MISSOURI LOTTERY HEADQUARTERS
OWNER: STATE OF MISSOURIMICHAEL L. PARSON, GOVERNOR
PROJECTMANAGEMENT:
OFFICE OF ADMINISTRATIONDIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
PROJECT NUMBER: N200701
ASSET NUMBER:LOTTERY HEADQUARTERS BUILDING: 8611951001
JEFFERSON CITY, MISSOURI
ROOF REPLACEMENTS
SHEET NUMBER:
G-101 1 OF 5 SHEETSFEBRUARY 27, 2020
DEPARTMENT OF REVENUE,STATE LOTTERY COMMISSION
AND DISTRIBUTION CENTER
DISTRIBUTION CENTER: 8611951002
HEADQUARTERS
DISTRIBUTION
CENTER
SHEET NO. SHEET NAME DESCRIPTION
1 G-101 COVER SHEET
2
3
4
5
A-102
A-103 ROOF PLAN - DISTRIBUTION CENTER
A-501 ROOF DETAILS
A-101 ROOF PLAN - HEADQUARTERS
ROOF PLAN - HEADQUARTERS
E
E
E
E
151'-4"
22'-4"
151'-4"
V
43'-8"10'-8"21'-8"10'-8"64'-8"
69'-10"
21'-8"
69'-10"
161'-4"
11.5"
1.5"
11.5"
11.5"
6.5"
1.5" 1.5" 1.5"
6.5"
1.5" 1.5" 1.5"
5.5"5.5"
6.5"
3.5"
.5:12 .5:12
.2
5:1
2
.5:12
.2
5:1
2
.5:12
.5:12
.2
5:1
2
.5:12
.5:12
.5
:1
2
.5:12
.2
5:1
2
.2
5:1
2
.2
5:1
2
.25:12
.5:12
.5:12
.2
5:1
2
.5:12
.2
5:1
2
.5:12
.2
5:1
2
.5:12
.2
5:1
2
.5:12
.2
5:1
2
.2
5:1
2
.2
5:1
2
.2
5:1
2
9.5"
RTU - 4 RTU - 3
RTU - 2
RTU - 1
RTU - 5
RIDGE
2
10
65
7
8
13 13 13
6
5
4
11
10
10
2
1
9
1715
6 6
10 10
10
11
13 13 13 13
23
10
1715
15
14
14
6
15
6
6
3
17
65
24
6
15
6
56
22
2
3
3
A-501
16
15
16
16
6
12.5"
6
17
17
6
7
65
65
3
A-501
1
A-501
2
A-501
25 25
25
25
25
25
25
25
25
.25:12 FINISH SLOPE
BUILDING HAS .125:12 MECH SLOPE
.25:12 FINISH SLOPE
BUILDING HAS .125:12 MECH SLOPE
.5:12
.5:12
3/32" = 1'-0"
ROOF PLAN
1
####-#####-2020-0227-####
ISSUE DATE:
SHEET NUMBER:
CHECKED BY:DRAWN BY:
DESIGNED BY:
DATE:REVISION:
SHEET TITLE:
REVISION:DATE:
REVISION:DATE:
CAD DWG FILE:
STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR
OFFICE OFADMINISTRATIONDIVISION OF FACILITIESMANAGEMENT / DESIGNAND CONSTRUCTION
A-101
DEPARTMENT OF REVENUESTATE LOTTERY COMMISSION
ROOF REPLACEMENTS
MISSOURI LOTTERYHEADQUARTERS ANDDISTRIBUTION CENTER
1823 SOUTHRIDGE DRIVEJEFFERSON CITY, MISSOURI
PROJECT # N200701ASSET #LOTTERY HEADQUARTERS8611951001DISTRIBUTION CENTER8611951002
2/27/2020
N200701A-RF-A101Rkelled
blockl
ROOF PLAN - HEADQUARTERS
MA
TC
H LIN
E
SE
E D
RA
WIN
G A
-102
NOT TO SCALE
KEY PLAN
NORTH
SHEET 2 OF 5
KEYED NOTES1 REMOVE EXISTING FULLY ADHERED TPO ROOF SYSTEM DOWN TO THE
EXISTING METAL DECK. INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM PER DETAILS AND SPECIFICATIONS.
