6
RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT For use with the 3M™ Jupiter™ Powered Respirator

RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

RJS RESPIRATORY & CHEMICAL PROTECTIVE SUITFor use with the 3M™ Jupiter™ Powered Respirator

Page 2: RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

Applications:• Liquid chemical and solvent handling • Hazardous waste remediation• Asbestos abatement• Petrochemical applications• Pharmaceutical manufacture• Laboratories• Agriculture• Infection control• Mass decontamination• Hospital first receivers• Emergency Medical Service• Casualty Transport• Triage

The RJS 300 Chemical Respirator Suit is a one-piece Type 3 chemical protective suit for use in hazardous industrial and emergency response environments.Manufactured from Chemprotex™ 300, a high-performance, lightweight, chemical barrier fabric, the RJS suit protects the wearer against a broad range of industrial chemicals and other agents found in civil emergency situations.

RJS Respiratory and Chemical Protective Suit

Page 3: RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

Suit Features:• Air drawn through the filters enters through a

breathing tube in the hood and exits through exhaust valves in the knees, providing a cooling air stream across the body

• Chest zip with double storm flap and VELCRO® brand hook and loop closure - no taping required to seal

• Chemically protective laminated glove welded to the suit material, with elasticated over-sleeve for use with gloves providing mechanical protection without the need for taping of gloves

• Integral sock foot with elasticated outer leg allows the user to choose their own boots without compromising the level of protection

• Head-up display in the hood indicates turbo status, hours used and any warnings

• Suit achieves a Type 3 classification without the need for taping at the zip flap, sleeves or ankles, simplifying the donning & doffing process

*Additional testing to EN 1073-1:1998 demonstrated that a Total Inward Leakage (Respiratory Zone of less than 0.002%) was achieved, relating to a Nominal respiratory Protection Factor of 50,000.

Certification:

TYPE 3, EN 14605:2005+A1:2009 Liquid-Tight Chemical Protective ClothingTYPE 4, EN 14605:2005+A1:2009 Spray-Tight Chemical Protective ClothingTYPE 5, EN 13982-1:2004+A1:2010 Particulate Protective ClothingTYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective ClothingEN 14126:2003 Protective Clothing Against Infective AgentsEN 12941:1998+A2:2008 APF 40, NPF 500* Respiratory Protective Devices

Infective Agents

Type 3 Type 4 Type 5 Type 6

EN 1149-5Antistatic

EN 1073-2Radioactive Particles

EN 14126Infective agents

EN 13034Type 6, Spray-tight

EN ISO 13982-1 Type 5, Particle-tight

EN 14605 Type 4, Spray-tight

EN 14605 Type 3, Liquid-tight

EN 943Gas-tight and non-gas tight

EN 1149-5Antistatic

EN 1073-2Radioactive Particles

EN 14126Infective agents

EN 13034Type 6, Spray-tight

EN ISO 13982-1 Type 5, Particle-tight

EN 14605 Type 4, Spray-tight

EN 14605 Type 3, Liquid-tight

EN 943Gas-tight and non-gas tight

EN 1149-5Antistatic

EN 1073-2Radioactive Particles

EN 14126Infective agents

EN 13034Type 6, Spray-tight

EN ISO 13982-1 Type 5, Particle-tight

EN 14605 Type 4, Spray-tight

EN 14605 Type 3, Liquid-tight

EN 943Gas-tight and non-gas tight

EN 1149-5Antistatic

EN 1073-2Radioactive Particles

EN 14126Infective agents

EN 13034Type 6, Spray-tight

EN ISO 13982-1 Type 5, Particle-tight

EN 14605 Type 4, Spray-tight

EN 14605 Type 3, Liquid-tight

EN 943Gas-tight and non-gas tight

Respiratory Protection

EN 1149-5Antistatic

EN 1073-2Radioactive Particles

EN 14126Infective agents

EN 13034Type 6, Spray-tight

EN ISO 13982-1 Type 5, Particle-tight

EN 14605 Type 4, Spray-tight

EN 14605 Type 3, Liquid-tight

EN 943Gas-tight and non-gas tight

Sock foot & outer elasticated leg

Elasticated outer sleeve & inner glove

Page 4: RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

Benefits:• Lightweight suit design with backpack

mounted powered respirator provides excellent wearer comfort

• Respirator and loose-fitting hood provide cooling air over the head and through the suit, reducing heat stress and making the wearer more comfortable and better able to focus on tasks

