208
Digital/Analog Programmable Controller Wiring Systems Technical Data Digital Wiring Systems Analog Wiring Systems Table of Contents Description Page Description Page Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Digital (IFM/XIM and Cables) Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Analog (AIFM and Cables) Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ordering Digital and Analog Wiring Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Selection Tables Bulletin 1746 SLC 500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . 25 Bulletin 1756 ControlLogix IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . 30 Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Bulletin 1771 PLC-5 IFMs, XIMs, AIFMs, and Cables. . . . . . . . . . . . . . . . . . . . 40 IFM-Ready I/O Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Build-to-Order Length Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Specifications Digital IFMs and XIMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Digital Cables and Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Analog IFMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Analog Cables and Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Dimensions Digital IFM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Digital XIM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Analog IFM Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Marking Systems Digital Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Analog Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Web Site Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Prog Controller Wiring Systems

Embed Size (px)

DESCRIPTION

Allen Bradley PLCs

Citation preview

Page 1: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems

Technical Data

Digital Wiring Systems Analog Wiring Systems

Table of ContentsDescription Page Description PageBenefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Digital (IFM/XIM and Cables)

Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Analog (AIFM and Cables)Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Ordering Digital and Analog Wiring Systems. . . . . . . . . . . . . . . . . . . . . . . . . . 23Selection Tables

Bulletin 1746 SLC 500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . 25Bulletin 1756 ControlLogix IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . 30Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Bulletin 1771 PLC-5 IFMs, XIMs, AIFMs, and Cables. . . . . . . . . . . . . . . . . . . . 40IFM-Ready I/O Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Build-to-Order Length Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

SpecificationsDigital IFMs and XIMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Digital Cables and Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Analog IFMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131Analog Cables and Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

DimensionsDigital IFM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Digital XIM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Analog IFM Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

Marking SystemsDigital Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163Analog Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200Web Site Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Page 2: Prog Controller Wiring Systems

2 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsDescription Connecting to Allen-Bradley I/O is convenient with Allen-Bradley Interface Modules and Cables. Unlike conventional terminal blocks, they connect through pre-wired cables to digital and analog I/O for the Bulletin 1746 SLC, Bulletin 1756 ControlLogix, Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin 1771/PLC-5 platforms. The interface modules are mounted onto a standard DIN #3 Rail. Pre-printed adhesive label cards containing field-wiring information are available for each interface module and I/O module combination. Wiring systems are available for over 90 digital I/O modules and over 40 analog I/O modules.

Benefits Reduced Wiring Time

Wiring is completed in a fraction of the time when wiring systems are used as compared with the traditional method of wiring each point to the I/O swing arm and field-side terminal blocks. Pre-wired cables are factory-wired to the I/O wiring arm on one end and a connector for the Interface Module (IFM) on the other. IFMs enhance the capability of the I/O systems with added terminations, field-side LED status indicators, isolation circuits, overcurrent protection, and higher amp outputs. Both standard and specific build-to-order length cables are available, providing the correct length for any panel in a neat, space-efficient wiring solution.

Reduced Wiring Errors

Wiring system cables are pre-tested to ensure 100% accurate connections and eliminate the need for point-to-point checking of wiring. No more crossed wires and loose connections between the I/O module and the terminal block. Even one error in wiring 128 I/O points in a point-to-point system may require a complete check of the wiring. Wiring errors can take several minutes to track down and correct before the panel is ready for startup. When IFMs and cables are snapped in place, they fit every time no need to find the wrong or loose connection, resulting in a much higher rate of success at system startup.

Faster Troubleshooting and Easier Maintenance

Normal terminal blocks cant offer the benefits of IFMs, such as LED indication on each I/O point. Wiring systems improve system startup and ease troubleshooting and maintenance. Diagnostic capabilities in the form of fuses, blown fuse indication, and field-side ON-State LEDs in a reduced space allow maintenance personnel to quickly locate faults, reduce downtime, and improve overall productivity.

Publication 1492-TD008A-EN-P - March 2001

Page 3: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 3

Benefits, Continued Increased Volume and Productivity

Cable interconnections for a wiring system can be up to 30 times faster to install than traditional point-to-point wiring, enabling OEMs and panel builders using wiring systems to build panels faster and produce more machines.

Reduced Wire Preparation and Routing

Pre-wired cables eliminate the time and costs associated with stripping and cutting wires. Routing wires is much easier with wiring systems, since engineers only have to worry about routing one pre-wired cable versus the 20 or 40 wires needed in the traditional wiring method.

Labeling and Marking

Pre-printed, I/O-specific adhesive label strips for quick marking of IFM terminals save labor compared with point-to-point wiring that requires labor-intensive wire markers. Pre-wired cables require no wire labels. Pre-printed I/O-specific labels ensure neat, easy-to-read identification of wires and I/O points for all users.The marking of traditional terminal blocks has even caused some OEMs to move toward a high-tech approach of plotting markers, requiring additional equipment in the form of a plotter system and a PC to run the plotter software.

Simplified Design

Design engineers can simplify their panel drawings by calling out an IFM and pre-wired cable instead of having to detail every single wire and terminal block on their drawings. Simplified panel drawings aid not only the installer, but also the end customer who receives the panel.

Increased DIN Rail Density

An increasing trend in the industry is to pack more products into the same DIN Rail space. Wiring systems support this trend, as they require less DIN Rail space than traditional terminal blocks. For example, if an OEM were to use a 40-point IFM in place of 40 terminal blocks, DIN Rail space can be reduced by more than 50%.

Publication 1492-TD008A-EN-P - March 2001

Page 4: Prog Controller Wiring Systems

4 Digital/Analog Programmable Controller Wiring Systems

Benefits, Continued Increased DIN Rail Density, Continued

All IFMs have terminals for connecting the I/O field wiring. In addition, extra terminal, sensor, fusible IFMs, and relay IFMs contain common terminals that are used as power busses for sensor and actuators. No additional terminal blocks are needed to provide power to the sensors/actuators saving valuable panel/DIN Rail space.To further reduce panel space, narrow IFMs (i.e., Cat. No. 1492-IFM20FN) have been designed. They require 45% less space than the standard length IFMs, making them well-suited for tightly packed enclosures. The high-density narrow IFMs have two rows of 10 field-wiring terminals with an overall length of 60 mm (2.36 in.)

Quality-Looking Panels

The pre-wired cables and IFMs organize the wiring in your panel and provide a consistent look. Pre-printed adhesive labels for the terminals neatly identify field-wiring connections, which correspond to the I/O module address. A large marking area is also available for identifying I/O information on the IFM.

Fewer Parts, Less Inventory and Lower Carrying Cost

A wiring system involves an IFM and the cable, versus the block, barrier, jumper, markers, wires, and swing arms associated with traditional hardwired systems. Therefore, it requires fewer components and, in turn, less inventory and lower carrying costs.

Design Flexibility

To develop a cost-effective system, the hardware components must meet the needs of the design engineer. Rockwell Automation provides the broadest range of digital and analog systems in the industry. Allen-Bradley Wiring Systems deliver a lower life-cycle cost.

Publication 1492-TD008A-EN-P - March 2001

Page 5: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 5

Digital IFM Options and Features

Digital IFMs, similar to groups of terminal blocks, are available with either 20-pin or 40-pin cable connectors. The number of field-side wiring terminals varies with the type of module from one to three terminals per I/O point. LEDs and fuse clips are available on-board the IFMs to customize your wiring system to your application and provide assistance with troubleshooting your control panel. The IFMs are compatible with both the pre-wired cables and the IFM-ready cables.

All of the digital IFMs have the following features:

Keyed cable connector (20- or 40-pin) with locking tabs for easy installation and secure connection of IFMs.

UL Component Recognized (File E113724 Guide NRAQ2); UL recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2); CE Approved; Factory Mutual Listed (File J.I. 3000590) FM approved.

Standard DIN #3 Rail mounting for quick installation.

Large rectangular write-on area acts as built-in group marking carrier for programmable controller rack, module group, and/or slot information.

Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.

High-density field-side wiring terminals allow more connections in less space and accommodate #22…12 AWG wire.

Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules.

Digital IFM

Publication 1492-TD008A-EN-P - March 2001

Page 6: Prog Controller Wiring Systems

6 Digital/Analog Programmable Controller Wiring Systems

Digital IFM Options and Features, Continued

Standard Terminal Modules

Standard terminal IFM modules provide one field-side wiring terminal per programmable controller input or output point, as well as enough terminals for the I/O module power connections. The standard terminal modules are ideal for applications in which the I/O device commons are terminated in the field or remotely from the I/O module panel.

Extra Terminal Modules

Extra terminal modules provide two or four field-side terminals per input or output point. Non-isolated IFMs have two terminals per input or output. Isolated IFMs have two or four terminals per input or output. Non-isolated IFMs have the lower row of extra terminals commoned together in groups of 10 ➊ , to serve as a power bus for the field device commons. Isolated IFMs have terminals isolated into 8 or 16 groups, which allows each group of I/O devices to reference a different power source. The extra terminal modules are beneficial in applications in which the I/O devices are terminated within the same panel as the I/O modules eliminating the need for many additional terminal blocks. These modules are also available with optional field-side status LEDs for troubleshooting inputs and outputs.➊ Except Cat. Nos. 1492-IFM20D24A-2 and -IFM20D120A-2, which are in groups of 20.

Publication 1492-TD008A-EN-P - March 2001

Page 7: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 7

Digital IFM Options and Features, Continued

Sensor Modules

Sensor modules provide three field-side terminals per input point. The middle and lower rows of terminals, commoned together in groups of 18, serve as power busses for 3-wire sensor types of devices eliminating additional terminal blocks and jumpering systems. Optional field-side LEDs identify the on/off condition of the sensor signal. The sensor modules provide a compact method of terminating and powering 24V AC/DC or 120V AC (Cat. No. IFM20F-3 only) 3-wire devices.

LED Modules

Voltage-indicating LEDs are available on the standard, extra terminal, and sensor IFMs. The LEDs provide field-side troubleshooting diagnostics: the on/off status of an input device or the on/off status of the programmable controller output circuit. When used in conjunction with the logic-side programmable controller LEDs, the IFM LEDs can help determine whether a problem resides in the I/O module or field device/wiring. The LED modules have unique circuitry that allows compatibility with sinking or sourcing input or output modules.

Publication 1492-TD008A-EN-P - March 2001

Page 8: Prog Controller Wiring Systems

8 Digital/Analog Programmable Controller Wiring Systems

Digital IFM Options and Features, Continued

Fusible Modules

Fusible modules provide a convenient method of adding overcurrent protection into your programmable controller wiring. These modules have 5 x 20 mm fuse clips on-board and are available with and without blown fuse indication. The 24V or 120V blown fuse indicators reduce the troubleshooting time to locate and replace a blown fuse on the IFM. The fusible modules have an easy-to-remove see-through acrylic cover to prevent objects from contacting fuse circuitry under normal operation. Standard fuse holders reside in the IFM, aiding in the removal of a fuse with a fuse puller (fuses are not included). The fusible modules also have two or four terminals per I/O point to create a power bus for input or output load connections. Fusible modules are available in both isolated and non-isolated versions. There are a select number of fusible IFMs available for input modules.

Relay and Expandable Modules

Relay and Expandable Interface Modules (XIM) were developed to maximize the effectiveness of users applications that require output contact ratings greater than 2 A. Driving large loads up to 10 A for applications such as motor starters is now possible with Bulletin 1492 Wiring Systems. In addition, the Relay Modules provide a means to isolate output points.The Relay and Expandable product line consists of a Relay Master module and Expander Module(s) with expander cable. The Relay Master modules provide the connection for the 20- or 40-pin cable connectors for the pre-wired cable. There are three types of expander XIMs: eight-channel relay, eight-channel fused, and eight-channel feed-through.Expander Module capabilities are offered in eight-channel increments. After using 8 or 16 channels of I/O for relays (master relay module), design engineers can use expander modules for the other I/O point needs. The flexibility means that they work with relays, fuses, and feed-through modules. In addition, the expander modules can be added when system expansion is required.

Publication 1492-TD008A-EN-P - March 2001

Page 9: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 9

Digital IFM Options and Features, Continued

Relay and Expandable Modules, Continued

Relay Master

Relay master XIMs feature field-replaceable relays with 120V or 24V rated coils. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. Other features include coil-side LED indicating the output module status, and transient suppression on each coil. The 24V relay master for 32-point outputs is offered with either 8 or 16 relays on one module.

Relay Expanders

Relay expander XIMs feature eight field-replaceable relays with 120V or 24V rated coils. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. Other features include coil-side LED indicating the output module status, and transient suppression on each coil. An expander cable is provided for connection to the mating module.

Publication 1492-TD008A-EN-P - March 2001

Page 10: Prog Controller Wiring Systems

10 Digital/Analog Programmable Controller Wiring Systems

Digital IFM Options and Features, Continued

Relay and Expandable Modules, Continued

Fusible Expanders

The fusible expander modules feature eight 5 x 20 mm finger-safe fuse holders, blown fuse indicators, and extra terminals for landing two wires per field-side device. They are offered with eight fuse holders for both 24V and 120V applications. An expander cable is provided for connection to the mating module. Fuses are not provided.

Feed-Through Expanders

The feed-through expander modules feature eight channels with extra terminals for landing two wires per field-side device. An expander cable is provided for connection to the mating module.

Publication 1492-TD008A-EN-P - March 2001

Page 11: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 11

Digital IFM Options and Features, Continued Digital Pre-Wired Cables

Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Pre-wired cables, when used with an IFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The pre-wired cables have a removable terminal block or wiring arm at the I/O end of the cable and a cable connector on the other end to connect to the IFM. All of the pre-wired cables use #22 AWG wire and are 100% tested for continuity to make a perfect connection every time. The digital pre-wired cables are offered in four standard lengths of 0.5, 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products. Pre-wired cables are available for many of the 1746 SLC I/O, 1756 ControlLogix I/O, 1769 Compact I/O for CompactLogix and MicroLogix 1500, and 1771 PLC-5 I/O controllers.

Ready-to-Wire Digital Cables

I/O-ready cables have an I/O removable terminal block or wiring arm pre-wired to one end to of the cable and free connectors on the other end for wiring into standard terminal blocks or other type of connectors. I/O-ready cables have individual color-coded conductors for quick wire-to-terminal coordination. The I/O-ready cables use #18 AWG conductors for higher current applications or longer cable runs. The I/O-ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products. Pre-wired cables are available for the Bulletin 1746 SLC I/O, Bulletin 1756 ControlLogix I/O, Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin 1771 PLC-5 I/O controllers.

Pre-Wired Cable and Interface Module

I/O-Ready Cable and Standard Terminal Block

Publication 1492-TD008A-EN-P - March 2001

Page 12: Prog Controller Wiring Systems

12 Digital/Analog Programmable Controller Wiring Systems

Digital IFM Options and Features, Continued

Ready-to-Wire Digital Cables, Continued

IFM-ready cables have a cable connector that attaches to the IFM pre-wired to one end and free connectors ready to wire to I/O modules or other components on the other end. IFM-ready cables use #22 AWG wire and have individual color-coded conductors for quick wire-to-terminal coordination. The digital IFM-ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products.

IFM-Ready Cable and Interface Module

Publication 1492-TD008A-EN-P - March 2001

Page 13: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 13

IFM Cat. No. Explanation for Digital I/O Modules

Important: The following IFM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired IFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.

Status IndicationF No LEDsFN Narrow IFMD24 24V LEDs for input and output modulesD24N Narrow IFM with 24V LEDsD24A 24V LEDs for input modulesDS24 Isolated IFM with 24/48V LEDs for output modulesDS24A Isolated IFM with 24V LEDs for input modulesD120 120V LEDs for input and output modulesD120N Narrow IFM with 120V LEDsD120A 120V LEDs for input modulesDS120 Isolated IFM with 120V LEDs for output modulesDS120A Isolated IFM with 120V LEDs for input modulesD240 240V LEDs for output modulesDS240A Isolated IFM with 240V LEDs for input modulesD240A 240V LEDs for input modules

Fuses and Their IndicatorsBlank No fuse clipsF 5 x 20 mm fuse clipsF24 5 x 20 mm fuse clips with 24V blown fuse

indicators for output modulesF24A 5 x 20 mm fuse clips with 24V blown fuse

indicators for input modulesF120 5 x 20 mm fuse clips with 120V blown fuse

indicators for output modulesF120A 5 x 20 mm fuse clips with 120V blown fuse

indicators for input modulesF240 5 x 20 mm fuse clips with 240V blown fuse

indicators for output modulesFS Isolated IFM with 5 x 20 mm fuse clipsFS24 Isolated IFM with 5 x 20 mm fuse clips with

24V blown fuse indicators for output modules

FS24A Isolated IFM with 5 x 20 mm fuse clips with 24V blown fuse indicators for input modules

FS120 Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indicators for output modules

FS120A Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indication for input modules

FS240 Isolated IFM with 5 x 20 mm fuse clips with 240V blown fuse indication for output modules

No. of Cable Connector Pins20 20 pins40 40 pins

Digital Interface Modules

No. of Field-Side Wiring TerminalsBlank One per I/O connection2 Two per I/O connection3 Three per I/O connection4 Four per I/O connection

1492–IFM 20 F–F120–2

Bulletin No.

Publication 1492-TD008A-EN-P - March 2001

Page 14: Prog Controller Wiring Systems

14 Digital/Analog Programmable Controller Wiring Systems

Terms for Relay Master/Expander IFMs

Relay master and expander XIMs are available for Bulletin 1746, 1756, 1769, and 1771 digital output modules.Relay Master XIM Provides 8 or 16 relay outputs for a digital output module. Expander XIM In addition to the relay master XIM, an expander XIM provides eight additional outputs. There are three types of expander XIMs: eight-channel relays, eight-channel fusing, and eight-channel feed-through XIMs.

Relay Master/Expander XIMs Cat. No. Explanation for Digital I/O Modules

Important: The following XIM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired XIM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.

1492–XIM 20 24–2

Rating of Relay Coil or Blown Fuse Indicator24 24V relay coil120 120V relay coilF No relays or fusesF-F24 5 x 20 mm fuse clips with 24V blown fuse indicatorsF-F120 5 x 20 mm fuse clips with 120V blown fuse indicators

Relay Master and Expander Interface Modules

No. Cable Connector Pins20 20 pins (master only)40 40 pins (master only)Blank Expander module

No. Relays or Extra Terminals2 2 terminals per point8R 8 relays16R 16 relays

Bulletin No.

Publication 1492-TD008A-EN-P - March 2001

Page 15: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 15

IFM and XIM Cable Cat. No. Explanation for Digital I/O Modules

Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1746, 1756, and 1771 digital I/O module cables. All combinations of these fields make valid product cat. nos. Refer to selection tables for IFM/XIM compatibility and ordering.

The cables used for Relay Master/Expander XIMs are the same as those used for Digital I/O Modules (page 23) with the exception of the Cat. No. 1746-OA16 output module, which uses the 1492-CABLE*CR cable.

➊ To make sure the Bulletin 1746 SLC 500 digital I/O module is compatible with the IFM/XIM, refer to pages 25, 26, and 27.

➋ To make sure the Bulletin 1771 PLC digital I/O module is compatible with the IFM/XIM, refer to pages 40, 41, and 42.

➌ To make sure the Bulletin 1756 ControlLogix digital I/O module is compatible with the IFM/XIM, refer to pages 30, 31, and 32.

Cable TypeA, B, C, D, E, G, N, S

Pre-wired cables for 8-channel isolated and 16-channel digital Bulletin 1746 I/O modules ➊

CR Pre-wired cable for Cat. No. 1746-OA16 (XIM only)F, T Pre-wired cable for digital Bulletin 1771 I/O modules ➋

FF Pre-wired cable with fused wiring arm for 16-channel digital Bulletin 1771 output modules ➋

H Pre-wired cable for 32-channel digital Bulletin 1746 I/O modules ➊

J, K, L, M, R Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1771 I/O modules ➋

U, V, W, X Pre-wired cables for 8- and 16-channel digital Bulletin 1756 I/O modules ➌

Y, Z Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1756 I/O modules ➌

P Digital IFM-ready cable with 20 conductorsQ Digital IFM-ready cable with 40 conductorsN3 Digital I/O module-ready cable with 40-channel Cat. No. 1746-N3

cable connectorRTBB Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25B

terminal block (blue)RTBO Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25C

terminal block (orange)RTBR Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25R

terminal block (red)TBCH Digital I/O module-ready cable with 36-channel Cat. No. 1756-TBCH

removable terminal blockTBNH Digital I/O module-ready cable with 20-channel Cat. No. 1756-TBNH

removable terminal blockWA Digital I/O module-ready cable with Cat. No. 1771-WA

8-channelwiring armWD Digital I/O module-ready cable with Cat. No. 1771-WD 6-channel

wiring armWH Digital I/O module-ready cable with Cat. No. 1771-WH 16-channel

wiring armWHF Digital I/O module-ready cable with Cat. No. 1771-WHF 16-channel

fused wiring armWN Digital I/O module-ready cable with Cat. No. 1771-WN 32-channel

wiring arm

Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001…020

0.1…2.0 m (0.328…6.56 ft)0.1 m (0.328 ft) increments

Build-to-Order

020…100

2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments

100…990

10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

1492–CABLE 010 A

Digital Interface Cable

Bulletin No.

Publication 1492-TD008A-EN-P - March 2001

Page 16: Prog Controller Wiring Systems

16 Digital/Analog Programmable Controller Wiring Systems

IFM and XIM Cable Cat. No. Explanation for Digital I/O Modules, Continued

Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1769 and 1771 digital I/O module cables. All combinations of these fields make valid product cat. no. Refer to selection tables for IFM/XIM compatibility and ordering.

➊ To make sure the Bulletin 1771 PLC analog I/O module is compatible with the IFM, see pages 40 and 41.

Cable TypeA69, B69, C69, D69, E69, F69, G69

Pre-wired cables for 8- and 16-channel Bulletin 1769 digital I/O modules

RTN18 I/O-ready cable with Cat. No. 1746-RTBN18 terminal block

RTN10 I/O-ready cable with Cat. No. 1746-RTBN10 terminal block

R71 Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1771 I/O modules ➊

Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001-020 0.1…2.0 m (0.328…6.56 ft)

0.1 m (0.328 ft increments)Build-to-Order

020-100 2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments

100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

1492–CAB 010 A69

Digital Interface Cable

Bulletin No.

Publication 1492-TD008A-EN-P - March 2001

Page 17: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 17

Analog IFM Options and Features

Analog IFMs (AIFMs), similar to groups of terminal blocks, are available with either 15- or 25-pin D-shell connectors. The number of field-side wiring terminals varies with the type of module from three to five terminals per I/O channel. AIFMs are available as feed-through or fusible to customize the wiring system to your application.

All of the AIFMs have the following features:

UL Component Recognized (File E113724 Guide NRAQ2); UL recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2); CE Approved; Factory Mutual Listed (File J.I. 3000590) FM approved

Polarized D-shell connector (15- or 25-pin) for easy installation. Pre-wired cable has mating D-shell connector with slide-locking mechanism for secure connection.

Standard DIN #3 Rail mounting for quick installation.

Large rectangular write-on area acts as built-in group marking carrier for programmable controller rack, module group, and/or slot information.

Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.

High-density field-side wiring terminals allow more connections in less space and accommodate #22…12 AWG wire.

Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules.

Analog IFM

Publication 1492-TD008A-EN-P - March 2001

Page 18: Prog Controller Wiring Systems

18 Digital/Analog Programmable Controller Wiring Systems

Analog IFM Options and Features, Continued

Analog Feed-Through Modules

Feed-through AIFMs have three terminals per I/O channel to wire the I/O module connections and device shield. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the cable shield. Some feed-through AIFMs also have special features (refer to page 18).The Cat. No. 1492-AIFM4-3 AIFM, when used with Cat. Nos. 1771-OFE2 and -OFE3 controllers, provides selectable current limiting resistors. Simply flip a DIP switch to add the 250 ohms series impedance into the output circuit. As a troubleshooting aid, test point loops access the circuit on either side of the series resistor and can be used to measure output circuit voltage/current. The limiting resistors are configured on a per channel basis.The Cat. No. 1492-AIFM6TC-3 AIFM for the Cat. No. 1756-IT6I controller provides on-board cold junction compensation to allow thermocouples to be connected remotely while still correcting for temperature at the termination point. The combination thermistor and isothermal bar acquires temperature data at the AIFM for the thermocouple module to adjust the input value.The Cat. No. 1492-AIFM8-3 AIFM has eight extra terminals commoned together in a power bus that can be used for Module Common connections or power supply connections. The extra terminals and internal jumpering eliminate the need for some terminal blocks for power connections and jumper accessories.Below are examples of the field-side connections available on the feed-through AIFMs.

4-Wire Transmitter Input

Output

AIFM

Pre-wired Cable

Analog Input Module

Power Supply Transmitter

Channel 1+

Channel 1-

SHIELD

1+

1-

AIFM

Pre-wired Cable

Analog Output Module

LOAD

OUT 0

ANL COMC

SH

0

Publication 1492-TD008A-EN-P - March 2001

Page 19: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 19

Analog IFM Options and Features, Continued

Analog Fusible Modules

Fusible AIFMs are available for analog input modules. These AIFMs enable you to fuse the input device power source on the field-side. The field-side power source is distributed through individual on-board 5 x 20 mm fuse clips. The AIFMs have 24V DC blown fuse indicators to reduce the troubleshooting time needed to locate and replace a blown fuse. Standard fuse holders that reside in the AIFM are aided in the removal of the fuse with a fuse puller (fuses are not included). Isolation switch plugs or dummy fuses (refer to Accessories, page 200) are also available to isolate an input circuit after power is removed. In addition, once the circuit has been isolated and power restored, the input loop current can be measured in 2-wire transmitter applications.The fusible AIFMs have five terminals per input channel (except Cat. No. AIFM16-F-3, which has three terminals per channel) to wire the input module connections, device shield, and power connections for 2-, 3-, and 4-wire transmitters. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the cable shield. There are two separate power busses (416 terminals, depending on the AIFM) that can be used for +V and DC COM connections and/or Module Common. The extra terminals and internal connections eliminate additional terminal blocks and jumpers reducing spare parts inventory, saving panel space, and simplifying installation.All of the fusible AIFMs have on-board DIP switches to easily connect unused inputs to module common reducing wiring on the field-side. You no longer need extra jumper wires or comb-style jumpers to properly terminate unused inputs, as recommended on many Bulletin 1746, 1756, and 1771 analog input modules. Inputs are jumpered via DIP switch on a per-channel basis.The Cat. Nos. 1492-AIFM4I-F-5 and 1492-AIFM4C-F-5 AIFMs both have test point loops on either side of the fuse clips for easier access and connection of metering equipment. Metering equipment can also be attached to the fuse clips on other AIFMs for measuring input loop current.

Publication 1492-TD008A-EN-P - March 2001

Page 20: Prog Controller Wiring Systems

20 Digital/Analog Programmable Controller Wiring Systems

Analog IFM Options and Features, Continued

Analog Fusible Modules, Continued

Below are examples of the field-side connections for 2- and 4-wire transmitters available on the fusible AIFMs.

2-Wire Transmitter

4-Wire Transmitter

The Cat. No. 1492-AIFMQS AIFM is a specialized module for use with the Cat. No. 1746-QS synchronized axis module. The module has four input channels that match the input requirement of the 1746-QS, a matching output channel provided for each input channel, and power terminals that provide fused field-side device power. Extra terminals allow convenient connection for power and shield terminal connections. An example of the field-side connections is shown below.

AIFM

Pre-wired CableAnalog Input Module

Power Supply

Transmitter

+V

V1

1+

SHIELD

1-

VCOM

Channel 1+

Channel 1-

AIFM

Pre-wired Cable

Analog Input ModulePower Supply

Transmitter

+V

V1

1+

1-

SHIELD

VCOM

Channel 1+

Channel 1-

+INT 1

-INT 1

+ RET 1

-RET 1

+OUT 1

OUT COM

+ Interrogate 1

- Interrogate 1

+ Return 1

- Return 1

Drive Output 1

Drive Common

12

24

13

25

11

23

2

3

1

11

17

26

White/Blue

Blue/White

White/Orange

Orange/White

White/Green

Green/White

Sensor

Load

+INT 1

-INT 1

+ RET 1

-RET 1

+OUT 1

OUT COM

+ Interrogate 1

- Interrogate 1

+ Return 1

- Return 1

Drive Output 1

Drive Common

12

24

13

25

11

23

2

3

1

11

17

26

White/Blue

Blue/White

White/Orange

Orange/White

White/Green

Green/White

Sensor

Load

AIFMAnalog Input Module

Publication 1492-TD008A-EN-P - March 2001

Page 21: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 21

AIFM Cat. No. Explanation for Analog I/O Modules

Important: The following AIFM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.