2 REMOVE EXISTNG FULLY ADHERED EPDM ROOF SYSTEM DOWN TO THE EXISTING METAL DECK. INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM PER DETAILS AND SPECIFICATIONS.
3 MOVEMENT AND REINSTALLATION OF EXISTING CONDENSING UNIT (SERVING TEMPERATURE SENSITIVE EQUIPMENT) SHALL BE COORDINATEDWITH OWNER. RE-USE EXISTING SUPPORT PADS FOR THIS UNIT.
4 EXISTING SATELLITE DISH TO REMAIN. COORDINATE RELOCATION DURINGCONSTRUCTION WITH OWNER.
5 EXISTING CONDENSING UNIT, INCLUDING EQUIPMENT PADS, TO REMAIN.6 REPLACE EXISTING ROOF PENETRATION CURB WITH NEW URETHANE CURB
SYSTEM.7 EXISTING SATELLITE TO REMAIN. OPERATION TO BE MAINTAINED
THROUGHOUT CONSTRUCTION.8 EXISTING METAL FLASHING OVER SATELLITE FRAME/PARAPET WALL
CONNECTION TO BE REMOVED. INSTALL NEW PREFINISHED METAL FLASHING TO MATCH EXISTING.
9 EXISTING METAL PARAPET CAP TO BE REMOVED. COMPLETELY COVER PARAPET WITH FULLY ADHERED MEMBRANE WITH NO METAL CAP.
10 EXISTING METAL PARAPET CAP TO BE REMOVED. INSTALL NEW PRE-FINISHED METAL FASCIA COVER (DRIP EDGE) OVER NEW MEMBRANE PER DETAIL 3/A-501.
11 EXISTING VIDEO SECURITY SYSTEM TO REMAIN DURING CONSTRUCTION. COORDINATE TEMPORARY REMOVAL AND REINSTALLATION WITH OWNERPRIOR TO CONSTRUCTION.
12 EXISTING SATELLITE TO REMAIN IN OPERATION DURING CONSTRUCTION.13 EXISTING ROOF SCUPPER AND CONDUCTOR HEAD/DOWNSPSOUT TO
REMAIN. PROVIDE NEW FLASHING PER MANUFACTURER.14 EXISTING ROOF TRANSITION “STEP”: INSPECT SUBSTRATE FOR DAMAGE
AND REPAIR AS NECESSARY. INSTALL NEW MEMBRANE ROOFING SYSTEM.15 EXISTING ROOFTOP UNIT: FLASH PER MANUFACTURER'S
RECOMMENDATION.16 EXISTING ROOF VENT: FLASH PER MANUFACTURER'S RECOMMENDATION.17 INSTALL 30” WIDE WALKWAY PADS WHERE SHOWN ON ROOF PLAN.18 EXISTING ROOF HATCH SHALL REMAIN. INSTALL NEW PERIMETER SAFETY
RAILING SYSTEM AROUND ROOF HATCH. SEE DETAIL 5/A-501.19 COORDINATE TEMPORARY REMOVAL AND REINSTALLATION OF FLEXIBLE
CONDUIT FOR WALL MOUNTED SECURITY CAMERA, IF REQUIRED20 REMOVE AND DISPOSE OF EXISTING CONDENSING UNIT. SALVAGE
EXISTING EQUIPMENT PAD AND RELOCATE TO EXISTING CONDENSING UNITAS NOTED.
