27
Laboratory Space Redesign AMC Lab Redesign Team Mayo Conference on Quality

Quality Conference Presentation 9-30-09

Embed Size (px)

Citation preview

Page 1: Quality Conference Presentation 9-30-09

Laboratory Space RedesignLaboratory Space Redesign

AMC Lab Redesign Team

Mayo Conference on Quality

AMC Lab Redesign Team

Mayo Conference on Quality

Page 2: Quality Conference Presentation 9-30-09

Our TeamOur Team

• Ann Tompkins – Lab

• Tim Schneider – Facilities

• Aaron DeVries – Finance

• Theresa Horvei – Lab

• Peggy Drennan – Clinic Nursing

• Justin Bushaw – Network Services

• Justin Sherman – PI

• Ann Tompkins – Lab

• Tim Schneider – Facilities

• Aaron DeVries – Finance

• Theresa Horvei – Lab

• Peggy Drennan – Clinic Nursing

• Justin Bushaw – Network Services

• Justin Sherman – PI

Page 3: Quality Conference Presentation 9-30-09

Project CharterProject Charter

• Purpose:• The purpose of this project is to reduce the turn

around time from order request to reported results.• This was within our control

• The current layout segmented lab into pods, reducing efficiency

• Benefits:• Quicker diagnosis and treatment for patients• Increase patient, physician, and staff satisfaction• Staff retention

• AMC Strategic Plan Alignment:• Improve quality, safety, service while decreasing

costs.• Create value by meeting or exceeding patient

requirements

• Purpose:• The purpose of this project is to reduce the turn

around time from order request to reported results.• This was within our control

• The current layout segmented lab into pods, reducing efficiency

• Benefits:• Quicker diagnosis and treatment for patients• Increase patient, physician, and staff satisfaction• Staff retention

• AMC Strategic Plan Alignment:• Improve quality, safety, service while decreasing

costs.• Create value by meeting or exceeding patient

requirements

Page 4: Quality Conference Presentation 9-30-09

What Did We KnowWhat Did We Know

• Current lab design has each area (chemistry, hematology, serology, microbiology, blood bank and urinalysis) in a “pod” of its own.

• The location of the low volume test pods are closer to the specimen processing area, while highest volume tests are located further away

• Current lab design has each area (chemistry, hematology, serology, microbiology, blood bank and urinalysis) in a “pod” of its own.

• The location of the low volume test pods are closer to the specimen processing area, while highest volume tests are located further away

Page 5: Quality Conference Presentation 9-30-09

What Did We KnowWhat Did We Know• Workforce Shortage

• CLS professionals are desperately needed in the healthcare industry workforce.

• 46% of laboratories report taking 3-12 months to fill a vacancy

• Median age = 48 years • ~25% of workforce (73,000 ) will retire in

next 10 years. • Only 2 laboratorians enter the field for

every 7 that retire.

• Workforce Shortage• CLS professionals are desperately needed

in the healthcare industry workforce. • 46% of laboratories report taking 3-12

months to fill a vacancy • Median age = 48 years • ~25% of workforce (73,000 ) will retire in

next 10 years. • Only 2 laboratorians enter the field for

every 7 that retire.

Page 6: Quality Conference Presentation 9-30-09

What Did We KnowWhat Did We Know• Workforce Shortage

• In 2005, the National Accrediting Agency for Clinical Laboratory Science (NAACLS) summarized:

• Graduates needed/yr = 13,700• Actual graduates/yr = 4,445 • Yearly shortfall ~ 9,200

• Shortage will also come at the same time baby boomers retire and require more health care

• Workforce Shortage• In 2005, the National Accrediting

Agency for Clinical Laboratory Science (NAACLS) summarized:

• Graduates needed/yr = 13,700• Actual graduates/yr = 4,445 • Yearly shortfall ~ 9,200

• Shortage will also come at the same time baby boomers retire and require more health care

