Protection and switchgear

Prepared by R.Karthi kn

Page 2: Protection and switchgear Prepared by R.Karthi kn

1. Identify the inductive elementa)Transistor b)Transformer c)diode d)none of these

Page 3: Protection and switchgear Prepared by R.Karthi kn

2. Identify the protective devicea)CB b)Relay c)both A & B d)none of these

Page 4: Protection and switchgear Prepared by R.Karthi kn

3. Identify the element that subjected to more faults

a )motor b) busbar c)diode d) Transformer

Page 5: Protection and switchgear Prepared by R.Karthi kn

4. In protective apparatus CT is connected toa)CBb)Relayc)PTd)none of these

Page 6: Protection and switchgear Prepared by R.Karthi kn

5. In protective apparatus trip coil in overcurrent relay is connected to

a)CBb)Relayc)PTd)CT

Page 7: Protection and switchgear Prepared by R.Karthi kn

6. In induction disc type which currents will be formed

a) forward currentb) Reverse currentc) eddy currentd) Saturation current

Page 8: Protection and switchgear Prepared by R.Karthi kn

7. Other name of induction disc type relay isa) shaded pole relayd) Permanent magnet relayc) mho relayd)none of these

Page 9: Protection and switchgear Prepared by R.Karthi kn

8. Other name of admittance relay isa) shaded pole relayd) Permanent magnet relayc) mho relayd)Watt hour meter relay

Page 10: Protection and switchgear Prepared by R.Karthi kn

9. In induction cup type relay will be formeda) high torqueb) high currentc) low torqued)low current

Page 11: Protection and switchgear Prepared by R.Karthi kn

10.In relay is mandatorya)High impedanceb)low impedancec)zero impedanced)very high impedance

Page 12: Protection and switchgear Prepared by R.Karthi kn

11. Relay contacts are normally made up of:a) Silver contactsb) Copper contactsc) Aluminium contactsd) Lead contacts

Page 13: Protection and switchgear Prepared by R.Karthi kn

12. Sparking between the contacts can be reduced by inserting:a) A capacitor in parallel with the contactsb) A capacitor in series with the contactsc) A resistor in the lined) A reactor in the line

Page 14: Protection and switchgear Prepared by R.Karthi kn

13. The contact resistance is least affected by:a) Shape of the contact facesb) Ambient temperaturec) Mechanical forces appliedd) Amount of surface commutation

Page 15: Protection and switchgear Prepared by R.Karthi kn

14. The arc voltage produced in an ac circuit breaker is always:a) In phase with the arc currentb) Lagging the arc current by 90 degc) Leading the arc current by 90 degd) In phase opposition with the arc current

Page 16: Protection and switchgear Prepared by R.Karthi kn

15. Breaking capacity of the circuit breaker is usually expressed in:a) MVAb) MWc) Kilo-amperesd) kV

Page 17: Protection and switchgear Prepared by R.Karthi kn

16. Which of the following circuit breakers produce least arc energy:a) Plain oilb) Minimum oilc) Air blastd) Air break

Page 18: Protection and switchgear Prepared by R.Karthi kn

17. A thermal protection switch is used to provide protection against:a) Over loadb) Temperaturec) Short circuitd) Over voltage

Page 19: Protection and switchgear Prepared by R.Karthi kn

18. In a circuit breaker the current which exists at the instant of contact separation is known as

(A) re striking current(B) surge current(C) breaking current(D) recovery current.

Page 20: Protection and switchgear Prepared by R.Karthi kn

19. Sulphur hexafluoride is a(A) Conductor of electricity(B) Semi-conductor(C) Inactive gas(D) Dielectric.

Page 21: Protection and switchgear Prepared by R.Karthi kn

20. As the force on contact is increased, the contact resistance will

(A) increase linearly(B) increase exponentially(C) remain unaltered(D) decrease.

