9
Company: ____________________________________________ Job Name: _______________________________________________ Contact: ______________________________________________ Job Location: ____________________________________________ Phone: _______________________________________________ Fax: ____________________________________________________ Address: _____________________________________________ E-Mail: __________________________________________________ _____________________________________________________ Today’s Date: _____________________________________________ City/State/Zip: _________________________________________ Quote Due Date: __________________________________________ New Construction Modernization Capacity: Class of Loading: Gross Weight: Travel: Speed: ________ ________ ________ ________ ________ Landings: Front Openings: Rear Openings: Side Openings: _______ _______ _______ _______ Hatch Width: Hatch Depth Overhead: Pit Depth: _____________ _____________ _____________ _____________ Voltage: Phase: __________ __________ * NEMA 1 * NEMA 1 ________________________________________ ________________________________________ * INDICATES STANDARD MATERIALS Other: Other: Electrical Rating: Hoistway: Machine Room: HOISTWAY DETAILS Include this section in quote Platform: Width: __________________ Depth: ________________ Sub-Floor Material: *2 Layers 15/32 Plywood Finish Floor Thickness: ________________ (Finished Floor by Others) Weight: ____________ Other ___________________ Sling, Brace Rods, Fastener Package Pit Assembly Spring Buffers Oil Buffers Rail Guides: Rail Brackets Fishplates Car Top Inspection Station w/Fire Service 3 Maintenance Manuals Other Quantity: ____________________ Other ________________________________________ Seismic Application Zone: ________________ Government Submittal Package Special Paint (Other than MEI Blue) Certified Engineer Stamp on Drawings Rail Lubricators Platform Isolation Full Partial Isolation Standards: 6000 lbs. or Less - Fully Isolated Over 6000 lbs. - Partially Isolated Slide * Roller Swivel Other ________________________________________ Engineering / Layout Drawings RFQ FORMS Traction Passenger Elevator Package TRACTION MACHINE Include this section in quote Machine Location: Roping: Drive: Equipment: Other: Overhead 1:1 VV/VF/AC Machine Main Ropes Governor / Tension Weight Car Safety Counterweight Safety Counterweight Frame _______________________________________________________________________________________________ _______________________________________________________________________________________________ Basement 2:1 DC-SCR Hoist Motor Governor Rope Type A Type A Counterweight Filler Weights Sheaves Type B Type B ( Required if Occupied Space Below Hoistway) DC/MG Set Encoder / Tachometer Rope Shackles ( Wedge-Type) When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

Company: ____________________________________________ Job Name: _______________________________________________Contact: ______________________________________________ Job Location: ____________________________________________Phone: _______________________________________________ Fax: ____________________________________________________Address: _____________________________________________ E-Mail: _______________________________________________________________________________________________________ Today’s Date: _____________________________________________City/State/Zip: _________________________________________ Quote Due Date: __________________________________________

New ConstructionModernization

Capacity:Class of Loading:

Gross Weight:Travel:Speed:

________________________________________

Landings: Front Openings:Rear Openings:Side Openings:

____________________________

Hatch Width:Hatch Depth

Overhead:Pit Depth:

____________________________________________________

Voltage:Phase:

____________________

* NEMA 1* NEMA 1

________________________________________________________________________________

* INDICATES STANDARD MATERIALS

Other:Other:

Electrical Rating: Hoistway:Machine Room:

HOISTWAY DETAILSInclude this section in quotePlatform: Width: __________________ Depth: ________________ Sub-Floor Material: *2 Layers 15/32 Plywood

Finish Floor Thickness: ________________ (Finished Floor by Others) Weight: ____________ Other ___________________Sling, Brace Rods, Fastener PackagePit Assembly Spring Buffers Oil BuffersRail Guides:Rail BracketsFishplatesCar Top Inspection Station w/Fire Service3 Maintenance Manuals Other Quantity: ____________________

Other ________________________________________

Seismic Application Zone: ________________ Government Submittal Package Special Paint (Other than MEI Blue) Certified Engineer Stamp on Drawings

Rail Lubricators Platform Isolation Full Partial Isolation Standards: 6000 lbs. or Less - Fully Isolated

Over 6000 lbs. - Partially Isolated

Slide * Roller Swivel

Other ________________________________________

Engineering / Layout Drawings

RFQ FORMSTraction Passenger Elevator Package

TRACTION MACHINE

Include this section in quoteMachine Location:

Roping:Drive:

Equipment:

Other:

Overhead 1:1 VV/VF/AC

MachineMain RopesGovernor / Tension WeightCar SafetyCounterweight SafetyCounterweight Frame

______________________________________________________________________________________________________________________________________________________________________________________________

Basement2:1DC-SCRHoist MotorGovernor Rope

Type AType ACounterweight Filler Weights

SheavesType BType B ( Required if Occupied Space Below Hoistway)

DC/MG SetEncoder / TachometerRope Shackles ( Wedge-Type)

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

John Castano
initiator:[email protected];wfState:distributed;wfType:email;workflowId:b7b55126856c45a2a7a001098e8a8c4a
Page 2: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

Simplex/Group (2 or more cars) :Elevator ID (car label) :Elevator Safety Code:

Number of Stops/Openings:Rear Openings/@ Landings:Total Travel (ft):

Capacity (lbs) :Car Speed (fpm) :

Line Voltage (Vac, 3Ø, 60Hz) :Hoist Motor HP:Hoist Motor Voltage:Hoist Motor FLA:Hoist Motor FL RPM:

ft.

Machine Type (Geared/Gearless):Machine Model, Type or Style:

Machine Location (OH/MRL/B):Drive Type (AC-CL-VVVF/DC-CL-SCR):

*Door Operator Model:Door Mfg. (GAL/MAC/Otis...):

Number of COP's (1-4):

*Standards - Door interface to the TOC board requires a solid state door operator / Fixtures must be 24VdcController Features & Accessories:

Emergency Power Overlay Pit Flood Switch Operation

Number of Hall Call Risers:

Security-Car Call Key Floor Lockouts

Isolation Transformer

EMT (Massachusetts) Service Sabbath OperationEnclosure Interior Lighting (Main Encl.) Security-EC Basic (Using COP buttons)

Harmonic Filter, 3 Phase (AC Only) Serial PI Driver (3-Wire): CE Microcomm

Sales quote is subject to revision, if the final engineering data form values differ from the information provided.Monitoring: Web-Interact LiftNet Interface Machine Room PC Remote Lobby PC Printer

Hoistway Special Rating: NEMA 12 NEMA 4 NEMA 4XPixel Traveler Cable: Kellem Grips Quantity:

Motor/Output Choke Final Limit Switches (Mechanical)

Machine Room Special Rating: NEMA 12 NEMA 4 NEMA 4X

Load Weighing Device Spare Pixel Board SetLoad Weighing Interface

Serial PI Driver (3-Wire): Emotive

Governor Set/Reset Solenoids Security-Hall Call Card ReadersHall Lanterns & Chimes Security-Hall Call Key Floor Lockouts

Fire Panel / Lobby Panel InterfaceGFCI Duplex Outlet (Main Enclosure)

Machine Brand:Motor Mounting (Foot/Flange) :

Swing Car Operation (IR)

AC Regenerative DriveAttendant (Porter) Service Battery Power Rescue System Brownout Circuit (3Ph. Voltage Monitor)Cab Fan & Light Timed OperationCar to Lobby SwitchCode Blue (Hospital Service)Cross Registration PanelDoor Hold OperationEarthquake OperationEMC/RFI Line Filter (AC Only) Emergency Power Operation

Additional Information:

Standard Included Features: NEMA 1 Enclosure, P-TOC-BOX (with pre-wired cartop inspection station) & Cartop Mounting Kit, Landa Absolute Positioning System (Stainless Steel Tape) & Cartop/Hoistway Mounting Kits, CAN Serial Communication to COP and Hall Network, Hall Network CAT5 Cable Package.

Hoist Motor Frame Size:

Security-Car Call Card Readers

A17.1-

CONTROLLERSInclude this section in quote

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

Page 3: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

Transmit to Lift Solutions ! Fax 425 / 671-0758 ! Phone 360 / 862-8328 ! 3 of 11LSI RFQ Hydraulic Modernization rev 12-18-07 © 2007 Lift Solutions Inc

Indicate Pushbutton Type:

Round Buttons:

! Square ! Half MoonBraille Type: ! Round

Auxiliary COPType: ! Main COP !

