Upload
kyle-stack
View
111
Download
9
Tags:
Embed Size (px)
DESCRIPTION
Allen Bradley PLCs
Citation preview
Digital/Analog Programmable Controller Wiring Systems
Technical Data
Digital Wiring Systems Analog Wiring Systems
Table of ContentsDescription Page Description PageBenefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Digital (IFM/XIM and Cables)
Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Analog (AIFM and Cables)Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Ordering Digital and Analog Wiring Systems. . . . . . . . . . . . . . . . . . . . . . . . . . 23Selection Tables
Bulletin 1746 SLC 500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . 25Bulletin 1756 ControlLogix IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . 30Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Bulletin 1771 PLC-5 IFMs, XIMs, AIFMs, and Cables. . . . . . . . . . . . . . . . . . . . 40IFM-Ready I/O Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Build-to-Order Length Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
SpecificationsDigital IFMs and XIMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Digital Cables and Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Analog IFMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131Analog Cables and Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
DimensionsDigital IFM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Digital XIM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Analog IFM Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Marking SystemsDigital Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163Analog Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200Web Site Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
2 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsDescription Connecting to Allen-Bradley I/O is convenient with Allen-Bradley Interface Modules and Cables. Unlike conventional terminal blocks, they connect through pre-wired cables to digital and analog I/O for the Bulletin 1746 SLC, Bulletin 1756 ControlLogix, Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin 1771/PLC-5 platforms. The interface modules are mounted onto a standard DIN #3 Rail. Pre-printed adhesive label cards containing field-wiring information are available for each interface module and I/O module combination. Wiring systems are available for over 90 digital I/O modules and over 40 analog I/O modules.
Benefits Reduced Wiring Time
Wiring is completed in a fraction of the time when wiring systems are used as compared with the traditional method of wiring each point to the I/O swing arm and field-side terminal blocks. Pre-wired cables are factory-wired to the I/O wiring arm on one end and a connector for the Interface Module (IFM) on the other. IFMs enhance the capability of the I/O systems with added terminations, field-side LED status indicators, isolation circuits, overcurrent protection, and higher amp outputs. Both standard and specific build-to-order length cables are available, providing the correct length for any panel in a neat, space-efficient wiring solution.
Reduced Wiring Errors
Wiring system cables are pre-tested to ensure 100% accurate connections and eliminate the need for point-to-point checking of wiring. No more crossed wires and loose connections between the I/O module and the terminal block. Even one error in wiring 128 I/O points in a point-to-point system may require a complete check of the wiring. Wiring errors can take several minutes to track down and correct before the panel is ready for startup. When IFMs and cables are snapped in place, they fit every time no need to find the wrong or loose connection, resulting in a much higher rate of success at system startup.
Faster Troubleshooting and Easier Maintenance
Normal terminal blocks cant offer the benefits of IFMs, such as LED indication on each I/O point. Wiring systems improve system startup and ease troubleshooting and maintenance. Diagnostic capabilities in the form of fuses, blown fuse indication, and field-side ON-State LEDs in a reduced space allow maintenance personnel to quickly locate faults, reduce downtime, and improve overall productivity.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 3
Benefits, Continued Increased Volume and Productivity
Cable interconnections for a wiring system can be up to 30 times faster to install than traditional point-to-point wiring, enabling OEMs and panel builders using wiring systems to build panels faster and produce more machines.
Reduced Wire Preparation and Routing
Pre-wired cables eliminate the time and costs associated with stripping and cutting wires. Routing wires is much easier with wiring systems, since engineers only have to worry about routing one pre-wired cable versus the 20 or 40 wires needed in the traditional wiring method.
Labeling and Marking
Pre-printed, I/O-specific adhesive label strips for quick marking of IFM terminals save labor compared with point-to-point wiring that requires labor-intensive wire markers. Pre-wired cables require no wire labels. Pre-printed I/O-specific labels ensure neat, easy-to-read identification of wires and I/O points for all users.The marking of traditional terminal blocks has even caused some OEMs to move toward a high-tech approach of plotting markers, requiring additional equipment in the form of a plotter system and a PC to run the plotter software.
Simplified Design
Design engineers can simplify their panel drawings by calling out an IFM and pre-wired cable instead of having to detail every single wire and terminal block on their drawings. Simplified panel drawings aid not only the installer, but also the end customer who receives the panel.
Increased DIN Rail Density
An increasing trend in the industry is to pack more products into the same DIN Rail space. Wiring systems support this trend, as they require less DIN Rail space than traditional terminal blocks. For example, if an OEM were to use a 40-point IFM in place of 40 terminal blocks, DIN Rail space can be reduced by more than 50%.
Publication 1492-TD008A-EN-P - March 2001
4 Digital/Analog Programmable Controller Wiring Systems
Benefits, Continued Increased DIN Rail Density, Continued
All IFMs have terminals for connecting the I/O field wiring. In addition, extra terminal, sensor, fusible IFMs, and relay IFMs contain common terminals that are used as power busses for sensor and actuators. No additional terminal blocks are needed to provide power to the sensors/actuators saving valuable panel/DIN Rail space.To further reduce panel space, narrow IFMs (i.e., Cat. No. 1492-IFM20FN) have been designed. They require 45% less space than the standard length IFMs, making them well-suited for tightly packed enclosures. The high-density narrow IFMs have two rows of 10 field-wiring terminals with an overall length of 60 mm (2.36 in.)
Quality-Looking Panels
The pre-wired cables and IFMs organize the wiring in your panel and provide a consistent look. Pre-printed adhesive labels for the terminals neatly identify field-wiring connections, which correspond to the I/O module address. A large marking area is also available for identifying I/O information on the IFM.
Fewer Parts, Less Inventory and Lower Carrying Cost
A wiring system involves an IFM and the cable, versus the block, barrier, jumper, markers, wires, and swing arms associated with traditional hardwired systems. Therefore, it requires fewer components and, in turn, less inventory and lower carrying costs.
Design Flexibility
To develop a cost-effective system, the hardware components must meet the needs of the design engineer. Rockwell Automation provides the broadest range of digital and analog systems in the industry. Allen-Bradley Wiring Systems deliver a lower life-cycle cost.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 5
Digital IFM Options and Features
Digital IFMs, similar to groups of terminal blocks, are available with either 20-pin or 40-pin cable connectors. The number of field-side wiring terminals varies with the type of module from one to three terminals per I/O point. LEDs and fuse clips are available on-board the IFMs to customize your wiring system to your application and provide assistance with troubleshooting your control panel. The IFMs are compatible with both the pre-wired cables and the IFM-ready cables.
All of the digital IFMs have the following features:
Keyed cable connector (20- or 40-pin) with locking tabs for easy installation and secure connection of IFMs.
UL Component Recognized (File E113724 Guide NRAQ2); UL recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2); CE Approved; Factory Mutual Listed (File J.I. 3000590) FM approved.
Standard DIN #3 Rail mounting for quick installation.
Large rectangular write-on area acts as built-in group marking carrier for programmable controller rack, module group, and/or slot information.
Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.
High-density field-side wiring terminals allow more connections in less space and accommodate #22…12 AWG wire.
Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules.
Digital IFM
Publication 1492-TD008A-EN-P - March 2001
6 Digital/Analog Programmable Controller Wiring Systems
Digital IFM Options and Features, Continued
Standard Terminal Modules
Standard terminal IFM modules provide one field-side wiring terminal per programmable controller input or output point, as well as enough terminals for the I/O module power connections. The standard terminal modules are ideal for applications in which the I/O device commons are terminated in the field or remotely from the I/O module panel.
Extra Terminal Modules
Extra terminal modules provide two or four field-side terminals per input or output point. Non-isolated IFMs have two terminals per input or output. Isolated IFMs have two or four terminals per input or output. Non-isolated IFMs have the lower row of extra terminals commoned together in groups of 10 ➊ , to serve as a power bus for the field device commons. Isolated IFMs have terminals isolated into 8 or 16 groups, which allows each group of I/O devices to reference a different power source. The extra terminal modules are beneficial in applications in which the I/O devices are terminated within the same panel as the I/O modules eliminating the need for many additional terminal blocks. These modules are also available with optional field-side status LEDs for troubleshooting inputs and outputs.➊ Except Cat. Nos. 1492-IFM20D24A-2 and -IFM20D120A-2, which are in groups of 20.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 7
Digital IFM Options and Features, Continued
Sensor Modules
Sensor modules provide three field-side terminals per input point. The middle and lower rows of terminals, commoned together in groups of 18, serve as power busses for 3-wire sensor types of devices eliminating additional terminal blocks and jumpering systems. Optional field-side LEDs identify the on/off condition of the sensor signal. The sensor modules provide a compact method of terminating and powering 24V AC/DC or 120V AC (Cat. No. IFM20F-3 only) 3-wire devices.
LED Modules
Voltage-indicating LEDs are available on the standard, extra terminal, and sensor IFMs. The LEDs provide field-side troubleshooting diagnostics: the on/off status of an input device or the on/off status of the programmable controller output circuit. When used in conjunction with the logic-side programmable controller LEDs, the IFM LEDs can help determine whether a problem resides in the I/O module or field device/wiring. The LED modules have unique circuitry that allows compatibility with sinking or sourcing input or output modules.
Publication 1492-TD008A-EN-P - March 2001
8 Digital/Analog Programmable Controller Wiring Systems
Digital IFM Options and Features, Continued
Fusible Modules
Fusible modules provide a convenient method of adding overcurrent protection into your programmable controller wiring. These modules have 5 x 20 mm fuse clips on-board and are available with and without blown fuse indication. The 24V or 120V blown fuse indicators reduce the troubleshooting time to locate and replace a blown fuse on the IFM. The fusible modules have an easy-to-remove see-through acrylic cover to prevent objects from contacting fuse circuitry under normal operation. Standard fuse holders reside in the IFM, aiding in the removal of a fuse with a fuse puller (fuses are not included). The fusible modules also have two or four terminals per I/O point to create a power bus for input or output load connections. Fusible modules are available in both isolated and non-isolated versions. There are a select number of fusible IFMs available for input modules.
Relay and Expandable Modules
Relay and Expandable Interface Modules (XIM) were developed to maximize the effectiveness of users applications that require output contact ratings greater than 2 A. Driving large loads up to 10 A for applications such as motor starters is now possible with Bulletin 1492 Wiring Systems. In addition, the Relay Modules provide a means to isolate output points.The Relay and Expandable product line consists of a Relay Master module and Expander Module(s) with expander cable. The Relay Master modules provide the connection for the 20- or 40-pin cable connectors for the pre-wired cable. There are three types of expander XIMs: eight-channel relay, eight-channel fused, and eight-channel feed-through.Expander Module capabilities are offered in eight-channel increments. After using 8 or 16 channels of I/O for relays (master relay module), design engineers can use expander modules for the other I/O point needs. The flexibility means that they work with relays, fuses, and feed-through modules. In addition, the expander modules can be added when system expansion is required.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 9
Digital IFM Options and Features, Continued
Relay and Expandable Modules, Continued
Relay Master
Relay master XIMs feature field-replaceable relays with 120V or 24V rated coils. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. Other features include coil-side LED indicating the output module status, and transient suppression on each coil. The 24V relay master for 32-point outputs is offered with either 8 or 16 relays on one module.
Relay Expanders
Relay expander XIMs feature eight field-replaceable relays with 120V or 24V rated coils. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. Other features include coil-side LED indicating the output module status, and transient suppression on each coil. An expander cable is provided for connection to the mating module.
Publication 1492-TD008A-EN-P - March 2001
10 Digital/Analog Programmable Controller Wiring Systems
Digital IFM Options and Features, Continued
Relay and Expandable Modules, Continued
Fusible Expanders
The fusible expander modules feature eight 5 x 20 mm finger-safe fuse holders, blown fuse indicators, and extra terminals for landing two wires per field-side device. They are offered with eight fuse holders for both 24V and 120V applications. An expander cable is provided for connection to the mating module. Fuses are not provided.
Feed-Through Expanders
The feed-through expander modules feature eight channels with extra terminals for landing two wires per field-side device. An expander cable is provided for connection to the mating module.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 11
Digital IFM Options and Features, Continued Digital Pre-Wired Cables
Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Pre-wired cables, when used with an IFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The pre-wired cables have a removable terminal block or wiring arm at the I/O end of the cable and a cable connector on the other end to connect to the IFM. All of the pre-wired cables use #22 AWG wire and are 100% tested for continuity to make a perfect connection every time. The digital pre-wired cables are offered in four standard lengths of 0.5, 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products. Pre-wired cables are available for many of the 1746 SLC I/O, 1756 ControlLogix I/O, 1769 Compact I/O for CompactLogix and MicroLogix 1500, and 1771 PLC-5 I/O controllers.
Ready-to-Wire Digital Cables
I/O-ready cables have an I/O removable terminal block or wiring arm pre-wired to one end to of the cable and free connectors on the other end for wiring into standard terminal blocks or other type of connectors. I/O-ready cables have individual color-coded conductors for quick wire-to-terminal coordination. The I/O-ready cables use #18 AWG conductors for higher current applications or longer cable runs. The I/O-ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products. Pre-wired cables are available for the Bulletin 1746 SLC I/O, Bulletin 1756 ControlLogix I/O, Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin 1771 PLC-5 I/O controllers.
Pre-Wired Cable and Interface Module
I/O-Ready Cable and Standard Terminal Block
Publication 1492-TD008A-EN-P - March 2001
12 Digital/Analog Programmable Controller Wiring Systems
Digital IFM Options and Features, Continued
Ready-to-Wire Digital Cables, Continued
IFM-ready cables have a cable connector that attaches to the IFM pre-wired to one end and free connectors ready to wire to I/O modules or other components on the other end. IFM-ready cables use #22 AWG wire and have individual color-coded conductors for quick wire-to-terminal coordination. The digital IFM-ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products.
IFM-Ready Cable and Interface Module
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 13
IFM Cat. No. Explanation for Digital I/O Modules
Important: The following IFM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired IFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
Status IndicationF No LEDsFN Narrow IFMD24 24V LEDs for input and output modulesD24N Narrow IFM with 24V LEDsD24A 24V LEDs for input modulesDS24 Isolated IFM with 24/48V LEDs for output modulesDS24A Isolated IFM with 24V LEDs for input modulesD120 120V LEDs for input and output modulesD120N Narrow IFM with 120V LEDsD120A 120V LEDs for input modulesDS120 Isolated IFM with 120V LEDs for output modulesDS120A Isolated IFM with 120V LEDs for input modulesD240 240V LEDs for output modulesDS240A Isolated IFM with 240V LEDs for input modulesD240A 240V LEDs for input modules
Fuses and Their IndicatorsBlank No fuse clipsF 5 x 20 mm fuse clipsF24 5 x 20 mm fuse clips with 24V blown fuse
indicators for output modulesF24A 5 x 20 mm fuse clips with 24V blown fuse
indicators for input modulesF120 5 x 20 mm fuse clips with 120V blown fuse
indicators for output modulesF120A 5 x 20 mm fuse clips with 120V blown fuse
indicators for input modulesF240 5 x 20 mm fuse clips with 240V blown fuse
indicators for output modulesFS Isolated IFM with 5 x 20 mm fuse clipsFS24 Isolated IFM with 5 x 20 mm fuse clips with
24V blown fuse indicators for output modules
FS24A Isolated IFM with 5 x 20 mm fuse clips with 24V blown fuse indicators for input modules
FS120 Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indicators for output modules
FS120A Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indication for input modules
FS240 Isolated IFM with 5 x 20 mm fuse clips with 240V blown fuse indication for output modules
No. of Cable Connector Pins20 20 pins40 40 pins
Digital Interface Modules
No. of Field-Side Wiring TerminalsBlank One per I/O connection2 Two per I/O connection3 Three per I/O connection4 Four per I/O connection
1492–IFM 20 F–F120–2
Bulletin No.
Publication 1492-TD008A-EN-P - March 2001
14 Digital/Analog Programmable Controller Wiring Systems
Terms for Relay Master/Expander IFMs
Relay master and expander XIMs are available for Bulletin 1746, 1756, 1769, and 1771 digital output modules.Relay Master XIM Provides 8 or 16 relay outputs for a digital output module. Expander XIM In addition to the relay master XIM, an expander XIM provides eight additional outputs. There are three types of expander XIMs: eight-channel relays, eight-channel fusing, and eight-channel feed-through XIMs.
Relay Master/Expander XIMs Cat. No. Explanation for Digital I/O Modules
Important: The following XIM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired XIM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
1492–XIM 20 24–2
Rating of Relay Coil or Blown Fuse Indicator24 24V relay coil120 120V relay coilF No relays or fusesF-F24 5 x 20 mm fuse clips with 24V blown fuse indicatorsF-F120 5 x 20 mm fuse clips with 120V blown fuse indicators
Relay Master and Expander Interface Modules
No. Cable Connector Pins20 20 pins (master only)40 40 pins (master only)Blank Expander module
No. Relays or Extra Terminals2 2 terminals per point8R 8 relays16R 16 relays
Bulletin No.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 15
IFM and XIM Cable Cat. No. Explanation for Digital I/O Modules
Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1746, 1756, and 1771 digital I/O module cables. All combinations of these fields make valid product cat. nos. Refer to selection tables for IFM/XIM compatibility and ordering.
The cables used for Relay Master/Expander XIMs are the same as those used for Digital I/O Modules (page 23) with the exception of the Cat. No. 1746-OA16 output module, which uses the 1492-CABLE*CR cable.
➊ To make sure the Bulletin 1746 SLC 500 digital I/O module is compatible with the IFM/XIM, refer to pages 25, 26, and 27.
➋ To make sure the Bulletin 1771 PLC digital I/O module is compatible with the IFM/XIM, refer to pages 40, 41, and 42.
➌ To make sure the Bulletin 1756 ControlLogix digital I/O module is compatible with the IFM/XIM, refer to pages 30, 31, and 32.
Cable TypeA, B, C, D, E, G, N, S
Pre-wired cables for 8-channel isolated and 16-channel digital Bulletin 1746 I/O modules ➊
CR Pre-wired cable for Cat. No. 1746-OA16 (XIM only)F, T Pre-wired cable for digital Bulletin 1771 I/O modules ➋
FF Pre-wired cable with fused wiring arm for 16-channel digital Bulletin 1771 output modules ➋
H Pre-wired cable for 32-channel digital Bulletin 1746 I/O modules ➊
J, K, L, M, R Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1771 I/O modules ➋
U, V, W, X Pre-wired cables for 8- and 16-channel digital Bulletin 1756 I/O modules ➌
Y, Z Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1756 I/O modules ➌
P Digital IFM-ready cable with 20 conductorsQ Digital IFM-ready cable with 40 conductorsN3 Digital I/O module-ready cable with 40-channel Cat. No. 1746-N3
cable connectorRTBB Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25B
terminal block (blue)RTBO Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25C
terminal block (orange)RTBR Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25R
terminal block (red)TBCH Digital I/O module-ready cable with 36-channel Cat. No. 1756-TBCH
removable terminal blockTBNH Digital I/O module-ready cable with 20-channel Cat. No. 1756-TBNH
removable terminal blockWA Digital I/O module-ready cable with Cat. No. 1771-WA
8-channelwiring armWD Digital I/O module-ready cable with Cat. No. 1771-WD 6-channel
wiring armWH Digital I/O module-ready cable with Cat. No. 1771-WH 16-channel
wiring armWHF Digital I/O module-ready cable with Cat. No. 1771-WHF 16-channel
fused wiring armWN Digital I/O module-ready cable with Cat. No. 1771-WN 32-channel
wiring arm
Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001…020
0.1…2.0 m (0.328…6.56 ft)0.1 m (0.328 ft) increments
Build-to-Order
020…100
2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments
100…990
10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments
1492–CABLE 010 A
Digital Interface Cable
Bulletin No.
Publication 1492-TD008A-EN-P - March 2001
16 Digital/Analog Programmable Controller Wiring Systems
IFM and XIM Cable Cat. No. Explanation for Digital I/O Modules, Continued
Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1769 and 1771 digital I/O module cables. All combinations of these fields make valid product cat. no. Refer to selection tables for IFM/XIM compatibility and ordering.
➊ To make sure the Bulletin 1771 PLC analog I/O module is compatible with the IFM, see pages 40 and 41.
Cable TypeA69, B69, C69, D69, E69, F69, G69
Pre-wired cables for 8- and 16-channel Bulletin 1769 digital I/O modules
RTN18 I/O-ready cable with Cat. No. 1746-RTBN18 terminal block
RTN10 I/O-ready cable with Cat. No. 1746-RTBN10 terminal block
R71 Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1771 I/O modules ➊
Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001-020 0.1…2.0 m (0.328…6.56 ft)
0.1 m (0.328 ft increments)Build-to-Order
020-100 2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments
100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments
1492–CAB 010 A69
Digital Interface Cable
Bulletin No.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 17
Analog IFM Options and Features
Analog IFMs (AIFMs), similar to groups of terminal blocks, are available with either 15- or 25-pin D-shell connectors. The number of field-side wiring terminals varies with the type of module from three to five terminals per I/O channel. AIFMs are available as feed-through or fusible to customize the wiring system to your application.
All of the AIFMs have the following features:
UL Component Recognized (File E113724 Guide NRAQ2); UL recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2); CE Approved; Factory Mutual Listed (File J.I. 3000590) FM approved
Polarized D-shell connector (15- or 25-pin) for easy installation. Pre-wired cable has mating D-shell connector with slide-locking mechanism for secure connection.
Standard DIN #3 Rail mounting for quick installation.
Large rectangular write-on area acts as built-in group marking carrier for programmable controller rack, module group, and/or slot information.
Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.
High-density field-side wiring terminals allow more connections in less space and accommodate #22…12 AWG wire.
Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules.
Analog IFM
Publication 1492-TD008A-EN-P - March 2001
18 Digital/Analog Programmable Controller Wiring Systems
Analog IFM Options and Features, Continued
Analog Feed-Through Modules
Feed-through AIFMs have three terminals per I/O channel to wire the I/O module connections and device shield. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the cable shield. Some feed-through AIFMs also have special features (refer to page 18).The Cat. No. 1492-AIFM4-3 AIFM, when used with Cat. Nos. 1771-OFE2 and -OFE3 controllers, provides selectable current limiting resistors. Simply flip a DIP switch to add the 250 ohms series impedance into the output circuit. As a troubleshooting aid, test point loops access the circuit on either side of the series resistor and can be used to measure output circuit voltage/current. The limiting resistors are configured on a per channel basis.The Cat. No. 1492-AIFM6TC-3 AIFM for the Cat. No. 1756-IT6I controller provides on-board cold junction compensation to allow thermocouples to be connected remotely while still correcting for temperature at the termination point. The combination thermistor and isothermal bar acquires temperature data at the AIFM for the thermocouple module to adjust the input value.The Cat. No. 1492-AIFM8-3 AIFM has eight extra terminals commoned together in a power bus that can be used for Module Common connections or power supply connections. The extra terminals and internal jumpering eliminate the need for some terminal blocks for power connections and jumper accessories.Below are examples of the field-side connections available on the feed-through AIFMs.
4-Wire Transmitter Input
Output
AIFM
Pre-wired Cable
Analog Input Module
Power Supply Transmitter
Channel 1+
Channel 1-
SHIELD
1+
1-
AIFM
Pre-wired Cable
Analog Output Module
LOAD
OUT 0
ANL COMC
SH
0
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 19
Analog IFM Options and Features, Continued
Analog Fusible Modules
Fusible AIFMs are available for analog input modules. These AIFMs enable you to fuse the input device power source on the field-side. The field-side power source is distributed through individual on-board 5 x 20 mm fuse clips. The AIFMs have 24V DC blown fuse indicators to reduce the troubleshooting time needed to locate and replace a blown fuse. Standard fuse holders that reside in the AIFM are aided in the removal of the fuse with a fuse puller (fuses are not included). Isolation switch plugs or dummy fuses (refer to Accessories, page 200) are also available to isolate an input circuit after power is removed. In addition, once the circuit has been isolated and power restored, the input loop current can be measured in 2-wire transmitter applications.The fusible AIFMs have five terminals per input channel (except Cat. No. AIFM16-F-3, which has three terminals per channel) to wire the input module connections, device shield, and power connections for 2-, 3-, and 4-wire transmitters. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the cable shield. There are two separate power busses (416 terminals, depending on the AIFM) that can be used for +V and DC COM connections and/or Module Common. The extra terminals and internal connections eliminate additional terminal blocks and jumpers reducing spare parts inventory, saving panel space, and simplifying installation.All of the fusible AIFMs have on-board DIP switches to easily connect unused inputs to module common reducing wiring on the field-side. You no longer need extra jumper wires or comb-style jumpers to properly terminate unused inputs, as recommended on many Bulletin 1746, 1756, and 1771 analog input modules. Inputs are jumpered via DIP switch on a per-channel basis.The Cat. Nos. 1492-AIFM4I-F-5 and 1492-AIFM4C-F-5 AIFMs both have test point loops on either side of the fuse clips for easier access and connection of metering equipment. Metering equipment can also be attached to the fuse clips on other AIFMs for measuring input loop current.
Publication 1492-TD008A-EN-P - March 2001
20 Digital/Analog Programmable Controller Wiring Systems
Analog IFM Options and Features, Continued
Analog Fusible Modules, Continued
Below are examples of the field-side connections for 2- and 4-wire transmitters available on the fusible AIFMs.
2-Wire Transmitter
4-Wire Transmitter
The Cat. No. 1492-AIFMQS AIFM is a specialized module for use with the Cat. No. 1746-QS synchronized axis module. The module has four input channels that match the input requirement of the 1746-QS, a matching output channel provided for each input channel, and power terminals that provide fused field-side device power. Extra terminals allow convenient connection for power and shield terminal connections. An example of the field-side connections is shown below.
AIFM
Pre-wired CableAnalog Input Module
Power Supply
Transmitter
+V
V1
1+
SHIELD
1-
VCOM
Channel 1+
Channel 1-
AIFM
Pre-wired Cable
Analog Input ModulePower Supply
Transmitter
+V
V1
1+
1-
SHIELD
VCOM
Channel 1+
Channel 1-
+INT 1
-INT 1
+ RET 1
-RET 1
+OUT 1
OUT COM
+ Interrogate 1
- Interrogate 1
+ Return 1
- Return 1
Drive Output 1
Drive Common
12
24
13
25
11
23
2
3
1
11
17
26
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
Sensor
Load
+INT 1
-INT 1
+ RET 1
-RET 1
+OUT 1
OUT COM
+ Interrogate 1
- Interrogate 1
+ Return 1
- Return 1
Drive Output 1
Drive Common
12
24
13
25
11
23
2
3
1
11
17
26
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
Sensor
Load
AIFMAnalog Input Module
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 21
AIFM Cat. No. Explanation for Analog I/O Modules
Important: The following AIFM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
No. Analog I/O Channels4 4 channels: input, output,
or 2 input/output combination
4C 4 channels: 2 input/2 output combination
4I 4 input channels6S 6 isolated input or output
channels6TC 6 thermocouple input
channels8 8 input or output channels16 16 input channelsPI 8 input/2 output channels
1492–AIFM 16–F–5
Input Fuse Clips and Blown Fuse IndicatorsBlank No fuse clipsF 5 x 20 mm fuse clips with
24V DC blown fuse indicators for output modules
No. Field-Side Wiring Terminals3 3 per I/O channel5 5 per input channelAnalog Interface Modules
Bulletin No.
Publication 1492-TD008A-EN-P - March 2001
22 Digital/Analog Programmable Controller Wiring Systems
Pre-Wired Cable Cat. No. Explanation for Bulletins 1746, 1756, and 1771 Analog I/O Modules
Important: The following analog cable cat. no. breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
Pre-Wired Cable Cat. No. Explanation for Bulletin 1746 and 1769 Analog I/O Modules
Important: The following analog cable cat. no. breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
A-Cable TypeA, B, C, D,L, Q
Pre-wired cables for Bulletin 1746 analog and RTD I/O modules.
