S794

    Keyless operated designateddisconnect switch as part of theELPS502 emergency light system .......... S854

    Ordering Information:Description Cat. #

    Standard unit withadjustable heads............ ELPS502

    Replacement powerinterior, includes circuitboard and battery pack ELPS K50

    Power supply ................. ELPS50 Lamphead and arm ....... EVLA12 Exit sign, double sided

    with EVI, red letters........ ELPS502 EXD Exit sign, double sided

    with EVI, green letters.... ELPS502 EXD GN Exit sign, single or

    double sided withGroup B EVA, red letters....................... ELPS502 EXD GB

    Exit sign, single ordouble sided withGroup B EVA, greenletters ............................. ELPS502 EXD GB GN

    Exit sign, single sidedwith EVI, red letters........ ELPS502 EXS

    Exit sign, single sided with EVI, green letters................... ELPS502 EXS GN

    Base unit comes standard with Class I, Division 1, Group B.

    Certifications andCompliances: NEC:

    Class I, Groups B, C, DClass II, Groups E, F, GClass IIISimultaneous Presence

    NEMA: 3R, 12 (ELPS power supply) Suitable for wet locations (EVLA fixtures) Marine (EVLA fixtures) UL Standard:

    844 Electric Luminaire HazardousLocations924 Emergency Lighting and PowerEquipment1203 Explosionproof and Dust-Ignitionproof Electrical Equipment

    Life Safety Code:Section 5-9 (Emergency Lighting)

    Suitable for Wet Locations NEMA 3, 3R, 12 Marine

    Terminal block facilitates field wiringconnections

    Instruction sheet and maintenancerecord card provided with unit in aprotective plastic envelope

    A time delay is standard; time delay ispreset at factory for 5 minute delay butcan be field set for 5 seconds or 15minutes, thus allowing HID type lampstime to restrike and reach desiredillumination levels

    Solid state battery charger will accept120, 220/240 or 277 VAC, 50/60 Hz

    1150-1151.qxp 5/30/2011 11:15 AM Page 1150

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1151

    10LELPS Light-PakEmergency Lighting System

    Temperature Performance DataPhotometric DataDimensions and Weights

    Temperature Performance Data:Cat. # Class T-numberMaximum Ambient Temperature 55C

    EVLA12I T4AII* T3BIII* T3B

    Maximum Ambient Temperature 40C

    ELPS EVI T3CT4

    ELPS EVA T3CT4*For Class II and Class III applications, fixtures must not be aimed more than 30 abovehorizontal (see diagram below).

    Photometric Data:

    Unit Net Weights: ELPS502 complete emergency lighting system 50 lbs. ELPS50 power supply 40 lbs. EVLA12 luminaire assembly 5 lbs.

    Status Indication:LED Status Condition Meaning of the Indication

    No light AC power is removed from the circuit

    Steady light (no blinking) Fully charged

    Light blinks once Charging

    Light blinks twice Battery failure

    Light blinks three times Circuit failure Light blinks four times Lamp failure

    10L

    DimensionsIn Inches:

    1150-1151.qxp 5/30/2011 11:15 AM Page 1151

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds1152

    10L

    LED N2LPS LIGHT-PAKEmergency Lighting System

    Cl. I, Div. 2, Groups B, C, DCl. I, Zone 2Wet Locations, MarineNEMA 3, 3R, 4XAmbient 0C to 55C

    Applications:LED N2LPS Light-Pak emergency lightingsystems are used: To provide reliable illumination for

    egress areas during failure orinterruption of power to the normallighting system

    In areas where flammable gases orvapors may become present due toabnormal, unusual, or accidentalconditions

    In manufacturing plants, refineries,petrochemical and chemical plants,waste and sewage treatment facilities,oil terminals, food processing facilities,breweries, and other industrialmanufacturing or process industryfacilities subject to wet or corrosiveconditions

    To illuminate machinery or panels duringa loss of AC power

    Where moisture, dirt, dust, or corrosionwill limit the life and reliability of ordinaryemergency lighting systems

    Where required by the NationalElectrical Code, the Life Safety Codeor other applicable codes

    Outdoor applications

    Features: Compact, factory-assembled luminaire

    featuring LED lamps for improved lumenperformance, on-time, and lamp life

    Nonmetallic, enclosed, and gasketedhousing provides corrosion protection inthe most extreme environments

    Durable and marine rated LED lamphead assemblies provide protectionagainst water ingress, corrosion, andimpact

    High temperature rated nickel cadmiumbattery for reliable operation up to 55Cambient

    Solid state battery charger for long lifeand reliable battery operation preventsdeep discharge by automaticallydisconnecting the battery from theluminaire

    Factory-installed "push-to-test" button Self-test, monitoring, and diagnostics

    reduce costly maintenance checks Remote luminaire head assemblies (one

    or two) are available for mounting ofluminaire heads away from main powersystem

    Stainless steel drain minimizes moisturecollection

    Standard battery disconnect switch(Krydon unit)

    Temperature PerformanceData:Based on 55C ambientCat. # Class I, Division 2

    N2LPS (all) 40C - T5; 55C - T4AN2RF (all) T5Note: Ambient temperature at which the Light-Pak

    system is rated is 0C to 55C. Operation attemperatures outside this range will affect thebattery life and/or charging performance.

