Q&E Plumbing

POCKET INSTALLATION GUIDE

www.uponor-qe.com

Page 2: Qe pocket installation guide 2015

2 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5

Making Q&E connections withQ&E expansion tools

Note: All standard Uponor expander heads are compatible with the M12 and M18 tools.

Uponor expander heads will not auto-rotate on the Milwaukee tools (only Milwaukee expansion

heads will auto-rotate on the M12 and M18). Milwaukee heads are not compatible with Uponor

tools. Milwaukee heads are easily distinguished by color coding and the Milwaukee logo.

1. Square cut the PEX pipe perpendicular to the length of the pipe. Remove all excess material or burrs that might affect the fi tting connection.

2. Slide the Q&E ring over the end of the pipe until it reaches the stop edge. If using a Q&E ring without a stop edge, extend the ring over the end of the piping no more than 1⁄16” (1mm).

3. Milwaukee Q&E expansion tools come with built-in auto rotation. If using a Uponor Milwaukee expansion head, simply hold the pipe and tool in place while holding the trigger to expand the pipe. The head will automatically rotate to ensure the pipe is evenly expanded.

1

2

Important! When making a Q&E connection, be sure to follow the guidelines for the tool you are using in your application.

Note: Do not force the pipe onto the expander head. Ensure the expander head is rotating during each expansion.

Note: The required number of expansions can vary with ambient temperature. Uponor recommends making a test connection fi rst to gauge the pipe’s reaction time.

Note: Only Milwaukee tool auto rotates.

3

Page 3: Qe pocket installation guide 2015

3w w w. u p o n o r - q e . c o m

5

Shoulder Shoulder Shoulder

4

Description M12 Milwaukee M18 Milwaukee1057166 - 16-25mm 1063908 - 16-32mm M12 M18

12mm 16mm 1057172 1057172 4 420mm 1057173 1057173 6 625mm 1057175 1057175 9 932mm 1057177 1057177 14 1440mm 1057183 - 10

Expansions

4. Continue expanding until the pipe and ring are snug against the shoulder on the expander head. See table below for the recommended number of expansions for each pipe size.

Important! Rotating the tool between expansions will provide smooth, even expansion of the pipe. Failure to rotate the tool will cause deep grooves in the piping, which can result in potential leak paths.

5. After the fi nal expansion, immediately remove the tool and insert the fi tting. Ensure the pipe and ring seat against the shoulder of the fi tting.

Important! Only perform the necessary number of expansions. DO NOT over expand the pipe. You should feel some resistance as the fi tting goes into the pipe.

If you do not feel any resistance, the pipe may be over expanded and will require additional time to shrink over the fi tting.

Page 4: Qe pocket installation guide 2015

4 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5

Making Q&E connections withQ&E 110V REMS expansion tool

1. Square cut the PEX pipe perpendicular to the length of the pipe. Remove all excess material or burrs that might affect the fi tting connection.

2. Slide the Q&E ring over the end of the pipe until it reaches the stop edge. Extend the ring over the end of the pipe no more than 4⁄16” (4mm).

3. Slide the expander head into the pipe until it stops. Full expansions are necessary to make a proper connection.

4. Press the trigger to expand the pipe.

1

3

2

4

Page 5: Qe pocket installation guide 2015

5w w w. u p o n o r - q e . c o m

5. Release the trigger, remove the head from the pipe, rotate it 1⁄8” (3mm) turn and slide the head back into the pipe. Continue expanding and rotating until the pipe and ring are snug against the shoulder on the expander head.

6. After the final expansion, immediately remove the tool and insert the fitting. Ensure the pipe and ring seat against the shoulder of the fitting.

5

6

Q&E tee inserted into Uponor PEX pipe Brass fitting inserted into Uponor PEX pipe

Description 110V REMS Expansions1084551 - No heads included

40mm 1004035 850mm 1004036 563mm 1004038 5

Page 6: Qe pocket installation guide 2015

6 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5

Cold weather expansionsTemperatures affect the time required for the piping and ring to shrink onto the fitting.

