Upload
phungminh
View
217
Download
2
Embed Size (px)
Citation preview
PUSH BAR 90+PUSH BAR 90+
Push Bar 90+
1 - Series Push Bar 90+The rangePoint to highlight 90 series towards 90+ series
2 – Marketing tools on a CDCE EN1125 certificate in PDF formatFire test certificate in PDF formatEnglish documentations in PDF formattechnical file in DWG formatpictures and drawings in DXF, JPEG HD and LD
:
New aestheticComplete range :
• 1 side point version• Vertical version• 3 points version, side + verticalSafety60 mm touch pad projection = maximum free
passage.Safety : Trigger bolt to block the bolt in door closed position
Dogging version with cylinder: For non- fire rated doorsEasy to fit :
• No handed • Same fixing holes than 90 Push bar• 2 hours fire rated• 240 Hours salt spray resistance
Toward the new Push Bar 90+
Push Bar 90+
NEW
Push Bar 90+Technical evolution
1 – Push Pad and support
No visible screws or fixing hole ( on the back plate ) .Silent aluminium padPad and pad support in aluminiumAdjustment cutting : till 400 mm
2 - Push Bar 90+ head
Similar for 1-2-3 points versionsSide fixing cover
Head cover and end fixing bracket cover in zamackBigger trigger bolt for easy striker plate adjustment
3 - Vertical
Epoxy coated rods coversTop and bottom latches working by pulling and with anti-picking device
4 - Fitting
Fixing dimensions unchangedCompatible with EN3000 / EN2000
5 – Finishing and accessories
3 mains epoxy finish: Silver, new silver metallic finish RAL 9022Black, and white.Dogging version for European cylinder
Striker plates support.
1
2
3
4
Push Bar 90+
For single of double leaf door for timber, metal, PVC and glass doors
Push Bar 901 point, 2 points Vertical
Push Bar 90+Push Bar 90+1 point,
2 points Vertical,
3 points, side and vertical
Outside trims
EN3000/PR2E series
+ EN2000 series
Outside trims compatibility • Exact retrofitting with 90 series.
.
Push Bar 90+
1 point
2 points
3 points
Push Bar 90+
The changes :
– The code item numbers– The design, the metallic aluminium silver finish– The cutting adjustment of push bar– The packaging, the installation notice.
The similar points with 90 series :
– EN1125 approved– Applications,– Fixing dimensions – Compatibility with Outside trims
To note :
Push Bar 90+
Push Bar 90+
packaging
THE FITTING INSTRUCTIONS
Push Bar 90+
//
1. Axe horizontal = 1 035 mm du sol fini. 1. Horizontal axis = 1035mm from finished floor.
2. Axe A (côté ouverture) 2. Axis A (on opening side)1 ou 3 points 1 or 3 points versionA1= 44 mm du bord de l’huisserie (recouvrement) A1= 44 mm from the edge of the frame.A2= 22 mm du bord de l’huisserie (affleurant) A2= 22 mm from the edge of the frame.2 points A2 bis= 45 mm 2 points version A2 bis= 45 mm
Axe B= minimum 30 mm du bord de l’huisserie. Axis B= 30mm minimum from the edge of the frame.
3. Pointer et percer: 3. Mark and drill the door:H3 pour portes standard H3 for standard doorsH3 et H4 pour portes COUPE-FEU H3 and H4 for fire-rated doorsF1 Ø 15mm avec ensemble extérieur F1 Ø 15mm with an outside trim
4. Gabarit B sur l’Axe B (côté paumelles): 4. B template on the A axis (hinge side):Pointer et percer H5. Mark and drill the door H5.
5. Relever la distance A-B ÉÉtape 2tape 2 5. Measure the distance A - B StepStep 22
Loquets haut et bas ÉÉtapes 5 et 6tapes 5 et 6 Top and bottom latch Steps 5 et 6Steps 5 et 6
1. Gabarit D1 pour portes avec recouvrement (A93). 1. D1 template for overlapping doors (A93).Gabarit D2 pour portes affleurantes. Tracer (A96). D2 template for flushed doors.
Draw (A96).Pré percer aux emplacements indiqués(H1, H2, H8, H9) Pre-drill as indicated (H1, H2, H8, H9)
2. Gabarit E (loquet bas+gâche basse A92): 2. E template (bottom latch and striker A92):Positionner le gabarit par rapport au sol fini. Tracer. Position the template to the finished floor.