No. Analog I/O Channels4 4 channels: input, output,

or 2 input/output combination

4C 4 channels: 2 input/2 output combination

4I 4 input channels6S 6 isolated input or output

channels6TC 6 thermocouple input

channels8 8 input or output channels16 16 input channelsPI 8 input/2 output channels

1492–AIFM 16–F–5

Input Fuse Clips and Blown Fuse IndicatorsBlank No fuse clipsF 5 x 20 mm fuse clips with

24V DC blown fuse indicators for output modules

No. Field-Side Wiring Terminals3 3 per I/O channel5 5 per input channelAnalog Interface Modules

Bulletin No.

Publication 1492-TD008A-EN-P - March 2001

Page 22: Prog Controller Wiring Systems

22 Digital/Analog Programmable Controller Wiring Systems

Pre-Wired Cable Cat. No. Explanation for Bulletins 1746, 1756, and 1771 Analog I/O Modules

Important: The following analog cable cat. no. breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.

Pre-Wired Cable Cat. No. Explanation for Bulletin 1746 and 1769 Analog I/O Modules

Important: The following analog cable cat. no. breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.

A-Cable TypeA, B, C, D,L, Q

Pre-wired cables for Bulletin 1746 analog and RTD I/O modules.

E, F, G, H, J Pre-wired cables for Bulletin 1771 analog and RTD I/O modules.

TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z

Pre-wired cables for Bulletin 1756 analog, RTD, and thermocouple I/O modules.

M Pre-wired cables for Bulletin 1757 pulse input I/O modules

Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001-020 0.1…2.0 m (0.328…6.56 ft)

0.1 m (0.328 ft increments)Build-to-Order

020-100 2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments

100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

1492–ACABLE 050 A

Analog Interface Cables

Bulletin No.

Cable TypeA46 Pre-wired cables for Bulletin 1746-NI16I and

-NI16V analog modules. AA69, AB69, BA69, BB69, BC69, BD69

Pre-wired cables for Bulletin 1769 analog I/O modules.

Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001-020 0.1…2.0 m (0.328…6.56 ft)

0.1 m (0.328 ft increments)Build-to-Order

020-100 2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments

100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

1492–ACAB 005 A46

Analog Interface Cables

Bulletin No.

Publication 1492-TD008A-EN-P - March 2001

Page 23: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 23

Ordering Digital and Analog Wiring Systems

To order the proper IFM/XIM/AIFM pre-wired cable:1. Determine I/O platform (e.g., Bulletin 1746, 1756, 1769, 1771) and the

cat. no. of the I/O module being specified. 2. Determine whether you require field-side LEDs, fusing for over-current

protection, or relays (check voltage ratings for LEDs, fuse blown indication, relay, and coil).

3. Determine your field-side wiring requirements. Are extra terminals needed?

4. Determine desired cable length (0.5 m, 1.0 m, 2.5 m, 5.0 m, or build-to-order) based on wiring needs from I/O module to IFM/XIM/AIFM.

5. Refer to selection tables as follows:

Ordering Digital IFM-Ready Cables and IFMs/XIMs

For pinout and wiring information, refer to IFM-Ready Cable Specifications on page 129 and the selection table on page 44.

Ordering Digital I/O Module-Ready Cables

To order the proper I/O module-ready cable, the following information is required:

• Type of connector needed for the I/O module(s) (cat. no. of the wiring arm or removable terminal block).

• Code for the desired cable length: 010 = 1.0 m 025 = 2.5 m 050 = 5.0 m Build-to-order length

Selection Table Quick Reference

Platform Page No.

Bulletin 1746 Digital 25

Bulletin 1746 Analog 28

Bulletin 1756 Digital 30

Bulletin 1756 Analog 33

Bulletin 1769 Digital 36

Bulletin 1769 Analog 37

Bulletin 1771 Digital 40

Bulletin 1771 Analog 43

Publication 1492-TD008A-EN-P - March 2001

Page 24: Prog Controller Wiring Systems

24 Digital/Analog Programmable Controller Wiring Systems

Selection Tables Using Bulletin 1746 Selection Tables to Make Valid Cat. Nos.

Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are

compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.

4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CABLE➊ (for digital cables) or

1492-ACABLE➊ (for analog cables). See footnote ➊ on pages 27 and 28.

Publication 1492-TD008A-EN-P - March 2001

Page 25: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 25

Selection Tables, Continued

Bulletin 1746 SLC 500 IFMs and Cables

➊ One expander is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to attach it to the master.

Bulletin 1746 Digital 16-Point and 8-Point Isolated I/O Modules

Type of IFM

Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1746-…

IA16

IB16

IC16

IG16

IH16

IM16

IN16

ITB

16

ITV1

6

IV16

OA

16

OB

16

OB

16E

OB

P16

OG

16

OV1

6

OVP

16

OW

16

OX8

Feed-through

Standard 1492-IFM20F A B B E B A B B B B C E E E E E E D D

Narrow standard 1492-IFM20FN A B B E B — B B B B G E E E E E E N N

Extra terminals 1492-IFM20F-2 A B B E B A B B B B C E E E E E E D —

3-wire sensor type input devices 1492-IFM20F-3 A B B E B — B B B B — — — — — — — — —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM20D24 — B — — — — B B B B — E E E — E E D —

Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — B — — — — B B B B — E E E — — — N —

Standard with 120V AC/DC LEDs 1492-IFM20D120 A — — — B — — — — — C — — — — — — D —

Narrow standard with 120V AC LEDs 1492-IFM20D120N A — — — — — — — — — G — — — — — — N —

24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — — — — — — — E E E — E E D —

24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — B — — — — B B B B — — — — — — — — —

120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — — — C — — — — — — D —

120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 A — — — — — — — — — — — — — — — — —

3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — B — — — — B B B B — — — — — — — —

Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM20DS24-4 — — — — — — — — — — — — — — — — — — S

Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — — — — — — — — — — — — — — — S

240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — — — C — — — — — — D —

240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — — — A — — — — — — — — — — — — —

Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — — — — — — C E E E — E E D —

Extra terminals with 24V AC/DC B/F indicators 1492-IFM20F-F24-2 — — — — — — — — — — — E E E — E E D —

Extra terminals with 120V AC B/F indicators 1492-IFM20F-F120-2 — — — — — — — — — — C — — — — — — D —

Extra terminals with 240V AC B/F indicators 1492-IFM20F-F240-2 — — — — — — — — — — C — — — — — — D —

Extra terminals with 24V AC/DC B/F indicators 1492-IFM20F-F24A-2 — B — — — — B B — — — — — — — E E — —

Extra terminals with 120V AC/DC B/F indicators 1492-IFM20F-F120A-2 A — — — B — — — — — — — — — — — — — —

Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — — — — — — — — — — — — — — — S

Isolated with extra terminals and 24V AC/DC blown fuse indicators

1492-IFM20F-FS24-2 — — — — — — — — — — — — — — — — — — S

Isolated with four terminals/input and 24V AC/DC blown fuse indicators

1492-IFM20F-FS24A-4 — — — — — — — — — — — — — — — — — — —

Isolated with extra terminals and 120V AC/DC blown fuse indicators

1492-IFM20F-FS120-2 — — — — — — — — — — — — — — — — — — S

Isolated with four terminals/output and 120V AC/DC blown fuse indicators

1492-IFM20F-FS120-4 — — — — — — — — — — — — — — — — — — S

Isolated with four terminals/input and 120V AC/DC blown fuse indicators

1492-IFM20F-FS120A-4 — — — — — — — — — — — — — — — — — — —

Isolated with four terminals/output and 240V AC/DC blown fuse indicators

1492-IFM20F-FS240-4 — — — — — — — — — — — — — — — — — — S

Relay Master

20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — — — — — — — E E E — — — — —

20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — — — CR — — — — — — — —

Relay Expander

Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — — ➊ ➊ ➊ — — — — —

Expander with eight (8)120V AC relays 1492-XIM120-8R — — — — — — — — — — ➊ — — — — — — — —

Fusible Expander

8-ch. expander with 24V DC B/F indicators 1492-XIMF-F24-2 — — — — — — — — — — — ➊ ➊ ➊ — — — — —

8-ch. expander with 120V AC B/F indicators 1492-XIMF-F120-2 — — — — — — — — — — ➊ — — — — — — — —

Feed-through Expander

Expander with eight feed-through channels 1492-XIMF-2 — — — — — — — — — — ➊ ➊ ➊ ➊ — — — — —

Publication 1492-TD008A-EN-P - March 2001

Page 26: Prog Controller Wiring Systems

26 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1746 SLC 500 IFMs and Cables, Continued

➊ Two or three expanders can be connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.

Bulletin 1746 Digital 32-Point I/O Modules

Type of IFM Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1746-…

IB32

IV32

OB32

OB32

E

OV32

Feed-through Standard 1492-IFM40F H H H H HExtra terminals 1492-IFM40F-2 H H H H H3-wire sensor type input devices 1492-IFM40F-3 H H — — —

LED Indicating Standard with 24V AC/DC LEDs 1492-IFM40D24 H H H H H24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — H H H24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 H H — — —120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — — — —120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 H H — — —Isolated with 24/48V AC/DC LEDs and four terminals/output 1492-IFM40DS24-4 — — — — —Isolated with 24V AC/DC LEDs and four terminals/input 1492-IFM40DS24A-4 — — — — —Isolated with 120V AC LEDs and four terminals/output 1492-IFM40DS120-4 — — — — —Isolated with 120V AC LEDs and four terminals/input 1492-IFM40DS120A-4 — — — — —Isolated with 240V AC LEDs and four terminals/input 1492-IFM40DS240A-4 — — — — —

Fusible Extra terminals for outputs 1492-IFM40F-F-2 — — H H HExtra terminals with 24V AC/DC blown fuse indicators 1492-IFM40F-F24-2 — — H H HExtra terminals with 120V AC blown fuse indicators 1492-IFM40F-F120-2 — — — — —Isolated with extra terminals for outputs 1492-IFM40F-FS-2 — — — — —Isolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM40F-FS24-2 — — — — —Isolated with 24V AC/DC blown fuse indicators and four terminals/output

1492-IFM40F-FS24-4 — — — — —

Isolated with extra terminals and 120V AC/DC blown fuse indicators 1492-IFM40F-FS120-2 — — — — —Isolated with 120V AC/DC blown fuse indicators and four terminals/output

1492-IFM40F-FS120-4 — — — — —

Isolated with 240V AC/DC blown fuse indicators and four terminals/output

1492-IFM40F-FS240-4 — — — — —

Isolated with 24V AC/DC blown fuse indicators and four terminals/input 1492-IFM40F-FS24A-4 — — — — —Isolated with 120V AC/DC blown fuse indicators and four terminals/input

1492-IFM40F-FS120A-4 — — — — —

Relay Master 40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — H H —40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R — — H H —

Relay Expander Expander with eight (8) 24V DC relays 1492-XIM24-8R — — ➊ ➊ —

Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — —Fusible Expander 8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — ➊ ➊ —

8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — —Feed through Expander Expander with eight feed-through channels 1492-XIMF-2 — — ➊ ➊ —

Publication 1492-TD008A-EN-P - March 2001

Page 27: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 27

Selection Tables, Continued

Bulletin 1746 SLC 500 IFMs and Cables, Continued

These pre-wired cables have a pre-wired removable terminal block (RTB) on one end to connect to the front of a Bulletin 1746 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables.

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005N is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1746-OW16 I/O module. Build-to-order lengths are also available.

The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1746 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.

➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050RTBR is for a 5.0 m cable with a pre-wired Cat. No. 1746-RT25R RTB on one end.

Note: The following I/O Modules do not have RTBs: 1746-IA4, 1746-IA8, 1746-IB8, 1746-IM4, 1746-IM8, 1746-IV8, 1746-OA8, 1746-OB8.

Pre-Wired Cables for Bulletin 1746 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1746I/O Module Cat. No.

1492-CABLE➊ A 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-IA16, -IM161492-CABLE➊ B 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-IB16, -IH16, -IN16, -ITB16, -ITV161492-CABLE➊ C 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OA161492-CABLE➊ CR 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OA161492-CABLE➊ D 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OW16, -OX81492-CABLE➊ E 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-IG16, -OB16, -OB16E, -OBP16, -OG16, -OV16, -OVP161492-CABLE➊ G 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OA161492-CABLE➊ H 0.5, 1.0, 2.5, 5.0 m Yes 40 1746-IB32, -IV32, -OB32, -OB32E, -OV321492-CABLE➊ N 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OW16, -OX81492-CABLE➊ S 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OX8

I/O Module-Ready Cables for Bulletin 1746 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1746I/O Module Cat. No.

1492-CABLE➋ N3 1.0, 2.5, 5.0 m Yes 40 1746-IB32, -IV32, -OB32, -OV32, -OB32E1492-CABLE➋ RTBB 1.0, 2.5, 5.0 m Yes 20 1746-IB16, -IC16, -IG16, -IH16, -IN16, -ITB16, -ITV16,

-IV16, -OB16, -OB16E, -OBP8, -OBP16, -OG16, -OV16, -OVP16

1492-CABLE➋ RTBO 1.0, 2.5, 5.0 m Yes 20 1746-OW16, -OX81492-CABLE➋ RTBR 1.0, 2.5, 5.0 m Yes 20 1746-IA16, -OA16, -OAP12, -IM16

Publication 1492-TD008A-EN-P - March 2001

Page 28: Prog Controller Wiring Systems

28 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1746 SLC 500 AIFMs and Cables

These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1746 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. To use this table, you must first have selected an IFM from the preceding table.

➊ To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM4I-F-5 IFM to a Cat. No. 1746-NI4 I/O module.

Bulletin 1746 Analog I/O Modules

Type of AIFM Description of AIFM AIFM Cat. No. I/O Module Cat. No. 1746-…

FIO4

I

FIO4

V

NI4

NI8

NIO

4I

NIO

4V

NO4

I

NO4

V

NR4

QS NI1

6I

NI1

6V

Feed-through 4-channel with 3 terminals/channel 1492-AIFM4-3 L L A — L L B B — — — —6-channel isolated with 3…4 terminals/channel

1492-AIFM6S-3 — — — — — — — — D — — —

8-channel with 3 terminals/channel 1492-AIFM8-3 — — C — — — — — — A46 A46Thermocouple 6-channel with 3 terminals/channel 1492-AIFM6TC-3 — — — — — — — — — — — —Fusible 2-channel with 24V blown fuse

indicators, test points, 5 terminals/input, 3 terminals/output

1492-AIFM4C-F-5 L L — — L L — — — — — —

4-channel with 24V blown fuse indicators, test points, 5 terminals/input

1492-AIFM4I-F-5 — — A — — — — — — — — —

8-channel with 24V blown fuse indicators, 5 terminals/channel

1492-AIFM8-F-5 — — — C — — — — — — — —

16-channel with 24V blown fuse indicators, 3 terminals/channel

1492-AIFM16-F-3 — — — — — — — — — — A46 A46

16-channel with 24V blown fuse indicators, 5 terminals/channel

1492-AIFM16-F-5 — — — — — — — — — — — —

4-input/4-output channel with 8 fuses and 24V blown fuse indicators

1492-AIFMQS — — — — — — — — — Q — —

Pre-Wired Cables for Bulletin 1746 Analog I/O Modules

Cable Cat. No. Standard Cable Lengths (m) Build-to-Order Available AIFM Connector Mating 1746 I/O Module Cat. No.1492-ACABLE➊ A 0.5, 1.0, 2.5, 5.0 Yes 15-pin D-shell 1746-NI41492-ACABLE➊ B 0.5, 1.0, 2.5, 5.0 Yes 15-pin D-shell 1746-NO4I, -NO4V1492-ACABLE➊ C 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-NI81492-ACABLE➊ D 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-NR41492-ACABLE➊ L 0.5, 1.0, 2.5, 5.0 Yes 15-pin D-shell 1746-NIO4I, -NIO4V, -FIOVI, -FIO4V1492-ACABLE➊ Q 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-QS1492-ACAB➊ A46 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-NI16I, -NI16V

Publication 1492-TD008A-EN-P - March 2001

Page 29: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 29

Selection Tables, Continued

Using Bulletin 1756 Selection Tables to Make Valid Cat. Nos.

Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are

compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.

4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CABLE➊ (for digital cables) or

1492-ACABLE➊ (for analog cables). See footnote ➊ on pages 32 and 34.

Publication 1492-TD008A-EN-P - March 2001

Page 30: Prog Controller Wiring Systems

30 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1756 ControlLogix IFMs and Cables

➊ One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to connect it to the master.

Bulletin 1756 Digital 8-Point and 16-Point I/O Modules

Type of IFM

Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1756-…

IA8D

IA16

IB16

IC16

IN16

OA8

OA8D

OA8E

OA16

OB8

OB16

E

OC8

ON8

Feed-through

Standard 1492-IFM20F U X X X X U U U X U X U UNarrow standard 1492-IFM20FN U X X X X U U U X U X U UExtra terminals 1492-IFM20F-2 U X X X X U U U X U X U U3-wire sensor type input devices 1492-IFM20F-3 — X X X X — — — — — — — —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM20D24 — — X — X — — — — — X — —Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — — X — X — — — — — X — —Standard with 120V AC/DC LEDs 1492-IFM20D120 U X — — — — — — — — — — —Narrow standard with 120V AC LEDs 1492-IFM20D120N U X — — — — — — X — — — —24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — — — — — — X — —24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — — X — X — — — — — — — —120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — X — — — —120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 U X — — — — — — — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — — X — X — — — — — — — —Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM20DS24-4 — — — — — — — — — W — W WIsolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — — W V V — — — — —240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — — — — — —240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — — — — — — — — — — —

Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — — — — X — X — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24-2 — — — — — — — — — — X — —Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120-2 — — — — — — — — X — — — —Extra terminals with 240V AC blown fuse indicators 1492-IFM20F-F240-2 — — — — — — — — X — — — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24A-2 — — X — X — — — — — — — —Extra terminals with 120V AC/DC blown fuse indicators 1492-IFM20F-F120A-2 — X — — — — — — — — — — —Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — — W V V — W — W WIsolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24-2 — — — — — — — — — W — W WIsolated with 4 terminals/input and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24A-4 — — — — — — — — — — — — —Isolated with extra terminals and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-2 — — — — — W V V — — — — —Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-4 — — — — — W V V — — — — —Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120A-4 U — — — — — — — — — — — —Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 1492-IFM20F-FS240-4 — — — — — W — — — — — — —

Relay Master

20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — — — — — — X — —20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — X — — — —

Relay Expander

Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — ➊ — —Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — ➊ — — — —

Fusible Expander

Expander with eight (8) 24V channels with blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — ➊ — —Expander with eight (8) 120V channels with blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — ➊ — — — —

Feed-through Expander

Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — — — ➊ — ➊ — —

Publication 1492-TD008A-EN-P - March 2001

Page 31: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 31

Selection Tables, Continued

Bulletin 1756 ControlLogix IFMs and Cables, Continued

➊ Two or three expander modules are connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.

Bulletin 1756 Digital 16-Point Isolated and 32-Point I/O Modules

Type of IFM

Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1756-…

IA16

I

IB16

D

IB16

I

IB32

IH16

I

IM16

I

OA16

I

OB8E

I

OB16

D

OB16

I

OB32

OH8I

OW16

I

OX8I

Feed-through

Standard 1492-IFM40F Y Y Y Z Y — Y Y Y Y Z Y Y Y

Extra terminals 1492-IFM40F-2 — Y — Z — — — — Y — Z — — —

3-wire sensor type input devices 1492-IFM40F-3 — — — Z — — — — — — — — — —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM40D24 — — — Z — — — — — — Z — — —

24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — — — — — — — — — Z — — —

24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 — — — Z — — — — — — — — — —

120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — — — — — — — — — — — — —

120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 — — — — — — — — — — — — — —

3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 — — — Z — — — — — — — — — —

Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM40DS24-4 — — — — — — — Y Y Y — — Y Y

Isolated with 24V AC/DC LEDs and 4 terminals/input 1492-IFM40DS24A-4 — Y Y — — — — — — — — — — —

Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM40DS120-4 — — — — — — Y — — — — — Y Y

Isolated with 120V AC LEDs and 4 terminals/input 1492-IFM40DS120A-4 Y — — — — — — — — — — — — —

Isolated with 240V AC LEDs and 4 terminals/input 1492-IFM40DS240A-4 — — — — — Y — — — — — — — —

Fusible Extra terminals for outputs 1492-IFM40F-F-2 — — — — — — — — — — Z — — —

Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM40F-F24-2 — — — — — — — — — — Z — — —

Extra terminals with 120V AC blown fuse indicators 1492-IFM40F-F120-2 — — — — — — — — — — — — — —

Isolated with extra terminals for outputs 1492-IFM40F-FS-2 — — — — — — Y Y Y Y — Y Y Y

Isolated with extra terminals and 24V AC/DC blown fuse indicators

1492-IFM40F-FS24-2 — — — — — — — Y Y Y — — Y Y

Isolated with 24V AC/DC blown fuse indicators and 4 terminals/output

1492-IFM40F-FS24-4 — — — — — — — Y Y Y — — Y Y

Isolated with extra terminals and 120V blown fuse indicators 1492-IFM40F-FS120-2 — — — — — — Y — — — — Y Y Y

Isolated with 120V AC/DC blown fuse indicators and 4 terminals/output

1492-IFM40F-FS120-4 — — — — — — Y — — — — — Y Y

Isolated with 240V AC/DC blown fuse indicators and 4 terminals/output

1492-IFM40F-FS240-4 — — — — — — Y — — — — — Y Y

Isolated with 24V AC/DC blown fuse indicators and 4 terminals/input

1492-IFM40F-FS24A-4 — Y Y — — — — — — — — — — —

Isolated with 120V AC/DC blown fuse indicators and 4 terminals/input

1492-IFM40F-FS120A-4 Y — — — Y — — — — — — — — —

Relay Master

40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — — — — — — — — — Z — — —

40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R — — — — — — — — — — Z — — —

Relay Expander

Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — ➊ — — —

Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — — — — — — —

Fusible Expander

8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — ➊ — — —

8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — — — — — — —

Feed-through Expander

Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — — — — — ➊ — — —

Publication 1492-TD008A-EN-P - March 2001

Page 32: Prog Controller Wiring Systems

32 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1756 ControlLogix IFMs and Cables, Continued

These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables.

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM40F IFM to a Cat. No. 1756-IA16I I/O module.

The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1756 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.

➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050TBNH is for a 5.0 m cable with a pre-wired Cat. No. 1756-TBNH RTB on one end.

Pre-Wired Cables for Bulletin 1756 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1756I/O Module Cat. No.

1492-CABLE➊ U 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-IA8D, -OA8, -OA8D, -OA8E, -OB8, -OC8, -ON8

1492-CABLE➊ V 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-OA8D, -OA8E

1492-CABLE➊ W 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-OA8, -OBE, -OC8, -ON8

1492-CABLE➊ X 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-IA16, -IB16, -IC16, -IN16, -OA16, -OB16E

1492-CABLE➊ Y 0.5, 1.0, 2.5, 5.0 m Yes 40 1756-IA16I, -IB16D, -IB16I, -IH16, -OA16I, -OB8EI, -OB16D, -OB16I, -OH8I, -OW16I, -OX8I

1492-CABLE➊ Z 0.5, 1.0, 2.5, 5.0 m Yes 40 1756-IB32, -OB32

I/O Module-Ready Cables for Bulletin 1756 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1756I/O Module Cat. No.

1492-CABLE➋ TBNH 1.0, 2.5, 5.0 m Yes 20 1756-IA8D, -IA16, -IB16, -IC16, -IN16, -OA8, -OA8D, -OA8E, -OA16, -OB8, -OB16E, -OC8, -ON8

1492-CABLE➋ TBCH 1.0, 2.5, 5.0 m Yes 40 1756-IA16I, -IB16D, -IB16I, -IB32, -IF16, -IH16I, -IM16I, -OA16I, -OB8EI, -OB16D, -OB16I, -OB32, -OH8I, -OW16I, -OX8I

Publication 1492-TD008A-EN-P - March 2001

Page 33: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 33

Selection Tables, Continued

Bulletin 1756 ControlLogix AIFMs and Cables

➊ Some analog I/O modules can be operated in up to four modes (current/voltage, single-ended/differential) based on connections. In all cases, each channel is factory-configured for the same mode. However, you can field configure any channel for another mode.

Bulletin 1756 Analog I/O Module ➊

Type of AIFM Description of AIFM

AIFM Cat. No. I/O Module

Cat. No.1756-…

Cat. No.1757-…

IF6I

(Cur

rent

)

IF6I

(Vol

tage

)

IF8

(Sgl

-End

Vol

t)

IF8

(Sgl

-End

Crt)

IF8

(Diff

Vol

tage

)

IF8

(Diff

Cur

rent

)

IF16

(Sgl

-End

Vol

t)

IF16

(Sgl

-End

Crt

)

IF16

(Diff

Vol

tage

)

IF16

(Diff

cur

rent

)

IR6I

IT6I

OF4

(Vol

tage

)

OF4

(Cur

rent

)

OF6C

I

OF6V

I

OF8

(Vol

tage

)

OF8

(Cur

rent

)

PIM

Feed-through 4-channel with 3 terminals/channel

1492-AIFM4-3 — — — — — — — — — — — — VA VB — — — — —

6-channel isolated with 3…4 terminals/channel

1492-AIFM6S-3 X Y — — — — — — — — Z — — — Y Y — —

8-channel with 3 terminals/channel

1492-AIFM8-3 — — TA TB TC TD UA UB UC UD — — — — — — WA WB —

Thermocouple 6-channel with 3 terminals/channel

1492-AIFM6TC-3 — — — — — — — — — — — Y — — — — — — —

Fusible 8-channel with 5 terminals/channel

1492-AIFM8-F-5 — — TA TB TC TD — — UC UD — — — — — — — — —

16-channel with 3 terminals/channel

1492-AIFM16-F-3 — — — — — — UA UB UC UD — — — — — — — — —

16-channel with 5 terminals/channel

1492-AIFM16-F-5 — — — — — — UA UB UC UD — — — — — — — — —

8 input/2 output channels

1492-AIFMPI — — — — — — — — — — — — — — — — — — M

Publication 1492-TD008A-EN-P - March 2001

Page 34: Prog Controller Wiring Systems

34 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1756 ControlLogix AIFMs and Cables, Continued

These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 analog I/O module and a D-shell connector on the other end to plug into a 20- or 40-terminal AIFM. You must first select the AIFM from the preceding selection table.

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM6TC-3 analog IFM to a Cat. No. 1756-IT6I I/O module.

Pre-Wired Cables for 1756 Analog I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

AIFMConnector

Mating 1756I/O Module Cat. No.

1492-ACABLE➊ M 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1757-PIM

1492-ACABLE➊ X 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Current

1492-ACABLE➊ Y 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Voltage, -IT6I, -OF6CI, -OF6VI

1492-ACABLE➊ Z 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IR16

1492-ACABLE➊ TA 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Single-Ended Voltage

1492-ACABLE➊ TB 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Single-Ended Current

1492-ACABLE➊ TC 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Differential Voltage

1492-ACABLE➊ TD 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Differential Current

1492-ACABLE➊ UA 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Single-Ended Voltage

1492-ACABLE➊ UB 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Single-Ended Current

1492-ACABLE➊ UC 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Differential Voltage

1492-ACABLE➊ UD 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Differential Current

1492-ACABLE➊ VA 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1756-OF4 Voltage

1492-ACABLE➊ VB 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1756-OF4 Current

1492-ACABLE➊ WA 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-OF8 Voltage

1492-ACABLE➊ WB 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-OF8 Current

Publication 1492-TD008A-EN-P - March 2001

Page 35: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 35

Selection Tables, Continued

Using Bulletin 1769 Selection Tables to Make Valid Cat. Nos.

Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are

compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.

4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CAB➊ (for digital cables) or

1492-ACAB➊ (for analog cables). See footnote ➊ on pages 37 and 38.

Publication 1492-TD008A-EN-P - March 2001

Page 36: Prog Controller Wiring Systems

36 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables

➊ Sink mode only.➋ One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included

with each expander to connect it to the master.