1. Warming the Q&E fittings and Q&E Rings reduces contraction time.

Put fittings and rings in your pockets prior to installation to keep them warm.

2. Make Q&E connections at temperatures above -15°C (5°F).

3. Fewer expansions are necessary in temperatures below 4.4°C (40°F).

4. Perform a test connection for each pipe size when temperatures differ from day to

day, keeping note of number of expansions to make a snug fitting connection.

Distance between fittingsMinium distance between Q&E fittings

Pipe sizeCut length

of pipe

65mm

80mm

110mm

130mm

140mm

160mm

16mm

20mm

25mm

32mm

40mm

50mm160mm63mm

Cut length of pipe

Troubleshooting Q&E connections1. Ensure the Q&E expander tool is properly maintained and in good working condition.

2. Make sure the expander head is securely tightened onto the tool.

3. Frequently check that the expander head is securely tightened to tool.

4. Ensure the segment fingers are not bent.

5. Remove excess grease.

6. Check the fitting for damage. Nicks and gouges will cause the fitting to leak.

7. Make sure the last expansion is not held in the expanded position before inserting the fitting.

8. If using a manual (hand) expander or REMS tool, rotate the head 1/8“ (3mm) turn after each expansion.

Page 7: Qe pocket installation guide 2015

7w w w. u p o n o r - q e . c o m

Operating temperature and pressures

Application Workingtemperature

Max. operating temp.

Max.working pressures

Heating systems 80°C 95°C1

Hot water services 70°C 95°C2

Cold water services 20°C 20°C

6 bar

6 bar

12bar

Diameter (mm)Straight lengths

hot pipe, horizontal (m)

Straight lengthscold pipe,

horizontal (m)

Coilshot pipe,

horizontal (m)

0.4 0.75

0.5 0.8

0.6 0.85

0.4

0.4

0.5

0.85 0.85 0.75

0.85 0.85 0.75

0.85 0.85 0.75

1.0 1.0 1.0

Minimum bend radius for Uponor Q&E pipe

Q&E plumbing system is suitable for recirculating/secondary hot water systems.

Dimenions Min. bend radius

65mm

80mm

110mm

130mm

140mm

160mm

16mm

20mm

25mm

32mm

40mm

50mm

160mm63mm

16mm

20mm

25mm

32mm

40mm

50mm

63mm

Radius

Page 8: Qe pocket installation guide 2015

8 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5

Connections to other systems

Power tool maintenance

Keep your tool, battery pack and charger in good repair by adopting a regular maintenance program.

Each month:• Remove the expander head and soak in degreasing agent to remove grease from between

expander segments• Wipe expander cone with clean, dry, lint-free cloth

Re-lubricate:After six months to one year, depending on use, return the tool, battery pack and charger to a Milwaukee service facility for:• Lubrication• Mechanical inspection and cleaning (gears, spindles, bearings, housing, etc.)• Electrical inspection (battery pack, charger, motor)• Testing to assure proper mechanical and electrical operationIf the tool does not start or operate at full power with a fully charged battery pack, clean the contactson the battery pack. If the tool still does not work properly, return the tool, charger and battery pack,to a Milwaukee or REMS service facility for repairs.

Cleaning:Clean dust and debris from charger and tool vents. Keep tool handles clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean the tool, battery pack and charger since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include gasoline, turpentine, lacquer thinner, paint thinner, chlorinated cleaning solvents, ammonia and household detergents containing ammonia. Never use flammable or combustible solvents around tools.

Repairs:For repairs, return the tool, battery pack and charger to the nearest service centre.

The comprehensive range of fittings for Uponor PEX pipe allows adaption to many other plumbing systems and components.