COP Style: ! Applied panel

COP Finish:

! Dover Impulse Swing Return

! #8 Stainless

COP Lamp Voltage: ! 24 ! Multivolt (6v-120v)COP Engraving: ! No Smoking

! Additional COP engraving: _______________________________________________

Car Labels ________ ________ ! Same as #___

________ ! Same as #___

________ ! Same as #___

Yes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | No

Yes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | No

Yes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | NoYes | No Yes | No Yes | No Yes | No

Fire Service Provisions for Future Fire

Service Fan Key Switch

Light Key Switch Independent Service Key Switch

Attendant Operation Emergency Light Test Switch

Hospital Emergency (Code Blue) Inspection Key Switch Keyed Floor Lockouts

Indicate Lockout Floor/s Attendant Cabinet Handsfree Phone Emergency Light Certificate Frame

Phone Jack Intercom Provisions

Card Reader Provisions Voice Annunciation

Digital PI in COP

! BS Series BP Series Dune

You can also print this form, fill it out, and return by fax to (425) 671-0758Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 3

Lift Solutions Fixtures RFQ Form rev 9-22-09 © 2009 Lift Solutions IncWhen completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

- Hinged

***All items in red are Standard COP items.

! #4 Muntz! #4 Muntz! #4 Stainless

F IXTURES – GENERAL (Complete for COP &/or HALL)

FIXTURES – CAR OPERATING PANEL

! #8 Muntz

Include this section in quote

Page 4: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

Transmit to Lift Solutions ! Fax 425 / 671-0758 ! Phone 360 / 862-8328 ! 4 of 11LSI RFQ Hydraulic Modernization rev 12-18-07 © 2007 Lift Solutions Inc

!!!! FIXTURES – HALL STATIONS

Hall Station Type: ! Flush (incl Box) ! Flush (reuse existing Box) ! Digital Hall Station PI’s: ! No ! Yes @ Floors: __________________________________Hall Station Braille: ! Yes ! NoHall Station Lamp Type: ! LED (standard)

! Hall Station Finish: ! #4 Stainless ! #4 Muntz ! #8 Stainless ! #8 MuntzHall Station Engraving: ! California – Man & Flames ! ANSI – 3 Flames

! Other / Special: _______________________________________________

!!!! FIXTURES – LANTERNS

! Car Lanterns ! Hall LanternsLantern Style: ! Horizontal ! Vertical

Finish: ! #4 Stainless ! #8 Stainless ! #8 MuntzArrow Style: ! Triangle ! 3” Round ! Vandal Resistant ! DigitalMounting: ! Standard (incl box) !

!!!! FIXTURES – POSITION INDICATORS

! No arrows! Hall ! with Direction Arrows ! No arrows @ Floors: ____________________________

Finish: ! #4 Stainless ! #4 Muntz ! #8 Stainless ! #8 MuntzMounting: ! Standard (incl box) !

! Digital Hall Position Indicators:! Segmented ! Combo Digital w/ Lanterns @ Floors: ________________________

Fixture Notes: ___________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________

Lift Solutions Fixtures RFQ Form rev 9-8-09 © 2009 Lift Solutions IncTransmit to Lift Solutions ! Fax 425 / 671-0758 ! Phone 360 / 862-8328 ! 4 of 11LSI RFQ Hydraulic Modernization rev 12-18-07 © 2007 Lift Solutions Inc

!!!! FIXTURES – HALL STATIONS

Hall Station Type: ! Flush (incl Box) ! Flush (reuse existing Box) ! Surface Mount Pan ShapedDigital Hall Station PI’s: ! No ! Yes @ Floors: __________________________________Hall Station Braille: ! Yes ! NoHall Station Lamp Type: ! LED (standard)

! 24 ! Multivolt (6v - 120v)Hall Station Finish: ! #4 Stainless ! #4 Muntz ! #8 Stainless ! #8 MuntzHall Station Engraving: ! California – Man & Flames ! ANSI – 3 Flames

! Other / Special: _______________________________________________

!!!! FIXTURES – LANTERNS

! Car Lanterns ! Hall LanternsLantern Style: ! Horizontal ! Vertical

Lamp Voltage: 24 ! MultivoltFinish: ! #4 Stainless ! #8 Stainless ! #8 MuntzArrow Style: ! Triangle

