Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
ADRIAN HILL DEVELOPMENTS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
JOB NUMBER - 5536
NOTES:* IMAGES ARE DIAGRAMATIC ONLY
* REFER TO ELEVATIONS FOR DETAILS
PROPOSED DWELLINGS FOR
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
2 22
queensland inc.association of
building designers
H 280115
DESCRIPTIONREV. DATE
PRELIMINARY PLANS ISSUEDA 090514
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans), TOBE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.
WIND SPEED AS NOMINATED ON BRACING PLAN.
PROVIDE LIFT OFF HINGES TO W.C OR OPEN OUT DOOR OR MIN 1200mm CLEARANCEFROM DOOR TO PAN.
EXHAUST FANS FROM SANITARY COMPARTMENTS TO BE DUCTED TO THE OUTSIDE
ARE AIR OR TO A VENTED ROOF SPACE AND AS PER AS 1668.2
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGUALTIONS,STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACUAL OBLIGATIONS.
ALL CONSTRUCTION MATERIALS SUPPLIED MUST TAKE INTO ACCOUNT PROXIMITY TOCOASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCE WITH MANUFACTURERS
SPECIFICATIONS
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THEAUTHOR.
ADRIAN HILL DEVELOPMENTSNUMBER 16
ANDREA AVENUEBROADBEACH WATERS
JOB NUMBER - 5536
GENERAL NOTES
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,
SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERINGMATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
CONFORM TO THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIANSTANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS,
REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF
AUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATIONAS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDINGAS 1684 - 2010 NATIONAL TIMBER FRAMING CODEAS 2049 - 2002 ROOF TILESAS 2050 - 2002 INSTALLATION OF ROOF TILESAS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTIONAS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGSAS 3600 - 2000 CONCRETE STRUCTURESAS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITESAS 3700 - 2001 MASONRY IN BUILDINGSAS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGSAS 3786 - 1993 SMOKE ALARMSAS 4055 - 2006 WIND LOADINGS FOR HOUSINGAS 4100 - 1998 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVIL
ENGINEERING COMPUTIONS AND DRAWINGS.
SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE
WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOXINDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR
ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASEiii) FULLY GLAZED DOORS
iv) SHOWER SCREENSv) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
WITH MANUFACTURER, FLASHING ALL ROUND.
ALL GUTTERS TO BE STRAMIT QUEENSLANDER QUAD GUTTERING WITH MIN. 100x75RECTANGULAR OR 100 dia. DOWNPIPES, EACH DOWNPIPE SHALL SERVICE A MAXIMUM
ROOF AREA OF 36 sq.m OR SHALL BE POSITIONED AS PER AS 3500.3, 2003, SECTION 3.
STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BY
THE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVERTHEFLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF
PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL
CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT IS
RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITYOF BUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BE
IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF
THE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL ANDWITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sq
FOR INTERNAL WALLS BELOW BEARER.
THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5 BATTS AND REFLECTIVE FOIL
TO EXTERNAL WALLS OR AS PER ENERGY RATING.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.
BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND IN
ACCORDANCE WITH BCA 3.9.2FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE
CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLEDEFLECTION) OF THE BCA..
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF
EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
LEGEND
CJ CONSTRUCTION JOINTDP DOWNPIPEFP FIRE PLACEFW FLOOR WASTEHWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBESD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS
SITE NOTES
ALL STORMWATER AND DRAINAGE TO BE IN COMPLIANCE WITH BCAPARTS 3.1.2 & 3.5.2 AS WELL AS AS/NZS 3500.
ENSURE 90mm DIAMETER AGRICULTURAL DRAINS ARE PROVIDED TO
THE BASE OF ALL CUTS AND RETAINING WALLS AND ARE CONNECTEDTO THE STORMWATER SYSTEM VIA SILT PIT/S TO THE RBS
REQUIREMENTS.
THE EXTERNAL FINISHED SURFACE SURROUNDING THE BUILDING
MUST BE DRAINED TO MOVE SURFACE WATER AWAY FROM THEBUILDING AND GRADE TO PROVIDE A SLOPE NOT LESS THAN 50mm
OVER THE FIRST 1000mm FROM THE BUILDING.
A MINIMUM HEIGHT OF 150mm SHALL BE MAINTAINED BETWEEN THE
TOP OF THE OVERFLOW GULLY RISER & THE LOWEST FIXTURECONNECTED TO THE DRAIN. THE OVERFLOW GULLY RISER SHALL BE
LOCATED AT 75mm ABOVE SURROUNDING GROUND LEVEL OR SHALLBE FINISHED AT A HEIGHT TO PREVENT THE INGRESS OF WATER
WHEN LOCATED IN A PATH OR PAVED AREA.
CONNECT DOWNPIPES TO LEGAL POINT OF DISCHARGE VIA 100mm
DIAMETER UPVC STORMWATER PIPE LAID WITH A MINIMUM FALL OF1:100, DISCHARGE TO THE SATISFACTION OF THE RELEVANT
AUTHORITY.
ALL STORMWATER DRAINAGE BELOW GROUND SHALL BE SEWERGRADE WITH NO JOINTS UNDER SLAB INSTALLED TO AS3500.3, 2003.
MINIMUM PIPE SIZE 100mmMINIMUM GRADE 1:100
ALL POOL FENCING SHALL BE MIN. 1200mm HIGH AND INACCORDANCEWITH AS 1926.1
PROPOSED DWELLINGS FOR
RH
LAYOUT AMENDMENTS TO BOTH VILLASB 130514RH
MINOR AMENDS TO VILLA A + ALL ELEVATIONS ADDEDC 260514RH
WORKING DRAWINGS ISSUEDD 030714ST
MINOR AMENDS TO WORKING DRAWINGSE 080714ST
AMENDS TO WORKING DRAWINGS (STRUCTURE, SURVEY, GL, FL)F 160914ST
CHANGES TO WORKING DRAWINGS (ROOM & ROOF DECK)G 230115ST
AMENDS TO WORKING DRAWINGS (ROOF DECK HANDRAIL)H 280115ST
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
3 22
queensland inc.association of
building designers
H 280115
REPORT STATUS DATE
WORKPLACE HEALTH & SAFETY REPORTCOMPLETED - DISCUSSED WITH & PROVIDED TOCLIENT ALONG WITH WORKING DRAWINGS 020714
ADRIAN HILL DEVELOPMENTSNUMBER 16
ANDREA AVENUEBROADBEACH WATERS
JOB NUMBER - 5536
b) SLIPPERY OR UNEVEN SURFACES
FLOOR FINISHES
Specified finishes have been selected to minimise the risk of floors and
paved areas becoming slippery when wet or when walked on with wet
shoes/feet. Any changes to the specified finish should be made in
consultation with the designer or, if this is not practical, surfaces with an
equivalent or better slip resistance should be chosen.
The owner is responsible for the selection of surface finishes in the
pedestrian trafficable areas of this building. Surfaces should be selected in
accordance with AS HB 197:1999 and AS/NZ 4586:2004.
STEPS, LOOSE OBJECTS AND UNEVEN SURFACES
Due to design restrictions for this building, steps and/or ramps are included
in the building which may be a hazard to workers carrying objects or
otherwise occupied. Steps should be clearly marked with both visual and
tactile warning during construction, maintenance, demolition and at all times
when the building operates as a workplace.
Building owners and occupiers should monitor the pedestrian access ways
and in particular access to areas where maintenance is routinely carried out
to ensure that surfaces have not moved or cracked so that they become
uneven and present a trip hazard. Spills, loose material, stray objects or
any other matter that may cause a slip or trip hazard should be cleaned or
removed from access ways.
Contractors should be required to maintain a tidy work site during
construction, maintenance or demolition to reduce the risk of trips and falls
in the workplace. Materials for construction or maintenance should be
stored in designated areas away from access ways and work areas.
2. FALLING OBJECTSLOOSE MATERIALS OR SMALL OBJECTS
Construction, maintenance or demolition work on or around this building is
likely to involve persons working above ground level or above floor levels.
Where this occurs one or more of the following measures should be taken
to avoid objects falling from the area where the work is being carried out
onto persons below.
1. Prevent or restrict access to areas below where the work
is being carried out.
2. Provide toeboards to scaffolding or work platforms.
3. Provide protective structure below the work area.
4. Ensure that all persons below the work area have
Personal Protective Equipment.
BUILDING COMPONENTS
During construction, renovation or demolition of this building, parts of the
structure including fabricated steelwork, heavy panels and many other
components will remain standing prior to or after supporting parts are in
place. Contractors should ensure that temporary bracing or other required
support is in place at all times when collapse which may injure persons in
the area is a possibility.
Mechanical lifting of materials and components during construction,
maintenance or demolition presents a risk of falling objects. Contractors
should ensure that appropriate lifting devices are used, that loads are
properly secured and that access to areas below the load is prevented or
restricted.
3. TRAFFIC MANAGEMENTParking of vehicles or loading/unloading of vehicles on this roadway may
cause a traffic hazard. During construction, maintenance or demolition of
this building designated parking for workers and loading areas should be
provided. Trained traffic management personnel should be responsible for
the supervision of these areas.
Construction of this building will require loading and unloading of materials
on the roadway. Deliveries should be well planned to avoid congestion of
loading areas and trained traffic management personnel should be used to
supervise loading/unloading areas.
Busy construction and demolition sites present a risk of collision where
deliveries and other traffic are moving within the site. A traffic management
plan supervised by trained traffic management personnel should be
adopted for the work site.
4. SERVICESRupture of services during excavation or other activity creates a variety of
risks including release of hazardous material. Existing services are located
on or around this site. Where known, these are identified on the plans but
the exact location and extent of services may vary from that indicated.
Services should be located using an appropriate service (such as Dial
Before You Dig), appropriate excavation practice should be used and,
where necessary, specialist contractors should be used.
(in locations with underground power)
Underground power lines are located in or around this site. All underground
power lines must be disconnected or carefully located and adequate
warning signs used prior to any construction, maintenance or demolition
commencing.
(in locations with overhead power lines )
Overhead power lines are near or on this site. These pose a risk of
electrocution if struck or approached by lifting devices or other plant and
persons working above ground level. Where there is a danger of this
occurring, power lines should be, where practical, disconnected or
relocated. Where this is not practical adequate warning in the form of bright
coloured tape or signage should be used or a protective barrier provided.
