25
erlab ® - 10/2009 - . All data or photographs in this brochure are not contractual. erlab ® reserves the right to modify the present document without prior notice. Product guide EUROPE FRANCE : erlab D.F.S. S.A.S. Headquarter Parc d’Affaires des Portes BP 403 27104 Val de Reuil Cedex Tel. : +33 (0)2 32 09 55 80 Fax. : +33 (0)2 32 09 55 90 E-Mail :[email protected] U.K. : erlab D.F.S. S.A.S. UK and Ireland representation office Home Farm Buildings / Home Farm Netherhampton - Salisbury - SP2 8PJ Tel. : +44 (0)1722 341 940 Fax. : +44 (0)1722 341 950 E-Mail : [email protected] GERMANY : erlab D.F.S. S.A.S. Vertretungsbüro Deutschland Siegburger Straße 215 - 50679 Köln Tel. : (0)800 330 47 31 Fax : (0)800 330 47 32 E-Mail :[email protected] Aus Österreich und der Schweiz: Tel: +33 (0)2 32 09 55 80 Fax: +33 (0)2 32 09 55 90 ITALY : erlab D.F.S. S.A.S. Ufficio di rappresentanza in Italia Via Leone XIII, 10 – 20145 Milano Tel. : +39 (0)2 89 00 771 Fax. : +39 (0)2 72 097 812 E-Mail :[email protected] SPAIN : erlab S.L. Pol. Ind. Sur Passaje Newton 3A 08754 El Papiol-Barcelona Tel. : +34 93 673 24 74 Fax. : +34 93 673 24 76 E-Mail :[email protected] NORTH AMERICA U.S.A. : erlab inc. 388 Newburyport Turnpike Rowley, MA 01969 Tel : +1 (978) 948-2216 Fax : +1 (978) 948-3354 E-mail : [email protected] ASIA CHINA : Kunshan erlab D.F.S. co Ltd. 100 Liu Shi Jing, road Kunshan Development Zone Jiangsu Province Penglang - P.R. China 215333 Tel. : +86 (0) 512 5781 4085 Fax. : +86 (0) 512 5781 4082 E-mail : [email protected] MALAYSIA : erlab asia sdn bhd 25 Jalan Firma - /1 Kawasan Perindustrian Tebrau - 81 100 Johor Bahru, Johor State Tel. : +60 (0)7 3 555 724 Fax. : +60 (0)7 3 552 810 E-Mail : [email protected] www. .com International sales [email protected] TM Product Guide

Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

erla

b® -

10/2

009

- . A

ll da

ta o

r ph

otog

raph

s in

this

broc

hure

are

not

con

trac

tual.

erl

ab® r

eser

ves

the

right

to m

odify

the

pres

ent d

ocum

ent w

ithou

t prio

r no

tice.

Prod

uct g

uide

EUROPE

FRANCE : erlab D.F.S. S.A.S. Headquarter Parc d’Affaires des Portes BP 403 27104 Val de Reuil Cedex Tel. : +33 (0)2 32 09 55 80 Fax. : +33 (0)2 32 09 55 90 E-Mail : [email protected]

U.K. : erlab D.F.S. S.A.S. UK and Ireland representation office Home Farm Buildings / Home Farm Netherhampton - Salisbury - SP2 8PJ Tel. : +44 (0)1722 341 940 Fax. : +44 (0)1722 341 950 E-Mail : [email protected]

GERMANY : erlab D.F.S. S.A.S. Vertretungsbüro Deutschland Siegburger Straße 215 - 50679 Köln Tel. : (0)800 330 47 31 Fax : (0)800 330 47 32 E-Mail : [email protected] Aus Österreich und der Schweiz: Tel: +33 (0)2 32 09 55 80 Fax: +33 (0)2 32 09 55 90

ITALY : erlab D.F.S. S.A.S. Ufficio di rappresentanza in Italia Via Leone XIII, 10 – 20145 Milano Tel. : +39 (0)2 89 00 771 Fax. : +39 (0)2 72 097 812 E-Mail : [email protected]

SPAIN : erlab S.L. Pol. Ind. Sur Passaje Newton 3A 08754 El Papiol-Barcelona Tel. : +34 93 673 24 74 Fax. : +34 93 673 24 76 E-Mail : [email protected]

