11
1 Prototype for double read-out with PDs and WLF fibers Lorenzo Pacini, lorenzo.pacini@fi.infn.it, Herd work-shop, Xi’an, 2019/16/10

Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

1

Prototype for double read-out with PDs and WLF fibers

Lorenzo Pacini,[email protected],

Herd work-shop, Xi’an, 2019/16/10

Page 2: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

2

IntroductionThe basic idea is the design of a double read-out system for the HERD Calorimeter:

The Chinese system → WaveLengthShifter (WLS) fibers read-out with Imaging Intensifier + IsCMOS

3 fibers per crystal, one is used for the trigger, 2 are connected to the Imaging Intensifiers

The CaloCube system → photo-diodes (PDs) read-out with HIDRA chips.

2 PDs with different active areas are glued to the cube.

HIDRA (HIDRA1 and HIDRA2) is a double gain Carge Sensitive Amplifier (CSA) with automatic gain selection (see also previous presentation).

Pro: the same scintillation light is read-out with 2 independent systems.

Cons: power consumption, difficult mechanical arrangement (not discussed in this presentation).

Important check: is the fiber signal strongly affected by the presence of the PDs?

Page 3: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

3

Fiber attenuation due to PDThanks to the Chinese colleagues, we received 3 cubes wrapped with ESR film and with 3 WLSs glued to the top surface during the first months of 2019.

We connected the 3 WLSs to 3 SiPMs (AdvanSid ASD-RGB1C-P).

We use the HIDRA to read-out SiPM (see next slide).

We compare WLS signal without and with the Large PD (VTH2090), we also used some ESR to simulate different active area for the LPD.

Page 4: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

4

HIDRA for SiPM

HIDRA is a CSA which integrates for a selected amount of time.

This chip is not studied for SiPMs, thus the performance is not optimized so far.

Minimum integration window width (used for SiPM): 10 µs.

Pedestal acquisition with random trigger: a large number of events contains at least one photo-peak due to the SiPM dark counts. (~ 100KHz).

The photo-peaks acquired during the random trigger can be used to check the SiPM gain during the data-taking

Page 5: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

5

Tested configurations of LYSO + PD + WLF fibersThe configurations are named:

ESRX - Cube 1 is wrapped with ESR (WLS only)

PDX - VTH2090 is attached to Cube 1 (WLS+LPD), so that the equivalent dark area is 15x16mm2

PD5x5/PD10x10 - as before, but we cut a ESR square in order to reduce the dark area to 5x5 and 10x10 mm2

Sequence of tests:

● ESRA -> PDA -> ESRB1 -> ESRB2 -> PDB -> PD5x5 ->

● - > ESRC -> PD10x10A -> PD10x10B -> ESRD

Example of MIP signal with one configuration.The peak is estimated with a gaussain fit.

Page 6: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

6

Attenuation results (March 2019)Thanks to Eugenio BertiFiber 1

Fiber 2 Fiber 3

Relative variations with respect to the first configuration.

Green circles are acquisition with ESR used to check the stability of the system

The last acquisitions are not stable due to big variation in temperature.

Attenuation results:

Standard PD: 20.0 ± 2.5%

5mm x 5mm PD: 5 ± 2.5%

10mm x 10mm PD: the system it was not stable but the attenuation is ~ 15-10 %

A 20% attenuation seems acceptable.

Page 7: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

7

FIrst test of LYSO+PD+SiPM (May 2019)We added a PD to one LYSO which have the WLF fibers in order to test the complete system.

We used one cube to measure the S/N ratio with the large PD (VTH2090) and 2 different SiPMs:

SiPMs: Hamamatsu S12571-010, pitch 10 or 15 µm.

First test: verify the S/N with the PD and SiPMs only, common noise subtraction is needed.

Using HIDRA 1 and without coupling material between the fibers and the SiPM

Page 8: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

8

First test with HIDRA2 (June 2019) All the test discussed so far are done with HIDRA1 boards and ROC digital logic (Calocube configuration)

We started the testing of one HIDRA2 board (which includes the auto-trigger) and TROC digital logic (made by CIEMAT)

Preliminary test with PD+LYSO show very promising results.

First test of new electronics Signal with LPD+LYSO+HIDRA2+TROC

Red: events which hit the trigger

Blue events which do not hit the trigger

Pedestal MIP

Page 9: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

9

Assembly of the LYSO+Fiber in FlorenceThanks to Xin Liu and Zhigang Wang we have now all the LYSO crystals assembled with:

3 WLS fibers, only one used so far, it will be connected to a SiPM

2 PDs with different active area

All WLFs were tested using a SiPM and HIDRA2 electronics.

We have 3 completed layers so far.

Page 10: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

10

Coupling material between the fibers and the SiPMWe realized that the value of the signal strongly depend on the coupling between the WLFs and the SiPM.

The signal of the SiPM (pitch 10 µm) will be attenuated since it is very big with respect to the PD.

We are investigating the use of teflon (~ 500 µm) between the SiPM and the fibers:

Seems that using the teflon we are able to get consistent results among different measurements (checked using a LED to inject ligth inisde the WLS) and a MIP signal which is attenuated with respect the case without the teflon.

Preliminary results with HIDRA2

Preliminary results with HIDRA2

Page 11: Prototype for double read-out with PDs and WLF fibers · 5 Tested configurations of LYSO + PD + WLF fibers The configurations are named: ESRX - Cube 1 is wrapped with ESR (WLS only)

11

ConclusionThe assembly of the prototype is almost completed .

It consists in 4 layers, the first one contains only 1 LYSO crystals in the center, the other 3 layers contains a 3x3 matrix of LYSO

The SiPM will be used to read out the light of one fibers per cristyals.

Both PD and SiPM will be read-out with HIDRA2

With our prototype the expected dynamic range for a single LYSO cube is (to be tested):

Large PD saturation ~ 1800 MIP ~ 54 GeV, [S/N(MIP) ~ 7]

Small PD saturation ~ 50 * LPD ~ 2.5 TeV

SiPM 10 µm ~ 340 MIP ~ 10 GeV. [S/N(MIP) ~ 5]

We obtained time for a beam test @LNF-BTF (Frascati, Italy) but unfortunately the accelerator have major problem now thus we are searching for different solutions to test our prototype (linearity, saturation correlation between PD and SiPM…).