5. MANUAL TASKSComponents within this design with a mass in excess of 25kg should be
lifted by two or more workers or by mechanical lifting device. Where this is
not practical, suppliers or fabricators should be required to limit the
component mass.
All material packaging, building and maintenance components should
clearly show the total mass of packages and where practical all items
should be stored on site in a way which minimises bending before lifting.
Advice should be provided on safe lifting methods in all areas where lifting
may occur.
Construction, maintenance and demolition of this building will require the
use of portable tools and equipment. These should be fully maintained in
accordance with manufacturer’s specifications and not used where faulty or
(in the case of electrical equipment) not carrying a current electrical safety
tag. All safety guards or devices should be regularly checked and Personal
Protective Equipment should be used in accordance with manufacturer’s
specification.
6. HAZARDOUS SUBSTANCESASBESTOS
(for alterations to a building constructed prior to 1990)
This building was constructed prior to 1990 and therefore may contain
asbestos either in cladding material or in fire retardant insulation material.
The builder should check and, if necessary, take appropriate action before
demolishing, cutting, sanding, drilling or otherwise disturbing the existing
structure.
(for alterations to a building constructed prior to 1986)
This building was constructed prior to 1986 and therefore is likely to contain
asbestos either in cladding material or in fire retardant insulation material.
The builder should check and, if necessary, take appropriate action before
demolishing, cutting, sanding, drilling or otherwise disturbing the existing
structure.
POWDERED MATERIALS
Many materials used in the construction of this building can cause harm if
inhaled in powdered form. Persons working on or in the building during
construction, operational maintenance or demolition should ensure good
ventilation and wear Personal Protective Equipment including protection
against inhalation while using powdered material or when sanding, drilling,
cutting or otherwise disturbing or creating powdered material.
TREATED TIMBER
The design of this building includes provision for the inclusion of treated
timber within the structure. Dust or fumes from this material can be harmful.
Persons working on or in the building during construction, operational
maintenance or demolition should ensure good ventilation and wear
Personal Protective Equipment including protection against inhalation of
harmful material when sanding, drilling, cutting or using treated timber in
any way that may cause harmful material to be released. Do not burn
treated timber.
VOLATILE ORGANIC COMPOUNDS
Many types of glue, solvents, spray packs, paints, varnishes and some
cleaning materials and disinfectants have dangerous emissions. Areas
where these are used should be kept well ventilated while the material is
being used and for a period after installation. Personal Protective
Equipment may also be required. The manufacturer’s recommendations for
use must be carefully considered at all times.
SYNTHETIC MINERAL FIBRE
Fibreglass, rockwool, ceramic and other material used for thermal or sound
insulation may contain synthetic mineral fibre which may be harmful if
inhaled or if it comes in contact with the skin, eyes or other sensitive parts
or the body. Personal Protective Equipment including protection against
inhalation of harmful material should be used when installing, removing or
working near bulk insulation material.
TIMBER FLOORS
This building contains timber floors which have an applied finish. Areas
where finishes are applied should be kept well ventilated during sanding
and application and for a period after installation. Personal Protective
Equipment may also be required. The manufacturer’s recommendations for
use must be carefully considered at all times.
7. CONFINED SPACESEXCAVATION
Construction of this building and some maintenance on the building will
require excavation and installation of items within excavations. Where
practical, installation should be carried out using methods which do not
require workers to enter the excavation. Where this is not practical,
adequate support for the excavated area should be provided to prevent
collapse. Warning signs and barriers to prevent accidental or unauthorised
access to all excavations should be provided.
ENCLOSED SPACES
Enclosed spaces within this building may present a risk to persons entering
for construction, maintenance or any other purpose. The design
documentation calls for warning signs and barriers to unauthorised access.
These should be maintained throughout the life of the building. Where
workers are required to enter enclosed spaces, air testing equipment and
Personal Protective Equipment should be provided.
SMALL SPACES
Some small spaces within this building will require access by construction
or maintenance workers. The design documentation calls for warning signs
and barriers to unauthorised access. These should be maintained
throughout the life of the building. Where workers are required to enter
small spaces they should be scheduled so that access is for short periods.
Manual lifting and other manual activity should be restricted in small
spaces.
8. PUBLIC ACCESSPublic access to construction and demolition sites and to areas under
maintenance causes risk to workers and public. Warning signs and secure
barriers to unauthorised access should be provided. Where electrical
installations, excavations, plant or loose materials are present they should
be secured when not fully supervised.
9. OPERATIONAL USE OF BUILDINGThis building has been designed to requirements of the specific building
classification identified within the drawings. Where a change of use occurs
at a later date a further assessment of the workplace health and safety
issues should be undertaken, in accordance with the provisions of the Work
Health and Safety Act 2011 or subsequent replacement Act.
(Where the specific use of the building is not known at the time of the
completion of this report and a further assessment of the workplace health
and safety issues should be undertaken at the time of fit-out for the end-
user.)
10. OTHER HIGH RISK ACTIVITYAll electrical work should be carried out in accordance with Code of
Practice: Managing Electrical Risks at the Workplace, AS/NZ 3012 and all
licensing requirements.
All work using Plant should be carried out in accordance with Code of
Practice: Managing Risks of Plant at the Workplace.
All work should be carried out in accordance with Code of Practice:
Managing Noise and Preventing Hearing Loss at Work.
Due to the history of serious incidents it is recommended that particular
care be exercised when undertaking work involving steel construction and
concrete placement. All the above applies.
WORKPLACE HEALTH &
SAFETY REPORT
Compiled in accordace with Work Health and
Safety Act 2011.
IDENTIFIED HAZARD AREAS
1. FALLS, SLIPS, TRIPS
a) WORKING AT HEIGHTS
DURING CONSTRUCTION
Wherever possible, components for this building should be prefabricated
off-site or at ground level to minimise the risk of workers falling more than
two metres. However, construction of this building will require workers to be
working at heights where a fall in excess of two metres is possible and
injury is likely to result from such a fall. The builder should provide a
suitable barrier wherever a person is required to work in a situation where
falling more than two metres is a possibility.
DURING OPERATION OR MAINTENANCE
Cleaning and maintenance of windows, walls, roof or other components of
this building will require persons to be situated where a fall from a height in
excess of two metres is possible. Where this type of activity is required,
scaffolding, ladders or trestles should be used in accordance with relevant
codes of practice, regulations or legislation.
Cleaning and maintenance of windows, walls, roof or other components of
this building will require persons to be situated where a fall from a height in
excess of two metres is possible. Where this type of activity is required,
scaffolding, fall barriers or Personal Protective Equipment should be used in
accordance with relevant codes of practice, regulations or legislation.
Anchorage points for portable scaffold or fall arrest devices have been
included in the design for use by maintenance workers. Any persons
engaged to work on the building after completion of construction work
should be informed about the anchorage points.
PROPOSED DWELLINGS FOR
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
4 22
queensland inc.association of
building designers
H 280115
820
920
820820
820
1500
820
920
820820
820
1500
720
720
24-48 panelift door
24-0
7afg
24-3
6 bi
-fol
d do
ors
24-09afg
07-28afg07-20afg
24-09alw 24-48SD
24-0
6alw
15-3
0afg
30-24afg
15-05afg
24-09alw
24-09alw
24-09alw
24-4
8 pa
nel
if t d
oor
24-0
7afg
24-3
6 bi
-fol
d do
ors
24-09afg
07-28afg07-20afg
24-09alw 24-48SD24-0
6al
w
15-3
0afg
30-24afg
15-05afg
24-09alw
24-09alw
24-09alw
301° 22' 15" 45.097
23°
17' 0
"
4.73
5
7° 47' 40"
5.447
281° 56' 20"
44.164
0° 3' 0"
7.109
7° 47' 40"
6.314
23°
17' 0
"
6.31
4
38°
46' 2
0"
6.31
4
1 2 3 4
12
1
2
12345678
11
12
13
14
1
2
3
4
5
6
7
8
9
1 2 3 4
12
1
2
12345678
11
12
13
14
1
2
3
4
5
6
7
8
9
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
8,086
1,50
0
1,500
500
500
2,20
0
2,2369,206
6,654
8,126
8,888
11,290
8,019
6,654
8,126
9,874
12,425
2,48
9
900
900
1,10
01,
100
PROPOSED 2X TWO STOREY DETACHED DWELLINGSALL LEVELS T.B.C ON SITESITE COVERAGE - 401.26/815 = 49.23%
PROPOSED PLUNGE POOLS
WATERMETER RELOCATEDT.B.C ON SITE
villa A
villa B
METER BOX
GG
METER BOX
GG
tap
tap
tap
tap
CANAL
ANDREA AVENUE
ST
OR
MW
AT
ER
STORMWATER TO STREET
STORMWATER
STORMWATER
STORMWATER
O.M
.P
O.M
.P
O.M.P
O.M
.P
To
Wall
O.M
.P
To
Wal
l
9.72 Degree
9.72 Degree
Designated Flood Level 3.61m
1.6
SITE BENCHMARK
NAIL IN KERB
RL3.27 (AHD)
WATER METER
SL3.21
WM
ROOFWATER IL3.06
EP
P
POWER POLE
FL3.65
3.27
3.26
3.24
3.23
2.4
3.3
7
3.2
4
3.1
5
3.11
3.1
1
3.1
8
3.2
2 3.30
3.42
3.38
3.37
3.2
9
3.4
4
3.52
3.23
3.20
3.18
3.16
3.26
3.29
3.6
8
3.49 3
.49
3.5
2
3.54
3.52
3.5
3 3.2
8 2.7
0 2.2
7
2.2
6
2.3
2
2.28
2.262.23
2.2
3
2.2
7
2.27
2.2
8
1.39
1.34
1.402.0
0
1.38
1.372.2
72.6
5
3.1
4
3.50
3.5
0
3.50
3.4
9
3.41
3.5
2
3.42
3.4
8
3.5
5
3.5
2
3.35
318
316
331
330
330
330
325
332
351
354
2.22
2.2
92
492
46
337
335
3283
54
358
354
3.59
353
353
6.6
2.1
4.2
3.3
3
3.3
3
1.9
ROOFWATER IL3.12 45.098
301°22'15"
4.7
35
203°1
7'
5.447187°47'40"
44.164
281°56'20"
7.1
09
0°0
3'
6.3
15
7°4
7'4
0"
6.3
15
23°1
7'
6.3
15
38°4
6'2
0"
2.5
0
2.2
5
2.5
0
2.7
5
3.0
0
3.2
5
3.2
5
3.25
3.50
3.50
3.50
3.50
Lot 194
SINGLE STOREY
RENDERED
DWELLING
SINGLE STOREY
BRICK DWELLING
SINGLE STOREY
RENDERED
DWELLING
A N D R E A
A V E N U E
CONC
CONC
BA
CK
OF
KE
RB
BR
ICK
WA
LL
BRICK WALL
CONCRETE TILT PANEL WALL
ME
TA
LF
EN
CE
METAL FENCE
CONCRETE
RETAINING
WALL
METAL FENCE
CONCRETE TILT PANEL WALL
BRICK
GARAGE
3.25
3.25
3.5
0
3.2
5
3.0
0
2.7
5
CANAL
SITE BENCHMARK
NAIL IN KERB
RL3.27 (AHD)
WATER METER
SL3.21
WM
ROOFWATER IL3.06
EP
P
POWER POLE
FL3.65
3.27
3.26
3.24
3.23
3.1
5
3.11
3.1
1
3.1
8
3.30 3.42
3.37
3.2
9
3.4
4
3.23
3.20
3.18
3.16
3.26
3.29
3.6
8
3.54
2.2
7
2.2
6
2.3
2
2.28
2.26
2.2
3
2.2
7
2.27
1.39
1.34
1.40
1.38
1.372.2
7
3.50
3.5
0
3.50
3.4
9
3.41 3.5
2
3.42
3.4
8
3.5
2
318
316
331
330
330
330
332
354
353
353
ROOFWATER IL3.12
2.5
0
2.2
5
2.5
0
2.7
5
3.0
0
3.2
5
3.2
5
3.25
3.50
3.50
3.50
3.50
A N D R E A
A V E N U E
BA
CK
OF
KE
RB
BRICK WALL
CONCRETE TILT PANEL WALL
METAL FENCE
CONCRETE
RETAINING
WALL
METAL FENCE
CONCRETE TILT PANEL WALL
3.25
3.25
3.5
0
3.2
5
3.0
0
2.7
5
CANAL
NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd
* Meter box position T.B.C on site* All retaining walls by owner
* Discharge stormwater to TANK, where possible, all otherstormwater & overflow to kerb & channel
SITE PLAN - GOUND FLOOR
SCALE 1:200 SHEET 4 OF 22 JOB NUMBER - 5536
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500
* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **
SETBACKRELAXATIONS
REQUIRED
................................
