Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
7
97,1
1057
,5Ø 5,2 (2x)
R4
M5
3,3
8,3
5
R3
18,1
ReadheadCES-A-LSP-...
Dimensiondrawing
ReadheadCES-A-LSP-...M5 plug connector, 3-pin or hard-wire encapsulated cable
Active face
OptimizedforaluminumprofilemountingLEDfortheindicationofthedoorposition
Y
1520
2530
5
ZX
5
1520
2530
-20
-25
-30
-45
-50
-55-60
-65
-40
-35
-15
-10
-5
25
30
15
10
45
50
55
60
65
35
5
20
10
40
10
TypicaloperatingdistanceInstalled in aluminum profile 45 x 45 mm
Terminalassignment
H11 H12 SH1
BNWH
13
4
ScreenRead headCES-A-LSP
CES-AZ...
Connection cable see page 72
For possible combinations see page 24
Attention:The operating distance may vary de-pending on the background material and installation situation.
Important:Actuators must be ordered sepa-rately! See page 42.
Orderingtable
Series Cabletype/connectiontype/version Cablelength[m]/description Orderno./item
CES-A-LSP-...
VPVC cable
5 1049��CES-A-LSP-05V-104966
10 1049�7CES-A-LSP-10V-104967
15 10�271CES-A-LSP-15V-106271
20 10�272CES-A-LSP-20V-106272
25 1049�8CES-A-LSP-25V-104968
SBM5 plug connector - 1049�9
CES-A-LSP-SB-104969
InstallationmaterialforCES-A-LSP-...
For Bosch profiles with 8 mm groove 2 screws and 2 clamping pieces 10����Installation material 8-groove Bosch
For Bosch profiles with 10 mm groove 2 screws and 2 clamping pieces 10���4Installation material 10-groove Bosch
For ITEM profiles with 8 mm groove 2 screws and 2 clamping pieces 10���5Installation material 8-groove ITEM
With M5 plug connector
With connection cable
Mounting distanceCES-A-LSP-...
≤105
≤20
LED
��
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
CES
-AZ
TechnicaldatareadheadCES-A-LSP-...
Parameter Value Unit
min. typ. max.
Housing material Reinforced thermoplastic, fully encapsulated
Weight (without connection cable) 0.02 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
Connection M5 plug connector, 3-pin
LED indicator White, valid actuator detected
IncombinationwithactuatorCES-A-BSP-104970
Operating distance for center offset m = 0 1)
mm
with vertical approach direction (x direction)
- Assured switch-off distance Sar - - 45
Cable length l = 0 to 25 m
- Switch-on distance - 20 -
- Assured switch-on distance Sao 10 - -
- Switching hysteresis 1 4 -
Cable length - - 25 m
1) These values apply for the installation of the read head and the actuator in an aluminum profile 45 x 45 mm.
�4
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
25
42 ±0,
1
52,7
5,4
8
9
4,1
5,3
12
4,5
4,1 19
,4
4,6
32
ReadheadCES-A-LNN-...
Dimensiondrawing
ReadheadCES-A-LNN-...M8 plug connector, 3-pin or hard-wire encapsulated cable
Active face
Rectangulardesign42x25mmAttachmentcompatiblewithseriesCES-A-LNA/LCALEDfortheindicationofthedoorposition
Z
-25-30
X
105
1520
-20
-25
-30
-40
-35
-15
-10
-5
-10
20
25
30
15
10
40
35
5
Y
1015
2025
5-5
-15
-20
30
TypicaloperatingdistanceTerminalassignment
H11 H12 SH1
BNWH
14
3
Screen
Read head
CES-AZ...
For connection cable see page 69
For possible combinations see page 24
Attention:The operating distance may vary de-pending on the background material and installation situation.
Important:Actuators must be ordered sepa-rately! See page 43.
Orderingtable
Series Cabletype/connectiontype Cablelength[m] Orderno./item
CES-A-LNN-...
VPVC cable 5 10��02
CES-A-LNN-05V-106602
SCM8 plug connector - 10��01
CES-A-LNN-SC-106601
With M8 plug connector
With connection cable
Approachdirections
LEDActive face
Active face
For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm must be maintained so that the
operating distance of the side lobes is not entered.
2 safety screws M4x14 included
�5
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
CES
-AZ
TechnicaldatareadheadCES-A-LNN-...
Parameter Value Unit
min. typ. max.
