RoSphere : The germanium array at the Tandem accelerator of IFIN-HH

  • Upload
    melina

  • View
    93

  • Download
    3

Embed Size (px)

DESCRIPTION

RoSphere : The germanium array at the Tandem accelerator of IFIN-HH. Negret , D. Bucurescu , G. Cata-Danil , D. Deleanu , D. Filipescu , D.G. Ghita , I. Gheorghe, T. Glodariu , R. Lica , N. Marginean , R. Marginean , A. Olacel , S. Pascu , T. Sava, L. Stroe , G. Suliman , - PowerPoint PPT Presentation

Citation preview

PowerPoint Presentation

RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

Negret, D. Bucurescu, G. Cata-Danil, D. Deleanu, D. Filipescu, D.G. Ghita, I. Gheorghe, T. Glodariu, R. Lica, N. Marginean, R. Marginean, A. Olacel, S. Pascu, T. Sava, L. Stroe, G. Suliman, R. Suvaiala, S. Toma, and N.V. ZamfirHoria Hulubei National Institute for Physics and Nuclear Engineering, Bucharest-Magurele, ROMANIANSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013

Summary

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere Romanian Array for g Spectroscopy in Heavy Ion Reactions

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHA few words about The National Institute of Physics and Nuclear EngineeringIFIN-HH, Bucharest-Magurele, Romania - Location

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

IFIN-HH Main facilities and departments

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

CyclotronIradiation FacilityHadronic PhysicsSource ProductionReactor9 MV Tandem3 MV TandetronNUSTAR1 MV TandetronAdministrationLife & Environment

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHThe 9 MV Tandem acceleratorThe 9 MV Tandem accelerator

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

Built by High Voltage Engineering Corporation (HVEC) in 1973, upgraded from the original terminal voltage of 7.5 MV (FN machine) to 9 MV.Major upgrades during the last years.The 9 MV Tandem

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHIon sources: Available beams: p (2 18 MeV), a (3 27 MeV) a broad range of heavy ions Pulsing systems: SNICSII sputter negative ion source source for negative helium ions MC-SNICSII sputter negative ion source dedicated for AMSHV generator: pelletron system; Voltage: 9 MV milliseconds: chopper nanoseconds: chopper + buncherExperimental area

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH2 experimental halls

7 beam lines

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHRoSphere: The Romanian Array for g Spectroscopy in Heavy Ion ReactionsRoSphere

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

Two configurations available:Mixed array with 15 50% HPGe detectors with BGO shields and 10-20 LaBr3(Ce) scintillators25 HPGe detectors arrayRoSphere with LaBr3(Ce)

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

14 HPGe detectors11 LaBr3(Ce) detectorsJuly 2012

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHRecent measurements at RoSphereThe first experiment with RoSphere:RDDS lifetime measurements in 120Te

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

110Pd(13C,3n) 120Te @50 MeV0.7 mg/cm2 110Pd Plunger device12 HPGe detectors mounted:5 @ 37 + 5 @ 1431 @ 63 + 1 @ 117

C. Mihai et al.The first experiment with RoSphere:RDDS lifetime measurements in 120Te

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

Target supportStopper supportmicrometerSliding bearingsinchwormpiezocrystalL=814 mmPlunger device build after the widely used Cologne design (A. Dewald)C. Mihai et al.The first experiment with RoSphere:RDDS lifetime measurements in 120Te

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

2+ 560 keV =12.2(4) ps

4+ 1161 keV =4.8(4) ps

VERY PRELIMINARY RESULTSC. Mihai et al.In-beam Fast Timing measurements: 199Tl

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

197Au(,2n)199Tl @ 24 MeV

N.Mrginean et al., Eur. Phys. J. A46, 329 (2010)

332-369 keV coincidencePrompt coincidence367-381 keV coincidenceCentroid shiftIn-beam Fast Timing measurements in 99,101,103Ru

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH 96Mo(,n) 99Ru 98Mo(,n)101Ru100Mo(,n)103RuS. Lalkovski et al.96,98Ru have vibrational behaviour, while the mid-shell Ruisotopes are triaxialy deformed. Thus, 99,101,103Ru isotopes are placed in the region where the onset of deformation is expected to occur.

Ea = 14-18 MeVExperimental purpose: measurement of the half lives of positive parity low-lying states and 15/2- states in 99,101,103Ru In-beam Fast Timing measurements in 99,101,103Ru

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHS. Lalkovski et al.

In-beam Fast Timing measurements in 99,101,103Ru

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHS. Lalkovski et al.

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHOther fields of research in the Nuclear Physics DepartmentNuclear physics measurements for energetics: The development of Generation IV Nuclear Reactors

Precise Neutron Inelastic Cross Section Measurements @ GELINA, EC-JRC-IRMM, BelgiumA. Negret, C. Borcea, Ph. Dessagne, M. Kerveno, A.J.M. Plompen

Required uncertainty level: ~5%NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHSpectroscopy of the A=34 decay chain at ISOLDE, CERN

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

Spokespersons: F. Negoita, S. Grvy

Structure based on OSIRIS (Bucharest)3 CLOVER detectors (Bucharest)1 HPGe detector (90%) (CEA Arpajon)5 LaBr3 detectors (4 Legnaro, 1 Bucharest)~4p plastic scintilator (Bucharest)3 neutron detectors (DEMON)Fast Tape Station (Strasbourg)NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHLarge European Projects

NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A few words about IFIN-HH, Bucharest, ROMANIA

The 9 MV Tandem accelerator

RoSphere

Recent measurements at RoSphere

Other fields of research in the Nuclear Physics Department

ConclusionsA. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HHConclusionsNSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

AdvertisementThe ERINDA consortium groups 13 partners, equipped with nuclear data research infrastructures. The project sponsors the transnational access for experiments performed at any of the 13 facilities.The TANDEM accelerator of IFIN-HH is part of ERINDA.The last deadline for proposals: September 30, 2012www.erinda.org

Future project proposed for transnational access: CHANDA. NSDD Meeting, KFAS, Safat, Kuwait, January 27-31, 2013A. Negret et al. - RoSphere: The germanium array at the Tandem accelerator of IFIN-HH

ConclusionsThe 9 MV Tandem accelerator in Bucharest delivers a large variety of stable beams. The facility was completely modernized during the last years.

A large variety of detecting devices are available:The RoSphere array with up to 25 HPGe detectors and/or LaBr3 detectors,Clover detectors,A plunger device,Neutron detectors.

We are particularly well equipped for nuclear lifetime measurements.

Financial support is available for certain type of measurements.

Two PAC meetings /year; usually the requested beam time represents 150%-200% of the available beam time.