Page 22: Protection and switchgear Prepared by R.Karthi kn

21. The arcing contacts in a circuit breaker are made of

a)copper tungsten alloyb)Silver alloyc)lead d)aluminium

Page 23: Protection and switchgear Prepared by R.Karthi kn

22.On which of the following routine test conducted

a)relayb)CBc)fused)CT

Page 24: Protection and switchgear Prepared by R.Karthi kn

23. In overcurrent relay , plug setting ranges

from 50 % toa)150b)200c)300d)500

Page 25: Protection and switchgear Prepared by R.Karthi kn

24. In overcurrent relay , plug setting range is determined by

a)15 stepsb)35 stepsc)25 stepsd)none of these

Page 26: Protection and switchgear Prepared by R.Karthi kn

25.The main function of a fuse is to(a) protect the line(b) open the circuit(c) protect the appliance(d) prevent excessive current

Page 27: Protection and switchgear Prepared by R.Karthi kn

26.The upper magnet in induction type overcurrent relay is shaped

a)Tb)Uc)Ed)none of these

Page 28: Protection and switchgear Prepared by R.Karthi kn

27.EIDMT meansa) Extra inverse current definite minimum time b) Enormous inverse current definite minimum time c) Extremely inverse current definite minimum time d) Efficient inverse current definite minimum time

Page 29: Protection and switchgear Prepared by R.Karthi kn

28 Overload relays are of…… type.(a) induction(b) solid state(c) thermal(d) electromagnetic(e) all above

Page 30: Protection and switchgear Prepared by R.Karthi kn

29. Magnetic circuit breaker has ______ trip action.(a) delayed(b) instantaneous(c) both of the above(d) none of the above

Page 31: Protection and switchgear Prepared by R.Karthi kn

30. In order that current should flow without causing excessive heating or voltage drop, the relay contacts should(a) have low contact resistance(b) be clean and smooth(c) be of sufficient size and proper shape(d) have all above properties

Page 32: Protection and switchgear Prepared by R.Karthi kn

31. Circuit breakers usually operate under(a) transient state of short-circuit current(b) sub-transient state of short-circuit current(c) steady state of short-circuit current(d) after D.C. component has ceased

Page 33: Protection and switchgear Prepared by R.Karthi kn

32. Directional relays are based on flow of(a) power(b) current(c) voltage wave(d) all of the above

Page 34: Protection and switchgear Prepared by R.Karthi kn

33. A differential relay measures the vector difference between(a) two currents(b) two voltages(c) two or more similar electrical quantities(d) none of the above

Page 35: Protection and switchgear Prepared by R.Karthi kn

34. When a transmission line is energized, the wave that propagates on it is(a) current wave only(b) voltage wave only(c) both (a) and (b)(d) power factor wave only

Page 36: Protection and switchgear Prepared by R.Karthi kn

35. The voltage appearing across the contacts after opening of the circuit breaker is called______voltage.(a) recovery(b) surge(c) operating(d) arc(e) none of the above

Page 37: Protection and switchgear Prepared by R.Karthi kn

36. Ionization in circuit breaker is facilitated by(a) high temperature(b) increase of mean free path(c) increasing field strength(d) all of the above

Page 38: Protection and switchgear Prepared by R.Karthi kn

37. In a circuit breaker the basic problem is to

(a) maintain the arc(b) extinguish the arc(c) transmit large power(d) emit the ionizing electrons

Page 39: Protection and switchgear Prepared by R.Karthi kn

38. Shunt capacitance is neglected while considering(a) short transmission line(b) medium transmission line(c) long transmission line(d) medium and long transmission lines

Page 40: Protection and switchgear Prepared by R.Karthi kn

39. The interaction between a transmission line and communication line is minimized by(a) transposing transmission as well as communication lines(b) increasing the height of the trans-mission line tower(c) increasing the distance between the two lines(d) all of the above

Page 41: Protection and switchgear Prepared by R.Karthi kn

40. Which of the following statements is incorrect ?(a) Lightning arrestors are used before the switchgear(b) Shunt reactors are used as compensation reactors(c) The peak short current is (1.8 xV2) times the A.C. component(d) The MVA at fault is equal to base MVA divided by per unit equivalent fault reactance