Page 7: Quality Conference Presentation 9-30-09

Desired OutcomesDesired Outcomes• This project is designed to create a

more efficient work space by:• Reduce motion within the laboratory

• Lower turn around time• Freeing staff to handle higher

volumes• Improve the staff morale

• Staff are overburdened • Reduce time spent on non patient care

related work• Primarily inventory

• This project is designed to create a more efficient work space by:

• Reduce motion within the laboratory • Lower turn around time• Freeing staff to handle higher

volumes• Improve the staff morale

• Staff are overburdened • Reduce time spent on non patient care

related work• Primarily inventory

Page 8: Quality Conference Presentation 9-30-09

The Lab Before The Lab Before

Page 9: Quality Conference Presentation 9-30-09

What Did We Know What Did We Know • August 2008:

• 430 chemistry samples per day• Key devices were not situated in proximity:

• Specimen drop off• Processing• Centrifuge• Chemistry analyzer• PC for resulting

• Resulted in staff spending a large portion of time criss-crossing lab

• August 2008:• 430 chemistry samples per day• Key devices were not situated in proximity:

• Specimen drop off• Processing• Centrifuge• Chemistry analyzer• PC for resulting

• Resulted in staff spending a large portion of time criss-crossing lab

* Only used a 5 day work week, no weekends

Page 10: Quality Conference Presentation 9-30-09

Tools UsedTools Used

•Gantt Chart

•Staff Surveying

•Spaghetti Diagrams

•Time Studies

•Project Budget

Page 11: Quality Conference Presentation 9-30-09

Gantt ChartGantt Chart

Page 12: Quality Conference Presentation 9-30-09

Employee SurveyingEmployee Surveying

No more

“Strongly Disagrees”

General shift to more positive responses on all questions!

Page 13: Quality Conference Presentation 9-30-09

Spaghetti Diagram August 2008Spaghetti Diagram August 2008

Specimen Drop Off (start of process)

Chemistry Analyzer

Processing / Centrifuge

PC

Specimen Storage (end of process)

Page 14: Quality Conference Presentation 9-30-09

Spaghetti Diagram June 2009Spaghetti Diagram June 2009

Specimen Drop Off (start of process)

Chemistry Analyzer

Chemistry Processing / Centrifuge PC

Specimen Storage Drawer (end of process)

Tube Station

Page 15: Quality Conference Presentation 9-30-09

Spaghetti Diagram September 2009Spaghetti Diagram September 2009

Specimen Drop Off (start of process)

Chemistry Analyzer

Processing / Centrifuge

PC

Specimen Storage Drawer (end of process)

Page 16: Quality Conference Presentation 9-30-09

Inventory SystemInventory System• Par Excellence:

• Average AMC Lab on hand inventory:• $67,675.43

• Previous 7 months average

• Hours per week inventorying = 6 hours • $10,124/yr at $32.45/hr; .15 FTE

• Par Excellence savings examples:• St. Anthony's, St. Petersburg, FL (12%)• Mayo Clinic, Jacksonville, FL (21%)

• Par Excellence:• Average AMC Lab on hand inventory:

• $67,675.43• Previous 7 months average

• Hours per week inventorying = 6 hours • $10,124/yr at $32.45/hr; .15 FTE

• Par Excellence savings examples:• St. Anthony's, St. Petersburg, FL (12%)• Mayo Clinic, Jacksonville, FL (21%)

Page 17: Quality Conference Presentation 9-30-09

Projected Soft & Hard Dollar SavingsProjected Soft & Hard Dollar Savings• Soft Dollar Savings:

• Motion reduction = $22,360 (chemistry)• Motion reduction = $6,931 (rest of lab)

• Using a 31% reduction

• Hard Dollar Savings• Inventory reduction = $11,166 (Par Ex)

• Average of $8,121.05 & $14,211.84 (low & high estimates)

• Inventory labor hours = $10,124 (.15 FTE)

• Total Annual Savings = $50,581

• Soft Dollar Savings:• Motion reduction = $22,360 (chemistry)• Motion reduction = $6,931 (rest of lab)

• Using a 31% reduction

• Hard Dollar Savings• Inventory reduction = $11,166 (Par Ex)