E, F, G, H, J Pre-wired cables for Bulletin 1771 analog and RTD I/O modules.
TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z
Pre-wired cables for Bulletin 1756 analog, RTD, and thermocouple I/O modules.
M Pre-wired cables for Bulletin 1757 pulse input I/O modules
Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001-020 0.1…2.0 m (0.328…6.56 ft)
0.1 m (0.328 ft increments)Build-to-Order
020-100 2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments
100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments
1492–ACABLE 050 A
Analog Interface Cables
Bulletin No.
Cable TypeA46 Pre-wired cables for Bulletin 1746-NI16I and
-NI16V analog modules. AA69, AB69, BA69, BB69, BC69, BD69
Pre-wired cables for Bulletin 1769 analog I/O modules.
Standard or Build-to-Order Length Cable005 0.5 m (1.64 ft) Standard010 1.0 m (3.28 ft)025 2.5 m (8.20 ft)050 5.0 m (16.40 ft)001-020 0.1…2.0 m (0.328…6.56 ft)
0.1 m (0.328 ft increments)Build-to-Order
020-100 2.0…10.0 m (6.56…32.8 ft)0.5 m (1.64 ft) increments
100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments
1492–ACAB 005 A46
Analog Interface Cables
Bulletin No.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 23
Ordering Digital and Analog Wiring Systems
To order the proper IFM/XIM/AIFM pre-wired cable:1. Determine I/O platform (e.g., Bulletin 1746, 1756, 1769, 1771) and the
cat. no. of the I/O module being specified. 2. Determine whether you require field-side LEDs, fusing for over-current
protection, or relays (check voltage ratings for LEDs, fuse blown indication, relay, and coil).
3. Determine your field-side wiring requirements. Are extra terminals needed?
4. Determine desired cable length (0.5 m, 1.0 m, 2.5 m, 5.0 m, or build-to-order) based on wiring needs from I/O module to IFM/XIM/AIFM.
5. Refer to selection tables as follows:
Ordering Digital IFM-Ready Cables and IFMs/XIMs
For pinout and wiring information, refer to IFM-Ready Cable Specifications on page 129 and the selection table on page 44.
Ordering Digital I/O Module-Ready Cables
To order the proper I/O module-ready cable, the following information is required:
• Type of connector needed for the I/O module(s) (cat. no. of the wiring arm or removable terminal block).
• Code for the desired cable length: 010 = 1.0 m 025 = 2.5 m 050 = 5.0 m Build-to-order length
Selection Table Quick Reference
Platform Page No.
Bulletin 1746 Digital 25
Bulletin 1746 Analog 28
Bulletin 1756 Digital 30
Bulletin 1756 Analog 33
Bulletin 1769 Digital 36
Bulletin 1769 Analog 37
Bulletin 1771 Digital 40
Bulletin 1771 Analog 43
Publication 1492-TD008A-EN-P - March 2001
24 Digital/Analog Programmable Controller Wiring Systems
Selection Tables Using Bulletin 1746 Selection Tables to Make Valid Cat. Nos.
Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are
compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.
4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CABLE➊ (for digital cables) or
1492-ACABLE➊ (for analog cables). See footnote ➊ on pages 27 and 28.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 25
Selection Tables, Continued
Bulletin 1746 SLC 500 IFMs and Cables
➊ One expander is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to attach it to the master.
Bulletin 1746 Digital 16-Point and 8-Point Isolated I/O Modules
Type of IFM
Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1746-…
IA16
IB16
IC16
IG16
IH16
IM16
IN16
ITB
16
ITV1
6
IV16
OA
16
OB
16
OB
16E
OB
P16
OG
16
OV1
6
OVP
16
OW
16
OX8
Feed-through
Standard 1492-IFM20F A B B E B A B B B B C E E E E E E D D
Narrow standard 1492-IFM20FN A B B E B — B B B B G E E E E E E N N
Extra terminals 1492-IFM20F-2 A B B E B A B B B B C E E E E E E D —
3-wire sensor type input devices 1492-IFM20F-3 A B B E B — B B B B — — — — — — — — —
LED Indicating
Standard with 24V AC/DC LEDs 1492-IFM20D24 — B — — — — B B B B — E E E — E E D —
Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — B — — — — B B B B — E E E — — — N —
Standard with 120V AC/DC LEDs 1492-IFM20D120 A — — — B — — — — — C — — — — — — D —
Narrow standard with 120V AC LEDs 1492-IFM20D120N A — — — — — — — — — G — — — — — — N —
24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — — — — — — — E E E — E E D —
24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — B — — — — B B B B — — — — — — — — —
120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — — — C — — — — — — D —
120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 A — — — — — — — — — — — — — — — — —
3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — B — — — — B B B B — — — — — — — —
Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM20DS24-4 — — — — — — — — — — — — — — — — — — S
Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — — — — — — — — — — — — — — — S
240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — — — C — — — — — — D —
240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — — — A — — — — — — — — — — — — —
Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — — — — — — C E E E — E E D —
Extra terminals with 24V AC/DC B/F indicators 1492-IFM20F-F24-2 — — — — — — — — — — — E E E — E E D —
Extra terminals with 120V AC B/F indicators 1492-IFM20F-F120-2 — — — — — — — — — — C — — — — — — D —
Extra terminals with 240V AC B/F indicators 1492-IFM20F-F240-2 — — — — — — — — — — C — — — — — — D —
Extra terminals with 24V AC/DC B/F indicators 1492-IFM20F-F24A-2 — B — — — — B B — — — — — — — E E — —
Extra terminals with 120V AC/DC B/F indicators 1492-IFM20F-F120A-2 A — — — B — — — — — — — — — — — — — —
Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — — — — — — — — — — — — — — — S
Isolated with extra terminals and 24V AC/DC blown fuse indicators
1492-IFM20F-FS24-2 — — — — — — — — — — — — — — — — — — S
Isolated with four terminals/input and 24V AC/DC blown fuse indicators
1492-IFM20F-FS24A-4 — — — — — — — — — — — — — — — — — — —
Isolated with extra terminals and 120V AC/DC blown fuse indicators
1492-IFM20F-FS120-2 — — — — — — — — — — — — — — — — — — S
Isolated with four terminals/output and 120V AC/DC blown fuse indicators
1492-IFM20F-FS120-4 — — — — — — — — — — — — — — — — — — S
Isolated with four terminals/input and 120V AC/DC blown fuse indicators
1492-IFM20F-FS120A-4 — — — — — — — — — — — — — — — — — — —
Isolated with four terminals/output and 240V AC/DC blown fuse indicators
1492-IFM20F-FS240-4 — — — — — — — — — — — — — — — — — — S
Relay Master
20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — — — — — — — E E E — — — — —
20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — — — CR — — — — — — — —
Relay Expander
Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — — ➊ ➊ ➊ — — — — —
Expander with eight (8)120V AC relays 1492-XIM120-8R — — — — — — — — — — ➊ — — — — — — — —
Fusible Expander
8-ch. expander with 24V DC B/F indicators 1492-XIMF-F24-2 — — — — — — — — — — — ➊ ➊ ➊ — — — — —
8-ch. expander with 120V AC B/F indicators 1492-XIMF-F120-2 — — — — — — — — — — ➊ — — — — — — — —
Feed-through Expander
Expander with eight feed-through channels 1492-XIMF-2 — — — — — — — — — — ➊ ➊ ➊ ➊ — — — — —
Publication 1492-TD008A-EN-P - March 2001
26 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1746 SLC 500 IFMs and Cables, Continued
➊ Two or three expanders can be connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.
Bulletin 1746 Digital 32-Point I/O Modules
Type of IFM Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1746-…
IB32
IV32
OB32
OB32
E
OV32
Feed-through Standard 1492-IFM40F H H H H HExtra terminals 1492-IFM40F-2 H H H H H3-wire sensor type input devices 1492-IFM40F-3 H H — — —
LED Indicating Standard with 24V AC/DC LEDs 1492-IFM40D24 H H H H H24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — H H H24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 H H — — —120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — — — —120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 H H — — —Isolated with 24/48V AC/DC LEDs and four terminals/output 1492-IFM40DS24-4 — — — — —Isolated with 24V AC/DC LEDs and four terminals/input 1492-IFM40DS24A-4 — — — — —Isolated with 120V AC LEDs and four terminals/output 1492-IFM40DS120-4 — — — — —Isolated with 120V AC LEDs and four terminals/input 1492-IFM40DS120A-4 — — — — —Isolated with 240V AC LEDs and four terminals/input 1492-IFM40DS240A-4 — — — — —
Fusible Extra terminals for outputs 1492-IFM40F-F-2 — — H H HExtra terminals with 24V AC/DC blown fuse indicators 1492-IFM40F-F24-2 — — H H HExtra terminals with 120V AC blown fuse indicators 1492-IFM40F-F120-2 — — — — —Isolated with extra terminals for outputs 1492-IFM40F-FS-2 — — — — —Isolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM40F-FS24-2 — — — — —Isolated with 24V AC/DC blown fuse indicators and four terminals/output
1492-IFM40F-FS24-4 — — — — —
Isolated with extra terminals and 120V AC/DC blown fuse indicators 1492-IFM40F-FS120-2 — — — — —Isolated with 120V AC/DC blown fuse indicators and four terminals/output
1492-IFM40F-FS120-4 — — — — —
Isolated with 240V AC/DC blown fuse indicators and four terminals/output
1492-IFM40F-FS240-4 — — — — —
Isolated with 24V AC/DC blown fuse indicators and four terminals/input 1492-IFM40F-FS24A-4 — — — — —Isolated with 120V AC/DC blown fuse indicators and four terminals/input
1492-IFM40F-FS120A-4 — — — — —
Relay Master 40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — H H —40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R — — H H —
Relay Expander Expander with eight (8) 24V DC relays 1492-XIM24-8R — — ➊ ➊ —
Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — —Fusible Expander 8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — ➊ ➊ —
8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — —Feed through Expander Expander with eight feed-through channels 1492-XIMF-2 — — ➊ ➊ —
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 27
Selection Tables, Continued
Bulletin 1746 SLC 500 IFMs and Cables, Continued
These pre-wired cables have a pre-wired removable terminal block (RTB) on one end to connect to the front of a Bulletin 1746 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables.
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005N is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1746-OW16 I/O module. Build-to-order lengths are also available.
The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1746 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050RTBR is for a 5.0 m cable with a pre-wired Cat. No. 1746-RT25R RTB on one end.
Note: The following I/O Modules do not have RTBs: 1746-IA4, 1746-IA8, 1746-IB8, 1746-IM4, 1746-IM8, 1746-IV8, 1746-OA8, 1746-OB8.
Pre-Wired Cables for Bulletin 1746 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1746I/O Module Cat. No.
1492-CABLE➊ A 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-IA16, -IM161492-CABLE➊ B 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-IB16, -IH16, -IN16, -ITB16, -ITV161492-CABLE➊ C 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OA161492-CABLE➊ CR 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OA161492-CABLE➊ D 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OW16, -OX81492-CABLE➊ E 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-IG16, -OB16, -OB16E, -OBP16, -OG16, -OV16, -OVP161492-CABLE➊ G 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OA161492-CABLE➊ H 0.5, 1.0, 2.5, 5.0 m Yes 40 1746-IB32, -IV32, -OB32, -OB32E, -OV321492-CABLE➊ N 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OW16, -OX81492-CABLE➊ S 0.5, 1.0, 2.5, 5.0 m Yes 20 1746-OX8
I/O Module-Ready Cables for Bulletin 1746 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1746I/O Module Cat. No.
1492-CABLE➋ N3 1.0, 2.5, 5.0 m Yes 40 1746-IB32, -IV32, -OB32, -OV32, -OB32E1492-CABLE➋ RTBB 1.0, 2.5, 5.0 m Yes 20 1746-IB16, -IC16, -IG16, -IH16, -IN16, -ITB16, -ITV16,
-IV16, -OB16, -OB16E, -OBP8, -OBP16, -OG16, -OV16, -OVP16
1492-CABLE➋ RTBO 1.0, 2.5, 5.0 m Yes 20 1746-OW16, -OX81492-CABLE➋ RTBR 1.0, 2.5, 5.0 m Yes 20 1746-IA16, -OA16, -OAP12, -IM16
Publication 1492-TD008A-EN-P - March 2001
28 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1746 SLC 500 AIFMs and Cables
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1746 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. To use this table, you must first have selected an IFM from the preceding table.
➊ To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM4I-F-5 IFM to a Cat. No. 1746-NI4 I/O module.
Bulletin 1746 Analog I/O Modules
Type of AIFM Description of AIFM AIFM Cat. No. I/O Module Cat. No. 1746-…
FIO4
I
FIO4
V
NI4
NI8
NIO
4I
NIO
4V
NO4
I
NO4
V
NR4
QS NI1
6I
NI1
6V
Feed-through 4-channel with 3 terminals/channel 1492-AIFM4-3 L L A — L L B B — — — —6-channel isolated with 3…4 terminals/channel
1492-AIFM6S-3 — — — — — — — — D — — —
8-channel with 3 terminals/channel 1492-AIFM8-3 — — C — — — — — — A46 A46Thermocouple 6-channel with 3 terminals/channel 1492-AIFM6TC-3 — — — — — — — — — — — —Fusible 2-channel with 24V blown fuse
indicators, test points, 5 terminals/input, 3 terminals/output
1492-AIFM4C-F-5 L L — — L L — — — — — —
4-channel with 24V blown fuse indicators, test points, 5 terminals/input
1492-AIFM4I-F-5 — — A — — — — — — — — —
8-channel with 24V blown fuse indicators, 5 terminals/channel
1492-AIFM8-F-5 — — — C — — — — — — — —
16-channel with 24V blown fuse indicators, 3 terminals/channel
1492-AIFM16-F-3 — — — — — — — — — — A46 A46
16-channel with 24V blown fuse indicators, 5 terminals/channel
1492-AIFM16-F-5 — — — — — — — — — — — —
4-input/4-output channel with 8 fuses and 24V blown fuse indicators
1492-AIFMQS — — — — — — — — — Q — —
Pre-Wired Cables for Bulletin 1746 Analog I/O Modules
Cable Cat. No. Standard Cable Lengths (m) Build-to-Order Available AIFM Connector Mating 1746 I/O Module Cat. No.1492-ACABLE➊ A 0.5, 1.0, 2.5, 5.0 Yes 15-pin D-shell 1746-NI41492-ACABLE➊ B 0.5, 1.0, 2.5, 5.0 Yes 15-pin D-shell 1746-NO4I, -NO4V1492-ACABLE➊ C 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-NI81492-ACABLE➊ D 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-NR41492-ACABLE➊ L 0.5, 1.0, 2.5, 5.0 Yes 15-pin D-shell 1746-NIO4I, -NIO4V, -FIOVI, -FIO4V1492-ACABLE➊ Q 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-QS1492-ACAB➊ A46 0.5, 1.0, 2.5, 5.0 Yes 25-pin D-shell 1746-NI16I, -NI16V
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 29
Selection Tables, Continued
Using Bulletin 1756 Selection Tables to Make Valid Cat. Nos.
Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are
compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.
4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CABLE➊ (for digital cables) or
1492-ACABLE➊ (for analog cables). See footnote ➊ on pages 32 and 34.
Publication 1492-TD008A-EN-P - March 2001
30 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1756 ControlLogix IFMs and Cables
➊ One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to connect it to the master.
Bulletin 1756 Digital 8-Point and 16-Point I/O Modules
Type of IFM
Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1756-…
IA8D
IA16
IB16
IC16
IN16
OA8
OA8D
OA8E
OA16
OB8
OB16
E
OC8
ON8
Feed-through
Standard 1492-IFM20F U X X X X U U U X U X U UNarrow standard 1492-IFM20FN U X X X X U U U X U X U UExtra terminals 1492-IFM20F-2 U X X X X U U U X U X U U3-wire sensor type input devices 1492-IFM20F-3 — X X X X — — — — — — — —
LED Indicating
Standard with 24V AC/DC LEDs 1492-IFM20D24 — — X — X — — — — — X — —Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — — X — X — — — — — X — —Standard with 120V AC/DC LEDs 1492-IFM20D120 U X — — — — — — — — — — —Narrow standard with 120V AC LEDs 1492-IFM20D120N U X — — — — — — X — — — —24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — — — — — — X — —24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — — X — X — — — — — — — —120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — X — — — —120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 U X — — — — — — — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — — X — X — — — — — — — —Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM20DS24-4 — — — — — — — — — W — W WIsolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — — W V V — — — — —240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — — — — — —240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — — — — — — — — — — —
Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — — — — X — X — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24-2 — — — — — — — — — — X — —Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120-2 — — — — — — — — X — — — —Extra terminals with 240V AC blown fuse indicators 1492-IFM20F-F240-2 — — — — — — — — X — — — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24A-2 — — X — X — — — — — — — —Extra terminals with 120V AC/DC blown fuse indicators 1492-IFM20F-F120A-2 — X — — — — — — — — — — —Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — — W V V — W — W WIsolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24-2 — — — — — — — — — W — W WIsolated with 4 terminals/input and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24A-4 — — — — — — — — — — — — —Isolated with extra terminals and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-2 — — — — — W V V — — — — —Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-4 — — — — — W V V — — — — —Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120A-4 U — — — — — — — — — — — —Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 1492-IFM20F-FS240-4 — — — — — W — — — — — — —
Relay Master
20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — — — — — — X — —20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — X — — — —
Relay Expander
Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — ➊ — —Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — ➊ — — — —
Fusible Expander
Expander with eight (8) 24V channels with blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — ➊ — —Expander with eight (8) 120V channels with blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — ➊ — — — —
Feed-through Expander
Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — — — ➊ — ➊ — —
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 31
Selection Tables, Continued
Bulletin 1756 ControlLogix IFMs and Cables, Continued
➊ Two or three expander modules are connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.
Bulletin 1756 Digital 16-Point Isolated and 32-Point I/O Modules
Type of IFM
Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1756-…
IA16
I
IB16
D
IB16
I
IB32
IH16
I
IM16
I
OA16
I
OB8E
I
OB16
D
OB16
I
OB32
OH8I
OW16
I
OX8I
Feed-through
Standard 1492-IFM40F Y Y Y Z Y — Y Y Y Y Z Y Y Y
Extra terminals 1492-IFM40F-2 — Y — Z — — — — Y — Z — — —
3-wire sensor type input devices 1492-IFM40F-3 — — — Z — — — — — — — — — —
LED Indicating
Standard with 24V AC/DC LEDs 1492-IFM40D24 — — — Z — — — — — — Z — — —
24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — — — — — — — — — Z — — —
24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 — — — Z — — — — — — — — — —
120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — — — — — — — — — — — — —
120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 — — — — — — — — — — — — — —
3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 — — — Z — — — — — — — — — —
Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM40DS24-4 — — — — — — — Y Y Y — — Y Y
Isolated with 24V AC/DC LEDs and 4 terminals/input 1492-IFM40DS24A-4 — Y Y — — — — — — — — — — —
Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM40DS120-4 — — — — — — Y — — — — — Y Y
Isolated with 120V AC LEDs and 4 terminals/input 1492-IFM40DS120A-4 Y — — — — — — — — — — — — —
Isolated with 240V AC LEDs and 4 terminals/input 1492-IFM40DS240A-4 — — — — — Y — — — — — — — —
Fusible Extra terminals for outputs 1492-IFM40F-F-2 — — — — — — — — — — Z — — —
Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM40F-F24-2 — — — — — — — — — — Z — — —
Extra terminals with 120V AC blown fuse indicators 1492-IFM40F-F120-2 — — — — — — — — — — — — — —
Isolated with extra terminals for outputs 1492-IFM40F-FS-2 — — — — — — Y Y Y Y — Y Y Y
Isolated with extra terminals and 24V AC/DC blown fuse indicators
1492-IFM40F-FS24-2 — — — — — — — Y Y Y — — Y Y
Isolated with 24V AC/DC blown fuse indicators and 4 terminals/output
1492-IFM40F-FS24-4 — — — — — — — Y Y Y — — Y Y
Isolated with extra terminals and 120V blown fuse indicators 1492-IFM40F-FS120-2 — — — — — — Y — — — — Y Y Y
Isolated with 120V AC/DC blown fuse indicators and 4 terminals/output
1492-IFM40F-FS120-4 — — — — — — Y — — — — — Y Y
Isolated with 240V AC/DC blown fuse indicators and 4 terminals/output
1492-IFM40F-FS240-4 — — — — — — Y — — — — — Y Y
Isolated with 24V AC/DC blown fuse indicators and 4 terminals/input
1492-IFM40F-FS24A-4 — Y Y — — — — — — — — — — —
Isolated with 120V AC/DC blown fuse indicators and 4 terminals/input
1492-IFM40F-FS120A-4 Y — — — Y — — — — — — — — —
Relay Master
40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — — — — — — — — — Z — — —
40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R — — — — — — — — — — Z — — —
Relay Expander
Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — ➊ — — —
Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — — — — — — —
Fusible Expander
8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — ➊ — — —
8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — — — — — — —
Feed-through Expander
Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — — — — — ➊ — — —
Publication 1492-TD008A-EN-P - March 2001
32 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1756 ControlLogix IFMs and Cables, Continued
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables.
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM40F IFM to a Cat. No. 1756-IA16I I/O module.
The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1756 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050TBNH is for a 5.0 m cable with a pre-wired Cat. No. 1756-TBNH RTB on one end.
Pre-Wired Cables for Bulletin 1756 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1756I/O Module Cat. No.
1492-CABLE➊ U 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-IA8D, -OA8, -OA8D, -OA8E, -OB8, -OC8, -ON8
1492-CABLE➊ V 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-OA8D, -OA8E
1492-CABLE➊ W 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-OA8, -OBE, -OC8, -ON8
1492-CABLE➊ X 0.5, 1.0, 2.5, 5.0 m Yes 20 1756-IA16, -IB16, -IC16, -IN16, -OA16, -OB16E
1492-CABLE➊ Y 0.5, 1.0, 2.5, 5.0 m Yes 40 1756-IA16I, -IB16D, -IB16I, -IH16, -OA16I, -OB8EI, -OB16D, -OB16I, -OH8I, -OW16I, -OX8I
1492-CABLE➊ Z 0.5, 1.0, 2.5, 5.0 m Yes 40 1756-IB32, -OB32
I/O Module-Ready Cables for Bulletin 1756 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1756I/O Module Cat. No.
1492-CABLE➋ TBNH 1.0, 2.5, 5.0 m Yes 20 1756-IA8D, -IA16, -IB16, -IC16, -IN16, -OA8, -OA8D, -OA8E, -OA16, -OB8, -OB16E, -OC8, -ON8
1492-CABLE➋ TBCH 1.0, 2.5, 5.0 m Yes 40 1756-IA16I, -IB16D, -IB16I, -IB32, -IF16, -IH16I, -IM16I, -OA16I, -OB8EI, -OB16D, -OB16I, -OB32, -OH8I, -OW16I, -OX8I
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 33
Selection Tables, Continued
Bulletin 1756 ControlLogix AIFMs and Cables
➊ Some analog I/O modules can be operated in up to four modes (current/voltage, single-ended/differential) based on connections. In all cases, each channel is factory-configured for the same mode. However, you can field configure any channel for another mode.
Bulletin 1756 Analog I/O Module ➊
Type of AIFM Description of AIFM
AIFM Cat. No. I/O Module
Cat. No.1756-…
Cat. No.1757-…
IF6I
(Cur
rent
)
IF6I
(Vol
tage
)
IF8
(Sgl
-End
Vol
t)
IF8
(Sgl
-End
Crt)
IF8
(Diff
Vol
tage
)
IF8
(Diff
Cur
rent
)
IF16
(Sgl
-End
Vol
t)
IF16
(Sgl
-End
Crt
)
IF16
(Diff
Vol
tage
)
IF16
(Diff
cur
rent
)
IR6I
IT6I
OF4
(Vol
tage
)
OF4
(Cur
rent
)
OF6C
I
OF6V
I
OF8
(Vol
tage
)
OF8
(Cur
rent
)
PIM
Feed-through 4-channel with 3 terminals/channel
1492-AIFM4-3 — — — — — — — — — — — — VA VB — — — — —
6-channel isolated with 3…4 terminals/channel
1492-AIFM6S-3 X Y — — — — — — — — Z — — — Y Y — —
8-channel with 3 terminals/channel
1492-AIFM8-3 — — TA TB TC TD UA UB UC UD — — — — — — WA WB —
Thermocouple 6-channel with 3 terminals/channel
1492-AIFM6TC-3 — — — — — — — — — — — Y — — — — — — —
Fusible 8-channel with 5 terminals/channel
1492-AIFM8-F-5 — — TA TB TC TD — — UC UD — — — — — — — — —
16-channel with 3 terminals/channel
1492-AIFM16-F-3 — — — — — — UA UB UC UD — — — — — — — — —
16-channel with 5 terminals/channel
1492-AIFM16-F-5 — — — — — — UA UB UC UD — — — — — — — — —
8 input/2 output channels
1492-AIFMPI — — — — — — — — — — — — — — — — — — M
Publication 1492-TD008A-EN-P - March 2001
34 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1756 ControlLogix AIFMs and Cables, Continued
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 analog I/O module and a D-shell connector on the other end to plug into a 20- or 40-terminal AIFM. You must first select the AIFM from the preceding selection table.
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM6TC-3 analog IFM to a Cat. No. 1756-IT6I I/O module.
Pre-Wired Cables for 1756 Analog I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
AIFMConnector
Mating 1756I/O Module Cat. No.
1492-ACABLE➊ M 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1757-PIM
1492-ACABLE➊ X 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Current
1492-ACABLE➊ Y 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Voltage, -IT6I, -OF6CI, -OF6VI
1492-ACABLE➊ Z 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IR16
1492-ACABLE➊ TA 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Single-Ended Voltage
1492-ACABLE➊ TB 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Single-Ended Current
1492-ACABLE➊ TC 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Differential Voltage
1492-ACABLE➊ TD 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF8 Differential Current
1492-ACABLE➊ UA 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Single-Ended Voltage
1492-ACABLE➊ UB 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Single-Ended Current
1492-ACABLE➊ UC 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Differential Voltage
1492-ACABLE➊ UD 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-IF16 Differential Current
1492-ACABLE➊ VA 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1756-OF4 Voltage
1492-ACABLE➊ VB 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1756-OF4 Current
1492-ACABLE➊ WA 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-OF8 Voltage
1492-ACABLE➊ WB 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1756-OF8 Current
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 35
Selection Tables, Continued
Using Bulletin 1769 Selection Tables to Make Valid Cat. Nos.
Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are
compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.
4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CAB➊ (for digital cables) or
1492-ACAB➊ (for analog cables). See footnote ➊ on pages 37 and 38.
Publication 1492-TD008A-EN-P - March 2001
36 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables
➊ Sink mode only.➋ One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included
with each expander to connect it to the master.
