1 ENERGY SAVINGS THROUGH IMPROVED AERATION EFFICIENCY PRESENTED BY: DAVID T. REDMON PRESIDENT – REDMON ENGINEERING COMPANY

Redmon_Energy Savings Through Improved Aeration Efficiency

Embed Size (px)

Citation preview

Page 1: Redmon_Energy Savings Through Improved Aeration Efficiency

1

ENERGY SAVINGS THROUGH IMPROVED AERATION

EFFICIENCY

PRESENTED BY: DAVID T. REDMONPRESIDENT – REDMON ENGINEERING COMPANY

Page 2: Redmon_Energy Savings Through Improved Aeration Efficiency

TYPICAL WWTP ENERGY USE

HVAC - 11%

PUMPING AND OTHER – 34%

AERATION – 55%

Aeration is the largest energy use for most WWTP’s

Page 3: Redmon_Energy Savings Through Improved Aeration Efficiency

RECENT HISTORY OF AERATION

Prior to the 1970’s energy was cheap (approx. 2.0¢ kwh), as a result, many aeration systems were inefficient.

Consequently Mechanical and Coarse Bubble Aeration Systems which have relatively low maintenance requirements were very prevalent.

In 1974 the Arab oil embargo hit, resulting in :

• rising energy costs

• movement towards more energy efficient aeration systems.

Page 4: Redmon_Energy Savings Through Improved Aeration Efficiency

1978 LA COUNTY CLEAN WATER TESTING

Testing of various generic diffused aeration systems. The goal was to identify those systems that would be energy efficient for the next 20 years.

Systems Tested: Norton Ceramic Domes - Grid FMC/ Pearlcomb Tubes – Spiral Roll Penberthy Jets – Cluster and Directional Mix Kenics Static Tubes – Grid Placement Sanitaire Coarse Bubble – Grid and Spiral Roll FMC Coarse Bubble – Spiral Roll Envirex Coarse Bubble – Spiral Roll Bauer Coarse Bubble – Spiral Roll

Page 5: Redmon_Energy Savings Through Improved Aeration Efficiency

RECENT HISTORY

LA COUNTY CLEAN WATER TESTING.

At Whittier Narrows, CA in 20x20 ft test tank, at 10, 15, 20 and

25 ft depths

Three power levels between 0.3 and 1.5 HP/1000-cuft.

Results presented in Houston at the 1980 WWEMA meeting.

Page 6: Redmon_Energy Savings Through Improved Aeration Efficiency

WHITTIER NARROWS CLEAN WATER TEST RESULTS AT THE 15 FT DEPTH STANDARD OXYGEN TRANSFER EFFICIENCY VS DELIVERED POWER DENSITY

0

5

10

15

20

25

30

35

40

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2

DELIVERED POWER DENSITY (HP/1000 FT3)

STA

NDA

RD O

XYG

EN T

RANS

FER

EFF

(%)

NORTON

KENICS

PENTECH

FMC TUBE

SANITAIRE

BAUER

ENVIREX

FMC CB

Whittier Narrows Clean Water

Page 7: Redmon_Energy Savings Through Improved Aeration Efficiency

WHITTIER NARROWS CLEAN WATER TEST RESULTS AT THE 15 FT DEPTHSTANDARD AERATION EFFICIENCY VS DELIVERED POWER DENSITY

0

1

2

3

4

5

6

7

8

9

10

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2

DELIVERED POWER DENSITY (HP/1000 FT3)

STA

NDA

RD W

IRE

AER

ATI

ON

EFFI

CIE

NCY

(LBS

02/

WIR

E HP

-HR)

NORTON

KENICS

PENTECH

FMC TUBE

SANITAIRE

BAUER

ENVIREX

FMC CB

Whittier Narrows Clean Water

Page 8: Redmon_Energy Savings Through Improved Aeration Efficiency

LA COUNTY PROCESS WATER TESTING

Fine Bubble Grid

Fine Bubble Tubes

Jet Aeration

The winner was the FINE BUBBLE GRID.Ceramic Disc Diffusers became the equipment of

choice for Los Angeles County.

