2
product news Fluid sensors and diagnostic systems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition Binary volumetric flow sensors for liquids. Volumetric flow quantities: 15 l/min, 25 l/min, 50 l/min, 100 l/min, 200 l/min. Fast response time ≤ 10 ms. Easy handling: Switch points can be (pre)set continuously. Binary switching output. Pressure range 25 bar. Mechatronic sensor in the coolant circuit of an induction furnace. Mechatronic flow sensor The flow sensor works to the principle of spring-support- ed piston: The piston located in the valve seat in the housing is lifted by the flowing medium against the spring resistance. The piston position is detected via an inductive sensor and is output as a binary signal. The spring resistance leads to reliable reset of the piston to its initial position with decreasing flow. This ensures position-independent installation of the flow sensor and backflow is prevented. The switch points can be easily set and fixed via a setting screw. The robust mechanical design ensures use in harsh environments. The units are maintenance-free. Robust mechatronic flow sensor. 3e Str. SBY 09 26.10.2009 13:55 Uhr Seite 2

Robust mechatronic flow sensor. Fluid sensors and ... · 3e Str. SBY 09 26.10.2009 13:55 Uhr Seite 2. Flow sensors Fluid sensors and diagnostic systems For further technical data

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Robust mechatronic flow sensor. Fluid sensors and ... · 3e Str. SBY 09 26.10.2009 13:55 Uhr Seite 2. Flow sensors Fluid sensors and diagnostic systems For further technical data

product news

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

bus,identification

and control systems

fluid sensors and diagnostic

systems

position sensors

and objectrecognition

Binary volumetricflow sensors for liquids.

Volumetric flow quantities: 15 l/min,25 l/min, 50 l/min, 100 l/min, 200 l/min.

Fast response time ≤ 10 ms.

Easy handling: Switch points can be(pre)set continuously.

Binary switching output.

Pressure range 25 bar.

Mechatronic sensor in the coolant circuit of an inductionfurnace.

Mechatronic flow sensorThe flow sensor works to the principle of spring-support-ed piston: The piston located in the valve seat in thehousing is lifted by the flowing medium against thespring resistance. The piston position is detected via aninductive sensor and is output as a binary signal.The spring resistance leads to reliable reset of the pistonto its initial position with decreasing flow. This ensuresposition-independent installation of the flow sensor andbackflow is prevented.The switch points can be easily set and fixed via a settingscrew. The robust mechanical design ensures use in harshenvironments. The units are maintenance-free.

Robust mechatronic flow sensor.

3e Str. SBY 09 26.10.2009 13:55 Uhr Seite 2

Page 2: Robust mechatronic flow sensor. Fluid sensors and ... · 3e Str. SBY 09 26.10.2009 13:55 Uhr Seite 2. Flow sensors Fluid sensors and diagnostic systems For further technical data

Flow sensors

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

For further technical data please go to: www.ifm.com

Common technical data

Materials (wetted parts)

stainless steel(304C15 / 301),

nickel-plated brass,Pocan; O-ring: NBR

Current rating [mA] 100

TypeSBY

Dimensions

113...123,576,5

32

97...105,5

G4

3

G4

3

3

L+

L

1

4

Wiring diagram

Example SBY332

Pressure loss

[bar]

M12 connector · output function NO · electrical design DC pnp

1...15 0.2...1 ≤ 0.01 ± 5 0.05...0.2 SBY332

Process connection

G 3/4

1...25 0.5...2 ≤ 0.01 ± 5 0.2...0.75 SBY333G 3/4

2...50 1...3 ≤ 0.01 ± 5 0.25...0.8 SBY334G 3/4

5...100 3...6 ≤ 0.01 ± 5 0.1...0.9 SBY346G 1

20...200 5...10 ≤ 0.01 ± 5 0.1...0.2 SBY357G 1 1/2

Application:Liquids

Setting range

[l/min]

Hysteresis

[l/min]

Responsetime[s]

Accuracy

[% of the final value]

Orderno.

Operating voltage [V] 24 DC (-15 % / + 10 %)

Short-circuit protection •

Ambient temperature [°C] 0...60

Medium temperature [°C] 0...85

Switching status [LED] yellow (4 x 90°)

Reverse polarity / overload protection • / •

Repeatability 1 % of the final value

Protection IP 67, III

Connectors and splitter boxes

Type Description Orderno.

M12 socket,2 m black, PUR cable EVC001

M12 socket,5 m black, PUR cable EVC002

M12 socket,2 m black, PUR cable EVC004

M12 socket,5 m black, PUR cable EVC005

M12 socket,2 m orange, PVC cable EVT064

M12 socket,5 m orange, PVC cable EVT001

M12 socket,2 m orange, PVC cable EVT067

M12 socket,5 m orange, PVC cable EVT004

ifm a

rtic

le n

o. 7

5113

77 ·

Prin

ted

in G

erm

any

on n

on-c

hlor

ine

pape

r. ·

We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· 04

.200

9

All data refer to water.

3e Str. SBY 09 26.10.2009 13:55 Uhr Seite 3