Qualification of Duct Resonator Array for Noise Reduction in Offshore Installations Sandra Rodiño Palacios – Statoil ASA

Qualification of Duct Resonator Array for Noise Reduction in Offshore Installations

  • Upload
    justus

  • View
    69

  • Download
    0

Embed Size (px)

DESCRIPTION

Qualification of Duct Resonator Array for Noise Reduction in Offshore Installations. Sandra Rodiño Palacios – Statoil ASA. Noise in Offshore Installations. Poor quality of speech & radio communication. Hearing Damage. Reduced quality of restitution & rest. - PowerPoint PPT Presentation

Citation preview

Page 1: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

Qualification of Duct Resonator Array for Noise Reduction in Offshore Installations

Sandra Rodiño Palacios – Statoil ASA

Page 2: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

2

Noise in Offshore Installations

Excessive noise can compromise worker’s Health and Safety

Hearing DamagePoor quality of speech & radio communication

Reduced quality of restitution & rest

Reduced ability to perceive warnings through PA system

Page 3: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

3

Our context on the Norwegian Continental Shelf

High focus to reduce noise exposure

Use of technical barriers, attenuate sound emissions from the source

Target turbo-machinery, a major contributor to total noise exposure

Provide our projects with flexible and efficient solutions, in terms of sound attenuation, space usage, maintenance, life-cycle, etc.

Page 4: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

4

History of D-R Array in Statoil

Statoil learns the array can be applied as a spool piece so-called pipe array. Advantages: no compressor disassembling or internal modification, attenuation irrespective of size/type of compressor

4

2000

After2007

2011

Development of D-R™ duct resonator array by Dresser-Rand, a centrifugal compressor noise reduction device

2002 Statoil qualifies D-R array for use inside compressors; satisfactorily implemented since

2012 Pipe array is qualified and been recommended for use

A new qualification process starts; laboratory acoustic measurements are made

Page 5: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

5 2013-01-25

Pipe Array Design

Typically delivered with a 4-diameter effective length

Array liner

One-piece solid steel tube with acoustic chambers connected to the flow path by a series of perforations

Inserted on a spool piece and applied to the inlet/discharge pipe

Page 6: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

6 2013-01-25

Based on Helmholtz’s resonance theory, air resonance in a cavity

At the resonance frequency, ƒ0, energy loss occurs due to friction and viscosity

The insert of the array changes the impedance of the pipe wall from acoustically rigid to absorptive

How it works

)(20

lLPcf

Soun

d at

tenu

atio

n (d

B)

Page 7: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

7 2013-01-25

Pipe Array Frequency Response Perforations are designed and tuned to reduce the noise at

the Blade Passing Frequency of the compressor

According to manufacturer the overall noise attenuation is 10dBA (or 90% sound power reduction), 4-D length

BPF

1st HarmonicExample of compressor tonal noise spectrum with (solid) and without (dotted) pipe array of 8-diameter length

Page 8: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

8 2013-01-25

Qualification Process

Evaluate the technology performancei.e. identify operational consequences and manage risk

Verify the acoustic performance

Investigate further its characteristics and

possibilities for implementation

Laboratory acoustic measurements

Accommodate practical conditions in offshore installations

Page 9: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

9 2013-01-25

Acoustic Measurements Sound insertion loss (dB) = difference in sound pressure level measured before and after the resonator

Sound analyzer

Custom madeloudspeaker

Inlet pipe

L=4*D

Discharge pipe

L =4*D

Microphone holes w/ rubber gasket

Inner diameter=12,5mm

Short circuit tube L = 4*D

Sound absorber tubeL=4*D

Flange pipeL=10*D

Broadband noise source

Page 10: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

10 2013-01-25

Results – Verification of Attenuation

Upstream = signal before arrayDownstream = signal after array

Sound attenuation ~14-18dB (4D) at BPF range (2-3kHz)

At least 7-8 dB overall attenuation (82-85% sound power reduction) – average in octave bands –

Page 11: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

11 2013-01-25

Correlation between effective length and insertion loss Effect of applying spool pipe in-series or with 90° bend Effect of dividing a 4D pipe array into 2 spool, 2D each

Study of Various Array Configurations

array1 array 2

0D

2D

4D

6D

8D

0° 90°

2x2D

Active area of array

Page 12: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

12 2013-01-25

Approximately linear correlation between effective area of array and resulting sound attenuation

The arrays are tuned in the longitudinal direction!

Results – Flexible Length

Active area of array

Page 13: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

13 2013-01-25

Results – Flexible Setup

13

Performance is not diminished by angle of separation between pipes allows significant flexibility of configuration

Pipe array is most effective when placed as close to the source as possible!

Page 14: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

14 2013-01-25

Mechanical and Process Assessment

Design and manufacturing of PDRA reviewed and approved by Statoil piping and material technology specialists

Gas flow measurements done by DR confirm no pressure drop cause by the presence of the PDRA

Documented positive effect on pipe vibration Means to avoid liquid accumulation:

16% of lower circumference not perforated Drain capability

No negative impact including corrosion or liquid accumulation of PDRAs in operation reported from other DR customers

Page 15: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

15 2013-01-25

Conclusion & Way Forward

Significant reduction of the noise level at design frequency Potential flexibility of implementation which can facilitate its

use in projects with challenging layouts Compliance with our goals by qualifying and recommending

PDRA technology to efficiently reduce noise exposure Positive collaboration between manufacturers and industry to

find best fit of technical solutions to installation demands Identified potential for other uses in machinery/applications

with distinctive tonal components, e.g. HPU

Page 16: Qualification of Duct  Resonator  Array  for  Noise Reduction  in Offshore Installations

16

Qualification of Duct Resonator Array for Noise Reduction in Offshore Installations

Sandra Rodiño PalaciosEngineer Health&WE - Acoustics E-mail address [email protected]: +4746803478

www.statoil.com

Thank you!

Questions?

Thanks to:

&