Upload
industrial-doors
View
222
Download
0
Embed Size (px)
Citation preview
8/8/2019 Radar Motion Detector for Automatic Doors
1/4
EN_Radar_OCM20_v2-3.docx
Movem
a
The OCM20 microwavedetector controls the openinggates and automatic doors.installed at a height ranging fmetres and guarantees the sof an area from 3 to 30 squar
The device will be autactivated by moving pevehicles within the controlled
OCM20 has been developed(to detect movement either iby movement in both direcgenerated through a DopplerA LED on the front panel indarea.
Power supply voltageCurrent supplyOperating frequencyOutput Power (EIRP)Range detectionDuration of relay inputInsulation classInstallation heightDetectable speedRelay contactVertical adjustmentHorizontal adjustmentOperating temperatureDimensions/weight
OVia Mongilardi 3Tel. [email protected]
nt detector rada
tomatic doors
ovementof factoryIt can beom 3 to 6rveillancemetres .
omaticallysons orerimeter.
sing planar technology, and can be set iforward or backward direction) or bi-di
ions). A microprocessor processes thffect and sends an OK to the opening c
icates that movement has taken place i
TECHNICAL DETAILS
12 24 V AC /12 - 3050 mA max.9,90 GHz
14 dBm1 10 m settable1 6 s settableIP 666 m max.0,1 m/s min.1A - 24 VAC/DC0 60-45 +45-20 +50 C160 x 95 x 110 mm /
M Industrial Doors- 13900 - BIELLA - ITALY01 - Fax +39.015.8492660
om - www.ocmflex.com
r for
n mono-directionalrectional (activatede signals received-mmand.nside the controlled
DC
500 g
8/8/2019 Radar Motion Detector for Automatic Doors
2/4
8/8/2019 Radar Motion Detector for Automatic Doors
3/4
EN_Radar_OCM20_v2-3.docx
A
The LED on the detector fronfor all the time the relay is acti
Fig. 1
Wire colour DeRed 12-
Black 12-Green COBrown ConBlue ConTab. 1
OCM20 has a relay with switcAccording to the setting of ththe combinations described inThese conditions are valid wh
The trimmer TR2 on the lowdesired duration of the electri
OVia Mongilardi 3Tel. [email protected]
BBFE
panel (Fig. 2-B) will indicate the detectvated.
Fig. 2
cription4 V AC/DC
4 V AC/DCcontact relaytact NO (without power supply)tact NC (without power supply)
RELAY CONTACT SETTING
hing contact.dip-switch 3 (Fig. 1-B) in the lower se
table 2 can be obtained.en the device is powered.
r section of the detector (Fig. 1-E) cacontact, which can vary from 0.5 6 se
M Industrial Doors- 13900 - BIELLA - ITALY01 - Fax +39.015.8492660
om - www.ocmflex.com
ion of a movement,
tion of the detector,
be used to set theonds.
8/8/2019 Radar Motion Detector for Automatic Doors
4/4
EN_Radar_OCM20_v2-3.docx
DSW3 ON(Normal mode)
DSW3 OFF(Safety mode)
Tab. 2
D
It is possible to define the cothe position of dip-switch 4 (Fdetector (Fig. 1-F), the regudesired area.
Fig. 3
OVia Mongilardi 3Tel. [email protected]
BROWN BLUENC
C
NO
GREEN
NOBROWN
GREENC
BLUENC
ETECTION RANGE SETTINGS
trolled area by changing the inclinationig. 3). With trimmer TR1, located on thelation can be optimised to activate de
BS (incl. 60)
AS (incl. 45)
Dimensions i
M Industrial Doors- 13900 - BIELLA - ITALY01 - Fax +39.015.8492660
om - www.ocmflex.com
NOBROWN
GREENC
BLUENC
BROWN BLUENC
C
NO
GREEN
of the detector andlower section of thetection only for the
AS : High sensitivity
BS : Low sensitivity
meters