21 INSTALL RELOCATED EQUIPMENT PAD FOR EXISTING CONDENSING UNIT.22 REMOVE EXISTING I-BEAMS AND REINSTALL EXISTING SATELLITES ON
EXISTING EQUIPMENT PADS.23 RELOCATE EXISTING JUNCTION BOX BELOW ROOF.24 REMOVE EXISTING CURB.25 INSTALL ½” PER 1' INSULATION CRICKET.
GENERAL NOTES26 DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS.27 CONTRACTOR SHALL FLASH AROUND ALL ROOF PENETRATIONS AND CURBS
PER MANUFACTURERS RECOMMENDATIONS, WHETHER SPECIFICALLY SHOWN OR NOT.
28 THE ENTIRE ROOF SYSTEM SHALL BE FULLY ADHERED. NO FASTENERS MAYPENETRATE THE EXISTING METAL DECKING DUE TO ELECTRICAL EQUIPMENT/CONDUIT LOCATED AGAINST THE UNDERSIDE OF THE DECK.
RTU
RTU
RTU
RTU
RTU
RTU
RTU
RTU
RTU
RTU
RTU
RTU
RTU
E
E
E
E
E
E
V
267'-4"
56'-0"
26'-0 1/4"
22'-4" 20'-0" 171'-4" 15'-8"
38'-0"
267'-4"
161'-4 1/2"
V
V
V
V
V
V
11.5"
11.5"
.5:12
.5:12
V
V
1
9
5
6
22
79'-4 1/4"
1
10
15
15
15
13 13 13
13 13 13 13TYP.
2
2.5"
3
A-501
3
A-501
3
A-501
3
A-501
3
A-501
1
A-501
4
A-501
Typ
16
16
15
15
16
16 16
6
20
10
15
16
16
VENT
TYP.
E
SLOPE19
15
15
17 TYP.
17 TYP.
15
.25:12 FINISH SLOPE
BUILDING HAS .125:12 MECH SLOPE
.25:12 FINISH SLOPE
BUILDING HAS .125:12 MECH SLOPE
10
18
6
3
12.5"
EXISTING
HYDRANT
12.5"
15
16
10
10
2.5"
621
RTU
65
2
A-501
25
25
25
.5:12 .5:12.5:12 .5:12.5:12 .5:12
25 25
25
25
25
25
25
2525
25
.5:12 .5:12 .5:12 .5:12.5:12 .5:12.5:12 .5:12
25
2525 2525
3/32" = 1'-0"
ROOF PLAN
1
####-#####-2020-0227-####
ISSUE DATE:
SHEET NUMBER:
CHECKED BY:DRAWN BY:
DESIGNED BY:
DATE:REVISION:
SHEET TITLE:
REVISION:DATE:
REVISION:DATE:
CAD DWG FILE:
STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR
OFFICE OFADMINISTRATIONDIVISION OF FACILITIESMANAGEMENT / DESIGNAND CONSTRUCTION
A-102
DEPARTMENT OF REVENUESTATE LOTTERY COMMISSION
ROOF REPLACEMENTS
MISSOURI LOTTERYHEADQUARTERS ANDDISTRIBUTION CENTER
1823 SOUTHRIDGE DRIVEJEFFERSON CITY, MISSOURI
PROJECT # N200701ASSET #LOTTERY HEADQUARTERS8611951001DISTRIBUTION CENTER8611951002
2/27/2020
N200701A-RF-A101Rkelled
blockl
ROOF PLAN - HEADQUARTERS
MA
TC
H LIN
E
SE
E D
RA
WIN
G A
-101
NOT TO SCALE
KEY PLAN
NORTH
SHEET 3 OF 5
KEYED NOTES1 REMOVE EXISTING FULLY ADHERED TPO ROOF SYSTEM DOWN TO THE
EXISTING METAL DECK. INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM PER DETAILS AND SPECIFICATIONS.
2 REMOVE EXISTNG FULLY ADHERED EPDM ROOF SYSTEM DOWN TO THE EXISTING METAL DECK. INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM PER DETAILS AND SPECIFICATIONS.