RECENT HISTORY

Page 9: Redmon_Energy Savings Through Improved Aeration Efficiency

WHITTIER NARROWS – FINE BUBBLE

Page 10: Redmon_Energy Savings Through Improved Aeration Efficiency

WHITTIER NARROWS - JETS

Page 11: Redmon_Energy Savings Through Improved Aeration Efficiency

RECENT HISTORY

Norton & Sanitaire introduced ceramic grid aeration systems in U.S. in late 1970’s & early 1980’s Main problems were related to diffuser fouling

Parkson Corporation introduced flexible tube diffusers in early 1980’s.

Early problems with plasticized PVC

Later switched to polyurethane

Changed the marketplace

Page 12: Redmon_Energy Savings Through Improved Aeration Efficiency

RECENT HISTORY

Mid 1980’s thru 1990’s numerous vendors introduced membrane diffusers.

Parkson, Sanitaire, EDI, Envirex, EIMCO, Wilfley Weber

Membrane formulations evolved

By late 1990’s membranes were taking over the fine bubble

market

The switch to membranes was driven by fouling issues related to

porous media diffusers.

Page 13: Redmon_Energy Savings Through Improved Aeration Efficiency

RECENT TRENDS IN AERATION

Away from mechanical & coarse bubble systems

Toward fine bubble full-floor coverage systems

General movement away from porous (ceramic) media fine bubble systems

Movement toward fine bubble membrane diffuser systems

Movement toward higher density fine bubble layouts for increased energy efficiency

Page 14: Redmon_Energy Savings Through Improved Aeration Efficiency

BENEFITS OF HIGH DENSITY LAYOUTS

High density layouts operate at lower diffuser fluxes As the diffuser flux (airflow / unit area) is decreased

bubble size decreases.

High density layouts reduce density gradients As diffuser density is increased vertical liquid

velocities are decreased

Page 15: Redmon_Energy Savings Through Improved Aeration Efficiency

EFFECT OF BUBBLE SIZE

The smaller the bubbles the larger the A / V ratio.

The smaller the bubbles the slower the bubble rise rate.

Smaller bubbles have greater surface area and longer residence time in the liquid, both of which increase the clean water oxygen transfer.

Page 16: Redmon_Energy Savings Through Improved Aeration Efficiency

AREA/VOLUME RATIO VS BUBBLE SIZE

0

2040

60

80100

120

140160

180

0 1 2 3 4 5 6 7 8 9 10 11

BUBBLE DIAMETER (MM)

AR

EA/V

OLU

ME

RA

TIO

A / V RATIO VS BUBBLE SIZE

Page 17: Redmon_Energy Savings Through Improved Aeration Efficiency

FINE BUBBLE GRID –SOTE VS DIFFUSER FLUX AND DENSITY

FINE BUBBLE GRID - 15.O FT SWDSOTE VS DIFFUSER FLUX

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0

DIFFUSER FLUX (SCFM/FT2)

SO

TE

(D

EC

IMA

L)

24.6 DIFFUSER DENSITY

16.7% DIFFUSER DENSITY

12.55% DIFFUSER DENSITY

9.85% DIFFUSER DENSITY

6.55% DIFFUSER DENSITY

4.90% DIFFUSER DENSITY

4.10% DIFFUSER DENSITY

Page 18: Redmon_Energy Savings Through Improved Aeration Efficiency

SOTE AS A FUNCTION OF DIFFUSER DENSITY

SOTE VS DIFFUSER DENSITYAT 1.0 SCFM

24

26

28

30

32

34

36

0 5 10 15 20 25 30

DENSITY (%)

SOTE

2.44 SCFM/FT21.22 SCFM/FT24.88 SCFM/FT2

Page 19: Redmon_Energy Savings Through Improved Aeration Efficiency

THE IMPACT OF DIFFUSER DENSITY ON WATER CIRCULATION AND BUBBLE RISE VELOCITY

LOW DENSITY – HIGH CIRCULATION VELOCITY

& SHORT BUBBLE RETENTION TIME

HIGH DENSITY – LOW CIRCULATION VELOCITY

& LONG BUBBLE RETENTION TIME

Page 20: Redmon_Energy Savings Through Improved Aeration Efficiency

STATE OF THE ART – HIGH DENSITY FINE BUBBLE SYSTEMS

Initially available from two suppliers in U.S.

