Rodent Housing www.AllentownInc.com 609-259-7951 © Allentown, Inc. All Rights Reserved PNC Rack Rat: PNC System Single Face with Rear Plenums Specifications: Installation Options: (opposite side plenums shown for clarity) *FLOW DETECTORS USED ONLY DURING RACK INSTALLATION Features: HEPA filtered supply and exhaust air Operates in positive or negative pressure at the press of a button Microprocessor controlled Blowers Split platform for maximum visibility Capacity of 15 or 20 cages 2000 cm 2 / 310 in 2 per cage Optional Bluetooth remote monitoring Thimble exhaust connection Same side plenums Automatic H2O Rack Size* Cage Size Supply Airflow Exhaust Airflow Positive Negative ACH 15 T2000 24 CFM (40.8 m 3 /hr) 18 CFM @ 0.060 in H2O (30.6 m 3 /hr @ 14.9 Pa) 30 CFM @ 0.165 in H2O (50.9 m 3 /hr @ 41.1 Pa) 60 20 T2000 31 CFM (52.7 m 3 /hr) 23 CFM @ 0.050 in H2O (39.1 m 3 /hr @ 12.5 Pa) 39 CFM @ 0.175 in H2O (66.3 m 3 /hr @ 43.6 Pa) 60 Supply Blower / Direct Exhaust Direct Supply & Exhaust Supply & Exhaust Blowers (Thimble Connect) Supply & Exhaust Blowers Note: a.) Airflow at sea-level b.) Rack weight without blowers, animals, bedding or watering; c.) Airflow tolerance ±10% d.) *Other configurations available

Rodent Housing PNC Rack

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Rodent Housing PNC Rack

Rodent Housing

www.AllentownInc.com 609-259-7951 © Allentown, Inc. All Rights Reserved

PNC Rack

Rat: PNC System Single Face with Rear Plenums

Specifications:

Installation Options: (opposite side plenums shown for clarity)

*FLOW DETECTORS USED ONLY DURING RACK INSTALLATION

Features: • HEPA filtered supply and exhaust air • Operates in positive or negative pressure at the press

of a button • Microprocessor controlled Blowers • Split platform for maximum visibility • Capacity of 15 or 20 cages • 2000 cm2 / 310 in2 per cage Optional • Bluetooth remote monitoring • Thimble exhaust connection • Same side plenums • Automatic H2O

Rack Size*

Cage Size Supply Airflow

Exhaust Airflow Positive Negative ACH

15 T2000 24 CFM (40.8 m3/hr) 18 CFM @ 0.060 in H2O (30.6 m3/hr @ 14.9 Pa)

30 CFM @ 0.165 in H2O (50.9 m3/hr @ 41.1 Pa)

60

20 T2000 31 CFM (52.7 m3/hr) 23 CFM @ 0.050 in H2O (39.1 m3/hr @ 12.5 Pa)

39 CFM @ 0.175 in H2O (66.3 m3/hr @ 43.6 Pa)

60

Supply Blower / Direct Exhaust

Direct Supply & Exhaust

Supply & Exhaust Blowers (Thimble Connect)

Supply & Exhaust Blowers

Note: a.) Airflow at sea-level b.) Rack weight without blowers, animals, bedding or watering; c.) Airflow tolerance ±10% d.) *Other configurations available

Page 2: Rodent Housing PNC Rack

REV 01/2015

   Allentown  products  are  highly  customizable  at  the  end  users  request  and  this  data  sheet  may  not  reflect  the  exact  parameters  specified  for  a  specific  project.    Allentown  recommends  that  projects  that  have  critical  size,  airflow,  water  or  electrical  needs  be  handled  through  approval  drawings  to  insure  all  critical  areas  are  addressed  and  have  visibility  throughout  the  team  including,  A&E,  MEP  and  construction  persons.  

PNC Racks

*FLOW DETECTORS USED ONLY DURING RACK INSTALLATION

Physical Dimensions:

8.274”210mm

11.946”303mm

23.493”597mm

639mm25.150”

24.329”618mm

16.243”413mm

16.614”422mm

Standard design (shown)

Watering SHR

Platform Suspended

Caster 5” (127mm) Diameter

Supply Blower EFS

Exhaust Blower EFE

Rack Dimensions Rack Size 15 20

inches mm inches mm

A 58.88 1495 77.25 1962 B 75.13 1908 77.25 1962 C 33.50 851 34.50 876 D SupplyPAK = 9.25in / 235mm

D ExhaustPAK = 9.25in / 235mm

E 26.38 670 18.38 467 F 15.00 381 29.19 741 G 3.50 89 4.00 102 H 19.13 486 19.13 486 I 14.6 371 14.6 371