................................
................................
................................
scrapeCUT
scrape
F.L
FILL
3.250G.L
appr
ox.
3.350
................................
................................
................................
................................
scrapeCUT
scrape
F.L
FILL
3.500G.L
appr
ox.
4.000
CARPORT ONLY MAIN BUILDING
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
5 22
queensland inc.association of
building designers
H 280115
820
920
820820
820
1500
820
920
820820
820
1500
720
720
24-48 panelift door
24-0
7afg
24-3
6 bi
-fol
d do
ors
24-09afg
07-28afg07-20afg
24-09alw 24-48SD
24-0
6alw
15-3
0afg
30-24afg
15-05afg
24-09alw
24-09alw
24-09alw
24-4
8 pa
nelif
t doo
r
24-0
7afg
24-3
6 bi
-fol
d do
ors
24-09afg
07-28afg07-20afg
24-09alw 24-48SD24-0
6alw
15-3
0afg
30-24afg
15-05afg
24-09alw
24-09alw
24-09alw
1 2 3 4
12
1
2
12345678
DWPROV
DW
PR
OV
11
12
13
14
1
2
3
4
5
6
7
8
9
1 2 3 4
12
1
2
12345678
W.M
.P
RO
V
DWPROV
DW
PR
OV
11
12
13
14
1
2
3
4
5
6
7
8
9
DR
YP
RO
V
W.M
.P
RO
VD
RY
PR
OV
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
RE
F.
W.O
.W
.O.
D.P
D.P
D.P
D.P
D.P
D.P
60090
2,060 90160
90 2,200 90500
90 2,20090
2,000 90 900 2,200 7,59090
5,860
350
5,050
110880
110
500
5,530500
1,69
44,
436
250
250
1,10
090
3,00
090
1,00
060
0250
250
5,88
025
0
5,890
110500
5,93
010
0
1,69
44,
436
250
250
1,10
090
3,00
090
1,00
060
025
0
250
5,88
025
0
2,300 840 2,585 8,761 8,944 5,860 1,000 4,400
29,290 5,400
90 2,660 250 425 8,761 8,854 90 4,400 100 1,360 1,000 200 4,000 200
5,890
110500
5,930100
500
5,53
050
0
500
250
5,33
035
0
350
5,050
110880
110 6,500
6,500
6,530
6,53
0
500250
5,330350
6,100
600
5,000
500
500
5,000
600
6,100
1,100 2,390 2,400 600 600 1,200
900 900 900 900 900 900250
900 1,100 2,890 2,400 600
8,08
01,
800
8,08
0
160
4,12
060
02,
400
600
200
160
904,
030
510
902,
400
800
1,50
025
01,
100
9080
090
1,21
090
1,40
01,
100
250
200
250
1,10
090
1,26
090
900
902,
350
250
250
1,10
090
1,26
090
900
902,
350
250
1,69
476
310
02,
924
1,10
01,
800
1,10
02,
924
100
763
1,69
4
14,9
60
200
250
1,10
01,
400
901,
210
9080
090
1,10
025
01,
500
800
2,40
090
510
4,03
090
160
200
600
3,00
04,
120
160
1,800 90 3,500 1,10090
1,10090
1,000 90 2,600
90
20090 2,810 90 7,500
901,000 3,060 600 1,200
30,790 5,400
2,300 840 3,085 9,761 8,944 5,860 1,000 4,400
2,300 90 3,160 250 425 9,761 8,854 90 4,400 100 1,360 1,000 200 4,000 200
600 90 2,560 90160 90
1,100 1,10090 500 90
1,600 90 2,600 90 1,900 1,200 8,590 90 5,860
1,800 90 4,000 1,10090
1,10090
1,600 90 2,00090 200
90 2,810 90 8,500 90 1,000 3,060 600 1,200
90 96090
1,550 90
90 96090
1,55090
1,10
01,
800
1,10
0
700 1,200 1,200
3,00
01,
090
600
600
1,09
03,
000
700 1,200 1,200
860
1,54
0
1,54
086
0
800
800
900 900 900 900 900 900
250 900 900 900 900 900 900 900 250
250 900 900 900 900 900 900 900 250
1,400 600 600 600 1,200 1,000
1,750
190220
190
190220
190
A20
A20
B20
B20
C21
C21
D21
D21
E21
E21
upper levelcantilevered over
mech. ventrequired
upper levelcantilevered over
mech. ventrequired
plaster blind pelmet
plaster blind pelmet
approx. location ofexisting telegraph pole
Tall Cupboard
Tall Cupboard
plumbing duct
plumbing duct
Line of Parapet over
Line of Parapet over
Door heightt.b.c on site
concealedrangehood
concealedrangehood
300mm OH Bench
300mm OH Bench
100mm DiameterRound Post
100mm DiameterRound Post
pantry
RE
F.
WO
appl.
WOROBE
LIN
EN
BUTLERSPANTRY
KIT
CH
EN
PORCH
FOYER
CARPORT
garden
garden
garden
garden
garden
COURTYARD
DINING FAMILY ALFRESCO
BBQ bench
SERVICE COURTYARD
PLUNGE POOLto pool builders specs.
POOL DECK
STUDY
gate
garden
line of deck above
gate
gate
timber arbor
timber arbor
timber arbor
pantry appl.
FW
ROBE
LIN
EN
BUTLERSPANTRY
KIT
CH
EN
PORCH
FOYER
CARPORT
garden
garden
garden
garden
garden
COURTYARD
DINING FAMILYALFRESCO
BBQ bench
SERVICE COURTYARD
PLUNGE POOLto pool builders specs.