Draw.Pré percer aux emplacements indiqués(H1, H2, H8, H9) Pre-drill as indicated (H1, H2, H8, H9)
3. Repère C Visser le support de cache tringle. 3. Mark C Screw the rod cover retainers clips.
JPM PUSH BAR 90+FERMETURES ANTI-PANIQUE EN APPLIQUE 1/2/3 POINTS RIM PANIC EXIT DEVICE 1/2/3POINTS
N01-154 Ind. C
2
CONTENU DE LA BOITE / CONTENT OF THE PACKAGE
1 PREPARATION DE LA PORTE DOOR PREPARATION
MISE A LONGUEUR DE L’ANTI-PANIQUE / ADJUSTMENT OF THE PANIC EXIT DEVICEPartie active de la barre = 60% minimum de la largeur effective de la porte.For the active regulation, it is compulsory that the active bar covers at least 60% of the door width.
M4x15Recoupe : AB+ 4 mm A1, A2, A2bisA1, A2, A2bisÉviter la disqueuse ou meuleuse. Utiliser 1 boîte à onglet pour faciliter la coupe de la barre.Coupe à l’équerre et ébavurée. Évacuer la limaille.
Cut : AB + 4 mm A1, A2, A2bisA1, A2, A2bisAvoid the grinding machine. Use a mitre box to facilitate the cut of the bar. Cross to the square and deburred. Evacuate the filings.
1 point: barre, capots, sachet visserie, gâches. 1 point: bar, covers, screw set, strikers.
2/3 points: barre, capots, sachet visserie, gâches, tringles, cache-tringles, loquets. 2/3 points: bar, covers, screw set, strikers, rods, rod covers, top and bottom latches.Les caractéristiques de sécurité de ce produit sont essentielles pour satisfaire à l'EN1125. Aucune modification d'aucune sorte, autre que celles décrites dans ces instructions, n'est permise. L’utilisation de ce produit certifié est limitée à une porte dont les caractéristiques n’excèdent pas : - Hauteur maximale 2 300mm- Largeur maximale 1 300mm- Poids de la porte : maximum 200 kg.The characteristics of security are essential to satisfy to EN1125 requirements. No modification, except the ones described in the present instructions are allowed. The use of this certified product is limited to one door which characteristics do not exceed:-Maximum height 2300 mm- Maximum width 1300 mm- Maximum weight of the door 200 kg.
0
M4x15
A
Distance AB + 4 mm
40 Route de ParisAVERMES
F 03000 MOULINS08
3 7 6 1 1 4 2 2 B0333 CPD40 - 250033EN1125: 1997 / A1 : 2001
H5/H6
H9
H4
H3
H3
H4
M3x6
Auto taraudeuse
Thread cutting screws
N01-154 Ind. C
5
3 POSE DU FOUILLOT / INSTALLATION OF THE FOLLOWER
4 INSTALLATION DE LA BARRE / FIXING OF THE BAR
POSE DU LOQUET HAUT + GÂCHE HAUTE / INSTALLATION OF THE TOP LATCH + STRIKER
6IMPORTANT : Dans la cadre d’un remplacement de produit, les gâches et loquets sont à changer.WARNING: In case of a push bar 90 replacement, strikers and latches must be changed.
POSE DU LOQUET BAS + GÂCHE BASSE / INSTALLATION OF THE BOTTOM LATCH + STRIKER
Cas d’utilisation avec série EN3000/EN2000/PR2E.Only in case of a use with an outside trim EN3000/EN2000/PR2E.
H9
H8
H2/H1
H8
H2/H1
Vérifier le bon fonctionnement de la Push Bar 90+.
Check if the Push Bar 90+works correctly.
Sol fini / Finished floor
Porte Coupe-feuFire rated door
Portes standardStandard doors
H8/H9 M5x35 CZ Ø 4,2x32H1/H2 M4x35 CZ Ø 4,2x32
Porte Coupe-feuFire rated door
Portes standardStandard doors
H3 M6x30 Ø 5,5x32H4 M6x30
H5/H6 M6x30 Ø 5,5x32F1F2
Ø 15Ø 30
Ø 15Ø 30
Gâche / Striker H1/H2 M4x35 Ø 3,5x16Gabarit / Template Gâche / Striker
A1 A98A2 A99
A2 bis A99Double vantail / Double leaf
Anti-paniquePanic Exit Device
Porte / DoorRecouvrement / OverlappedAffleurant / Flushed
IMPORTANT : Dans la cadre d’un remplacement de produit, les gâches et loquets sont à changer.WARNING: In case of a push bar 90 replacement, strikers and latches must be changed.
Gâches hautes/ Top strikersA93 A96
D1 D2Vérifier les positions: gâche + loquet.Check positions: striker + latch.