Please refer to the table below

Copper

SolderSolder first and allow to cool before

making the Q&E joint

Compression Use with compression fitting bodies conforming to EN 1254

Valves

Thread Seal with PTFE tape

CompressionCompatibility of threads must

be checked

Plastic Thread Seal with PTFE tape

Old UponorPEX pipe

15, 22 & 28mm

CompressionUse with compression fitting bodies

conforming to EN 1254

Uponor item NotesMethodSystem toconnect to

Page 9: Qe pocket installation guide 2015

9w w w. u p o n o r - q e . c o m

PPSU threaded fitting instructionsMaterial

Polyphenylsulfone Radel R 5100Use PTFE tape according to EN751-3 FRp

Tape thickness:0,076 - 0,1 mm for 1/2” threads0,1 - 0,2 mm for 3/4” - 1 threads

Threaded fittings Swivel nut

• Start to add PTFE tape from the bottom of the thread. Move up leaving first thread free.

• Add tape clockwise to allowgood sealing performancebetween the threads.

• It will be easier for threads to get a good start when having firstthreads on male fitting free.

• Ensure that gasket is in place.

• Do not use sealing tape on male counter threads.

• Fingertip tighten, and ...

... tighten with suitable wrench 90O

.

The following products are recommended with Q&E PPSU products

PTFE tapes according to EN 751-3 FRp

Loctite 5061, Loctite 5331, Loctite 516

� The following products are strictly forbidden with Q&E PPSU products

Ever Seal Thread 483Loctite 55, Loctite 518, Loctite 542, Scotch-Grip Rubber 1300, Scotch- Grip Rubber 2141Scotch-Grip Rubber 847, Rector Seal 5Rite-Lock, Selet Unyte

Special notes for pressure testing Q&E joints

Uponor Q&E joints depend on the elasticity of the Uponor PEX material to form a tight joint. At low temperatures, the elasticity ofthe material is reduced. This means a longer period of time for the joint to become tight. The pipe will always shrink back to it’s original dimensions and the joint will always eventually become leak tight.

Please observe the minimum waiting timeafter making the last joint before making the system pressure test. The joint can be pressure tested after 30 mins at ambient temperatures above 5OC. At lower temperatures allow more time before testing the joints, as shown in the table below.

The maximum test pressure for Uponor PEX pipe with Uponor Q&E joints which must not be exceeded is 18 bar.

Time to pressure testing with Q&E joints

5°C above 0.5 hour

0°C to +5°C

1.5 hours

3 hours-5°C to 0°C

-10°C to -5°C

4 hours

Ambient Temperature Time to pressure test

Page 10: Qe pocket installation guide 2015

1 0 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5

Expansion compensating devices

Calculation of a flexible arm and expansion loop

The flexible arm should be long enough to prevent damage, and support clamps should be placedsufficiently far from the wall to allow for longitudinal thermal expansion.

Use the formula below to calculate the minimum length of the arm.

When designing an expansion loop it is preferable to design it so that I

2= 0.5I

1. In case the flexible

arm is calculated according to the equation below:

Example:An Uponor PE-Xa pipe with an outside diameter (OD) of 50mmis installed with 30m between anchor points. The hot water it carries is 70OC and the ambient temperature is 20OC. Calculatethe length (LB) of the flexible arm.

Calculate the thermal length variation by using the diagram.

No special expansion compensatorsare needed if:•The water pipe is supported and anchored at a maximum spacing of 6m.•The water pipe is run in a conduit where the necessary space for expansion is provided in the gap between water pipe and conduit.•The pipe is run in long lengths on a rack.

However, in installations allowing the thermal expansion, where the pipes are expected to stay straight, expansion campensators should be used.

From the graph, the thermal expansionat 20OC is 2.5mm/m, while the expansionat 70OC is 12.5mm/m.

The expansion of the pipe will be12.5-2.5 = 10mm/m when carryingwater at 70OC. The total thermal lengthvariation in this case is:∆L - 10mm/m x 30m = 300mm.

Page 11: Qe pocket installation guide 2015

1 1w w w. u p o n o r - q e . c o m

Gas

Uponor PEX pipes must not be used to carry gas inside a building or to carry compressed air.

Corrosion inhibitors

Corrosion inhibitors should be used in central heating systems in the normal way to prevent corrosion of steel radiators and other components. Uponor PEX pipes are not affected by proprietary anti-corrosion compounds such as Fernox or Sentinel at the normal recommended dosing levels.