Bulletin 1769 Digital I/O Modules

Type of IFM Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1769-…

IA8I

IA16

IQ16

IM12

OA8

OB16

OV16

OW8

OW8I

Feed-through Standard 1492-IFM20F F69 A69 B69 G69 C69 E69 E69 C69 D69Narrow standard 1492-IFM20FN F69 A69 B69 — C69 E69 E69 C69 —Extra terminals 1492-IFM20F-2 — A69 B69 G69 C69 E69 E69 C69 —3-wire sensor type input devices 1492-IFM20F-3 — A69 B69 — — — — — —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM20D24 — — B69 — — E69 E69 — —Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — — B69 — — E69 — — —Standard with 120V AC/DC LEDs 1492-IFM20D120 — A69 — — — — — — —Narrow standard with 120V AC LEDs 1492-IFM20D120N — A69 — — — — — — —24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — E69 E69 — —24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — — B69 — — — — — —120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — —120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 — A69 — — — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — — B69 — — — — — —Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM20DS24-4 — — — — — — — C69 D69Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — C69 — — C69 D69240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — —240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — G69 — — — — —

Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — E69 E69 — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24-2 — — — — — E69 E69 — —Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120-2 — — — — — — — — —Extra terminals with 240V AC blown fuse indicators 1492-IFM20F-F240-2 — — — — — — — — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24A-2 — — B69 ➊ — — — E69 — —Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120A-2 — A69 — — — — — — —Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — C69 — C69 D69Isolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24-2 — — — — — — — C69 D69Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24A-4 — — — — — — — — —Isolated with extra terminals and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-2 — — — — C69 — — C69 D69Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-4 — — — — C69 — — C69 D69Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120A-4 — — — — — — — — —Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 1492-IFM20F-FS240-4 — — — — — — — — D69

Relay Master

20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — E69 — — —20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — —

Relay Expander

Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — ➋ — — —Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — —

Fusible Expander

8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — ➋ — — —8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — —

Feed-through Expander

Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — ➋ — — —

Publication 1492-TD008A-EN-P - March 2001

Page 37: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 37

Selection Tables, Continued

Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables, Continued

These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 digital I/O module and a connector on the other end to plug into a 20-terminal IFM/XIM. You must first select the IFM/XIM from the preceding selection table.

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CAB005E69 is for a 0.5 m cable that can be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1769-OB16 I/O module.

The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1769 I/O module and 20 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.

➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CAB050RTN10 is for a 5.0 m cable with a wired Cat. No. 1746-RTBN10 on one end.

Pre-Wired Cables for Bulletin 1769 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1746I/O Module Cat. No.

1492-CAB➊ A69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IA161492-CAB➊ B69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IQ161492-CAB➊ C69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OA8, -OW81492-CAB➊ D69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OW8I1492-CAB➊ E69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OB16, -OV161492-CAB➊ F69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IA8I1492-CAB➊ G69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IM12

I/O Module-Ready Cables for Bulletin 1769 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1746I/O Module Cat. No.

1492-CAB➋ RTN10 1.0, 2.5, 5.0 m Yes 10 1769-OA8, -OW81492-CAB➋ RTN18 1.0, 2.5, 5.0 m Yes 18 1769-IA8I, -IA16, -IQ16, -OB16, -OV16, -OW8I, -IM12

Publication 1492-TD008A-EN-P - March 2001

Page 38: Prog Controller Wiring Systems

38 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 AIFMs and Cables

These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 analog I/O module and a connector on the other end to plug into a 20-terminal AIFM. You must first select the AIFM from the preceding selection table.

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACAB005➋ is for a 0.5 m cable.

IFMs for Bulletin 1769 Analog I/O Modules

AIFM Cat. No. I/O Module Cat. No. 1769-… OF2

(Voltage) OF2

(Current)IF4

(Single-Ended Voltage)

IF4(Single-Ended

Current)

IF4(Differential

Voltage)

IF4(Differential

Current)1492-AIFM4-3 AA69 AB69 BA69 BB69 BC69 BD691492-AIFM6S-3 — — — — — —1492-AIFM6TC-3 — — — — — —1492-AIFM8-3 — — — — — —1492-AIFM4I-F-5 — — — — — —1492-AIFM4C-F-5 — — — — — —1492-AIFM8-F-5 — — — — — —1492-AIFM16-F-3 — — — — — —1492-AIFM16-F-5 — — — — — —1492-AIFMQS — — — — — —

Pre-Wired Cables for Bulletin 1769 Analog I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

AIFMConnector

Mating 1769I/O Module Cat. No.

1492-ACAB➊ AA69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-OF2 Voltage1492-ACAB➊ AB69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-OF2 Current1492-ACAB➊ BA69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Single-Ended Voltage1492-ACAB➊ BB69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Single-Ended Current1492-ACAB➊ BC69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Differential Voltage1492-ACAB➊ BD69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Differential Current

Publication 1492-TD008A-EN-P - March 2001

Page 39: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 39

Selection Tables, Continued

Using Bulletin 1771 Selection Tables to Make Valid Cat. Nos.

Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are

compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.

4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CABLE➊ (for digital cables) or

1492-ACABLE➊ (for analog cables). See footnote ➊ on pages 42 and 43.

Publication 1492-TD008A-EN-P - March 2001

Page 40: Prog Controller Wiring Systems

40 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1771 PLC-5 IFMs and Cables

➊ Either F or FF.➋ One expander is connected to a master to provide a total of 16 outputs. An extender cable is included with each

expander to connect it to the master.

IFMs for Bulletin 1771 Digital 8-Point and 16-Point I/O Modules

Type of IFM

Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1771-…

IA IA2

IAD

IB IBD

ICD

IGD

IH IN IND

IT OA

D

OB

D

OG

D

OM

D

ON

D

IMD

Feed-through

Standard 1492-IFM20F — — F — F F F — — F — ➊ ➊ F F ➊ F

Narrow standard 1492-IFM20FN — — F — F F F — — F — ➊ ➊ F — ➊ —

Extra terminals 1492-IFM20F-2 — — F — F F F — — F — ➊ ➊ F F ➊ F

3-wire sensor type input devices 1492-IFM20F-3 — — F — F F F — — F — — — — — — —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM20D24 — — — — F F — — — F — ➊ ➊ — — ➊ —

Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — — — — F F — — — F — ➊ ➊ — — ➊ —

Standard with 120V AC/DC LEDs 1492-IFM20D120 — — F — — — — — — — — — — — — — —

Narrow standard with 120V AC LEDs 1492-IFM20D120N — — F — — — — — — — — ➊ — — — — —

24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — — — — — — — ➊ ➊ — — ➊ —

24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — — — — F F — — — F — — — — — — —

120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — — — — ➊ — — — — —

120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 — — F — — — — — — — — — — — — — —

3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — — — — F F — — — — — — — — — — —

Isolated with 24/48V AC/DC LEDs and 4 terminals/output

1492-IFM20DS24-4 — — — — — — — — — — — — — — — — —

Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — — — — — — — — — — — — — —

240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — — — — — — — F — —

240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — — — — — — — — — — — — — — F

Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — — — — — — — F F — — F —

Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24-2 — — — — — — — — — — — F F — — F —

Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120-2 — — — — — — — — — — — F — — — — —

Extra terminals with 240V AC blown fuse indicators 1492-IFM20F-F240-2 — — — — — — — — — — — — — — F — —

Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24A-2 — — — — F F — — — F — — — — — — —

Extra terminals with 120V AC/DC blown fuse indicators 1492-IFM20F-F120A-2 — — F — — — — — — — — — — — — — —

Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — — — — — — — — — — — — — —

Isolated with extra terminals and 24V AC/DC blown fuse indicators

1492-IFM20F-FS24-2 — — — — — — — — — — — — — — — — —

Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators

1492-IFM20F-FS24A-4 — — — T — — — T T — T — — — — — —

Isolated with extra terminals and 120V AC/DC blown fuse indicators

1492-IFM20F-FS120-2 — — — — — — — — — — — — — — — — —

Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators

1492-IFM20F-FS120-4 — — — — — — — — — — — — — — — — —

Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators

1492-IFM20F-FS120A-4 T T — — — — — — — — — — — — — — —

Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators

1492-IFM20F-FS240-4 — — — — — — — — — — — — — — — — —

Relay Master

20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — — — — — — — — ➊ — — — —

20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — — — — ➊ — — — — —

Relay Expander

Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — — — ➋ — — — —

Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — — — — ➋ — — — — —

Fusible Expander

8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — — — ➋ — — — —

8-channel expander with 120V AC blown fuse indicators

1492-XIMF-F120-2 — — — — — — — — — — — ➋ — — — — —

Feed-through Expander

Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — — — — — — ➋ ➋ — — — —

Publication 1492-TD008A-EN-P - March 2001

Page 41: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 41

Selection Tables, Continued

Bulletin 1771 PLC-5 IFMs and Cables, Continued

➊ Two or three expanders are connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.

➋ Cable Cat. No. 1492-CAB➊ R71 has only the N.O. contacts connected.

IFMs for Bulletin 1771 Digital 16-Point Isolated and 32-Point I/O Modules

Type of IFM Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1771-…

IAN

IBN

ID16

IQ16

IVN

OAN

OBN

OD16

ODD

OQ16

OVN

OW16

OWN

OWNA

Feed-through

Standard 1492-IFM40F J J M M K L L M M M L R L LExtra terminals 1492-IFM40F-2 J J — — K L L — — — L R L L3-wire sensor type input devices 1492-IFM40F-3 — J — — K — — — — — — — — —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM40D24 — J — — K — L — — — L — L L24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — — — — — L — — — L — L L24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 — J — — K — — — — — — — — —120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — — — — L — — — — — — L L120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 J — — — — — — — — — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 — J — — K — — — — — — — — —Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM40DS24-4 — — — — — — — — — M — — — —Isolated with 24V AC/DC LEDs and 4 terminals/input 1492-IFM40DS24A-4 — — — M — — — — — — — — — —Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM40DS120-4 — — — — — — — M M — — — — —Isolated with 120V AC LEDs and 4 terminals/input 1492-IFM40DS120A-4 — — M — — — — — — — — — — —Isolated with 240V AC LEDs and 4 terminals/input 1492-IFM40DS240A-4 — — — — — — — — — — — — — —

Fusible Extra terminals for outputs 1492-IFM40F-F-2 — — — — — L L — — — L — L LExtra terminals with 24V AC/DC blown fuse indicators 1492-IFM40F-F24-2 — — — — — — L — — — L — L LExtra terminals with 120V AC blown fuse indicators 1492-IFM40F-F120-2 — — — — — L — — — — — — L LIsolated with extra terminals for outputs 1492-IFM40F-FS-2 — — — — — — — M M M — R71 ➋ — —Isolated with extra terminals and 24V AC/DC blown fuse indicators

1492-IFM40F-FS24-2 — — — — — — — — — M — R71 ➋ — —

Isolated with 24V AC/DC blown fuse indicators and 4 terminals/output

1492-IFM40F-FS24-4 — — — — — — — — — M — — — —

Isolated with extra terminals and 120V blown fuse indicators 1492-IFM40F-FS120-2 — — — — — — — M M — — R71 ➋ — —Isolated with 120V AC/DC blown fuse indicators and 4 terminals/output

1492-IFM40F-FS120-4 — — — — — — — M M — — — — —

Isolated with 240V AC/DC blown fuse indicators and 4 terminals/output

1492-IFM40F-FS240-4 — — — — — — — — — — — — — —

Isolated with 24V AC/DC blown fuse indicators and 4 terminals/input

1492-IFM40F-FS24A-4 — — — M — — — — — — — — — —

Isolated with 120V AC/DC blown fuse indicators and 4 terminals/input

1492-IFM40F-FS120A-4 — — M — — — — — — — — — — —

Relay Master

40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — — — — — L — — — — — — —40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R — — — — — — L — — — — — — —

Relay Expander

Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — ➊ — — — — — — —Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — — — — — — —

Fusible Expander

8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — ➊ — — — — — — —8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — — — — — — —

Feed through Expander

Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — ➊ — — — — — — —

Publication 1492-TD008A-EN-P - March 2001

Page 42: Prog Controller Wiring Systems

42 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

Bulletin 1771 PLC-5 IFMs and Cables, Continued

These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005M is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM40F IFM to a Cat. No. 1771-ODD I/O module.

➋ Cable Cat. No. 1492-CAB➊ R71 has only the N.O. contacts connected.

The I/O module-ready cables have a wiring arm on one end to plug onto the front of a Bulletin 1771 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.

➌ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050WN is for a 5.0 m cable with a pre-wired Cat. No. 1771-WN wiring arm on one end.

➍ Includes an optional 3A fuse in the Wiring Arm for 1771 PLC mating I/O Modules.

Pre-Wired Cables for Bulletin 1771 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1771I/O Modules Cat. No.

1492-CABLE➊ F 0.5, 1.0, 2.5, 5.0 m Yes 20 1771-IAD, -IBD, -ICD, -IGD, -IND, -OAD, -OBD, -OGD, -OMD, -OND, -IMD

1492-CABLE➊ FF 0.5, 1.0, 2.5, 5.0 m Yes 20 1771-OAD, -OBD, -OND1492-CABLE➊ J 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-IAN, -IBN1492-CABLE➊ K 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-IVN1492-CABLE➊ L 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-OAN, -OBN, -OVN, -OWN, -OWNA1492-CABLE➊ M 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-ID16, -IQ16, -OD16, -ODD, -OQ161492-CABLE➊ R 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-OW161492-CAB➊ R71➋ 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-OW161492-CABLE➊ T 0.5, 1.0, 2.5, 5.0 m Yes 20 1771-IA, -IA2, -IB, -IH, -IN, -IT

I/O Module-Ready Cables for 1771 Digital I/O Modules

CableCat. No.

Standard Cable Lengths

Build-to-Order Available

No. of Conductors

Mating 1771I/O Modules Cat. No.

1492-CABLE➌ WA 1.0, 2.5, 5.0 m Yes 12 1771-IA, -IA2, -IB, -IC, -IH, -IM, -IN, -IT, -IV, -OA, -OB, -OC, -OM, -ON, -OP

1492-CABLE➌ WD 1.0, 2.5, 5.0 m Yes 12 1771-ID, -ID01, -OD, -ODZ, -OR, -OW, -OYL, -OZL1492-CABLE➌ WH 1.0, 2.5, 5.0 m Yes 20 1771-IAD, -IBD, -ICD, -IGD, -IMD, -IND, -OAD, -OBD, -OGD,

-OMD, -OND1492-CABLE➌ WHF 1.0, 2.5, 5.0 m Yes 20 1771-IBD ➍ , -OAD ➍ , -OBD ➍ , -OMD ➍ , -OND ➍

1492-CABLE➌ WN 1.0, 2.5, 5.0 m Yes 40 1771-IAN, -IBN, -ID16, -IQ16, -IV16, -OAN, -OBN, -OD16, -ODD, -OQ16, -OVN, -OW16, -OWN, -OWNA

Publication 1492-TD008A-EN-P - March 2001

Page 43: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 43

Selection Tables, Continued

Bulletin 1771 PLC-5 AIFMs and Cables

These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. You must first select the IFM from the preceding selection table.

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005E is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM8-3 IFM to a Cat. No. 1771-IFE I/O module. Build-to-order lengths are also available.

IFMs for Bulletin 1771 Analog I/O Modules

Type of AIFM Description of AIFM AIFM Cat. No. I/O Module Cat. No. 1771-…

IFE

(Diff

eren

tial)

IFE

(Sin

gle-

Ende

d

IL IR OFE

1

OFE

2

OFE

3

Feed-through 4-channel with 3 terminals/channel 1492-AIFM4-3 — — — — G G G6-channel isolated with 3…4 terminals/channel 1492-AIFM6S-3 — — — J — — —8-channel with 3 terminals/channel 1492-AIFM8-3 E F H — — — —

Thermocouple 6-channel with 3 terminals/channel 1492-AIFM6TC-3 — — — — — — —Fusible 8-channel with 5 terminals/channel 1492-AIFM8-F-5 E — — — — — —

16-channel with 3 terminals/channel 1492-AIFM16-F-3 — F — — — — —16-channel with 5 terminals/channel 1492-AIFM16-F-5 — F — — — — —

Pre-Wired Cables for Bulletin 1771 Analog I/O Modules

Cable Cat. No. Standard Cable Lengths Build-to-Order Available AIFM Connector Mating 1771 I/O Modules1492-ACABLE➊ E 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IFE Differential1492-ACABLE➊ F 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IFE Single-Ended1492-ACABLE➊ G 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1771-OFE1, -OFE2, -OFE31492-ACABLE➊ H 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IL1492-ACABLE➊ J 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IR

Publication 1492-TD008A-EN-P - March 2001

Page 44: Prog Controller Wiring Systems

44 Digital/Analog Programmable Controller Wiring Systems

Selection Tables, Continued

IFM-Ready I/O Cables

IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (CABLE➊ P and CABLE➊ Q, respectively). These cables allow the IFM to be used in specialty applications that require a custom connection.

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.

Build-to-Order Length Cables

All Bulletin 1492 cables are available in build-to-order lengths. Consult your local Allen-Bradley Sales Office or distributor for availability.

IFM-Ready I/O Cable

CableCat. No.

Standard Cable Lengths

Insulation Rating

No. Conductors

Conductor Size

Nominal Outer Diameter

Current/Conductor

Compatible IFM Cat. Nos.

1492-CABLE➊ P 1.0, 2.5, 5.0 m 300V, 80°C 20 22 AWG 9 mm (0.36 in.) 2 A 1492-IFM20…, 1492-XIM20…

1492-CABLE➊ Q 1.0, 2.5, 5.0 m 300V, 80°C 40 22 AWG 11.7 mm (0.46 in.) 2 A 1492-IFM40…, 1492-XIM40…

Build-to-Order Length Cables

Cable Lengths Increment Size Cable Length Codes Example Cat. No.

0.1…2.0 m 0.1 m 001…020 1492-CABLE015A (1.5 m cable)

2.0…10.0 m 0.5 m 020…100 1492-CABLE075P (7.5 m cable)

10.0…99.0 m 1.0 m 100…990 1492-CABLE150RTBB (15.0 m cable)

Publication 1492-TD008A-EN-P - March 2001

Page 45: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

Digital/Analog Programmable Controller Wiring Systems 45

Digital/Analog Programmab le Controller Wiring SystemsDigital IFM Specifications

For all IFM dimensions, refer to page 152.For all XIM dimensions, refer to page 158.For general Adhesive Label Card information, refer to page 162.For Field-Side Wiring Diagrams, refer to the Wiring System web page at http://www.ab.com/catalogs/b113. Refer to page 202 for specific platform web site information. Refer to the online documentation for new product information.

Symbols and Terminal Identification Conventions Used Throughout the Pinout Section

IFMCat. No.

Page No. for Specifications,

Application Notes, and Pinout

Page No. for

Adhesive Label Card

IFMCat. No.

Page No. for Specifications,

Application Notes, and Pinout

Page No. for

Adhesive Label Card

IFMCat. No.

Page No. for Specifications,

Application Notes, and Pinout

Page No. for

Adhesive Label Card

1492-IFM20F 46 163 1492-IFM20F-F240-2 68 169 1492-IFM40F-F-2 90 1721492-IFM20FN 47 174 1492-IFM20F-FS-2 69 177 1492-IFM40F-F24-2 91 1721492-IFM20F-2 48 166 1492-IFM20F-FS24-2 70 177 1492-IFM40F-F120-2 92 1721492-IFM20F-3 49 171 1492-IFM20F-FS24A-4 71 178 1492-IFM40F-FS-2 93 1831492-IFM20D24 50 163 1492-IFM20F-FS120-2 72 177 1492-IFM40F-FS24-2 94 1831492-IFM20D24N 51 174 1492-IFM20F-FS120-4 73 169 1492-IFM40F-FS24-4 95 1841492-IFM20D120 52 163 1492-IFM20F-FS120A-4 74 178 1492-IFM40F-FS120-2 96 1831492-IFM20D120N 53 174 1492-IFM20F-FS240-4 75 169 1492-IFM40F-FS120-4 97 1851492-IFM20D24-2 54 166 1492-IFM40F 76 165 1492-IFM40F-FS240-4 98 1841492-IFM20D24A-2 55 170 1492-IFM40F-2 77 172 1492-IFM40F-FS24A-4 99 1851492-IFM20D120-2 56 166 1492-IFM40F-3 78 179 1492-IFM40F-FS120A-4 100 1851492-IFM20D120A-2 57 170 1492-IFM40D24 79 165 1492-XIM4024-16R 101 1891492-IFM20D240-2 58 166 1492-IFM40D24-2 80 172 1492-XIM4024-8R 103 1861492-IFM20D240A-2 59 170 1492-IFM40D24A-2 81 172 1492-XIM2024-8R 105 1861492-IFM20D24-3 60 179 1492-IFM40D120-2 82 172 1492-XIM20120-8R 106 1861492-IFM20DS24-4 61 176 1492-IFM40D120A-2 83 172 1492-XIM24-8R 107 1871492-IFM20DS120-4 62 176 1492-IFM40D24-3 84 179 1492-XIM120-8R 109 1871492-IFM20F-F-2 63 166 1492-IFM40DS24-4 85 182 1492-XIMF-F24-2 111 1881492-IFM20F-F24-2 64 166 1492-IFM40DS24A-4 86 182 1492-XIMF-F120-2 113 1881492-IFM20F-F24A-2 65 181 1492-IFM40DS120-4 87 182 1492-XIMF-2 115 1881492-IFM20F-F120-2 66 166 1492-IFM40DS120A-4 88 182 — — —1492-IFM20F-F120A-2 67 181 1492-IFM40DS240A-4 89 182 — — —

~~

Fuse and Blown Fuse Indicator (where applicable)

LED Circuit

LED Indicator

Connector Pin

Field-Side Terminal

N.C./N.O. Relay Contact

Relay Coil Circuit

Page 46: Prog Controller Wiring Systems

46 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring Systems

1492-IFM20F

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 152.

Pinout

1492-IFM20F Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…264V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

2

3

18

19

20

A1

A2

A3

A18

A19

A20

Publication 1492-TD008A-EN-P - March 2001

Page 47: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 47

1492-IFM20FN

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 152.

Pinout

1492-IFM20FN Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B9

2

11

18

B1020

A2

A9

3

10

A11

A1019

Publication 1492-TD008A-EN-P - March 2001

Page 48: Prog Controller Wiring Systems

48 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus is isolated into two groups of 10 terminals. This allows each group of the I/O devices to reference a different power source.

4. Dimensions Refer to page 153.

Pinout1492-IFM20F-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…264V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

2

3

18

19

20

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

Publication 1492-TD008A-EN-P - March 2001

Page 49: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 49

1492-IFM20F-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 171. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power busses are connected to one common (one bus has 17 terminals, and one bus has 18 terminals). All of the input devices used must reference the same power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20F-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

17 (bottom row). 18 (middle row)

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

C1

C16

B1

B2

B17

B18

A1

A2

A16

A17

A18

3

18

1

20

Publication 1492-TD008A-EN-P - March 2001

Page 50: Prog Controller Wiring Systems

50 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20D24

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring The LEDs are powered from the two-position terminal block. Make only one connection to the power source for normal operation. Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 152.

Pinout

1492-IFM20D24 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

2

3

18

19

20

A1

A2

A3

A18

A19

A20

L1 (+)

L2 (-)

Publication 1492-TD008A-EN-P - March 2001

Page 51: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 51

1492-IFM20D24N

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 152.

Pinout

1492-IFM20D24N Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B9

2

11

18

B1020

A2

A9

3

10

A11

A1019

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 52: Prog Controller Wiring Systems

52 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20D120

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. This IFM is not recommended for use with input devices or programmable controller output circuits having an off-state leakage current exceeding 0.5 mA. Use Cat. No. 1492-IFM20D120N instead, or use Cat. No. 1492-IFM20D120A-2 for input modules and Cat. No. 1492-IFM20D120-2 for output modules. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The LEDs are isolated into two groups of eight terminals. This allows each group of the I/O devices to reference a different power source.

4. Dimensions Refer to page 152.

Pinout

1492-IFM20D120 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

A1

A2

A3

A10

A11

A18

A19

A20

L2 (-)

L2 (-)

1

2

3

10

11

18

19

20

Publication 1492-TD008A-EN-P - March 2001

Page 53: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 53

1492-IFM20D120N

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 152.

Pinout

1492-IFM20D120N Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B9

2

11

18

B1020

A2

A9

3

10

A11

A1019

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 54: Prog Controller Wiring Systems

54 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20D24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20D24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG(0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in.(0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B10

B11

B18

B19

B20

1

2

3

10

11

18

19

20

A1

A2

A9

A10

A11

A12

A19

A20

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 55: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 55

1492-IFM20D24A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20D24A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

20

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B20

1

2

3

18

20

A1

A2

A19

A20

B1919

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 56: Prog Controller Wiring Systems

56 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20D120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20D120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B10

B11

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

1

2

3

10

11

18

19

20

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 57: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 57

1492-IFM20D120A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20D120A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

20

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B20

A1

A2

A19

A20

B19

1

2

3

18

20

19

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 58: Prog Controller Wiring Systems

58 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20D240-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus comprises 10 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20D240-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B10

B11

B18

B19

B20

1

2

3

10

11

18

19

20

A1

A2

A9

A10

A11

A12

A19

A20LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 59: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 59

1492-IFM20D240A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 153.

Pinout

1492-IFM20D240A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

20

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B20

1

2

3

18

20

A1

A2

A19

A20

B1919

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 60: Prog Controller Wiring Systems

60 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20D24-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.

2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The LEDs are connected to one common. All of the input devices used must reference the same power source.

4. Dimensions Refer to page 153.

Pinout1492-IFM20D24-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

18

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

C1

C16

B1

B2

B17

B18

A1

A2

A17

A18

3

18

2

1

19

20

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 61: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 61

Digital/Analog Programmab le Controller Wiring Systems

1492-IFM20DS24-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.

2. Wiring Refer to the Label Section on page 176. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are eight individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 153.

Pinout1492-IFM20DS24-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…60V AC/DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

4.1 mA

No. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B2

B3

B6

A1

B1

B7

B10

B11

B14

B15

B18

B19

B20

A2

A3

A4

A9

A10

A11

A12

A17

A18

A19

A20

(even)

(even)

(odd)

(odd)

10

2

8

12

18

3

9

11

17

20

1

19

Publication 1492-TD008A-EN-P - March 2001

Page 62: Prog Controller Wiring Systems

62 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20DS120-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 176. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are eight individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 153.

Pinout1492-IFM20DS120-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.6 mA

No. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

10

2

8

B2

B3

B6

A1

B1

12 B7

18 B10

3 B11

9 B14

11 B15

17 B18

20 B19

B20

1

A2

A3

A4

A9

A10

A11

A12

A17

A18

A19

A20

(even)

(even)

(odd)

(odd)

19

Publication 1492-TD008A-EN-P - March 2001

Page 63: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 63

1492-IFM20F-F-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus and fuse clips are isolated into two groups of 10 terminals (eight fuse clips). This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 153.

Pinout1492-IFM20F-F-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

1

2

3

18

19

20

Publication 1492-TD008A-EN-P - March 2001

Page 64: Prog Controller Wiring Systems

64 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-F24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 153.

Pinout

1492-IFM20F-F24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

1

2

3

18

19

20

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 65: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 65

1492-IFM20F-F24A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input or output devices to reference a different power source.

5. Dimensions Refer to page 153.

Pinout

1492-IFM20F-F24A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

2

18

19

20

B1

B2

B3

B18

B19

B20

A1

A2

A3

A10

A20

A19

A18

A11

3

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 66: Prog Controller Wiring Systems

66 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-F120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 153.

Pinout

1492-IFM20F-F120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

1

2

3

18

19

20

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 67: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 67

1492-IFM20F-F120A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input devices to reference a different power source.

5. Dimensions Refer to page 153.

Pinout

1492-IFM20F-F120A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

1.2 mA

No. of Terminals per Device Common

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

2

3

18

19

20

B1

B2

B3

B18

B19

B20

A1

A2

A3

A10

A20

A19

A18

A11

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 68: Prog Controller Wiring Systems

68 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-F240-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Sixteen fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input devices to reference a different power source.

5. Dimensions Refer to page 154.

Pinout

1492-IFM20F-F240-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

1.2 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

2

3

18

19

20

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 69: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 69

1492-IFM20F-FS-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips are isolated into eight groups of terminals. This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 154.

Pinout

1492-IFM20F-FS-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

10

3

5

15

17

20

B1

B2

B3

B8

B9

B10

1

2

A1

A2

4 A3

6 A4

8 A5

12 A6

14 A7

16 A8

18 A9

19 A10

(odd)

Publication 1492-TD008A-EN-P - March 2001

Page 70: Prog Controller Wiring Systems

70 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-FS24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 154.

Pinout

1492-IFM20F-FS24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

(odd)

10

3

5

15

17

20

B1

B2

B3

B8

B9

B10

1

2

A1

A2

4 A3

6 A4

8 A5

12 A6

14 A7

16 A8

18 A9

19 A10

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 71: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 71

1492-IFM20F-FS24A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 178. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into two groups of terminals. This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 154.