3 MOVEMENT AND REINSTALLATION OF EXISTING CONDENSING UNIT (SERVING TEMPERATURE SENSITIVE EQUIPMENT) SHALL BE COORDINATEDWITH OWNER. RE-USE EXISTING SUPPORT PADS FOR THIS UNIT.
4 EXISTING SATELLITE DISH TO REMAIN. COORDINATE RELOCATION DURINGCONSTRUCTION WITH OWNER.
5 EXISTING CONDENSING UNIT, INCLUDING EQUIPMENT PADS, TO REMAIN.6 REPLACE EXISTING ROOF PENETRATION CURB WITH NEW URETHANE CURB
SYSTEM.7 EXISTING SATELLITE TO REMAIN. OPERATION TO BE MAINTAINED
THROUGHOUT CONSTRUCTION.8 EXISTING METAL FLASHING OVER SATELLITE FRAME/PARAPET WALL
CONNECTION TO BE REMOVED. INSTALL NEW PREFINISHED METAL FLASHING TO MATCH EXISTING.
9 EXISTING METAL PARAPET CAP TO BE REMOVED. COMPLETELY COVER PARAPET WITH FULLY ADHERED MEMBRANE WITH NO METAL CAP.
10 EXISTING METAL PARAPET CAP TO BE REMOVED. INSTALL NEW PRE-FINISHED METAL FASCIA COVER (DRIP EDGE) OVER NEW MEMBRANE PER DETAIL 3/A-501.
11 EXISTING VIDEO SECURITY SYSTEM TO REMAIN DURING CONSTRUCTION. COORDINATE TEMPORARY REMOVAL AND REINSTALLATION WITH OWNERPRIOR TO CONSTRUCTION.
12 EXISTING SATELLITE TO REMAIN IN OPERATION DURING CONSTRUCTION.13 EXISTING ROOF SCUPPER AND CONDUCTOR HEAD/DOWNSPSOUT TO
REMAIN. PROVIDE NEW FLASHING PER MANUFACTURER.14 EXISTING ROOF TRANSITION “STEP”: INSPECT SUBSTRATE FOR DAMAGE
AND REPAIR AS NECESSARY. INSTALL NEW MEMBRANE ROOFING SYSTEM.15 EXISTING ROOFTOP UNIT: FLASH PER MANUFACTURER'S
RECOMMENDATION.16 EXISTING ROOF VENT: FLASH PER MANUFACTURER'S RECOMMENDATION.17 INSTALL 30” WIDE WALKWAY PADS WHERE SHOWN ON ROOF PLAN.18 EXISTING ROOF HATCH SHALL REMAIN. INSTALL NEW PERIMETER SAFETY
RAILING SYSTEM AROUND ROOF HATCH. SEE DETAIL 5/A-501.19 COORDINATE TEMPORARY REMOVAL AND REINSTALLATION OF FLEXIBLE
CONDUIT FOR WALL MOUNTED SECURITY CAMERA, IF REQUIRED20 REMOVE AND DISPOSE OF EXISTING CONDENSING UNIT. SALVAGE
EXISTING EQUIPMENT PAD AND RELOCATE TO EXISTING CONDENSING UNITAS NOTED.
21 INSTALL RELOCATED EQUIPMENT PAD FOR EXISTING CONDENSING UNIT.22 REMOVE EXISTING I-BEAMS AND REINSTALL EXISTING SATELLITES ON
EXISTING EQUIPMENT PADS.23 RELOCATE EXISTING JUNCTION BOX BELOW ROOF.24 REMOVE EXISTING CURB.25 INSTALL ½” PER 1' INSULATION CRICKET.
GENERAL NOTES26 DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS.27 CONTRACTOR SHALL FLASH AROUND ALL ROOF PENETRATIONS AND CURBS
PER MANUFACTURERS RECOMMENDATIONS, WHETHER SPECIFICALLY SHOWN OR NOT.