E
N01-154 Ind. C
7 POSE DE LA TRINGLERIE / INSTALLATION OF THE RODS
8 IMPORTANT : Dans la cadre d’un remplacement de produit, les cache-tringles sont à changer.WARNING: In case of a Push Bar 90 replacement, rod covers must be changed.
POSE DES CACHE-TRINGLES + CAPOTS / INSTALLATION OF THE ROD COVERS + CASE COVERS
Coupe Cut
Tiges hautes /Top rod
L= X-10mm
Tiges basses /Bottom rod
L= Y-10mm
Loquet haut/ bas Top/bottom latches
IMPORTANT : Dans la cadre d’un remplacement de produit, les tringles sont à changer.WARNING: In case of a Push Bar 90 replacement, rods must be changed.
Haut L=X
Top L=X
Bas L=Y
Bottom L=Y
Vis auto taraudeusesThread cutting screws
IMPORTANT :Vérifier le bon fonctionnement de la Push Bar 90 +.
WARNING :Check if the Push Bar 90+ works correctly.
H M6
M3x6
M4x15
M3x8
M4x6
3.9x16
2 points haut et bas: zoom
2 points top and bottom: zoom
Fixation + contrôle de fonctionnementFixing + check if it works correctly
3 points latéral, haut et bas
3 points lateral, top and bottom
3.9x16
M3x6
maximum
maximum
9 ENTRETIEN / MAINTENANCEIMPORTANT : graissage des gâches toutes les 20000 manoeuvres. WARNING : grease the strikes after 20000 openings.
renouveler l’opération tous les ans. repeat this operation each year.
N01-154 Ind. C
Y
X
10 VUE D’ENSEMBLE / GENERAL VIEW
H5/H6
M3x6
M4x15M3x8
M4x6
3.9x16
3.9x16
M3x6
H3
H4
H9
H8
H9
H8
Vis auto taraudeusesThread cutting screws
I DOOR CARACTERISTICS IHeight : 2300 mm.
width 1200 mm.
Weight : 200kg.
Touch Bar Type B
Adjustable on site
Active pad length 775mm or 1080mm adjustable till 400 mm
.
Fixing center distance 90 mm (45 mm from the follower)
Spindle Cross type ( only for outside trim use )
Material
Touch pad and support : epoxy coated.
Rod covers and top an bottom covers : steel epoxy coated .
Head cover and end bracket cover : zamack epoxy coated
Under plate : steel zinc plated
Push Bar 90+
I INSTALLATION I
CE EN 1125 approved by AFNOR Certificate CE0333 CPD40-250033
Fire rated doors
> Single leaf (1 side point, 3 points, side and vertical )
Testing door Certificate Efectis France n° 85-G7-T7
> Double leaf ( vertical )
Testing door Certificate Efectis France n° 88-U238
A98 A99
I DIMENSIONS I
Push Bar 90+
Configurations
Available on request
Over lapping door Flush door
Dimensions
Side type
A98000 A99000 A13300
PVC support
S02532-01-0A
S02532-02-0A
Push Bar 90+
I SIDE STRIKES AND SUPPORT I
Configuration
Available on request
Push Bar 90+ I SIDE STRIKES AND SUPPORT I
- Top strikeOverlapping doors (timber, steel, PVC doors)
Flush doors ( aluminium doors )
- Bottom strikeA92000
I OUTSIDE TRIMS I
> Modularity
PUSH BAR 90+ series can be combined with an outside trim EN3000 or PR2E.
Center distance : 90 mm ( 45mm from each follower side)
Single European profile cylinder 40mm (30/10) or Swiss profile on request.
Push Bar 90 +
I OPTIONS I
Dogging (non- doors only)
Activated by single European cylinder ( 40mm).
KitsGlass door kit KG9000.
Extension kit S91000 For door height > 2 300 mm Threaten rods (865 mm) and rod covers (867 mm).
with connexion and fixing device and Isophonic joint.
Door thickness 55 à 115mm KE2000
screws and cross spindle
Door selector Series 914000
Push Bar 90 +
SINGLE LEAF DOOR
DOUBLE LEAF DOOR
I ITEM CODE NUMBERS I
1 side point Standard Dogging 900 mm width door PJ1000 PJ10011200 mm width door PJ1100 PJ11012 Vertical points900 mm width door PJ2000 PJ20011200 mm width door PJ2100 PJ21013 points side and vertical900 mm width door PJ3000 PJ30011200 mm width door PJ3100 PJ3101
I FINISHES ISilver -08, black-02, white -03.
> Other epoxy coated on request, more than 100 colours ( RAL number to precise ).
Push Bar 90 +