Anti-freeze

Ethylene glycol central heating anti-freeze mixtures have no adverse effect on Uponor PEX pipes.

Where systems are left with residual water in unheated and unprotected buildings in freezing conditions, there is a risk of frost damage to the pipe. In all cases where there is a risk of freezing, add a glycol-based antifreeze to the water to avoid ice damage to the pipe. The % mixture should be in accordance with the particular brand of anti-freeze being used and the expected temperature level.

After freezing conditions have lifted and before the system is started, the anti-freeze mixture should be fully flushed out of the loops and disposed of properly in accordance with local regulations.

Painting

Uponor PEX pipe is specially manufactured in white to obviate the need for onsite painting. It is not recommended to paint Uponor PEX pipe.

Other considerations

Pressure testing

Hydraulic pressure testing shall be undertaken in accordance with BS EN 806-4:2010 or Water Regulations 1999 using cold potable water BEFORE the system is taken into operation. Hydraulic pressure testing is not a substitute for the correct installation of the PEX pipe and associated fittings. It is essential that the correct size fittings are used for the pipe and that thermal movements are taken into account when installing the pipe.

The test pressure applied to the system should be 10 bar or 1.5 x the maximum pressure rating of

the lowest rated component in the system. The maximum test pressure applied to Uponor Q&E pipe should not exceed 18 bar at 20°C. Other equipment in the system, such as boilers, cylinders, radiators, valves, etc. should be checked with the manufacturer as to their maximum pressure rating BEFORE any pressure test of the complete system is performed. If in any doubt, isolate all other equipment before pressure testing and only test the Uponor PEX pipe with the Uponor Q&E joint or Uponor compression fittings.

Air testing is acceptable.

Method

• Vent and fill the system with water.

• Visually inspect the whole system for leaks.

• Pressurise the installation to a test pressure of not less than 1.5 times the maximum working pressure.

• Apply the test pressure by pumping for a period of 30 minutes. Inspect for leaks.

• Reduce the pressure in the pipework by bleeding water from the system to 0.5 times the maximum working pressure.

• Close the bleed valve. Visually check for leakage and monitor for 90 minutes. If there is no reduction in pressure the system is regarded as leak tight.

• Flush the system as required.1.5

1.0

0.5

003 0 60 90 120

Pressure testing graph

Page 12: Qe pocket installation guide 2015

1 2 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5

Uponor Q&E storing and handling guidelinesRefer to the Uponor Q&E plumbing installation guide for a comprehensive list of guidelines.

• Do not store PEX piping outdoors.

• Do not use Uponor piping where temperatures and pressures exceed limits.

• Do not weld, glue or use adhesives or adhesive tape with Uponor piping.

• Do not apply open flame to Uponor piping.

• Do not install Uponor piping for any gas appliances.

• Do not install Uponor piping within 12" of any recessed light fixture unless the piping is protected with suitable insulation or the light is Insulation Contact (I.C.) rated.

• Do not install Uponor piping within 5 ft. of direct view from fluorescent lighting without sleeving the pipe with UV-blocking material.

• Do not solder, braze, weld or fusion-weld within 18" of any Uponor piping in the same water line. Make any heat-related connections prior to making the Q&E connection.

• Do not spray on or allow organic chemicals, strong acids or strong bases to come into contact with Uponor piping.

• Do not use petroleum or solvent-based paints, greases or sealants on Uponor piping.

• Do not use Uponor piping for an electrical ground.

• Do not press Q&E brass fittings (i.e., copper press).

Note: When transitioning from PEX to other piping materials, follow the appropriate installation instructions for that product.

• Do keep PEX piping in the original packaging until time of installation.

Page 13: Qe pocket installation guide 2015

1 3w w w. u p o n o r - q e . c o m

Simple, Secure & Complete.Adaptable, High Flowing & Hardwearing.