! #4 Muntz! 3” Round ! Vandal Resistant ! Digital

Mounting: ! Standard (incl box) ! Reuse existing box Surface Mount

!!!! FIXTURES – POSITION INDICATORS

! 7" Giotto 2" CE Segmented! Car With Direction Arrows ! No arrows! Hall ! with Direction Arrows ! No arrows @ Floors: ____________________________

Lamp Type LED (standard)Lamp Voltage 24 Multivolt Finish: ! #4 Stainless ! #4 Muntz ! #8 Stainless ! #8 MuntzMounting: ! Standard (incl box) ! Reuse existing box Surface mount! Digital Hall Position Indicators:

! Segmented ! LED ! Combo Digital w/ Lanterns @ Floors: ________________________

Fixture Notes: ___________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________

Lift Solutions Fixtures RFQ Form rev 9-22-09 © 2009 Lift Solutions IncWhen completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

Hall Station Lamp Voltage:

!

!

! !

! ! !

!

FIXTURES - LANTERNS

FIXTURES - HALL STATIONS

FIXTURES - POSITION INDICATORS

Page 5: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

_____ PARAMETER UNIT

_____ CAR DOOR HANGER

_____ CAR DOOR CLUTCH

HAND HELD OPERATOR MOUNTED

_____ INFRARED CURTAIN

_____ HATCH DOOR HANGER

_____ DOOR CLOSER

(INCLUDES TRACK, AND HANGERS)

_____ INTERLOC K (INCLUDES R OLLER RELEASE)

HARMONIC OPERATORS

SPRING (LINKAGE) REEL(SPIRATOR) (S/S & C/P DOORS ONLY)

WITH ZONE LOCK WITHOUT ZONE LOCK

FORMULA SYSTEM-FCU47 JANUS 3D

TRI-TRONICS WATERPROOF

HEADER HEIGHT: ________ (DISTANCE FROM TOPOF CAR DOOR TO OPERATOR)

SINGLE PHASE 500VA SUPPLY RQD.

MOVFRII MODL MOHL MOVFE-HH

LINEAR OPERATORS (INCLUDES DRIVE ARM & GATE SWITCH)

MONXT MOVFE-HL

(INCLUDES HEADER, TRACK, AND HANGERS)

_____ EMERGENCY KEY _____ KEY BOX

QTY PRODUCT _____

DOOR OPERATOR

R.H. C.P.L.H. S.H.

RIGHT HAND LEFT HAND CENTERPARTING

SWING HATCH

S/S 2/SP 3/SP

NEW INSTALLATION MODERNIZATION (SURVEY SHEETS REQUIRED)

_______________________________ EXISTNG EQUIPMENT MANUFACTURER

REPLACING DOORS? CAR HATCH

DOOR OPENING ________ X ________ WIDTH HEIGHT

RIGHT HANDLEFT HAND

LANDINGS: FRONT

REAR

220 V 115 V

FLUSH MOUNTED

SURFACE MOUNTED

#4 SATIN

#8 MIRROR

STAINLESS STEEL

MUNTZ METAL

ADDITIONAL EQUIPMENT INFO ______________________________________________________________________________________________________________________________________________________________________________________________________________________________________

CAB MFG: NEW EXISTING ENTRANCE MFG: NEW EXISTING CONTROLLER MFG: NEW EXISTING

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

DOOR OPERATORInclude this section in quote

Page 6: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4You can also print this form, fill it out, and return by fax to (425) 671-0758

LSI Traction Passenger Elevator Package RFQ Form rev 12-04-09 © 2009 Lift Solutions

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

CAB – COMPLETE

Car Labels ________ ________ Same as #___

________ Same as #___

________ Same as #___

ft/in ft/in ft/in ft/in ft/in ft/in ft/in ft/in ft/in ft/in ft/in ft/in

Elevator Type (Passenger/Freight) If Freight, Loading Requirements

Platform Width Platform Depth

Cab Height

Car Door Type (select one) 1spd SS 1spd SS 1spd SS 1spd SS2spd SS 2spd SS 2spd SS 2spd SS3spd SS 3spd SS 3spd SS 3spd SSCntr Open Cntr Open Cntr Open Cntr Open2spd CO 2spd CO 2spd CO 2spd CO

ft/in ft/in ft/in ft/in ft/in ft/in ft/in ft/in

Yes | No Yes | No Yes | No Yes | No

Door Operator Mfg / Type Car Door Opening Width/s

Car Door Opening Height/sDoor Finish

Sill Finish New sling?