28 THE ENTIRE ROOF SYSTEM SHALL BE FULLY ADHERED. NO FASTENERS MAYPENETRATE THE EXISTING METAL DECKING DUE TO ELECTRICAL EQUIPMENT/CONDUIT LOCATED AGAINST THE UNDERSIDE OF THE DECK.
152'-0"
50'-2 3/4"
75'-6"
84'-8" 35'-4" 32'-0"
8'-0"
117'-8 3/4"
3
A-501
Sim
3
A-501
Sim
3
A-501
3
A-501
Sim
RTU
RTURTU
RTU
RTU
3
A-501
Sim
125'-8 3/4"
DUSK TO DAWN
SENSOR
ACCESS LADDER
V
V
EX
IS
T. 1/4" : 12"
DS DS DS DS
4
A-501
Sim
A-103
2
A-103
3
10
10
10
10EXISTING
13 13 13 13
10 17
161
156
156
156
156
156
.5:12 .5:12 .5:12 .5:12 .5:12 .5:12
.5:12.5:12
25 2525 25
25
25 25
25
25NEW FULLY ADHERED TPO
OVER ADHERED COVER BOARD
OVER ADHERED 5" RIGID INSULATION
OVER EXISTING METAL DECK.
5" M
IN
. R
IG
ID
IN
SU
LA
TIO
N
50'-0"
7'-5 11/16"
EXISTING ROOF DRAIN
3
A-501
Sim
3
A-501
Sim
.125":12"
.
.1
25
":1
2"
2
A-501
Sim
NO EXISTING SLOPE, TYP.
1
10
FULLY ADHERED TPO MEMBRANE
OVER 1/2" COVER BOARD
OVER .125":12" TAPERED RIGID
INSULATION OVER EXISTING
METAL DECK.
ROOF DRAIN
31'-6"
3
A-501
Sim
3
A-501
Sim
.125" : 12"
2
A-501
Sim
EXISTING
1
10
1/8" = 1'-0"
ENTRY CANOPY - DISTRIBUTION CENTER
2
####-#####-2020-0227-####
ISSUE DATE:
SHEET NUMBER:
CHECKED BY:DRAWN BY:
DESIGNED BY:
DATE:REVISION:
SHEET TITLE:
REVISION:DATE:
REVISION:DATE:
CAD DWG FILE:
STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR
OFFICE OFADMINISTRATIONDIVISION OF FACILITIESMANAGEMENT / DESIGNAND CONSTRUCTION
A-103
DEPARTMENT OF REVENUESTATE LOTTERY COMMISSION
ROOF REPLACEMENTS
MISSOURI LOTTERYHEADQUARTERS ANDDISTRIBUTION CENTER
1823 SOUTHRIDGE DRIVEJEFFERSON CITY, MISSOURI
PROJECT # N200701ASSET #LOTTERY HEADQUARTERS8611951001DISTRIBUTION CENTER8611951002
2/27/2020
N200701A-RF-A101Rkelled
blockl
ROOF PLAN - DISTRIBUTION CENTER
NOT TO SCALE
KEY PLAN
3/32" = 1'-0"
ROOF PLAN - DISTRIBUTION CENTER
1
1/8" = 1'-0"
DOCK CANOPY - DISTRIBUTION CENTER
3
NORTH
SHEET 4 OF 5
KEYED NOTES1 REMOVE EXISTING FULLY ADHERED TPO ROOF SYSTEM DOWN TO THE
EXISTING METAL DECK. INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM PER DETAILS AND SPECIFICATIONS.
2 REMOVE EXISTNG FULLY ADHERED EPDM ROOF SYSTEM DOWN TO THE EXISTING METAL DECK. INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM PER DETAILS AND SPECIFICATIONS.