Housing material Reinforced thermoplastic (PBT), fully encapsulated
Dimensions 42 x 25 x 12 mm
Weight (without connection cable) 0.025 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
Connection M8 plug connector, 3-pin or connection cable
LED indicator White, valid actuator detected
IncombinationwithactuatorCES-A-BBN-10��00
Operating distance for center offset m = 0 1)
mm
- Assured switch-off distance Sar in x/z direction - - 50
in y direction - - 80
Cable length l = 0 to 25 m
- Switch-on distance - 20 -
- Assured switch-on distance Sao 10 - -
- Switching hysteresis 1 4 -
IncombinationwithactuatorCES-A-BDN-0�-1047�0
Operating distance for center offset m = 0
mm
- Assured switch-off distance Sar in x/z direction - - 80
in y direction - - 50
Cable length l = 0 to 25 m
- Switch-on distance - 19 -
- Assured switch-on distance Sao 14 - -
- Switching hysteresis - 4 -
Cable length - - 25 m
1) These values apply for the surface installation of the read head and the actuator.
��
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
ReadheadCES-A-LC.../CES-A-LN...Rectangulardesign42x25mm
CES-
A-L
XXXX
XX
25
∅8
∅4,5
42
32±
0,1
12
4,6
"l"
ReadheadCES-A-LNA... (Fortron)Hard-wired encapsulated cable
Active face
Active face
5,5
∅10
6,8
∅8
∅4,5
4,6
12
25
min
.38
32±
0,1
4232
,6
A0
CES-
A-L
0777
15
3 41
ReadheadCES-A-LNA-SC (Fortron)M8 plug, 3-pin
Activeface
Active face
Orderingtable
Series Cabletype/connectiontype Cablelength[m] Version Orderno./item
CES-A-LCA-... VPVC cable 10 Housing material PE-HD 2) 088785
CES-A-LCA-10V
CES-A-LNA-...
VPVC cable
5 071845CES-A-LNA-05V
10 07184�CES-A-LNA-10V
15 071847CES-A-LNA-15V
25 071975CES-A-LNA-25V
PCable PUR
5 07780�CES-A-LNA-05P
10 077807CES-A-LNA-10P
15 084�82CES-A-LNA-15P
SCM8 plug connector - 077715 3)
CES-A-LNA-SC
CES-A-LNA-SC-EX SCM8 plug connector - ATEX 1) 09815� 1) 3)
CES-A-LNA-SC-EX
1) EX II 3G Ex nL IIC T70°C (zone 2 gases)2) Suitable for use in aggressive media (e. g. acids, alkalis)3) Plug connector suitable for snap-action and screw terminals
1)
TypicaloperatingdistanceTerminalassignment
32
4248
25
31
l
1214
4,6 ∅8
∅4,5
± 0
,1
Dimensiondrawing
ReadheadCES-A-LCA... (PE-HD)Hard-wired encapsulated cable
Active face
Activeface
Seal
X20
1510
5
2015
105
5
10
15
20
Y
Z
For a side approach direction for the actuator and read head, a minimum distance of s = 3 mm must be maintained so that the
operating distance of the side lobes is not entered.
H11 H12 SH1
BNWH
14
3
Screen
Read head
CES-AZ...
For connection cable see page 69
2 safety screws M4x14 included
2 safety screws M4x14 included
2 safety screws M4x14 included
For possible combinations see page 24
Attention:The operating distance may vary de-pending on the background material and installation situation.
Important:Actuators must be ordered sepa-rately! See page 45 and 47.
�7
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
CES
-AZ
Parameter Value Unit
min. typ. max.
Housing material- CES-A-LNA-... Fortron, reinforced thermoplastic, fully encapsulated
- CES-A-LCA-... Plastic PE-HD without reinforcement, fully encapsulated
Flat seal material (CES-A-LCA-... only) Fluororubber 75 FPM 4100
Dimensions 42 x 25 x 12 mm
Weight (incl. 10 m cable) 0.3 kg
Ambient temperature
°C- CES-A-LCA-... -25 - +50
- CES-A-LNA-.../CES-A-LNA-SC-EX -25 - +70
Degree of protection
- CES-A-LCA-... IP67
- CES-A-LNA-.../CES-A-LNA-SC-EX IP67/IP69K
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
IncombinationwithactuatorCES-A-BBA
Operating distance for center offset m = 0 1)
mm
- Assured switch-off distance Sar - - 26
Cable length l = 0 to 25 m
- Switch-on distance - 15 -
- Assured switch-on distance Sao 10 - -
- Switching hysteresis 0.5 2 -
Connection cable- CES-A-LCA-.../CES-A-LNA-...- CES-A-LNA-...
Hard-wired encapsulated connection cable, with crimped ferrulesPVC, ∅ 4.6 mm
PUR, ∅ 4.8 mm, suitable for drag chain
- CES-A-LNA-SC M8 plug connector (snap-action and screw terminals), 3-pin
Cable length See ordering table 25 m1) These values apply for surface installation of the read head and the actuator.
