10
ROBUSTA PM www.fermator.com Automatic horizontal sliding car door DOC-FECMCBPRUC00EN PRINTABLE VERSION: 27-04-2015 ENG Commercial Residential Service lifts

ROBUSTA PM - Ascenseurs-Online · ROBUSTA PM Automatic horizontal sliding car door DOC-FECMCBPRUC00EN PRINTABLE VERSION: 27-04-2015 …

  • Upload
    dokhanh

  • View
    218

  • Download
    3

Embed Size (px)

Citation preview

ROBUSTA PM

www.fermator.com

Automatic horizontal sliding car door

DOC-FECMCBPRUC00ENPRINTABLE VERSION: 27-04-2015ENG

CommercialResidential Service lifts

www.fermator.com 2Robusta PM

APPLICATION RANGE

Opening Clear opening - PL Clear height - HL

Inches mm Inches mmC2 30 - 59 750 - 1.500

70 7/8 - 157 1/2 1.800 - 4.000T1 24 - 45 600 - 1.150T2 30 - 72 750 - 1.829

Door configuration

PROTECTION

Opening

IP21Protection against a solid foreign body of 12,5 mm or more in diameter and

protected against vertically falling drops of water.

IPX3Protected against sprays of water up to 60 degrees from

the vertical.

IP54Protection against dust and

protected against water splashed from all directions.

IP65Sealed against dust and

protected against jets of water from all directions.

EExExplosion proof, Group II (surface

industries) and Category 2 (explosive atmosphere between

10 and 1.000 hrs/yr).

C2 T1 - T2

SILLS

Type of sill Aluminium Reinforced aluminium Steel* Massive* Steel hidden* Brass

Profile detail - - -

Availability

Heated sill option

Dust holes Sill support

*Stainless steel / Galvanized.

PANELS

Opening

Steel panels Glass panels

Metal sheet

Double skin Vision Gridded

vision

Wien type

visionBevel big

visionFlush big

vision Full glassFull glass

built in moorings

Full glass hidden trims

Aluminium glass

WC2

T1 - T2

STANDARDS

Opening EN 81-1/2Safety rules

EN 81-21Existing buildings

EN 81-41Impaired mobility

EN 81-71Vandal resistance lifts

EN 81-72Firefighters

lifts

EN 81-20/50Safety rules ASME A17.1

Cat. I Cat. IIC2

T1 - T2

LIFT APPLICATION Door cycles per year: Up to 2.500.000.Traffic peak of the door: Up to 360 cycles per hour.

Traffic lift speed: Up to 6 m/s.

Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.

www.fermator.com3 Robusta PM

Door configuration

SAFETY DEVICES

Opening Photocell Photoelectric barrier Safety edge Emergency power supplyStatic Dynamic* Dynamic deep** VF5+ VF6

C2 T1 - T2

* Safety barrier 10 or 15 mm deep.** Safety barrier 45 mm deep for T1 - T2, 30 mm for C2.

PANEL REGULATION SUPPORT AND PANEL GUIDE

Type of panel regulation support Direct fastening

Type of panel guide Plus

COMPATIBILITY

±030 130130

260

150

130

260

390

AFO: HL + 220

HL

H

MO

TOR

Case Robusta landing doorCoupling Symmetrical clutch

Unlocking zone +130 / -130Toe guard type Big

H 750Thickness 1,5

Range AllT2 opening shown.

If not otherwise indicated all dimensions in mm.

Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.

www.fermator.com 4Robusta PM

T2 operator

ELECTRONIC MODULEType VF5+ and VF6.

Adjustable parameters via PC / Console.Working signals available From 12 V to 240 V AC/DC or with BUS CAN.

Opening speed Up to 1 m/s (Regulable).Closing speed Up to 0,4 m/s. Auto-adjustable directly with the panel weight.

Re-opening Integrated with auto-adjustable cycles.

OTHER FEATURESNoise level < 51 dB.Total weight Reference: T1 PL 800 mm HL 2.000 mm with sheet metal panels - 99,5 kg.

Maximum moving mass 360 kg.Locking device Robusta Restrictor.

INSTALLATIONPre-adjusted and tested to simplify the installation.

Frontal concept, all parts within the sill projection, allows fixing directly to the front or by an adjustable range of brackets.

Technical features

DRIVEType Synchronous brushless permanent magnets motor.

Efficiency 80 %.Consumptions Standby 4W / Average per cycle 50 W.Transmission Geared. PL 600 - 1.829 mm. STD8 belt.

www.fermator.com5 Robusta PM

N

RR

C= =

1938

0

150

14

283

150

150

200

200

254

50325 25796,5

50 x

4

4

90595

50 x n

120120

9510

090

9560

30

6

6

95

+100

-50

254

19

20

= =

180

248

26065 410 210 225

≥ 35

PL

HL

+ 4

00

HL

HL

+ 16

PL

2PL + 100

PL/2 + 30

HL

+ 22

0

HL

+ 22

0

PL/2 PL/2

WW

Panel full open Panel full open

CARFLOOR

Con

cent

ricØ

92

Ecce

ntric

Ø 2

6

H

FIXING BRACKETRANGE

SILL DETAIL

MECHANICAL DETAILS

Technical drawing 2 panel centre parting door

95 mm sill

thickness5

thickness3

Required only with emergency supply.C Total operator length (track length + 50 mm). See page 8.N Recomended vertical fixing point for bracket.R Recomended positions for operator lower fixations.W Panel projection out of the operator with door fully open. See page 8.- If not otherwise indicated all dimensions in mm.