Pinout

1492-IFM20F-FS24A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

3

4

5

16

17

18

B6

B7

B8

B11

B12

B13

2 B14

19 A14

A7

A9

A6

A8

A11

A13

A12

A10

6

15

B9

B10

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 72: Prog Controller Wiring Systems

72 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-FS120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source.

5. Dimensions Refer to page 154.

Pinout

1492-IFM20F-FS120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

(odd)

10

3

5

15

17

20

B1

B2

B3

B8

B9

B10

1

2

A1

A2

4 A3

6 A4

8 A5

12 A6

14 A7

16 A8

18 A9

19 A10

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 73: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 73

1492-IFM20F-FS120-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source.

5. Dimensions Refer to page 153.

Pinout

1492-IFM20F-FS120-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2.5 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

2

3

A11

B11A3

B3

4

1

5

A12

B12A4

B4

6

7

A13

B13A5

B5

8

9

A14

B14

A6

B6

12

11

19

A15

B15

A7

B7

14

13

A16

B16A8

B8

16

15

A17

B17A9

B9

18

17

A18

B18

A10

B10

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 74: Prog Controller Wiring Systems

74 Digital/Analog Programmable Controller Wiring Systems

1492-IFM20F-FS120A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 178. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into two groups of terminals. This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 154.

Pinout

1492-IFM20F-FS120A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V AC/DC

Maximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 A

Maximum Current (per Module) 12 A

Indicator Circuit Current (Nominal) 2.5 mA

No. of Terminals per Device Common —

Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)

Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12

No. of Wires 3 3 3 2 1 1

3

4

5

16

17

18

B6

B7

B8

B11

B12

B13

2 B14

19 A14

A7

A9

A6

A8

A11

A13

A12

A10

6

15

B9

B10

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 75: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 75

Digital/Analog Programmab le Controller Wiring Systems

1492-IFM20F-FS240-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source.

5. Dimensions Refer to page 153.

Pinout

1492-IFM20F-FS240-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2.5 mANo. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

2

3

A11

B11A3

B3

4

1

5

A12

B12A4

B4

6

7

A13

B13A5

B5

8

9

A14

B14

A6

B6

12

11

19

A15

B15

A7

B7

14

13

A16

B16A8

B8

16

15

A17

B17A9

B9

18

17

A18

B18

A10

B10

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 76: Prog Controller Wiring Systems

76 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 165. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 154.

Pinout

1492-IFM40F Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

A1

A2

A3

A18

A20

B1

B2

B3

1

3

5

35

39

2

4

6

(odd)

(even)

A1937

B18

B20

36

40

B1938

Publication 1492-TD008A-EN-P - March 2001

Page 77: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 77

1492-IFM40F-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus is isolated into four groups of 10 terminals. This allows each group of the I/O devices to reference a different power source.

4. Dimensions Refer to page 155.

Pinout1492-IFM40F-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B20

B21

B22

B23

1

3

5

35

39

2

4

6

(odd)

(even)

B1937

B38

B40

36

40

B3938

A1

A2

A9

A10

A11

A12

A19

A20

A21

A22

A29

A30

A31

A32

A39

A40

Publication 1492-TD008A-EN-P - March 2001

Page 78: Prog Controller Wiring Systems

78 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power busses are isolated into two groups of 18 terminals. This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block.

4. Dimensions Refer to page 155.

Pinout1492-IFM40F-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…60V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

18

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

TB2

TB1

5

35

C1

C16

B1B2

B17B18

A1A2

A17A18

6

36

C1

C16

B1B2

B17B18

A1A2

A17A18

TB1

TB2

(odd)

(even)

3

1

37

39

4

2

38

40

Publication 1492-TD008A-EN-P - March 2001

Page 79: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 79

1492-IFM40D24

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring The LEDs are powered off the two-position terminal block. Make only one connection to the power source for normal operation. Refer to the Label Section on page 165. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.

4. Dimensions Refer to page 154.

Pinout

1492-IFM40D24 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

1

3

5

35

37

39

A1

A2

A3

A18

A19

A20

L1 (+)

L2 (-)

(odd)

(even)

2

4

6

B1

B2

B3

36

38

40

B18

B19

B20

Publication 1492-TD008A-EN-P - March 2001

Page 80: Prog Controller Wiring Systems

80 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40D24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.

4. Dimensions Refer to page 155.

Pinout

1492-IFM40D24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B21B22B23

B30

B31

B38B39B40

246

20

22

363840

A21

A22

A29

A30

A31

A32

A39

A40

(even)

(even)

B1B2B3

B10

B11

B18B19B20

135

19

21

353739

A1

A2

A9

A10

A11

A12

A19

A20

(odd)

(odd)

LEDCircuit

Publication 1492-TD008A-EN-P - March 2001

Page 81: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 81

1492-IFM40D24A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of input devices to reference a different power source.

4. Dimensions Refer to page 155.

Pinout

1492-IFM40D24A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DC

Maximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 A

Maximum Current (per Module) 12 A

Indicator Circuit Current (Nominal) 2 mA

No. of Terminals per Device Common 10

Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 m2)

Wire Strip Length 0.32 in. (8 mm)

Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12

No. of Wires 3 3 3 2 1 1

B23

B30

B31

B38

B40

6

20

22

36

40

A31

A32

A39

A40

B3938

A21

A22

A29

A30

B212

B224

(even)

(even)

B3

B10

B11

B18

B20

5

19

21

35

39

A11

A12

A19

A20

B1937

A1

A2

A9

A10

B11

B23

(odd)

(odd)

LEDCircuit

Publication 1492-TD008A-EN-P - March 2001

Page 82: Prog Controller Wiring Systems

82 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40D120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.

4. Dimensions Refer to page 155.

Pinout

1492-IFM40D120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B21B22B23

B30

B31

B38B39B40

246

20

22

363840

A21

A22

A29

A30

A31

A32

A39

A40

(even)

(even)

B1B2B3

B10

B11

B18B19B20

135

19

21

353739

A1

A2

A9

A10

A11

A12

A19

A20

(odd)

(odd)

LEDCircuit

Publication 1492-TD008A-EN-P - March 2001

Page 83: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 83

1492-IFM40D120A-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of input devices to reference a different power source.

4. Dimensions Refer to page 155.

Pinout1492-IFM40D120A-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B23

B30

B31

B38

B40

6

20

22

36

40

A31

A32

A39

A40

B3938

A21

A22

A29

A30

B212

B224

(even)

(even)

B3

B10

B11

B18

B20

5

19

21

35

39

A11

A12

A19

A20

B1937

A1

A2

A9

A10

B11

B23

(odd)

(odd)

LEDCircuit

Publication 1492-TD008A-EN-P - March 2001

Page 84: Prog Controller Wiring Systems

84 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40D24-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation The power busses and LEDs are isolated into two groups of 18 terminals (16 LEDs). This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block.

4. Dimensions Refer to page 155.

Pinout

1492-IFM40D24-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common 18Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

TB2

TB1

5

35

C1

C16

B1B2

3

B17B18

A1A2

A17A18

1

37

39

6

36

C1

C16

B1B2

B17B18

A1A2

A17A18

TB1

TB2

4

2

38

40

(odd)

(even)

LED Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 85: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 85

1492-IFM40DS24-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 156.

Pinout

1492-IFM40DS24-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…60V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 4.1 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

5

19

B1

B8

21 B25

35 B32

6 B9

20 B16

22 B17

36 B24

A1

A2

A15

A16

A17

A18

A31

A32

(even)

(odd)

(odd)

(even)

Publication 1492-TD008A-EN-P - March 2001

Page 86: Prog Controller Wiring Systems

86 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40DS24A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 156.

Pinout

1492-IFM40DS24A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 4.1 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B9

B16

B1

B8

B17

B24

A1

A2

A31

A32

(odd)

(even)

B25

B32

(even)

(odd)

6

20

5

19

22

36

21

35

Publication 1492-TD008A-EN-P - March 2001

Page 87: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 87

Digital/Analog Programmab le Controller Wiring Systems

1492-IFM40DS120-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 156.

Pinout

1492-IFM40DS120-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 2.6 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

5

19

B1

B8

21 B25

35 B32

6 B9

20 B16

22 B17

36 B24

A1

A2

A15

A16

A17

A18

A31

A32

(even)

(odd)

(odd)

(even)

Publication 1492-TD008A-EN-P - March 2001

Page 88: Prog Controller Wiring Systems

88 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40DS120A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 156.

Pinout

1492-IFM40DS120A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 2.6 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

6

20

B9

B16

5 B1

19 B8

22 B17

36 B24

A1

A2

A31

A32

(odd)

(even)

21 B25

35 B32

(even)

(odd)

Publication 1492-TD008A-EN-P - March 2001

Page 89: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 89

1492-IFM40DS240A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Dimensions Refer to page 156.

Pinout

1492-IFM40DS240A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current 2.6 mANo. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B17

B32

6

36

(even)

A17

A32

5

35

(odd)

A1

B1

A16

B16

Publication 1492-TD008A-EN-P - March 2001

Page 90: Prog Controller Wiring Systems

90 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-F-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus and fuse clips are isolated into four groups of 10 terminals (eight fuse clips). This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 157.

Pinout1492-IFM40F-F-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

B21

B22

B23

B38

B39

B40

(odd)

(even)

A21

A22

A29

A30

A31

A32

A39

A40

1

3

5

35

37

39

2

4

6

36

38

40

Publication 1492-TD008A-EN-P - March 2001

Page 91: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 91

1492-IFM40F-F24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 157.

Pinout

1492-IFM40F-F24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

B21

B22

B23

B38

B39

B40

(odd)

(even)

A21

A22

A29

A30

A31

A32

A39

A40

1

3

5

35

37

39

2

4

6

36

38

40

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 92: Prog Controller Wiring Systems

92 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-F120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).

2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.

5. Dimensions Refer to page 157.

Pinout

1492-IFM40F-F120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• CSA Certified (File LR1234 Class 321107)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

10

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B1

B2

B3

B18

B19

B20

A1

A2

A9

A10

A11

A12

A19

A20

B21

B22

B23

B38

B39

B40

(odd)

(even)

A21

A22

A29

A30

A31

A32

A39

A40

1

3

5

35

37

39

2

4

6

36

38

40

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 93: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 93

1492-IFM40F-FS-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

5. Dimensions Refer to page 158.

Pinout1492-IFM40F-FS-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B3

B18

(even)

A3

A18

(odd)

6

36

5

35

Publication 1492-TD008A-EN-P - March 2001

Page 94: Prog Controller Wiring Systems

94 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-FS24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

5. Dimensions Refer to page 158.

Pinout

1492-IFM40F-FS24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

36

B3

B18

(even)

A3

A18

(odd)

6

5

35

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 95: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 95

1492-IFM40F-FS24-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 184. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

6. Dimensions Refer to page 157.

Pinout1492-IFM40F-FS24-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DC

Maximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 A

Maximum Current (per Module) 12 A

Indicator Circuit Current (Nominal) 2 mA

No. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)

Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12

No. of Wires 3 3 3 2 1 1

5

6

A18

B18

A2

B2

7

8

A19

B19

A3

B3

33

34

A32

B32

A16

B16

35

36

A33

B33

A17

B17

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 96: Prog Controller Wiring Systems

96 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-FS120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

5. Dimensions Refer to page 158.

Pinout

1492-IFM40F-FS120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2.5 mA

No. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B3

B18

(even)

A3

A18

(odd)

6

36

5

35

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 97: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 97

1492-IFM40F-FS120-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

6. Dimensions Refer to page 157.

Pinout

1492-IFM40F-FS120-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current 1.4 mANo. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

A2

B2

A4

B4

A30

B30

A32

B32

(odd)

(even)

A3

B3

A5

B5

A31

B31

A33

B33

5

6

7

8

33

34

35

36

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 98: Prog Controller Wiring Systems

98 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-FS240-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).

2. Wiring Refer to the Label Section on page 184. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

6. Dimensions Refer to page 157.

Pinout1492-IFM40F-FS240-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 204…264V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 1.4 mANo. of Terminals per Device Common

2

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

5

6

A18

B18

A2

B2

7

8

A19

B19

A3

B3

33

34

A32

B32

A16

B16

35

36

A33

B33

A17

B17

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 99: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 99

Digital/Analog Programmab le Controller Wiring Systems

1492-IFM40F-FS24A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

6. Dimensions Refer to page 157.

Pinout

1492-IFM40F-FS24A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current 3.1 mANo. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

5

6

7

8

A3

B3

A5

B5

33

34

A31

B31

35

36

A33

B33

(odd)

(even)

A2

B2

A4

B4

A30

B30

A32

B32

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 100: Prog Controller Wiring Systems

100 Digital/Analog Programmable Controller Wiring Systems

1492-IFM40F-FS120A-4

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.

2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.

4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.

5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.

6. Dimensions Refer to page 157.

Pinout1492-IFM40F-FS120A-4 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current 1.4 mANo. of Terminals per Device Common

1

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

A3

B3

A5

B5

A31

B31

A33

B33

(odd)

(even)

A2

B2

A4

B4

A30

B30

A32

B32

5

6

7

8

33

34

35

36

Blown Fuse Indicator Circuit

Publication 1492-TD008A-EN-P - March 2001

Page 101: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 101

1492-XIM4024-16R

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 189. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 158.

Pinout

Refer to page 102.

1492-XIM4024-16R Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

10 A12 A per adjacent pair

Maximum Current (per Module)

48 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common

16

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 102: Prog Controller Wiring Systems

102 Digital/Analog Programmable Controller Wiring Systems

1492-XIM4024-16R, Continued

Pinout, Continued

206

248

2810

3012

3214

3116

3418

3320

1222

1124

1426

1328

1630

1532

1834

1736

CJOUTCN

5

7

9

A3

K0

K1

K2

K3

K4

K5

K6

K7

A4

A5

B3

B4

B5

A6

A7

A8

11

B6

B7

B8

13

B9

B10

B11

15

B12

B13

B14

17

A9

A10

A11

19

A12

A13

A14

CN TB1~~

~~

~~

~~

~~

~~

~~

~~

8

21

23

25

A3

A4

A5

B3

B4

B5

A6

A7

A8

27

B6

B7

B8

29

B9

B10

B11

31

B12

B13

B14

33

A9

A10

A11

35

A12

A13

A14

5

9

7

8

10A2

B1

A1

B2

3

4

1

2

6A2

B1

A1

B2

40

37

38

39

4

1

2

3

CJOUT

CN TB2~~

~~

~~

~~

~~

~~

~~

~~

K8

K9

K10

K11

K12

K13

K14

K15

TB2

TB1

Publication 1492-TD008A-EN-P - March 2001

Page 103: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 103

1492-XIM4024-8R

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 158.

Pinout

Refer to page 104.

1492-XIM4024-8R Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

10 A12 A per adjacent pair

Maximum Current (per Module)

48 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common

8

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 104: Prog Controller Wiring Systems

104 Digital/Analog Programmable Controller Wiring Systems

1492-XIM4024-8R, Continued

Pinout, Continued

5

7

9

A3

K0

K1

K2

K3

K4

K5

K6

K7

A4

A5

B3

B4

B5

A6

A7

A8

11

B6

B7

B8

13

B9

B10

B11

15

B12

B13

B14

17

A9

A10

A11

19

A12

A13

A14

5

9

7

8

10A16

B15

A15

B16

3

4

1

2

6A2

B1

A1

B2

40

37

38

39

4

1

2

3

CJOUT

CN TB~~

~~

~~

~~

~~

~~

~~

~~

2021

2423

2825

3027

3229

3131

3433

3335

126

118

1410

1312

1614

1516

1818

1720

2222

2624

1926

2128

2330

2532

2734

2936

CJOUTCN

Publication 1492-TD008A-EN-P - March 2001

Page 105: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 105

1492-XIM2024-8R

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 159.

Pinout

1492-XIM2024-8R Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 10 A12 A per adjacent pair

Maximum Current (per Module)

48 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

CJOUT

2011

2412

2813

3014

3215

3116

3417

3318

CN

3

4

5

A3

A4

A5

B3

B4

B5

A6

A7

A8

6

B6

B7

B8

7

B9

B10

B11

8

B12

B13

B14

9

A9

A10

A11

10

K0

K1

K2

K3

K4

K5

K6

K7

A12

A13

A14

B16

B15

B2

B1

1

2

7

8

20

19

2

1

CN TB~~

~~

~~

~~

~~

~~

~~

~~

CJOUT

CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 106: Prog Controller Wiring Systems

106 Digital/Analog Programmable Controller Wiring Systems

1492-XIM20120-8R

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Dimensions Refer to page 159.

Pinout

1492-XIM20120-8R Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 96…132V ACMaximum Peak Voltage ➊ 600VpMaximum Current (per Output Contact)

10 A12 A per adjacent pair

Maximum Current (per Module) 48 AIndicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

CJOUT

2011

2412

2813

3014

3215

3116

3417

3318

CN

3

4

5

A3

A4

A5

B3

B4

B5

A6

A7

A8

6

B6

B7

B8

7

B9

B10

B11

8

B12

B13

B14

9

A9

A10

A11

10

K0

K1

K2

K3

K4

K5

K6

K7

A12

A13

A14

B16

B15

B2

B1

1

2

7

8

20

19

2

1

CN TB~~

~~

~~

~~

~~

~~

~~

~~

CJOUT

CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 107: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 107

1492-XIM24-8R

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 187. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. This relay expander must be used with a 24V DC relay master.

4. Dimensions Refer to page 159.

Pinout

Refer to page 108.

1492-XIM24-8R Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

10 A12 A per adjacent pair

Maximum Current (per Module)

48 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common

8

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 108: Prog Controller Wiring Systems

108 Digital/Analog Programmable Controller Wiring Systems

1492-XIM24-8R, Continued

Pinout, Continued

16

12

8

A1

A2

A3

B1

B2

B3

A4

A5

A6

6

B4

B5

B6

4

B7

B8

B9

3

B10

B11

B12

2

A7

A8

A9

1

A10

A11

A12

27

28

~~

~~

~~

~~

~~

~~

~~

~~

CJIN TB

K0

K1

K2

K3

K4

K5

K6

K7

130

2

31 3

324

25

6

26 8

29

5

7

9

10

2024

2423

2822

3021

3220

3119

3418

3317

1415

1214

1313

1611

1110

159

187

175

CJIN CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 109: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 109

1492-XIM120-8R

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 187. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. This relay expander must be used with a 120V AC relay master.

4. Dimensions Refer to page 159.

Pinout

Refer to page 110.1492-XIM120-8R Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 96…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 10 A12 A per adjacent pair

Maximum Current (per Module)

48 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 110: Prog Controller Wiring Systems

110 Digital/Analog Programmable Controller Wiring Systems

1492-XIM120-8R, Continued

Pinout, Continued

16

12

8

A1

A2

A3

B1

B2

B3

A4

A5

A6

6

B4

B5

B6

4

B7

B8

B9

3

B10

B11

B12

2

A7

A8

A9

1

A10

A11

A12

27

28

~~

~~

~~

~~

~~

~~

~~

~~

CJIN TB

K0

K1

K2

K3

K4

K5

K6

K7

130

2

31 3

324

25

6

26 8

29

5

7

9

10

2024

2423

2822

3021

3220

3119

3418

3317

1415

1214

1313

1611

1110

159

187

175

CJIN CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 111: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 111

1492-XIMF-F24-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the XIM and CABLE pinouts.

4. Dimensions Refer to page 159.

Pinout

Refer to page 112.

1492-XIMF-F24-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

4 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 112: Prog Controller Wiring Systems

112 Digital/Analog Programmable Controller Wiring Systems

1492-XIMF-F24-2, Continued

Pinout, Continued

16

12

8

B1

B2

B3

B7

B8

A1

A2

B4

B5

B6

6

A3

A4

A5

4

A6

A7

A8

3

2

1

27

28

CJIN

F8

F9

F10

F11

F12

F13

F14

F15

TB

130

2

31 3

324

25

6

26 8

29

5

7

9

10

2024

2423

2822

3021

3220

3119

3418

3317

1415

1214

1313

1611

1110

159

187

175

CJIN CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 113: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 113

1492-XIMF-F120-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the XIM and CABLE pinouts.

4. Dimensions Refer to page 159.

Pinout

Refer to page 114.

1492-XIMF-F120-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

4 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 114: Prog Controller Wiring Systems

114 Digital/Analog Programmable Controller Wiring Systems

1492-XIMF-F120-2, Continued

Pinout, Continued

16

12

8

B1

B2

B3

B7

B8

A1

A2

B4

B5

B6

6

A3

A4

A5

4

A6

A7

A8

3

2

1

27

28

CJIN

F8

F9

F10

F11

F12

F13

F14

F15

TB

130

2

31 3

324

25

6

26 8

29

5

7

9

10

2024

2423

2822

3021

3220

3119

3418

3317

1415

1214

1313

1611

1110

159

187

175

CJIN CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 115: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 115

Digital/Analog Programmab le Controller Wiring Systems

1492-XIMF-2

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.

2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the XIM and CABLE pinouts.

4. Dimensions Refer to page 159.

Pinout

Refer to page 116.

1492-XIMF-2 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

4 A

Indicator Circuit Current 2.0 mANo. of Indicators per Common —Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 116: Prog Controller Wiring Systems

116 Digital/Analog Programmable Controller Wiring Systems

1492-XIMF-2, Continued

Pinout, Continued

16

12

8

B1

B2

B3

B7

B8

A1

A2

B4

B5

B6

6

A3

A4

A5

4

A6

A7

A8

3

2

1

27

28

CJIN TB

130

2

31 3

324

25

6

26 8

29

5

7

9

10

2024

2423

2822

3021

3220

3119

3418

3317

1415

1214

1313

1611

1110

159

187

175

CJIN CJOUT

Publication 1492-TD008A-EN-P - March 2001

Page 117: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 117

Digital Cable Specifications

Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Digital pre-wired cables, when used with an IFM or XIM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The digital ready-to-wire cables provide one end of the cable pre-terminated, for either an IFM (IFM-ready cable) or a programmable controller I/O module (I/O module-ready cable).

Pre-Wired Cables

Specifications

The pre-wired cables have a Bulletin 1746 Removable Terminal Block, 1756 Removable Terminal Block, 1769 Removable Terminal Block, or 1771 Wiring Arm on one end and a cable connector on the other to connect to the IFM or XIM. The broad offering of digital pre-wired cables supports over 90 different 16- and 32-point Bulletin 1746, 1756, 1769, and 1771 digital I/O modules.

Publication 1492-TD008A-EN-P - March 2001

Page 118: Prog Controller Wiring Systems

118 Digital/Analog Programmable Controller Wiring Systems

Digital Cable Specifications, Continued

Pre-Wired Cables, Continued

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005A is for a 0.5 m cable for the 1746-IA16 I/O Module. Also refer to Build-to-Order Length Cables on page 44.

Digital Pre-Wired Cable Specifications

Cat.No.

Standard Cable Lengths

Insulation Rating

No. of Conductors

Conductor Size

Nominal Outer Diameter

I/O ModuleConnector Cat. No.

1492-CABLE➊ A 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block

1492-CABLE➊ B 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25B Blue Removable Terminal Block

1492-CABLE➊ C 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block

1492-CABLE➊ CR 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block

1492-CABLE➊ D 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25C Orange Removable Terminal Block

1492-CABLE➊ E 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25B Blue Removable Terminal Block

1492-CABLE➊ F 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1771-WH (16-Point/21 Terminal) Wiring Arm

1492-CABLE➊ FF 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm

1492-CABLE➊ G 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block

1492-CABLE➊ H 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1746-N3 40-Pin Cable Connector

1492-CABLE➊ J 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm

1492-CABLE➊ K 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm

1492-CABLE➊ L 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm

1492-CABLE➊ M 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm

1492-CABLE➊ N 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25C Orange Removable Terminal Block

1492-CABLE➊ R 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm

1492-CAB➊ R71 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm

1492-CABLE➊ S 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25C Orange Removable Terminal Block

1492-CABLE➊ T 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 11.7 mm (0.46") 1771-WA (8-Point/10 Terminal) Wiring Arm

1492-CABLE➊ U 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block

1492-CABLE➊ V 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block

1492-CABLE➊ W 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block

1492-CABLE➊ X 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block

1492-CABLE➊ Y 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1756-TBCH Removable Terminal Block

1492-CABLE➊ Z 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1756-TBCH Removable Terminal Block

1492-CAB➊ A69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block

1492-CAB➊ B69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block

1492-CAB➊ C69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN10 Removable Terminal Block

1492-CAB➊ D69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block

1492-CAB➊ E69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block

1492-CAB➊ F69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block

1492-CAB➊ G69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block

Publication 1492-TD008A-EN-P - March 2001

Page 119: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

Digital/Analog Programmable Controller Wiring Systems 119

Digital/Analog Programmab le Controller Wiring SystemsDigital Cable Specifications, Continued

Pinouts

Digital Pre-Wired Cables

The following diagrams illustrate how the individual conductors in the digital pre-wired cables are terminated at both ends. The description listed first is the wire color of the conductor connected to the removable terminal block (Bulletin 1746, 1756, and 1769 I/O) or wiring arm (1771 I/O). The number that follows in parentheses is the corresponding pin number of the IFM/XIM mating connector.

No Connection

Twisted Pair Jumper Wire

Individual Conductor

Base Color Stripe Color

Blue (24)

Black (23)

White/Green (22)

White/Red (19)

NC 20 or 40 Connector Pin Number

I/O Pin Connector Definition

1

2

39

40

1

2

19

20

20-Conductor Cable 40-Conductor Cable

IFM Mating Connector Definition

Page 120: Prog Controller Wiring Systems

120 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsDigital Cable Specifications, Continued

Pinouts, Continued

➊ Refer to footnote on page 125.

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

Red/Green (20)Blue/Red (19)

Black (1)White (2) Orange RTB

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

Red/Green (20)Blue/Red (19)

Red RTBRed (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

Red/Green (20)Blue/Red (19)

Blue RTB

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

Red/Green (20)Blue/Red (19)

Black (1)White (2) Red RTB

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18) Red/Green (20)Blue/Red (19)

Black (1)White (2) Blue RTB

ABCD00

01

02

03

04

05

06

07

10

11

12

13

14

15

16

17

E

White (2)Black (1)

Blue/Red (19)

Red (3)Green (4)

Orange (5)Blue (6)

White/Black (7)Red/Black (8)

Green/Black (9)Orange/Black (10)

Blue/Black (11)Black/White (12)

Red/White (13)Green/White (14)

Blue/White (15)Black/Red (16)White/Red (17)

Orange/Red (18)Red/Green (20)

ABCD00

01

02

03

04

05

06

07

10

11

12

13

14

15

16

17

E

White (2)Black (1)

Blue/Red (19)

Red (3)Green (4)Orange (5)Blue (6)White/Black (7)Red/Black (8)Green/Black (9)Orange/Black (10)Blue/Black (11)Black/White (12)Red/White (13)Green/White (14)Blue/White (15)Black/Red (16)White/Red (17)Orange/Red (18)Red/Green (20)

CAUTIONDISCONNECT

POWERBEFORE

SERVICING

ALL FUSES30-250V

FUSES

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

Black (1)

White (2)

Red/White (13)

Red RTB

Blue/Red (19)

Jumper

1492-CABLE➊ F 1492-CABLE➊ FF

1492-CABLE➊ D 1492-CABLE➊ E

1492-CABLE➊ G

1492-CABLE➊ C

1492-CABLE➊ A 1492-CABLE➊ B

Publication 1492-TD008A-EN-P - March 2001

Page 121: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 121

Digital Cable Specifications, Continued

Pinouts, Continued

➊ Refer to footnote on page 125.

