24
Product Data 38CKC (50 Hz) 10 SEER Air Conditioner Export Model 1---1/2 to 5 Nominal Tons (5.2 to 17.5 kW) Model 38CKC 50 Hertz energy efficient air conditioner incorporates innovative technology to provide reliable summer cooling performance. Built into these units are the features most desired by customers today, including EER ratings of up to 9.5 when used with components designated by manufacturer. FEATURES AND BENEFITS ELECTRICAL RANGE 230v single phase units are available sizes 018 through 036. 400v three--phase units are available in sizes 036 through 060. WIDE RANGE OF SIZES The 38CKC is available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. WEATHERARMORt CABINET A weather protective cabinet of pre--painted steel is protected underneath by a zinc galvanized coating for a finish that will last for many years. All screws on cabinet exterior are coated for a long--lasting, rust--resistant, quality appearance. TOTALLY ENCLOSED FAN MOTOR Provides greater reliability under adverse conditions and dependable performance for many years. The permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest reliability. UNIT DESIGN Aluminum fin material is pre--coated on both sides with a corrosion protective coating, capable of 1000 hr salt spray exposure per ASTM B117 test Copper tube, enhanced sine wave aluminum coated fin coil is designed for optimum heat transfer and corrosion protection. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style drain pan allows for easy removal of water, dirt, and leaves. APPLICATION VERSATILITY The unit can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. Unit can be installed on a roof or at ground level. EXTERNAL SERVICE VALVES Service valves are brass, front seating type. The 38CKC has sweat field connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures.

Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

Product Data

38CKC (50 Hz)10 SEER Air ConditionerExport Model1---1/2 to 5 Nominal Tons (5.2 to 17.5 kW)

Model 38CKC 50 Hertz energy efficient air conditionerincorporates innovative technology to provide reliable summercooling performance. Built into these units are the features mostdesired by customers today, including EER ratings of up to 9.5when used with components designated by manufacturer.

FEATURES AND BENEFITSELECTRICAL RANGE230v single phase units are available sizes 018 through 036. 400vthree--phase units are available in sizes 036 through 060.

WIDE RANGE OF SIZESThe 38CKC is available in 7 nominal sizes from 018 through 060to meet the needs of residential and light commercial applications.

WEATHERARMORt CABINETA weather protective cabinet of pre--painted steel is protectedunderneath by a zinc galvanized coating for a finish that will lastfor many years. All screws on cabinet exterior are coated for along--lasting, rust--resistant, quality appearance.

TOTALLY ENCLOSED FAN MOTORProvides greater reliability under adverse conditions anddependable performance for many years. Thepermanent--split--capacitor--type motor is designed for optimumefficiency. The motor is tested and qualified under extremeconditions to ensure the greatest reliability.

UNIT DESIGNAluminum fin material is pre--coated on both sides with acorrosion protective coating, capable of 1000 hr salt sprayexposure per ASTM B117 test

Copper tube, enhanced sine wave aluminum coated fin coil isdesigned for optimum heat transfer and corrosion protection.Vertical air discharge carries sound and hot condenser air up andaway from adjacent patio areas and foliage. Heat pump style drainpan allows for easy removal of water, dirt, and leaves.

APPLICATION VERSATILITYThe unit can be combined with a wide variety of evaporator coilsand blower packages to provide quiet, dependable comfort. Unitcan be installed on a roof or at ground level.

EXTERNAL SERVICE VALVESService valves are brass, front seating type. The 38CKC has sweatfield connections. Valves are externally located so refrigerant tubeconnections can be made quickly and easily. Each valve has aservice port for ease of checking operating refrigerant pressures.

Page 2: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

2

FEATURES AND BENEFITS (CONT.)

EASY SERVICEABILITYOne panel provides access to electrical controls. Removal of wiredome gives access to fan motor and removal of the top gives accessto the coil and compressor.

PRESSURE SWITCHESAll units are equipped with high and low pressure switches.