NORTH AMERICA

U.S.A. : erlab inc. 388 Newburyport Turnpike Rowley, MA 01969 Tel : +1 (978) 948-2216 Fax : +1 (978) 948-3354 E-mail : [email protected]

ASIA

CHINA : Kunshan erlab D.F.S. co Ltd. 100 Liu Shi Jing, road Kunshan Development Zone Jiangsu Province Penglang - P.R. China 215333 Tel. : +86 (0) 512 5781 4085 Fax. : +86 (0) 512 5781 4082 E-mail : [email protected] MALAYSIA : erlab asia sdn bhd 25 Jalan Firma - /1 Kawasan Perindustrian Tebrau - 81 100 Johor Bahru, Johor State Tel. : +60 (0)7 3 555 724 Fax. : +60 (0)7 3 552 810 E-Mail : [email protected]

w w w . . c o m

International [email protected]

TM

Product Guide

Page 2: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

321Midcap

M

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

OptionsWork surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

External lighting Pivoting - 11 Watts - 400 Lux - IP 20

Mobicap Rolling cart made of anti-corrosion metallic alloy

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel

Acrylic

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Equipments

Compliance to standards

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 8 mm thick acrylic

Filtration module Polypropylene

SpecificationsNumber of columns 1Number of fans (IP44) 1Processed air flow 230 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 45 watts(without lighting)

Amperage absorbed 1,6 amp.Sound level 52 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height Width Depth Height

MidcapM 321

800 620 1120 764 540 860

Types of filters available

The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

Molecular filter H14 HEPA filter

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

Modular filtration columnMolecular filtration efficiency in

compliance with NFX 15-211: 2009 class 2 standard

H14 HEPA Filtration

Type 1CLiquid chemicals handlings

Type 1PPowders handlings

Page 3: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

321Midcap

M

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

*

* Total height according to filtration column type (mm)

Type 1P 1120Type 1C 1120

800 mm

192 mm

172 mm

332 mm

255 mm

764 mm

613 mm

1120 mm mini

1290 mm maxi

540 mm

620 mm

74 mm

420 mm

860 mm

30 mm

Page 4: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

321Midcap

M

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

Work surface N°1

Work surface N°2

540 mm

25 mm

764 mm

694 mm

540 mm

55 mm

764 mm

Page 5: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

321 M

www.captair.com

TM

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

Equipments

Compliance to standards

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 8 mm thick acrylic

Filtration module Polypropylene

SpecificationsNumber of columns 1Number of fans (IP44) 1Processed air flow 230 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 45 watts(without lighting)

Amperage absorbed 1,6 amp.Sound level 52 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

M 321 800 6201120 mini1290 maxi

764 540 860

Types of filters available

The guarantee of your protection will be only ensured after the erlab®laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Modular filtration column

Type 1PPowders handlings

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Mobicap Rolling cart made of anti-corrosion metallic alloy

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel

Acrylic

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Page 6: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

321 M

www.captair.com

TM

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

*

* Total height according to filtration column type (mm)

Type 1P 1120 Type 2C 1220Type 1C 1120 Type 1P 2C 1290Type 1P 1C 1220 Type 2C 1P 1290Type 1C 1P 1220

800 mm

192 mm

172 mm

332 mm

255 mm

764 mm

613 mm

1120 mm mini

1290 mm maxi

540 mm

620 mm

74 mm

420 mm

860 mm

30 mm

*

Page 7: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

321 M

www.captair.com

TM

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

Work surface N°1

Work surface N°2

540 mm

25 mm

764 mm

694 mm

540 mm

55 mm

764 mm

Page 8: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

391 M

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

TM

Equipments

Compliance to standards

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 6 mm thick acrylic

Filtration module Polypropylene

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

M 391 1000 6201120 mini1290 maxi

965 540 860

Types of filters available

The guarantee of your protection will be only ensured after the erlab®laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Mobicap Rolling cart made of anti-corrosion metallic alloy

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel Acrylic

Access door on rear panel For maintenance interventions

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

SpecificationsNumber of columns 1Number of fans (IP44) 1Processed air flow 230 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 45 watts(without lighting)