• Average of $8,121.05 & $14,211.84 (low & high estimates)

• Inventory labor hours = $10,124 (.15 FTE)

• Total Annual Savings = $50,581

Page 18: Quality Conference Presentation 9-30-09

Project BudgetProject Budget

Expense TypeOriginalEstimate

Total Cost

Over (Under)Budget

Par Excellence $14,820 $12,313 $ (2,507)

Carts $38,624 $39,539 $ 915

Electrical/Data Upgrades $15,000 $11,348 $ (3,652)

Venting and Duct Work $ 2,000 $ 1,778 $ (222)

Wall Removal $ 6,500 $ 956 $ (5,544)

Plumbing/CO2 $ 2,000 $11,429 $ 9,429

Hazardous waste cabinet $ 1,200 $ 1,068 $ (132)

Misc. $ - $ - $ -

Totals $80,144 $78,430 $ (1,714)

Page 19: Quality Conference Presentation 9-30-09

ChallengesChallenges

• Scope creep• Unexpected data needs arose

• Concurrent pharmacy project• New data closet

• Facilities staff had many demands• Chapel project• End of 2008 spending

• AMC had surplus to spend, resulting in added work for facilities staff

• Contracted some work out

• Scope creep• Unexpected data needs arose

• Concurrent pharmacy project• New data closet

• Facilities staff had many demands• Chapel project• End of 2008 spending

• AMC had surplus to spend, resulting in added work for facilities staff

• Contracted some work out

Page 20: Quality Conference Presentation 9-30-09

Project Outcomes Project Outcomes • Successes:

• June 2009 design reduced motion on our highest volume tests by 65.2%

• Reduction in motion will allow us to better meet future capacity increases

• Potential to run up to 700 chemistry tests per day with existing staffing

• September 2009 changes resulted in further motion reduction of 28.4% from the June 2009 design

• Successes:• June 2009 design reduced motion on our

highest volume tests by 65.2%• Reduction in motion will allow us to better

meet future capacity increases • Potential to run up to 700 chemistry tests

per day with existing staffing• September 2009 changes resulted in further

motion reduction of 28.4% from the June 2009 design

Page 21: Quality Conference Presentation 9-30-09

Our New LabOur New Lab•Consolidated 2 sinks into 1 area

•2 processes into one area

•Millipore (filtering)

•Molecular cleaning

Page 22: Quality Conference Presentation 9-30-09

Our New LabOur New Lab

•Processing more open, June 2009 (top)

•New core lab (left)

Page 23: Quality Conference Presentation 9-30-09

Our New LabOur New Lab

• Low volume tests done outside of core lab (top)

•Processing motion reduced (left)

Page 24: Quality Conference Presentation 9-30-09

Our New LabOur New Lab

• Processing area located next to centrifuge and in front of tube system (not pictured) (left)

•Specimen drop off clearly identified (right)

•Core lab ‘opened’ Sept 2009

Page 25: Quality Conference Presentation 9-30-09

Lessons LearnedLessons Learned

• Site visits were beneficial:• St. Mary’s (OK to keep changing)• Mayo Florida (Cart design)• Eau Claire (Process on going)

• Communication with staff crucial• Gantt Chart• Surveying • Department Meetings

• Site visits were beneficial:• St. Mary’s (OK to keep changing)• Mayo Florida (Cart design)• Eau Claire (Process on going)

• Communication with staff crucial• Gantt Chart• Surveying • Department Meetings

Page 26: Quality Conference Presentation 9-30-09

Lessons LearnedLessons Learned

• Having key players at the table from the start was crucial, however we noticed two shortfalls:• IT should have been at table from start• Did not have bench techs at all team

meetings from start

• Detailed plan allowed administration to support the team moving forward

• Having key players at the table from the start was crucial, however we noticed two shortfalls:• IT should have been at table from start• Did not have bench techs at all team

meetings from start

• Detailed plan allowed administration to support the team moving forward

Page 27: Quality Conference Presentation 9-30-09

Questions?Questions?