POOL DECK
STUDY
gate
garden
garden
line of deck above
gate
gate
timber arbor
timber arbor
timber arbor
villa B
villa A
3020mm ceiling
3020mm ceiling
3020mm ceiling
3020mm ceiling
LIN
EN
FW
LIN
EN
CS
D
CSD
CS
D
CS
D
CSDCS
D
1500
1500
hws
METER BOX
GG
METER BOX
GG
hws
tap
tap
tap
tap
L'D
RY
L'D
RY
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening* If more than one smoke alarm is required they must beinterconnected as per BCA 3.7.2
VILLA B FLOOR AREA
01 GROUND FLOOR
02 FIRST FLOOR
03 CARPORT
04 ALFRESCO
05 PORCH
06 DECK
07 ROOF DECK
Area (m2)
131.21
132.16
36.16
24.36
2.78
15.11
111.74
453.52 m2
VILLA A FLOOR AREA
01 GROUND FLOOR
02 FIRST FLOOR
03 CARPORT
04 ALFRESCO
05 PORCH
06 DECK
07 ROOF DECK
Area (m2)
141.53
141.65
36.16
24.36
2.78
15.11
117.62
479.21 m2
GROUND FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
TOTAL
40.98sqs
45.51sqs
TOTAL
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
6 22
queensland inc.association of
building designers
H 280115
920
920
720
1000
hamper
920
920
920
920
720
1000hamper
920
920
12-06aaw12-18aaw12-12aaw12-22afg 12-06aaw
24-0
6alw
09-24aaw 09-24aaw
27-3
0afg
27-3
0afg
27-11afg
06-24aaw
09-24aaw
24-27stacker
24-3
6sta
cker
12-06aaw12-18aaw12-12aaw12-22afg 12-06aaw
24-0
6alw
09-24aaw 09-24aaw27
-30a
fg
27-3
0afg
27-11afg
06-24aaw
09-24aaw
24-27stacker
24-3
6sta
cker
11
12
13
14
15
16
17
18
19
20
6
7
8
9
11
12
13
14
15
16
17
18
19
20
6
7
8
9
1
2
3
4
1
2
3
4
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
A20
A20
B20
B20
C21
C21
D21
D21
E21
E21
28,490
4,790 9,196 11,304 3,200
1,200 90 3,410 90 9,196 11,154 150 1,990 100 1,110
90 1,110 90 2,210 90 3,490 90 1,750 90 2,00090
1,100 90 2,410 90 2,000 90 2,170 90 4,800 150 1,700600
900
1,200 90 3,410 90 1,10090
1,10090
600 1,15090
1,250 750 90 3,600 90650
850500 90 500
1,170500
90
1,800 90 500 2,400
2,390 2,400 600
7,58
01,
800
7,58
0
690
3,09
03,
000
600
200
1,80
020
060
03,
000
3,09
069
0
903,
600
903,
350
90160
200
1,80
020
016
0 903,
350
903,
600
90
1,50
015
01,
680
2,70
01,
10025
020
01,
800
200
250 1,
100
2,70
01,
680
150
1,50
0
150
1,10
090
1,61
090
1,50
090
1,00
025
02,
200
250
1,00
090
1,50
090
1,61
090
1,10
015
0
150
1,10
052
018
0 1,00
090
2,59
025
02,
200
250
2,59
090
1,00
0180 52
0
1,10
015
0
16,9
60
1,50
01,
983
3,64
745
01,
800
450
3,64
71,
983
1,50
0
1,94
33,
687
250
200
1,80
020
025
03,
687
1,94
3
2,26
090
3,28
025
02,
200
250
3,18
090
2,36
0
1,95
018
01,
000
902,
410
250
2,20
02,
660
901,
200
180
1,75
0
150
1,10
090
300
9060
03,
300
250
2,20
025
03,
400
600
9020
090 1,10
015
0
3,26
7
1,16
71,
200
900
1,18
01,
200
900
900
1,20
01,
380
1,30
088
01,
000
900
1,20
01,
201
3,30
1
1,100
1,10
0
90 1,000
1,78390
29,990
5,290 21,500 3,200
1,200 90 3,910 90 21,350 150 2,090 1,110
90 1,110 90 2,710 90 3,490 90 1,750 90 2,00090
1,100 90 2,410 90 2,000 90 1,48090
1,400 90 5,000 150 1,990 100 1,110
1,200 90 3,910 90 1,10090
1,10090 600
1,15090
1,250 750 90 3,600 90 650 850 500
90
500 800
28090
800500
90
2,890 2,400 600
1,800 90 1,000 2,400
600100
1,100 90
600100
1,100 90
650
450
1,700 600 900 450
650
100
2,50
01,
100
1,10
02,
500
100
250
100
250
250
100
250
90420
90
blind recess
blind recess
Hatched area 2700mm high droppedceiling over LINEN to BATH
Hatched area 2700mm high droppedceiling over LINEN to BATH
Slim Flat Roofto Builders Specs
Slim Flat Roofto Builders Specs
Line of Hood Above
Line of Hood Above
handrail 1000mm High
handrail 1000mm High
Box gutter
1 degree Stramit colorbondklip-lok roof sheeting
box gutter
1 degree Stramit colorbondklip-lok roof sheeting
box gutter
Flashing
Flashing
Box gutter
Slash Hatched area2400mm dropped ceilingover LINEN to Shower
Slash Hatched area2400mm dropped ceilingover LINEN to Shower
AC Duct Space
AC Duct Space
Concealed CisternMedicine Cabinet with Mirror DoorRecessed Lighting Under (150mm Width)
Handrail 1000mm High
Handrail 1000mm High
Flashing
FWFW
ROBEROBE
LINEN
LIN
EN
SITTING
BED 3
BED 2 MASTERSUITE
DECK
flashingover
FW
FWFW
ROBE ROBE
LINEN
LIN
EN
SITTING
BED 3
BED 2
MASTERSUITE DECK
flashingover
villa A
seat
niche0412
900affl
shel
ves
shel
ves
shel
ves
mirror
W.I.R
FWvilla B
seat
shel
ves
mirror
W.I.R
2800mm ceiling
3020mm ceiling
3020mm ceiling
2800mm ceiling
3020mm ceiling
3020mm ceiling
M
M
x2
x2
niche0412
900affl
niche0412
900affl
niche0412
900affl
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening* If more than one smoke alarm is required they must beinterconnected as per BCA 3.7.2
FIRST FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
7 22
queensland inc.association of
building designers
H 280115
06-18afg12-15aaw
24-4
4 bi
-fol
d do
ors
12-1
8aaw
06-18afg12-15aaw
24-4
4 bi
-fol
d do
ors
12-1
8aaw
4
5
6
7
8
9
10
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
12
13
14
15
16
17
18
19
20
D.P
D.P
A20
A20
B20
B20
C21
C21
D21
D21
E21
E21
51090
7,47090
510 14,39060
901,
980
3,50
090
160
250
350
5,13
015
0
510 90 7,47090
5,13
035
025
0
160
903,
500
1,98
090
60
5,300 510 7,650 471 13,449
5,300 8,670 9,000
5,800 8,670 9,000
51090 90
1,10090
1,100 5,09090 510
90 901,100
901,100 5,090
90
5,800 510 7,650 14,90015
05,
130
440
160
5,88
0
160
440
5,13
015
0
5,88
028,860
5,63
025
020
0
4,98
01,
100
6,08
01,
500
200
250
5,63
0
1,50
05,
880
200
1,80
020
05,
880
1,50
0
27,380
1,10
04,
980
1,50
06,
080
1,80
0
390 210
600
11,000
1,483
11,000
483
Box gutter
Stormwater Grate Drain to Builders Specs
Stormwater Grate Drain to Builders Specs
Timber arbor attached to Wall @ 600mm Centres
Handrail1000mmHigh
Handrail1000mmHigh
Timber Panel Shading to Builders specs
Timber arbor attached to Wall @ 600mm Centres
Timber Panel Shading to Builders specs
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
Rendered wall
Rendered wall
roof
fall
roof
fall
ROOF DECK
ROOF DECK
villa A
villa B
deck
fall
deck
fall
LIVING ROOM
LIVING ROOM
BBQ
BBQ
CARPET
CARPET
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening* If more than one smoke alarm is required they must beinterconnected as per BCA 3.7.2
ROOF DECK PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
8 22
queensland inc.association of
building designers
H 280115
500
3,02
0
475
3,02
0
475
2,44
0
3,32
0
2,00
082
050
0
2,40
062
0
795
2,72
060
0
2,94
0
900
10,6
80
375
3,72
0
1,00
01,
200
1,00
0
250
500
Rendered BrickworkCemintel 'BARESTONE'sheet cladding
Selected Timber cladding Open timber pergola
Open timber pergolaCemintel 'BARESTONE'sheet cladding
Cemintel 'BARESTONE'sheet cladding
Selected Timber cladding
Timber deckingaround pool
1000mm high FG handrail,as per BCA 3.9.2
Selected Timber cladding
Rendered 60mm NRGgreenboard wall cladding
1200mm high FG handrail,as per BCA 3.9.2
Hood
1000mm high FG handrail,as per BCA 3.9.2
Selected Timber cladding Selected Timber cladding
Brickup base rqd
1000mm high FG handrail,as per BCA 3.9.2
Flashing
Timber Panel Shading to Builders Specs
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
ELEVATION 1 1:100
500
3,02
0
475
3,02
0
475
2,44
0
10,4
30
2,44
050
0
3,89
5
3,62
0
3,89
5
3,62
0
10,4
30
1,00
0
Timber deckingaround pool
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
1200mm high FG pool fence,as per AS1926.1
Open timber pergola
Open timber pergolaCemintel 'BARESTONE'sheet cladding
Galv. steelspiral stair case
Cemintel 'BARESTONE'sheet cladding
Rendered 60mm NRGgreenboard wall cladding
Rendered 60mm NRGgreenboard wall cladding
Brickup base rqd
Selected Timber cladding
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
Open timber pergola
Selected Timber claddingSelected Timber cladding
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
ELEVATION 2 1:100
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
9 22
queensland inc.association of
building designers
H 280115
250
500
3,02
0
475
3,02
0
475
2,44
0
10,6
80
900
495
3,62
0
4,11
5
3,32
0
2,82
050
0
3,39
5
1,00
0
3,28
5
3,39
5
Rendered BrickworkCemintel 'BARESTONE'sheet cladding
Selected Timber claddingOpen timber pergola
Open timber pergolaCemintel 'BARESTONE'sheet cladding
Cemintel 'BARESTONE'sheet cladding
Timber deckingaround pool
1000mm high FG handrail,as per BCA 3.9.2
Selected Timber cladding
Rendered 60mm NRGgreenboard wall cladding
Galv. steelspiral stair case
Selected Timber cladding
Selected Timber cladding
1200mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
Hood
Brickup base rqd
Flashing
Timber Panel Shading to Builders Specs
1000mm high FG handrail,as per BCA 3.9.2
FLFL
FLFL
CLCL
CLCL
FLFL
CLCL
ELEVATION 3 1:100
750
3,02
0
475
3,02
0
475
2,44
0
10,6
80
2,94
0
2,44
050
0
10,6
80 4,11
5
795
2,72
060
0
2,00
0 3,32
0
2,82
050
0
2,40
0
Cemintel 'BARESTONE'sheet cladding
Selected Timber cladding
Cemintel 'BARESTONE'sheet cladding
Silicon butt-jointedFG to ceiling
Open timber pergola Selected Timber cladding
Cemintel 'BARESTONE'sheet cladding
Silicon butt-jointedFG to ceiling
Titl panelconc. fencing
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
ELEVATION 4 1:100
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
10 22
queensland inc.association of
building designers
H 280115
250
500
3,02
0
475
3,02
0
475
2,44
0
10,6
804,11
5
2,40
062
0
795
2,72
060
0
3,32
0
2,82
050
0
375
1,00
0 1,20
0
500
900
700
1,20
0
Cemintel 'BARESTONE'sheet cladding
Selected Timber cladding
Open timber pergolaCemintel 'BARESTONE'sheet cladding
Cemintel 'BARESTONE'sheet cladding
Timber deckingaround pool
1000mm high FG handrail,as per BCA 3.9.2
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
Open timber pergola
Cemintel 'BARESTONE'sheet cladding
Rendered Brickwork Open timber pergolaBrickup base rqd
1200mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
Non removable screen toAll bedroom windows on first floor
Timber Panel Shading to Builders SpecsStramit colorbond capping to top
of all parapet walls
FLFL
FLFL
CLCL
CLCL
FLFL
CLCL
ELEVATION 5 1:100
500
3,02
0
475
3,02
0
475
2,44
0
8,49
010,6
80 4,11
5
795
2,72
060
0
2,40
062
0
3,32
0
2,82
050
0
900
700
1,20
0
250
500
Cemintel 'BARESTONE'sheet cladding
Selected Timber cladding
Open timber pergolaCemintel 'BARESTONE'sheet cladding
Cemintel 'BARESTONE'sheet cladding
Timber deckingaround pool
1000mm high FG handrail,as per BCA 3.9.2
Stramit colorbond capping to topof all parapet walls
Open timber pergola
Cemintel 'BARESTONE'sheet cladding
Rendered BrickworkOpen timber pergola Brickup base rqd
1200mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
Non removable screen toAll bedroom windows on first floor
Timber Panel Shading to Builders Specs
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
ELEVATION 6 1:100
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
11 22
queensland inc.association of
building designers
H 280115
820
920
820820
820
1500
820
920
820820
820
1500
720
720
24-48 panelift door
24-0
7afg
24-3
6 bi
-fol
d do
ors
24-09afg
07-28afg07-20afg
24-09alw 24-48SD
24-0
6alw
15-3
0afg
30-24afg
15-05afg
24-09alw
24-09alw
24-09alw
24-4
8 pa
nelif
t doo
r
24-0
7afg
24-3
6 bi
-fol
d do
ors
24-09afg
07-28afg07-20afg
24-09alw 24-48SD24-0
6alw
15-3
0afg
30-24afg
15-05afg
24-09alw
24-09alw
24-09alw
1 2 3 4
12
1
2
12345678
11
12
13
14
1
2
3
4
5
6
7
8
9
1 2 3 4
12
1
2
12345678
11
12
13
14
1
2
3
4
5
6
7
8
9
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
TV
P.
