2
HP DXE Power Inverter Heat Pump Air Curtain System Product Information Air Conditioning HP DXE Power Inverter Heat Pump Air Curtain System Key Features Reduced CO 2 emissions (up to 67%) Reduced running costs (up to 67%) 2.5 year payback period against equivalent electric system Inverter technology (does not waste energy) Range of different sizes to suit every application Allows open door policy in retail outlets whilst being energy efficient Clean environment - protection from dust, fumes etc Comfortable climate for customers Easy to install and maintain New centrifugal fan New weather compensation option for further energy efficiency Eligible for ECA In collaboration with Thermoscreens ® , Mitsubishi Electric have developed a new range of air curtains that can be connected to our Power Inverter heat pumps, as opposed to the more traditional direct electric method associated with air curtains.

Product Information Air Conditioning HP DXE Power Inverter ...€¦ · HP DXE - RECESSED 8.3 7.4 1310 50-55-58 52 1250 x 348 x 539 220-240V, 50Hz Single 0.8 3 90 3.3 13.8 12.3 2070

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Information Air Conditioning HP DXE Power Inverter ...€¦ · HP DXE - RECESSED 8.3 7.4 1310 50-55-58 52 1250 x 348 x 539 220-240V, 50Hz Single 0.8 3 90 3.3 13.8 12.3 2070

HP DXE Power InverterHeat PumpAir Curtain System

Product Information

Air Conditioning HP DXE Power Inverter Heat PumpAir Curtain System

Key Features■ Reduced CO2 emissions (up to 67%)■ Reduced running costs (up to 67%)■ 2.5 year payback period against equivalent electric system■ Inverter technology (does not waste energy)■ Range of different sizes to suit every application■ Allows open door policy in retail outlets whilst

being energy efficient■ Clean environment - protection from dust, fumes etc■ Comfortable climate for customers■ Easy to install and maintain■ New centrifugal fan■ New weather compensation option for

further energy efficiency■ Eligible for ECA

In collaboration with Thermoscreens®, Mitsubishi Electric havedeveloped a new range of air curtains that can be connectedto our Power Inverter heat pumps, as opposed to the more traditional direct electric method associated with air curtains.

Page 2: Product Information Air Conditioning HP DXE Power Inverter ...€¦ · HP DXE - RECESSED 8.3 7.4 1310 50-55-58 52 1250 x 348 x 539 220-240V, 50Hz Single 0.8 3 90 3.3 13.8 12.3 2070

Product Information

Air Conditioning HP DXE Power Inverter Heat PumpAir Curtain System

CAPACITy (kw) Heating (nominal) Cooling (nominal)AIR VOLUME MAX (m3/h) SOUND PRESSURE  LEVEL AT 3m (dBA) Lo-Mi1-HiwEIGHT (kg)DIMENSIONS (mm) Width x Depth x HeightELECTRICAL SUPPLy*1 PHASE*1

RUNNING CURRENT (A)*1

MAINS CABLE No. Cores*1

UNIFORMITy AT OUTLET  (%)*2

MAX MOUNTING HEIGHT (m)

HP DXE - RECESSED8.37.4

131050-55-58

521250 x 348 x 539220-240V, 50Hz

Single0.83

903.3

13.812.32070

49-54-5875

1750 x 348 x 539220-240V, 50Hz

Single1.23

923.3

13.812.32070

49-54-5875

1750 x 348 x 539220-240V, 50Hz

Single1.23

923.3

15.914.22590

50-55-5893

2340 x 348 x 539220-240V, 50Hz

Single1.43

903.3

HP1000R DXE HP1500R DXE HP1500R DXE HP2000R DXE

CAPACITy (kw) Heating (nominal) Cooling (nominal)AIR VOLUME MAX (m3/h) SOUND PRESSURE  LEVEL AT 3m (dBA) Lo-Mi1-HiwEIGHT (kg)DIMENSIONS (mm) Width x Depth x HeightELECTRICAL SUPPLy*1 PHASE*1

RUNNING CURRENT (A)*1

MAINS CABLE No. Cores*1

UNIFORMITy AT OUTLET  (%)*2

MAX MOUNTING HEIGHT  (m)

HP DXE - FREE STANDING8.37.4

131050-55-58

461300 x 468 x 306220-240V, 50Hz

Single0.83

903.3

13.211.82070

49-54-5867

1825 x 468 x 306220-240V, 50Hz

Single1.23

923.3

13.211.82070

49-54-5867

1825 x 468 x 306220-240V, 50Hz

Single1.23

923.3

15.714.02590

50-55-5884

2350 x 468 x 306220-240V, 50Hz

Single1.43

903.3

PRICE

HP1000 DXE HP1500 DXE HP1500 DXE HP2000 DXE

21.018.72590

50-55-5893

2340 x 348 x 539220-240V, 50Hz

Single1.43

903.3

HP2000R DXE

21.018.72590

50-55-5893

2350 x 468 x 306220-240V, 50Hz

Single1.43

903.3

HP2000 DXE

SOUND PRESSURE LEVEL (dBA) Heating/CoolingSOUND POwER LEVEL (dBA) CoolingwEIGHT (kg)DIMENSIONS (mm) Width x Depth x HeightELECTRICAL SUPPLyPHASESTARTING CURRENT (A)FUSE RATING (BS88) - HRC (A)INTERCONNECTING CABLEMAX PIPE LENGTH (m)MAX HEIGHT DIFFERENCE (m)CHARGE R410A (kg) - 30m

HEAT PUMP OUTDOOR UNITS48 / 47

6767

950 x 330 +30 x 943220-240V, 50Hz

Single5

252 Core

50303.5

52 / 5070

1161050 x 330 +30 x 1338

220-240V, 50HzSingle

532

2 Core75305.0

52 / 5070

1261050 x 330 +30 x 1338

380-415V, 50HzThree

516

2 Core75305.0

PUHZ-ZRP71VHA PUHZ-ZRP125VKA PUHZ-ZRP125YKAThree Phase

52 / 5070

1321050 x 330 +30 x 1338

380-415V, 50HzThree

516

2 Core75305.0

PUHZ-ZRP140YKAThree Phase

59 / 58-

1351050 x 330 +30 x 1338

380-415V, 50HzThree

520

2 Core100305.0

PUHZ-RP200YKAThree Phase

333

15.914.22590

50-55-5893

2340 x 348 x 539220-240V, 50Hz

Single1.43

903.3

HP2000R DXE

15.714.02590

50-55-5884

2350 x 468 x 306220-240V, 50Hz

Single1.43

903.3

HP2000 DXE

52 / 5070

1191050 x 330 +30 x 1338

220-240V, 50HzSingle

540

2 Core75305.0

PUHZ-ZRP140VKA

UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems DivisionTravellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, IrelandTelephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)

Telephone: 01707 282880email: [email protected] web: airconditioning.mitsubishielectric.co.uk

Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2014. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves theright to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developingand improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject tothe Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Effective as of May 2014

Notes: *1 For indoor units with electric heaters enabled, 380-415V 3ph power supply (7.3A HP1000, 12.1A HP1500, 14.4A HP2000). *2 Tested to ISO 27327.

Three Phase3