RNCFLMIPA2800 Unit State Administration & Replacing PIU

Page 2: RNCFLM IPA2800

2 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Objectives

At the end of this module the participants will be able to:Check working state of RNC units.Change Working state of redundant unitsRestart functional UnitsCorrectly replace and change plug in units when needed

Page 3: RNCFLM IPA2800

3 © Nokia Siemens Networks Presentation / Author / DateFor internal use

SP - EX

WO - EX

TE - EX

SE - OU

SE-NH

Unit States

Page 4: RNCFLM IPA2800

4 © Nokia Siemens Networks Presentation / Author / DateFor internal use

WORKING STATE AND RESTART HANDLING COMMAND <US_>

< ZUSI;

LOADING PROGRAM VERSION 2.13-0

WORKING STATES OF UNITS 2002-05-30 22:32:37

UNIT PHYS LOG STATE INFO

OMU-0 0000H 4002H WO-EX -

OMU-1 0001H 4002H SE-NH -

MXU-0 0012H 4243H WO-EX -

MXU-1 0024H 4243H SE-NH -

...

A2SU-0 > WO-EX -

A2SU-1 > WO-EX -

...

COMMAND EXECUTED

Checking Working States

Page 5: RNCFLM IPA2800

5 © Nokia Siemens Networks Presentation / Author / DateFor internal use

< USI:DMCU,0::FULL:;

WORKING STATES OF UNITS 2009-02-25 12:36:06

UNIT PHYS LOG STATE INFODMCU-0 WO-EX -DMPG-0 000CH 4470H WO-EX -DSP-0 WO-EX -DSP-1 WO-EX -

DMPG-1 0010H 4471H WO-EX -DSP-2 WO-EX -DSP-3 WO-EX -

DMPG-2 0011H 4472H WO-EX -DSP-4 WO-EX -DSP-5 WO-EX -

DMPG-3 0012H 4473H WO-EX -DSP-6 WO-EX -DSP-7 WO-EX -

NUMBER OF UNITS DISPLAYED = 13COMMAND EXECUTED

Checking Working States of Child Unit

Page 6: RNCFLM IPA2800

6 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Main state Full state Name

WO WO-EX Working, executing

WO-RE Working, restarting

BL BL-EX Blocked, executing

BL-ID Blocked, idle

BL-RE Blocked, restarting

SP SP-EX Spare, executing

SP-UP Spare, warming-up

SP-RE Spare, restarting

TE TE-EX Test state, executing

TE-RE Test state, restarting

SE SE-OU Separated, out of use

SE-NH Separated, no hardware

Unit SubStates

Page 7: RNCFLM IPA2800

7 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Working state changed for:• Configuration• Testing• Clear up error conditions

Faulty units in WO-EX should be replaced as soon as possible

Changing Working State

Page 8: RNCFLM IPA2800

8 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Switchover possible if unitsin 2N or N+1 redundancyIf unit has ongoing tasks, FCD parameter must beusedIn N+1 units, working statechange from SP to WO doesnot cause switchover

WO-EX SP-EX

SP-EXWO-EX

Activating Switchover

Page 9: RNCFLM IPA2800

9 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Diagnosing faulty units• Change unit state to TETaking out of use• Change unit state to SE-

NH• Transition procedure must

be followed• If tasks ongoing, FCD must

be used• Unit can be removed when

power is off

Working state LED displayWO-EX GreenWO-RE Green blinkBL-EX GreenBL-ID GreenBL-RE Green blinkSP-EX OrangeSP-UP Green blinkSP-RE Green blinkTE-EX Red blinkTE-RE Red blinkSE-OU RedSE-NH None

Taking a Unit Out of Use

Page 10: RNCFLM IPA2800

10 © Nokia Siemens Networks Presentation / Author / DateFor internal use

BL SETEWO

SP SETEWO

2N or N+1 redundancy:

SN+ or NO redundancy:

Changing of working states (USC)

Page 11: RNCFLM IPA2800

11 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Restarting unit• MML command - ZUSURestarting system• MML command – ZUSSLoading modes• File loading

– Immediate loading; F=IMM

• Code loading– From memory; default– Total code loading; C=TOT– Total code loading from disk; C=CDSK

USU:ICSU,1::C=DSK,F=IMM,;

RESTART REQUESTED IN ICSU-1

CONFIRM COMMAND EXECUTION: Y/N ? Y

RESTART ORDERED UNIT = ICSU-1

COMMAND EXECUTED

Restarting

Page 12: RNCFLM IPA2800

12 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Bring the plug-in units in their inner packages close to the cabinets and place them on an ESD-protected surface.

Connect your ESD wrist strap to the earth bonding point in the cabinet you are working on.

ESD Precautions

Page 13: RNCFLM IPA2800

13 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Check that the unit working state is SE-NH (USI)

• ZUSI:<unit type>;Change the working state if

the unit working state is not SE-NH, (USC)

• ZUSC:<unit type>,<unit index>:<working state>;

or

WO-EX BL-EX BL-ID

SE-NH SE-OU TE-EX

(by user)

(by user) (by user)

(by system)

(by user)

WO-EX SE-NHSE-OUTE-EX

(byuser)

(byuser)

(byuser)

or

WO-EX SP-EX TE-EX

SE-NH SE-OU

(by user)

(by user)

(by system)

(by user)

Ensuring Correct Unit State

Page 14: RNCFLM IPA2800

14 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Remove any cable(s) from thefront panel of the plug-in unit

Unscrew locking screws on thefront panel (A)

Open two insertion/extractionlevers on the front panel (B)

Remove the plug-in unit fromthe subrack (C)

A

B C

Removing the Unit

Page 15: RNCFLM IPA2800

15 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Insert the spare plug-in unit in its location (A)

Close the insertion/extraction levers on the front panel of the plug-in unit (B)

Close the locking screws carefully (C)

Insert cable(s) back to the front panel of the plug-in unit if there were any

A

C

B

Installing PIU

Page 16: RNCFLM IPA2800

16 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Set the functional units of a plug-in unit to the SE-OU working state (USC)

- ZUSC:<unit type>,<unit index>:SE;Set the functional units of a plug-in unit to the TE working

state (USC)• ZUSC:<unit type>,<unit index>:TE;• Check that the repair operation was successful by

starting the total diagnosis of the unit (UDU)• ZUDU:<unit identification>;

Testing the Unit

Page 17: RNCFLM IPA2800

17 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Set the unit to the SP or WO working state (USC)• ZUSC:<unit identification>:<working state>;

Check that the alarm disappears, if necessary (AAP)• ZAAP;

Finishing Installation