New platform? Yes | No Yes | No Yes | No Yes | No

ENTRANCE MODULEInclude this section in quote

Jamb Construction:Jamb Finish:Door Finish:

Transom:Sills:

Other:Miscellaneous:

* Bolted Knockdown* Enamel / Primed* Enamel / Primed* Standard* Aluminum____________________________________________________________________________________________Sound-Deaden DoorsGroutless Sill Angles

Hoistway Wall Thickness: ” Block DrywallWelded / MiteredStainless SteelStainless Steel

Other: ___________________________BronzeBronze

#4#4

#8#8

FlushNickel-Silver

Off-Set ”Bronze

Include this section in quote

Page 7: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

ELEVATOR INTERIORS: EDGING OPTIONS

□ “L” Binder (11 GA) □ “J” Mitered Binder

ELEVATOR INTERIORS: PROJECT INFORMATION

Date:_____________________________Project Name: _________________________________________

Requested By: ___________________________________ Company Name: ________________________________

Building Type: □ Residential □ Corporate □ Medical □ Educational □ Hotel □ Other: __________________

Job Type: □ Existing Shell □ Supply New Shell

Scope: □ Cab Interior Only □ Cab Interior & Fronts

Capacity (lbs): □ 2000 □ 2500 □ 3000 □ 3500 □ 4000 □ 4500 □ 5000 □ Other: _________________

Opening Type: □ Center Opening □ Side Opening

Door Speed: □ Single Speed □ Double Speed

Sill Material: □ Aluminum □ Stainless Steel □ Nickel SilverNumber of Cabs: ____________________________

ELEVATOR INTERIORS: LAYOUT OPTIONS

Back Wall Choice: ________________________________ Side Wall Choice: ________________________________

Dorado Tucana Carina

A-LookTM C-LookTM

□ A-LookTM Binder □ C-LookTM Binder

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

Include this section in quote

initiator:[email protected];wfState:distributed;wfType:email;workflowId:bdf9d78c64004881babcca007d0ccb0b
Page 8: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

ELEVATOR INTERIORS: HANDRAIL OPTIONS

□ None □ Back Wall □ Side Wall □ All Walls

□ Round 1 ½" □ Flat Bar 2" x ¼" □ Flat Bar 3" x ¼"

ELEVATOR INTERIORS: CEILING OPTIONS

□ Pandora

□ Heavy Traffic (below handrail) □ Other: _________________________________

Floor Tiling: □ Standard MAD Tiles (Regal) □ Other: _________________________________

□ None□ Europa □ Titan (Perforated Ceiling)□ Phoenix

Bend: □ Entrance Only Return End □ All Return Ends

ELEVATOR INTERIORS: BUMPER OPTIONS

□ None □ Back Wall □ Side Wall □ All Walls□ Flat Bar 3" x ¼" □ Flat Bar 6" x ¼"

Bend: □ Entrance Only Return End □ All Return Ends

ELEVATOR INTERIORS: FINISH OPTIONS

Finish: □ Standard MAD Laminate (See Design Guide) □ Royal Deco 2WL □ Royal Deco 5WL

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758

Page 9: RFQ FORMS Traction Passenger Elevator Package...Transmit to Lift Solutions - When completed, click “Submit Form” at top of page 1. - 2 of 4 You can also print this form, fill

ELEVATOR DATAEnter floor markings &

travel for each floor served

Overhead

Pit DepthFront Rear

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

6

5

4

3

2

1

Arch. Prints Available? Yes No

No Power Disconnects No Inserts

No Machine Beams

STANDARD EXCEPTIONSNo Rail Mounting Beams No Finish Floor Covering

No Hall Fire Signs No Smoke Detection

No Rail Backing

SPECIAL REQUIREMENTSSpecial Code(s): Explain: ______________________________________________________________________________________ WBE/MBE: Explain: _________________________________________________________________________________________ Buy American Act: Explain: ____________________________________________________________________________________ U.S. Steel: Explain: ___________________________________________________________________________________________ Federal Acquisition Regulations: Explain: _________________________________________________________________________

When completed, please submit to Lift Solutions. Email to [email protected] or Fax to (425) 671-0758