Bulletin 1769 Digital I/O Modules
Type of IFM Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1769-…
IA8I
IA16
IQ16
IM12
OA8
OB16
OV16
OW8
OW8I
Feed-through Standard 1492-IFM20F F69 A69 B69 G69 C69 E69 E69 C69 D69Narrow standard 1492-IFM20FN F69 A69 B69 — C69 E69 E69 C69 —Extra terminals 1492-IFM20F-2 — A69 B69 G69 C69 E69 E69 C69 —3-wire sensor type input devices 1492-IFM20F-3 — A69 B69 — — — — — —
LED Indicating
Standard with 24V AC/DC LEDs 1492-IFM20D24 — — B69 — — E69 E69 — —Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — — B69 — — E69 — — —Standard with 120V AC/DC LEDs 1492-IFM20D120 — A69 — — — — — — —Narrow standard with 120V AC LEDs 1492-IFM20D120N — A69 — — — — — — —24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — E69 E69 — —24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — — B69 — — — — — —120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — —120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 — A69 — — — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — — B69 — — — — — —Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM20DS24-4 — — — — — — — C69 D69Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — C69 — — C69 D69240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — —240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — G69 — — — — —
Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — E69 E69 — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24-2 — — — — — E69 E69 — —Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120-2 — — — — — — — — —Extra terminals with 240V AC blown fuse indicators 1492-IFM20F-F240-2 — — — — — — — — —Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24A-2 — — B69 ➊ — — — E69 — —Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120A-2 — A69 — — — — — — —Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — C69 — C69 D69Isolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24-2 — — — — — — — C69 D69Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators 1492-IFM20F-FS24A-4 — — — — — — — — —Isolated with extra terminals and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-2 — — — — C69 — — C69 D69Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120-4 — — — — C69 — — C69 D69Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators 1492-IFM20F-FS120A-4 — — — — — — — — —Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 1492-IFM20F-FS240-4 — — — — — — — — D69
Relay Master
20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — E69 — — —20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — —
Relay Expander
Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — ➋ — — —Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — —
Fusible Expander
8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — ➋ — — —8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — —
Feed-through Expander
Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — ➋ — — —
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 37
Selection Tables, Continued
Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables, Continued
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 digital I/O module and a connector on the other end to plug into a 20-terminal IFM/XIM. You must first select the IFM/XIM from the preceding selection table.
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CAB005E69 is for a 0.5 m cable that can be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1769-OB16 I/O module.
The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1769 I/O module and 20 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CAB050RTN10 is for a 5.0 m cable with a wired Cat. No. 1746-RTBN10 on one end.
Pre-Wired Cables for Bulletin 1769 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1746I/O Module Cat. No.
1492-CAB➊ A69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IA161492-CAB➊ B69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IQ161492-CAB➊ C69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OA8, -OW81492-CAB➊ D69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OW8I1492-CAB➊ E69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OB16, -OV161492-CAB➊ F69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IA8I1492-CAB➊ G69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IM12
I/O Module-Ready Cables for Bulletin 1769 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1746I/O Module Cat. No.
1492-CAB➋ RTN10 1.0, 2.5, 5.0 m Yes 10 1769-OA8, -OW81492-CAB➋ RTN18 1.0, 2.5, 5.0 m Yes 18 1769-IA8I, -IA16, -IQ16, -OB16, -OV16, -OW8I, -IM12
Publication 1492-TD008A-EN-P - March 2001
38 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 AIFMs and Cables
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 analog I/O module and a connector on the other end to plug into a 20-terminal AIFM. You must first select the AIFM from the preceding selection table.
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACAB005➋ is for a 0.5 m cable.
IFMs for Bulletin 1769 Analog I/O Modules
AIFM Cat. No. I/O Module Cat. No. 1769-… OF2
(Voltage) OF2
(Current)IF4
(Single-Ended Voltage)
IF4(Single-Ended
Current)
IF4(Differential
Voltage)
IF4(Differential
Current)1492-AIFM4-3 AA69 AB69 BA69 BB69 BC69 BD691492-AIFM6S-3 — — — — — —1492-AIFM6TC-3 — — — — — —1492-AIFM8-3 — — — — — —1492-AIFM4I-F-5 — — — — — —1492-AIFM4C-F-5 — — — — — —1492-AIFM8-F-5 — — — — — —1492-AIFM16-F-3 — — — — — —1492-AIFM16-F-5 — — — — — —1492-AIFMQS — — — — — —
Pre-Wired Cables for Bulletin 1769 Analog I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
AIFMConnector
Mating 1769I/O Module Cat. No.
1492-ACAB➊ AA69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-OF2 Voltage1492-ACAB➊ AB69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-OF2 Current1492-ACAB➊ BA69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Single-Ended Voltage1492-ACAB➊ BB69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Single-Ended Current1492-ACAB➊ BC69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Differential Voltage1492-ACAB➊ BD69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Differential Current
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 39
Selection Tables, Continued
Using Bulletin 1771 Selection Tables to Make Valid Cat. Nos.
Follow these steps when using the selection tables to make valid cat. nos.:1. Find the appropriate table based on the cat. no. of the I/O module.2. Find the column for the I/O module.3. Follow the column down to determine which IFMs/XIMs/AIFMs are
compatible with the I/O module as indicated by letter code. If there is no letter code, the IFM/XIM/AIFM is not compatible with the I/O module.
4. Select the desired IFM/XIM/AIFM.5. Configure the cable cat. no. using 1492-CABLE➊ (for digital cables) or
1492-ACABLE➊ (for analog cables). See footnote ➊ on pages 42 and 43.
Publication 1492-TD008A-EN-P - March 2001
40 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1771 PLC-5 IFMs and Cables
➊ Either F or FF.➋ One expander is connected to a master to provide a total of 16 outputs. An extender cable is included with each
expander to connect it to the master.
IFMs for Bulletin 1771 Digital 8-Point and 16-Point I/O Modules
Type of IFM
Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1771-…
IA IA2
IAD
IB IBD
ICD
IGD
IH IN IND
IT OA
D
OB
D
OG
D
OM
D
ON
D
IMD
Feed-through
Standard 1492-IFM20F — — F — F F F — — F — ➊ ➊ F F ➊ F
Narrow standard 1492-IFM20FN — — F — F F F — — F — ➊ ➊ F — ➊ —
Extra terminals 1492-IFM20F-2 — — F — F F F — — F — ➊ ➊ F F ➊ F
3-wire sensor type input devices 1492-IFM20F-3 — — F — F F F — — F — — — — — — —
LED Indicating
Standard with 24V AC/DC LEDs 1492-IFM20D24 — — — — F F — — — F — ➊ ➊ — — ➊ —
Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N — — — — F F — — — F — ➊ ➊ — — ➊ —
Standard with 120V AC/DC LEDs 1492-IFM20D120 — — F — — — — — — — — — — — — — —
Narrow standard with 120V AC LEDs 1492-IFM20D120N — — F — — — — — — — — ➊ — — — — —
24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 — — — — — — — — — — — ➊ ➊ — — ➊ —
24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 — — — — F F — — — F — — — — — — —
120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 — — — — — — — — — — — ➊ — — — — —
120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 — — F — — — — — — — — — — — — — —
3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 — — — — F F — — — — — — — — — — —
Isolated with 24/48V AC/DC LEDs and 4 terminals/output
1492-IFM20DS24-4 — — — — — — — — — — — — — — — — —
Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM20DS120-4 — — — — — — — — — — — — — — — — —
240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 — — — — — — — — — — — — — — F — —
240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 — — — — — — — — — — — — — — — — F
Fusible Extra terminals for outputs 1492-IFM20F-F-2 — — — — — — — — — — — F F — — F —
Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24-2 — — — — — — — — — — — F F — — F —
Extra terminals with 120V AC blown fuse indicators 1492-IFM20F-F120-2 — — — — — — — — — — — F — — — — —
Extra terminals with 240V AC blown fuse indicators 1492-IFM20F-F240-2 — — — — — — — — — — — — — — F — —
Extra terminals with 24V AC/DC blown fuse indicators 1492-IFM20F-F24A-2 — — — — F F — — — F — — — — — — —
Extra terminals with 120V AC/DC blown fuse indicators 1492-IFM20F-F120A-2 — — F — — — — — — — — — — — — — —
Isolated with extra terminals for outputs 1492-IFM20F-FS-2 — — — — — — — — — — — — — — — — —
Isolated with extra terminals and 24V AC/DC blown fuse indicators
1492-IFM20F-FS24-2 — — — — — — — — — — — — — — — — —
Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators
1492-IFM20F-FS24A-4 — — — T — — — T T — T — — — — — —
Isolated with extra terminals and 120V AC/DC blown fuse indicators
1492-IFM20F-FS120-2 — — — — — — — — — — — — — — — — —
Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators
1492-IFM20F-FS120-4 — — — — — — — — — — — — — — — — —
Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators
1492-IFM20F-FS120A-4 T T — — — — — — — — — — — — — — —
Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators
1492-IFM20F-FS240-4 — — — — — — — — — — — — — — — — —
Relay Master
20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R — — — — — — — — — — — — ➊ — — — —
20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R — — — — — — — — — — — ➊ — — — — —
Relay Expander
Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — — — — — — — ➋ — — — —
Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — — — — ➋ — — — — —
Fusible Expander
8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — — — ➋ — — — —
8-channel expander with 120V AC blown fuse indicators
1492-XIMF-F120-2 — — — — — — — — — — — ➋ — — — — —
Feed-through Expander
Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — — — — — — ➋ ➋ — — — —
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 41
Selection Tables, Continued
Bulletin 1771 PLC-5 IFMs and Cables, Continued
➊ Two or three expanders are connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.
➋ Cable Cat. No. 1492-CAB➊ R71 has only the N.O. contacts connected.
IFMs for Bulletin 1771 Digital 16-Point Isolated and 32-Point I/O Modules
Type of IFM Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1771-…
IAN
IBN
ID16
IQ16
IVN
OAN
OBN
OD16
ODD
OQ16
OVN
OW16
OWN
OWNA
Feed-through
Standard 1492-IFM40F J J M M K L L M M M L R L LExtra terminals 1492-IFM40F-2 J J — — K L L — — — L R L L3-wire sensor type input devices 1492-IFM40F-3 — J — — K — — — — — — — — —
LED Indicating
Standard with 24V AC/DC LEDs 1492-IFM40D24 — J — — K — L — — — L — L L24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — — — — — L — — — L — L L24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 — J — — K — — — — — — — — —120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — — — — L — — — — — — L L120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 J — — — — — — — — — — — — —3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 — J — — K — — — — — — — — —Isolated with 24/48V AC/DC LEDs and 4 terminals/output 1492-IFM40DS24-4 — — — — — — — — — M — — — —Isolated with 24V AC/DC LEDs and 4 terminals/input 1492-IFM40DS24A-4 — — — M — — — — — — — — — —Isolated with 120V AC LEDs and 4 terminals/output 1492-IFM40DS120-4 — — — — — — — M M — — — — —Isolated with 120V AC LEDs and 4 terminals/input 1492-IFM40DS120A-4 — — M — — — — — — — — — — —Isolated with 240V AC LEDs and 4 terminals/input 1492-IFM40DS240A-4 — — — — — — — — — — — — — —
Fusible Extra terminals for outputs 1492-IFM40F-F-2 — — — — — L L — — — L — L LExtra terminals with 24V AC/DC blown fuse indicators 1492-IFM40F-F24-2 — — — — — — L — — — L — L LExtra terminals with 120V AC blown fuse indicators 1492-IFM40F-F120-2 — — — — — L — — — — — — L LIsolated with extra terminals for outputs 1492-IFM40F-FS-2 — — — — — — — M M M — R71 ➋ — —Isolated with extra terminals and 24V AC/DC blown fuse indicators
1492-IFM40F-FS24-2 — — — — — — — — — M — R71 ➋ — —
Isolated with 24V AC/DC blown fuse indicators and 4 terminals/output
1492-IFM40F-FS24-4 — — — — — — — — — M — — — —
Isolated with extra terminals and 120V blown fuse indicators 1492-IFM40F-FS120-2 — — — — — — — M M — — R71 ➋ — —Isolated with 120V AC/DC blown fuse indicators and 4 terminals/output
1492-IFM40F-FS120-4 — — — — — — — M M — — — — —
Isolated with 240V AC/DC blown fuse indicators and 4 terminals/output
1492-IFM40F-FS240-4 — — — — — — — — — — — — — —
Isolated with 24V AC/DC blown fuse indicators and 4 terminals/input
1492-IFM40F-FS24A-4 — — — M — — — — — — — — — —
Isolated with 120V AC/DC blown fuse indicators and 4 terminals/input
1492-IFM40F-FS120A-4 — — M — — — — — — — — — — —
Relay Master
40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — — — — — L — — — — — — —40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R — — — — — — L — — — — — — —
Relay Expander
Expander with eight (8) 24V DC relays 1492-XIM24-8R — — — — — — ➊ — — — — — — —Expander with eight (8) 120V AC relays 1492-XIM120-8R — — — — — — — — — — — — — —
Fusible Expander
8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — ➊ — — — — — — —8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — — — — — — — — — — — — —
Feed through Expander
Expander with eight (8) feed-through channels 1492-XIMF-2 — — — — — — ➊ — — — — — — —
Publication 1492-TD008A-EN-P - March 2001
42 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
Bulletin 1771 PLC-5 IFMs and Cables, Continued
These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005M is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM40F IFM to a Cat. No. 1771-ODD I/O module.
➋ Cable Cat. No. 1492-CAB➊ R71 has only the N.O. contacts connected.
The I/O module-ready cables have a wiring arm on one end to plug onto the front of a Bulletin 1771 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
➌ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050WN is for a 5.0 m cable with a pre-wired Cat. No. 1771-WN wiring arm on one end.
➍ Includes an optional 3A fuse in the Wiring Arm for 1771 PLC mating I/O Modules.
Pre-Wired Cables for Bulletin 1771 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1771I/O Modules Cat. No.
1492-CABLE➊ F 0.5, 1.0, 2.5, 5.0 m Yes 20 1771-IAD, -IBD, -ICD, -IGD, -IND, -OAD, -OBD, -OGD, -OMD, -OND, -IMD
1492-CABLE➊ FF 0.5, 1.0, 2.5, 5.0 m Yes 20 1771-OAD, -OBD, -OND1492-CABLE➊ J 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-IAN, -IBN1492-CABLE➊ K 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-IVN1492-CABLE➊ L 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-OAN, -OBN, -OVN, -OWN, -OWNA1492-CABLE➊ M 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-ID16, -IQ16, -OD16, -ODD, -OQ161492-CABLE➊ R 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-OW161492-CAB➊ R71➋ 0.5, 1.0, 2.5, 5.0 m Yes 40 1771-OW161492-CABLE➊ T 0.5, 1.0, 2.5, 5.0 m Yes 20 1771-IA, -IA2, -IB, -IH, -IN, -IT
I/O Module-Ready Cables for 1771 Digital I/O Modules
CableCat. No.
Standard Cable Lengths
Build-to-Order Available
No. of Conductors
Mating 1771I/O Modules Cat. No.
1492-CABLE➌ WA 1.0, 2.5, 5.0 m Yes 12 1771-IA, -IA2, -IB, -IC, -IH, -IM, -IN, -IT, -IV, -OA, -OB, -OC, -OM, -ON, -OP
1492-CABLE➌ WD 1.0, 2.5, 5.0 m Yes 12 1771-ID, -ID01, -OD, -ODZ, -OR, -OW, -OYL, -OZL1492-CABLE➌ WH 1.0, 2.5, 5.0 m Yes 20 1771-IAD, -IBD, -ICD, -IGD, -IMD, -IND, -OAD, -OBD, -OGD,
-OMD, -OND1492-CABLE➌ WHF 1.0, 2.5, 5.0 m Yes 20 1771-IBD ➍ , -OAD ➍ , -OBD ➍ , -OMD ➍ , -OND ➍
1492-CABLE➌ WN 1.0, 2.5, 5.0 m Yes 40 1771-IAN, -IBN, -ID16, -IQ16, -IV16, -OAN, -OBN, -OD16, -ODD, -OQ16, -OVN, -OW16, -OWN, -OWNA
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 43
Selection Tables, Continued
Bulletin 1771 PLC-5 AIFMs and Cables
These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. You must first select the IFM from the preceding selection table.
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005E is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM8-3 IFM to a Cat. No. 1771-IFE I/O module. Build-to-order lengths are also available.
IFMs for Bulletin 1771 Analog I/O Modules
Type of AIFM Description of AIFM AIFM Cat. No. I/O Module Cat. No. 1771-…
IFE
(Diff
eren
tial)
IFE
(Sin
gle-
Ende
d
IL IR OFE
1
OFE
2
OFE
3
Feed-through 4-channel with 3 terminals/channel 1492-AIFM4-3 — — — — G G G6-channel isolated with 3…4 terminals/channel 1492-AIFM6S-3 — — — J — — —8-channel with 3 terminals/channel 1492-AIFM8-3 E F H — — — —
Thermocouple 6-channel with 3 terminals/channel 1492-AIFM6TC-3 — — — — — — —Fusible 8-channel with 5 terminals/channel 1492-AIFM8-F-5 E — — — — — —
16-channel with 3 terminals/channel 1492-AIFM16-F-3 — F — — — — —16-channel with 5 terminals/channel 1492-AIFM16-F-5 — F — — — — —
Pre-Wired Cables for Bulletin 1771 Analog I/O Modules
Cable Cat. No. Standard Cable Lengths Build-to-Order Available AIFM Connector Mating 1771 I/O Modules1492-ACABLE➊ E 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IFE Differential1492-ACABLE➊ F 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IFE Single-Ended1492-ACABLE➊ G 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1771-OFE1, -OFE2, -OFE31492-ACABLE➊ H 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IL1492-ACABLE➊ J 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1771-IR
Publication 1492-TD008A-EN-P - March 2001
44 Digital/Analog Programmable Controller Wiring Systems
Selection Tables, Continued
IFM-Ready I/O Cables
IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (CABLE➊ P and CABLE➊ Q, respectively). These cables allow the IFM to be used in specialty applications that require a custom connection.
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.
Build-to-Order Length Cables
All Bulletin 1492 cables are available in build-to-order lengths. Consult your local Allen-Bradley Sales Office or distributor for availability.
IFM-Ready I/O Cable
CableCat. No.
Standard Cable Lengths
Insulation Rating
No. Conductors
Conductor Size
Nominal Outer Diameter
Current/Conductor
Compatible IFM Cat. Nos.
1492-CABLE➊ P 1.0, 2.5, 5.0 m 300V, 80°C 20 22 AWG 9 mm (0.36 in.) 2 A 1492-IFM20…, 1492-XIM20…
1492-CABLE➊ Q 1.0, 2.5, 5.0 m 300V, 80°C 40 22 AWG 11.7 mm (0.46 in.) 2 A 1492-IFM40…, 1492-XIM40…
Build-to-Order Length Cables
Cable Lengths Increment Size Cable Length Codes Example Cat. No.
0.1…2.0 m 0.1 m 001…020 1492-CABLE015A (1.5 m cable)
2.0…10.0 m 0.5 m 020…100 1492-CABLE075P (7.5 m cable)
10.0…99.0 m 1.0 m 100…990 1492-CABLE150RTBB (15.0 m cable)
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 45
Digital/Analog Programmab le Controller Wiring SystemsDigital IFM Specifications
For all IFM dimensions, refer to page 152.For all XIM dimensions, refer to page 158.For general Adhesive Label Card information, refer to page 162.For Field-Side Wiring Diagrams, refer to the Wiring System web page at http://www.ab.com/catalogs/b113. Refer to page 202 for specific platform web site information. Refer to the online documentation for new product information.
Symbols and Terminal Identification Conventions Used Throughout the Pinout Section
IFMCat. No.
Page No. for Specifications,
Application Notes, and Pinout
Page No. for
Adhesive Label Card
IFMCat. No.
Page No. for Specifications,
Application Notes, and Pinout
Page No. for
Adhesive Label Card
IFMCat. No.
Page No. for Specifications,
Application Notes, and Pinout
Page No. for
Adhesive Label Card
1492-IFM20F 46 163 1492-IFM20F-F240-2 68 169 1492-IFM40F-F-2 90 1721492-IFM20FN 47 174 1492-IFM20F-FS-2 69 177 1492-IFM40F-F24-2 91 1721492-IFM20F-2 48 166 1492-IFM20F-FS24-2 70 177 1492-IFM40F-F120-2 92 1721492-IFM20F-3 49 171 1492-IFM20F-FS24A-4 71 178 1492-IFM40F-FS-2 93 1831492-IFM20D24 50 163 1492-IFM20F-FS120-2 72 177 1492-IFM40F-FS24-2 94 1831492-IFM20D24N 51 174 1492-IFM20F-FS120-4 73 169 1492-IFM40F-FS24-4 95 1841492-IFM20D120 52 163 1492-IFM20F-FS120A-4 74 178 1492-IFM40F-FS120-2 96 1831492-IFM20D120N 53 174 1492-IFM20F-FS240-4 75 169 1492-IFM40F-FS120-4 97 1851492-IFM20D24-2 54 166 1492-IFM40F 76 165 1492-IFM40F-FS240-4 98 1841492-IFM20D24A-2 55 170 1492-IFM40F-2 77 172 1492-IFM40F-FS24A-4 99 1851492-IFM20D120-2 56 166 1492-IFM40F-3 78 179 1492-IFM40F-FS120A-4 100 1851492-IFM20D120A-2 57 170 1492-IFM40D24 79 165 1492-XIM4024-16R 101 1891492-IFM20D240-2 58 166 1492-IFM40D24-2 80 172 1492-XIM4024-8R 103 1861492-IFM20D240A-2 59 170 1492-IFM40D24A-2 81 172 1492-XIM2024-8R 105 1861492-IFM20D24-3 60 179 1492-IFM40D120-2 82 172 1492-XIM20120-8R 106 1861492-IFM20DS24-4 61 176 1492-IFM40D120A-2 83 172 1492-XIM24-8R 107 1871492-IFM20DS120-4 62 176 1492-IFM40D24-3 84 179 1492-XIM120-8R 109 1871492-IFM20F-F-2 63 166 1492-IFM40DS24-4 85 182 1492-XIMF-F24-2 111 1881492-IFM20F-F24-2 64 166 1492-IFM40DS24A-4 86 182 1492-XIMF-F120-2 113 1881492-IFM20F-F24A-2 65 181 1492-IFM40DS120-4 87 182 1492-XIMF-2 115 1881492-IFM20F-F120-2 66 166 1492-IFM40DS120A-4 88 182 — — —1492-IFM20F-F120A-2 67 181 1492-IFM40DS240A-4 89 182 — — —
~~
Fuse and Blown Fuse Indicator (where applicable)
LED Circuit
LED Indicator
Connector Pin
Field-Side Terminal
N.C./N.O. Relay Contact
Relay Coil Circuit
46 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring Systems
1492-IFM20F
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 152.
Pinout
1492-IFM20F Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…264V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
—
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
2
3
18
19
20
A1
A2
A3
A18
A19
A20
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 47
1492-IFM20FN
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 152.
Pinout
1492-IFM20FN Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
—
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B9
2
11
18
B1020
A2
A9
3
10
A11
A1019
Publication 1492-TD008A-EN-P - March 2001
48 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus is isolated into two groups of 10 terminals. This allows each group of the I/O devices to reference a different power source.
4. Dimensions Refer to page 153.
Pinout1492-IFM20F-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…264V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
2
3
18
19
20
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 49
1492-IFM20F-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 171. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power busses are connected to one common (one bus has 17 terminals, and one bus has 18 terminals). All of the input devices used must reference the same power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20F-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
17 (bottom row). 18 (middle row)
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
C1
C16
B1
B2
B17
B18
A1
A2
A16
A17
A18
3
18
1
20
Publication 1492-TD008A-EN-P - March 2001
50 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20D24
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring The LEDs are powered from the two-position terminal block. Make only one connection to the power source for normal operation. Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 152.
Pinout
1492-IFM20D24 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
2
3
18
19
20
A1
A2
A3
A18
A19
A20
L1 (+)
L2 (-)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 51
1492-IFM20D24N
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 152.
Pinout
1492-IFM20D24N Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B9
2
11
18
B1020
A2
A9
3
10
A11
A1019
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
52 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20D120
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. This IFM is not recommended for use with input devices or programmable controller output circuits having an off-state leakage current exceeding 0.5 mA. Use Cat. No. 1492-IFM20D120N instead, or use Cat. No. 1492-IFM20D120A-2 for input modules and Cat. No. 1492-IFM20D120-2 for output modules. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The LEDs are isolated into two groups of eight terminals. This allows each group of the I/O devices to reference a different power source.
4. Dimensions Refer to page 152.
Pinout
1492-IFM20D120 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
A1
A2
A3
A10
A11
A18
A19
A20
L2 (-)
L2 (-)
1
2
3
10
11
18
19
20
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 53
1492-IFM20D120N
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 152.
Pinout
1492-IFM20D120N Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B9
2
11
18
B1020
A2
A9
3
10
A11
A1019
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
54 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20D24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20D24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG(0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in.(0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B10
B11
B18
B19
B20
1
2
3
10
11
18
19
20
A1
A2
A9
A10
A11
A12
A19
A20
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 55
1492-IFM20D24A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20D24A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
20
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B20
1
2
3
18
20
A1
A2
A19
A20
B1919
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
56 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20D120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20D120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B10
B11
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
1
2
3
10
11
18
19
20
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 57
1492-IFM20D120A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20D120A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
20
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B20
A1
A2
A19
A20
B19
1
2
3
18
20
19
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
58 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20D240-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus comprises 10 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20D240-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B10
B11
B18
B19
B20
1
2
3
10
11
18
19
20
A1
A2
A9
A10
A11
A12
A19
A20LED Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 59
1492-IFM20D240A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 153.
Pinout
1492-IFM20D240A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
20
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B20
1
2
3
18
20
A1
A2
A19
A20
B1919
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
60 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20D24-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.
2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The LEDs are connected to one common. All of the input devices used must reference the same power source.
4. Dimensions Refer to page 153.
Pinout1492-IFM20D24-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
18
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
C1
C16
B1
B2
B17
B18
A1
A2
A17
A18
3
18
2
1
19
20
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 61
Digital/Analog Programmab le Controller Wiring Systems
1492-IFM20DS24-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.
2. Wiring Refer to the Label Section on page 176. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are eight individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 153.
Pinout1492-IFM20DS24-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…60V AC/DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
4.1 mA
No. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B2
B3
B6
A1
B1
B7
B10
B11
B14
B15
B18
B19
B20
A2
A3
A4
A9
A10
A11
A12
A17
A18
A19
A20
(even)
(even)
(odd)
(odd)
10
2
8
12
18
3
9
11
17
20
1
19
Publication 1492-TD008A-EN-P - March 2001
62 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20DS120-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 176. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are eight individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 153.
Pinout1492-IFM20DS120-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.6 mA
No. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
10
2
8
B2
B3
B6
A1
B1
12 B7
18 B10
3 B11
9 B14
11 B15
17 B18
20 B19
B20
1
A2
A3
A4
A9
A10
A11
A12
A17
A18
A19
A20
(even)
(even)
(odd)
(odd)
19
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 63
1492-IFM20F-F-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus and fuse clips are isolated into two groups of 10 terminals (eight fuse clips). This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 153.
Pinout1492-IFM20F-F-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
1
2
3
18
19
20
Publication 1492-TD008A-EN-P - March 2001
64 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-F24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 153.
Pinout
1492-IFM20F-F24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
1
2
3
18
19
20
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 65
1492-IFM20F-F24A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input or output devices to reference a different power source.
5. Dimensions Refer to page 153.
Pinout
1492-IFM20F-F24A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
2
18
19
20
B1
B2
B3
B18
B19
B20
A1
A2
A3
A10
A20
A19
A18
A11
3
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
66 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-F120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 153.
Pinout
1492-IFM20F-F120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
1
2
3
18
19
20
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 67
1492-IFM20F-F120A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input devices to reference a different power source.
5. Dimensions Refer to page 153.
Pinout
1492-IFM20F-F120A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
1.2 mA
No. of Terminals per Device Common
—
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
2
3
18
19
20
B1
B2
B3
B18
B19
B20
A1
A2
A3
A10
A20
A19
A18
A11
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
68 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-F240-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Sixteen fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input devices to reference a different power source.