3 MOVEMENT AND REINSTALLATION OF EXISTING CONDENSING UNIT (SERVING TEMPERATURE SENSITIVE EQUIPMENT) SHALL BE COORDINATEDWITH OWNER. RE-USE EXISTING SUPPORT PADS FOR THIS UNIT.
4 EXISTING SATELLITE DISH TO REMAIN. COORDINATE RELOCATION DURINGCONSTRUCTION WITH OWNER.
5 EXISTING CONDENSING UNIT, INCLUDING EQUIPMENT PADS, TO REMAIN.6 REPLACE EXISTING ROOF PENETRATION CURB WITH NEW URETHANE CURB
SYSTEM.7 EXISTING SATELLITE TO REMAIN. OPERATION TO BE MAINTAINED
THROUGHOUT CONSTRUCTION.8 EXISTING METAL FLASHING OVER SATELLITE FRAME/PARAPET WALL
CONNECTION TO BE REMOVED. INSTALL NEW PREFINISHED METAL FLASHING TO MATCH EXISTING.
9 EXISTING METAL PARAPET CAP TO BE REMOVED. COMPLETELY COVER PARAPET WITH FULLY ADHERED MEMBRANE WITH NO METAL CAP.
10 EXISTING METAL PARAPET CAP TO BE REMOVED. INSTALL NEW PRE-FINISHED METAL FASCIA COVER (DRIP EDGE) OVER NEW MEMBRANE PER DETAIL 3/A-501.
11 EXISTING VIDEO SECURITY SYSTEM TO REMAIN DURING CONSTRUCTION. COORDINATE TEMPORARY REMOVAL AND REINSTALLATION WITH OWNERPRIOR TO CONSTRUCTION.
12 EXISTING SATELLITE TO REMAIN IN OPERATION DURING CONSTRUCTION.13 EXISTING ROOF SCUPPER AND CONDUCTOR HEAD/DOWNSPSOUT TO
REMAIN. PROVIDE NEW FLASHING PER MANUFACTURER.14 EXISTING ROOF TRANSITION “STEP”: INSPECT SUBSTRATE FOR DAMAGE
AND REPAIR AS NECESSARY. INSTALL NEW MEMBRANE ROOFING SYSTEM.15 EXISTING ROOFTOP UNIT: FLASH PER MANUFACTURER'S
RECOMMENDATION.16 EXISTING ROOF VENT: FLASH PER MANUFACTURER'S RECOMMENDATION.17 INSTALL 30” WIDE WALKWAY PADS WHERE SHOWN ON ROOF PLAN.18 EXISTING ROOF HATCH SHALL REMAIN. INSTALL NEW PERIMETER SAFETY
RAILING SYSTEM AROUND ROOF HATCH. SEE DETAIL 5/A-501.19 COORDINATE TEMPORARY REMOVAL AND REINSTALLATION OF FLEXIBLE
CONDUIT FOR WALL MOUNTED SECURITY CAMERA, IF REQUIRED20 REMOVE AND DISPOSE OF EXISTING CONDENSING UNIT. SALVAGE
EXISTING EQUIPMENT PAD AND RELOCATE TO EXISTING CONDENSING UNITAS NOTED.
21 INSTALL RELOCATED EQUIPMENT PAD FOR EXISTING CONDENSING UNIT.22 REMOVE EXISTING I-BEAMS AND REINSTALL EXISTING SATELLITES ON
EXISTING EQUIPMENT PADS.23 RELOCATE EXISTING JUNCTION BOX BELOW ROOF.24 REMOVE EXISTING CURB.25 INSTALL ½” PER 1' INSULATION CRICKET.
GENERAL NOTES26 DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS.27 CONTRACTOR SHALL FLASH AROUND ALL ROOF PENETRATIONS AND CURBS
PER MANUFACTURERS RECOMMENDATIONS, WHETHER SPECIFICALLY SHOWN OR NOT.