P.
P.
P.
External Lights
External Lights
External Lights
upper level
waterproof dppfor external use
TV
P.
P.
P.
P.
External Lights
External Lights
External Lights
upper level
for Pool
waterproof dppfor external use
hws
METER BOX
GG
METER BOX
GG
hws
tap
tap
tap
tap
spp for HPspp for DWUnd
er b
ench
spp for MW
spp for REF
spp for R'HOOD
spp for remotecontrolled paneliftdoor two handsetssupplied
spp for remotecontrolled paneliftdoor two handsetssupplied
spp for R'HOOD
spp for REF
spp for MW
spp for MW
spp for MW
spp for DW
spp for DW
spp for DW
spp for HP
Und
er b
ench
Abo
ve b
ench
Abo
ve b
ench
for Pool
GROUND FLOOR ELECTRICAL PLAN
SCALE 1:100
PROVIDE 80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES
CLIENT WITH ELECTRICIANCONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE
P.
ELECTRICAL LEGEND
TV
CEILING FAN LIGHT
PHONE OUTLET
2 GLOBE FAN, HEAT, LIGHT
METER BOX
SINGLE GPO'S - 1050 OFF FLOOR
SINGLE GPO'S - 300 OFF FLOOR
DOUBLE GPO'S - 300 OFF FLOOR
TV ANTENNA POINT
EXHAUST FAN
FLUORESCENT LIGHT
PHONE OUTLET-300 OFF FLOOR
CEILING FAN
DOWN LIGHT
WALL LIGHT
SMOKE DETECTOR
FLOOD LIGHT
PENCIL SPOT
SPECIAL LIGHT
SWITCH POINTS @ 1350 OFF FLOOR
DOUBLE GPO'S - 1050 OFF FLOOR
CEILING LIGHT (BATTEN HOLD)
NOTES:
* ALL external power points to be weather-proof
** ALL ELECTRICAL POINTS T.B.C ON SITE BYCLIENT AND ELECTRICIAN **
FP.FLUORESCENT PENCIL SPOT
FIBER OPTIC CABLES LAID FOR SMART HOUSE COMMUNITY
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
12 22
queensland inc.association of
building designers
H 280115
920
920
720
1000
hamper
920
920
920
920
720
1000hamper
920
920
12-06aaw12-18aaw12-12aaw12-22afg 12-06aaw
24-0
6alw
09-24aaw 09-24aaw
27-3
0afg
27-3
0afg
27-11afg
06-24aaw
09-24aaw
24-27stacker
24-3
6sta
cker
12-06aaw12-18aaw12-12aaw12-22afg 12-06aaw
24-0
6alw
09-24aaw 09-24aaw
27-3
0afg
27-3
0afg
27-11afg
06-24aaw
09-24aaw
24-27stacker
24-3
6sta
cker
11
12
13
14
15
16
17
18
19
20
6
7
8
9
11
12
13
14
15
16
17
18
19
20
6
7
8
9
1
2
3
4
1
2
3
4
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
M
M
P.
P.
P.
upper level
lower level
P.
P.
P.
upper level
lower level
TV
TV
FIRST FLOOR ELECTRICAL PLAN
SCALE 1:100
PROVIDE 80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES
CLIENT WITH ELECTRICIANCONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE
P.
ELECTRICAL LEGEND
TV
CEILING FAN LIGHT
PHONE OUTLET
2 GLOBE FAN, HEAT, LIGHT
METER BOX
SINGLE GPO'S - 1050 OFF FLOOR
SINGLE GPO'S - 300 OFF FLOOR
DOUBLE GPO'S - 300 OFF FLOOR
TV ANTENNA POINT
EXHAUST FAN
FLUORESCENT LIGHT
PHONE OUTLET-300 OFF FLOOR
CEILING FAN
DOWN LIGHT
WALL LIGHT
SMOKE DETECTOR
FLOOD LIGHT
PENCIL SPOT
SPECIAL LIGHT
SWITCH POINTS @ 1350 OFF FLOOR
DOUBLE GPO'S - 1050 OFF FLOOR
CEILING LIGHT (BATTEN HOLD)
NOTES:
* ALL external power points to be weather-proof
** ALL ELECTRICAL POINTS T.B.C ON SITE BYCLIENT AND ELECTRICIAN **
FP.FLUORESCENT PENCIL SPOT
FIBER OPTIC CABLES LAID FOR SMART HOUSE COMMUNITY
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
13 22
queensland inc.association of
building designers
H 280115
06-18afg12-15aaw
24-4
4 bi
-fol
d do
ors
12-1
8aaw
06-18afg12-15aaw
24-4
4 bi
-fol
d do
ors
12-1
8aaw
4
5
6
7
8
9
10
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
12
13
14
15
16
17
18
19
20
D.P
D.P
roof
fall
roof
fall
waterproof dppfor external use
lower level
waterproof dppfor external use
lower level
deck
fall
deck
fall
ROOF DECK ELECTRICAL PLAN
SCALE 1:100
PROVIDE 80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES
CLIENT WITH ELECTRICIANCONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE
P.
ELECTRICAL LEGEND
TV
CEILING FAN LIGHT
PHONE OUTLET
2 GLOBE FAN, HEAT, LIGHT
METER BOX
SINGLE GPO'S - 1050 OFF FLOOR
SINGLE GPO'S - 300 OFF FLOOR
DOUBLE GPO'S - 300 OFF FLOOR
TV ANTENNA POINT
EXHAUST FAN
FLUORESCENT LIGHT
PHONE OUTLET-300 OFF FLOOR
CEILING FAN
DOWN LIGHT
WALL LIGHT
SMOKE DETECTOR
FLOOD LIGHT
PENCIL SPOT
SPECIAL LIGHT
SWITCH POINTS @ 1350 OFF FLOOR
DOUBLE GPO'S - 1050 OFF FLOOR
CEILING LIGHT (BATTEN HOLD)
NOTES:
* ALL external power points to be weather-proof
** ALL ELECTRICAL POINTS T.B.C ON SITE BYCLIENT AND ELECTRICIAN **
FP.FLUORESCENT PENCIL SPOT
FIBER OPTIC CABLES LAID FOR SMART HOUSE COMMUNITY
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
14 22
queensland inc.association of
building designers
H 280115
7500 Max
METAL BATTENS @ 900 cts
MAIN ROOF
DIMENSION 'A'
3 COMMON FOR OPENING < 2700
TIMBER LISTSEAS. PINEWALL FRAMING
4 COMMON FOR OPENING < 3600
2 COMMON FOR OPENING < 1800
3000 MAX. HT.
LINTELS & BEAMS
ROOF BATTENS
ROOF FRAMING
JAMB STUDS
NOGGING
NON-LOADBEARING
STUDS
LOADBEARING
STUDS
BOTTOM PLATE
NON-LOADBEARINGTOP PLATE
LOADBEARINGTOP PLATE
OR F27 HARDWOOD
MGP12 TUAN PINE
SHEET METAL ROOFROOF MATERIAL
2/90 x 35 (MGP12)
90 x 35 (MGP10)
90 x 35 (MGP10)ON SOLID BLOCKING
90 x 35 (MGP12) @ 450 CTS. TO 3000MAX HEIGHT WITH NOGGING @ 1350CTS
90 x 35 (MGP10) @ 450 CTS.
90 x 35 (MGP10) STAGGERED@ 1350 CTS
N3/SR 90mm
ALL CONSTRUCTION SHALL BE NOT LESSTHAN AS PRESCRIBED IN THE BUILDING ACTand THE BUILDING CODE of AUST. & A.S.1684.2-2010.
ENGINEER DESIGNED ROOF TRUSSES @600 CTS. (SEAS. PINE)
SILL MEMBERS
LINTEL TRIMMER & SILL
MAX OPENING
BASED ON 2100 DOOR/ WINDOW HEAD HEIGHT
90 X 35 MGP122/90 X 353/90 X 354/90 X 35
2400270033003600
1/Framing anchor6/2.8 dia nails at each
end
SLAB
TOP PLATE TO
9.21 (d)12kN
9.13
9.13
12kN 9.20 (c)
FIXING OF
No
TABLE UPLIFT
FORCE No
METHODFIGURE
OF FIXING
ROOF BATTEN TO
TRUSS / RAFTER
9.14 9.25 (d)
9.21 (b)9.13TRUSS / RAFTER
TO TOP PLATE
1/75mm No14 type 17
screw
TIE DOWN FIXINGS
LINTEL TIE DOWN
(EACH SIDE OF
OPENING) RLW
7500
30 x 0.8 GI strap.4/2.8 dia nails each
end to stud
30 x 0.8 GI strap.