5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-F240-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
1.2 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
2
3
18
19
20
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 69
1492-IFM20F-FS-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips are isolated into eight groups of terminals. This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-FS-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
10
3
5
15
17
20
B1
B2
B3
B8
B9
B10
1
2
A1
A2
4 A3
6 A4
8 A5
12 A6
14 A7
16 A8
18 A9
19 A10
(odd)
Publication 1492-TD008A-EN-P - March 2001
70 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-FS24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-FS24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
—
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
(odd)
10
3
5
15
17
20
B1
B2
B3
B8
B9
B10
1
2
A1
A2
4 A3
6 A4
8 A5
12 A6
14 A7
16 A8
18 A9
19 A10
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 71
1492-IFM20F-FS24A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 178. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into two groups of terminals. This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-FS24A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
—
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
3
4
5
16
17
18
B6
B7
B8
B11
B12
B13
2 B14
19 A14
A7
A9
A6
A8
A11
A13
A12
A10
6
15
B9
B10
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
72 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-FS120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source.
5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-FS120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
(odd)
10
3
5
15
17
20
B1
B2
B3
B8
B9
B10
1
2
A1
A2
4 A3
6 A4
8 A5
12 A6
14 A7
16 A8
18 A9
19 A10
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 73
1492-IFM20F-FS120-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source.
5. Dimensions Refer to page 153.
Pinout
1492-IFM20F-FS120-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2.5 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
2
3
A11
B11A3
B3
4
1
5
A12
B12A4
B4
6
7
A13
B13A5
B5
8
9
A14
B14
A6
B6
12
11
19
A15
B15
A7
B7
14
13
A16
B16A8
B8
16
15
A17
B17A9
B9
18
17
A18
B18
A10
B10
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
74 Digital/Analog Programmable Controller Wiring Systems
1492-IFM20F-FS120A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 178. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into two groups of terminals. This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-FS120A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V AC/DC
Maximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 A
Maximum Current (per Module) 12 A
Indicator Circuit Current (Nominal) 2.5 mA
No. of Terminals per Device Common —
Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)
Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12
No. of Wires 3 3 3 2 1 1
3
4
5
16
17
18
B6
B7
B8
B11
B12
B13
2 B14
19 A14
A7
A9
A6
A8
A11
A13
A12
A10
6
15
B9
B10
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 75
Digital/Analog Programmab le Controller Wiring Systems
1492-IFM20F-FS240-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source.
5. Dimensions Refer to page 153.
Pinout
1492-IFM20F-FS240-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2.5 mANo. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
2
3
A11
B11A3
B3
4
1
5
A12
B12A4
B4
6
7
A13
B13A5
B5
8
9
A14
B14
A6
B6
12
11
19
A15
B15
A7
B7
14
13
A16
B16A8
B8
16
15
A17
B17A9
B9
18
17
A18
B18
A10
B10
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
76 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 165. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 154.
Pinout
1492-IFM40F Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
—
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
A1
A2
A3
A18
A20
B1
B2
B3
1
3
5
35
39
2
4
6
(odd)
(even)
A1937
B18
B20
36
40
B1938
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 77
1492-IFM40F-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus is isolated into four groups of 10 terminals. This allows each group of the I/O devices to reference a different power source.
4. Dimensions Refer to page 155.
Pinout1492-IFM40F-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B20
B21
B22
B23
1
3
5
35
39
2
4
6
(odd)
(even)
B1937
B38
B40
36
40
B3938
A1
A2
A9
A10
A11
A12
A19
A20
A21
A22
A29
A30
A31
A32
A39
A40
Publication 1492-TD008A-EN-P - March 2001
78 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power busses are isolated into two groups of 18 terminals. This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block.
4. Dimensions Refer to page 155.
Pinout1492-IFM40F-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…60V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
18
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
TB2
TB1
5
35
C1
C16
B1B2
B17B18
A1A2
A17A18
6
36
C1
C16
B1B2
B17B18
A1A2
A17A18
TB1
TB2
(odd)
(even)
3
1
37
39
4
2
38
40
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 79
1492-IFM40D24
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring The LEDs are powered off the two-position terminal block. Make only one connection to the power source for normal operation. Refer to the Label Section on page 165. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source.
4. Dimensions Refer to page 154.
Pinout
1492-IFM40D24 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
1
3
5
35
37
39
A1
A2
A3
A18
A19
A20
L1 (+)
L2 (-)
(odd)
(even)
2
4
6
B1
B2
B3
36
38
40
B18
B19
B20
Publication 1492-TD008A-EN-P - March 2001
80 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40D24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.
4. Dimensions Refer to page 155.
Pinout
1492-IFM40D24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B21B22B23
B30
B31
B38B39B40
246
20
22
363840
A21
A22
A29
A30
A31
A32
A39
A40
(even)
(even)
B1B2B3
B10
B11
B18B19B20
135
19
21
353739
A1
A2
A9
A10
A11
A12
A19
A20
(odd)
(odd)
LEDCircuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 81
1492-IFM40D24A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of input devices to reference a different power source.
4. Dimensions Refer to page 155.
Pinout
1492-IFM40D24A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DC
Maximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 A
Maximum Current (per Module) 12 A
Indicator Circuit Current (Nominal) 2 mA
No. of Terminals per Device Common 10
Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 m2)
Wire Strip Length 0.32 in. (8 mm)
Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12
No. of Wires 3 3 3 2 1 1
B23
B30
B31
B38
B40
6
20
22
36
40
A31
A32
A39
A40
B3938
A21
A22
A29
A30
B212
B224
(even)
(even)
B3
B10
B11
B18
B20
5
19
21
35
39
A11
A12
A19
A20
B1937
A1
A2
A9
A10
B11
B23
(odd)
(odd)
LEDCircuit
Publication 1492-TD008A-EN-P - March 2001
82 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40D120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source.
4. Dimensions Refer to page 155.
Pinout
1492-IFM40D120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B21B22B23
B30
B31
B38B39B40
246
20
22
363840
A21
A22
A29
A30
A31
A32
A39
A40
(even)
(even)
B1B2B3
B10
B11
B18B19B20
135
19
21
353739
A1
A2
A9
A10
A11
A12
A19
A20
(odd)
(odd)
LEDCircuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 83
1492-IFM40D120A-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of input devices to reference a different power source.
4. Dimensions Refer to page 155.
Pinout1492-IFM40D120A-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B23
B30
B31
B38
B40
6
20
22
36
40
A31
A32
A39
A40
B3938
A21
A22
A29
A30
B212
B224
(even)
(even)
B3
B10
B11
B18
B20
5
19
21
35
39
A11
A12
A19
A20
B1937
A1
A2
A9
A10
B11
B23
(odd)
(odd)
LEDCircuit
Publication 1492-TD008A-EN-P - March 2001
84 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40D24-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation The power busses and LEDs are isolated into two groups of 18 terminals (16 LEDs). This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block.
4. Dimensions Refer to page 155.
Pinout
1492-IFM40D24-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common 18Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
TB2
TB1
5
35
C1
C16
B1B2
3
B17B18
A1A2
A17A18
1
37
39
6
36
C1
C16
B1B2
B17B18
A1A2
A17A18
TB1
TB2
4
2
38
40
(odd)
(even)
LED Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 85
1492-IFM40DS24-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 156.
Pinout
1492-IFM40DS24-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…60V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 4.1 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
5
19
B1
B8
21 B25
35 B32
6 B9
20 B16
22 B17
36 B24
A1
A2
A15
A16
A17
A18
A31
A32
(even)
(odd)
(odd)
(even)
Publication 1492-TD008A-EN-P - March 2001
86 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40DS24A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 156.
Pinout
1492-IFM40DS24A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 4.1 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B9
B16
B1
B8
B17
B24
A1
A2
A31
A32
(odd)
(even)
B25
B32
(even)
(odd)
6
20
5
19
22
36
21
35
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 87
Digital/Analog Programmab le Controller Wiring Systems
1492-IFM40DS120-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 156.
Pinout
1492-IFM40DS120-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 2.6 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
5
19
B1
B8
21 B25
35 B32
6 B9
20 B16
22 B17
36 B24
A1
A2
A15
A16
A17
A18
A31
A32
(even)
(odd)
(odd)
(even)
Publication 1492-TD008A-EN-P - March 2001
88 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40DS120A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 156.
Pinout
1492-IFM40DS120A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V ACMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 2.6 mANo. of Terminals per Device Common 2Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
6
20
B9
B16
5 B1
19 B8
22 B17
36 B24
A1
A2
A31
A32
(odd)
(even)
21 B25
35 B32
(even)
(odd)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 89
1492-IFM40DS240A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Isolation There are 16 individually isolated channels. LED returns are individually isolated.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Dimensions Refer to page 156.
Pinout
1492-IFM40DS240A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 204…264V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current 2.6 mANo. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B17
B32
6
36
(even)
A17
A32
5
35
(odd)
A1
B1
A16
B16
Publication 1492-TD008A-EN-P - March 2001
90 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-F-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus and fuse clips are isolated into four groups of 10 terminals (eight fuse clips). This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 157.
Pinout1492-IFM40F-F-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
B21
B22
B23
B38
B39
B40
(odd)
(even)
A21
A22
A29
A30
A31
A32
A39
A40
1
3
5
35
37
39
2
4
6
36
38
40
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 91
1492-IFM40F-F24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 157.
Pinout
1492-IFM40F-F24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
B21
B22
B23
B38
B39
B40
(odd)
(even)
A21
A22
A29
A30
A31
A32
A39
A40
1
3
5
35
37
39
2
4
6
36
38
40
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
92 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-F120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source.
5. Dimensions Refer to page 157.
Pinout
1492-IFM40F-F120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• CSA Certified (File LR1234 Class 321107)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
10
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B1
B2
B3
B18
B19
B20
A1
A2
A9
A10
A11
A12
A19
A20
B21
B22
B23
B38
B39
B40
(odd)
(even)
A21
A22
A29
A30
A31
A32
A39
A40
1
3
5
35
37
39
2
4
6
36
38
40
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 93
1492-IFM40F-FS-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
5. Dimensions Refer to page 158.
Pinout1492-IFM40F-FS-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B3
B18
(even)
A3
A18
(odd)
6
36
5
35
Publication 1492-TD008A-EN-P - March 2001
94 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-FS24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
5. Dimensions Refer to page 158.
Pinout
1492-IFM40F-FS24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
36
B3
B18
(even)
A3
A18
(odd)
6
5
35
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 95
1492-IFM40F-FS24-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 184. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
6. Dimensions Refer to page 157.
Pinout1492-IFM40F-FS24-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DC
Maximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 A
Maximum Current (per Module) 12 A
Indicator Circuit Current (Nominal) 2 mA
No. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)
Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12
No. of Wires 3 3 3 2 1 1
5
6
A18
B18
A2
B2
7
8
A19
B19
A3
B3
33
34
A32
B32
A16
B16
35
36
A33
B33
A17
B17
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
96 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-FS120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
5. Dimensions Refer to page 158.
Pinout
1492-IFM40F-FS120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2.5 mA
No. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B3
B18
(even)
A3
A18
(odd)
6
36
5
35
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 97
1492-IFM40F-FS120-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
6. Dimensions Refer to page 157.
Pinout
1492-IFM40F-FS120-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current 1.4 mANo. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
A2
B2
A4
B4
A30
B30
A32
B32
(odd)
(even)
A3
B3
A5
B5
A31
B31
A33
B33
5
6
7
8
33
34
35
36
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
98 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-FS240-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
2. Wiring Refer to the Label Section on page 184. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
6. Dimensions Refer to page 157.
Pinout1492-IFM40F-FS240-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 204…264V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current 1.4 mANo. of Terminals per Device Common
2
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
5
6
A18
B18
A2
B2
7
8
A19
B19
A3
B3
33
34
A32
B32
A16
B16
35
36
A33
B33
A17
B17
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 99
Digital/Analog Programmab le Controller Wiring Systems
1492-IFM40F-FS24A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
6. Dimensions Refer to page 157.
Pinout
1492-IFM40F-FS24A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current 3.1 mANo. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
5
6
7
8
A3
B3
A5
B5
33
34
A31
B31
35
36
A33
B33
(odd)
(even)
A2
B2
A4
B4
A30
B30
A32
B32
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
100 Digital/Analog Programmable Controller Wiring Systems
1492-IFM40F-FS120A-4
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections.
5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source.
6. Dimensions Refer to page 157.
Pinout1492-IFM40F-FS120A-4 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current 1.4 mANo. of Terminals per Device Common
1
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
A3
B3
A5
B5
A31
B31
A33
B33
(odd)
(even)
A2
B2
A4
B4
A30
B30
A32
B32
5
6
7
8
33
34
35
36
Blown Fuse Indicator Circuit
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 101
1492-XIM4024-16R
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 189. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 158.
Pinout
Refer to page 102.
1492-XIM4024-16R Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
10 A12 A per adjacent pair
Maximum Current (per Module)
48 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common
16
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
102 Digital/Analog Programmable Controller Wiring Systems
1492-XIM4024-16R, Continued
Pinout, Continued
206
248
2810
3012
3214
3116
3418
3320
1222
1124
1426
1328
1630
1532
1834
1736
CJOUTCN
5
7
9
A3
K0
K1
K2
K3
K4
K5
K6
K7
A4
A5
B3
B4
B5
A6
A7
A8
11
B6
B7
B8
13
B9
B10
B11
15
B12
B13
B14
17
A9
A10
A11
19
A12
A13
A14
CN TB1~~
~~
~~
~~
~~
~~
~~
~~
8
21
23
25
A3
A4
A5
B3
B4
B5
A6
A7
A8
27
B6
B7
B8
29
B9
B10
B11
31
B12
B13
B14
33
A9
A10
A11
35
A12
A13
A14
5
9
7
8
10A2
B1
A1
B2
3
4
1
2
6A2
B1
A1
B2
40
37
38
39
4
1
2
3
CJOUT
CN TB2~~
~~
~~
~~
~~
~~
~~
~~
K8
K9
K10
K11
K12
K13
K14
K15
TB2
TB1
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 103
1492-XIM4024-8R
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 158.
Pinout
Refer to page 104.
1492-XIM4024-8R Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
10 A12 A per adjacent pair
Maximum Current (per Module)
48 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common
8
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
104 Digital/Analog Programmable Controller Wiring Systems
1492-XIM4024-8R, Continued
Pinout, Continued
5
7
9
A3
K0
K1
K2
K3
K4
K5
K6
K7
A4
A5
B3
B4
B5
A6
A7
A8
11
B6
B7
B8
13
B9
B10
B11
15
B12
B13
B14
17
A9
A10
A11
19
A12
A13
A14
5
9
7
8
10A16
B15
A15
B16
3
4
1
2
6A2
B1
A1
B2
40
37
38
39
4
1
2
3
CJOUT
CN TB~~
~~
~~
~~
~~
~~
~~
~~
2021
2423
2825
3027
3229
3131
3433
3335
126
118
1410
1312
1614
1516
1818
1720
2222
2624
1926
2128
2330
2532
2734
2936
CJOUTCN
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 105
1492-XIM2024-8R
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 159.
Pinout
1492-XIM2024-8R Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 10 A12 A per adjacent pair
Maximum Current (per Module)
48 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
CJOUT
2011
2412
2813
3014
3215
3116
3417
3318
CN
3
4
5
A3
A4
A5
B3
B4
B5
A6
A7
A8
6
B6
B7
B8
7
B9
B10
B11
8
B12
B13
B14
9
A9
A10
A11
10
K0
K1
K2
K3
K4
K5
K6
K7
A12
A13
A14
B16
B15
B2
B1
1
2
7
8
20
19
2
1
CN TB~~
~~
~~
~~
~~
~~
~~
~~
CJOUT
CJOUT
Publication 1492-TD008A-EN-P - March 2001
106 Digital/Analog Programmable Controller Wiring Systems
1492-XIM20120-8R
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Dimensions Refer to page 159.
Pinout
1492-XIM20120-8R Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 96…132V ACMaximum Peak Voltage ➊ 600VpMaximum Current (per Output Contact)
10 A12 A per adjacent pair
Maximum Current (per Module) 48 AIndicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
CJOUT
2011
2412
2813
3014
3215
3116
3417
3318
CN
3
4
5
A3
A4
A5
B3
B4
B5
A6
A7
A8
6
B6
B7
B8
7
B9
B10
B11
8
B12
B13
B14
9
A9
A10
A11
10
K0
K1
K2
K3
K4
K5
K6
K7
A12
A13
A14
B16
B15
B2
B1
1
2
7
8
20
19
2
1
CN TB~~
~~
~~
~~
~~
~~
~~
~~
CJOUT
CJOUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 107
1492-XIM24-8R
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 187. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. This relay expander must be used with a 24V DC relay master.
4. Dimensions Refer to page 159.
Pinout
Refer to page 108.
1492-XIM24-8R Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 20…26V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
10 A12 A per adjacent pair
Maximum Current (per Module)
48 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common
8
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
108 Digital/Analog Programmable Controller Wiring Systems
1492-XIM24-8R, Continued
Pinout, Continued
16
12
8
A1
A2
A3
B1
B2
B3
A4
A5
A6
6
B4
B5
B6
4
B7
B8
B9
3
B10
B11
B12
2
A7
A8
A9
1
A10
A11
A12
27
28
~~
~~
~~
~~
~~
~~
~~
~~
CJIN TB
K0
K1
K2
K3
K4
K5
K6
K7
130
2
31 3
324
25
6
26 8
29
5
7
9
10
2024
2423
2822
3021
3220
3119
3418
3317
1415
1214
1313
1611
1110
159
187
175
CJIN CJOUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 109
1492-XIM120-8R
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 187. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. This relay expander must be used with a 120V AC relay master.
4. Dimensions Refer to page 159.
Pinout
Refer to page 110.1492-XIM120-8R Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 96…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 10 A12 A per adjacent pair
Maximum Current (per Module)
48 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
110 Digital/Analog Programmable Controller Wiring Systems
1492-XIM120-8R, Continued
Pinout, Continued
16
12
8
A1
A2
A3
B1
B2
B3
A4
A5
A6
6
B4
B5
B6
4
B7
B8
B9
3
B10
B11
B12
2
A7
A8
A9
1
A10
A11
A12
27
28
~~
~~
~~
~~
~~
~~
~~
~~
CJIN TB
K0
K1
K2
K3
K4
K5
K6
K7
130
2
31 3
324
25
6
26 8
29
5
7
9
10
2024
2423
2822
3021
3220
3119
3418
3317
1415
1214
1313
1611
1110
159
187
175
CJIN CJOUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 111
1492-XIMF-F24-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the XIM and CABLE pinouts.
4. Dimensions Refer to page 159.
Pinout
Refer to page 112.
1492-XIMF-F24-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
4 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
112 Digital/Analog Programmable Controller Wiring Systems
1492-XIMF-F24-2, Continued
Pinout, Continued
16
12
8
B1
B2
B3
B7
B8
A1
A2
B4
B5
B6
6
A3
A4
A5
4
A6
A7
A8
3
2
1
27
28
CJIN
F8
F9
F10
F11
F12
F13
F14
F15
TB
130
2
31 3
324
25
6
26 8
29
5
7
9
10
2024
2423
2822
3021
3220
3119
3418
3317
1415
1214
1313
1611
1110
159
187
175
CJIN CJOUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 113
1492-XIMF-F120-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the XIM and CABLE pinouts.
4. Dimensions Refer to page 159.
Pinout
Refer to page 114.
1492-XIMF-F120-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 85…132V ACMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
4 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common 8Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
114 Digital/Analog Programmable Controller Wiring Systems
1492-XIMF-F120-2, Continued
Pinout, Continued
16
12
8
B1
B2
B3
B7
B8
A1
A2
B4
B5
B6
6
A3
A4
A5
4
A6
A7
A8
3
2
1
27
28
CJIN
F8
F9
F10
F11
F12
F13
F14
F15
TB
130
2
31 3
324
25
6
26 8
29
5
7
9
10
2024
2423
2822
3021
3220
3119
3418
3317
1415
1214
1313
1611
1110
159
187
175
CJIN CJOUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 115
Digital/Analog Programmab le Controller Wiring Systems
1492-XIMF-2
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the XIM and CABLE pinouts.
4. Dimensions Refer to page 159.
Pinout
Refer to page 116.
1492-XIMF-2 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
4 A
Indicator Circuit Current 2.0 mANo. of Indicators per Common —Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
116 Digital/Analog Programmable Controller Wiring Systems
1492-XIMF-2, Continued
Pinout, Continued
16
12
8
B1
B2
B3
B7
B8
A1
A2
B4
B5
B6
6
A3
A4
A5
4
A6
A7
A8
3
2
1
27
28
CJIN TB
130
2
31 3
324
25
6
26 8
29
5
7
9
10
2024
2423
2822
3021
3220
3119
3418
3317
1415
1214
1313
1611
1110
159
187
175
CJIN CJOUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 117
Digital Cable Specifications
Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Digital pre-wired cables, when used with an IFM or XIM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The digital ready-to-wire cables provide one end of the cable pre-terminated, for either an IFM (IFM-ready cable) or a programmable controller I/O module (I/O module-ready cable).
Pre-Wired Cables
Specifications
The pre-wired cables have a Bulletin 1746 Removable Terminal Block, 1756 Removable Terminal Block, 1769 Removable Terminal Block, or 1771 Wiring Arm on one end and a cable connector on the other to connect to the IFM or XIM. The broad offering of digital pre-wired cables supports over 90 different 16- and 32-point Bulletin 1746, 1756, 1769, and 1771 digital I/O modules.
Publication 1492-TD008A-EN-P - March 2001
118 Digital/Analog Programmable Controller Wiring Systems
Digital Cable Specifications, Continued
Pre-Wired Cables, Continued
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005A is for a 0.5 m cable for the 1746-IA16 I/O Module. Also refer to Build-to-Order Length Cables on page 44.
Digital Pre-Wired Cable Specifications
Cat.No.
Standard Cable Lengths
Insulation Rating
No. of Conductors
Conductor Size
Nominal Outer Diameter
I/O ModuleConnector Cat. No.
1492-CABLE➊ A 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block
1492-CABLE➊ B 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25B Blue Removable Terminal Block
1492-CABLE➊ C 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block
1492-CABLE➊ CR 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block
1492-CABLE➊ D 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25C Orange Removable Terminal Block
1492-CABLE➊ E 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25B Blue Removable Terminal Block
1492-CABLE➊ F 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1771-WH (16-Point/21 Terminal) Wiring Arm
1492-CABLE➊ FF 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm
1492-CABLE➊ G 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25R Red Removable Terminal Block
1492-CABLE➊ H 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1746-N3 40-Pin Cable Connector
1492-CABLE➊ J 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm
1492-CABLE➊ K 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm
1492-CABLE➊ L 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm
1492-CABLE➊ M 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm
1492-CABLE➊ N 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25C Orange Removable Terminal Block
1492-CABLE➊ R 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm
1492-CAB➊ R71 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1771-WN (32-Point/40 Terminal) Wiring Arm
1492-CABLE➊ S 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1746-RT25C Orange Removable Terminal Block
1492-CABLE➊ T 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 11.7 mm (0.46") 1771-WA (8-Point/10 Terminal) Wiring Arm
1492-CABLE➊ U 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block
1492-CABLE➊ V 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block
1492-CABLE➊ W 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block
1492-CABLE➊ X 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1756-TBNH Removable Terminal Block
1492-CABLE➊ Y 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1756-TBCH Removable Terminal Block
1492-CABLE➊ Z 0.5, 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 1756-TBCH Removable Terminal Block
1492-CAB➊ A69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block
1492-CAB➊ B69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block
1492-CAB➊ C69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN10 Removable Terminal Block
1492-CAB➊ D69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block
1492-CAB➊ E69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block
1492-CAB➊ F69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block
1492-CAB➊ G69 0.5, 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 1769-RTBN18 Removable Terminal Block
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 119
Digital/Analog Programmab le Controller Wiring SystemsDigital Cable Specifications, Continued
Pinouts
Digital Pre-Wired Cables
The following diagrams illustrate how the individual conductors in the digital pre-wired cables are terminated at both ends. The description listed first is the wire color of the conductor connected to the removable terminal block (Bulletin 1746, 1756, and 1769 I/O) or wiring arm (1771 I/O). The number that follows in parentheses is the corresponding pin number of the IFM/XIM mating connector.
No Connection
Twisted Pair Jumper Wire
Individual Conductor
Base Color Stripe Color
Blue (24)
Black (23)
White/Green (22)
White/Red (19)
NC 20 or 40 Connector Pin Number
I/O Pin Connector Definition
1
2
39
40
1
2
19
20
20-Conductor Cable 40-Conductor Cable
IFM Mating Connector Definition
120 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsDigital Cable Specifications, Continued
Pinouts, Continued
➊ Refer to footnote on page 125.
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
Red/Green (20)Blue/Red (19)
Black (1)White (2) Orange RTB
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
Red/Green (20)Blue/Red (19)
Red RTBRed (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
Red/Green (20)Blue/Red (19)
Blue RTB
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
Red/Green (20)Blue/Red (19)
Black (1)White (2) Red RTB
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18) Red/Green (20)Blue/Red (19)
Black (1)White (2) Blue RTB
ABCD00
01
02
03
04
05
06
07
10
11
12
13
14
15
16
17
E
White (2)Black (1)
Blue/Red (19)
Red (3)Green (4)
Orange (5)Blue (6)
White/Black (7)Red/Black (8)
Green/Black (9)Orange/Black (10)
Blue/Black (11)Black/White (12)
Red/White (13)Green/White (14)
Blue/White (15)Black/Red (16)White/Red (17)
Orange/Red (18)Red/Green (20)
ABCD00
01
02
03
04
05
06
07
10
11
12
13
14
15
16
17
E
White (2)Black (1)
Blue/Red (19)
Red (3)Green (4)Orange (5)Blue (6)White/Black (7)Red/Black (8)Green/Black (9)Orange/Black (10)Blue/Black (11)Black/White (12)Red/White (13)Green/White (14)Blue/White (15)Black/Red (16)White/Red (17)Orange/Red (18)Red/Green (20)
CAUTIONDISCONNECT
POWERBEFORE
SERVICING
ALL FUSES30-250V
FUSES
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
Black (1)
White (2)
Red/White (13)
Red RTB
Blue/Red (19)
Jumper
1492-CABLE➊ F 1492-CABLE➊ FF
1492-CABLE➊ D 1492-CABLE➊ E
1492-CABLE➊ G
1492-CABLE➊ C
1492-CABLE➊ A 1492-CABLE➊ B
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 121
Digital Cable Specifications, Continued
Pinouts, Continued
➊ Refer to footnote on page 125.