1 2

39

White (2)Black (1)

Blue/Red (19)

Red (3)Green (4)Orange (5)Blue (6)White/Black (7)Red/Black (8)Green/Black (9)Orange/Black (10)Blue/Black (11)Black/White (12)Red/White (13)Green/White (14)Blue/White (15)Black/Red (16)White/Red (17)Orange/Red (18)

Red/Green (20)

40

Orange/Black-Green (32)

White/Black-Red (23)

Blue/Black-White (27)

Green/Black-Orange (31)

White/Red-Orange (35)

White/Black-Green (39)

Red/Black-White (24)

Black/Red-Green (28)

Orange/White-Blue (36)

Red/White-Green (40)

Orange/Green (21)

Green/Black-White (25)

White/Red-Green (29)

Blue/White-Orange (33)

White/Red-Blue (37)

Black/White-Red (22)

Orange/Black-White (26)

Red/Black-Green (30)

Black/White-Orange (34)

Black/White-Green (38)

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

White (2)

Black (1)Blue/Red (19)

Red (3)

Green (4)

Orange (5)

Blue (6)

White/Black (7)Green/Black (9)

Orange/Black-Green (32)

Blue/Black (11)

Black/White (12)

Red/White (13)

Green/White (14)

Blue/White (15)

Black/Red (16)

White/Red (17)

Orange/Red (18)Red/Green (20)

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

White/Black-Red (23)Blue/Black-White (27)

Green/Black-Orange (31)White/Red-Orange (35)White/Black-Green (39)

Red/Black (8)

Red/Black-White (24)Black/Red-Green (28)

Orange/White-Blue (36)Red/White-Green (40)

Orange/Green (21)Green/Black-White (25)White/Red-Green (29)Blue/White-Orange (33)White/Red-Blue (37)

Orange/Black (10)

Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)Black/White-Green (38)

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

White (2)

Black (1)

Blue/Red (19)

Red (3)

Green (4)

Orange (5)

Blue (6)

White/Black (7)Green/Black (9)

Orange/Black-Green (32)

Blue/Black (11)

Black/White (12)

Red/White (13)

Green/White (14)

Blue/White (15)

Black/Red (16)

White/Red (17)

Orange/Red (18)Red/Green (20)

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

White/Black-Red (23)Blue/Black-White (27)

Green/Black-Orange (31)White/Red-Orange (35)

White/Black-Green (39)

Red/Black (8)

Red/Black-White (24)Black/Red-Green (28)

Orange/White-Blue (36)

Red/White-Green (40)

Orange/Green (21)Green/Black-White (25)White/Red-Green (29)Blue/White-Orange (33)

White/Red-Blue (37)

Orange/Black (10)

Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)

Black/White-Green (38)

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

White (2)

Black (1)

Blue/Red (19)Red (3)

Green (4)

White/Black (7)

Orange/Black-Green (32)

Blue/Black (11)

Black/White (12)

Blue/White (15)

Black/Red (16)Red/Green (20)

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

White/Black-Red (23)Blue/Black-White (27)Green/Black-Orange (31)White/Red-Orange (35)White/Black-Green (39)

Red/Black (8)

Red/Black-White (24)Black/Red-Green (28)

Orange/White-Blue (36)Red/White-Green (40)

Orange (5)

Blue (6)

Green/Black (9)Red/White (13)

Green/White (14)

White/Red (17)

Orange/Red (18)

Orange/Green (21)Green/Black-White (25)

White/Red-Green (29)Blue/White-Orange (33)

White/Red-Blue (37)

Orange/Black (10)

Black/White-Red (22)Orange/Black-White (26)

Red/Black-Green (30)Black/White-Orange (34)

Black/White-Green (38)

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

NC

White/Black (7)

Orange/Black-Green (32)

Red/Green (20)

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

Red/Black (8)

Red/Black-White (24)

Black/Red-Green (28)

Orange/White-Blue (36)

Orange (5) Blue (6)

Red/White (13) Green/White (14)

White/Red (17)

Orange/Green (21)

Green/Black-White (25)

White/Red-Green (29)

Blue/White-Orange (33)

NC

NC

Blue/Red (19)

NC

NC

Green/Black (9)Blue/Black (11) Black/White (12)

NC

Blue/White (15) Black/Red (16)Orange/Red (18)

White/Black-Red (23)

Blue/Black-White (27)

Green/Black-Orange (31)

White/Red-Orange (35)

NC

Orange/Black (10)

Black/White-Red (22)

Orange/Black-White (26)

Red/Black-Green (30)

Black/White-Orange (34)

NC

1492-CABLE➊ H

1492-CABLE➊ J 1492-CABLE➊ K

1492-CABLE➊ M

1492-CABLE➊ L

Publication 1492-TD008A-EN-P - March 2001

Page 122: Prog Controller Wiring Systems

122 Digital/Analog Programmable Controller Wiring Systems

Digital Cable Specifications, Continued

Pinouts, Continued

➊ Refer to footnote on page 125.

1

19

2

20

Orange (5)

Black/White (12)

White/Red (17)

Red/Green (20)

Red/Black (8)

Blue/Red (19)

Red (3)

Green/White (14)

Blue/White (15)

Black (1)

White (2)

Blue (6)

Orange/Red (18)

Green (4)

Black/Red (16)

White/Black (7)

Blue/Black (11)

Green/Black (9)

Red/White (13)

Orange/Black (10)

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

NC

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

White (2)

NC

Orange RTB

1

19

2

20

Orange (5)

Black/White (12)

White/Red (17)

NC

Red/Black (8)

NC

Blue/Red (19)

Red (3)

Green/White (14)

Blue/White (15)

Black (1)

White (2)

Blue (6)

Orange/Red (18)

Green (4)

Black/Red (16)

White/Black (7)

Blue/Black (11)

Green/Black (9)

Red/White (13)

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

White (2)

Black (1)

Blue/Red (19)

Red (3)

Green (4)

Orange (5)

Blue (6)

White/Black (7)Green/Black (9)

Orange/Black-Green (32)

Blue/Black (11)

Black/White (12)

Red/White (13)

Green/White (14)

Blue/White (15)

Black/Red (16)

White/Red (17)

Orange/Red (18)Red/Green (20)

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

White/Black-Red (23)Blue/Black-White (27)

Green/Black-Orange (31)White/Red-Orange (35)White/Black-Green (39)

Red/Black (8)

Red/Black-White (24)Black/Red-Green (28)

Orange/White-Blue (36)Red/White-Green (40)

Orange/Green (21)Green/Black-White (25)White/Red-Green (29)Blue/White-Orange (33)White/Red-Blue (37)

Orange/Black (10)

Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)Black/White-Green (38)

1

19

2

20

White (2)

Orange (5)

Blue (6)

White/Black (7)

Blue/Black (11)

Black/White (12)

White/Red (17)

Orange/Red (18)

Red/Green (20)

Red/Black (8)

Black (1)

Blue/Red (19)

Red (3)

Green (4)

Green/Black (9)

Red/White (13)

Green/White (14)

Blue/White (15)

Black/Red (16)

Orange/Black (10)

Red (3)

Orange (5)

White/Black (7)

Green/Black (9)

Blue/Black (11)

Red/White (13)

Blue/White (15)

White/Red (17)

Green (4)

Blue (6)

Red/Black (8)

Orange/Black (10)

Black/White (12)

Green/White (14)

Black/Red (16)

Orange/Red (18)

Blue/Red (19)

Black (1)White (2)

Orange RTB

Jumper

1492-CABLE➊ U

1492-CABLE➊ R 1492-CABLE➊ V

1492-CABLE➊ S 1492-CABLE➊ W

White (2)Blue/Red (19) A

Red (3)Green (4)Orange (5)Blue (6)Blue/White (15)Black/Red (16)White/Red (17)Orange/Red (18)White/Black (7)Blue/Black (11)

0

1

2

3

4

5

6

7

B

1492-CABLE➊ T1492-CABLE➊ N

Publication 1492-TD008A-EN-P - March 2001

Page 123: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 123

Digital Cable Specifications, Continued

Pinouts, Continued

➊ Refer to footnote on page 125.

2

36

Blue/Red (19)

Orange (5)

Blue (6)

White/Black (7)Green/Black (9)

Orange/Black-Green (32)

Blue/Black (11)

Black/White (12)

Red/White (13)

Green/White (14)

Blue/White (15)

Black/Red (16)

White (2)

Orange/Red (18)Red/Green (20)

1

35

White/Black-Red (23)Blue/Black-White (27)

Green/Black-Orange (31)White/Red-Orange (35)

Red/Black (8)

Red/Black-White (24)Black/Red-Green (28)

Orange/White-Blue (36)

Orange/Green (21)Green/Black-White (25)

Black (1)Blue/White-Orange (33)

Orange/Black (10)

Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)

White/Red (17)

White/Red-Green (29)

White/Black-Green (39)

Red/White-Green (40)

2

36

Blue/Red (19)

Orange (5) Blue (6)White/Black (7)Green/Black (9)

Orange/Black-Green (32)

Blue/Black (11) Black/White (12)Red/White (13) Green/White (14)Blue/White (15) Black/Red (16)White/Red (17) Orange/Red (18)

Red/Green (20)

1

35

White/Black-Red (23)

Blue/Black-White (27)

Green/Black-Orange (31)

White/Red-Orange (35)

NC

Red/Black (8)

Red/Black-White (24)

Black/Red-Green (28)

Orange/White-Blue (36)NC

Orange/Green (21)

Green/Black-White (25)

White/Red-Green (29)

Blue/White-Orange (33)

NC

Orange/Black (10)

Black/White-Red (22)

Orange/Black-White (26)

Red/Black-Green (30)

Black/White-Orange (34)

NC

1

19

2

20

Orange (5)

Black/White (12)

White/Red (17)

Red/Green (20)

Red/Black (8)

Blue/Red (19)

Red (3)

Green/White (14)

Blue/White (15)

Black (1) White (2)

Blue (6)

Orange/Red (18)

Green (4)

Black/Red (16)

White/Black (7)

Blue/Black (11)

Green/Black (9)

Red/White (13)

Orange/Black (10)

1492-CABLE➊ X 1492-CABLE➊ Y

1492-CABLE➊ Z

Publication 1492-TD008A-EN-P - March 2001

Page 124: Prog Controller Wiring Systems

124 Digital/Analog Programmable Controller Wiring Systems

Digital Cable Specifications, Continued

Pinouts, Continued

➊ Refer to footnote on page 125.

1 White (2)Red (3)Orange (5)

White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)

Green (4)Blue (6)Red/Black (8)Black/White (12)Green/White (14)Black/Red (16)Orange/Red (18)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18 NCNC

Red (3)White(2)Black (1)

Green (4)Blue (6)

Red/Black (8)Orange/Black (10)

Black/White (12)Green/White (14)

Black/Red (16)Orange/Red (18)

Orange (5)White/Black (7)Green/Black (9)Blue/Red (19)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1492-CAB➊ D69

1 White (2)Black (1)

Red (3)Orange (5)

White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)Blue/Red (19)

Red/Green (20)

Green (4)Blue (6)Red/Black (8)Orange/Black (10)Black/White (12)Green/White (14)Black/Red (16)Orange/Red (18)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1492-CAB➊ E69

1492-CABLE➊ CR

1 Red (3)Green (4)Blue (6)

Red/Black (8)Orange/Black (10)

Black/White (12)Green/White (14)

Black/Red (16)Orange/Red (18)

Blue/Red (19)Red/Green (20)

Orange (5)White/Black (7)Green/Black (9)Black (1)White (2)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1 Red (3)Green (4)Blue (6)

Red/Black (8)Orange/Black (10)

Black/White (12)Green/White (14)

Black/Red (16)Orange/Red (18)

Blue/Red (19)Red/Green (20)

Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)Black (1)White (2)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1

Red (3)White/Black (7)

Blue/Red (19)Red/Green (20)

Blue/Black (11)Blue/White (15)

Black (1)Orange (5)Green/Black (9)Red/White (13)White/Red (17)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

Orange/Black (10

1 Red (3)Green (4)Blue (6)

Red/Black (8)Orange/Black (10)

Black/White (12)Green/White (14)

Black/Red (16)Orange/Red (18)

Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18 NCNC

1 Red (3)Green (4)Blue (6)

Red/Black (8)Orange/Black (10)

Black/White (12)Green/White (14)

Red/Green (20)

Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)

Blue/Red (19)

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

NCNC

NCNC

1 Blue (6)Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)Blue/Red (19)

Black/White-Red (22)

White/Black-Red (23)Orange/Black-White (26)

Blue/Black-White (27)Red/Black-Green (30)

Green/Black-Orange (31)Black/White-Orange (34)

White/Red-Orange (35)

Red/Black (8)Orange/Black (10)Black/White (12)Green/White (14)Black/Red (16)Orange/Red (18)Red/Green (20)

Orange/Green (21)Red/Black-White (24)

Green/Black-White (25)Black/Red-Green (28)

White/Red-Green (29)Orange/Black-Green (32)

Blue/White-Orange (33)Orange/White-Blue (36)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

NC

NC

NC

NC

NC

NC

NC

NC

1492-CAB➊ A69 1492-CAB➊ B69 1492-CAB➊ C69

1492-CAB➊ F69 1492-CAB➊ G69

1492-CAB➊ R71

Publication 1492-TD008A-EN-P - March 2001

Page 125: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 125

Digital/Analog Programmab le Controller Wiring SystemsDigital Cable Specifications, Continued

I/O Module-Ready Cables

The I/O module-ready cables have a pre-wired wiring arm or removable terminal block on one end to connect the programmable controller I/O module and 1240 individually colored #18 AWG conductors on the other. These cables provide the convenience of a pre-wired I/O module connector, while still allowing the flexibility to wire to standard terminal blocks.Pre-wired I/O module connectors include:

• Cat. No. 1746-N3 40-point plug-in connector (Cat. No. CABLE➊ N3)• Bulletin 1746 16-point removable terminal blocks in Red, Blue, and

Orange (Cat. No. CABLE➊ RTBR, ➊ RTBB, ➊ RTBO)• Cat. No. 1756-TBCH 36-point removable terminal block (Cat.

No. CABLE➊ TBCH)• Cat. No. 1756-TBNH 20-point removable terminal block (Cat.

No. CABLE➊ TBNH)• Cat. No. 1769-RTBN10 removable terminal block (Cat.

No. CABLE➊ RTN10)• Cat. No. 1769-RTBN18 20-point removable terminal block (Cat.

No. CABLE➊ RTN18)• Cat. No. 1771-WH 16-point wiring arm (Cat. No. CABLE➊ WH)• Cat. No. 1771-WN 32-point wiring arm (Cat. No. CABLE➊ WN)• Cat. No. 1771-WHF 16-point fused wiring arm (with fuses) (Cat.

No. CABLE➊ WHF)• Cat. No. 1771-WD 6-point wiring arm (Cat. No. CABLE➊ WD)• Cat. No. 1771-WA 8-point wiring arm (Cat. No. CABLE➊ WA)

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.

Publication 1492-TD008A-EN-P - March 2001

Page 126: Prog Controller Wiring Systems

126 Digital/Analog Programmable Controller Wiring Systems

Digital Cable Specifications, Continued

I/O Module-Ready Cables, Continued

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.

I/O Module-Ready Cable Specifications

Cat. No. Cable Lengths

Insulation Rating

Number of Conductors

Conductor Size

Nominal Outer Diameter

I/O ModuleConnector

1492-CABLE➊ N3 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.2 mm (0.44") 1746-N3 (40-Point) Plug-in Connector

1492-CABLE➊ RTBB 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-RT25B Blue Removable Terminal Block

1492-CABLE➊ RTBO 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-RT25C Orange Removable Terminal Block

1492-CABLE➊ RTBR 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-RT25R Red Removable Terminal Block

1492-CABLE➊ TBCH 1.0, 2.5, 5.0 m 300V 80°C 40 #18 AWG 14.1 mm (0.55") 1756-TBCH (36-Point) Removable Terminal Block

1492-CABLE➊ TBNH 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-TBNH (20-Point) Removable Terminal Block

1492-CABLE➊ RTN10 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 9.0 mm (0.36") 1769-RTBN10 Removable Terminal Block

1492-CABLE➊ RTN18 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 9.0 mm (0.36") 1771-RTBN18 (20-Point) Removable Terminal Block

1492-CABLE➊ WA 1.0, 2.5, 5.0 m 300V 80°C 12 #18 AWG 9.0 mm (0.36") 1771-WA (8-Point/10 Terminal) Wiring Arm

1492-CABLE➊ WD 1.0, 2.5, 5.0 m 300V 80°C 12 #18 AWG 9.0 mm (0.36") 1771-WD (6-Point/12 Terminal) Wiring Arm

1492-CABLE➊ WH 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-WH (16-Point/21 Terminal) Wiring Arm

1492-CABLE➊ WHF 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm

1492-CABLE➊ WN 1.0, 2.5, 5.0 m 300V 80°C 40 #18 AWG 14.1 mm (0.55") 1771-WN (32-Point/40 Terminal) Wiring Arm

Publication 1492-TD008A-EN-P - March 2001

Page 127: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 127

Digital Cable Specifications, Continued

I/O Module-Ready Cables, Continued

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.

Wire Colors for I/O Module-Ready Cables

Reference Number

Wire ColorBase/Stripe/Stripe

Reference Number

Wire ColorBase/Stripe/Stripe

1 Black 21 Orange/Green

2 White 22 Black/White/Red

3 Red 23 White/Black/Red

4 Green 24 Red/Black/White

5 Orange 25 Green/Black/White

6 Blue 26 Orange/Black/White

7 White/Black 27 Blue/Black/White

8 Red/Black 28 Black/Red/Green

9 Green/Black 29 White/Red/Green

10 Orange/Black 30 Red/Black/Green

11 Blue/Black 31 Green/Black/Orange

12 Black/White 32 Orange/Black/Green

13 Red/White 33 Blue/White/Orange

14 Green/White 34 Black/White/Orange

15 Blue/White 35 White/Red/Orange

16 Black/Red 36 Orange/White/Blue

17 White/Red 37 White/Red/Blue

18 Orange/Red 38 Black/White/Green

19 Blue/Red 39 White/Black/Green

20 Red/Green 40 Red/White/Green

Publication 1492-TD008A-EN-P - March 2001

Page 128: Prog Controller Wiring Systems

128 Digital/Analog Programmable Controller Wiring Systems

Digital Cable Specifications, Continued

I/O Module-Ready Cables, Continued

Below is the wire color table for I/O module-ready cables. Each colored conductor is given a reference number in the table. The reference number is used in the illustrations that follow to indicate the corresponding screw terminal.

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.

1 2

39 40

24

81012141618202224262830323436

6

13

7911131517192123252729313335

5

135791113151719

2468

101214161820

13

7

13

5

9 11

15171921232527293133353739

34

40

2468

101214161820222426283032

3836

123

45

14

6789

10111213

151617181920

123

45678 9 1011121314151617181920

1

23

4

5

789

10

11

12

6

1

2

3

4

5

7

8

9

10

6

2

4

6

8

10

14

16

18

12

1

3

5

7

9

13

15

17

11

1492-CABLE➊ N3 1492-CABLE➊ TBCH 1492-CABLE➊ TBNH 1492-CABLE➊ WN 1492-CABLE➊ WH 1492-CABLE➊ WF

1492-CABLE➊ WD 1492-CABLE➊ WA 1492-CABLE➊ RTBR1492-CABLE➊ RTBB1492-CABLE➊ RTBO

1

GreenRed

BlueRed/Black

Orange/BlackBlack/White

WhiteBlack

OrangeWhite/BlackGreen BlackBlue/Black

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1 BlackWhite

GreenRed

BlueRed/Black

Orange/BlackBlack/White

Green/WhiteBlack/Red

Orange/RedRed/Green

OrangeWhite/BlackGreen/BlackBlue/BlackRed/WhiteBlue/WhiteWhite/RedBlue/Red

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

1492-CAB➊ RTN10 1492-CAB➊ RTN18

Publication 1492-TD008A-EN-P - March 2001

Page 129: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 129

Digital Cable Specifications, Continued

IFM-Ready Cable Specifications

IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (Cat. Nos. CABLE➊ P and CABLE➊ Q, respectively). These cables allow the IFM to be used in specialty applications that require a custom connection.

Each colored conductor is connected to one pin of the molded cable connector as listed in the tables below.

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.

IFM-Ready Cable Specifications

Cat. No. Cable Lengths Insulation Rating

Number of Conductors

Conductor Size

Nominal Outer Diameter

Current/Conductor

CompatibleIFM Cat. Nos.

1492-CABLE➊ P 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 2 A 1492-IFM20_ _ _1492-XIM20_ _ _

1492-CABLE➊ Q 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 2 A 1492-IFM40_ _ _1492-XIM40_ _ _

1492-CABLE➊ P

Connector Pin Number

Wire ColorBase/Stripe/Stripe

Connector Pin Number

Wire ColorBase/Stripe/Stripe

1 Black 11 Blue/Black2 White 12 Black/White3 Red 13 Red/White4 Green 14 Green/White5 Orange 15 Blue/White6 Blue 16 Black/Red7 White/Black 17 White/Red8 Red/Black 18 Orange/Red9 Green/Black 19 Blue/Red10 Orange/Black 20 Red/Green

Publication 1492-TD008A-EN-P - March 2001

Page 130: Prog Controller Wiring Systems

130 Digital/Analog Programmable Controller Wiring Systems

Digital Cable Specifications, Continued

IFM-Ready Cable Specifications, Continued

➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.

1492-CABLE➊ Q

Connector Pin Number

Wire ColorBase/Stripe/Stripe

Connector Pin Number

Wire ColorBase/Stripe/Stripe

1 Black 21 Orange/Green

2 White 22 Black/White/Red

3 Red 23 White/Black/Red

4 Green 24 Red/Black/White

5 Orange 25 Green/Black/White

6 Blue 26 Orange/Black/White

7 White/Black 27 Blue/Black/White

8 Red/Black 28 Black/Red/Green

9 Green/Black 29 White/Red/Green

10 Orange/Black 30 Red/Black/Green

11 Blue/Black 31 Green/Black/Orange

12 Black/White 32 Orange/Black/Green

13 Red/White 33 Blue/White/Orange

14 Green/White 34 Black/White/Orange

15 Blue/White 35 White/Red/Orange

16 Black/Red 36 Orange/White/Blue

17 White/Red 37 White/Red/Blue

18 Orange/Red 38 Black/White/Green

19 Blue/Red 39 White/Black/Green

20 Red/Green 40 Red/White/Green

Publication 1492-TD008A-EN-P - March 2001

Page 131: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 131

Analog IFM Specifications

For all AIFM dimensions, refer to page 160.For general Adhesive Label Card information, refer to page 162.For Field-Side Wiring Diagrams, refer to the Wiring System web page at http://www.ab.com/catalogs/b113. Refer to page 202 for specific platform web site information. Refer to the online documentation for new product information.

Symbols and Terminal Identification Conventions Used Throughout the Pinout Section

1492-AIFM Field-Side Terminal ➊

1492 Pre-Wired Cable

I/O Module Connection

Fuse and Blown Fuse Indicator

One-Pole DIP Switch

Two-Pole DIP Switch

1492-AIFM and Cable Connection (D-Shell Pin)

Test Point

➊ Field-Side Terminal Identification Convention:

AIFMCat. No.

Page No. for Specifications,

Application Notes, and Pinout

Page No. for

Adhesive Label Card

AIFMCat. No.

Page No. for Specifications,

Application Notes, and Pinout

Page No. for

Adhesive Label Card

AIFMCat. No.

Page No. for Specifications,

Application Notes, and Pinout

Page No. for

Adhesive Label Card

1492-AIFM4-3 132 191 1492-AIFM4C-F-5 136 190 1492-AIFM16-F-5 140 1971492-AIFM6S-3 133 192 1492-AIFM4I-F-5 137 190 1492-AIFMQS 141 1981492-AIFM8-3 134 193 1492-AIFM8-F-5 138 195 1492-AIFMPI 142 1991492-AIFM6TC-3 135 192 1492-AIFM16-F-3 139 196 — — —

B1 B2 B3 B4 B5 . . .

A1 A2 A3 A4 A5 . . .

C1 C2 C3 C4 C5 . . .

B1 B2 B3 B4 B5 . . .

A1 A2 A3 A4 A5 . . .

Publication 1492-TD008A-EN-P - March 2001

Page 132: Prog Controller Wiring Systems

132 Digital/Analog Programmable Controller Wiring Systems

1492-AIFM4-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 191. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. DIP Switches Selectable resistors are available to current limit the Cat. Nos. 1771-OFE2 and -OFE3 output circuits. By opening the switch (off or down position), 250 Ω series impedance is inserted into the output circuit. Default switch position is on/closed/no series impedance. Do not exceed maximum loop impedance of output module (1200 Ω for -OFE2; 450 Ω for -OFE3).

4. Test Points With optional 250 Ω series impedance in output circuit (refer to DIP Switches), test points can be used to measure loop voltage/current. Refer to the Pinout for test point circuit location.

5. Shield Terminals Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

6. Dimensions Refer to page 160.

Pinout

1492-AIFM4-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Shield Common

4

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

A32

B3

A7

B7

A1

A2

A5

A6

B1

B2

B5

B6

A4A8

B4

B8

1

8

15

14

13

12

11

10

9

TP1 TP2

TP3 TP4

TP5 TP6

TP7 TP8

D-Shell Housing

Publication 1492-TD008A-EN-P - March 2001

Page 133: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 133

1492-AIFM6S-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 192. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Shield Terminals Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

4. Dimensions Refer to page 160.

Pinout1492-AIFM6S-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Shield Common

6

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B113

A1

B2

B3

A3

B4

B5

A5

B6

B7

A7

B8

B9

A9

B10

B11

12

25

24

11

23

22

9

21

19

D-Shell Housing

A11

B12

A2A4

A6A8A10A12

6

18

17

4

16

15

2

14

Publication 1492-TD008A-EN-P - March 2001

Page 134: Prog Controller Wiring Systems

134 Digital/Analog Programmable Controller Wiring Systems

1492-AIFM8-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 193. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Extra Terminals Eight field-side terminals are jumpered together on the AIFM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the AIFM and ACABLE pinouts.

4. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

5. Dimensions Refer to page 160.

Pinout

1492-AIFM8-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Device Common

8

No. of Terminals per Shield Common

8

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B13

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

B14

B15

B16

2

1

14

15

16

17

18

12

13

D-Shell Housing

A9A10

A11A12

A13

A14A15A16

25

24

23

22

20

21

A1A2

A3A4

A5

A6A7A8

4

6

810

19

Publication 1492-TD008A-EN-P - March 2001

Page 135: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 135

1492-AIFM6TC-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 192. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Shield Terminals Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

4. Cold Junction Compensation This AIFM contains on-board cold junction compensation through a thermistor and isothermal bar mounted to the field-side terminals. Do not install the additional cold junction sensor (provided with the Cat. No. 1756-IT6I thermocouple input module) on the removable terminal block of the pre-wired cable.

5. Dimensions Refer to page 160.

Pinout

1492-AIFM6TC-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

No. of Terminals per Shield Common

6

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B113

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

A7

A1

A3

A5

25

24

23

22

21

19

18

17

16

D-Shell Housing

15

14

6

20

12

11

A2A4

A6A8A10

A12

A9

A11

9

4

2

T

Publication 1492-TD008A-EN-P - March 2001

Page 136: Prog Controller Wiring Systems

136 Digital/Analog Programmable Controller Wiring Systems

1492-AIFM4C-F-5

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 190. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.

4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.

5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.

6. Test Points When using a two-wire transmitter, test points can be used to measure input loop current. Refer to the Pinout for test point circuit location.

7. Extra Terminals Four field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections.

8. Shield Terminals Four field-side terminals are jumpered together on AIFM and internally connected to the D-shell housing.

9. Dimensions Refer to page 160.

Pinout

1492-AIFM4C-F-5 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V DC

Maximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 A

Maximum Current (per Module) 12 A

Indicator Circuit Current (Nominal) 2 mA

No. of Terminals per Device Common 4

No. of Terminals per Shield Common 4

Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)

Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12

No. of Wires 3 3 3 2 1 1

B18

A8

B2

A5

B3

B4

B5

B6

B7

B8

B9

B10

B11

A2

A1

B12

15

14

13

12

11

2

10

9

1

TP1 TP2

TP3 TP4

D-Shell Housing

A12

A9

....

....

Publication 1492-TD008A-EN-P - March 2001

Page 137: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 137

1492-AIFM4I-F-5

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 190. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.

4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.

5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.

6. Test Points When using a two-wire transmitter, test points can be used to measure input loop current. Refer to the Pinout for test point circuit location.

7. Extra Terminals Four field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections.

8. Shield Terminals Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

9. Dimensions Refer to page 160.

Pinout

1492-AIFM4I-F-5 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common

4

No. of Terminals per Shield Common

4

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

B18

A8

B2

A5

B3

B4

B7

B5

B6

B8

B9

B10

B11

A4

A1

B12

15

14

13

2

12

11

10

9

1

TP1 TP2

TP7 TP8

D-Shell Housing

A12

A9

.....

.....

.....

Publication 1492-TD008A-EN-P - March 2001

Page 138: Prog Controller Wiring Systems

138 Digital/Analog Programmable Controller Wiring Systems

1492-AIFM8-F-5

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 195. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.

4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.

5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.

6. Extra Terminals Nine field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections.

7. Shield Terminals Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

8. Dimensions Refer to page 161.

Pinout

1492-AIFM8-F-5 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common

9

No. of Terminals per Shield Common

18

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

C1

C16

C2

C15

C3

C4C5

C6C7

C8C9

C10

C11

C13

C12

C14

D-Shell Housing

B2

B1

B9

B10

B18

A1

A18

3

21

1415

1617

1812

13

25

2423

2220

21

6

19

.....