Amperage absorbed 1,6 amp.Sound level 52 dbA

Modular filtration column

Type 1PPowders handlings

Page 9: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

391 M

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

TM

1000 mm

192 mm

172 mm

332 mm

255 mm

965 mm

613 mm

1120 mm mini

1290 mm maxi

540 mm

620 mm

74 mm

420 mm

860 mm

30 mm

* Total height according to filtration column type (mm)

Type 1P 1120 Type 2C 1220Type 1C 1120 Type 1P 2C 1290Type 1P 1C 1220 Type 2C 1P 1290Type 1C 1P 1220

Page 10: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

391 M

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

TM

Work surface N°1

Work surface N°2

540 mm

965 mm

80 mm

965 mm

896 mm

580 mm

60 mm

Page 11: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

481 M

www.captair.com

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

TM

Equipments

Compliance to standards

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 6 mm thick acrylic

Filtration module Polypropylene

SpecificationsNumber of columns 1

Number of fans (IP44) 1

Processed air flow 230 m3/h

Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 45 watts(without lighting)

Amperage absorbed 1,6 amp.

Sound level 52 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

M 481 1275 6201120 mini1290 maxi

1240 540 860

Types of filters available

The guarantee of your protection will be only ensured after the erlab®laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel Acrylic

Access door on rear panel For maintenance interventions

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Page 12: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

481 M

www.captair.com

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

TM

1275 mm

192 mm

172 mm

332 mm

255 mm

1240 mm

613 mm

1120 mm mini

1290 mm maxi

540 mm

620 mm

74 mm

420 mm

860 mm

30 mm

* Total height according to filtration column type (mm)

Type 1C 1120 Type 2C 1220Type 1P 1C 1220 Type 1P 2C 1290Type 1C 1P 1220 Type 2C 1P 1290

Page 13: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

481 M

www.captair.com

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

TM

Work surface N°1

Work surface N°2

1240 mm

540 mm

80 mm

1170 mm

540 mm

60 mm

1240 mm

Page 14: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

392 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

Modular filtration column

Type 1PPowders handlings

Equipments

Compliance to standards

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 6 mm thick acrylic

Filtration module Polypropylene

SpecificationsNumber of columns 2Number of fans (IP44) 2Processed air flow 460 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 90 watts(without lighting)

Amperage absorbed 3,6 amp.Sound level 55 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

XLS 392

1000 7901290 mini1470 maxi

965 680 1038

Types of filters available

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel Acrylic

Access door on rear panel For maintenance interventions

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Page 15: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

392 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

897 mm

274 mm

1000 mm

965 mm

958 mm

1290 mm mini

1470 mm maxi

680 mm

790 mm

74 mm

660 mm

1038 mm

30 mm

*

*

* Total height according to filtration column type (mm)

Type 1P 1290 Type 2C 1398Type 1C 1290 Type 1P 2C 1470Type 1P 1C 1378 Type 2C 1P 1470Type 1C 1P 1378

Page 16: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

392 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

680 mm

965 mm

80 mm

965 mm

896 mm

680 mm

60 mm

Work surface N°1

Work surface N°2

Page 17: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

483 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

Modular filtration column

Type 1PPowders handlings

Equipments

Compliance to standards

SpecificationsNumber of columns 3Number of fans (IP44) 3Processed air flow 690 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 135 watts (without lighting)

Amperage absorbed 4,8 amp.Sound level 58 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

XLS 483

1275 7901290 mini1470 maxi

1240 680 1038

Types of filters available

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 6 mm thick acrylic

Filtration module Polypropylene

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel Acrylic

Access door on rear panel For maintenance interventions

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Page 18: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

483 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

1275 mm

325 mm

1240 mm

958 mm

1290 mm mini

1470 mm maxi

680 mm

790 mm

74 mm

660 mm

1038 mm

30 mm

*

*

* Total height according to filtration column type (mm)

Type 1P 1290 Type 2C 1398Type 1C 1290 Type 1P 2C 1470Type 1P 1C 1378 Type 2C 1P 1470Type 1C 1P 1378