1 2
39
White (2)Black (1)
Blue/Red (19)
Red (3)Green (4)Orange (5)Blue (6)White/Black (7)Red/Black (8)Green/Black (9)Orange/Black (10)Blue/Black (11)Black/White (12)Red/White (13)Green/White (14)Blue/White (15)Black/Red (16)White/Red (17)Orange/Red (18)
Red/Green (20)
40
Orange/Black-Green (32)
White/Black-Red (23)
Blue/Black-White (27)
Green/Black-Orange (31)
White/Red-Orange (35)
White/Black-Green (39)
Red/Black-White (24)
Black/Red-Green (28)
Orange/White-Blue (36)
Red/White-Green (40)
Orange/Green (21)
Green/Black-White (25)
White/Red-Green (29)
Blue/White-Orange (33)
White/Red-Blue (37)
Black/White-Red (22)
Orange/Black-White (26)
Red/Black-Green (30)
Black/White-Orange (34)
Black/White-Green (38)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
White (2)
Black (1)Blue/Red (19)
Red (3)
Green (4)
Orange (5)
Blue (6)
White/Black (7)Green/Black (9)
Orange/Black-Green (32)
Blue/Black (11)
Black/White (12)
Red/White (13)
Green/White (14)
Blue/White (15)
Black/Red (16)
White/Red (17)
Orange/Red (18)Red/Green (20)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
White/Black-Red (23)Blue/Black-White (27)
Green/Black-Orange (31)White/Red-Orange (35)White/Black-Green (39)
Red/Black (8)
Red/Black-White (24)Black/Red-Green (28)
Orange/White-Blue (36)Red/White-Green (40)
Orange/Green (21)Green/Black-White (25)White/Red-Green (29)Blue/White-Orange (33)White/Red-Blue (37)
Orange/Black (10)
Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)Black/White-Green (38)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
White (2)
Black (1)
Blue/Red (19)
Red (3)
Green (4)
Orange (5)
Blue (6)
White/Black (7)Green/Black (9)
Orange/Black-Green (32)
Blue/Black (11)
Black/White (12)
Red/White (13)
Green/White (14)
Blue/White (15)
Black/Red (16)
White/Red (17)
Orange/Red (18)Red/Green (20)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
White/Black-Red (23)Blue/Black-White (27)
Green/Black-Orange (31)White/Red-Orange (35)
White/Black-Green (39)
Red/Black (8)
Red/Black-White (24)Black/Red-Green (28)
Orange/White-Blue (36)
Red/White-Green (40)
Orange/Green (21)Green/Black-White (25)White/Red-Green (29)Blue/White-Orange (33)
White/Red-Blue (37)
Orange/Black (10)
Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)
Black/White-Green (38)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
White (2)
Black (1)
Blue/Red (19)Red (3)
Green (4)
White/Black (7)
Orange/Black-Green (32)
Blue/Black (11)
Black/White (12)
Blue/White (15)
Black/Red (16)Red/Green (20)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
White/Black-Red (23)Blue/Black-White (27)Green/Black-Orange (31)White/Red-Orange (35)White/Black-Green (39)
Red/Black (8)
Red/Black-White (24)Black/Red-Green (28)
Orange/White-Blue (36)Red/White-Green (40)
Orange (5)
Blue (6)
Green/Black (9)Red/White (13)
Green/White (14)
White/Red (17)
Orange/Red (18)
Orange/Green (21)Green/Black-White (25)
White/Red-Green (29)Blue/White-Orange (33)
White/Red-Blue (37)
Orange/Black (10)
Black/White-Red (22)Orange/Black-White (26)
Red/Black-Green (30)Black/White-Orange (34)
Black/White-Green (38)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
NC
White/Black (7)
Orange/Black-Green (32)
Red/Green (20)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
Red/Black (8)
Red/Black-White (24)
Black/Red-Green (28)
Orange/White-Blue (36)
Orange (5) Blue (6)
Red/White (13) Green/White (14)
White/Red (17)
Orange/Green (21)
Green/Black-White (25)
White/Red-Green (29)
Blue/White-Orange (33)
NC
NC
Blue/Red (19)
NC
NC
Green/Black (9)Blue/Black (11) Black/White (12)
NC
Blue/White (15) Black/Red (16)Orange/Red (18)
White/Black-Red (23)
Blue/Black-White (27)
Green/Black-Orange (31)
White/Red-Orange (35)
NC
Orange/Black (10)
Black/White-Red (22)
Orange/Black-White (26)
Red/Black-Green (30)
Black/White-Orange (34)
NC
1492-CABLE➊ H
1492-CABLE➊ J 1492-CABLE➊ K
1492-CABLE➊ M
1492-CABLE➊ L
Publication 1492-TD008A-EN-P - March 2001
122 Digital/Analog Programmable Controller Wiring Systems
Digital Cable Specifications, Continued
Pinouts, Continued
➊ Refer to footnote on page 125.
1
19
2
20
Orange (5)
Black/White (12)
White/Red (17)
Red/Green (20)
Red/Black (8)
Blue/Red (19)
Red (3)
Green/White (14)
Blue/White (15)
Black (1)
White (2)
Blue (6)
Orange/Red (18)
Green (4)
Black/Red (16)
White/Black (7)
Blue/Black (11)
Green/Black (9)
Red/White (13)
Orange/Black (10)
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
NC
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
White (2)
NC
Orange RTB
1
19
2
20
Orange (5)
Black/White (12)
White/Red (17)
NC
Red/Black (8)
NC
Blue/Red (19)
Red (3)
Green/White (14)
Blue/White (15)
Black (1)
White (2)
Blue (6)
Orange/Red (18)
Green (4)
Black/Red (16)
White/Black (7)
Blue/Black (11)
Green/Black (9)
Red/White (13)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
White (2)
Black (1)
Blue/Red (19)
Red (3)
Green (4)
Orange (5)
Blue (6)
White/Black (7)Green/Black (9)
Orange/Black-Green (32)
Blue/Black (11)
Black/White (12)
Red/White (13)
Green/White (14)
Blue/White (15)
Black/Red (16)
White/Red (17)
Orange/Red (18)Red/Green (20)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
White/Black-Red (23)Blue/Black-White (27)
Green/Black-Orange (31)White/Red-Orange (35)White/Black-Green (39)
Red/Black (8)
Red/Black-White (24)Black/Red-Green (28)
Orange/White-Blue (36)Red/White-Green (40)
Orange/Green (21)Green/Black-White (25)White/Red-Green (29)Blue/White-Orange (33)White/Red-Blue (37)
Orange/Black (10)
Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)Black/White-Green (38)
1
19
2
20
White (2)
Orange (5)
Blue (6)
White/Black (7)
Blue/Black (11)
Black/White (12)
White/Red (17)
Orange/Red (18)
Red/Green (20)
Red/Black (8)
Black (1)
Blue/Red (19)
Red (3)
Green (4)
Green/Black (9)
Red/White (13)
Green/White (14)
Blue/White (15)
Black/Red (16)
Orange/Black (10)
Red (3)
Orange (5)
White/Black (7)
Green/Black (9)
Blue/Black (11)
Red/White (13)
Blue/White (15)
White/Red (17)
Green (4)
Blue (6)
Red/Black (8)
Orange/Black (10)
Black/White (12)
Green/White (14)
Black/Red (16)
Orange/Red (18)
Blue/Red (19)
Black (1)White (2)
Orange RTB
Jumper
1492-CABLE➊ U
1492-CABLE➊ R 1492-CABLE➊ V
1492-CABLE➊ S 1492-CABLE➊ W
White (2)Blue/Red (19) A
Red (3)Green (4)Orange (5)Blue (6)Blue/White (15)Black/Red (16)White/Red (17)Orange/Red (18)White/Black (7)Blue/Black (11)
0
1
2
3
4
5
6
7
B
1492-CABLE➊ T1492-CABLE➊ N
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 123
Digital Cable Specifications, Continued
Pinouts, Continued
➊ Refer to footnote on page 125.
2
36
Blue/Red (19)
Orange (5)
Blue (6)
White/Black (7)Green/Black (9)
Orange/Black-Green (32)
Blue/Black (11)
Black/White (12)
Red/White (13)
Green/White (14)
Blue/White (15)
Black/Red (16)
White (2)
Orange/Red (18)Red/Green (20)
1
35
White/Black-Red (23)Blue/Black-White (27)
Green/Black-Orange (31)White/Red-Orange (35)
Red/Black (8)
Red/Black-White (24)Black/Red-Green (28)
Orange/White-Blue (36)
Orange/Green (21)Green/Black-White (25)
Black (1)Blue/White-Orange (33)
Orange/Black (10)
Black/White-Red (22)Orange/Black-White (26)Red/Black-Green (30)Black/White-Orange (34)
White/Red (17)
White/Red-Green (29)
White/Black-Green (39)
Red/White-Green (40)
2
36
Blue/Red (19)
Orange (5) Blue (6)White/Black (7)Green/Black (9)
Orange/Black-Green (32)
Blue/Black (11) Black/White (12)Red/White (13) Green/White (14)Blue/White (15) Black/Red (16)White/Red (17) Orange/Red (18)
Red/Green (20)
1
35
White/Black-Red (23)
Blue/Black-White (27)
Green/Black-Orange (31)
White/Red-Orange (35)
NC
Red/Black (8)
Red/Black-White (24)
Black/Red-Green (28)
Orange/White-Blue (36)NC
Orange/Green (21)
Green/Black-White (25)
White/Red-Green (29)
Blue/White-Orange (33)
NC
Orange/Black (10)
Black/White-Red (22)
Orange/Black-White (26)
Red/Black-Green (30)
Black/White-Orange (34)
NC
1
19
2
20
Orange (5)
Black/White (12)
White/Red (17)
Red/Green (20)
Red/Black (8)
Blue/Red (19)
Red (3)
Green/White (14)
Blue/White (15)
Black (1) White (2)
Blue (6)
Orange/Red (18)
Green (4)
Black/Red (16)
White/Black (7)
Blue/Black (11)
Green/Black (9)
Red/White (13)
Orange/Black (10)
1492-CABLE➊ X 1492-CABLE➊ Y
1492-CABLE➊ Z
Publication 1492-TD008A-EN-P - March 2001
124 Digital/Analog Programmable Controller Wiring Systems
Digital Cable Specifications, Continued
Pinouts, Continued
➊ Refer to footnote on page 125.
1 White (2)Red (3)Orange (5)
White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)
Green (4)Blue (6)Red/Black (8)Black/White (12)Green/White (14)Black/Red (16)Orange/Red (18)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18 NCNC
Red (3)White(2)Black (1)
Green (4)Blue (6)
Red/Black (8)Orange/Black (10)
Black/White (12)Green/White (14)
Black/Red (16)Orange/Red (18)
Orange (5)White/Black (7)Green/Black (9)Blue/Red (19)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
1492-CAB➊ D69
1 White (2)Black (1)
Red (3)Orange (5)
White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)Blue/Red (19)
Red/Green (20)
Green (4)Blue (6)Red/Black (8)Orange/Black (10)Black/White (12)Green/White (14)Black/Red (16)Orange/Red (18)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
1492-CAB➊ E69
1492-CABLE➊ CR
1 Red (3)Green (4)Blue (6)
Red/Black (8)Orange/Black (10)
Black/White (12)Green/White (14)
Black/Red (16)Orange/Red (18)
Blue/Red (19)Red/Green (20)
Orange (5)White/Black (7)Green/Black (9)Black (1)White (2)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
1 Red (3)Green (4)Blue (6)
Red/Black (8)Orange/Black (10)
Black/White (12)Green/White (14)
Black/Red (16)Orange/Red (18)
Blue/Red (19)Red/Green (20)
Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)Black (1)White (2)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
1
Red (3)White/Black (7)
Blue/Red (19)Red/Green (20)
Blue/Black (11)Blue/White (15)
Black (1)Orange (5)Green/Black (9)Red/White (13)White/Red (17)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
Orange/Black (10
1 Red (3)Green (4)Blue (6)
Red/Black (8)Orange/Black (10)
Black/White (12)Green/White (14)
Black/Red (16)Orange/Red (18)
Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18 NCNC
1 Red (3)Green (4)Blue (6)
Red/Black (8)Orange/Black (10)
Black/White (12)Green/White (14)
Red/Green (20)
Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)
Blue/Red (19)
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
NCNC
NCNC
1 Blue (6)Orange (5)White/Black (7)Green/Black (9)Blue/Black (11)Red/White (13)Blue/White (15)White/Red (17)Blue/Red (19)
Black/White-Red (22)
White/Black-Red (23)Orange/Black-White (26)
Blue/Black-White (27)Red/Black-Green (30)
Green/Black-Orange (31)Black/White-Orange (34)
White/Red-Orange (35)
Red/Black (8)Orange/Black (10)Black/White (12)Green/White (14)Black/Red (16)Orange/Red (18)Red/Green (20)
Orange/Green (21)Red/Black-White (24)
Green/Black-White (25)Black/Red-Green (28)
White/Red-Green (29)Orange/Black-Green (32)
Blue/White-Orange (33)Orange/White-Blue (36)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
NC
NC
NC
NC
NC
NC
NC
NC
1492-CAB➊ A69 1492-CAB➊ B69 1492-CAB➊ C69
1492-CAB➊ F69 1492-CAB➊ G69
1492-CAB➊ R71
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 125
Digital/Analog Programmab le Controller Wiring SystemsDigital Cable Specifications, Continued
I/O Module-Ready Cables
The I/O module-ready cables have a pre-wired wiring arm or removable terminal block on one end to connect the programmable controller I/O module and 1240 individually colored #18 AWG conductors on the other. These cables provide the convenience of a pre-wired I/O module connector, while still allowing the flexibility to wire to standard terminal blocks.Pre-wired I/O module connectors include:
• Cat. No. 1746-N3 40-point plug-in connector (Cat. No. CABLE➊ N3)• Bulletin 1746 16-point removable terminal blocks in Red, Blue, and
Orange (Cat. No. CABLE➊ RTBR, ➊ RTBB, ➊ RTBO)• Cat. No. 1756-TBCH 36-point removable terminal block (Cat.
No. CABLE➊ TBCH)• Cat. No. 1756-TBNH 20-point removable terminal block (Cat.
No. CABLE➊ TBNH)• Cat. No. 1769-RTBN10 removable terminal block (Cat.
No. CABLE➊ RTN10)• Cat. No. 1769-RTBN18 20-point removable terminal block (Cat.
No. CABLE➊ RTN18)• Cat. No. 1771-WH 16-point wiring arm (Cat. No. CABLE➊ WH)• Cat. No. 1771-WN 32-point wiring arm (Cat. No. CABLE➊ WN)• Cat. No. 1771-WHF 16-point fused wiring arm (with fuses) (Cat.
No. CABLE➊ WHF)• Cat. No. 1771-WD 6-point wiring arm (Cat. No. CABLE➊ WD)• Cat. No. 1771-WA 8-point wiring arm (Cat. No. CABLE➊ WA)
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
Publication 1492-TD008A-EN-P - March 2001
126 Digital/Analog Programmable Controller Wiring Systems
Digital Cable Specifications, Continued
I/O Module-Ready Cables, Continued
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
I/O Module-Ready Cable Specifications
Cat. No. Cable Lengths
Insulation Rating
Number of Conductors
Conductor Size
Nominal Outer Diameter
I/O ModuleConnector
1492-CABLE➊ N3 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.2 mm (0.44") 1746-N3 (40-Point) Plug-in Connector
1492-CABLE➊ RTBB 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-RT25B Blue Removable Terminal Block
1492-CABLE➊ RTBO 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-RT25C Orange Removable Terminal Block
1492-CABLE➊ RTBR 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-RT25R Red Removable Terminal Block
1492-CABLE➊ TBCH 1.0, 2.5, 5.0 m 300V 80°C 40 #18 AWG 14.1 mm (0.55") 1756-TBCH (36-Point) Removable Terminal Block
1492-CABLE➊ TBNH 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-TBNH (20-Point) Removable Terminal Block
1492-CABLE➊ RTN10 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 9.0 mm (0.36") 1769-RTBN10 Removable Terminal Block
1492-CABLE➊ RTN18 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 9.0 mm (0.36") 1771-RTBN18 (20-Point) Removable Terminal Block
1492-CABLE➊ WA 1.0, 2.5, 5.0 m 300V 80°C 12 #18 AWG 9.0 mm (0.36") 1771-WA (8-Point/10 Terminal) Wiring Arm
1492-CABLE➊ WD 1.0, 2.5, 5.0 m 300V 80°C 12 #18 AWG 9.0 mm (0.36") 1771-WD (6-Point/12 Terminal) Wiring Arm
1492-CABLE➊ WH 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-WH (16-Point/21 Terminal) Wiring Arm
1492-CABLE➊ WHF 1.0, 2.5, 5.0 m 300V 80°C 20 #18 AWG 11.4 mm (0.45") 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm
1492-CABLE➊ WN 1.0, 2.5, 5.0 m 300V 80°C 40 #18 AWG 14.1 mm (0.55") 1771-WN (32-Point/40 Terminal) Wiring Arm
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 127
Digital Cable Specifications, Continued
I/O Module-Ready Cables, Continued
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
Wire Colors for I/O Module-Ready Cables
Reference Number
Wire ColorBase/Stripe/Stripe
Reference Number
Wire ColorBase/Stripe/Stripe
1 Black 21 Orange/Green
2 White 22 Black/White/Red
3 Red 23 White/Black/Red
4 Green 24 Red/Black/White
5 Orange 25 Green/Black/White
6 Blue 26 Orange/Black/White
7 White/Black 27 Blue/Black/White
8 Red/Black 28 Black/Red/Green
9 Green/Black 29 White/Red/Green
10 Orange/Black 30 Red/Black/Green
11 Blue/Black 31 Green/Black/Orange
12 Black/White 32 Orange/Black/Green
13 Red/White 33 Blue/White/Orange
14 Green/White 34 Black/White/Orange
15 Blue/White 35 White/Red/Orange
16 Black/Red 36 Orange/White/Blue
17 White/Red 37 White/Red/Blue
18 Orange/Red 38 Black/White/Green
19 Blue/Red 39 White/Black/Green
20 Red/Green 40 Red/White/Green
Publication 1492-TD008A-EN-P - March 2001
128 Digital/Analog Programmable Controller Wiring Systems
Digital Cable Specifications, Continued
I/O Module-Ready Cables, Continued
Below is the wire color table for I/O module-ready cables. Each colored conductor is given a reference number in the table. The reference number is used in the illustrations that follow to indicate the corresponding screw terminal.
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
1 2
39 40
24
81012141618202224262830323436
6
13
7911131517192123252729313335
5
135791113151719
2468
101214161820
13
7
13
5
9 11
15171921232527293133353739
34
40
2468
101214161820222426283032
3836
123
45
14
6789
10111213
151617181920
123
45678 9 1011121314151617181920
1
23
4
5
789
10
11
12
6
1
2
3
4
5
7
8
9
10
6
2
4
6
8
10
14
16
18
12
1
3
5
7
9
13
15
17
11
1492-CABLE➊ N3 1492-CABLE➊ TBCH 1492-CABLE➊ TBNH 1492-CABLE➊ WN 1492-CABLE➊ WH 1492-CABLE➊ WF
1492-CABLE➊ WD 1492-CABLE➊ WA 1492-CABLE➊ RTBR1492-CABLE➊ RTBB1492-CABLE➊ RTBO
1
GreenRed
BlueRed/Black
Orange/BlackBlack/White
WhiteBlack
OrangeWhite/BlackGreen BlackBlue/Black
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
1 BlackWhite
GreenRed
BlueRed/Black
Orange/BlackBlack/White
Green/WhiteBlack/Red
Orange/RedRed/Green
OrangeWhite/BlackGreen/BlackBlue/BlackRed/WhiteBlue/WhiteWhite/RedBlue/Red
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
1492-CAB➊ RTN10 1492-CAB➊ RTN18
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 129
Digital Cable Specifications, Continued
IFM-Ready Cable Specifications
IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (Cat. Nos. CABLE➊ P and CABLE➊ Q, respectively). These cables allow the IFM to be used in specialty applications that require a custom connection.
Each colored conductor is connected to one pin of the molded cable connector as listed in the tables below.
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.
IFM-Ready Cable Specifications
Cat. No. Cable Lengths Insulation Rating
Number of Conductors
Conductor Size
Nominal Outer Diameter
Current/Conductor
CompatibleIFM Cat. Nos.
1492-CABLE➊ P 1.0, 2.5, 5.0 m 300V 80°C 20 #22 AWG 9.0 mm (0.36") 2 A 1492-IFM20_ _ _1492-XIM20_ _ _
1492-CABLE➊ Q 1.0, 2.5, 5.0 m 300V 80°C 40 #22 AWG 11.7 mm (0.46") 2 A 1492-IFM40_ _ _1492-XIM40_ _ _
1492-CABLE➊ P
Connector Pin Number
Wire ColorBase/Stripe/Stripe
Connector Pin Number
Wire ColorBase/Stripe/Stripe
1 Black 11 Blue/Black2 White 12 Black/White3 Red 13 Red/White4 Green 14 Green/White5 Orange 15 Blue/White6 Blue 16 Black/Red7 White/Black 17 White/Red8 Red/Black 18 Orange/Red9 Green/Black 19 Blue/Red10 Orange/Black 20 Red/Green
Publication 1492-TD008A-EN-P - March 2001
130 Digital/Analog Programmable Controller Wiring Systems
Digital Cable Specifications, Continued
IFM-Ready Cable Specifications, Continued
➊ Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.
1492-CABLE➊ Q
Connector Pin Number
Wire ColorBase/Stripe/Stripe
Connector Pin Number
Wire ColorBase/Stripe/Stripe
1 Black 21 Orange/Green
2 White 22 Black/White/Red
3 Red 23 White/Black/Red
4 Green 24 Red/Black/White
5 Orange 25 Green/Black/White
6 Blue 26 Orange/Black/White
7 White/Black 27 Blue/Black/White
8 Red/Black 28 Black/Red/Green
9 Green/Black 29 White/Red/Green
10 Orange/Black 30 Red/Black/Green
11 Blue/Black 31 Green/Black/Orange
12 Black/White 32 Orange/Black/Green
13 Red/White 33 Blue/White/Orange
14 Green/White 34 Black/White/Orange
15 Blue/White 35 White/Red/Orange
16 Black/Red 36 Orange/White/Blue
17 White/Red 37 White/Red/Blue
18 Orange/Red 38 Black/White/Green
19 Blue/Red 39 White/Black/Green
20 Red/Green 40 Red/White/Green
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 131
Analog IFM Specifications
For all AIFM dimensions, refer to page 160.For general Adhesive Label Card information, refer to page 162.For Field-Side Wiring Diagrams, refer to the Wiring System web page at http://www.ab.com/catalogs/b113. Refer to page 202 for specific platform web site information. Refer to the online documentation for new product information.
Symbols and Terminal Identification Conventions Used Throughout the Pinout Section
1492-AIFM Field-Side Terminal ➊
1492 Pre-Wired Cable
I/O Module Connection
Fuse and Blown Fuse Indicator
One-Pole DIP Switch
Two-Pole DIP Switch
1492-AIFM and Cable Connection (D-Shell Pin)
Test Point
➊ Field-Side Terminal Identification Convention:
AIFMCat. No.
Page No. for Specifications,
Application Notes, and Pinout
Page No. for
Adhesive Label Card
AIFMCat. No.
Page No. for Specifications,
Application Notes, and Pinout
Page No. for
Adhesive Label Card
AIFMCat. No.
Page No. for Specifications,
Application Notes, and Pinout
Page No. for
Adhesive Label Card
1492-AIFM4-3 132 191 1492-AIFM4C-F-5 136 190 1492-AIFM16-F-5 140 1971492-AIFM6S-3 133 192 1492-AIFM4I-F-5 137 190 1492-AIFMQS 141 1981492-AIFM8-3 134 193 1492-AIFM8-F-5 138 195 1492-AIFMPI 142 1991492-AIFM6TC-3 135 192 1492-AIFM16-F-3 139 196 — — —
B1 B2 B3 B4 B5 . . .
A1 A2 A3 A4 A5 . . .
C1 C2 C3 C4 C5 . . .
B1 B2 B3 B4 B5 . . .
A1 A2 A3 A4 A5 . . .
Publication 1492-TD008A-EN-P - March 2001
132 Digital/Analog Programmable Controller Wiring Systems
1492-AIFM4-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 191. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. DIP Switches Selectable resistors are available to current limit the Cat. Nos. 1771-OFE2 and -OFE3 output circuits. By opening the switch (off or down position), 250 Ω series impedance is inserted into the output circuit. Default switch position is on/closed/no series impedance. Do not exceed maximum loop impedance of output module (1200 Ω for -OFE2; 450 Ω for -OFE3).
4. Test Points With optional 250 Ω series impedance in output circuit (refer to DIP Switches), test points can be used to measure loop voltage/current. Refer to the Pinout for test point circuit location.
5. Shield Terminals Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
6. Dimensions Refer to page 160.
Pinout
1492-AIFM4-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Shield Common
4
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
A32
B3
A7
B7
A1
A2
A5
A6
B1
B2
B5
B6
A4A8
B4
B8
1
8
15
14
13
12
11
10
9
TP1 TP2
TP3 TP4
TP5 TP6
TP7 TP8
D-Shell Housing
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 133
1492-AIFM6S-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 192. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Shield Terminals Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
4. Dimensions Refer to page 160.
Pinout1492-AIFM6S-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Shield Common
6
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B113
A1
B2
B3
A3
B4
B5
A5
B6
B7
A7
B8
B9
A9
B10
B11
12
25
24
11
23
22
9
21
19
D-Shell Housing
A11
B12
A2A4
A6A8A10A12
6
18
17
4
16
15
2
14
Publication 1492-TD008A-EN-P - March 2001
134 Digital/Analog Programmable Controller Wiring Systems
1492-AIFM8-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 193. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Extra Terminals Eight field-side terminals are jumpered together on the AIFM. For some I/O modules, the terminals are also internally connected to module common through the pre-wired cable. Refer to the AIFM and ACABLE pinouts.
4. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
5. Dimensions Refer to page 160.
Pinout
1492-AIFM8-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Device Common
8
No. of Terminals per Shield Common
8
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B13
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
2
1
14
15
16
17
18
12
13
D-Shell Housing
A9A10
A11A12
A13
A14A15A16
25
24
23
22
20
21
A1A2
A3A4
A5
A6A7A8
4
6
810
19
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 135
1492-AIFM6TC-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 192. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Shield Terminals Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
4. Cold Junction Compensation This AIFM contains on-board cold junction compensation through a thermistor and isothermal bar mounted to the field-side terminals. Do not install the additional cold junction sensor (provided with the Cat. No. 1756-IT6I thermocouple input module) on the removable terminal block of the pre-wired cable.
5. Dimensions Refer to page 160.
Pinout
1492-AIFM6TC-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…132V AC/DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
—
No. of Terminals per Shield Common
6
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B113
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
A7
A1
A3
A5
25
24
23
22
21
19
18
17
16
D-Shell Housing
15
14
6
20
12
11
A2A4
A6A8A10
A12
A9
A11
9
4
2
T
Publication 1492-TD008A-EN-P - March 2001
136 Digital/Analog Programmable Controller Wiring Systems
1492-AIFM4C-F-5
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 190. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.
5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.
6. Test Points When using a two-wire transmitter, test points can be used to measure input loop current. Refer to the Pinout for test point circuit location.
7. Extra Terminals Four field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections.
8. Shield Terminals Four field-side terminals are jumpered together on AIFM and internally connected to the D-shell housing.
9. Dimensions Refer to page 160.
Pinout
1492-AIFM4C-F-5 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V DC
Maximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 A
Maximum Current (per Module) 12 A
Indicator Circuit Current (Nominal) 2 mA
No. of Terminals per Device Common 4
No. of Terminals per Shield Common 4
Wire Range (Rated Cross Section) ➋ #22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)
Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12
No. of Wires 3 3 3 2 1 1
B18
A8
B2
A5
B3
B4
B5
B6
B7
B8
B9
B10
B11
A2
A1
B12
15
14
13
12
11
2
10
9
1
TP1 TP2
TP3 TP4
D-Shell Housing
A12
A9
....
....
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 137
1492-AIFM4I-F-5
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 190. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.
5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.
6. Test Points When using a two-wire transmitter, test points can be used to measure input loop current. Refer to the Pinout for test point circuit location.
7. Extra Terminals Four field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections.
8. Shield Terminals Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
9. Dimensions Refer to page 160.
Pinout
1492-AIFM4I-F-5 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common
4
No. of Terminals per Shield Common
4
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
B18
A8
B2
A5
B3
B4
B7
B5
B6
B8
B9
B10
B11
A4
A1
B12
15
14
13
2
12
11
10
9
1
TP1 TP2
TP7 TP8
D-Shell Housing
A12
A9
.....
.....
.....
Publication 1492-TD008A-EN-P - March 2001
138 Digital/Analog Programmable Controller Wiring Systems
1492-AIFM8-F-5
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 195. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.
