product news
field module.AS-i Safety at Work
Safe signal detectionand triggeringof the locking mechanism.
Connection of fail-safe inductive sensorsto EN 954-1 / category 4.
1 safe input for ifm sensors,1 switching output for actuators.
Up to 8 fail-safe inductive sensors can beconnected via M12 sockets.
Module with standardised EMS interfacefor AS-i and 24 V.
Data transmission on the AS-i busapproved by TÜV and BIA.
Protective cover on a laser unit
IntroductionThe ClassicLine Safety at Work module connects fail-safe inductive sensors to AS-interface. Evaluation to theSafety at Work protocol is carried out with one of thefour available AS-i safety monitors.The safe data transmission on the AS-i bus has alreadybeen approved by TÜV and BIA and is suitable for thetransfer of signals up to the highest category 4 toEN 954-1.Powerful LEDs on the front panel indicate switchingstates of the inputs and outputs, voltage supply andfaults at the module, if any.The safe AS-interface input module AC016S is approvedfor up to category 4 to EN 954-1.
ClassicLine
Bu
s sy
stem
s
bus,identification
and control systems
positionsensors
and objectdetection
fluid sensorsand diagnostic
systems
The new input module AC016S allows the connectionof fail-safe inductive sensors of ifm electronic up to cat-egory 4 to EN 954-1. This input module enables the con-nection of up to 8 safety-related inductive sensorswithout integrated AS-i interface to the AS-interfacesystem.In addition to the safe input these units also feature aswitching output for actuators which allows magneticguard locking controlled by AS-i.
Advantages and customer benefits
• Diagnosis and self-testThe safe ClassicLine slave carries out a periodic inter-nal self-test after power on. It is transferred as thesafe state to the master (triggered = code sequence“0000”). After power on and successful function testthe Safety at Work protocol is started (not triggered =cyclical transmission of the code table). The safe inputis now ready for operation.During operation the redundantly designed module ispermanently monitored. The input is monitored forcross faults. In case of a fault a red fault LED indicatesthe fault. In addition an AS-i peripheral fault is gener-ated.
• The Safety at Work systemIn principle, the AS-i safety technology consists of twocomponents: Of one safe input slave for connection ofthe safety devices and the safety monitor as a moni-toring element with positively-driven relays for thesafe switch-off of the drives or actuators. The otherAS-i standard components, like master and currentsupply, remain unchanged.
• AddressingAddressing is done before mounting via the adapterintegrated into the addressing unit or after mountingby means of a module lower part with addressingsocket and an addressing cable with a jack plug.Using the ifm controller e addressing is even moreconvenient. The large graphic display gives the user anoptimum overview.
ApplicationThe fail-safe AS-i ClassicLine module can be used in awide range of different applications. It is suitable wheredecentralised I /O, modular design and simplicity of thesystem are important and a high protection ratingagainst environmental influence is required.
Technical data
Operating voltage (AS-i) [V DC] 26.5...31.6
Housing material PBT (Pocan)
Protection rating IP 67
Operating temperature [°C] -25...55
Error indication LED red
Indication AS-i power LED green
Indication FAULT / ALARM LED red
Indication switching status inputs LED yellow
Total current consumption [mA] ≤ 250
Control category to EN 954-1 4
Safe inputs pcs. 1
Transistor outputs pcs. 1
Current rating per output [mA] 500
AS-i reverse polarity protection •
AS-i profile S-7.B.E
ClassicLine Safety at Work moduleAC016S
Products
Designation Orderno.
ClassicLine safety module 1SI 1DO T AC016S
Safety monitor 1-channel, 1SO R AC001S
Safety monitor 2-channel, 2SO R AC002S
Safety monitor, extended, 2-channel AC004S
Safety monitor, extended, 1-channel AC003S
Serial interface cable SUB-D9 / RJ45 E7001S
AC5003
Configuration software for safety monitor E7020S
FC-E coupling module
T-piece for series connection of fail-safe inductive sensors E11569
90
LEDM12 x1
44
80
Dimensions
Bu
s sy
stem
s
Bus system AS-interface
For further technical data please go to: www.ifm-electronic.com
ifm a
rtic
le n
o. 7
5111
03 ·
Prin
ted
in G
erm
any
on n
on-c
hlor
ine
pape
r. ·
We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· 10
.200
5
AC016S