Page 19: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

483 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

1240 mm

680 mm

80 mm

1170 mm

60 mm

1240 mm

680 mm

Work surface N°1

Work surface N°2

Page 20: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

633 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

Equipments

Compliance to standards

SpecificationsNumber of columns 3Number of fans (IP44) 3Processed air flow 690 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 135 watts (without lighting)

Amperage absorbed 4,8 amp.Sound level 58 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

XLS 633

1600 7901290 mini1470 maxi

1566 680 1038

Types of filters available

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 6 mm thick acrylic

Filtration module Polypropylene

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel Acrylic

Access door on rear panel For maintenance interventions

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Page 21: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

633 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

1600 mm

1566 mm

1300 mm

280 mm

* Total height according to filtration column type (mm)

Type 1C 1290 Type 2C 1398Type 1P 1C 1378 Type 1P 2C 1470Type 1C 1P 1378 Type 2C 1P 1470

958 mm

1290 mm mini

1470 mm maxi

680 mm

790 mm

74 mm

660 mm

1038 mm

30 mm

*

*

Page 22: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

633 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

1566 mm

80 mm

680 mm

1566 mm

1494 mm

680 mm

60 mm

Work surface N°1

Work surface N°2

Page 23: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

714 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

Equipments

Compliance to standards

SpecificationsNumber of columns 4Number of fans (IP44) 4Processed air flow 920 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s

Voltage / Frequency 220 V / 50 Hz

Total power consumption 180 watts (without lighting)

Amperage absorbed 6,4 amp.Sound level 61 dbA

Technical specifications

Dimensions (mm)

Ref.External dimensions Internal dimensions - without work surface

Width Depth Height* Width Depth Height

XLS 714

1800 7901290 mini1470 maxi

1765 680 1038

Types of filters available

*According to filtration column type

Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)

Type 1CLiquid chemicals handlings

Type 2C Liquid chemicals handlings

Type 1P 1CLiquid chemicals and powders handlings

Type 1P 2CLiquid chemicals and powders handlings

Type 1C 1PLiquid chemicals and powders handlings in clean room

Type 2C 1PLiquid chemicals and powders handlings in clean room

Molecular filter H14 HEPA filter

AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada

CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )

GF4 AS For organic vapours

GF4 BE + For organic vapours + acid vapours

GF4 F For formaldehyde vapours

GF4 K For ammonia vapours

GF4 HP H14 HEPA Filter for powders

The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

Modular filtration column

Type 1PPowders handlings

Structure

Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and front panels 6 mm thick acrylic

Filtration module Polypropylene

Standard Equipment

Air flow meter Permanent air face velocity monitoring system

Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard

Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68

Sampling port For filter saturation detection (N/A if Molecode S installed)

Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard

Energy ports For the passage of cables

Chemical Listing List of approved chemicals

Options

Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Work surface N°1 Tempered glass work surface with seeled frame

Work surface N°2 In phenolic resin with built-in retention tray

Benchcap Fixed work bench made of anti-corrosion metallic alloy

Shelf Adjustable slinding shelf for Mobicap and Benchcap

Transparent back panel Acrylic

Access door on rear panel For maintenance interventions

Particular Pre-filter

40 % filtration efficiency for particles > 0,3 µm

Page 24: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

714 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

1800 mm

1765 mm

300 mm

1715 mm

958 mm

1290 mm mini

1470 mm maxi

680 mm

790 mm

74 mm

660 mm

1038 mm

30 mm

*

*

* Total height according to filtration column type (mm)

Type 1P 1290 Type 2C 1398Type 1C 1290 Type 1P 2C 1470Type 1P 1C 1378 Type 2C 1P 1470Type 1C 1P 1378

Page 25: Product Guide - Lab Unlimited · erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - France Tel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32

714 XLS

erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]

Please consider the environment before printing this document.P

Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.

Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.

Tech

nica

l dat

a ar

e no

t co

ntra

ctua

l. E

rlab

® r

eser

ves

the

righ

t to

mod

ify t

he p

rese

nt d

ocum

ent

with

out

prio

r no

tice.

TM

www.captair.com

1765 mm

80 mm

680 mm

1765 mm

1694 mm

680 mm

60 mm

Work surface N°1

Work surface N°2