5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.
6. Extra Terminals Nine field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections.
7. Shield Terminals Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
8. Dimensions Refer to page 161.
Pinout
1492-AIFM8-F-5 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common
9
No. of Terminals per Shield Common
18
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
C1
C16
C2
C15
C3
C4C5
C6C7
C8C9
C10
C11
C13
C12
C14
D-Shell Housing
B2
B1
B9
B10
B18
A1
A18
3
21
1415
1617
1812
13
25
2423
2220
21
6
19
.....
.....
.....
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 139
1492-AIFM16-F-3
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 196. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.
5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.
6. Shield Terminals Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
7. Dimensions Refer to page 161.
Pinout
1492-AIFM16-F-3 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 10…30V DC
Maximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit) 2 A
Maximum Current (per Module) 12 A
Indicator Circuit Current (Nominal) 2 mA
No. of Terminals per Shield Common
18
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)
Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12
No. of Wires 3 3 3 2 1 1
B2
B16
B3
B15
B4
B5
B6
B7
B8
B9
B10
B11
B13
B12
B14
D-Shell Housing
B18
B17
B1
C1
C16
A1
A18
3
2
1
14
15
16
17
18
12
13
25
24
23
22
20
21
4
6
810
19 .....
.....
Publication 1492-TD008A-EN-P - March 2001
140 Digital/Analog Programmable Controller Wiring Systems
1492-AIFM16-F-5
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 197. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
4. Isolation The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. All inputs within a group must reference the same power source.
5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together.
6. Extra Terminals Sixteen field-side terminals (C9C16 on TB1 and TB2) are internally jumpered on the AIFM and connected to module common. Eighteen field-side terminals (B10B18 on TB1 and TB2) are internally jumpered on the AIFM and can be used for power source common connections. There are two field-side terminals (A17 and A18 on TB1) that can be externally jumpered to connect the two groups of field-side terminals.
7. Shield Terminals Sixteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
8. Dimensions Refer to page 161.
Pinout
1492-AIFM16-F-5 Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 2 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Device Common
16
No. of Terminals per Shield Common
16
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
C1
B10
C2
B9
C3
C4
C5
C6
C7
C8
C9
C16
B1
A17
B2
D-Shell Housing
A18
B18
A1
A8
3
2
1
14
15
16
17
18
C1
B10
C2
B9
C3
C4
C5
C6
C7
C8
C9
C16
B1
B2
B18
A1
12
13
25
24
23
22
20
21
4
6
810
19 .....
.....
...
...
....
....
...
A8
...
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 141
1492-AIFMQS
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 198. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 3 A per input, 12 A per AIFM.
4. Isolation The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. All inputs within a group must reference the same power source.
5. Extra Terminals Four field-side terminals (on TB1) are internally jumpered on the AIFM and connected to module common. Four field-side terminals (on TB1) are internally jumpered on the AIFM and can be used for power source common connections.
6. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
7. Dimensions Refer to page 161.
Pinout
1492-AIFMQS Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approvedVoltage Rating 10…30V DCMaximum Peak Voltage ➊ 600VpMaximum Current (per Circuit) 3 AMaximum Current (per Module) 12 AIndicator Circuit Current (Nominal) 2 mANo. of Terminals per Shield Common
8
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
+INT 1
-INT 1
+RET 1
-RET 1
+OUT 1
OUT COM
+INT 2
-INT 2
+RET 2
-RET 2
+OUT 2
OUT COM
+INT 3
-INT 3
+RET 3
-RET 3
+OUT 3
OUT COM
+INT 4
-INT 4
+RET 4
-RET 4
+OUT 4
OUT COM
COM
LDT COM
LDT COM
GND
SH
SH
+ Interrogate 1
- Interrogate 1
+ Return 1
- Return 1
Drive Output 1
Drive Common
+ Interrogate 2
- Interrogate 2
+ Return 2
- Return 2
Drive Output 2
+ Interrogate 3
- Interrogate 3
+ Return 3
- Return 3
Drive Output 3
Drive Common
+ Interrogate 4
- Interrogate 4
+ Return 4
- Return 4
Drive Output 4
LDT Common
LDT Common
DRAIN
12
24
13
25
11
21
10
22
8
23
9
18
20
19
17
5
6
15
4
16
2
7
1
3
2
3
1
11
17
19
20
12
25
26
10
5
15
6
8
9
4
14
23
24
18
21
13
22
-V
-V1F
-V4F
+V
+V1F
+V4F
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
White/Brown
White/Gray
Red/Orange
Red/Blue
Green/White
Brown/White
Gray/White
Orange/Red
Red/Green
Green/Red
Red/Brown
Brown/Red
Red/Gray
Gray/Red
Black/Blue
Blue/Black
Black/Orange
Orange/Black
Blue/Red
Publication 1492-TD008A-EN-P - March 2001
142 Digital/Analog Programmable Controller Wiring Systems
1492-AIFMPI
➊ For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand.
➋ Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
2. Wiring Refer to the Label Section on page 199. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
3. Fusing Two fuse holders for the outputs are included with the AIFM. Eight fuses (0.25 A, 5 x 20 mm) are included with the fused supply inputs. Do not exceed 2 A per output.
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source.
5. Jumpers J0J7 provide the option of connecting the negative inputs to the return. J8 commons the shield to the return. Default switch position is OPEN/OFF/NOT jumpered together.
6. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.
7. Dimensions Refer to page 161.
Pinout
Refer to page 143.
1492-AIFMPI Specifications
Approvals • UL Component Recognized (File E113724 Guide NRAQ2)
• UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2)
• CE Approved• Factory Mutual Listed
(File J.I. 3000590) FM approved
Voltage Rating 0…30V DCMaximum Peak Voltage ➊ 600Vp
Maximum Current (per Circuit)
2 A
Maximum Current (per Module)
12 A
Indicator Circuit Current (Nominal)
2 mA
No. of Terminals per Device Common
1
No. of Terminals per Shield Common
8
Wire Range (Rated Cross Section) ➋
#22…#12 AWG (0.2…4 mm2)
Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque
3.5…4.5 lb-in. (0.38…0.50 Nm)
Operating Temperature Range
0…+60°C
AWG #22 #20 #18 #16 #14 #12No. of Wires 3 3 3 2 1 1
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 143
1492-AIFMPI, Continued
Pinout, Continued
TB
B2
B4
F0
F1
B19
B9
B6
B8
F2
F3
B11F4
B13F5
B15F6
B17
B18
F7
F8
F9OUT 1
V1RTN
RTNOUT 0
RTNOUT 1
OUT 0
V1+DC
V0+24
2412
25
B20
A18
A19
A20
13
+VFUSED 0-7
CN TB
+
–
1
J032
3 A315 A4
4 A114 A2
+1–1
+0–0
2 A516 A61 A717 A88 A1018 A11
7 A1219 A136 A1420 A155 A1621 A17
+2–2
+3–3
+4–4
+5–5
+6–6
+7–7
CHANNEL 0
CHANNEL
0
1
IN
IN
IN
IN
IN
IN
IN
IN
2
3
4
5
6
7
+
–
1
J732 CHANNEL 7
B1
B3
922
SHELL
SHIELDIN 0...7
1
J832
B5
B7
B10
B12
B14
B16
A9 V0RTN
Publication 1492-TD008A-EN-P - March 2001
144 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsAnalog Cable Specifications
Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Analog pre-wired cables, when used with an AIFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The analog ready-to-wire cables provide one end of the cable pre-terminated for an AIFM (AIFM-ready cable).
Pre-Wired Cables
Specifications
The pre-wired cables have a Bulletin 1746 Removable Terminal Block, Bulletin 1756 Removable Terminal Block, Bulletin 1769 Removable Terminal Block, or Bulletin 1771 Wiring Arm on one end and a D-shell on the other to connect to the AIFM. All analog cables have an overall shield and most have #22 AWG twisted pairs for additional noise immunity. In addition, most analog cables have prepared ring lugs on the drain wire for convenient grounding of the cable shield to the programmable controller chassis. The broad offering of analog pre-wired cables supports over 26 different Bulletin 1746, 1756, 1769, and 1771 analog, RTD, and thermocouple I/O modules.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 145
Analog Cable Specifications, Continued
Pre-Wired Cables, Continued
➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m and 5.0 m. To order, insert the desired cable length code into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable for the 1746-NI4 I/O Module. Also refer to Build-to-Order Length Cables on page 44.
➋ All pre-wired analog cables have an overall shield. On 1492-ACABLE➊ C and 1492-ACABLE➊ D, the drain wire is connected to the shield terminal on the I/O module connector. All other 1492-ACABLEs have a ring lug on the 7.87" (200 mm) exposed drain wire at the I/O module end of the cable.
➌ Not every connection is always used.
Analog Pre-Wired Cable Specifications
Cat. No. andLength ➊
Standard Cable Lengths
I/O ModuleConnector
AIFM Connector
No. of Conductors ➋➌
Insulation Rating
Conductor Size
Nominal Outer Diameter
1492-ACABLE➊ A 0.5, 1.0, 2.5, 5.0 m 1746-RT28 12-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ B 0.5, 1.0, 2.5, 5.0 m 1746-RT26 2-Position and 1746-RT27 8-Position Removable Terminal Block
15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ C 0.5, 1.0, 2.5, 5.0 m 1746-RT25G Green Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ D 0.5, 1.0, 2.5, 5.0 m 1746-RT25G Green Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ E 0.5, 1.0, 2.5, 5.0 m 1771-WG (21 terminal) 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")1492-ACABLE➊ F 0.5, 1.0, 2.5, 5.0 m 1771-WG (21 terminal) Wiring Arm 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ G 0.5, 1.0, 2.5, 5.0 m 1771-WC (10 terminal) Wiring Arm 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ H 0.5, 1.0, 2.5, 5.0 m 1771-WF (18 terminal) Wiring Arm 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ J 0.5, 1.0, 2.5, 5.0 m 1771-WF (18 terminal) Wiring Arm 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ L 0.5, 1.0, 2.5, 5.0 m 1746-RT28 12-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ M 0.5, 1.0, 2.5, 5.0 m 1757-PIM 36-Position Removable Terminal Block 25-pin D-shell 11 Twisted Pairs 300V 80°C 22 AWG 11.5 mm (0.45")
1492-ACABLE➊ Q 0.5, 1.0, 2.5, 5.0 m 1746-QS (26 terminal D-shell) 25-pin D-shell 12 Twisted Pairs 300V 80°C 22 AWG 10.2 mm (0.40")
1492-ACABLE➊ X 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")1492-ACABLE➊ Y 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ Z 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACAB➊ A46 0.5, 1.0, 2.5, 5.0 m 1746-RT25G Green Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 10.2 mm (0.40")
1492-ACABLE➊ TA 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ TB 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ TC 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ TD 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ UA 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ UB 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ UC 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ UD 0.5, 1.0, 2.5, 5.0 m 1756-TBCH 36-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ VA 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 15-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")1492-ACABLE➊ VB 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 15-pin D-shell 20 Conductors 300V 80°C 22 AWG 8.43 mm (0.332")
1492-ACABLE➊ WA 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ WB 0.5, 1.0, 2.5, 5.0 m 1756-TBNH 20-Position Removable Terminal Block 25-pin D-shell 9 Twisted Pairs 300V 80°C 22 AWG 6.78 mm (0.267")
1492-ACABLE➊ AA69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN10 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")1492-ACABLE➊ AB69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN10 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ BA69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ BB69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
1492-ACABLE➊ BC69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")1492-ACABLE➊ BD69 0.5, 1.0, 2.5, 5.0 m 1769-RTBN18 20-Position Removable Terminal Block 15-pin D-shell 5 Twisted Pairs 300V 80°C 22 AWG 7.44 mm (0.293")
Publication 1492-TD008A-EN-P - March 2001
146 Digital/Analog Programmable Controller Wiring Systems
Analog Cable Specifications, Continued
Pinouts
Analog Pre-Wired Cables
The following diagrams indicate how the analog pre-wired cables are connected on both ends. The description listed first is the wire color of the conductor connected to the screw terminal on the respective Wiring Arm or Removable Terminal Block. The number that follows in parentheses is the corresponding pin number in the D-shell connector on the other end.
No Connection
Twisted Pair Jumper Wire
Individual Conductor
Base Color Stripe Color
Blue (24)
Black (23)
White/Green (22)
White/Red (19)
NC 20 or 40 Connector Pin Number
Shield
Output Pin Connector Definition
1111
8 13
25
14
15
9
15-Pin D-Shell Connector 25-Pin D-Shell Connector
AIFM Mating Connector Definition
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 147
Analog Cable Specifications, Continued
Pinouts, Continued
Red (3)Black (2)
NC
White (1)Black (14)
Green (15)Black (16)
Blue (17)Black (18)
Yellow (12)Black (13)
Brown (25)Black (24)
Orange (23)Black (22)
Red (20)White (21)
Drain
White/Violet (25)
NC
Blue (13)
White/Orange (21)
Orange (9)
Green (12)
White/Yellow (22)
NC
NC
White/Blue (24)
White/Green (23)
Yellow (11)
NC
White/Red (19)
White/Brown (18)
Red (6)
Drain
NC
Yellow (2)
Black (1)
White (14)
Black (13)
Red (8)Black (15)
Blue (10)
Black (9)
Green (12)Black (11)
01
01
2
3
4
5
6
7
Red (8)
NCBlack (15)
White (14)
Yellow (2)
Black (13)
Green (12)
NCBlack (11)
Blue (10)
Black (1)Black (9)
01
2
34
5
6
78
9
1011
1492-ACABLE___A 1492-ACABLE___B 1492-ACABLE___C
1492-ACABLE___D
Red (3)
Black (2)
NC
White (1)
Black (14)
Green (15)
Black (16)
Blue (17)
Black (18)
Yellow (12)
Black (13)
Brown (25)
Black (24)
Orange (23)
Black (22)
Red (20)
White (21)
NC
NC
Red (6)
Green (19)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Red (3)
Brown (2)
Black (1)
White (14)
Orange (4)
White/Black (15)
White/Brown (16)
White/Red (17)
White/Orange (18)
Blue (10)
Violet (12)
Gray (13)
White/Black/Brown (25)
White/Gray (24)
Green (8)
White/Violet (23)
White/Blue (22)
White/Yellow (20)
White/Green (21)
Yellow (6)
NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1492-ACABLE___E 1492-ACABLE___F
Publication 1492-TD008A-EN-P - March 2001
148 Digital/Analog Programmable Controller Wiring Systems
Analog Cable Specifications, Continued
Pinouts, Continued
NCNC
18
16
14
12
10
8
6
4
2
Red (3)Black (2)White (1)Black (14)Green (15)Black (16)Blue (17)Black (18)
Yellow (12)Black (13)Brown (25)Black (24)Orange (23)Black (22)Red (20)White (21)
White (14)
Black (13)
Red (8)
Black (15)
Blue (10)
Black (9)
Green (12)
Black (11)
NC
NC
A
0
1
2
3
4
5
6
7
B
2
36
1
35
Red (4) (3) White
Black (14)(15) Black
Black (18)
Black (16)Green (2)(1) Blue
(17) Black
NCNC
NCNC
NCNCNC
NCNC
NC
NC
Yellow (8)(7) Brown(19) Black
NCNC
NCNC
Orange (6)Black (20)
(5) Red(21) White
Red (12)Green (25)
NC(24) Red
(13) Blue
18
16
14
12
10
8
6
4
2
White/Violet (25)Green (12)Blue (13)White/Green (23)Yellow (11)White/Blue (24)White/Orange (21)Orange (9)White/Yellow (22)White/Brown (18)Red (6)White/Red (19)White (16)Brown (4)White/Black (17)Violet (14)Black (2)Gray (15)
1492-ACABLE___H 1492-ACABLE___J
Red (8)
Black (15)
White (14)Black (13)
NC
NC
Green (11)Black (2)
NC
NC
Blue (9)
Black (1)
01
2
34
5
6
78
9
1011
1492-ACABLE___L1492-ACABLE___G
Black/Orange (2)Orange/Black (1)
Green/White (23)White/Green (11)
Red/Blue (8)
Blue/Red (7)
Blue/Black (16)
918
26
110 19
Black/Blue (4)
Gray/Red (15)
Red/Gray (15)
Gray/White (22)
White/Gray (22) Brown/White (22)
White/Brown (9)
Red/Brown (5)Brown/Red (17)
Red/Green (20)Green/Red (19)
Orange/Red (18)Red/Orange (6)
Orange/White (25)White/Orange (13)
Blue/White (24)White/Blue (12)
1492-ACABLE___Q1492-ACABLE___M
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 149
Analog Cable Specifications, Continued
Pinouts, Continued
1Red (3)Brown (2)Black (1)
White(14)Orange (4)Yellow (6)
White/Black (15)White/Brown (16)
White/Red (17)White/Orange (18)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
Green (8)Blue (10)
Violet (12)Gray (13)
White/Yellow (20)White/Blue (22)
White/Violet (23)
White/Gray (24)White/Black/Brown (25)
White/Green (21)
1Red (3)Black (2)White (1)Black(14)
Yellow (6)Black (21)
Green (15)Black (16)Blue (17)
Black (18)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
1Red (3)Black (2)White (1)Black(14)
Yellow (6)Black (21)
Green (15)Black (16)Blue (17)
Black (18)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
1Red (3)Black (2)White (1)Black(14)
Red (6)Green (19)
Green (15)Black (16)Blue (17)
Black (18)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
Yellow (12)Black (13)
Red (20)Black (22)
Orange (23)
Black (24)Brown(25)
White (21)
1Red (3)J1Black (2)
White (1)Black(14)
Red (6)Green (19)
Green (15)Black (16)Blue (17)
Black (18)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
J2
J3
J4
J5
J6
J7
J8
Yellow (12)Black (13)
Red (20)Black (22)
Orange (23)
Black (24)Brown(25)
White (21)
1Red (3)Brown (2)Black (1)
White (14)
White/Black (15)White/Brown (16)
White/Red (17)White/Yellow (18)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
Yellow (6)
Green (8)
Orange (4)
Violet (12)Gray (13)
Blue (10)White/Gray (24)
White/Black/Brown (25)
White/Yellow (20)White/Blue (22)
White/Violet (23)
White/Green (21)
1Red (3)Black (1)
White/Black (15)White/Red (17)White/Blue (22)Orange (4)
Yellow (6)Violet (12)
White/Black/Brown (25)White/Violet (23)
White/Yellow (20)
White/Brown (16)Brown (2)Gray (13)
White/Red-Blue (1)Orange/Green (1)Green/Black-White (1)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
20
32
34
36
1Red (3)Black (1)
White/Black (15)White/Red (17)
Orange (4)Yellow (6)
Violet (12)White/Black/Brown (25)
White/Violet (23)White/Yellow (20)
White (14)
Gray (13)White/Gray (24)White/Blue (22)
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
White/Brown (16)
Brown (2)
White/Orange (18)
White/Green (21)
1492-ACABLE___TA
1492-ACABLE___UA
1492-ACABLE___UB
1492-ACABLE___TB
1492-ACABLE___TC 1492-ACABLE___TD
1492-ACABLE___UC 1492-ACABLE___UD
Publication 1492-TD008A-EN-P - March 2001
150 Digital/Analog Programmable Controller Wiring Systems
Analog Cable Specifications, Continued
Pinouts, Continued
Red (8)Black (15)
Black (13)White (14)
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
Green (12)Black (11)
Black (9)Blue (10)
White/Blue (24)
Yellow (11)
White/Green (23)
White/Red (19)
Red (6)
White/Brown (18)
NC
Gray (15)
Black (2)
Violet (14)
Blue (13)
Green (12)
White/Violet (25)
White/Yellow (22)
Orange (9)
White/Orange (21)
NC
White/Black (17)
Brown (4)
White (16)
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
Black (18)
Blue (24)
NC
Black (23)
Yellow (19)
Brown (6)Black (20)
Orange (15)
NC
Black (14)
Red (13)
NC
Black (25)
White (22)
NC
Black (21)
Green (17)
NC
Black (16)
NC
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
Blue (24)
Black (23)
Yellow (19)
Black (18)
NC
Black (14)
NC
Red (13)
Black (25)
White (22)
Black (21)
Green (17)
Black (16)
Orange (15)
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
Red (8)
Black (15)Black (13)White (14)
Green (12)Black (11)Black (9)
Blue (10)
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
Yellow (12) Red (3)
Black (24)Black (13)
Brown (25)
Orange (23)
Black (22)White (21)
Black (2)Black (14)White (1)
Red (6)
Black (18)Black (16)
Green (15)
Blue (17)Red (20)
Green (19)
Yellow (12) Red (3)
Black (24)Black (13)
Brown (25)
Orange (23)
Black (22)
White (21)
Black (2)Black (14)White (1)
Red (6)
Black (18)Black (16)
Green (15)
Blue (17)Red (20)
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
NC
NC
Green (19)
1492-ACABLE___VA 1492-ACABLE___VB
1492-ACABLE___WA 1492-ACABLE___WB
1492-ACABLE___X 1492-ACABLE___Y 1492-ACABLE___Z
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 151
Analog Cable Specifications, Continued
Pinouts, Continued
Red (8)
White (14)
Green (12)
Blue (10)Black (9)
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
Brown (2)Red(3)
Black (1)
Violet (15)
White (17)
Orange (6)
Yellow (12)
White/Violet (25)
White/Green (23)
White/Red (20)
Blue (14)
Gray (16)
White/Black (18)
White/Brown (19)
Green (13)
White/Blue (24)
White/Yellow (22)
White/Orange (21)
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
Red (8)
White (14)
Green (12)
Blue (10)
Black (9)
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
Red (8)
Black (15)
Black (13)
White (14)
1
3
5
7
9
2
4
6
8
10
NC
NCNC
NC
NCNC
Red (8)Black (15)
Black (13)White (14)
1
3
5
7
9
2
4
6
8
10NC
NC
NC
Red (8)
White (14)
NC
NC
NC
Red (8)
White (14)
Green (12)
Blue (10)
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
NC
NC
NC
NC
NC
NC
NCNC
NCNC
Black (15)
Black (13)
Black (11)
Black (9)
Red (8)
White (14)
Green (12)
Blue (10)
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
NC
NC
NC
NCNC
Black (15)
Black (13)
Black (11)
Black (9)
1492-ACAB___AB69
1492-ACAB___BA691492-ACAB___A46
1492-ACAB___AA69
1492-ACAB___BB69 1492-ACAB___BC69 1492-ACAB___BD69
Publication 1492-TD008A-EN-P - March 2001
152 Digital/Analog Programmable Controller Wiring Systems
DimensionsDigital IFM Mating Connector
Analog D-Shell Connector
Digital IFM DimensionsCat. Nos. 1492-IFM20F, 1492-IFM20D24, 1492-IFM20D120
Cat. Nos. 1492-IFM20FN, 1492-IFM20D24N, 1492-IFM20D120N
54.4 mm(2.15 in.)
39 mm(1.54 in.)
11.7 mm(0.46 in.)
10 mm(1.40 in.)
35.9 mm(1.42 in.)
29 mm(1.15 in.)
38 mm(1.50 in.)
34.3 mm(1.35 in.)
10 mm(1.40 in.)
9.0 mm(0.36 in.)
20-Point Cable Dimensions 40-Point Cable Dimensions
1.8 in.44 mm
1.6 in.39 mm
0.7 in.17 mm
2.4 in.60 mm
0.7 in.17 mm
1.6 in.39 mm
2.3 in.58 mm
2.9 in.73 mm
15-Pin D-Shell Dimensions 25-Pin D-Shell Dimensions
4.33 in.(110 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
2.36 in.(60 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 153
Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM20F-2, 1492-IFM20D24-2, 1492-IFM20D24A-2, 1492-IFM20D120-2,
1492-IFM20D120A-2, 1492-IFM20D240-2, 1492-IFM20D240A-2
Cat. Nos. 1492-IFM20F-3, 1492-IFM20D24-3
Cat. Nos. 1492-IFM20DS24-4, 1492-IFM20DS120-4
Cat. Nos. 1492-IFM20F-F-2, 1492-IFM20F-F24-2, 1492-IFM20F-F120-2, 1492-IFM20F-F120A-2, 1492-IFM20F-FS120-4, 1492-IFM20F-FS240-4, 1492-IFM20F-F24A-2
4.33 in.(110 mm)
2.19 in.(55.5 mm) 1.67 in.
(42.5 mm)
2.78 in.(70.5 mm)
3.27 in.(83 mm)
4.33 in.(110 mm)
2.74 in.(69.5 mm)
3.27 in.(83 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
2.78 in.(70.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm) 2.19 in.
(55.5 mm)
4.33 in.(110 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
4.33 in.(110 mm)
Publication 1492-TD008A-EN-P - March 2001
154 Digital/Analog Programmable Controller Wiring Systems
Digital IFM Dimensions, Continued Cat. No. 1492-IFM20F-F240-2
Cat. Nos. 1492-IFM20F-FS-2, 1492-IFM20F-FS24-2, 1492-IFM20F-FS120-2
Cat. Nos. 1492-IFM20F-FS24A-4, 1492-IFM20F-FS120A-4
Cat. Nos. 1492-IFM40F, 1492-IFM40D24
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
4.72 in.(120 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
2.36 in.(60 mm)
2.19 in(55.5 mm)
2.78 in(70.5 mm)
3.15 in(80 mm)
1.67 in(42.5 mm)
3.27 in(83 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
4.33 in.(110 mm)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 155
Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM40F-2, 1492-IFM40D24-2, 1492-IFM40D24A-2, 1492-IFM40D120-2,
1492-IFM40D120A-2
Cat. Nos. 1492-IFM40F-3, 1492-IFM40D24-3
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
8.27 in.(210 mm)
2.74 in.(69.5 mm)
3.27 in.(83 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
2.78 in.(70.5 mm)
8.27 in.(210 mm)
Publication 1492-TD008A-EN-P - March 2001
156 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsDigital IFM Dimensions, Continued Cat. Nos. 1492-IFM40DS24-4, 1492-IFM40DS120-4
Cat. Nos. 1492-IFM40DS24A-4, 1492-IFM40DS120A-4, 1492-IFM40DS240A-4
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm) 2.19 in.
(55.5 mm)
6.69 in.(170 mm)
6.69 in.(170 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm) 2.19 in.
(55.5 mm)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 157
Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM40F-F-2, 1492-IFM40F-F24-2, 1492-IFM40F-F120-2
Cat. Nos. 1492-IFM40F-FS120-4, 1492-IFM40F-FS120A-4, 1492-IFM40F-FS24-4, 1492-IFM40F-FS24A-4, 1492-IFM40F-FS240-4
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
8.27 in.(210 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm) 2.19 in.
(55.5 mm)
7.09 in.(180 mm)
Publication 1492-TD008A-EN-P - March 2001
158 Digital/Analog Programmable Controller Wiring Systems
Digital IFM Dimensions, Continued Cat. Nos. 1492-IFM40F-FS-2, 1492-IFM40F-FS24-2, 1492-IFM40F-FS120-2
Digital XIM Dimensions Cat. No. 1492-XIM4024-8R
Cat. No. 1492-XIM4024-16R
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
3.27 in.(83 mm)
2.78 in.(70.5 mm)
4.72 in.(120 mm)
6.30 in.
(160 mm)
2.19 in.
(55.5 mm) 1.67 in.(42.5 mm)
3.27 in.
(83 mm)
2.78 in.
(70.5 mm)
2.37 in.
(60.2 mm)
3.27 in.
(83 mm)
9.06 in.
(230 mm)
2.78 in.
(70.5 mm)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 159
Digital XIM Dimensions, Continued
Cat. Nos. 1492-XIM2024-8R, 1492-XIM20120-8R
Cat. Nos. 1492-XIM24-8R, 1492-XIM120-8R
Cat. No. 1492-XIMF-2
Cat. Nos. 1492-XIMF-F24-2, 1492-XIMF-F120-2
2.19 in.