28 THE ENTIRE ROOF SYSTEM SHALL BE FULLY ADHERED. NO FASTENERS MAYPENETRATE THE EXISTING METAL DECKING DUE TO ELECTRICAL EQUIPMENT/CONDUIT LOCATED AGAINST THE UNDERSIDE OF THE DECK.
ROOF EDGE WITH UNA-EDGE GRAVEL STOP (GS)
1/2" (13 mm) MIN.
1/2" (13 mm) MIN.
EXISTINGMASONRY WALL
1-3/4" STAINLESS STEEL RING SHANK 5DCOMMON NAILS @ 8" (203 mm) O.C. MAX. 3/4"FROM TOP OF CLEAT.
CONTINUOUS BEAD OFTPO GP SEALANT (REQUIRED)
1-1/4" HOT DIPPED GALVANIZED ROOFNAILS @ 6" (152 mm) O.C. MAX
EXISTNG WOOD NAILER
PRE-FINISHED METALSYSTEM 8" MAX FACE
20 GA.CONTINUOUS CLEAT
INSTALL PERIMETER SAFETY
RAILING SYSTEM, PER ROOF
HATCH MANUFACTURER.
TYPICAL.
ACCESS GATE
1 1/2" = 1'-0"
CANOPY WALL DETAIL
2
####-#####-2020-0227-####
ISSUE DATE:
SHEET NUMBER:
CHECKED BY:DRAWN BY:
DESIGNED BY:
DATE:REVISION:
SHEET TITLE:
REVISION:DATE:
REVISION:DATE:
CAD DWG FILE:
STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR
OFFICE OFADMINISTRATIONDIVISION OF FACILITIESMANAGEMENT / DESIGNAND CONSTRUCTION
A-501
DEPARTMENT OF REVENUESTATE LOTTERY COMMISSION
ROOF REPLACEMENTS
MISSOURI LOTTERYHEADQUARTERS ANDDISTRIBUTION CENTER
1823 SOUTHRIDGE DRIVEJEFFERSON CITY, MISSOURI
PROJECT # N200701ASSET #LOTTERY HEADQUARTERS8611951001DISTRIBUTION CENTER8611951002
2/27/2020
N200701A-RF-A501Rkelled
blockl
ROOF DETAILS
1 1/2" = 1'-0"
WALL TRANISITION DETAIL
1
TPO MEMBRANE
PLATED MEMBRANE FASTENERS @ 6" O.C. MAX TPO FLASHING
TPO MEMBRANE COVER BOARD TAPERED INSULATION SYSTEM
EXISTING E.I.F.S.PARAPET WALL
PREFINISHED METALFASCIA COVER
EXISTING WOOD BLOCKINGEXTEND MEMBRANE OVER WALL
TPO MEMBRANE COVER BOARDTAPERED INSULATION SYSTEM
MEMBRANE FLASHING
EXISTING WOOD BLOCKING
TPO MEMBRANE
PLATED MEMBRANE FASTENERS @ 6" O.C. MAX TPO FLASHING TPO MEMBRANE COVER BOARD TAPERED INSULATION SYSTEM
EXISTING METAL DECK
1 1/2" = 1'-0"
RTU CURB SECTION
4
PRE-FINISHED COUNTER FLASHING WITHFOLDED LOWER EDGE FASTENED @ 8" O.C. MAX
EXISTING RTU GASKETEXISTING RTU CURB FRAMENEOPRENE-GASKETED METAL TO WOODFASTENERS
FULLY ADHERED MEMBRANEEXISTING CANT
FULLY ADHERED MEMBRANE COVER BOARD
TAPERED INSULATION SYSTEM
6" = 1'-0"
TERMINATION AT TOP OF WALL WITH FASCIA COVER
3
EXISTING WOOD BLOCKING
EXISTING INSULATION SYSTEM
NOT TO SCALE
ROOF HATCH SAFETY RAILING
5
SHEET 5 OF 5