• The loose-fitting hood design provides high protection without the need for a tight-fitting face piece, which means:

1. Many wearers feel less constricted2. Can be used by wearers with facial

hair or glasses3. Training needs are reduced4. Face-fit testing is not required

• Compared to a gas-tight suit with SCBA, the suit and respirator is significantly lighter and more comfortable, with far greater operational duration.

• Greater freedom of movement and operational independence than when using air-fed suits with an airline

• In medical and emergency response applications the clear wide-view visor provides reassurance to casualties and victims by allowing easier, friendly ‘whole-face’ communication

Page 5: RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

3M™ Jupiter™ Powered RespiratorThe Jupiter turbo unit in the RJS suit provides respiratory protection against a wide range of contaminants. An ergonomically designed padded backpack ensures the unit’s low weight is comfortably carried on the user’s shoulders. As a result, the Jupiter powered air turbo unit is comfortable enough to wear for entire work shifts. • Head-up display indicates turbo status,

hours used and warnings• Audible and visual low airflow alarm• Easy to adjust and maintain• IP53 rating. Suitable for use in a

decontamination shower.• Choice of battery packs with up to 8 hours

operational use• Range of filters available offering protection

from particulate, organic vapour, inorganic and acid gases and ammonia.

3M™ Jupiter™ Filter Options• P R - Particulates• A2P R - Organic vapours and particulates• A2BEK1P R - Combination organic

vapours, inorganic and acid gases & ammonia and particulates

• ABE1P R - Combination organic vapours, inorganic and acid gases and particulates

3M™ and Jupiter™ are trademarks of the 3M CompanyVELCRO® is a registered trademark of Velcro Industries B.V.Chemprotex™ and Respirex™ are Trademarks of Respirex International Limited

Page 6: RJS RESPIRATORY & CHEMICAL PROTECTIVE SUIT · Particulate Protective Clothing TYPE 6, EN 13034:2005+A1:2009 Limited Spray-Tight Chemical Protective Clothing EN 14126:2003 Protective

Item Description Pack QtySuitsRJS300-X* RJS 300 Chemical Protection Suit (Blue) 1Powered RespiratorF01124 Turbo, Backpack, Head-up Display, Filter Retainers & Breathing Tube 1BatteriesF01128 Single-use 4-Hour Battery - Bat-22 1F01126 Rechargeable 4-Hour Battery 1F01127 Rechargeable 8-Hour Battery 1FiltersF01131 Particulate P R Filters (pairs) 12F01133 A2P R Filters (pairs) 6F01132 A2BEK1P R Filters (pairs) 6F01134 ABE1P R Filters (pairs) 6Spares & AccessoriesF01136 Back Pack 1F01137 Breathing Tube 3

F01129 Intelligent Battery Charger - CHG-02 1F01130 Intelligent 10-Station Battery Charger 1F00935 Filter Retainers (pair) 1

* Substitute X for the size, e.g. S, M, L, XL, XXL

RJS Respiratory and Chemical Protective Suit - System Components

N.B. There are uses, environments and chemicals for which this garment is unsuitable. It is the responsibility of the user to review available data and verify that the garment is appropriate for the intended use and meets all specified government industry standards.

For chemical permeation data for the Chemprotex™ range of fabrics, please visit the Respirex website.

Respirex International Limited Unit F, Kingsfield Business Centre, Philanthropic Road, Redhill, Surrey, RH1 4DP, United Kingdom

: www.respirexinternational.com: +44 (0)1737 778600 : [email protected]

© Respirex International Limited, 2016