.....

.....

Publication 1492-TD008A-EN-P - March 2001

Page 139: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 139

1492-AIFM16-F-3

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 196. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.

4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.

5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.

6. Shield Terminals Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

7. Dimensions Refer to page 161.

Pinout

1492-AIFM16-F-3 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 10…30V DC

Maximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit) 2 A

Maximum Current (per Module) 12 A

Indicator Circuit Current (Nominal) 2 mA

No. of Terminals per Shield Common

18

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)

Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12

No. of Wires 3 3 3 2 1 1

B2

B16

B3

B15

B4

B5

B6

B7

B8

B9

B10

B11

B13

B12

B14

D-Shell Housing

B18

B17

B1

C1

C16

A1

A18

3

2

1

14

15

16

17

18

12

13

25

24

23

22

20

21

4

6

810

19 .....

.....

Publication 1492-TD008A-EN-P - March 2001

Page 140: Prog Controller Wiring Systems

140 Digital/Analog Programmable Controller Wiring Systems

1492-AIFM16-F-5

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 197. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.

4. Isolation The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. All inputs within a group must reference the same power source.

5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.

6. Extra Terminals Sixteen field-side terminals (C9C16 on TB1 and TB2) are internally jumpered on the AIFM and connected to module common. Eighteen field-side terminals (B10B18 on TB1 and TB2) are internally jumpered on the AIFM and can be used for power source common connections. There are two field-side terminals (A17 and A18 on TB1) that can be externally jumpered to connect the two groups of field-side terminals.

7. Shield Terminals Sixteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

8. Dimensions Refer to page 161.

Pinout

1492-AIFM16-F-5 Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common

16

No. of Terminals per Shield Common

16

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

C1

B10

C2

B9

C3

C4

C5

C6

C7

C8

C9

C16

B1

A17

B2

D-Shell Housing

A18

B18

A1

A8

3

2

1

14

15

16

17

18

C1

B10

C2

B9

C3

C4

C5

C6

C7

C8

C9

C16

B1

B2

B18

A1

12

13

25

24

23

22

20

21

4

6

810

19 .....

.....

...

...

....

....

...

A8

...

Publication 1492-TD008A-EN-P - March 2001

Page 141: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 141

1492-AIFMQS

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 198. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 3 A per input, 12 A per AIFM.

4. Isolation The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. All inputs within a group must reference the same power source.

5. Extra Terminals Four field-side terminals (on TB1) are internally jumpered on the AIFM and connected to module common. Four field-side terminals (on TB1) are internally jumpered on the AIFM and can be used for power source common connections.

6. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

7. Dimensions Refer to page 161.

Pinout

1492-AIFMQS Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 3 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Shield Common

8

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

+INT 1

-INT 1

+RET 1

-RET 1

+OUT 1

OUT COM

+INT 2

-INT 2

+RET 2

-RET 2

+OUT 2

OUT COM

+INT 3

-INT 3

+RET 3

-RET 3

+OUT 3

OUT COM

+INT 4

-INT 4

+RET 4

-RET 4

+OUT 4

OUT COM

COM

LDT COM

LDT COM

GND

SH

SH

+ Interrogate 1

- Interrogate 1

+ Return 1

- Return 1

Drive Output 1

Drive Common

+ Interrogate 2

- Interrogate 2

+ Return 2

- Return 2

Drive Output 2

+ Interrogate 3

- Interrogate 3

+ Return 3

- Return 3

Drive Output 3

Drive Common

+ Interrogate 4

- Interrogate 4

+ Return 4

- Return 4

Drive Output 4

LDT Common

LDT Common

DRAIN

12

24

13

25

11

21

10

22

8

23

9

18

20

19

17

5

6

15

4

16

2

7

1

3

2

3

1

11

17

19

20

12

25

26

10

5

15

6

8

9

4

14

23

24

18

21

13

22

-V

-V1F

-V4F

+V

+V1F

+V4F

White/Blue

Blue/White

White/Orange

Orange/White

White/Green

White/Brown

White/Gray

Red/Orange

Red/Blue

Green/White

Brown/White

Gray/White

Orange/Red

Red/Green

Green/Red

Red/Brown

Brown/Red

Red/Gray

Gray/Red

Black/Blue

Blue/Black

Black/Orange

Orange/Black

Blue/Red

Publication 1492-TD008A-EN-P - March 2001

Page 142: Prog Controller Wiring Systems

142 Digital/Analog Programmable Controller Wiring Systems

1492-AIFMPI

➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.

➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:

Application Notes

1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.

2. Wiring Refer to the Label Section on page 199. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.

3. Fusing Two fuse holders for the outputs are included with the AIFM. Eight fuses (0.25 A, 5 x 20 mm) are included with the fused supply inputs. Do not exceed 2 A per output.

4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.

5. Jumpers J0J7 provide the option of connecting the negative inputs to the return. J8 commons the shield to the return. Default switch position is OPEN/OFF/NOT jumpered together.

6. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.

7. Dimensions Refer to page 161.

Pinout

Refer to page 143.

1492-AIFMPI Specifications

Approvals • UL Component Recognized (File E113724 Guide NRAQ2)

• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)

• CE Approved• Factory Mutual Listed

(File J.I. 3000590) FM approved

Voltage Rating 0…30V DCMaximum Peak Voltage ➊ 600Vp

Maximum Current (per Circuit)

2 A

Maximum Current (per Module)

12 A

Indicator Circuit Current (Nominal)

2 mA

No. of Terminals per Device Common

1

No. of Terminals per Shield Common

8

Wire Range (Rated Cross Section) ➋

#22…#12 AWG (0.2…4 mm2)

Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque

3.5…4.5 lb-in. (0.38…0.50 Nm)

Operating Temperature Range

0…+60°C

AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1

Publication 1492-TD008A-EN-P - March 2001

Page 143: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 143

1492-AIFMPI, Continued

Pinout, Continued

TB

B2

B4

F0

F1

B19

B9

B6

B8

F2

F3

B11F4

B13F5

B15F6

B17

B18

F7

F8

F9OUT 1

V1RTN

RTNOUT 0

RTNOUT 1

OUT 0

V1+DC

V0+24

2412

25

B20

A18

A19

A20

13

+VFUSED 0-7

CN TB

+

1

J032

3 A315 A4

4 A114 A2

+1–1

+0–0

2 A516 A61 A717 A88 A1018 A11

7 A1219 A136 A1420 A155 A1621 A17

+2–2

+3–3

+4–4

+5–5

+6–6

+7–7

CHANNEL 0

CHANNEL

0

1

IN

IN

IN

IN

IN

IN

IN

IN

2

3

4

5

6

7

+

1

J732 CHANNEL 7

B1

B3

922

SHELL

SHIELDIN 0...7

1

J832

B5

B7

B10

B12

B14

B16

A9 V0RTN

Publication 1492-TD008A-EN-P - March 2001

Page 144: Prog Controller Wiring Systems

144 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsAnalog Cable Specifications

Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Analog pre-wired cables, when used with an AIFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The analog ready-to-wire cables provide one end of the cable pre-terminated for an AIFM (AIFM-ready cable).

Pre-Wired Cables

Specifications

The pre-wired cables have a Bulletin 1746 Removable Terminal Block, Bulletin 1756 Removable Terminal Block, Bulletin 1769 Removable Terminal Block, or Bulletin 1771 Wiring Arm on one end and a D-shell on the other to connect to the AIFM. All analog cables have an overall shield and most have #22 AWG twisted pairs for additional noise immunity. In addition, most analog cables have prepared ring lugs on the drain wire for convenient grounding of the cable shield to the programmable controller chassis. The broad offering of analog pre-wired cables supports over 26 different Bulletin 1746, 1756, 1769, and 1771 analog, RTD, and thermocouple I/O modules.

Publication 1492-TD008A-EN-P - March 2001

Page 145: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 145

Analog Cable Specifications, Continued

Pre-Wired Cables, Continued

➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m and 5.0 m. To order, insert the desired cable length code into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable for the 1746-NI4 I/O Module. Also refer to Build-to-Order Length Cables on page 44.

➋ All pre-wired analog cables have an overall shield. On 1492-ACABLE➊ C and 1492-ACABLE➊ D, the drain wire is connected to the shield terminal on the I/O module connector. All other 1492-ACABLEs have a ring lug on the 7.87" (200 mm) exposed drain wire at the I/O module end of the cable.

➌ Not every connection is always used.

Analog Pre-Wired Cable Specifications

Cat. No. andLength ➊

Standard Cable Lengths

I/O ModuleConnector

AIFM Connector

No. of Conductors ➋➌

Insulation Rating

Conductor Size

Nominal Outer Diameter

1492-ACABLE➊ A 0.5, 1.0, 2.5, 5.0 m 1746-RT28 12-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ B 0.5, 1.0, 2.5, 5.0 m 1746-RT26 2-Position and 1746-RT27 8-Position Removable Terminal Block

15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ C 0.5, 1.0, 2.5, 5.0 m 1746-RT25G Green Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ D 0.5, 1.0, 2.5, 5.0 m 1746-RT25G Green Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ E 0.5, 1.0, 2.5, 5.0 m 1771-WG (21 terminal) 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")1492-ACABLE➊ F 0.5, 1.0, 2.5, 5.0 m 1771-WG (21 terminal) Wiring Arm 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ G 0.5, 1.0, 2.5, 5.0 m 1771-WC (10 terminal) Wiring Arm 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ H 0.5, 1.0, 2.5, 5.0 m 1771-WF (18 terminal) Wiring Arm 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ J 0.5, 1.0, 2.5, 5.0 m 1771-WF (18 terminal) Wiring Arm 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ L 0.5, 1.0, 2.5, 5.0 m 1746-RT28 12-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ M 0.5, 1.0, 2.5, 5.0 m 1757-PIM 36-Position Removable Terminal Block 25-pin D-shell 11 Twisted Pairs 300V 80°C 22 AWG 11.5 mm (0.45")

1492-ACABLE➊ Q 0.5, 1.0, 2.5, 5.0 m 1746-QS (26 terminal D-shell) 25-pin D-shell 12 Twisted Pairs 300V 80°C 22 AWG 10.2 mm (0.40")

1492-ACABLE➊ X 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")1492-ACABLE➊ Y 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ Z 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACAB➊ A46 0.5, 1.0, 2.5, 5.0 m 1746-RT25G Green Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 10.2 mm (0.40")

1492-ACABLE➊ TA 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ TB 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ TC 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ TD 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ UA 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ UB 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ UC 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ UD 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ VA 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 15-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ VB 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 15-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")

1492-ACABLE➊ WA 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ WB 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")

1492-ACABLE➊ AA69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN10 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")1492-ACABLE➊ AB69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN10 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ BA69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ BB69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

1492-ACABLE➊ BC69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")1492-ACABLE➊ BD69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")

Publication 1492-TD008A-EN-P - March 2001

Page 146: Prog Controller Wiring Systems

146 Digital/Analog Programmable Controller Wiring Systems

Analog Cable Specifications, Continued

Pinouts

Analog Pre-Wired Cables

The following diagrams indicate how the analog pre-wired cables are connected on both ends. The description listed first is the wire color of the conductor connected to the screw terminal on the respective Wiring Arm or Removable Terminal Block. The number that follows in parentheses is the corresponding pin number in the D-shell connector on the other end.

No Connection

Twisted Pair Jumper Wire

Individual Conductor

Base Color Stripe Color

Blue (24)

Black (23)

White/Green (22)

White/Red (19)

NC 20 or 40 Connector Pin Number

Shield

Output Pin Connector Definition

1111

8 13

25

14

15

9

15-Pin D-Shell Connector 25-Pin D-Shell Connector

AIFM Mating Connector Definition

Publication 1492-TD008A-EN-P - March 2001

Page 147: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 147

Analog Cable Specifications, Continued

Pinouts, Continued

Red (3)Black (2)

NC

White (1)Black (14)

Green (15)Black (16)

Blue (17)Black (18)

Yellow (12)Black (13)

Brown (25)Black (24)

Orange (23)Black (22)

Red (20)White (21)

Drain

White/Violet (25)

NC

Blue (13)

White/Orange (21)

Orange (9)

Green (12)

White/Yellow (22)

NC

NC

White/Blue (24)

White/Green (23)

Yellow (11)

NC

White/Red (19)

White/Brown (18)

Red (6)

Drain

NC

Yellow (2)

Black (1)

White (14)

Black (13)

Red (8)Black (15)

Blue (10)

Black (9)

Green (12)Black (11)

01

01

2

3

4

5

6

7

Red (8)

NCBlack (15)

White (14)

Yellow (2)

Black (13)

Green (12)

NCBlack (11)

Blue (10)

Black (1)Black (9)

01

2

34

5

6

78

9

1011

1492-ACABLE___A 1492-ACABLE___B 1492-ACABLE___C

1492-ACABLE___D

Red (3)

Black (2)

NC

White (1)

Black (14)

Green (15)

Black (16)

Blue (17)

Black (18)

Yellow (12)

Black (13)

Brown (25)

Black (24)

Orange (23)

Black (22)

Red (20)

White (21)

NC

NC

Red (6)

Green (19)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

Red (3)

Brown (2)

Black (1)

White (14)

Orange (4)

White/Black (15)

White/Brown (16)

White/Red (17)

White/Orange (18)

Blue (10)

Violet (12)

Gray (13)

White/Black/Brown (25)

White/Gray (24)

Green (8)

White/Violet (23)

White/Blue (22)

White/Yellow (20)

White/Green (21)

Yellow (6)

NC

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

1492-ACABLE___E 1492-ACABLE___F

Publication 1492-TD008A-EN-P - March 2001

Page 148: Prog Controller Wiring Systems

148 Digital/Analog Programmable Controller Wiring Systems

Analog Cable Specifications, Continued

Pinouts, Continued

NCNC

18

16

14

12

10

8

6

4

2

Red (3)Black (2)White (1)Black (14)Green (15)Black (16)Blue (17)Black (18)

Yellow (12)Black (13)Brown (25)Black (24)Orange (23)Black (22)Red (20)White (21)

White (14)

Black (13)

Red (8)

Black (15)

Blue (10)

Black (9)

Green (12)

Black (11)

NC

NC

A

0

1

2

3

4

5

6

7

B

2

36

1

35

Red (4) (3) White

Black (14)(15) Black

Black (18)

Black (16)Green (2)(1) Blue

(17) Black

NCNC

NCNC

NCNCNC

NCNC

NC

NC

Yellow (8)(7) Brown(19) Black

NCNC

NCNC

Orange (6)Black (20)

(5) Red(21) White

Red (12)Green (25)

NC(24) Red

(13) Blue

18

16

14

12

10

8

6

4

2

White/Violet (25)Green (12)Blue (13)White/Green (23)Yellow (11)White/Blue (24)White/Orange (21)Orange (9)White/Yellow (22)White/Brown (18)Red (6)White/Red (19)White (16)Brown (4)White/Black (17)Violet (14)Black (2)Gray (15)

1492-ACABLE___H 1492-ACABLE___J

Red (8)

Black (15)

White (14)Black (13)

NC

NC

Green (11)Black (2)

NC

NC

Blue (9)

Black (1)

01

2

34

5

6

78

9

1011

1492-ACABLE___L1492-ACABLE___G

Black/Orange (2)Orange/Black (1)

Green/White (23)White/Green (11)

Red/Blue (8)

Blue/Red (7)

Blue/Black (16)

918

26

110 19

Black/Blue (4)

Gray/Red (15)

Red/Gray (15)

Gray/White (22)

White/Gray (22) Brown/White (22)

White/Brown (9)

Red/Brown (5)Brown/Red (17)

Red/Green (20)Green/Red (19)

Orange/Red (18)Red/Orange (6)

Orange/White (25)White/Orange (13)

Blue/White (24)White/Blue (12)

1492-ACABLE___Q1492-ACABLE___M

Publication 1492-TD008A-EN-P - March 2001

Page 149: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 149

Analog Cable Specifications, Continued

Pinouts, Continued

1Red (3)Brown (2)Black (1)

White(14)Orange (4)Yellow (6)

White/Black (15)White/Brown (16)

White/Red (17)White/Orange (18)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Green (8)Blue (10)

Violet (12)Gray (13)

White/Yellow (20)White/Blue (22)

White/Violet (23)

White/Gray (24)White/Black/Brown (25)

White/Green (21)

1Red (3)Black (2)White (1)Black(14)

Yellow (6)Black (21)

Green (15)Black (16)Blue (17)

Black (18)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

1Red (3)Black (2)White (1)Black(14)

Yellow (6)Black (21)

Green (15)Black (16)Blue (17)

Black (18)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

1Red (3)Black (2)White (1)Black(14)

Red (6)Green (19)

Green (15)Black (16)Blue (17)

Black (18)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Yellow (12)Black (13)

Red (20)Black (22)

Orange (23)

Black (24)Brown(25)

White (21)

1Red (3)J1Black (2)

White (1)Black(14)

Red (6)Green (19)

Green (15)Black (16)Blue (17)

Black (18)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

J2

J3

J4

J5

J6

J7

J8

Yellow (12)Black (13)

Red (20)Black (22)

Orange (23)

Black (24)Brown(25)

White (21)

1Red (3)Brown (2)Black (1)

White (14)

White/Black (15)White/Brown (16)

White/Red (17)White/Yellow (18)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

Yellow (6)

Green (8)

Orange (4)

Violet (12)Gray (13)

Blue (10)White/Gray (24)

White/Black/Brown (25)

White/Yellow (20)White/Blue (22)

White/Violet (23)

White/Green (21)

1Red (3)Black (1)

White/Black (15)White/Red (17)White/Blue (22)Orange (4)

Yellow (6)Violet (12)

White/Black/Brown (25)White/Violet (23)

White/Yellow (20)

White/Brown (16)Brown (2)Gray (13)

White/Red-Blue (1)Orange/Green (1)Green/Black-White (1)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

20

32

34

36

1Red (3)Black (1)

White/Black (15)White/Red (17)

Orange (4)Yellow (6)

Violet (12)White/Black/Brown (25)

White/Violet (23)White/Yellow (20)

White (14)

Gray (13)White/Gray (24)White/Blue (22)

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

White/Brown (16)

Brown (2)

White/Orange (18)

White/Green (21)

1492-ACABLE___TA

1492-ACABLE___UA

1492-ACABLE___UB

1492-ACABLE___TB

1492-ACABLE___TC 1492-ACABLE___TD

1492-ACABLE___UC 1492-ACABLE___UD

Publication 1492-TD008A-EN-P - March 2001

Page 150: Prog Controller Wiring Systems

150 Digital/Analog Programmable Controller Wiring Systems

Analog Cable Specifications, Continued

Pinouts, Continued

Red (8)Black (15)

Black (13)White (14)

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

Green (12)Black (11)

Black (9)Blue (10)

White/Blue (24)

Yellow (11)

White/Green (23)

White/Red (19)

Red (6)

White/Brown (18)

NC

Gray (15)

Black (2)

Violet (14)

Blue (13)

Green (12)

White/Violet (25)

White/Yellow (22)

Orange (9)

White/Orange (21)

NC

White/Black (17)

Brown (4)

White (16)

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

Black (18)

Blue (24)

NC

Black (23)

Yellow (19)

Brown (6)Black (20)

Orange (15)

NC

Black (14)

Red (13)

NC

Black (25)

White (22)

NC

Black (21)

Green (17)

NC

Black (16)

NC

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

Blue (24)

Black (23)

Yellow (19)

Black (18)

NC

Black (14)

NC

Red (13)

Black (25)

White (22)

Black (21)

Green (17)

Black (16)

Orange (15)

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

Red (8)

Black (15)Black (13)White (14)

Green (12)Black (11)Black (9)

Blue (10)

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

Yellow (12) Red (3)

Black (24)Black (13)

Brown (25)

Orange (23)

Black (22)White (21)

Black (2)Black (14)White (1)

Red (6)

Black (18)Black (16)

Green (15)

Blue (17)Red (20)

Green (19)

Yellow (12) Red (3)

Black (24)Black (13)

Brown (25)

Orange (23)

Black (22)

White (21)

Black (2)Black (14)White (1)

Red (6)

Black (18)Black (16)

Green (15)

Blue (17)Red (20)

1

3

5

7

9

11

13

15

17

19

2

4

6

8

10

12

14

16

18

20

NC

NC

Green (19)

1492-ACABLE___VA 1492-ACABLE___VB

1492-ACABLE___WA 1492-ACABLE___WB

1492-ACABLE___X 1492-ACABLE___Y 1492-ACABLE___Z

Publication 1492-TD008A-EN-P - March 2001

Page 151: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 151

Analog Cable Specifications, Continued

Pinouts, Continued

Red (8)

White (14)

Green (12)

Blue (10)Black (9)

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

Brown (2)Red(3)

Black (1)

Violet (15)

White (17)

Orange (6)

Yellow (12)

White/Violet (25)

White/Green (23)

White/Red (20)

Blue (14)

Gray (16)

White/Black (18)

White/Brown (19)

Green (13)

White/Blue (24)

White/Yellow (22)

White/Orange (21)

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

Red (8)

White (14)

Green (12)

Blue (10)

Black (9)

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

Red (8)

Black (15)

Black (13)

White (14)

1

3

5

7

9

2

4

6

8

10

NC

NCNC

NC

NCNC

Red (8)Black (15)

Black (13)White (14)

1

3

5

7

9

2

4

6

8

10NC

NC

NC

Red (8)

White (14)

NC

NC

NC

Red (8)

White (14)

Green (12)

Blue (10)

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

NC

NC

NC

NC

NC

NC

NCNC

NCNC

Black (15)

Black (13)

Black (11)

Black (9)

Red (8)

White (14)

Green (12)

Blue (10)

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

NC

NC

NC

NCNC

Black (15)

Black (13)

Black (11)

Black (9)

1492-ACAB___AB69

1492-ACAB___BA691492-ACAB___A46

1492-ACAB___AA69

1492-ACAB___BB69 1492-ACAB___BC69 1492-ACAB___BD69

Publication 1492-TD008A-EN-P - March 2001

Page 152: Prog Controller Wiring Systems

152 Digital/Analog Programmable Controller Wiring Systems

DimensionsDigital IFM Mating Connector

Analog D-Shell Connector

Digital IFM DimensionsCat. Nos. 1492-IFM20F, 1492-IFM20D24, 1492-IFM20D120

Cat. Nos. 1492-IFM20FN, 1492-IFM20D24N, 1492-IFM20D120N

54.4 mm(2.15 in.)

39 mm(1.54 in.)

11.7 mm(0.46 in.)

10 mm(1.40 in.)

35.9 mm(1.42 in.)

29 mm(1.15 in.)

38 mm(1.50 in.)

34.3 mm(1.35 in.)

10 mm(1.40 in.)

9.0 mm(0.36 in.)

20-Point Cable Dimensions 40-Point Cable Dimensions

1.8 in.44 mm

1.6 in.39 mm

0.7 in.17 mm

2.4 in.60 mm

0.7 in.17 mm

1.6 in.39 mm

2.3 in.58 mm

2.9 in.73 mm

15-Pin D-Shell Dimensions 25-Pin D-Shell Dimensions

4.33 in.(110 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

2.36 in.(60 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 153: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 153

Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM20F-2, 1492-IFM20D24-2, 1492-IFM20D24A-2, 1492-IFM20D120-2,

1492-IFM20D120A-2, 1492-IFM20D240-2, 1492-IFM20D240A-2

Cat. Nos. 1492-IFM20F-3, 1492-IFM20D24-3

Cat. Nos. 1492-IFM20DS24-4, 1492-IFM20DS120-4

Cat. Nos. 1492-IFM20F-F-2, 1492-IFM20F-F24-2, 1492-IFM20F-F120-2, 1492-IFM20F-F120A-2, 1492-IFM20F-FS120-4, 1492-IFM20F-FS240-4, 1492-IFM20F-F24A-2

4.33 in.(110 mm)

2.19 in.(55.5 mm) 1.67 in.

(42.5 mm)

2.78 in.(70.5 mm)

3.27 in.(83 mm)

4.33 in.(110 mm)

2.74 in.(69.5 mm)

3.27 in.(83 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

2.78 in.(70.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm) 2.19 in.

(55.5 mm)

4.33 in.(110 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

4.33 in.(110 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 154: Prog Controller Wiring Systems

154 Digital/Analog Programmable Controller Wiring Systems

Digital IFM Dimensions, Continued Cat. No. 1492-IFM20F-F240-2

Cat. Nos. 1492-IFM20F-FS-2, 1492-IFM20F-FS24-2, 1492-IFM20F-FS120-2

Cat. Nos. 1492-IFM20F-FS24A-4, 1492-IFM20F-FS120A-4

Cat. Nos. 1492-IFM40F, 1492-IFM40D24

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

4.72 in.(120 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

2.36 in.(60 mm)

2.19 in(55.5 mm)

2.78 in(70.5 mm)

3.15 in(80 mm)

1.67 in(42.5 mm)

3.27 in(83 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

4.33 in.(110 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 155: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 155

Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM40F-2, 1492-IFM40D24-2, 1492-IFM40D24A-2, 1492-IFM40D120-2,

1492-IFM40D120A-2

Cat. Nos. 1492-IFM40F-3, 1492-IFM40D24-3

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

8.27 in.(210 mm)

2.74 in.(69.5 mm)

3.27 in.(83 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

2.78 in.(70.5 mm)

8.27 in.(210 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 156: Prog Controller Wiring Systems

156 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsDigital IFM Dimensions, Continued Cat. Nos. 1492-IFM40DS24-4, 1492-IFM40DS120-4

Cat. Nos. 1492-IFM40DS24A-4, 1492-IFM40DS120A-4, 1492-IFM40DS240A-4

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm) 2.19 in.

(55.5 mm)

6.69 in.(170 mm)

6.69 in.(170 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm) 2.19 in.

(55.5 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 157: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 157

Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM40F-F-2, 1492-IFM40F-F24-2, 1492-IFM40F-F120-2

Cat. Nos. 1492-IFM40F-FS120-4, 1492-IFM40F-FS120A-4, 1492-IFM40F-FS24-4, 1492-IFM40F-FS24A-4, 1492-IFM40F-FS240-4

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

8.27 in.(210 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm) 2.19 in.

(55.5 mm)

7.09 in.(180 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 158: Prog Controller Wiring Systems

158 Digital/Analog Programmable Controller Wiring Systems

Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM40F-FS-2, 1492-IFM40F-FS24-2, 1492-IFM40F-FS120-2

Digital XIM Dimensions Cat. No. 1492-XIM4024-8R

Cat. No. 1492-XIM4024-16R

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

3.27 in.(83 mm)

2.78 in.(70.5 mm)

4.72 in.(120 mm)

6.30 in.

(160 mm)

2.19 in.

(55.5 mm) 1.67 in.(42.5 mm)

3.27 in.

(83 mm)

2.78 in.

(70.5 mm)

2.37 in.

(60.2 mm)

3.27 in.

(83 mm)

9.06 in.

(230 mm)

2.78 in.

(70.5 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 159: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 159

Digital XIM Dimensions, Continued

Cat. Nos. 1492-XIM2024-8R, 1492-XIM20120-8R

Cat. Nos. 1492-XIM24-8R, 1492-XIM120-8R

Cat. No. 1492-XIMF-2

Cat. Nos. 1492-XIMF-F24-2, 1492-XIMF-F120-2

2.19 in.

(55.5 mm) 1.67 in.

(42.5 mm)

3.27 in.

(83 mm)

6.30 in.

(160 mm)

2.78 in.

(70.5 mm)

2.37 in.

(60.2 mm)1.67 in.

(42.5 mm)

3.27 in.

(83 mm)

6.30 in.

(160 mm)

2.19 in.

(55.5 mm)

3.15 in.

(80 mm)

2.19 in.

(55.5 mm) 1.67 in.

(42.5 mm)

3.27 in.

(83 mm)

3.15 in.

(80 mm)

2.19 in.

(55.5 mm) 1.67 in.

(42.5 mm)

3.27 in.

(83 mm)

2.28 in.

(58 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 160: Prog Controller Wiring Systems

160 Digital/Analog Programmable Controller Wiring Systems

AIFM DimensionsCat. No. 1492-AIFM4-3

Cat. Nos. 1492-AIFM6S-3, 1492-AIFM6TC-3

Cat. Nos. 1492-AIFM4C-F-5, 1492-AIFM4I-F-5

Cat. No. 1492-AIFM8-3

3.27 in.(83 mm)

2.74 in.(69.5 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

2.36 in.(60 mm)

3.15 in.(80 mm)

3.27 in.(83 mm)

2.74 in.(69.5 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 in.)

