MDC Silicon meeting24 July 031

Run IIb SiliconTemperature Monitoring

The basic philosophy is to build on Run IIa experience and make only minor changes

Temperature monitoring will reproduce the existing system, with an additional system for L0/L1.

Page 2: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 032

Temperature Monitoring

Devices used are thin film platinum resistors, Resistance Temperature Detectors (RTDs)

The Run IIa system will be reproduced, with an RTD mounted on each hybrid. Integral part of the hybrid design Read out through standard online

monitoring 1553 system Temperature interlocks the power to each

hybrid

Page 3: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 033

L0/L1 Temperature Monitoring

A second temperature monitoring system will monitor the L0/L1 sensors

For L0, the hybrids are removed from the sensors L1 has the most difficult cooling problems, so a

redundant system is prudent

This system will also provide more accurate monitoring of other parts of the detector

Present system has an accuracy of about 2C, the new system will have an accuracy of 0.5C or better.

Will provide for better monitoring of the cooling system’s performance

Page 4: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 034

Honeywell HEL-700 RTDs

The RTDs have been selected and ordered, they are 1000 Ω, remarkably tiny devices. They are the two small specks to the left of the dime. Dimensions are 1.5mm x 0.75mm x 0.3mm.

Page 5: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 035

L0/L1 Temperature Readout

RTDs are read out through a commercial PLC system using commercial modules. This system is used for many monitoring and interlock functions throughout D0.

The crates and controllers (Texas Instruments 545) exist.

The readout module required modest re-engineering to handle 1000 Ω devices—already done and one module in hand.

Page 6: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 036

L0/L1 Temperature Readout

Readout module CTI-2557-SPQ391, 16 channel RTD module provides a constant DC current of 10 microamps and reads back the voltage.

Module, crate and controller are currently being tested at Rice. Tests underway: Channel-to-channel uniformity Linearity Stability over several months Accuracy of temperature measurement Compensation for lead resistance

Page 7: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 037

Readout module test set up at Rice

Page 8: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 038

Readout Module Test Setup at Rice

And the student who has done all the work.

Page 9: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 039

Readout Module Tests

First tests are being done using resistors, since the module in fact just measures resistance.

For a 1000Ω resistor, all channels tested so far measure within 1Ω of 1000Ω. This will provide for an accuracy of 0.3C.

All channels tested so far show excellent linearity from 10Ω to 1000 Ω and stability over time (up to 24hrs).

Page 10: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0310

Readout Module Tests

For a nominal 1000 Ω resistor, all the channels measured (8/16) are within 1Ω.

Linearity and stability are also excellent.

Ω

Ω

Page 11: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0311

Lead Resistance Compensation

But…the compensation for lead resistance seems to not work !

There are 4 leads, I1, I2 ,V+, and G. I1, I2

provide a constant current of 10μ A, while V+ and G measure the voltage drop.

Adding extra 10Ω to I1, I2 makes no difference, as expected This module is supposed to supply

constant current at least up to 1300 Ω. But adding 10 Ω to the G line makes a

huge difference!

Page 12: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0312

Lead resistance compensation tests

Use a 751Ω resistor with short leads, readout is 751Ω.

Adding 10Ω to I1, I2, V+, or any combination, readout is still 751Ω.

Add 10Ω to G changes the readback resistance to 833 Ω!

The G line is measured to carry 80μ amps!

Page 13: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0313

Lead compensation tests

The additional resistances (R’) added to G, the measured current in G, and the reported resistance are all consistent:

R(reported)= R(true) + 8*R’ R’= 5 Ω →R(reported)=792 R’=10Ω → R(reported)=833 R’=15Ω → R(reported)=874 R’=20Ω → R(reported)=915

Dan Markley contacted the vendors, they said “oops, we forgot to change some resistors”, the module has been sent back to them.

Page 14: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0314

Location of RTDs in L0/L1

Z-positions of RTDs in L0/L1 : L0 z=60mm and 480mm , six phi locations L1 z=64mm and 384mm, six phi locations

Z locations chosen to be at “hot spots” near electronics in Layer 1

Possible locations in outer layers not yet decided

Page 15: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0315

Flex cables for RTDs

The RTDs will be mounted on flex cables which will bring signals into and out of the detector. In the junction card region flex cables convert to a higher mass cable.

Length is an issue (36” at least is needed). A prototype is on order, but the vendor is very late in delivering.

Mike Matulik has some good ideas to make spliced flex cables which we are currently pursuing. These would be much less expensive and length would then not be an issue. (We may cancel the existing order and just pursue this last option).

Page 16: Run IIb SiliconTemperature Monitoring

MDC Silicon meeting24 July 0316

Conclusions

RTDs are in hand Readout module is being tested

Channel-to-channel uniformity and linearity are fine

Found a serious flaw in the lead resistance compensation which the vendor claims they can fix

Flex cables remain an issue…the vendor has not yet delivered prototypes. But we have another plan which should be better and cheaper