(55.5 mm) 1.67 in.
(42.5 mm)
3.27 in.
(83 mm)
6.30 in.
(160 mm)
2.78 in.
(70.5 mm)
2.37 in.
(60.2 mm)1.67 in.
(42.5 mm)
3.27 in.
(83 mm)
6.30 in.
(160 mm)
2.19 in.
(55.5 mm)
3.15 in.
(80 mm)
2.19 in.
(55.5 mm) 1.67 in.
(42.5 mm)
3.27 in.
(83 mm)
3.15 in.
(80 mm)
2.19 in.
(55.5 mm) 1.67 in.
(42.5 mm)
3.27 in.
(83 mm)
2.28 in.
(58 mm)
Publication 1492-TD008A-EN-P - March 2001
160 Digital/Analog Programmable Controller Wiring Systems
AIFM DimensionsCat. No. 1492-AIFM4-3
Cat. Nos. 1492-AIFM6S-3, 1492-AIFM6TC-3
Cat. Nos. 1492-AIFM4C-F-5, 1492-AIFM4I-F-5
Cat. No. 1492-AIFM8-3
3.27 in.(83 mm)
2.74 in.(69.5 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
2.36 in.(60 mm)
3.15 in.(80 mm)
3.27 in.(83 mm)
2.74 in.(69.5 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 in.)
3.15 in.(80 mm)
3.27 in.(83 mm)
2.74 in.(69.5 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 in.)
3.27 in.(83 mm)
2.74 in.(69.5 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
4.33 in.(110 mm)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 161
AIFM Dimensions, Continued Cat. Nos. 1492-AIFM8-F-5, 1492-AIFM16-F-3, 1492-AIFMQS, 1492-AIFMPI
Cat. No. 1492-AIFM16-F-5
3.27 in.(83 mm)
2.74 in.(69.5 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
4.72 in.(120 mm)
3.27 in.(83 mm)
2.74 in.(69.5 mm)
2.19 in.(55.5 mm)
1.67 in.(42.5 mm)
8.27 in.(210 mm)
Publication 1492-TD008A-EN-P - March 2001
162 Digital/Analog Programmable Controller Wiring Systems
Marking Systems Pre-Printed and Blank Adhesive Label Cards
All Bulletin 1492 IFMs, XIFMs, and AIFMs come with an adhesive label card. The label card provides the field-side connection descriptions for the programmable controller I/O module. The label strips basically copy the wiring descriptions from the I/O module in the chassis down to the Interface Module terminals on the DIN Rail.The label cards list all of the compatible I/O modules and their respective wiring descriptions. Depending on the I/O module that is used, the label strip(s) are simply peeled from the label card and applied to the field-side terminals on the Interface Module. Refer to the respective I/O Module Product Data for actual wiring connections and recommendations.Labels are provided in the octal and decimal numbering systems for Bulletin 1746 I/O modules. Labels for Bulletin 1771 I/O modules are supplied in the octal numbering system, like the I/O modules themselves. Labels for Bulletin 1756 and 1769 I/O modules are supplied in the decimal numbering system, like the I/O modules. Interface Modules with LEDs or fuse clips come with the LEDs or fuse clips/blown fuse indicators numbered in decimal. LED and fuse labels are also provided in octal for use with Bulletin 1771 I/O modules. The LED or fuse conversion label(s) are placed directly on the circuit board of the Interface Module. For extra terminal modules, pre-printed labels are provided to identify the power bus(ses) or commoned terminals (middle and/or lower rows of terminals) on the Interface Module. For each I/O module, corresponding labels with L1, L2, COM, or +V are provided. The labels indicate isolated power busses or grouped commons with a different letter or number. For example, L1-A, L1-B, L1-C or COM1, COM2, COM3, etc.In addition, if generic numbering of the field-side terminals is desired, numeric labels are provided. Examples: 120, 140, and evens and odds. For write-on identification, the label cards contain blank label strips (for field-side terminals) and rectangular boxes (for the large group marking area on each IFM, XIFM, or AIFM).All of the available labels are shown on pages 163198. This information is helpful for determining field-side wiring layouts prior to installation.An example of how the labels are applied is shown below:
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 163
Marking Systems, Continued
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20F, -IFM20D24, and -IFM20D120
Publication 1492-TD008A-EN-P - March 2001
164 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20F, -IFM20D24, and -IFM20D120
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 165
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM40F and -IFM40D24
166 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20D120-2, -IFM20F-F-2, -IFM20F-F24-2, -IFM20F-F120-2, and -IFM20D240-2
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 167
Marking Systems, Continued
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20D120-2, -IFM20F-F-2, -IFM20F-F24-2, -IFM20F-F120-2, and -IFM20D240-2
Publication 1492-TD008A-EN-P - March 2001
168 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20F-F-2, and -IFM20F-F24-2
MODULE LABEL LEVELI/O CAT. NO.
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
COM2
COM2
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 L2 L21769-IA16
1769-IQ16 SINK
1769-IQ16 SOURCE
45006-237-01 (A)
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
L11
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
OUT1
OUT3
OUT5
OUT9
OUT11
OUT13
OUT15
VDC2
VDC2
VDC1
VDC1
+VDC
L2 L2
COM1
COM1
OUT0
L11
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
L12
L12
1769-OA8. -OW8 (AC)
1769-OW8 (DC)
1769-OB16
1769-OV16
NUMERIC
LED LABEL
FUSE LABEL
3 4 5 61 2 7 8 9 10 11 12 13 14 15 16 17 18 19 20
25 26 27 28 29 30 32 33 34 35 36 37 38 39 40
5 7 9 111 3 13 15 17 19 21 23 25 27 29 33 35 37 39
6 8 10 122 4 14 16 18 20 22 24 26 28 30 32 34 36 38
00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17
L1 L1
+VDC1
+VDC2
COM1
COM2
L21
L22
+VDC1
OUT0
+VDC1
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
+VDC2
+VDC2
COM1
COM2
OUT7
OUT0+VDC OUT
2OUT
4OUT
6OUT
8OUT10
OUT12
OUT14 COM COM
COM COM
OUT1
OUT3
OUT5
OUT9
OUT11
OUT13
OUT15+VDC OUT
7OUT
0+VDC OUT2
OUT4
OUT6
OUT8
OUT10
OUT12
OUT14 COM COM
+VDC +VDC
01 02 03 0400 05 06 07 10 11 12 13 14 15 16 17
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
40
31
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 169
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM20F-F240-2, -IFM20F-FS120-4, and -IFM20F-FS240-4
MODULE LABELI/O CATATA . NO.
45006-110-01 (E)
LEVEL
Upper
Lower
Lower
Upper
Upper
Upper
Lower
Lower
Lower
Lower
Upper
Lower
Upper
Upper
Upper
Upper
Lower
Lower
L20
L21
L22
L23
L24
L25
L26
L27
L10
L11
L12
L13
L14
L15
L16
L17
COM0
COM1
COM2
COM3
COM4
COM5
COM6
COM7 +V0 +V1 +V2 +V3 +V4 +V5 +V6 +V7
L20
L20
L20
L20
L21
L21
L21
L21
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
L20
L21
L22
L23
L21
L21
L21
L21
L21
L21
L24
L25
L26
L27
L22
L22
L22
L22
L22
L22
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
COM0
COM1
COM2
COM3
COM4
COM5
COM6
COM7
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
L20
L20
L20
L20
L21
L21
L21
L21
L10
L10
L10
L10
L11
L11
L11
L11
+VDC2
COM2
COM2
COM2
+VDC2
COM2
COM2
COM2
1 2 3 4 5 6 7 8
1746-OW16 (DC)
1756-OA8, -OA8D, -OA8E TC-ODC081, TC-ODX081
1756-OA16TC-ODA161
1746-OX8 (AC)
NUMERIC
1746-OX8 (DC)
1746-OA16,1746-OW16 (AC)
1771-OMD
LED LABEL
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
L11
L11
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
L12
L12
L11
L11
OUT00
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17
L12
L12
L21
L22
L10
L20
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
L11
L21
L20
L21
Upper1769-OA8,-OW8 (AC)
L11
L12
L11
COM1
COM1
COM1
COM1
COM1
COM1
+VDC1
+VDC1
L12
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
L2 L2
+V1 +V1 OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15 +V2 +V2
+V1 +V1 OUT00
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17 +V2 +V2
L1 L1 OUT00
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17 L1 L2
COM1
COM2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
21 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
Upper1769-OW8 (DC)
1769-OW8I (AC)
1769-OW8I (DC)
Publication 1492-TD008A-EN-P - March 2001
170 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. No. 1492-IFM20D24A-2, -IFM20D120A-2, and -IFM20D240A-2
4500
6-08
6-01
(D)
LED
LABE
L
34
56
12
78
910
1112
1314
1516
0010
1112
1314
1516
17
12
34
56
78
910
1112
1314
1516
1718
1920
3233
3435
3637
3839
40
2325
2729
3133
3537
39
224
2628
3032
3436
3840
NUM
ERIC
0001
0203
0405
0607
1011
1213
1415
1617
FUSE
LAB
EL
0102
0304
0005
0607
1011
1213
1415
1617
23
45
16
78
910
1112
1314
1516
MOD
ULE
LABE
LI/O
CATATA
. NO.
ININ
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
L2L2
IN 00IN
ININ 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
L2L2
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
COM
COM
1746
-IA16
, IM
16,
IN16
(AC)
1746
-IB16
,IN
16 (D
C),
ITB1
6
1746
-IV16
, ITV
16
IN 00IN 01
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
COM
COM
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
+V+V
IN 00IN 01
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
+V+V L2
IN 0IN 1
L2 0L2 0
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
L2 1L2 1
1769
-IM12
IN 1 0
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN
L2IN 01
00IN 02
IN 03IN 04
IN 05IN 06
IN 07IN 10
IN 11IN 12
IN 13IN 14
IN 15IN 16
IN 17IN
L1
L217
71-IM
D01
00IN 02
IN 03IN 04
IN 05IN 06
IN 07IN 10
IN 11IN 12
IN 13IN 14
IN 15IN 16
IN 17IN
1756
-IA16
TC-ID
A161
IN 0IN 1
GND 0
GND 0
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
GND 1
GND 1
IN 0IN 1
L1 0IN 2
IN 3L2 0
L2 0L2 0
L2 0L2 1
L2 1L2 1
L2 1IN 4
IN 5IN 6
IN 7L1 1
L2 1
1756
-IB16
TC-ID
D161
1756
-IA8D
TC-ID
X081
LEVE
L
Upp
er
Upp
er
Low
er
Upp
er
Upp
er
Low
er
Upp
er
Upp
er
Low
er
Upp
er
Low
er
Low
er
Upp
er
Low
er
Low
er
Upp
er
Low
er
Upp
er
Low
er
Upp
er
Upp
er
Upp
er
Low
er
CO
M
L1 L1
IN 0IN 1
L2 0L2 0
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
L2 1L2
L2L2
L2L21
1756
-IN16
L1
+D
C
+V
L1L1 L1 L1
1769
-IA16
Upp
er
Low
erL1
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
COM
COM
COM
COM
1769
-IQ16
SIN
KU
pper
Low
er+
VD
C+
VD
C
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
+VDC
+VDC
+VDC
++VDC
++VDC
+17
69-IQ
16SO
URCE
Upp
er
Low
erC
OM
CO
M
COM
0100
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
IN+V
COM
1771
-IBD,
ICD
0100
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
IN
Upp
er
Low
er
Upp
er
Low
er+
V+V
1771
-IND
(DC)
1771
-IAD,
IND
(AC)
L2
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 171
Marking Systems, Continued
Adhesive Label Card for Cat. No. 1492-IFM20F-3 (Series B)
Publication 1492-TD008A-EN-P - March 2001
172 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM40F-2, -IFM40D24-2, -IFM40D24A-2, -IFM40D120-2, -IFM40D120A-2, -IFM40F-F-2, -IFM40F-F24-2, and -IFM40F-F120-2
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 173
Marking Systems, Continued
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM40F-2, -IFM40D24-2, -IFM40D24A-2, -IFM40D120-2, -IFM40D120A-2, -IFM40F-F-2, -IFM40F-F24-2, and -IFM40F-F120-2
GROUP 3 INPUTS
Publication 1492-TD008A-EN-P - March 2001
174 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20FN, -IFM20D24N, and -IFM20D120N
MODULE LABELI/O CAT. NO. LEVEL
1746-IA16, IN16 (AC) Upper
Lower
Upper
Upper
Lower
Lower
Upper
Lower
Upper
1746-IB16, IC16,IH16, IN16 (DC), ITB16
1746-IG16
1746-OB16, OB16E,OBP16, OG16,OV16, OVP16
1746-IV16, ITV16
1746-OW16 (DC)
1746-OX8 (AC)
1746-OX8 (DC)
1746-OA16, OW16 (AC)1771-OAD, OND
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 L2
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7 L2
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17 L2
IN00
IN01
IN02
IN03
IN04
IN05
IN06
IN07 L2
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 COM
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7 COM
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17 COM
IN00
IN01
IN02
IN03
IN04
IN05
IN06
IN07 COM
+V IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 COM
+V IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7 COM
+V IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17 COM
L1 OUT00
L1 OUT0
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07 L1
+V OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15 COM
+V IN00
L1 OUT8
IN01
IN02
IN03
IN04
IN05
IN06
IN07 COM
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 +V
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7 +V
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17 +V
IN00
IN01
IN02
IN03
IN04
IN05
IN06
IN07 +V
+V OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7 +V
+V OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17 COM
+V OUT00
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07 +V
OUT4
L14
OUT5
L15
OUT6
L16
OUT7
L17
L11
OUT1
L10
OUT0
L12
OUT2
L13
OUT3
OUT4 +V4 OUT
5 +V5 OUT6 +V6 OUT
7 +V7
+V1 OUT1+V0 OUT
0 +V2 OUT2 +V3 OUT
3
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15 L2
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7 L1
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17 L2
Lower
Upper
Lower
Upper+V OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15 COM
+V OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7 COM
+V OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17 COM
+V OUT00
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07 COM
Lower
Lower
Upper
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Lower
Upper
Upper
Lower
Upper
Lower
Upper
Lower
L1 OUT10
L21
L21
L10
L21
L21
IN4
IN5
IN6
IN7
L21
IN0
IN1
IN2
IN3
L20
L20
L20
L20
L11
1756-IA8DTC-IDX081
44006-274-02 (D)
LED LABEL
NUMERIC
1771-IAD (AC),IND (AC)
1771-IAD (DC),IND (DC)
1771-IGD
1771-OBD, OGD
1771-IBD, ICD
+V IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17 COM
+V IN00
IN01
IN02
IN03
IN04
IN05
IN06
IN07 +V
+V OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
OUT17 COM
+V OUT00
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT 07 +V
1 2 3 4 5 6 7 8 9 10
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
11 12 13 14 15 16 17 18 19 20
IN10
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17 L2
IN11
IN12
IN13
IN14
IN15
IN16
IN17 COM
IN01
IN02+V IN
00IN03
IN04
IN05
IN06
IN07
IN01
IN02L1 IN
00IN03
IN04
IN05
IN06
IN07
IN01
IN02
IN00
IN03
IN04
IN05
IN06
IN07
10 11 12 13 14 15 16 17
00 01 02 03 04 05 06 07
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Lower
Upper
Lower
Upper
Lower
Upper
IN11
IN14
IN15
IN12
IN13
IN16
IN17 COMIN
10
IN9
IN10
L20
IN8
IN11
IN12
IN13
IN14
IN15
L21
IN1
IN2
L20
IN0
IN3
IN4
IN5
IN6
IN7
L21
IN9
IN10
GND0
IN8
IN11
IN12
IN13
IN14
IN15
GND1
IN1
IN2
GND0
IN0
IN3
IN4
IN5
IN6
IN7
GND1
1756-IA16, IN16TC-IDA161
L11
L11
L20
L11
L11
OUT4
OUT5
OUT6
OUT7
L11
OUT1
OUT2
OUT0
OUT3
L10
L10
L10
L10
L21
1756-OA8D, OA8ETC-ODX081
1756-IB16, IC16TC-IDD161TC-IDE161
L11
L11
OUT0
L11
L11
OUT4
OUT5
OUT6
OUT7
L11
OUT2
OUT3
L10
OUT1
L10
L10
L10
L10
1756-OA8, ON8TC-ODC081
OUT9
OUT10
L20
OUT8
OUT11
OUT12
OUT13
OUT14
OUT15
L21
OUT1
OUT2
L10
OUT0
OUT3
OUT4
OUT5
OUT6
OUT7
L11
1756-OA16 TC-ODA161
1756-OB16ETC-ODD161
+DC1
+DC1
OUT0
+DC1
+DC1
OUT4
OUT5
OUT6
OUT7
RTN1
OUT9
OUT10
RTN0
OUT8
OUT11
OUT12
OUT13
OUT14
OUT15
RTN1
OUT2
OUT3
+DC0
OUT1
RTN0
+DC0
+DC0
+DC0
RTN0
RTN1
1756-OB8, OC8TC-ODD081TC-ODE081
OUT1
OUT2
+DC0
OUT0
OUT3
OUT4
OUT5
OUT6
OUT7
+DC1
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 175
Marking Systems, Continued
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20FN, -IFM20D24N, and -IFM20D120N
MODULE LABELI/O CAT. NO.
45006-236-01 (C)
LED LABEL
LEVEL
NUMERIC
1769-IA16 Upper
Lower
Upper
Upper
Lower
Lower
Upper
Lower
Upper
1769-OA8 (AC),-OW8
L2
L2
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 L2
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7 L2
1769-IQ16 SINK
1769-IQ16 SOURCE
COM1
COM1
+VDC1
+VDC1
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
COM2
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
COM2
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
+VDC2
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
+VDC2
OUT4
OUT5
OUT6
OUT7
L12
OUT0
OUT1
OUT2
OUT3
L11
L12
L11
1769-OW8 (DC)
1769-OB16, -OV16
OUT4
OUT5
OUT6
OUT7
+VDC2
OUT0
OUT1
OUT2
OUT3
+VDC1
+VDC2
+VDC1
+VDC IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15 COM
+VDC IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7 COM
1 2 3 4 5 6 7 8 9 10
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
11 12 13 14 15 16 17 18 19 20
10 11 12 13 14 15 16 17
00 01 02 03 04 05 06 07
Lower
Upper
Lower
1769-IA8I IN4
L24
IN5
L25
IN6
L26
IN7
L27
IN0
L20
IN1
L21
IN2
L22
IN3
L23
Upper
Lower
Publication 1492-TD008A-EN-P - March 2001
176 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM20DS24-4 and -IFM20DS120-4
1 2 3 4 5 6 7 8
MODULE LABEL LEVEL
UPPER
DC0
DC1
DC2
DC3
DC4
DC5
DC6
DC7
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
COM0
COM0
COM1
COM1
COM2
COM2
COM3
COM3
COM4
COM4
COM5
COM5
COM6
COM6
COM7
COM7
COM0
COM0
COM0
COM0
COM0
COM0
COM0
COM0
COM1
COM1
COM1
COM1
COM1
COM1
COM1
COM1
OUT7
COM1
COM1
COM1
COM1
COM1
COM1
COM1
COM1
COM2
COM2
COM2
COM2
COM2
COM2
COM2
COM2
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7L1 L1 L1 L1 L1 L1 L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT
0 0 0 0 1 1 1 1 0 1 2 3 4 5 6 7L1 L1 L1 L1 L1 L1 L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT
0 0 0 0 1 1 1 1 0 1 2 3 4 5 6 7L1 L1
0 0L1 L1
0 0RTN RTN
0 0RTN RTN
1 1RTN RTN
1 1RTN
2L1
RTN
L1 L1 L1 L1 L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT1
L1
0 0 0 0 1 1 1 1 0 1 2 3 4 5 6 7+DC +DC +DC +DC +DC +DC +DC +DC OUT OUT OUT OUT OUT OUT OUT OUT
L20
L20
L21
L21
L22
L22
L23
L23
L24
L24
L25
L25
L26
L26
L27
L2 7
L20
L20
L20
L20
L20
L20
L20
L20
L21
L21
L21
L21
L21
L21
L21
L21
L21
L21
L21
L21
L21
L21
L21
L22
L22
L22
L22
L22
L22
L22
L2 1
L2 2
OUT7
L20
L20
ZCL200
L20
L20
L20
L20
L20
L20
L21
L21
L21
L21
L21
L21
L21
L2 1
I/O CAT. NO.
1746-OX8 (AC)
1746-OX8 (DC)
1756-OA8D,1756-OA8E,TC-ODX081
1756-OB8, -OC8,TC-ODD081,TC-ODE081
1756-OA8,1756-ON8,TC-ODC081
LOWER
UPPER
LOWER
UPPER
LOWER
UPPER
LOWER
UPPER
LOWER
1L1
1L1
2L1
1769-OA8 (AC),-OW8
UPPER
LOWER
1+VDC
1+VDC
2+VDC
2+VDC
1769-OW8 (DC) UPPER
LOWER
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
NUMERIC
LED
45006-056-01 (E)
ZCL211
1L1
1769-OW8I (AC)
1769-OW8I (DC)
0 1 2 3 4 5 6OUT OUT OUT OUT OUT OUT OUT
0 1 2 3 4 5 6OUT OUT OUT OUT OUT OUT OUT
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 177
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM20F-FS-2, -IFM20F-FS24-2, and -IFM20F-FS120-2
MODULE LABELI/0 CAT. NO.
1746-OX8 (AC)
1746-OX8 (DC)
1769-OA8 (AC),OW8
1756-OA8D1756-OA8ETC-ODX081
LED LABEL
45006-022-01 (D)
NUMERIC
1756-OB81756-OC8TC-ODD081TC-ODE081
LEVEL
UPPER0 1 2 3 4 5 6 7
0L1
0L2
1L1 2L1 3L1 4L1 5L1 6L1 7L1
R0 0 1 2 3 4 5 6 7
+V0R0 +V0 +V0 +V0 +V1 +V1 +V1 +V1
R1
R1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7
11 12 13 14 15 16 17 18 19 20
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 17 20
LOWER
UPPER0 1 2 3 4 5 6 7
+V0 +V1 +V2 +V3 +V4 +V5 +V6 +V7 LOWER
UPPER
LOWER
UPPER
LOWER
0 1 2 3 4 5 6 7
0L1 0L1 0L1 0L1 1L1 1L1 1L1 1L1 1L2
L11
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
L12
L11
L12
0L1
0L1 0L1 0L1 0L1 1L1 1L1 1L1 1L1
1L1 UPPER0 1 2 3 4 5 6 7
LOWER
UPPER
LOWER
UPPER
LOWER
1769-OW8 (DC) +VDC1
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
+VDC2
+VDC1
+VDC2
UPPER
LOWER
8
1756-OA81756-ON8TC-ODC081
1769-OW8I (AC)
1769-OW8I (DC)
Publication 1492-TD008A-EN-P - March 2001
178 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM20F-FS24A-4 and -IFM20F-FS120A-4
1 2 3 4 5 6 7 8
MODULE LABEL LEVEL
UPPERL20
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
L10
0 1 2 3 4 5 6 7
L21
L10F
L10F
L10F
L10F
L11F
L11F
L11F
L11F
L11
0F 1F 2F 3F 4F 5F 6F 7F
COM IN IN IN IN IN IN IN IN +DC
COM +DC +DC +DC +DC
I/O CAT. NO.1756-IA8DTC-IDX081
1771-IB, -IH, -IT
LED
45006-120-01 (B)
LOWER
UPPER
LOWER
1 3 4 5 6 7 8 9 10 11 12 13 14
21 22 23 24 25 26 27 28
5 7 9 13 15 17 19 21 23 25 27
2 4 6 8 12 14 16 18 20 22 24 26 28
NUMERIC
0 1 2 3 4 5 6 7
OF 1F 2F 3F 4F 5F 6F 7F
L2 IN IN IN IN IN IN IN IN L1
L2 L1 L1 L1 L1 L1 L1 L1 L1 L1
1771-IA, -IA2,-IN (AC) UPPER
LOWER
1771-IA, IA2,-IN (DC)
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 179
Marking Systems, Continued
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20D24-3, -IFM40F-3, and -IFM40D24-3
Publication 1492-TD008A-EN-P - March 2001
180 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20D24-3, -IFM40F-3, and -IFM40D24-3
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 181
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. Nos.1492-IFM20F-F24A-2 and -IFM20F-F120A-2
MOD
ULE
LABE
LI/O
CATATA
. NO.