3.15 in.(80 mm)

3.27 in.(83 mm)

2.74 in.(69.5 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 in.)

3.27 in.(83 mm)

2.74 in.(69.5 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

4.33 in.(110 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 161: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 161

AIFM Dimensions, Continued Cat. Nos. 1492-AIFM8-F-5, 1492-AIFM16-F-3, 1492-AIFMQS, 1492-AIFMPI

Cat. No. 1492-AIFM16-F-5

3.27 in.(83 mm)

2.74 in.(69.5 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

4.72 in.(120 mm)

3.27 in.(83 mm)

2.74 in.(69.5 mm)

2.19 in.(55.5 mm)

1.67 in.(42.5 mm)

8.27 in.(210 mm)

Publication 1492-TD008A-EN-P - March 2001

Page 162: Prog Controller Wiring Systems

162 Digital/Analog Programmable Controller Wiring Systems

Marking Systems Pre-Printed and Blank Adhesive Label Cards

All Bulletin 1492 IFMs, XIFMs, and AIFMs come with an adhesive label card. The label card provides the field-side connection descriptions for the programmable controller I/O module. The label strips basically copy the wiring descriptions from the I/O module in the chassis down to the Interface Module terminals on the DIN Rail.The label cards list all of the compatible I/O modules and their respective wiring descriptions. Depending on the I/O module that is used, the label strip(s) are simply peeled from the label card and applied to the field-side terminals on the Interface Module. Refer to the respective I/O Module Product Data for actual wiring connections and recommendations.Labels are provided in the octal and decimal numbering systems for Bulletin 1746 I/O modules. Labels for Bulletin 1771 I/O modules are supplied in the octal numbering system, like the I/O modules themselves. Labels for Bulletin 1756 and 1769 I/O modules are supplied in the decimal numbering system, like the I/O modules. Interface Modules with LEDs or fuse clips come with the LEDs or fuse clips/blown fuse indicators numbered in decimal. LED and fuse labels are also provided in octal for use with Bulletin 1771 I/O modules. The LED or fuse conversion label(s) are placed directly on the circuit board of the Interface Module. For extra terminal modules, pre-printed labels are provided to identify the power bus(ses) or commoned terminals (middle and/or lower rows of terminals) on the Interface Module. For each I/O module, corresponding labels with L1, L2, COM, or +V are provided. The labels indicate isolated power busses or grouped commons with a different letter or number. For example, L1-A, L1-B, L1-C or COM1, COM2, COM3, etc.In addition, if generic numbering of the field-side terminals is desired, numeric labels are provided. Examples: 120, 140, and evens and odds. For write-on identification, the label cards contain blank label strips (for field-side terminals) and rectangular boxes (for the large group marking area on each IFM, XIFM, or AIFM).All of the available labels are shown on pages 163198. This information is helpful for determining field-side wiring layouts prior to installation.An example of how the labels are applied is shown below:

Publication 1492-TD008A-EN-P - March 2001

Page 163: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 163

Marking Systems, Continued

Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20F, -IFM20D24, and -IFM20D120

Publication 1492-TD008A-EN-P - March 2001

Page 164: Prog Controller Wiring Systems

164 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20F, -IFM20D24, and -IFM20D120

Publication 1492-TD008A-EN-P - March 2001

Page 165: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

Digital/Analog Programmable Controller Wiring Systems 165

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM40F and -IFM40D24

Page 166: Prog Controller Wiring Systems

166 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20D120-2, -IFM20F-F-2, -IFM20F-F24-2, -IFM20F-F120-2, and -IFM20D240-2

Publication 1492-TD008A-EN-P - March 2001

Page 167: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 167

Marking Systems, Continued

Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20D120-2, -IFM20F-F-2, -IFM20F-F24-2, -IFM20F-F120-2, and -IFM20D240-2

Publication 1492-TD008A-EN-P - March 2001

Page 168: Prog Controller Wiring Systems

168 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20F-F-2, and -IFM20F-F24-2

MODULE LABEL LEVELI/O CAT. NO.

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15

COM2

COM2

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 L2 L21769-IA16

1769-IQ16 SINK

1769-IQ16 SOURCE

45006-237-01 (A)

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

L11

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15

OUT1

OUT3

OUT5

OUT9

OUT11

OUT13

OUT15

VDC2

VDC2

VDC1

VDC1

+VDC

L2 L2

COM1

COM1

OUT0

L11

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

L12

L12

1769-OA8. -OW8 (AC)

1769-OW8 (DC)

1769-OB16

1769-OV16

NUMERIC

LED LABEL

FUSE LABEL

3 4 5 61 2 7 8 9 10 11 12 13 14 15 16 17 18 19 20

25 26 27 28 29 30 32 33 34 35 36 37 38 39 40

5 7 9 111 3 13 15 17 19 21 23 25 27 29 33 35 37 39

6 8 10 122 4 14 16 18 20 22 24 26 28 30 32 34 36 38

00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17

L1 L1

+VDC1

+VDC2

COM1

COM2

L21

L22

+VDC1

OUT0

+VDC1

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

+VDC2

+VDC2

COM1

COM2

OUT7

OUT0+VDC OUT

2OUT

4OUT

6OUT

8OUT10

OUT12

OUT14 COM COM

COM COM

OUT1

OUT3

OUT5

OUT9

OUT11

OUT13

OUT15+VDC OUT

7OUT

0+VDC OUT2

OUT4

OUT6

OUT8

OUT10

OUT12

OUT14 COM COM

+VDC +VDC

01 02 03 0400 05 06 07 10 11 12 13 14 15 16 17

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

40

31

Publication 1492-TD008A-EN-P - March 2001

Page 169: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 169

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM20F-F240-2, -IFM20F-FS120-4, and -IFM20F-FS240-4

MODULE LABELI/O CATATA . NO.

45006-110-01 (E)

LEVEL

Upper

Lower

Lower

Upper

Upper

Upper

Lower

Lower

Lower

Lower

Upper

Lower

Upper

Upper

Upper

Upper

Lower

Lower

L20

L21

L22

L23

L24

L25

L26

L27

L10

L11

L12

L13

L14

L15

L16

L17

COM0

COM1

COM2

COM3

COM4

COM5

COM6

COM7 +V0 +V1 +V2 +V3 +V4 +V5 +V6 +V7

L20

L20

L20

L20

L21

L21

L21

L21

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

L20

L21

L22

L23

L21

L21

L21

L21

L21

L21

L24

L25

L26

L27

L22

L22

L22

L22

L22

L22

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

COM0

COM1

COM2

COM3

COM4

COM5

COM6

COM7

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

L20

L20

L20

L20

L21

L21

L21

L21

L10

L10

L10

L10

L11

L11

L11

L11

+VDC2

COM2

COM2

COM2

+VDC2

COM2

COM2

COM2

1 2 3 4 5 6 7 8

1746-OW16 (DC)

1756-OA8, -OA8D, -OA8E TC-ODC081, TC-ODX081

1756-OA16TC-ODA161

1746-OX8 (AC)

NUMERIC

1746-OX8 (DC)

1746-OA16,1746-OW16 (AC)

1771-OMD

LED LABEL

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

L11

L11

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

OUT9

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

L12

L12

L11

L11

OUT00

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT07

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17

L12

L12

L21

L22

L10

L20

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

OUT9

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

L11

L21

L20

L21

Upper1769-OA8,-OW8 (AC)

L11

L12

L11

COM1

COM1

COM1

COM1

COM1

COM1

+VDC1

+VDC1

L12

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

L2 L2

+V1 +V1 OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

OUT9

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15 +V2 +V2

+V1 +V1 OUT00

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT07

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17 +V2 +V2

L1 L1 OUT00

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT07

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17 L1 L2

COM1

COM2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

21 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

Upper1769-OW8 (DC)

1769-OW8I (AC)

1769-OW8I (DC)

Publication 1492-TD008A-EN-P - March 2001

Page 170: Prog Controller Wiring Systems

170 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. No. 1492-IFM20D24A-2, -IFM20D120A-2, and -IFM20D240A-2

4500

6-08

6-01

(D)

LED

LABE

L

34

56

12

78

910

1112

1314

1516

0010

1112

1314

1516

17

12

34

56

78

910

1112

1314

1516

1718

1920

3233

3435

3637

3839

40

2325

2729

3133

3537

39

224

2628

3032

3436

3840

NUM

ERIC

0001

0203

0405

0607

1011

1213

1415

1617

FUSE

LAB

EL

0102

0304

0005

0607

1011

1213

1415

1617

23

45

16

78

910

1112

1314

1516

MOD

ULE

LABE

LI/O

CATATA

. NO.

ININ

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

L2L2

IN 00IN

ININ 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

L2L2

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

COM

COM

1746

-IA16

, IM

16,

IN16

(AC)

1746

-IB16

,IN

16 (D

C),

ITB1

6

1746

-IV16

, ITV

16

IN 00IN 01

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

COM

COM

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

+V+V

IN 00IN 01

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

+V+V L2

IN 0IN 1

L2 0L2 0

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

L2 1L2 1

1769

-IM12

IN 1 0

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN

L2IN 01

00IN 02

IN 03IN 04

IN 05IN 06

IN 07IN 10

IN 11IN 12

IN 13IN 14

IN 15IN 16

IN 17IN

L1

L217

71-IM

D01

00IN 02

IN 03IN 04

IN 05IN 06

IN 07IN 10

IN 11IN 12

IN 13IN 14

IN 15IN 16

IN 17IN

1756

-IA16

TC-ID

A161

IN 0IN 1

GND 0

GND 0

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

GND 1

GND 1

IN 0IN 1

L1 0IN 2

IN 3L2 0

L2 0L2 0

L2 0L2 1

L2 1L2 1

L2 1IN 4

IN 5IN 6

IN 7L1 1

L2 1

1756

-IB16

TC-ID

D161

1756

-IA8D

TC-ID

X081

LEVE

L

Upp

er

Upp

er

Low

er

Upp

er

Upp

er

Low

er

Upp

er

Upp

er

Low

er

Upp

er

Low

er

Low

er

Upp

er

Low

er

Low

er

Upp

er

Low

er

Upp

er

Low

er

Upp

er

Upp

er

Upp

er

Low

er

CO

M

L1 L1

IN 0IN 1

L2 0L2 0

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

L2 1L2

L2L2

L2L21

1756

-IN16

L1

+D

C

+V

L1L1 L1 L1

1769

-IA16

Upp

er

Low

erL1

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

COM

COM

COM

COM

1769

-IQ16

SIN

KU

pper

Low

er+

VD

C+

VD

C

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

+VDC

+VDC

+VDC

++VDC

++VDC

+17

69-IQ

16SO

URCE

Upp

er

Low

erC

OM

CO

M

COM

0100

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

IN+V

COM

1771

-IBD,

ICD

0100

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

IN

Upp

er

Low

er

Upp

er

Low

er+

V+V

1771

-IND

(DC)

1771

-IAD,

IND

(AC)

L2

Publication 1492-TD008A-EN-P - March 2001

Page 171: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 171

Marking Systems, Continued

Adhesive Label Card for Cat. No. 1492-IFM20F-3 (Series B)

Publication 1492-TD008A-EN-P - March 2001

Page 172: Prog Controller Wiring Systems

172 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM40F-2, -IFM40D24-2, -IFM40D24A-2, -IFM40D120-2, -IFM40D120A-2, -IFM40F-F-2, -IFM40F-F24-2, and -IFM40F-F120-2

Publication 1492-TD008A-EN-P - March 2001

Page 173: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 173

Marking Systems, Continued

Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM40F-2, -IFM40D24-2, -IFM40D24A-2, -IFM40D120-2, -IFM40D120A-2, -IFM40F-F-2, -IFM40F-F24-2, and -IFM40F-F120-2

GROUP 3 INPUTS

Publication 1492-TD008A-EN-P - March 2001

Page 174: Prog Controller Wiring Systems

174 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20FN, -IFM20D24N, and -IFM20D120N

MODULE LABELI/O CAT. NO. LEVEL

1746-IA16, IN16 (AC) Upper

Lower

Upper

Upper

Lower

Lower

Upper

Lower

Upper

1746-IB16, IC16,IH16, IN16 (DC), ITB16

1746-IG16

1746-OB16, OB16E,OBP16, OG16,OV16, OVP16

1746-IV16, ITV16

1746-OW16 (DC)

1746-OX8 (AC)

1746-OX8 (DC)

1746-OA16, OW16 (AC)1771-OAD, OND

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 L2

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7 L2

IN10

IN11

IN12

IN13

IN14

IN15

IN16

IN17 L2

IN00

IN01

IN02

IN03

IN04

IN05

IN06

IN07 L2

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 COM

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7 COM

IN10

IN11

IN12

IN13

IN14

IN15

IN16

IN17 COM

IN00

IN01

IN02

IN03

IN04

IN05

IN06

IN07 COM

+V IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 COM

+V IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7 COM

+V IN10

IN11

IN12

IN13

IN14

IN15

IN16

IN17 COM

L1 OUT00

L1 OUT0

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT07 L1

+V OUT8

OUT9

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15 COM

+V IN00

L1 OUT8

IN01

IN02

IN03

IN04

IN05

IN06

IN07 COM

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 +V

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7 +V

IN10

IN11

IN12

IN13

IN14

IN15

IN16

IN17 +V

IN00

IN01

IN02

IN03

IN04

IN05

IN06

IN07 +V

+V OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7 +V

+V OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17 COM

+V OUT00

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT07 +V

OUT4

L14

OUT5

L15

OUT6

L16

OUT7

L17

L11

OUT1

L10

OUT0

L12

OUT2

L13

OUT3

OUT4 +V4 OUT

5 +V5 OUT6 +V6 OUT

7 +V7

+V1 OUT1+V0 OUT

0 +V2 OUT2 +V3 OUT

3

OUT9

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15 L2

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7 L1

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17 L2

Lower

Upper

Lower

Upper+V OUT8

OUT9

OUT10

OUT11

OUT12

OUT13

OUT14

OUT15 COM

+V OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7 COM

+V OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17 COM

+V OUT00

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT07 COM

Lower

Lower

Upper

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Lower

Upper

Upper

Lower

Upper

Lower

Upper

Lower

L1 OUT10

L21

L21

L10

L21

L21

IN4

IN5

IN6

IN7

L21

IN0

IN1

IN2

IN3

L20

L20

L20

L20

L11

1756-IA8DTC-IDX081

44006-274-02 (D)

LED LABEL

NUMERIC

1771-IAD (AC),IND (AC)

1771-IAD (DC),IND (DC)

1771-IGD

1771-OBD, OGD

1771-IBD, ICD

+V IN10

IN11

IN12

IN13

IN14

IN15

IN16

IN17 COM

+V IN00

IN01

IN02

IN03

IN04

IN05

IN06

IN07 +V

+V OUT10

OUT11

OUT12

OUT13

OUT14

OUT15

OUT16

OUT17 COM

+V OUT00

OUT01

OUT02

OUT03

OUT04

OUT05

OUT06

OUT 07 +V

1 2 3 4 5 6 7 8 9 10

1 3 5 7 9 11 13 15 17 19

2 4 6 8 10 12 14 16 18 20

11 12 13 14 15 16 17 18 19 20

IN10

IN10

IN11

IN12

IN13

IN14

IN15

IN16

IN17 L2

IN11

IN12

IN13

IN14

IN15

IN16

IN17 COM

IN01

IN02+V IN

00IN03

IN04

IN05

IN06

IN07

IN01

IN02L1 IN

00IN03

IN04

IN05

IN06

IN07

IN01

IN02

IN00

IN03

IN04

IN05

IN06

IN07

10 11 12 13 14 15 16 17

00 01 02 03 04 05 06 07

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Lower

Upper

Lower

Upper

Lower

Upper

IN11

IN14

IN15

IN12

IN13

IN16

IN17 COMIN

10

IN9

IN10

L20

IN8

IN11

IN12

IN13

IN14

IN15

L21

IN1

IN2

L20

IN0

IN3

IN4

IN5

IN6

IN7

L21

IN9

IN10

GND0

IN8

IN11

IN12

IN13

IN14

IN15

GND1

IN1

IN2

GND0

IN0

IN3

IN4

IN5

IN6

IN7

GND1

1756-IA16, IN16TC-IDA161

L11

L11

L20

L11

L11

OUT4

OUT5

OUT6

OUT7

L11

OUT1

OUT2

OUT0

OUT3

L10

L10

L10

L10

L21

1756-OA8D, OA8ETC-ODX081

1756-IB16, IC16TC-IDD161TC-IDE161

L11

L11

OUT0

L11

L11

OUT4

OUT5

OUT6

OUT7

L11

OUT2

OUT3

L10

OUT1

L10

L10

L10

L10

1756-OA8, ON8TC-ODC081

OUT9

OUT10

L20

OUT8

OUT11

OUT12

OUT13

OUT14

OUT15

L21

OUT1

OUT2

L10

OUT0

OUT3

OUT4

OUT5

OUT6

OUT7

L11

1756-OA16 TC-ODA161

1756-OB16ETC-ODD161

+DC1

+DC1

OUT0

+DC1

+DC1

OUT4

OUT5

OUT6

OUT7

RTN1

OUT9

OUT10

RTN0

OUT8

OUT11

OUT12

OUT13

OUT14

OUT15

RTN1

OUT2

OUT3

+DC0

OUT1

RTN0

+DC0

+DC0

+DC0

RTN0

RTN1

1756-OB8, OC8TC-ODD081TC-ODE081

OUT1

OUT2

+DC0

OUT0

OUT3

OUT4

OUT5

OUT6

OUT7

+DC1

Publication 1492-TD008A-EN-P - March 2001

Page 175: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 175

Marking Systems, Continued

Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20FN, -IFM20D24N, and -IFM20D120N

MODULE LABELI/O CAT. NO.

45006-236-01 (C)

LED LABEL

LEVEL

NUMERIC

1769-IA16 Upper

Lower

Upper

Upper

Lower

Lower

Upper

Lower

Upper

1769-OA8 (AC),-OW8

L2

L2

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 L2

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7 L2

1769-IQ16 SINK

1769-IQ16 SOURCE

COM1

COM1

+VDC1

+VDC1

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15

COM2

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

COM2

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15

+VDC2

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

+VDC2

OUT4

OUT5

OUT6

OUT7

L12

OUT0

OUT1

OUT2

OUT3

L11

L12

L11

1769-OW8 (DC)

1769-OB16, -OV16

OUT4

OUT5

OUT6

OUT7

+VDC2

OUT0

OUT1

OUT2

OUT3

+VDC1

+VDC2

+VDC1

+VDC IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15 COM

+VDC IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7 COM

1 2 3 4 5 6 7 8 9 10

1 3 5 7 9 11 13 15 17 19

2 4 6 8 10 12 14 16 18 20

11 12 13 14 15 16 17 18 19 20

10 11 12 13 14 15 16 17

00 01 02 03 04 05 06 07

Lower

Upper

Lower

1769-IA8I IN4

L24

IN5

L25

IN6

L26

IN7

L27

IN0

L20

IN1

L21

IN2

L22

IN3

L23

Upper

Lower

Publication 1492-TD008A-EN-P - March 2001

Page 176: Prog Controller Wiring Systems

176 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM20DS24-4 and -IFM20DS120-4

1 2 3 4 5 6 7 8

MODULE LABEL LEVEL

UPPER

DC0

DC1

DC2

DC3

DC4

DC5

DC6

DC7

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

COM0

COM0

COM1

COM1

COM2

COM2

COM3

COM3

COM4

COM4

COM5

COM5

COM6

COM6

COM7

COM7

COM0

COM0

COM0

COM0

COM0

COM0

COM0

COM0

COM1

COM1

COM1

COM1

COM1

COM1

COM1

COM1

OUT7

COM1

COM1

COM1

COM1

COM1

COM1

COM1

COM1

COM2

COM2

COM2

COM2

COM2

COM2

COM2

COM2

0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7L1 L1 L1 L1 L1 L1 L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT

0 0 0 0 1 1 1 1 0 1 2 3 4 5 6 7L1 L1 L1 L1 L1 L1 L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT

0 0 0 0 1 1 1 1 0 1 2 3 4 5 6 7L1 L1

0 0L1 L1

0 0RTN RTN

0 0RTN RTN

1 1RTN RTN

1 1RTN

2L1

RTN

L1 L1 L1 L1 L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT1

L1

0 0 0 0 1 1 1 1 0 1 2 3 4 5 6 7+DC +DC +DC +DC +DC +DC +DC +DC OUT OUT OUT OUT OUT OUT OUT OUT

L20

L20

L21

L21

L22

L22

L23

L23

L24

L24

L25

L25

L26

L26

L27

L2 7

L20

L20

L20

L20

L20

L20

L20

L20

L21

L21

L21

L21

L21

L21

L21

L21

L21

L21

L21

L21

L21

L21

L21

L22

L22

L22

L22

L22

L22

L22

L2 1

L2 2

OUT7

L20

L20

ZCL200

L20

L20

L20

L20

L20

L20

L21

L21

L21

L21

L21

L21

L21

L2 1

I/O CAT. NO.

1746-OX8 (AC)

1746-OX8 (DC)

1756-OA8D,1756-OA8E,TC-ODX081

1756-OB8, -OC8,TC-ODD081,TC-ODE081

1756-OA8,1756-ON8,TC-ODC081

LOWER

UPPER

LOWER

UPPER

LOWER

UPPER

LOWER

UPPER

LOWER

1L1

1L1

2L1

1769-OA8 (AC),-OW8

UPPER

LOWER

1+VDC

1+VDC

2+VDC

2+VDC

1769-OW8 (DC) UPPER

LOWER

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

NUMERIC

LED

45006-056-01 (E)

ZCL211

1L1

1769-OW8I (AC)

1769-OW8I (DC)

0 1 2 3 4 5 6OUT OUT OUT OUT OUT OUT OUT

0 1 2 3 4 5 6OUT OUT OUT OUT OUT OUT OUT

Publication 1492-TD008A-EN-P - March 2001

Page 177: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 177

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM20F-FS-2, -IFM20F-FS24-2, and -IFM20F-FS120-2

MODULE LABELI/0 CAT. NO.

1746-OX8 (AC)

1746-OX8 (DC)

1769-OA8 (AC),OW8

1756-OA8D1756-OA8ETC-ODX081

LED LABEL

45006-022-01 (D)

NUMERIC

1756-OB81756-OC8TC-ODD081TC-ODE081

LEVEL

UPPER0 1 2 3 4 5 6 7

0L1

0L2

1L1 2L1 3L1 4L1 5L1 6L1 7L1

R0 0 1 2 3 4 5 6 7

+V0R0 +V0 +V0 +V0 +V1 +V1 +V1 +V1

R1

R1

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7

11 12 13 14 15 16 17 18 19 20

1 3 5 7 9 11 13 15 17 19

2 4 6 8 10 12 14 16 17 20

LOWER

UPPER0 1 2 3 4 5 6 7

+V0 +V1 +V2 +V3 +V4 +V5 +V6 +V7 LOWER

UPPER

LOWER

UPPER

LOWER

0 1 2 3 4 5 6 7

0L1 0L1 0L1 0L1 1L1 1L1 1L1 1L1 1L2

L11

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

L12

L11

L12

0L1

0L1 0L1 0L1 0L1 1L1 1L1 1L1 1L1

1L1 UPPER0 1 2 3 4 5 6 7

LOWER

UPPER

LOWER

UPPER

LOWER

1769-OW8 (DC) +VDC1

OUT0

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

+VDC2

+VDC1

+VDC2

UPPER

LOWER

8

1756-OA81756-ON8TC-ODC081

1769-OW8I (AC)

1769-OW8I (DC)

Publication 1492-TD008A-EN-P - March 2001

Page 178: Prog Controller Wiring Systems

178 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM20F-FS24A-4 and -IFM20F-FS120A-4

1 2 3 4 5 6 7 8

MODULE LABEL LEVEL

UPPERL20

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

L10

0 1 2 3 4 5 6 7

L21

L10F

L10F

L10F

L10F

L11F

L11F

L11F

L11F

L11

0F 1F 2F 3F 4F 5F 6F 7F

COM IN IN IN IN IN IN IN IN +DC

COM +DC +DC +DC +DC

I/O CAT. NO.1756-IA8DTC-IDX081

1771-IB, -IH, -IT

LED

45006-120-01 (B)

LOWER

UPPER

LOWER

1 3 4 5 6 7 8 9 10 11 12 13 14

21 22 23 24 25 26 27 28

5 7 9 13 15 17 19 21 23 25 27

2 4 6 8 12 14 16 18 20 22 24 26 28

NUMERIC

0 1 2 3 4 5 6 7

OF 1F 2F 3F 4F 5F 6F 7F

L2 IN IN IN IN IN IN IN IN L1

L2 L1 L1 L1 L1 L1 L1 L1 L1 L1

1771-IA, -IA2,-IN (AC) UPPER

LOWER

1771-IA, IA2,-IN (DC)

Publication 1492-TD008A-EN-P - March 2001

Page 179: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 179

Marking Systems, Continued

Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20D24-3, -IFM40F-3, and -IFM40D24-3

Publication 1492-TD008A-EN-P - March 2001

Page 180: Prog Controller Wiring Systems

180 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20D24-3, -IFM40F-3, and -IFM40D24-3

Publication 1492-TD008A-EN-P - March 2001

Page 181: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 181

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. Nos.1492-IFM20F-F24A-2 and -IFM20F-F120A-2

MOD

ULE

LABE

LI/O

CATATA

. NO.