Notes:

www.fermator.com 6Robusta PM

N

RR

196

20

180

C

273

380

1415

0 4

95

95905

619

H

32

60

30

9510

095

95

50650 390

52150

120 120

20

248

≥ 35

+100

-50

283

254

Panel full open

W

50325 25

768,515

0

200

150

200

50 x

4

PL

HL

+ 16

HL

HL

+ 40

0

HL

+ 22

0

PL + 52

2PL + 100

PL

PL650

PL

HL

+ 22

0

Con

cent

ricØ

92

Ecce

ntric

Ø 2

6

CARFLOOR

H

Technical drawing 1 panel side opening door

95 mm sill

thickness5

thickness3

FIXING BRACKETRANGE

MECHANICAL DETAILS

SILL DETAIL

Required only with emergency supply.C Total operator lenght (Track length + 50 mm). See page 8.N Recomended vertical fixing point for bracket.R Recomended positions for operator lower fixations.W Panel projection out of the operator with door fully open. See page 8.- If not otherwise indicated all dimensions in mm.

Notes:

www.fermator.com7 Robusta PM

N

RR

V

T

C

20

380

4

180

19 130

40 80

6

55 125

130

273

619

32

+100

-50

≥ 35

215==

==

50250

130

9010

013

060

30

52

120 12020

248

14254

Panel full open

W

150

283503861,5

25

25

150

200

150

200

50 x

4

PL

1,5PL + 100

HL

+ 16

HL

+ 40

0

HL

HL

+ 22

0

HL

+ 22

0

PL

PL

PL

PL/2 + 39

Con

cent

ricØ

92

Ecce

ntric

Ø 2

6

CARFLOOR

H

Technical drawing 2 panel side opening door

130 mm sill

thickness5

thickness3

FIXING BRACKETRANGE

MECHANICAL DETAILS

SILL DETAIL

Required only with emergency supply. C Total operator lenght (Track lenght + 50 mm). See page 8.N Recomended vertical fixing point for bracket.R Recomended positions for operator lower fixations.T Optional for PL 30 to 48 inches or PL 762 to 1.219 mm.V Only for PL > 36 inches or PL > 914 mm.W Panel projection out of the operator with door fully open. See page 8.- If not otherwise indicated all dimensions in mm.

Notes:

ROBUSTA PM www.fermator.com 8

Total dimension tables

T2PL C WInches mm

- 750 1.218 030 762 031 787

1.2690

- 800 032 813 14,533 838

1.3710

- 850 034 864 035 889

1.4220

- 900 036 914 1337 940

1.5230

- 950 038 965 039 991

1.5740

- 1.000 040 1.016 1441 1.041

1.6760

- 1.050 042 1.067 043 1.092

1.7260

- 1.100 044 1.118 1545 1.143

1.8280

- 1.150 046 1.168 047 1.194

1.8790

- 1.200 048 1.219 13,549 1.245

1.980

0- 1.250 0

50 1.270 051 1.295 26,5- 1.300 34

52 1.321 65,553 1.346

2.133

0- 1.350 0

54 1.372 055 1.397 26,5- 1.400 31

56 1.422 6457 1.448

2.285

0- 1.450 0

58 1.473 059 1.499 27,5- 1.500 29

60 1.524 6561 1.549

2.438

0- 1.550 0

62 1.575 063 1.600 2664 1.626 65- 1.650

2.590

065 1.651 066 1.676 0- 1.700 24

67 1.702 2768 1.727 65- 1.750

2.742

069 1.753 070 1.778 0- 1.800 22

71 1.803 2772 1.829 66

C2PL C WInches mm

- 750

1.676

030 762 031 787 0- 800 24

32 813 5033 838

1.828

0- 850 0

34 864 035 889 50- 900 72

36 9141.980

037 940 0- 950 20

38 965 5039 991

2.1330

- 1.000 040 1.016 041 1.041 49- 1.050

2.285

042 1.067 043 1.092 0- 1.100 15

44 1.118 5145 1.143

2.4380

- 1.150 046 1.168 047 1.194 50- 1.200

2.590

048 1.219 049 1.245 0- 1.250 10

50 1.270 5051 1.295

2.742

0- 1.300 0

52 1.321 053 1.346 50- 1.350 58

54 1.372 10255 1.397 152- 1.400 158

56 1.422 20257 1.448

2.895

101- 1.450 105

58 1.473 15159 1.499 203- 1.500 205

T1PL C WInches mm

- 600 1.218 5924 610 7925 635

1.3710

- 650 626 660 2627 686 78- 700

1.523

028 711 029 737 28- 750 54

30 762 7831 787

1.6760

- 800 132 813 2733 838 77- 850

1.828

034 864 035 889 27- 900 49

36 914 7737 940

1.9800

- 950 038 965 2639 991 44- 1.000

2.133

7840 1.016 041 1.041 0- 1.050 28

42 1.067 7843 1.092

2.2850

- 1.100 044 1.118 2845 1.143 78

Fermator reserves the right to make changes to the specification of the products within this catalogue without prior notice.

General: [email protected]: [email protected] • Brazil: [email protected] • Italy: [email protected] • France: [email protected], [email protected]

China: [email protected] • India: [email protected] • Poland: [email protected] • Germany: [email protected]

Sales contacts