6/2.8 dia nails each
end to stud
9.13
9.13
M12 rod
M16 rod
9.13
9.13
5.9kN
8.4kN
20kN
35kN
9.20 (a)
9.20 (a)
9.20 (c)
9.20 (d)
1.6 kN
6.0 kN
M12 rods cast into
slab at 1200mm crts.
Windows>1200 wide
see top plate to lintel
TOP PLATE
TO LINTEL
30 x 0.8 GI strap @
900 cts looped under
each end. 4/2.8 dia
nails each end
MAX OPENING
900
1500
3900
4200
1 2 3 4
12
1
2
12345678
11
12
13
14
1
2
3
4
5
6
7
8
9
1 2 3 4
121
2
12345678
11
12
13
14
1
2
3
4
5
6
7
8
9
Ste
el P
orta
l Fra
me
Ste
el P
orta
l Fra
me
Ste
el P
orta
l Fra
me
Ste
el P
orta
l Fra
me
TRUSSES & LINTELS AS PER
TRUSS MANUFACTURERS
SPECIFICATIONS
GROUND FLOOR BRACING PLAN
SCALE 1:100
TIMBER FRAME & TRUSSES3020mm PITCHING HEIGHT1 Deg ROOF PITCHCOLORBOND SHEET ROOF
----------------------------
BRACING LEGEND
TB4B Structural pine ply 7mm or F27 4mm 6 kN/m with anchor rods or with anchor bolts and nailing at 50mm crs top and bottom
----------------------------TB1 Galvanised steel angle 1.5 kN/m
NOTE:* Provide three studs under each end ofTG's, provide four studs under each end ofGT's.* Hardwood top plate under GT's, TG's andunder loadbearing points.* Edge nailng of ply brace to be at 50mmcentres, no tiedown rods are required.* M12 rods to brick piers, typical, cavityfilled.* ALL 600mm TB4B panels to have an M12rod to each end.
N3/SRB
RA
CIN
G R
EQ
UIR
ED
BR
AC
ING
PR
OV
IDE
D
BRACING REQUIRED
257.
34 k
N23
2.20
kN
83.62 kN
BRACING PROVIDED 86.40 kN
NOTES:* Engineer to specify ALL roof strapping and any
additional bracing that may be reqd.
* Brickwork & galv. lintel over external openings 3000mm
wide or less, rendered harditex over openings greater
ALL LINTELS UNDER POINT LOADS TO BE CONFIRMED BY TRUSS MANUFACTURER / ENGINEER
----------------------------
TB4B-I Structural pine ply 7mm or F27 4mm 5 kN/m with anchor rods or with anchor bolts and nailing at 50mm crs top and bottom----------------------------
BLOCK 190 core filled concrete with M12 rod 15 kN to each end (1200mm panel)----------------------------
BRICK PIERS 350sq. core filled with M12 rod 2.25 kN
BR
AC
ING
RE
QU
IRE
DB
RA
CIN
G P
RO
VID
ED
BRACING REQUIRED
269.
12 k
N23
2.20
kN
BRACING PROVIDED
Villa A
Villa B
86.40 kN
83.97 kN
Bracing T.B.C by ICON ENGINEERS
Bracing T.B.C by ICON ENGINEERS
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
15 22
queensland inc.association of
building designers
H 280115
7500 Max
METAL BATTENS @ 900 cts
MAIN ROOF
DIMENSION 'A'
3 COMMON FOR OPENING < 2700
TIMBER LISTSEAS. PINEWALL FRAMING
4 COMMON FOR OPENING < 3600
2 COMMON FOR OPENING < 1800
3000 MAX. HT.
LINTELS & BEAMS
ROOF BATTENS
ROOF FRAMING
JAMB STUDS
NOGGING
NON-LOADBEARING
STUDS
LOADBEARING
STUDS
BOTTOM PLATE
NON-LOADBEARINGTOP PLATE
LOADBEARINGTOP PLATE
OR F27 HARDWOOD
MGP12 TUAN PINE
SHEET METAL ROOFROOF MATERIAL
2/90 x 35 (MGP12)
90 x 35 (MGP10)
90 x 35 (MGP10)ON SOLID BLOCKING
90 x 35 (MGP12) @ 450 CTS. TO 3000MAX HEIGHT WITH NOGGING @ 1350CTS
90 x 35 (MGP10) @ 450 CTS.
90 x 35 (MGP10) STAGGERED@ 1350 CTS
N3/SR 90mm
ALL CONSTRUCTION SHALL BE NOT LESSTHAN AS PRESCRIBED IN THE BUILDING ACTand THE BUILDING CODE of AUST. & A.S.1684.2-2010.
ENGINEER DESIGNED ROOF TRUSSES @600 CTS. (SEAS. PINE)
SILL MEMBERS
LINTEL TRIMMER & SILL
MAX OPENING
BASED ON 2100 DOOR/ WINDOW HEAD HEIGHT
90 X 35 MGP122/90 X 353/90 X 354/90 X 35
2400270033003600
1/Framing anchor6/2.8 dia nails at each
end
SLAB
TOP PLATE TO
9.21 (d)12kN
9.13
9.13
12kN 9.20 (c)
FIXING OF
No
TABLE UPLIFT
FORCE No
METHODFIGURE
OF FIXING
ROOF BATTEN TO
TRUSS / RAFTER
9.14 9.25 (d)
9.21 (b)9.13TRUSS / RAFTER
TO TOP PLATE
1/75mm No14 type 17
screw
TIE DOWN FIXINGS
LINTEL TIE DOWN
(EACH SIDE OF
OPENING) RLW
7500
30 x 0.8 GI strap.4/2.8 dia nails each
end to stud
30 x 0.8 GI strap.
6/2.8 dia nails each
end to stud
9.13
9.13
M12 rod
M16 rod
9.13
9.13
5.9kN
8.4kN
20kN
35kN
9.20 (a)
9.20 (a)
9.20 (c)
9.20 (d)
1.6 kN
6.0 kN
M12 rods cast into
slab at 1200mm crts.
Windows>1200 wide
see top plate to lintel
TOP PLATE
TO LINTEL
30 x 0.8 GI strap @
900 cts looped under
each end. 4/2.8 dia
nails each end
MAX OPENING
900
1500
3900
4200
11
12
13
14
15
16
17
18
19
20
6
7
8
9
11
12
13
14
15
16
17
18
19
20
6
7
8
9
1
2
3
4
1
2
3
4
M
M
TRUSSES & LINTELS AS PER
TRUSS MANUFACTURERS
SPECIFICATIONS
FIRST FLOOR BRACING PLAN
SCALE 1:100
BR
AC
ING
RE
QU
IRE
DB
RA
CIN
G P
RO
VID
ED
BRACING REQUIRED
121.
56 k
N12
4.00
kN
45.22 kN
BRACING PROVIDED 48.60 kN
ALL LINTELS UNDER POINT LOADS TO BE CONFIRMED BY TRUSS MANUFACTURER / ENGINEER
----------------------------
BRACING LEGEND
TB4B Structural pine ply 7mm or F27 4mm 6 kN/m with anchor rods or with anchor bolts and nailing at 50mm crs top and bottom
----------------------------TB1 Galvanised steel angle 1.5 kN/m
NOTE:* Provide three studs under each end ofTG's, provide four studs under each end ofGT's.* Hardwood top plate under GT's, TG's andunder loadbearing points.* Edge nailng of ply brace to be at 50mmcentres, no tiedown rods are required.* M12 rods to brick piers, typical, cavityfilled.* ALL 600mm TB4B panels to have an M12rod to each end.
----------------------------
TB4B-I Structural pine ply 7mm or F27 4mm 5 kN/m with anchor rods or with anchor bolts and nailing at 50mm crs top and bottom----------------------------
BLOCK 190 core filled concrete with M12 rod 15 kN to each end (1200mm panel)----------------------------
BRICK PIERS 350sq. core filled with M12 rod 2.25 kN
TIMBER FRAME & TRUSSES3020mm PITCHING HEIGHT1 Deg ROOF PITCHCOLORBOND SHEET ROOF
N3/SRNOTES:* Engineer to specify ALL roof strapping and any
additional bracing that may be reqd.
* Brickwork & galv. lintel over external openings 3000mm
wide or less, rendered harditex over openings greater
BR
AC
ING
RE
QU
IRE
DB
RA
CIN
G P
RO
VID
ED
BRACING REQUIRED
126.
00 k
N12
9.60
kN
BRACING PROVIDED
Villa A
Villa B
48.60 kN
45.55 kN
Bracing T.B.C by ICON ENGINEERS
Bracing T.B.C by ICON ENGINEERS
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
16 22
queensland inc.association of
building designers
H 280115
7500 Max
METAL BATTENS @ 900 cts
MAIN ROOF
DIMENSION 'A'
3 COMMON FOR OPENING < 2700
TIMBER LISTSEAS. PINEWALL FRAMING
4 COMMON FOR OPENING < 3600
2 COMMON FOR OPENING < 1800
3000 MAX. HT.
LINTELS & BEAMS
ROOF BATTENS
ROOF FRAMING
JAMB STUDS
NOGGING
NON-LOADBEARING
STUDS
LOADBEARING
STUDS
BOTTOM PLATE
NON-LOADBEARINGTOP PLATE
LOADBEARINGTOP PLATE
OR F27 HARDWOOD
MGP12 TUAN PINE
SHEET METAL ROOFROOF MATERIAL
2/90 x 35 (MGP12)
90 x 35 (MGP10)
90 x 35 (MGP10)ON SOLID BLOCKING
90 x 35 (MGP12) @ 450 CTS. TO 3000MAX HEIGHT WITH NOGGING @ 1350CTS
90 x 35 (MGP10) @ 450 CTS.
90 x 35 (MGP10) STAGGERED@ 1350 CTS
N3/SR 90mm
ALL CONSTRUCTION SHALL BE NOT LESSTHAN AS PRESCRIBED IN THE BUILDING ACTand THE BUILDING CODE of AUST. & A.S.1684.2-2010.