    National Electrical Code and Life Safety Code areregistered trademarks of the National Fire ProtectionAssociation, Inc.Noryl is a registered trademark of General ElectricCompany.

    Standard Materials: Power supply and remote luminaire

    enclosures Krydon fiberglass-reinforced polyester

    LED lamp head assembly epoxypowder coated stainless steel

    Exterior hardware nylon, plasticcoated, and stainless steel

    Cover gasket Hypalon synthetic rubber

    Electrical Ratings: Power supply

    Input: 120, 220, 230, 240, or 277 VAC,50 or 60 Hz; 28 watts max.Output: 12 VDC

    Luminaire heads Voltage: 12 VDC; Lamp: 3 watt LEDTotal lumen output: 80

    Certifications andCompliances:NEC/CEC: Class I, Division 2, Groups B, C, D,

    Zone 2UL Standards: 1598A (Supplemental Requirements for

    Luminaires for Installation on MarineVessels)

    924 (Emergency Lighting and PowerEquipment)

    844 (Electric Luminaires HazardousLocations)

    CSA Standards: C22.2 No. 141-M1985 unit equipment

    for emergency lighting C22.2 No. 137-M1981 non-incendive

    electrical equipment for use in Class I,Division 2 hazardous locations

    Life Safety Code NFPA101 Section 5-9 (Emergency Lighting)

    Marine wet locations suitability, Type 4X

    Unit Net Weights: N2LPS12222 16 lbs. N2LPS12220 12 lbs. N2RF1221 8 lbs. N2RF1222 9 lbs.

    10L

    Note: Battery time in emergency mode is 90 minutes.

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1153

    10LCl. I, Div. 2, Groups B, C, DCl. I, Zone 2Wet Locations, MarineNEMA 3, 3R, 4XAmbient 0C to 55C

    Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can beconnected to the N2LPS12220.

    Wire Sizing for Remote Installation:For Copper Wire Running Distance (ft.) Between Power Supply and Remote Luminaire

    Load In Watts Load In Watts

    Wire Size 8 16 24 32 Wire Size 8 16 24 32

    16 AWG 26 13 6 3 10 AWG 106 53 26 1314 AWG 42 21 10 5 8 AWG 168 84 42 2112 AWG 66 33 16 8 6 AWG 270 135 67 33Maximum distance to limit line voltage drop to 5%.

    Dimensions (N2LPS):

    16.0

    13.5

    18.0

    7.5

    14.513.8

    5.0

    1.1

    7.4

    Standard N2LPS LED Light-Pak

    LED N2LPS LIGHT-PAKEmergency Lighting System

    10L

    Ordering Information:Description Cat. #

    28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads N2LPS1222228 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads N2LPS12222 SS28 watt, 12 volt power supply assembly less luminaire heads N2LPS12220*Remote luminaire assembly with one 3 watt LED lamp head N2RF1221*Remote luminaire assembly with two 3 watt LED lamp heads N2RF1222*28 watt, 120V LED Light-Pak with single sided exit sign** N2LPS12222/120 EXS DR039173428 watt, 277V LED Light-Pak with single sided exit sign** N2LPS12222/277 EXS DR039173428 watt, 120V LED Light-Pak with double sided exit sign** N2LPS12222/120 EXD DR039173428 watt, 277V LED Light-Pak with double sided exit sign** N2LPS12222/277 EXD DR0391734*Not cUL approved. UL Listed only.**Exit sign operates in both normal and emergency mode.

    1152-1153.qxp 5/30/2011 11:15 AM Page 1153

  • www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1154

    10L

    10L

    Dimensions (N2LPS):

    EXS, EXD Option N2LPS LED Light-Pak with Optional Emergency Exit Luminaire

    Dimensions (N2RF):

    11.77

    3.83

    9.50

    7.27

    3.83

    9.50

    4.38

    Detail Indication Logic:Status Indication Status Description Status Definition

    No Light AC Power Removed from Circuit* Steady Light (No Blinks) Fully Charged*-* Light Blinks Once Battery Charging**-** Light Blinks Twice Battery Failure***-*** Light Blinks Three Times Circuit Failure

    LED N2LPS LIGHT-PAKEmergency Lighting System

    Cl. I, Div. 2, Groups B, C, DCl. I, Zone 2Wet Locations, MarineNEMA 3, 3R, 4XAmbient 0C to 55C

    1154-1155.qxp 5/30/2011 11:16 AM Page 1154

    CPMVFB Fluorescent Emergency Luminaire.pdf11551156

    DMVFB Fluorescent Emergency Luminaire.pdf11571158

    EVLPFB Fluorescent Emergency Luminaire.pdf11591160

    EXL Incandescent Exit Sign.pdf11461147

    Light-Pak ELPS Emergency Lighting System.pdf11501151

    Light-Pak LED N2LPS_10L.pdf11531154