Parkson Corporation

Aero Strip Corporation

Other suppliers now in the market place

OTT Group

ITT / Sanitaire

EDI

SSI

Page 21: Redmon_Energy Savings Through Improved Aeration Efficiency

POLYURETHANE STRIP DIFFUSERS

Characteristics:

Polyurethane Membrane Media

Micro-perforations

Diffuser Densities up to 70 – 80%

Similar performance

Page 22: Redmon_Energy Savings Through Improved Aeration Efficiency

POLYURETHANE MEMBRANE

High strength polyurethane

Precision cut perforations

UV inhibitor

Page 23: Redmon_Energy Savings Through Improved Aeration Efficiency

SANITAIRE STRIP DIFFUSERS - GOLD SERIES

Page 24: Redmon_Energy Savings Through Improved Aeration Efficiency

AERO STRIP DIFFUSERS – RICHLAND, WA

Page 25: Redmon_Energy Savings Through Improved Aeration Efficiency

AERO STRIP DIFFUSERS AT RICHLAND, WA –OFFGAS TESTING

Page 26: Redmon_Energy Savings Through Improved Aeration Efficiency

Parkson HiOx Ultra-Fine Bubble Diffusers

Page 27: Redmon_Energy Savings Through Improved Aeration Efficiency

Next

Page 28: Redmon_Energy Savings Through Improved Aeration Efficiency

OTT TUBES IN HIGH DENSITY CONFIGURATION

Page 29: Redmon_Energy Savings Through Improved Aeration Efficiency

OTT TUBES IN A HIGH DENSITY CONFIGURATION

Page 30: Redmon_Energy Savings Through Improved Aeration Efficiency

ENERGY ESTIMATES FOR VARIOUS AERATORS

ALPHA -SAE CLEAN HIGH SRT SAE PROCESS

AERATOR TYPE WATER SYSTEMS DO CONC WATER AVE. SAE lbs O2/hp-hr mg/l lbs O2/hp-hr lbs O2/hp-hr

High Speed Surface 1.5 - 2.3 0.85 2 1.0 - 1.5 1.25Low Speed Surface 2.5 - 3.5 0.85 2 1.65 - 2.3 2Disc Aerator Surface 1.8 - 2.8 0.85 2 1.2 - 1.85 1.5Turbine 2.0 - 3.0 0.75 2 1.2 - 1.8 1.5Coarse Bubble Roll 2.2 - 3.2 0.65 2 1.15 - 1.65 1.4Coarse Bubble Grid 2.7 - 3.7 0.65 2 1.4 - 1.9 1.65Aspirator No Blower 0.8 - 1.2 0.6 2 0.4 - 0.6 0.5Aspirator With Blower 1.2 - 1.9 0.6 2 0.55 - 0.9 0.75Fine Bubble Grid Standard 5.7 - 8.0 0.6 2 2.75 - 3.9 3.3Fine Bubble Grid Hi Density 7.0 - 12.0 0.6 2 3.4 - 5.8 4.6

Page 31: Redmon_Energy Savings Through Improved Aeration Efficiency

FUTURE TRENDS – LARGE PLANTS

AS ENERGY COSTS RISE THESE PLANTS WILL MOVE TOWARD HIGH DENSITY SYSTEMS

PLANTS WILL MOVE TOWARD MORE SOPHISTICATED DO CONTROL SYSTEMS

PLANTS WILL MOVE TOWARD THE NEWER MORE ENERGY EFFICIENT BLOWERS

Page 32: Redmon_Energy Savings Through Improved Aeration Efficiency

STANDARD DENSITY VERSUS HIGH DENSITY

COMPARING AN 8% DENSITY SYSTEM VERSUS A 35% DENSITY SYSTEM

BOD 200; N 35; LOADING 30 #/d/kcf; SRT 15 days

At 8 cents/kwh payback is 5.6 years

At 10 cents/kwh payback is 4.5 years

At 12 cents/kwh payback is 3.8 years.

Page 33: Redmon_Energy Savings Through Improved Aeration Efficiency

FUTURE TREND – SMALL PLANTS

Convert from surface aeration (disc aerators, slow speed surface units, and aspirators) to fine bubble grids and mixers.

This trend has already started. Several oxidation ditch systems have converted to fine bubble diffusers with mixers to propel the fluid around the loop.

Energy reductions are in the order of 30 to 50%.