ENGINEER DESIGNED ROOF TRUSSES @600 CTS. (SEAS. PINE)
SILL MEMBERS
LINTEL TRIMMER & SILL
MAX OPENING
BASED ON 2100 DOOR/ WINDOW HEAD HEIGHT
1/Framing anchor
6/2.8 dia nails at eachend
SLAB
TOP PLATE TO
9.21 (d)12kN
9.13
9.13
12kN 9.20 (c)
FIXING OF
No
TABLE UPLIFT
FORCE No
METHODFIGURE
OF FIXING
ROOF BATTEN TO
TRUSS / RAFTER
9.14 9.25 (d)
9.21 (b)9.13TRUSS / RAFTER
TO TOP PLATE
1/75mm No14 type 17screw
TIE DOWN FIXINGS
LINTEL TIE DOWN
(EACH SIDE OF
OPENING) RLW
7500
30 x 0.8 GI strap.
4/2.8 dia nails eachend to stud
30 x 0.8 GI strap.
6/2.8 dia nails each
end to stud
9.13
9.13
M12 rod
M16 rod
9.13
9.13
5.9kN
8.4kN
20kN
35kN
9.20 (a)
9.20 (a)
9.20 (c)
9.20 (d)
1.6 kN
6.0 kN
M12 rods cast into
slab at 1200mm crts.
Windows>1200 widesee top plate to lintel
TOP PLATE
TO LINTEL
30 x 0.8 GI strap @900 cts looped under
each end. 4/2.8 dia
nails each end
90 X 35 MGP122/90 X 353/90 X 354/90 X 35
2400270033003600
MAX OPENING
900
1500
3900
4200
4
5
6
7
8
9
10
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
12
13
14
15
16
17
18
19
20
roof
fall
roof
fall
deck
fall
deck
fall
TRUSSES & LINTELS AS PER
TRUSS MANUFACTURERS
SPECIFICATIONS
ROOF DECK FLOOR BRACING PLAN
SCALE 1:100
BR
AC
ING
RE
QU
IRE
DB
RA
CIN
G P
RO
VID
ED
BRACING REQUIRED
11.0
3 kN
14.4
0 kN
13.98 kN
BRACING PROVIDED 14.40 kN
ALL LINTELS UNDER POINT LOADS TO BE CONFIRMED BY TRUSS MANUFACTURER / ENGINEER
----------------------------
BRACING LEGEND
TB4B Structural pine ply 7mm or F27 4mm 6 kN/m with anchor rods or with anchor bolts and nailing at 50mm crs top and bottom
----------------------------TB1 Galvanised steel angle 1.5 kN/m
NOTE:* Provide three studs under each end ofTG's, provide four studs under each end ofGT's.* Hardwood top plate under GT's, TG's andunder loadbearing points.* Edge nailng of ply brace to be at 50mmcentres, no tiedown rods are required.* M12 rods to brick piers, typical, cavityfilled.* ALL 600mm TB4B panels to have an M12rod to each end.
----------------------------
TB4B-I Structural pine ply 7mm or F27 4mm 5 kN/m with anchor rods or with anchor bolts and nailing at 50mm crs top and bottom----------------------------
BLOCK 190 core filled concrete with M12 rod 15 kN to each end (1200mm panel)----------------------------
BRICK PIERS 350sq. core filled with M12 rod 2.25 kN
TIMBER FRAME & TRUSSES2440mm PITCHING HEIGHT1 Deg ROOF PITCHCOLORBOND SHEET ROOF
N3/SRNOTES:* Engineer to specify ALL roof strapping and any
additional bracing that may be reqd.
* Brickwork & galv. lintel over external openings 3000mm
wide or less, rendered harditex over openings greater
Villa A & Beach rqd. prvd.
Bracing T.B.C by ICON ENGINEERS
Bracing T.B.C by ICON ENGINEERS
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
17 22
queensland inc.association of
building designers
H 280115
2,300 600 2,900 425 18,705
2,900 22,030 4,060 600 1,200
900
600
6,22
036
01,
800
360
6,22
060
090
0
160
4,12
03,
000
600
200
1,80
080
03,
000
4,12
016
0
4,28
01,
460
1,54
060
020
01,
800
200
600
1,54
01,
460
4,28
0
8,08
01,
800
8,08
0
17,9
60
2,900 20,530 4,060 600 1,200
8,388 29,290 5,400
7,742 30,790 5,400
17,9
60
3,53
94,
466
900
150
900
4,46
63,
539
2,61
417
14,
284
1,83
515
01,
835
4,28
417
12,
614
1,50
05,
480
1,10
01,
800
1,10
05,
480
1,50
0
5,48
065
025
020
01,
800
200
250
650
5,48
0
6,38
02,
200
6,38
0
4,060 600 1,200
7,742 1,100 2,890 2,400 600 2,290 2,000
8,768 1,100 2,390 2,400 600 2,290 2,000
2,300 600 2,400 425 17,705
6,500
9,033
6,800
8,126
6,654
1,0154,464
6,500
6,933
6,800
8,126
6,654
1,0154,464
500
5,930100
6,53
0
750
5,680100
500
5,53
0
500
100
5,93
0
500
100
5,68
0
750
6,530500
5,530500
900
2,064
1,5601,400160
2,20
0
1,02
5150 1,
025
2,06
4
900
1,56
0
160
1,40
0
1,10
0
650
250
200
1,10
0
200
250
650
4,400 1,000
900
150
900
1,95
0
1,100
5,400100
1,100
5,400100
6,600
5005,600
500
500
5,600500
160
900
600
840 2,585
976
976
600
1,800
1,800
600
840 3,085
160
600
900
200
200
2,300 3,425 8,761 8,944 5,860 1,000 4,400
2,300 3,925 9,761 8,944 5,860 1,000 4,400
3,87
4
1,410
1,410
3,87
4
2,24
02,
240
9,580
9,58055
0
550
4,770
4,770
24,286
22,816
200
200
200
200
200
200
550
550
1,300
1,300
Slab & footing design to engineers detail
Column pad footing toengineers detail
Slab & footing design to engineers detail
Column pad footing toengineers detail
sink
sinksink
tub
sink
sink
basin
fw
wc
sink
tub
basin
fw
wc
PADRL 3.500mFFLRL 4.000m
(all levels t.b.c on site)
100mmstepdown
100mmstepdown
100m
mst
epdo
wn
100m
mst
epdo
wn
100mmstepdown
100mmstepdown
700mmstepdown
700mmstepdown
700mmstepdown
700mmstepdown
wet area
wet area
Diagonal Dimension
Diagonal DimensionPADRL 3.500mFFLRL 4.000m
(all levels t.b.c on site)
PLUNGE POOLto pool builders specs.
PLUNGE POOLto pool builders specs.
9.72 Degree
9.72 Degree
PADRL 3.250mFFLRL 3.350m
(all levels t.b.c on site)
PADRL 3.250mFFLRL 3.350m
(all levels t.b.c on site)
GROUND FLOOR SLAB PLAN
SCALE 1:100
NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
18 22
queensland inc.association of
building designers
H 280115
Connection T.B.C by Engineer
Connection T.B.C by Engineer
Connection T.B.C by Engineer
Connection T.B.C by Engineer
Connection T.B.C by Engineer
Connection T.B.C by Engineer
Connection T.B.C by Engineer Stair Void
Stair Void
FIRST FLOOR JOIST PLAN
SCALE 1:100
NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer
JOIST LAYOUT IS DIAGRAMMATIC ONLY - ENGINEER TO CONFIRMALL MEMBERS TO BE SPECIFIED BY ENGINEER
ALL BEAMS TO BE IN PLANE OF FLOOR JOISTS WHERE POSSIBLE
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
19 22
queensland inc.association of
building designers
H 280115
Stair Void
Stair Void
ROOF DECK FLOOR JOIST PLAN
SCALE 1:100
NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer
JOIST LAYOUT IS DIAGRAMMATIC ONLY - ENGINEER TO CONFIRMALL MEMBERS TO BE SPECIFIED BY ENGINEER
ALL BEAMS TO BE IN PLANE OF FLOOR JOISTS WHERE POSSIBLE
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
20 22
queensland inc.association of
building designers
H 280115
500
3,02
0
475
3,02
0
475
2,44
0
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
1200mm highhandrail
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
Bulkhead 200mm down
Bulkhead 320mm down
SECTION 1:100
5A
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
BUTLERSPANTRY
KITCHENPORCH FOYER
CARPORT
DINING FAMILY ALFRESCO
POOL DECK
timber arbor
villa A
SITTING BED 2 MASTER SUITE DECKW.I.R2800mm ceiling3020mm ceiling
STAIRCASE
timber arbor
ROOF DECK
LIVING ROOM
Stair info:Risers @ 175mmGoing @ 300mm
Slab & footings as per soilengineers specs
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Trusses toManufactureres Details
Slab & footings(brick up Base rqd)as per soil engineers specs
brick up Base rqdas per soil engineers specs
NGL
Binders @ 3000 Ctrs
Floor Joists @ 450 CtrsFloor Joists @ 450 Ctrs
Binders @ 3000 Ctrs
Floor Joists @ 450 Ctrs
Deck Joists @ 450 Ctrs
3,02
0
475
3,02
0
475
2,44
0
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
1200mm highhandrail
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
Bulkhead 200mm down
SECTION 1:100
5B
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
study bench
KITCHENFOYER
CARPORT
DINING FAMILY ALFRESCO
PLUNGE POOLto pool builders specs.