TechnicaldatareadheadCES-A-LC.../CES-A-LN...
�8
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
40 ±0,15
50 0,250
M8
40±
0,15
500,
250
20
7
6
20,2
Ø4,
5
-
x1
-
ReadheadCES-A-LQA-SC
Dimensiondrawing
ReadheadCES-A-LQA-SCM8 plug, 3-pin
Active face
Rectangulardesign50x50mmM8plugconnector(snap-actionandscrewterminals)
Orderingtable
Series Connection Comment Orderno./item
CES-A-LQA-SC SCM8 plug connector
2 safety screws M4 x 14 are supplied
095�50CES-A-LQA-SC
TypicaloperatingdistanceTerminalassignment
H11 H12 SH1
BNWH
14
3
Screen
Read head
CES-AZ...
For connection cable see page 69
For possible combinations see page 24
Attention:The operating distance may vary de-pending on the background material and installation situation.
Important:Actuators must be ordered sepa-rately! See page 46.
10
-30
2030
Z
Y
10
20
30
-30
30
20
10
X
With actuator CES-A-BBA or CES-A-BCA on evaluation unit CES-AZ
1020
30
Y
10
20
30
20
10
X 30Z
With actuator CES-A-BQA on evaluation unit CES-AZ
�9
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
CES
-AZ
TechnicaldatareadheadCES-A-LQA-SC
Parameter Value Unit
min. typ. max.
Housing material Fortron, reinforced thermoplastic, fully encapsulated
Dimensions 50 x 50 x 20.2 mm
Weight 0.08 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
IncombinationwithactuatorCES-A-BBAorCES-A-BCAonevaluationunitCES-AZ
Operating distance for center offset m = 0 1)
mm
- Assured switch-off distance Sar - - 47
Cable length l = 0 to 25 m
- Switch-on distance - 15 -
- Assured switch-on distance Sao 10 - -
- Switching hysteresis 2 3 -
IncombinationwithactuatorCES-A-BQAonevaluationunitCES-AZ
Operating distance for center offset m = 0 1)
mm
Cable length l = 0 to 25 m
- Assured switch-off distance Sar - - 60
For vertical approach direction
- Switch-on distance - 23 -
- Assured switch-on distance Sao 16 - -
- Switching hysteresis 2 3 -
For side approach direction
- Switch-on distance - 28 -
- Assured switch-on distance Sao 24 - -
- Switching hysteresis 1 1.3 -
Cable length - - 25 m
1) These values apply for surface installation of the read head and the actuator.
40
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
17
5
32 19,7
Read distance s
Cent
er o
ffset
m
connected 35
4
830
M12
x1
M8x
1
37
1)
1)
ReadheadCES-A-LMN-SC
Dimensiondrawing
ReadheadCES-A-LMN-SCM8 plug, 3-pin
Active face
CylindricaldesignM12M8plugconnector(snap-actionandscrewterminals)
Orderingtable
Series Connection Version Orderno./item
CES-A-LMN-SC SCM8 plug connector Housing M12 077790
CES-A-LMN-SC
CES-A-LMN-SC-EX SCM8 plug connector ATEX 1) 098157 1)
CES-A-LMN-SC-EX
1) EX II 3G Ex nL IIC T70°C (zone 2 gases)
TypicaloperatingdistanceTerminalassignment
H11 H12 SH1
BNWH
14
3
Screen
Read head
CES-AZ...
1) Clear zone (area of the active face without metal housing)For connection cable see page 69
For possible combinations see page 24
Attention:The operating distance may vary de-pending on the background material and installation situation.
Important:Actuators must be ordered sepa-rately! See page 48.
1)
A minimum distance of s = 1.2 mm must be maintained.
2
4
6
6
8
8
X8
64
22
46
8
86
Y
Z
41
Safety System CES-AZ
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
CES
-AZ
Parameter Value Unit
min. typ. max.
Housing material Nickel-plated CuZn housing sleevePlastic PBT GF20 cap
Dimensions M12 x 1, length 38 mm
Weight 0.2 kg
Ambient temperature
°C- CES-A-LMN-SC -20 - +70
- CES-A-LMN-SC-EX -20 - +60
Ambient pressure(only of active face in installed condition) - - 10 bar
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
IncombinationwithactuatorCES-A-BMB
Operating distance for center offset m = 0 1)
mm
- Assured switch-off distance Sar - - 10
Cable length l = 0 to 15 m
- Switch-on distance - 5 -
- Assured switch-on distance Sao 3.5 - -
- Switching hysteresis 0.1 0.3 -
Connection M8 plug connector (snap-action and screw terminals), 3-pin
Cable length - - 15 m1) These values apply for surface installation of the read head in steel.
TechnicaldatareadheadCES-A-LMN-SC