IN16

(DC)

, ITB

16

1746

-IA16

,IN

16 (A

C)

1756

-IB16

TC-ID

D161

1769

-IQ16

SINK

ING

1756

-IA16

, IN1

6TC

-IDA1

61

1771

-IAD

(AC)

IND

(AC)

LEVE

L

Uppe

r

U ppe

r

Low

er

Low

er

Uppe

r

L ow

er

Uppe

r

L ow

er

Uppe

r

L ow

er

Low

er

Low

er

Uppe

r

U ppe

r

L ow

er

Uppe

r

L ow

er

Uppe

r

Uppe

r

L ow

er

Low

er

Uppe

r

1771

-IBD,

ICD

1771

-IAD

(DC)

IND

(DC)

ININ

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

L1 00F

L1 01F

L1 02F

L1 03F

L1 04F

L1 05F

L1 06F

L1 07F

L1 10F

L1 119F

L1 12F

L1 13F

L1 14F

L1 15F

L1 16F

L1 17F

IN 00IN 01

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

+V 00F

+V 01F

+V 02F

+V 03F

+V 04F

+V 05F

+V 06F

+V 07F

+V 10F

+V 119F

+V 12F

+V 13F

+V 14F

+V 15F

+V 16F

+V 17F

6F7F

8F9F

13F

14F

15F

ININ

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

L1 5FL1 6F

L1 7FL1 8F

L1 9FL1

L1L1 12

FL1 13

FL1 14

FL1 15

F

IN 00IN 01

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

IN 00IN 01

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

+V 00F

+V 01F

+V 02F

+V 03F

+V 04F

+V 05F

+V 06F

+V 07F

+V 10F

+V 11F

+V 12F

+V 13F

+V 14F

+V 15F

+V 16F

+V 17F

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

COM

COM

IN 00IN 01

IN 02IN 03

IN 04IN 05

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

+V 0F+V 1F

+V 2F+V 3F

+V-A

+V 4F+V 5F

+V 6F+V 7F

+V 8F+V 9F

+V 10F

+V 11F

+V 12F

+V 13F

+V 14F

+V 15F

+V-B

+V 00F

+V 01F

+V 02F

+V 03F

+V-A

+V-A

+V-A

+V-A

GND 0

GND

+V

+V 04F

+V 05F

+V 06F

+V 07F

+V 10F

+V 11F

+V 12F

+V 13F

+V 14F

+V 15F

+V 16F

+V 17F

COM

+VCO

M

+V-B

+V-B

+V-B

+V-A

+V-A

+V-B

L1L2

+V-B

Low

er

Uppe

r17

69-IA

16IN

ININ 2

IN 3IN 4

IN 5IN 6

IN 7IN 8

IN 9IN 10

IN 11IN 12

IN 13IN 14

IN 15L1 0F

L1 5FL1 6F

L1 7FL1 8F

L1 9FL1

L1L1 12

FL1 13

FL1 14

FL1 15

FL1

L1L1

L1

+V-A

+V-A

+V-B

+V-B

GND 1

GND 1

+DC A

A

L2 0L2 0

+DC B

+DC B

L2 1L2 1

L2L2

L2L2

Low

er

Uppe

r17

69-O

V16

OUT

OUT

OUT

OUT

OUT

OUT 5

OUT 6

OUT 7

OUT 8

OUT 9

OUT

10OU

T11

OUT

12OU

T13

OUT

14OU

T15

+V 0F+V 6F

+V 7F+V 8F

+V 9F+V

+V+V 12

F+V 13

F+V 14

F+V 15

F+V

DC+V

DC+V

DC+V

DC

+VDC

+VDC

COM

COM

IN 0IN 1

IN 2IN 3

IN 4IN 5

IN 6IN 7

IN 8IN 9

IN 10IN 11

IN 12IN 13

IN 14IN 15

L2L2

ININ

ININ

IN 06IN 07

IN 10IN 11

IN 12IN 13

IN 14IN 15

IN 16IN 17

L2L2

L1-A

L1L1 6F

L1 7FL1 8F

L1L1

L1L1

L1 13F

L1 14F

L1

L1-B

L1-A

L1L1

L1L1

L1L1

L1L1 14

FL1 15

FL1 16

FL1 17

F

L1-B

L1-A

L1-A

L1-B

L1-B

L1-A

L1-A

L1-B

OUT

OUT

OUT

OUT

OUT

OUT 5

OUT 6

OUT 7

OUT

OUT

OUT

OUT

11OU

T12

OUT

13OU

T14

OUT

15

0607

1014

1516

+V 6F+V 7F

+V 8F+V

+V+V

+V+V 13

F+V 14

F+V

+V+V

+V+V

+V+V 14

F+V 15

F+V 16

F+V 17

F

1746

-OV1

6, O

VP16

4500

6-10

0-01

(C)

LED

LABE

L

12

34

56

78

910

1112

1314

1516

1718

1920

NUM

ERIC

12

34

56

78

1316

910

1112

1415

3336

3132

3435

3738

4039

17

925

3121

2327

2933

3539

37

26

826

3222

2428

3034

3640

38

Publication 1492-TD008A-EN-P - March 2001

Page 182: Prog Controller Wiring Systems

182 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM40DS24-4, -IFM40DS24A-4, -IFM40DS120-4, -IFM40DS120A-4, and -IFM40DS240A-4

Publication 1492-TD008A-EN-P - March 2001

Page 183: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 183

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS-2, -IFM40F-FS24-2, and -IFM40F-FS120-2

10 11 12 13 17161514

9 10 11 12 16151413

1 2 3 4 8765

00 01 02 03 07060504

Publication 1492-TD008A-EN-P - March 2001

Page 184: Prog Controller Wiring Systems

184 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS24-4 and -IFM40F-FS240-4

1

00

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

01 02 03 04 05 06 07 10 11 12 13 14 15 16 17

MODULE LABEL LEVEL

UPPERL20

L21 2 4

L25

L26

L27

L28

L29

L210

L214

L215

OUT0

OUT1

OUT2 3 4 6 7

OUT8

OUT9

OUT10

OUT11

0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 0NC 0NO 1NC 1NO 2NC 2NO 3NC 3NO 4NC 4NO 5NC 5NO

12OUT15

L20 1 2 4 5

L26

L27

L28

L29 10 14

L215

L10

L11 2 3 4 6 7 8

L19

L110 11 12 15

0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 2 3 3 4 4 5 5 6 6 7

L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT6NC

OUT6NO

OUT7NC

OUT7NO

L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

0 0 1 2 2 3 3 4 4 5 5 6 7 7 0NC ONO 1NC 4NC 4NO 5NC 5NO 7NOCOM OUT OUT OUT

0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 2 3 3 4 4 5 5 6 6 7COM +DC +DC +DC

I/O CAT. NO.1756-OA16I1756-OW16I (AC)TC-ODK161TC-ORC161 (AC)1756-OB8EI

1756-OB16DTC-ODX161

1756-OX8I (AC)TC-ORC081 (AC)

1756-OX8I (DC)TC-ORC081 (DC)

LED

45006-047-02 (D )

LOWER

UPPER

LOWER

UPPER

LOWER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68

NUMERIC

8 1 9 10

0 1 2 4 5 6 7 8 9 10 14 15 0 1 2 3 4 6 7 8 9 10 11 12 15

COM COM COM COM OUT OUT OUT OUT OUT OUT OUT OUT

COM COM COM COM +DC +DC +DC +DC +DC +DC +DC +DC

1756-OW16I (DC),-OB16ITC-ORC161 (DC),TC-ODJ161

UPPER

LOWER

0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 2 3 3 4 4 5 5RTN RTN OUT OUT OUT OUT

6 6 7

0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 3 4 4 5 5RTN RTN RTN RTN RTN RTN +DC RTN RTN +DC RTN

6RTN

0 1 0 1 9 10GND GND GND GND GND GND OUT OUT OUT OUT OUT OUT OUT

0 1 0 0 1 1GND GND GND GND GND GND +DC +DC +DC +DC +DC +DC +DC GND

UPPER

LOWER

UPPER

LOWER

00 06 07 10 11 17 00 01 02 10 11 12 13COM OUT OUT OUT

00 06 07 10 11 17 00 01 02 10 11 12 13COM COM COM COM +V +V +V +V +V +V +V

1771-OQ16 UPPER

LOWER

Publication 1492-TD008A-EN-P - March 2001

Page 185: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

Digital/Analog Programmable Controller Wiring Systems 185

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS120-4, -IFM40F-FS24A-4, and -IFM40F-FS120A-4

Page 186: Prog Controller Wiring Systems

186

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-XIM2024-8R, -XIM20120-8R, and -XIM4024-8R

Publication 1492-TD008A-EN-P - March 2001

Page 187: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 187

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-XIM24-8R and -XIM120-8R

Publication 1492-TD008A-EN-P - March 2001

Page 188: Prog Controller Wiring Systems

188 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-XIMF-F24-2, -XIMF-F120-2, and -XIMF-2

Publication 1492-TD008A-EN-P - March 2001

Page 189: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 189

Marking Systems, Continued

Adhesive Label Card for Cat. No. 1492-XIM4024-16R

Publication 1492-TD008A-EN-P - March 2001

Page 190: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

190 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-AIFM4I-F-5 and -AIFM4C-F-5

Page 191: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

Digital/Analog Programmable Controller Wiring Systems 191

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. No. 1492-AIFM4-3

MODULE LABEL LEVELUpper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Lower

Upper

Lower

I/O CAT. NO.1746-NI4

1746-NIO4I,-NIO4V, -FIO4I,-FIO4V

1746-NO4I, -NO4V

1769-IF4

1756-OF4TC-OAV041

45006-034-01 (D)

NUMERIC

2+ 2- C SH 3+ 3- C SH

0+ 0- C SH 1+ 1- C SH

0+ 0- C SH 1+ 1- C SH

2 C +V SH 3 C -V SH

0 C +V SH 1 C -V SH

9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8

1 3 5 7 9 11 13 15

2 4 6 8 10 12 14 16

2 C SH 3 C SH

0 C SH 1 C SH

2+ 2- SH 3+ 3- SH

Upper2 RTN SH 3 RTN SH

0 RTN SH 1 RTN SH

0+ 0- SH 1+ 1- SH

O/0 C SH O/1 C SH

Upper

Lower

1769-IF4 2+ SH 3+ SH

0+ SH 1+ SH

Lower

DIFF. VOLTAGEDIFF. CURRENT

SNG. END. VLTG.SNG. END. CUR.

1769-OF2SNG. END. VLTG.SNG. END. CUR.

Upper

Lower

1771-OFE 3+ 3- SH 4+ 4- SH

1+ 1- SH 2+ 2- SH

0+ COM SH 1+ COM SH

COM

Page 192: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

192 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. Nos. 1492-AIFM6S-3 and -AIFM6TC-3

Page 193: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 193

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Part 1 of Adhesive Label Card for Cat. No. 1492-AIFM8-3

MODULE LABELI/O CAT. NO.

1756-IF8TC-IAH081

1756-IF16TC-IAH161

1756-OF8TC-OAV081

LEVEL

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Upper

Lower

Upper

Lower

Upper

Lower

Lower

Upper

SINGLE ENDED VOLTAGE INPUTS

1746-NI8

1771-IFESINGLE ENDED

0 1 2 3 4 5 6 7

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

0 RTN 1 2 RTN 3 4 RTN 5 6 RTN 7

RTN

RTN

0 RTN 1 RTN 2 RTN 3 RTN 4 RTN 5 RTN 6 RTN 7 RTN

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15

OUT0 RTN OUT

1 RTN OUT2 RTN OUT

3 RTN OUT4 RTN OUT

5 RTN OUT6 RTN OUT

7 RTN

Upper

Lower

Upper

Lower

0+ 0- 1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7-

SHIELD MODULE COM

SHIELD RTN

SINGLE ENDED CURRENT INPUTS

SHIELD RTN + I RTN

DIFFERENTIAL VOLTAGE INPUTS

SHIELD RTN

0 1 2 3 4 5 6 7DIFFERENTIAL CURRENT INPUTS

SINGLE ENDED VOLTAGE INPUTS

SINGLE ENDED CURRENT INPUTS

DIFFERENTIAL VOLTAGE INPUTS

DIFFERENTIAL CURRENT INPUTS

SHIELD RTN

SHIELD RTN

SHIELD RTN + I RTN

SHIELD RTN

SHIELD RTN

SHIELD RTN

COMSHIELD

LowerSHIELD RTN

1746-NI16V Upper

Lower

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

COMSHIELD

COMSHIELD

Upper

Lower

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 151746-NI16I SINGLE ENDED CURRENT INPUTS

SINGLE ENDED VOLTAGE INPUTS

Publication 1492-TD008A-EN-P - March 2001

Page 194: Prog Controller Wiring Systems

194 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Part 2 of Adhesive Label Card for Cat. No. 1492-AIFM8-3

45006-019-01 (D)

1771-IL

NUMERIC

1771-IFEDIFFERENTIAL

Upper

Upper

Lower

Lower

Upper

Lower

Upper

Lower

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32

1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7- 8+ 8-

1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7- 8+ 8-

MODULE COM

COM

SHIELD

SHIELD

Publication 1492-TD008A-EN-P - March 2001

Page 195: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 195

Marking Systems, Continued

Adhesive Label Card for Cat. No. 1492-AIFM8-F-5

Publication 1492-TD008A-EN-P - March 2001

Page 196: Prog Controller Wiring Systems

196 Digital/Analog Programmable Controller Wiring Systems

Marking Systems, Continued

Adhesive Label Card for Cat. No. 1492-AIFM16-F-3

MODULE LABELI/O CATATA . NO.

1756-IF16TC-IAH161

1771-IFESINGLE ENDED

45006-107-01 (C)

LEVEL

NUMERIC

LED LABEL

Upper

Middle

Middle

Middle

Middle

Middle

1+V 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 COM

SHIELD

SHIELD Lower

Middle

Lower

Upper

+V2F

+V3F

+V4F

+V5F

+V0F

+V1F

+V6F

+V7F

+V8F

+V10F

+V11F

+V12F

+V13F

+V9F

+V14F

+V15F

+V RTN

+V RTN

+V RTN

+V 8 RTN

+V RTN+

V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52

33 3417

1746-NI16I Upper

Middle

Lower

Upper

Middle

Lower

+V2F

+V3F

+V4F

+V5F

+V0F

+V1F

+V6F

+V7F

+V8F

+V10F

+V11F

+V12F

+V13F

+V9F

+V14F

+V15F

1 2 3 4+V 0 5 6 7 9 10 11 128 13 14 15 COM

1746-NI16V +V2F

+V3F

+V4F

+V5F

+V0F

+V1F

+V6F

+V7F

+V8F

+V10F

+V11F

+V12F

+V13F

+V9F

+V14F

+V15F

1 2 3 4+V 0 5 6 7 9 10 11 128 13 14 15 COM

SHIELD

SHIELD

15 15 15 15

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Publication 1492-TD008A-EN-P - March 2001

Page 197: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001

Digital/Analog Programmable Controller Wiring Systems 197

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. No. 1492-AIFM16-F-5

Page 198: Prog Controller Wiring Systems

198 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued

Adhesive Label Card for Cat. No. 1492-AIFMQS

Publication 1492-TD008A-EN-P - March 2001

Page 199: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 199

Marking Systems, Continued

Adhesive Label Card for Cat. No. 1492-AIFMPI

MODULE LABEL LEVEL

UPPER

IN+1

IN-1

IN+2

IN-2

IN+3

IN-3

V0RTN

IN+4

IN-4

IN+5

IN-5

IN+6

IN-6

IN+7

IN-7

V1RTN

SH +V0F

IN+0

IN-0

OUT0

OUT1

RTN0

RTN1

SH +V1F

SH +V2F

SH +V3F

V0+24

SH +V4F

SH +V5F

SH +V6F

SH +V7F

V1+DC

I/O CAT. NO.

1757-PIMTC-MDP081

LOWER

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

NUMERIC

45006-270-01 (A)

Publication 1492-TD008A-EN-P - March 2001

Page 200: Prog Controller Wiring Systems

200 Digital/Analog Programmable Controller Wiring Systems

Digital/Analog Programmab le Controller Wiring SystemsAccessories

Replacement Fuse Holders

IFM

The 1492-IFMFH1 fuse holders accommodate either a 5 x 20 mm fuse or the Cat. No. 1492-ISOSW-1 isolation switch plug and reside in the IFM or AIFM under normal operation. All of the fusible Bulletin 1492 IFMs and AIFMs come standard with fuse holders (for the number of fuse holders included, refer to the specifications for each IFM or AIFM). Most IFMs come with 20 fuse holders; 10 fuse holders are included with Cat. Nos.:

40 fuse holders are included with Cat. Nos.:

Replacement fuse holders (Cat. No. 1492-IFMFHI) are available in packages of 20. Cat. No. 1492-IFMFHI fuse holders are not compatible with fusible expandable XIMs.

Cat. No. 1492-IFMFH1Fuse Holder

Cat. No. 1492-ISOSW-1Isolation Switch Plug

Cat. No. 1492-SJM5-10Insulated Side Jumper

• 1492-IFM20F-FS24-2 • 1492-IFM20F-F240-2• 1492-IFM20F-FS120-2 • 1492-IFM20F-FS-2• 1492-IFM20F-F-2 • 1492-IFM20F-FS24A-4• 1492-IFM20F-F24-2 • 1492-IFM20F-FS120-4• 1492-IFM20F-F24A-2 • 1492-IFM20F-FS120A-4• 1492-IFM20F-F120-2 • 1492-IFM20F-FS240-4• 1492-IFM20F-F120A-2

• 1492-IFM40F-F-2 • 1492-IFM40F-FS120-2• 1492-IFM40F-F24-2 • 1492-IFM40F-FS120-4• 1492-IFM40F-F120-2 • 1492-IFM40F-FS240-4• 1492-IFM40F-FS-2 • 1492-IFM40F-FS24A-4• 1492-IFM40F-FS24-2 • 1492-IFM40F-FS120A-4• 1492-IFM40F-FS24-4

Publication 1492-TD008A-EN-P - March 2001

Page 201: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 201

Accessories, Continued Replacement Fuse Holders, Continued

AIFM

The Cat. No. 1492-IFMFH1 fuse holders accommodate a 5 x 20 mm fuse or the Cat. No. 1492-ISOSW-1 isolation switch plug and reside in the AIFM under normal operation. All of the fusible Cat. No. 1492 AIFMs come standard with the fuse holders 10 fuse holders with the Cat. No. 1492-AIFM4C-F-5, -AIFM4I-F-5, and -AIFM8-F-5 modules; 20 fuse holders with the Cat. No. 1492-AIFM16-F-3, and -AIFM16-F-5 modules. Replacement fuse holders are available in packages of 20.

Replacement Relays

The relays in the Relay Master and Relay Expander modules are replaceable. The following replacement relays must be used:

Isolation Switch Plugs

The Cat. No. 1492-ISOSW-1 is an isolation switch or dummy fuse in a 5 x 20 mm fuse form factor. The isolation switch plugs will fit into the Cat. No. 1492-IFMFH1 fuse holders. If fusing is not desired on a fusible IFM or AIFM, the Cat. No. 1492-ISOSW-1 isolatin switch can be used to provide feed-through functionality under normal operation and isolation switch functionality once power has been removed from the circuit. The isolation switch can then be opened for maintenance and troubleshooting. Metering equipment can also be inserted into a two-wire transmitter circuit to measure input loop current. The Cat. No. 1492-ISOSW-1 isolation switch plugs are available in packages of four.

Replacement Relays

XIM Cat. No. Replacement Relay Cat. No.

1492-XIM4024-16R 700-HK36Z24

1492-XIM4024-8R 700-HK36Z24

1492-XIM2024-8R 700-HK36Z24

1492-XIM20120-8R 700-HK36A1

1492-XIM24-8R 700-HK36Z24

1492-XIM120-8R 700-HK36A1

Publication 1492-TD008A-EN-P - March 2001

Page 202: Prog Controller Wiring Systems

202 Digital/Analog Programmable Controller Wiring Systems

Accessories, Continued Insulated Side Jumpers

The Cat. No. 1492-SJM5-10 is a 10-pole comb-style insulated side jumper. A side cutter can be used to cut the 10-pole jumper into smaller pole assemblies. The jumper fits the field-side terminal spacings on all of the Bulletin 1492 IFMs and AIFMs. Use of this jumper is a convenient means of connecting unused inputs together on the feed-through. The Cat. No. 1492-SJM5-10 insulated side jumpers are available in packages of 10.

Web Site Information Visit the following web sites for I/O wiring diagrams of the Interface Modules and cables:

• for Bulletin 1746 I/O platform:http://www.ab.com/catalogs/b113/slc/wiring.html

• for Bulletin 1756 I/O platform:http://www.ab.com/catalogs/b113/controllogix/wiring.html

• for Bulletin 1771 I/O platform:http://www.ab.com/catalogs/b113/plc5/wiring.html

• For Bulletin 1769 I/O platform:http://www.ab.com/catalogs/b113/micro1500/wiring.html

To locate the wiring diagram, navigate to one of the above platform sections of the web site and locate the desired product selection table. Select the desired I/O module, Interface Module, and pre-wired cable combination. A letter will appear in the box for all valid combinations. Wiring diagrams can be located by clicking on the underlined letter in the box.

Publication 1492-TD008A-EN-P - March 2001

Page 203: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 203

Quick Reference

Digital IFM Specifications

Digital IFMCat. No.

VoltageRange

Dimensions (L x W x H) (in.)

Indicator Circuit Current (Nominal)

No. Terminals per Device Common

Label CardCat. No.

1492-IFM20F 0…264V AC/DC 4.33 x 3.27 x 2.78 — — 43006-253-011492-IFM20FN 0…132V AC/DC 2.36 x 3.27 x 2.78 — — 44006-274-02, 45006-236-011492-IFM20F-2 0…264V AC/DC 4.33 x 3.27 x 2.78 — 10 43006-253-03, 45006-237-011492-IFM20F-3 0…132V AC/DC 4.33 x 3.27 x 2.78 — 17, 18 45006-077-011492-IFM20D24 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 1 43006-253-011492-IFM20D24N 10…30V AC/DC 2.36 x 3.27 x 2.78 2 mA 1 44006-274-02, 45006-236-011492-IFM20D24-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 10 43006-253-03, 45006-237-011492-IFM20D24A-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 20 45006-086-011492-IFM20DS24-4 10…60V AC/DC 4.33 x 3.27 x 2.78 4.1 mA 2 45006-056-011492-IFM20D24-3 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 18 43006-253-041492-IFM20D120 85…132V AC/DC 4.33 x 3.27 x 2.78 2.5 mA 2 43006-253-011492-IFM20D120N 85…132V AC 2.36 x 3.27 x 2.78 2.5 mA 1 44006-274-02, 45006-236-011492-IFM20D120-2 85…132V AC 4.33 x 3.27 x 2.78 2.5 mA 10 43006-253-03, 45006-237-011492-IFM20D120A-2 85…132V AC 4.33 x 3.27 x 2.78 2.5 mA 20 45006-086-011492-IFM20DS120-4 85…132V AC 4.33 x 3.27 x 2.78 2.6 mA 2 45006-056-011492-IFM20D240-2 204…264V AC 4.33 x 3.27 x 2.78 2.5 mA 10 43006-253-031492-IFM20D240A-2 204…264V AC 4.33 x 3.27 x 2.78 2.5 mA 20 45006-086-011492-IFM20F-F-2 0…132V AC/DC 4.33 x 3.27 x 2.78 — 10 43006-253-03, 45006-237-011492-IFM20F-F24-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 10 43006-253-03, 45006-237-011492-IFM20F-F24A-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 10 45006-100-011492-IFM20F-F120-2 85…132V AC 4.33 x 3.27 x 2.78 2.5 mA 10 43006-253-03, 45006-237-011492-IFM20F-F120A-2 85…132V AC/DC 4.33 x 3.27 x 2.78 1.2 mA — 45006-100-011492-IFM20F-F240-2 204…264V AC 4.72 x 3.27 x 2.78 1.2 mA 10 45006-110-011492-IFM20F-FS-2 0…132V AC/DC 2.36 x 3.27 x 2.78 — 1 45006-022-011492-IFM20F-FS24-2 10…30V AC/DC 2.36 x 3.27 x 2.78 2 mA — 45006-022-011492-IFM20F-FS24A-4 10…30V AC/DC 3.15 x 3.27 x 2.78 2 mA — 45006-120-011492-IFM20F-FS120-2 85…132V AC/DC 2.36 x 3.27 x 2.78 2.5 mA 1 45006-022-011492-IFM20F-FS120-4 85…132V AC/DC 4.33 x 3.27 x 2.78 2.5 mA 2 45006-110-011492-IFM20F-FS120A-4 85…132V AC/DC 3.15 x 3.27 x 2.78 2.2 mA — 45006-120-011492-IFM20F-FS240-4 204…264V AC 4.33 x 3.27 x 2.78 2.5 mA 2 45006-110-011492-IFM40F 0…132V AC/DC 4.33 x 3.27 x 2.78 — — 43006-253-021492-IFM40F-2 0…132V AC/DC 8.27 x 3.27 x 2.78 — 10 43006-253-05/061492-IFM40F-3 0…60V AC/DC 8.27 x 3.27 x 2.78 — 18 43006-253-041492-IFM40D24 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 1 43006-253-021492-IFM40D24-2 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 10 43006-253-05/061492-IFM40D24A-2 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 10 43006-253-05/061492-IFM40DS24-4 10…60V AC/DC 6.69 x 3.27 x 2.78 4.1 mA 2 45006-054-011492-IFM40DS24A-4 10…30V AC/DC 6.69 x 3.27 x 2.78 4.1 mA 2 45006-054-011492-IFM40D24-3 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 18 43006-253-041492-IFM40D120-2 85…132V AC 8.27 x 3.27 x 2.78 2.5 mA 10 43006-253-05/061492-IFM40D120A-2 85…132V AC 8.27 x 3.27 x 2.78 2.5 mA 10 43006-253-05/061492-IFM40DS120-4 85…132V AC 6.69 x 3.27 x 2.78 2.6 mA 2 45006-054-011492-IFM40DS120A-4 85…132V AC 6.69 x 3.27 x 2.78 2.6 mA 2 45006-054-011492-IFM40DS240A-4 204…264V AC 6.69 x 3.27 x 2.78 2.6 mA 1 45006-054-011492-IFM40F-F-2 0…132V AC/DC 8.27 x 3.27 x 2.78 — 10 43006-253-05/061492-IFM40F-F24-2 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 10 43006-253-05/061492-IFM40F-F120-2 85…132V AC 8.27 x 3.27 x 2.78 2.5 mA 10 43006-253-05/061492-IFM40F-FS-2 0…132V AC/DC 4.72 x 3.27 x 2.78 — 1 45006-020-011492-IFM40F-FS24-2 10…30V AC/DC 4.72 x 3.27 x 2.78 2 mA 1 45006-020-011492-IFM40F-FS24-4 10…30V AC/DC 7.09 x 3.27 x 2.78 2 mA 2 45006-047-021492-IFM40F-FS120-2 85…132V AC/DC 4.72 x 3.27 x 2.78 2.5 mA 1 45006-020-011492-IFM40F-FS120-4 85…132V AC/DC 7.09 x 3.27 x 2.78 1.4 mA 2 45006-047-011492-IFM40F-FS240-4 204…264V AC/DC 7.09 x 3.27 x 2.78 1.4 mA 2 45006-047-021492-IFM40F-FS24A-4 10…30V AC/DC 7.09 x 3.27 x 2.78 3.1 mA 1 45006-047-011492-IFM40F-FS120A-4 85…132V AC/DC 7.09 x 3.27 x 2.78 1.4 mA 1 45006-047-01

Publication 1492-TD008A-EN-P - March 2001

Page 204: Prog Controller Wiring Systems

204 Digital/Analog Programmable Controller Wiring Systems

Quick Reference, Continued

Analog IFM Specifications

Analog IFMCat. No.

VoltageRange

Dimensions (L x W x H) (in.)

Indicator Circuit Current (Nominal)

No. Terminals per Shield Common

Label CardCat. No.

1492-AIFM4-3 0…132V AC/DC 2.36 x 3.27 x 2.74 — 4 45006-034-011492-AIFM4C-F-5 10…30V DC 3.15 x 3.27 x 2.74 2 mA 4 45006-021-021492-AIFM4I-F-5 10…30V DC 3.15 x 3.27 x 2.74 2 mA 4 45006-021-021492-AIFM6S-3 0…132V AC/DC 3.15 x 3.27 x 2.74 — 6 45006-021-011492-AIFM6TC-3 0…132V AC/DC 3.15 x 3.27 x 2.74 — 6 45006-021-011492-AIFM8-3 0…132V AC/DC 4.33 x 3.27 x 2.74 — 8 45006-019-011492-AIFM8-F-5 10…30V DC 4.72 x 3.27 x 2.74 2 mA 18 44006-274-011492-AIFM16-F-3 10…30V DC 4.72 x 3.27 x 2.74 2 mA 18 45006-107-011492-AIFM16-F-5 10…30V DC 8.27 x 3.27 x 2.74 2 mA 16 45006-018-011492-AIFMQS 10…30V DC 4.72 x 3.27 x 2.74 2 mA 8 45006-018-021492-AIFMPI 0…30V DC 4.72 x 3.27 x 2.74 2 mA 8 45006-270-01

Relay Master/Expandable Interface Module Specifications

Relay Master/Expandable XIM Cat. No.

VoltageRange

Dimensions (L x W x H) (in.)

Indicator Circuit Current (Nominal)

No. Terminals per Device Common

Label CardCat. No.

1492-XIM4024-16R 20…26V DC 9.06 x 3.27 x 2.78 2 mA 16 45006-254-011492-XIM4024-8R 20…26V DC 6.30 x 3.27 x 2.78 2 mA 8 45006-142-011492-XIM2024-8R 20…26V DC 6.30 x 3.27 x 2.78 2 mA 8 45006-142-011492-XIM20120-8R 96…132V AC 6.30 x 3.27 x 2.78 2 mA 8 45006-142-011492-XIM24-8R 20…26V DC 6.30 x 3.27 x 2.78 2 mA 8 45006-143-011492-XIM120-8R 96…132V AC 6.30 x 3.27 x 2.78 2 mA 8 45006-143-011492-XIMF-2 0…132V AC/DC 3.15 x 3.27 x 2.19 2 mA — 45006-144-011492-XIMF-F24-2 10…30V DC 3.15 x 3.27 x 2.28 2 mA 8 45006-144-011492-XIMF-F120-2 85…132V AC 3.15 x 3.27 x 2.28 2 mA 8 45006-144-01

General Specifications

Cat. No. 1492-…UL/CSA Approvals UL Component Recognized, File E113724, Guide No. NRAQ2

CSA Certified, File LR1234, Class 321107, or UL Recognized per Canadian Safety Standards (cUR) (File E113724, Guide No. NRAQ2)

CE Approval —Factory Mutual Approval J.I. 3000590Maximum Peak Transient Voltage 600VMaximum Current (per circuit) 2 A (except relays)Maximum Current (per module) 12 A (except relays)Wire Range (Rated Cross Section) #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C

Publication 1492-TD008A-EN-P - March 2001

Page 205: Prog Controller Wiring Systems

Digital/Analog Programmable Controller Wiring Systems 205

Notes:

Publication 1492-TD008A-EN-P - March 2001

Page 206: Prog Controller Wiring Systems

206 Digital/Analog Programmable Controller Wiring Systems

Notes:

Publication 1492-TD008A-EN-P - March 2001

Page 207: Prog Controller Wiring Systems
Page 208: Prog Controller Wiring Systems

Publication 1492-TD008A-EN-P - March 2001 2001 Rockwell International. All Rights Reserved. Printed in USA