STUDY
villa B
LINENBED 3 BED 2 MASTER SUITE DECKflashing
over
W.I.R2800mm ceiling3020mm ceiling
timber arbor
ROOF DECK
LIVING ROOMSINK & BBQ
650
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Trusses toManufactureres Details
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Trusses toManufactureres Details
Stair info:Risers @ 175mmGoing @ 300mm
Slab & footings as per soilengineers specs
Slab & footings(brick up Base rqd)as per soil engineers specs
Slab & footings(brick up Base rqd)as per soil engineers specs
AC Space in Bulkhead620mm Down
NGL
Binders @ 3000 Ctrs
Floor Joists @ 450 Ctrs
Floor Joists @ 450 Ctrs
Floor Joists @ 450 Ctrs
Binders @ 3000 Ctrs
Binders @ 3000 Ctrs
BOX GUTTERING TO COMPLY WITH BCA PART 3.5.2. AND AS3500.2
fall to downpipesbase board to achieve requiredbox guttering on battened plywood
PARAPET DETAIL TYPICAL 1:20
60mm POLY-FOAM board
flashing continuous under
first roof batten
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area,
FLASHING DETAIL TYPICAL 1:20
Stramit Colorbond flashing to topof all BV walls continuous undergable end wall cladding
Selected cladding asnominated on elevations
Floor joists by engineer
PARAPET DETAIL TYPICAL 1:20
BOX GUTTERING TO COMPLY WITH BCA PART 3.5.2. AND AS3500.2
fall to downpipesbase board to achieve requiredBox guttering on battened plywood
Flashing continuous under
first roof batten
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area,
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
21 22
queensland inc.association of
building designers
H 280115
500
3,02
0
475
3,02
0
475
2,44
0
290
290
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Stramit colorbondklip-lok roof sheeting
box gutter
flashing
flashing
flashing
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
PORCHRO
BE
FOYERSTUDY
BED 3RO
BE
SITTINGBED 3
truss upstandtruss upstand
VOIDabove
PORCH
SECTION 1:100
5C Slab & footings
(brick up Base rqd)as per soil engineers specs
1 degree Trusses toManufactureres Details
1 degree Trusses toManufactureres Details
NGL
Floor Joists @ 450 Ctrs
Binders @ 3000 Ctrs
Floor Joists @ 450 Ctrs
villa A villa B
Binders @ 3000 Ctrs
500
3,02
0
475
3,02
0
475
2,44
0
180
180
1 degree Stramit colorbondklip-lok roof sheeting
1 degree Stramit colorbondklip-lok roof sheeting
box gutter
flashing
1 degree Stramit colorbondklip-lok roof sheeting
box gutterbox gutter
HoodHood
1 degree Stramit colorbondklip-lok roof sheeting
flashing flashing
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
LIN
EN
HALL HALL
HALLHALLSTAIRCASE STAIRCASE
truss upstandtruss upstand
SECTION 1:100
5D
Stair info:Risers @ 175mmGoing @ 300mm
1 degree Trusses toManufactureres Details
1 degree Trusses toManufactureres Details
Stair info:Risers @ 175mmGoing @ 300mm
Slab & footings(brick up Base rqd)
as per soil engineers specs
NGL
Floor Joists
Binders @ 3000 Ctrs
Floor Joists
Binders @ 3000 Ctrs
Floor JoistsFloor Joists
villa A villa B
500
3,02
0
475
3,02
0
475
2,44
0
180
180
box gutterbox gutter
HoodHood
Bulkhead 320mm downBulkhead 620mm down
flashing flashing
1 degree Stramit colorbondklip-lok roof sheeting
box gutter1 degree Stramit colorbond
klip-lok roof sheeting
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
BUTLERSPANTRYKITCHEN
BATHBED 2
LIVING ROOM
SECTION 1:100
5E
LIVING ROOM
truss upstandtruss upstand
Slab & footings(brick up Base rqd)
as per soil engineers specs
AC Space in Bulkhead620mm Down
NGL
1 degree Trusses toManufactureres Details
1 degree Trusses toManufactureres Details
Floor Joists @ 450 CtrsFloor Joists @ 450 Ctrs
Floor Joists @ 450 CtrsFloor Joists @ 450 Ctrs
villa A villa B
Binders @ 3000 CtrsBinders @ 3000 Ctrs
3,02
0
3,02
0
900
700
800
4058
0
2,40
062
0
900
700
4028
028
024
058
0
Bulkhead above OH CabinetOverhead display shelvesto builders specs
FL
CL
FL
CL
Concealed Rangehood
Sink
KITCHEN ELEVATION 1 1:50
Cooktopfg fg
DWSpaceOnly
3,02
0
3,02
0
900
700
800
40
580
2,40
062
0
1,80
060
0
40
580
Bulkhead above OH CabinetBulkhead above OH Cabinet
FL
CL
FL
CL
REF. SpaceOnly
WOCSD to Pantry
WOappl.
KITCHEN ELEVATION 2 1:50
MW Space MW Space
3,02
0
3,02
0
900
700
800
900
2,12
0
2,40
040
580
drawers
Gable End & Bench Top
Bulkhead above OH Cabinet
FL
CL
FL
CL
KITCHEN ELEVATION 3 1:50
DWSpaceOnly
3,02
0
3,02
0
1,10
020
01,
100
2,40
062
0
2,40
030
032
0
900
400
1,10
0
Wall Mount Vanity
AC Space
Bulkhead above Medicine CabinetMedicine Cabinet with Mirror
Mirror
Niche1200mmwide
FL
CL
FL
CL320mm Down Bulkhead620mm Down
Bulkhead
Recessed Lighting under Cabinet
BATH ELEVATION 1:50
Bath
Shower
450mm WIDE UNLESS OTHERWISE NOTED.
TO BE 300mm WIDE & KITCHEN DRAWERS TO BE
CABINETMAKERS DISCRETION, VANITY DRAWER
* DOOR SWINGS & CUPB'DS CONFIGURATIONS TO
NOTE:
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTEREDMEMBER OF
ADRIAN HILLDEVELOPMENTS
PROPOSED DWELLINGS
NUMBER 16ANDREA AVENUE
BROADBEACH WATERS
5536
RH / ST
A 09/05/2014
B 130514C 260514D 030714E 080714F 160914G 230115
SO
CUSTOM
1:100 @ A2
22 22
queensland inc.association of
building designers
H 280115
metal fascia & gutter
600
Sheet metal roof with metal battens @900mm cts
two framing anchor to be fixed to each endof trusses and top plates with 6/2.8 dia' nails
or 30 x 0.8mm looped GI strap with 4/2.8mm
dia' nails each end over trusses to top plate
50mm sand bed
moisture barrier
2440
2120
320
flashing & weephole as
per section 1.4 of the BCA
DPC to underside of
bottom plates
brick on edge sill
flashing & weephole
21° roof pitch
CL
FL
manufacturers printed specifications
TYPICAL BRICK VENEER SECTION
GI partition bracket
D1
-
220mm brick veneer wall
10mm plasterboard wall lining, paint finish
aluminium framed window as selected
timber architrave, as selected
90mm cornice, paint finish as selected
10mm plasterboard ceiling, paint finish
as selected
as selected
or as nominated on plans
or as nominated on plans
12mm Rods at 1200mm cts, each side ofopenings and corners, from top plate to slab.
sarking to roof where applicable
metal batten = topspan 40 fixed by roof manufacture
each endframing anchor with 4/2.8 dia. nails atTiedown to jack trusses may be by oneNotes:
& perimeterTermi-mesh or similar to all slab penetrations
with exposed edge for visual inspection
waffle pod slab as per engineers design
or a
s no
min
ated
or a
s no
min
ated
WHERE 2440mm IS USED600mm O'HANG WITH 25 deg ROOF PITCHCANTELEVERED TRUSSES TO ACHIEVE
Roof trusses @ 600mm centres as per truss
(nomial fixing only)Tie down to floor
not to exceed 20mmMax depth of notch
18x16x1.2mmnominal sectionMetal angle of Min.
to end of stud3/30x2.8mm dia nails
30x0.8mm gal. strap
1:501.5kN/m
TYPICAL METAL ANGLE BRACING (TB1)
and each stud2/50x2.8mm diam nails at each end
1800 min. 2700 max.
30 degs max
NOTE:
bracing wall
90x35mm MPG12 timberbridging piece
TRUSSES PARALLEL TO BRACING WALL
3/75 x 3.33 mmdiameter nails eachend.
Gap to truss
to be @150mm centres.Single sheet vertical nailing
be @50mm centres.vertical join nailing is toare butted together theNote: if two or more panel
plate.under top ribbon150mm GI strap
NOTE:
2/30x0.8mm GI strap fixed to top plates & studs at
each end with 4/2.8mm diam nails.
Internal bracing wall
External wall
TYPICAL FIXING TO TOP OF BRACING WALL 1:20
1:20
1:506.0 kN/m (rods not required)
4mm F27 PLYWOOD BRACING (TB4B)
nail spacing as shown30x2.8mm diam flathead nails
300
150
50
19x19mm timber mould
size as per bracing plan
1:10DETAIL 1finish as selected4.5mm FC soffit sheet
Timber reveal
Min 10mm gap
timber lintel beam, as per
Timber architrave
20
320
250
70
Bracing wall
Bottom chord of truss
TRUSSES PERPENDICULAR TO BRACING WALL
top plate with 4/3.33 diam. nailsof truss bottom chord fixed toBlocking pieces to both sides
35mm gap to truss
1:201:20
T.B.C by engineer
WITNESS DATE
amendmentsdesign drawn by
date
scales
job number
of
Phone (07) 55 203 022Fax (07) 55 203 033PO Box 2845 Burleigh HeadsDC Qld 4220
ABN 73 097 995 616QLD 4219
BSA License No: 1129687Email: [email protected]
PLEASE READ CAREFULLY
IN THE INITAL AGREEMENT AND I UNDERSTAND CHANGES
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO
HEREAFTER MAY NOT BE POSSIBLE. THESE PLANSSUPERSEDE ALL OTHER PREVIOUS PLANS OR SKETCHES.
OWNER/S
Contractor to verify dimensions. Notify designers ofdiscrepancies. Failure to do
so shall void the designers responsibilities.
dimensions take preference.© Copyright reserved in part or whole. Written
THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNS
N.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES RESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDINGBE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANY
Address: 2/71 TownshipDrive, West Burleigh,
sheet #
checked by
windows wider than 1200mm, tohave top plate strapped to lintel@ 1200mm max centres with 30x 0.8 GI strap looped under eachend . 4.2.8 dia nails each end
Provide 1 per 900 sheet of bracing ply 2/30x0.8mm looped GI strapfixed over bridging piece & to underside of top plate with 4/2.8mmdiam nails at each end of straps & to bridging piece.
Suitable for 3900 max opening
30x0.8mm gal. strap3/30x2.8mm dia nailsto end of stud
13 kN capacity connection at each end &intermediately at max 1200 cts Suitable to anchor 1m of bracing ply
Engage minimum 2 trusses per 1m of bracing ply
4.5mm FC soffit lining, paint finish as selected.Flat or raking soffit. refer sections/ builders spec.
N3 / SHEET / brick veneer
N3/SR/brick veneer
RH / STCUSTOM
5536
ADRIAN HILL DEVELOPMENTSNUMBER 16 ANDREA AVENUE
BROADBEACH WATERS <DATEOFISSUE>
22221:100 @ A3
####