For more information visit www.uponor-qe.com

PLUMBING SYSTEM

SPEND £500 on Q&E Shrink-Fit

and claim your free gift

SPEND £500 on Q&E Shrink-Fit

and claim your free gift

Simple, Secure & Complete.

worth

£650

Receive the Expansion Tool and choose from the Impact Driver,

Pipe Cutter or a Heated Jacket when you spend £500 (excluding VAT).

Visit http://www.uponor-qe.com/qe-tool-deals

for more details and to claim your free gift.

FREEMILWAUKEE EXPANDER

MILWAUKEE GIFT

&

Simple, Secure & Complete.

Pipe Cutter or a Heated Jacket when you spend £500

http://www.uponor-qe.com/qe-tool-deals

for more details and to claim your free gift.

for more details and to claim your free gift.

http://www.uponor-qe.com/qe-tool-deals

for more details and to claim your free gift.

for more details and to claim your free gift.

Simple, Secure & Complete.Simple, Secure & Complete.

Receive the Expansion Tool and choose from the Impact Driver,

Pipe Cutter or a Heated Jacket when you spend £500 (excluding VAT).

Simple, Secure & Complete.Simple, Secure & Complete.

Page 14: Qe pocket installation guide 2015

1 4 C o n t a c t u s o n 0 1 4 5 5 5 5 0 3 5 5 1 4

Join the conversation...

@UponorUK

UponorUK

Uponor UK

For more information and training courses available, visit;

www.uponor.co.ukwww.uponor-qe.com

or call us on

01455 550 355

Design and Estimating

[email protected]

Page 15: Qe pocket installation guide 2015

A vital phase that includes fi nal approval of the construction work, and lays the foundations for effi cient operation and maintenance.

At the commissioning stage, we support our partners in verifying the desired performance of our systems. Full and accurate fi nal system documentation is always made available to the client. Our training enables building management professionals to ensure smooth and trouble-free operation. We offer support on our system's use, optimisation and eventual refurbishment – not just today and tomorrow but through the whole life cycle of a building.

At the end of construction, the utilisation of a building begins

Support TeamUponor’s professional support team can offer practical and technical advice to any query, providing remote and on-site customer support.

Direct Contact:T 0844 8000 171E [email protected]

1 5

Page 16: Qe pocket installation guide 2015

Copyright © Uponor (Uponor Limited.)

Reproduction of any part of this publication for any purpose is not

permitted without the prior written permission of Uponor Limited.

The contents of this brochure are provided for guideline only, please

consult our technical manuals for full up-to-date information.

Uponor reserves the right to alter specifi cations and operating

parameters for all their Underfl oor Heating and Plumbing & Heating

Systems at any time as part of its policy of continuous product

development.

Care has been taken to ensure that the information in this price guide

is correct at the time of going to press. Uponor Limited reserve the

right to alter prices and the details of designs and performance of

products without notice. E&OE.

Uponor Limited (“Uponor”) guarantees [to the original purchaser/

customer] that pipes and fittings sold by it are free of defects in

materials or manufacture under normal conditions of use for a period

of 25 years and in case of electrical and mechanical products for

2 years from the date of installation. This guarantee only applies to the

products stored, installed, tested and operated in accordance with the

fitting instructions issued by Uponor and valid at the time the products

were installed.

Where a claim is made during the guarantee period and products are

proven to be defective in materials and/or manufacture at the time of

delivery, Uponor will supply replacement products free of charge. This

is the exclusive remedy under this guarantee.

Uponor disclaims any warranty or guarantee not expressly provided

for herein, including any implied warranties of merchantability or

fitness for a particular purpose. Uponor further disclaims any and all

responsibility or liability for losses, damages and expenses, including

special, direct, indirect, incidental and consequential damages, whether

foreseeable or not, including without limitation any loss of time or use

or any inconvenience arising from the ownership, installation or use of

the products sold hereunder.

This guarantee does not affect the statutory rights of the consumer.

Uponor LimitedGilmorton RoadLutterworthLeicestershireLE17 4DU

T 01455 550355F 01455 550366E [email protected] www.uponor.co.uk

Q&

E-PG

-Aug

-201

5-U

K