IN16
(DC)
, ITB
16
1746
-IA16
,IN
16 (A
C)
1756
-IB16
TC-ID
D161
1769
-IQ16
SINK
ING
1756
-IA16
, IN1
6TC
-IDA1
61
1771
-IAD
(AC)
IND
(AC)
LEVE
L
Uppe
r
U ppe
r
Low
er
Low
er
Uppe
r
L ow
er
Uppe
r
L ow
er
Uppe
r
L ow
er
Low
er
Low
er
Uppe
r
U ppe
r
L ow
er
Uppe
r
L ow
er
Uppe
r
Uppe
r
L ow
er
Low
er
Uppe
r
1771
-IBD,
ICD
1771
-IAD
(DC)
IND
(DC)
ININ
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
L1 00F
L1 01F
L1 02F
L1 03F
L1 04F
L1 05F
L1 06F
L1 07F
L1 10F
L1 119F
L1 12F
L1 13F
L1 14F
L1 15F
L1 16F
L1 17F
IN 00IN 01
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
+V 00F
+V 01F
+V 02F
+V 03F
+V 04F
+V 05F
+V 06F
+V 07F
+V 10F
+V 119F
+V 12F
+V 13F
+V 14F
+V 15F
+V 16F
+V 17F
6F7F
8F9F
13F
14F
15F
ININ
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
L1 5FL1 6F
L1 7FL1 8F
L1 9FL1
L1L1 12
FL1 13
FL1 14
FL1 15
F
IN 00IN 01
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
IN 00IN 01
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
+V 00F
+V 01F
+V 02F
+V 03F
+V 04F
+V 05F
+V 06F
+V 07F
+V 10F
+V 11F
+V 12F
+V 13F
+V 14F
+V 15F
+V 16F
+V 17F
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
COM
COM
IN 00IN 01
IN 02IN 03
IN 04IN 05
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
+V 0F+V 1F
+V 2F+V 3F
+V-A
+V 4F+V 5F
+V 6F+V 7F
+V 8F+V 9F
+V 10F
+V 11F
+V 12F
+V 13F
+V 14F
+V 15F
+V-B
+V 00F
+V 01F
+V 02F
+V 03F
+V-A
+V-A
+V-A
+V-A
GND 0
GND
+V
+V 04F
+V 05F
+V 06F
+V 07F
+V 10F
+V 11F
+V 12F
+V 13F
+V 14F
+V 15F
+V 16F
+V 17F
COM
+VCO
M
+V-B
+V-B
+V-B
+V-A
+V-A
+V-B
L1L2
+V-B
Low
er
Uppe
r17
69-IA
16IN
ININ 2
IN 3IN 4
IN 5IN 6
IN 7IN 8
IN 9IN 10
IN 11IN 12
IN 13IN 14
IN 15L1 0F
L1 5FL1 6F
L1 7FL1 8F
L1 9FL1
L1L1 12
FL1 13
FL1 14
FL1 15
FL1
L1L1
L1
+V-A
+V-A
+V-B
+V-B
GND 1
GND 1
+DC A
A
L2 0L2 0
+DC B
+DC B
L2 1L2 1
L2L2
L2L2
Low
er
Uppe
r17
69-O
V16
OUT
OUT
OUT
OUT
OUT
OUT 5
OUT 6
OUT 7
OUT 8
OUT 9
OUT
10OU
T11
OUT
12OU
T13
OUT
14OU
T15
+V 0F+V 6F
+V 7F+V 8F
+V 9F+V
+V+V 12
F+V 13
F+V 14
F+V 15
F+V
DC+V
DC+V
DC+V
DC
+VDC
+VDC
COM
COM
IN 0IN 1
IN 2IN 3
IN 4IN 5
IN 6IN 7
IN 8IN 9
IN 10IN 11
IN 12IN 13
IN 14IN 15
L2L2
ININ
ININ
IN 06IN 07
IN 10IN 11
IN 12IN 13
IN 14IN 15
IN 16IN 17
L2L2
L1-A
L1L1 6F
L1 7FL1 8F
L1L1
L1L1
L1 13F
L1 14F
L1
L1-B
L1-A
L1L1
L1L1
L1L1
L1L1 14
FL1 15
FL1 16
FL1 17
F
L1-B
L1-A
L1-A
L1-B
L1-B
L1-A
L1-A
L1-B
OUT
OUT
OUT
OUT
OUT
OUT 5
OUT 6
OUT 7
OUT
OUT
OUT
OUT
11OU
T12
OUT
13OU
T14
OUT
15
0607
1014
1516
+V 6F+V 7F
+V 8F+V
+V+V
+V+V 13
F+V 14
F+V
+V+V
+V+V
+V+V 14
F+V 15
F+V 16
F+V 17
F
1746
-OV1
6, O
VP16
4500
6-10
0-01
(C)
LED
LABE
L
12
34
56
78
910
1112
1314
1516
1718
1920
NUM
ERIC
12
34
56
78
1316
910
1112
1415
3336
3132
3435
3738
4039
17
925
3121
2327
2933
3539
37
26
826
3222
2428
3034
3640
38
Publication 1492-TD008A-EN-P - March 2001
182 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM40DS24-4, -IFM40DS24A-4, -IFM40DS120-4, -IFM40DS120A-4, and -IFM40DS240A-4
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 183
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS-2, -IFM40F-FS24-2, and -IFM40F-FS120-2
10 11 12 13 17161514
9 10 11 12 16151413
1 2 3 4 8765
00 01 02 03 07060504
Publication 1492-TD008A-EN-P - March 2001
184 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS24-4 and -IFM40F-FS240-4
1
00
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
01 02 03 04 05 06 07 10 11 12 13 14 15 16 17
MODULE LABEL LEVEL
UPPERL20
L21 2 4
L25
L26
L27
L28
L29
L210
L214
L215
OUT0
OUT1
OUT2 3 4 6 7
OUT8
OUT9
OUT10
OUT11
0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 0NC 0NO 1NC 1NO 2NC 2NO 3NC 3NO 4NC 4NO 5NC 5NO
12OUT15
L20 1 2 4 5
L26
L27
L28
L29 10 14
L215
L10
L11 2 3 4 6 7 8
L19
L110 11 12 15
0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 2 3 3 4 4 5 5 6 6 7
L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT6NC
OUT6NO
OUT7NC
OUT7NO
L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1
0 0 1 2 2 3 3 4 4 5 5 6 7 7 0NC ONO 1NC 4NC 4NO 5NC 5NO 7NOCOM OUT OUT OUT
0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 2 3 3 4 4 5 5 6 6 7COM +DC +DC +DC
I/O CAT. NO.1756-OA16I1756-OW16I (AC)TC-ODK161TC-ORC161 (AC)1756-OB8EI
1756-OB16DTC-ODX161
1756-OX8I (AC)TC-ORC081 (AC)
1756-OX8I (DC)TC-ORC081 (DC)
LED
45006-047-02 (D )
LOWER
UPPER
LOWER
UPPER
LOWER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68
NUMERIC
8 1 9 10
0 1 2 4 5 6 7 8 9 10 14 15 0 1 2 3 4 6 7 8 9 10 11 12 15
COM COM COM COM OUT OUT OUT OUT OUT OUT OUT OUT
COM COM COM COM +DC +DC +DC +DC +DC +DC +DC +DC
1756-OW16I (DC),-OB16ITC-ORC161 (DC),TC-ODJ161
UPPER
LOWER
0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 2 3 3 4 4 5 5RTN RTN OUT OUT OUT OUT
6 6 7
0 0 1 2 2 3 3 4 4 5 5 6 7 7 0 0 1 1 3 4 4 5 5RTN RTN RTN RTN RTN RTN +DC RTN RTN +DC RTN
6RTN
0 1 0 1 9 10GND GND GND GND GND GND OUT OUT OUT OUT OUT OUT OUT
0 1 0 0 1 1GND GND GND GND GND GND +DC +DC +DC +DC +DC +DC +DC GND
UPPER
LOWER
UPPER
LOWER
00 06 07 10 11 17 00 01 02 10 11 12 13COM OUT OUT OUT
00 06 07 10 11 17 00 01 02 10 11 12 13COM COM COM COM +V +V +V +V +V +V +V
1771-OQ16 UPPER
LOWER
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 185
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS120-4, -IFM40F-FS24A-4, and -IFM40F-FS120A-4
186
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-XIM2024-8R, -XIM20120-8R, and -XIM4024-8R
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 187
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-XIM24-8R and -XIM120-8R
Publication 1492-TD008A-EN-P - March 2001
188 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-XIMF-F24-2, -XIMF-F120-2, and -XIMF-2
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 189
Marking Systems, Continued
Adhesive Label Card for Cat. No. 1492-XIM4024-16R
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001
190 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-AIFM4I-F-5 and -AIFM4C-F-5
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 191
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. No. 1492-AIFM4-3
MODULE LABEL LEVELUpper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Lower
Upper
Lower
I/O CAT. NO.1746-NI4
1746-NIO4I,-NIO4V, -FIO4I,-FIO4V
1746-NO4I, -NO4V
1769-IF4
1756-OF4TC-OAV041
45006-034-01 (D)
NUMERIC
2+ 2- C SH 3+ 3- C SH
0+ 0- C SH 1+ 1- C SH
0+ 0- C SH 1+ 1- C SH
2 C +V SH 3 C -V SH
0 C +V SH 1 C -V SH
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
1 3 5 7 9 11 13 15
2 4 6 8 10 12 14 16
2 C SH 3 C SH
0 C SH 1 C SH
2+ 2- SH 3+ 3- SH
Upper2 RTN SH 3 RTN SH
0 RTN SH 1 RTN SH
0+ 0- SH 1+ 1- SH
O/0 C SH O/1 C SH
Upper
Lower
1769-IF4 2+ SH 3+ SH
0+ SH 1+ SH
Lower
DIFF. VOLTAGEDIFF. CURRENT
SNG. END. VLTG.SNG. END. CUR.
1769-OF2SNG. END. VLTG.SNG. END. CUR.
Upper
Lower
1771-OFE 3+ 3- SH 4+ 4- SH
1+ 1- SH 2+ 2- SH
0+ COM SH 1+ COM SH
COM
Publication 1492-TD008A-EN-P - March 2001
192 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. Nos. 1492-AIFM6S-3 and -AIFM6TC-3
Digital/Analog Programmable Controller Wiring Systems 193
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Part 1 of Adhesive Label Card for Cat. No. 1492-AIFM8-3
MODULE LABELI/O CAT. NO.
1756-IF8TC-IAH081
1756-IF16TC-IAH161
1756-OF8TC-OAV081
LEVEL
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Upper
Lower
Upper
Lower
Upper
Lower
Lower
Upper
SINGLE ENDED VOLTAGE INPUTS
1746-NI8
1771-IFESINGLE ENDED
0 1 2 3 4 5 6 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0 RTN 1 2 RTN 3 4 RTN 5 6 RTN 7
RTN
RTN
0 RTN 1 RTN 2 RTN 3 RTN 4 RTN 5 RTN 6 RTN 7 RTN
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
OUT0 RTN OUT
1 RTN OUT2 RTN OUT
3 RTN OUT4 RTN OUT
5 RTN OUT6 RTN OUT
7 RTN
Upper
Lower
Upper
Lower
0+ 0- 1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7-
SHIELD MODULE COM
SHIELD RTN
SINGLE ENDED CURRENT INPUTS
SHIELD RTN + I RTN
DIFFERENTIAL VOLTAGE INPUTS
SHIELD RTN
0 1 2 3 4 5 6 7DIFFERENTIAL CURRENT INPUTS
SINGLE ENDED VOLTAGE INPUTS
SINGLE ENDED CURRENT INPUTS
DIFFERENTIAL VOLTAGE INPUTS
DIFFERENTIAL CURRENT INPUTS
SHIELD RTN
SHIELD RTN
SHIELD RTN + I RTN
SHIELD RTN
SHIELD RTN
SHIELD RTN
COMSHIELD
LowerSHIELD RTN
1746-NI16V Upper
Lower
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
COMSHIELD
COMSHIELD
Upper
Lower
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 151746-NI16I SINGLE ENDED CURRENT INPUTS
SINGLE ENDED VOLTAGE INPUTS
Publication 1492-TD008A-EN-P - March 2001
194 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Part 2 of Adhesive Label Card for Cat. No. 1492-AIFM8-3
45006-019-01 (D)
1771-IL
NUMERIC
1771-IFEDIFFERENTIAL
Upper
Upper
Lower
Lower
Upper
Lower
Upper
Lower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7- 8+ 8-
1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7- 8+ 8-
MODULE COM
COM
SHIELD
SHIELD
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 195
Marking Systems, Continued
Adhesive Label Card for Cat. No. 1492-AIFM8-F-5
Publication 1492-TD008A-EN-P - March 2001
196 Digital/Analog Programmable Controller Wiring Systems
Marking Systems, Continued
Adhesive Label Card for Cat. No. 1492-AIFM16-F-3
MODULE LABELI/O CATATA . NO.
1756-IF16TC-IAH161
1771-IFESINGLE ENDED
45006-107-01 (C)
LEVEL
NUMERIC
LED LABEL
Upper
Middle
Middle
Middle
Middle
Middle
1+V 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 COM
SHIELD
SHIELD Lower
Middle
Lower
Upper
+V2F
+V3F
+V4F
+V5F
+V0F
+V1F
+V6F
+V7F
+V8F
+V10F
+V11F
+V12F
+V13F
+V9F
+V14F
+V15F
+V RTN
+V RTN
+V RTN
+V 8 RTN
+V RTN+
V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52
33 3417
1746-NI16I Upper
Middle
Lower
Upper
Middle
Lower
+V2F
+V3F
+V4F
+V5F
+V0F
+V1F
+V6F
+V7F
+V8F
+V10F
+V11F
+V12F
+V13F
+V9F
+V14F
+V15F
1 2 3 4+V 0 5 6 7 9 10 11 128 13 14 15 COM
1746-NI16V +V2F
+V3F
+V4F
+V5F
+V0F
+V1F
+V6F
+V7F
+V8F
+V10F
+V11F
+V12F
+V13F
+V9F
+V14F
+V15F
1 2 3 4+V 0 5 6 7 9 10 11 128 13 14 15 COM
SHIELD
SHIELD
15 15 15 15
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 197
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. No. 1492-AIFM16-F-5
198 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsMarking Systems, Continued
Adhesive Label Card for Cat. No. 1492-AIFMQS
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 199
Marking Systems, Continued
Adhesive Label Card for Cat. No. 1492-AIFMPI
MODULE LABEL LEVEL
UPPER
IN+1
IN-1
IN+2
IN-2
IN+3
IN-3
V0RTN
IN+4
IN-4
IN+5
IN-5
IN+6
IN-6
IN+7
IN-7
V1RTN
SH +V0F
IN+0
IN-0
OUT0
OUT1
RTN0
RTN1
SH +V1F
SH +V2F
SH +V3F
V0+24
SH +V4F
SH +V5F
SH +V6F
SH +V7F
V1+DC
I/O CAT. NO.
1757-PIMTC-MDP081
LOWER
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
NUMERIC
45006-270-01 (A)
Publication 1492-TD008A-EN-P - March 2001
200 Digital/Analog Programmable Controller Wiring Systems
Digital/Analog Programmab le Controller Wiring SystemsAccessories
Replacement Fuse Holders
IFM
The 1492-IFMFH1 fuse holders accommodate either a 5 x 20 mm fuse or the Cat. No. 1492-ISOSW-1 isolation switch plug and reside in the IFM or AIFM under normal operation. All of the fusible Bulletin 1492 IFMs and AIFMs come standard with fuse holders (for the number of fuse holders included, refer to the specifications for each IFM or AIFM). Most IFMs come with 20 fuse holders; 10 fuse holders are included with Cat. Nos.:
40 fuse holders are included with Cat. Nos.:
Replacement fuse holders (Cat. No. 1492-IFMFHI) are available in packages of 20. Cat. No. 1492-IFMFHI fuse holders are not compatible with fusible expandable XIMs.
Cat. No. 1492-IFMFH1Fuse Holder
Cat. No. 1492-ISOSW-1Isolation Switch Plug
Cat. No. 1492-SJM5-10Insulated Side Jumper
• 1492-IFM20F-FS24-2 • 1492-IFM20F-F240-2• 1492-IFM20F-FS120-2 • 1492-IFM20F-FS-2• 1492-IFM20F-F-2 • 1492-IFM20F-FS24A-4• 1492-IFM20F-F24-2 • 1492-IFM20F-FS120-4• 1492-IFM20F-F24A-2 • 1492-IFM20F-FS120A-4• 1492-IFM20F-F120-2 • 1492-IFM20F-FS240-4• 1492-IFM20F-F120A-2
• 1492-IFM40F-F-2 • 1492-IFM40F-FS120-2• 1492-IFM40F-F24-2 • 1492-IFM40F-FS120-4• 1492-IFM40F-F120-2 • 1492-IFM40F-FS240-4• 1492-IFM40F-FS-2 • 1492-IFM40F-FS24A-4• 1492-IFM40F-FS24-2 • 1492-IFM40F-FS120A-4• 1492-IFM40F-FS24-4
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 201
Accessories, Continued Replacement Fuse Holders, Continued
AIFM
The Cat. No. 1492-IFMFH1 fuse holders accommodate a 5 x 20 mm fuse or the Cat. No. 1492-ISOSW-1 isolation switch plug and reside in the AIFM under normal operation. All of the fusible Cat. No. 1492 AIFMs come standard with the fuse holders 10 fuse holders with the Cat. No. 1492-AIFM4C-F-5, -AIFM4I-F-5, and -AIFM8-F-5 modules; 20 fuse holders with the Cat. No. 1492-AIFM16-F-3, and -AIFM16-F-5 modules. Replacement fuse holders are available in packages of 20.
Replacement Relays
The relays in the Relay Master and Relay Expander modules are replaceable. The following replacement relays must be used:
Isolation Switch Plugs
The Cat. No. 1492-ISOSW-1 is an isolation switch or dummy fuse in a 5 x 20 mm fuse form factor. The isolation switch plugs will fit into the Cat. No. 1492-IFMFH1 fuse holders. If fusing is not desired on a fusible IFM or AIFM, the Cat. No. 1492-ISOSW-1 isolatin switch can be used to provide feed-through functionality under normal operation and isolation switch functionality once power has been removed from the circuit. The isolation switch can then be opened for maintenance and troubleshooting. Metering equipment can also be inserted into a two-wire transmitter circuit to measure input loop current. The Cat. No. 1492-ISOSW-1 isolation switch plugs are available in packages of four.
Replacement Relays
XIM Cat. No. Replacement Relay Cat. No.
1492-XIM4024-16R 700-HK36Z24
1492-XIM4024-8R 700-HK36Z24
1492-XIM2024-8R 700-HK36Z24
1492-XIM20120-8R 700-HK36A1
1492-XIM24-8R 700-HK36Z24
1492-XIM120-8R 700-HK36A1
Publication 1492-TD008A-EN-P - March 2001
202 Digital/Analog Programmable Controller Wiring Systems
Accessories, Continued Insulated Side Jumpers
The Cat. No. 1492-SJM5-10 is a 10-pole comb-style insulated side jumper. A side cutter can be used to cut the 10-pole jumper into smaller pole assemblies. The jumper fits the field-side terminal spacings on all of the Bulletin 1492 IFMs and AIFMs. Use of this jumper is a convenient means of connecting unused inputs together on the feed-through. The Cat. No. 1492-SJM5-10 insulated side jumpers are available in packages of 10.
Web Site Information Visit the following web sites for I/O wiring diagrams of the Interface Modules and cables:
• for Bulletin 1746 I/O platform:http://www.ab.com/catalogs/b113/slc/wiring.html
• for Bulletin 1756 I/O platform:http://www.ab.com/catalogs/b113/controllogix/wiring.html
• for Bulletin 1771 I/O platform:http://www.ab.com/catalogs/b113/plc5/wiring.html
• For Bulletin 1769 I/O platform:http://www.ab.com/catalogs/b113/micro1500/wiring.html
To locate the wiring diagram, navigate to one of the above platform sections of the web site and locate the desired product selection table. Select the desired I/O module, Interface Module, and pre-wired cable combination. A letter will appear in the box for all valid combinations. Wiring diagrams can be located by clicking on the underlined letter in the box.
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 203
Quick Reference
Digital IFM Specifications
Digital IFMCat. No.
VoltageRange
Dimensions (L x W x H) (in.)
Indicator Circuit Current (Nominal)
No. Terminals per Device Common
Label CardCat. No.
1492-IFM20F 0…264V AC/DC 4.33 x 3.27 x 2.78 — — 43006-253-011492-IFM20FN 0…132V AC/DC 2.36 x 3.27 x 2.78 — — 44006-274-02, 45006-236-011492-IFM20F-2 0…264V AC/DC 4.33 x 3.27 x 2.78 — 10 43006-253-03, 45006-237-011492-IFM20F-3 0…132V AC/DC 4.33 x 3.27 x 2.78 — 17, 18 45006-077-011492-IFM20D24 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 1 43006-253-011492-IFM20D24N 10…30V AC/DC 2.36 x 3.27 x 2.78 2 mA 1 44006-274-02, 45006-236-011492-IFM20D24-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 10 43006-253-03, 45006-237-011492-IFM20D24A-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 20 45006-086-011492-IFM20DS24-4 10…60V AC/DC 4.33 x 3.27 x 2.78 4.1 mA 2 45006-056-011492-IFM20D24-3 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 18 43006-253-041492-IFM20D120 85…132V AC/DC 4.33 x 3.27 x 2.78 2.5 mA 2 43006-253-011492-IFM20D120N 85…132V AC 2.36 x 3.27 x 2.78 2.5 mA 1 44006-274-02, 45006-236-011492-IFM20D120-2 85…132V AC 4.33 x 3.27 x 2.78 2.5 mA 10 43006-253-03, 45006-237-011492-IFM20D120A-2 85…132V AC 4.33 x 3.27 x 2.78 2.5 mA 20 45006-086-011492-IFM20DS120-4 85…132V AC 4.33 x 3.27 x 2.78 2.6 mA 2 45006-056-011492-IFM20D240-2 204…264V AC 4.33 x 3.27 x 2.78 2.5 mA 10 43006-253-031492-IFM20D240A-2 204…264V AC 4.33 x 3.27 x 2.78 2.5 mA 20 45006-086-011492-IFM20F-F-2 0…132V AC/DC 4.33 x 3.27 x 2.78 — 10 43006-253-03, 45006-237-011492-IFM20F-F24-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 10 43006-253-03, 45006-237-011492-IFM20F-F24A-2 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 10 45006-100-011492-IFM20F-F120-2 85…132V AC 4.33 x 3.27 x 2.78 2.5 mA 10 43006-253-03, 45006-237-011492-IFM20F-F120A-2 85…132V AC/DC 4.33 x 3.27 x 2.78 1.2 mA — 45006-100-011492-IFM20F-F240-2 204…264V AC 4.72 x 3.27 x 2.78 1.2 mA 10 45006-110-011492-IFM20F-FS-2 0…132V AC/DC 2.36 x 3.27 x 2.78 — 1 45006-022-011492-IFM20F-FS24-2 10…30V AC/DC 2.36 x 3.27 x 2.78 2 mA — 45006-022-011492-IFM20F-FS24A-4 10…30V AC/DC 3.15 x 3.27 x 2.78 2 mA — 45006-120-011492-IFM20F-FS120-2 85…132V AC/DC 2.36 x 3.27 x 2.78 2.5 mA 1 45006-022-011492-IFM20F-FS120-4 85…132V AC/DC 4.33 x 3.27 x 2.78 2.5 mA 2 45006-110-011492-IFM20F-FS120A-4 85…132V AC/DC 3.15 x 3.27 x 2.78 2.2 mA — 45006-120-011492-IFM20F-FS240-4 204…264V AC 4.33 x 3.27 x 2.78 2.5 mA 2 45006-110-011492-IFM40F 0…132V AC/DC 4.33 x 3.27 x 2.78 — — 43006-253-021492-IFM40F-2 0…132V AC/DC 8.27 x 3.27 x 2.78 — 10 43006-253-05/061492-IFM40F-3 0…60V AC/DC 8.27 x 3.27 x 2.78 — 18 43006-253-041492-IFM40D24 10…30V AC/DC 4.33 x 3.27 x 2.78 2 mA 1 43006-253-021492-IFM40D24-2 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 10 43006-253-05/061492-IFM40D24A-2 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 10 43006-253-05/061492-IFM40DS24-4 10…60V AC/DC 6.69 x 3.27 x 2.78 4.1 mA 2 45006-054-011492-IFM40DS24A-4 10…30V AC/DC 6.69 x 3.27 x 2.78 4.1 mA 2 45006-054-011492-IFM40D24-3 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 18 43006-253-041492-IFM40D120-2 85…132V AC 8.27 x 3.27 x 2.78 2.5 mA 10 43006-253-05/061492-IFM40D120A-2 85…132V AC 8.27 x 3.27 x 2.78 2.5 mA 10 43006-253-05/061492-IFM40DS120-4 85…132V AC 6.69 x 3.27 x 2.78 2.6 mA 2 45006-054-011492-IFM40DS120A-4 85…132V AC 6.69 x 3.27 x 2.78 2.6 mA 2 45006-054-011492-IFM40DS240A-4 204…264V AC 6.69 x 3.27 x 2.78 2.6 mA 1 45006-054-011492-IFM40F-F-2 0…132V AC/DC 8.27 x 3.27 x 2.78 — 10 43006-253-05/061492-IFM40F-F24-2 10…30V AC/DC 8.27 x 3.27 x 2.78 2 mA 10 43006-253-05/061492-IFM40F-F120-2 85…132V AC 8.27 x 3.27 x 2.78 2.5 mA 10 43006-253-05/061492-IFM40F-FS-2 0…132V AC/DC 4.72 x 3.27 x 2.78 — 1 45006-020-011492-IFM40F-FS24-2 10…30V AC/DC 4.72 x 3.27 x 2.78 2 mA 1 45006-020-011492-IFM40F-FS24-4 10…30V AC/DC 7.09 x 3.27 x 2.78 2 mA 2 45006-047-021492-IFM40F-FS120-2 85…132V AC/DC 4.72 x 3.27 x 2.78 2.5 mA 1 45006-020-011492-IFM40F-FS120-4 85…132V AC/DC 7.09 x 3.27 x 2.78 1.4 mA 2 45006-047-011492-IFM40F-FS240-4 204…264V AC/DC 7.09 x 3.27 x 2.78 1.4 mA 2 45006-047-021492-IFM40F-FS24A-4 10…30V AC/DC 7.09 x 3.27 x 2.78 3.1 mA 1 45006-047-011492-IFM40F-FS120A-4 85…132V AC/DC 7.09 x 3.27 x 2.78 1.4 mA 1 45006-047-01
Publication 1492-TD008A-EN-P - March 2001
204 Digital/Analog Programmable Controller Wiring Systems
Quick Reference, Continued
Analog IFM Specifications
Analog IFMCat. No.
VoltageRange
Dimensions (L x W x H) (in.)
Indicator Circuit Current (Nominal)
No. Terminals per Shield Common
Label CardCat. No.
1492-AIFM4-3 0…132V AC/DC 2.36 x 3.27 x 2.74 — 4 45006-034-011492-AIFM4C-F-5 10…30V DC 3.15 x 3.27 x 2.74 2 mA 4 45006-021-021492-AIFM4I-F-5 10…30V DC 3.15 x 3.27 x 2.74 2 mA 4 45006-021-021492-AIFM6S-3 0…132V AC/DC 3.15 x 3.27 x 2.74 — 6 45006-021-011492-AIFM6TC-3 0…132V AC/DC 3.15 x 3.27 x 2.74 — 6 45006-021-011492-AIFM8-3 0…132V AC/DC 4.33 x 3.27 x 2.74 — 8 45006-019-011492-AIFM8-F-5 10…30V DC 4.72 x 3.27 x 2.74 2 mA 18 44006-274-011492-AIFM16-F-3 10…30V DC 4.72 x 3.27 x 2.74 2 mA 18 45006-107-011492-AIFM16-F-5 10…30V DC 8.27 x 3.27 x 2.74 2 mA 16 45006-018-011492-AIFMQS 10…30V DC 4.72 x 3.27 x 2.74 2 mA 8 45006-018-021492-AIFMPI 0…30V DC 4.72 x 3.27 x 2.74 2 mA 8 45006-270-01
Relay Master/Expandable Interface Module Specifications
Relay Master/Expandable XIM Cat. No.
VoltageRange
Dimensions (L x W x H) (in.)
Indicator Circuit Current (Nominal)
No. Terminals per Device Common
Label CardCat. No.
1492-XIM4024-16R 20…26V DC 9.06 x 3.27 x 2.78 2 mA 16 45006-254-011492-XIM4024-8R 20…26V DC 6.30 x 3.27 x 2.78 2 mA 8 45006-142-011492-XIM2024-8R 20…26V DC 6.30 x 3.27 x 2.78 2 mA 8 45006-142-011492-XIM20120-8R 96…132V AC 6.30 x 3.27 x 2.78 2 mA 8 45006-142-011492-XIM24-8R 20…26V DC 6.30 x 3.27 x 2.78 2 mA 8 45006-143-011492-XIM120-8R 96…132V AC 6.30 x 3.27 x 2.78 2 mA 8 45006-143-011492-XIMF-2 0…132V AC/DC 3.15 x 3.27 x 2.19 2 mA — 45006-144-011492-XIMF-F24-2 10…30V DC 3.15 x 3.27 x 2.28 2 mA 8 45006-144-011492-XIMF-F120-2 85…132V AC 3.15 x 3.27 x 2.28 2 mA 8 45006-144-01
General Specifications
Cat. No. 1492-…UL/CSA Approvals UL Component Recognized, File E113724, Guide No. NRAQ2
CSA Certified, File LR1234, Class 321107, or UL Recognized per Canadian Safety Standards (cUR) (File E113724, Guide No. NRAQ2)
CE Approval —Factory Mutual Approval J.I. 3000590Maximum Peak Transient Voltage 600VMaximum Current (per circuit) 2 A (except relays)Maximum Current (per module) 12 A (except relays)Wire Range (Rated Cross Section) #22…#12 AWG (0.2…4 mm2)Wire Strip Length 0.32 in. (8 mm)Recommended Tightening Torque 3.5…4.5 lb-in. (0.38…0.50 Nm)Operating Temperature Range 0…+60°C
Publication 1492-TD008A-EN-P - March 2001
Digital/Analog Programmable Controller Wiring Systems 205
Notes:
Publication 1492-TD008A-EN-P - March 2001
206 Digital/Analog Programmable Controller Wiring Systems
Notes:
Publication 1492-TD008A-EN-P - March 2001
Publication 1492-TD008A-EN-P - March 2001 2001 Rockwell International. All Rights Reserved. Printed in USA