COMPRESSOR PROTECTIONEach compressor is protected with internal temperature-- andcurrent--sensitive overloads.

3--PHASE MONITOR BOARDControl board that monitors the electrical phase and preventsoperation if wired incorrectly. Standard on 3--phase 048 and 060sizes.

OPERATING RANGEMinimum outdoor operating ambient in cooling mode is 55_F(12.8_C), maximum is 125_F (51.7_C).

PRODUCT NUMBER NOMENCLATURE38CKC 024 7

Electric Air Conditioner

Electrical Supply7=230---1---509=400---3---50

X

X = Export

3

Packaging

Series

A

Nominal Capacity018 --- 18,000 Btuh (5.3 kW)024 --- 24,000 Btuh (7.0 kW)030 --- 30,000 Btuh (8.8 kW)036 --- 36,000 Btuh (10.6 kW)042 --- 42,000 Btuh (12.3 kW)048 --- 48,000 Btuh (14.1 kW)060 --- 60,000 Btuh (17.6 kW)

38CKC

Page 3: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

3

PHYSICAL DATA

Unit Size 018---7D 024---7D 030---7D 036---7D, 9D 042---9D 048---7C, 9C 060---9COPERATING WEIGHT (lb/kg) 120 / 54.5 130 / 59.1 140 / 63.6 152 / 69.1 175 / 79.5 213 / 96.8 219 / 99.5COMPRESSOR TYPE Recip ScrollREFRIGERANT R---22Control AccuRaterrCharge (Lb) @ 15 Ft./4.6m 3.76 / 1.71 3.41 / 1.55 5.00 / 2.27 4.84 / 2.20 6.25 / 2.84 6.25 / 2.84 9.10 / 4.13

COND FAN Propeller Type, Direct DriveAir Discharge VerticalAir Qty (CFM/L/S) 1600 / 755 2000 / 944 3200 / 1510

COND COIL Copper Tube, Aluminum Plate FinFace Area sq ft / sq m 6.2 / 0.58 7.5 / 0.70 9.1 / 0.85 12.4 / 1.15 14.8 / 1.37 22.2 / 2.06

VALVE CONNECTION(in./mm)lD Sweat

Vapor 5/8 / 15.88 3/4 / 19.05 7/8 / 22.23Liquid 3/8 / 9.53

REFRIG. TUBES*(in./mm) ODVapor(0---50 ft/0---15.24m Tube) 5/8 / 15.88 3/4 / 19.05 7/8 / 22.23 1---1/8 /

28.58Liquid(0---50 ft./0---15.24 m/ TubeLength)

3/8 / 9.53

* Tube sizes are for runs up to 50 ft (15.24m). For tube set over 50 ft (15.24m), consult Residential Split ---System Long---Line Application Guideline.NOTE: See unit Installation Instructions for proper installation.

METERING DEVICEUNIT SIZE --- VOLTAGE,SERIES PISTON IDENTIFICATION NO. REQUIRED SUB---COOLING F(C)

with TXV Expansion Device018---7D 57 8 (4.4)024---7D 63 11 (6.1)030---7D 70 12 (6.7)036---7D, 9D 73 16 (8.9)042---9D 78 12 (6.7)048---7C, 9C 90 14 (7.8)060---9C 98 11 (6.1)

* Piston listed is for any approved non---capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil.

A--WEIGHTED SOUND POWER (dBA)

UNIT SIZE--- VOLTAGE, SERIESSTANDARDRATING(dBA)

TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)

125 250 500 1000 2000 4000 8000018---7D 77 59.0 66.0 69.0 71.5 70.0 65.0 58.5024---7D 77 52.0 65.5 67.0 69.0 68.0 68.5 63.0030---7D 77 55.0 64.5 71.0 72.0 70.5 69.0 62.5036---7D, 9D 78 59.0 68.0 68.0 72.5 73.0 71.0 67.0042---9D 78 59.0 66.5 68.5 75.5 74.5 73.0 65.5048---7C, 9C 78 62.5 64.0 70.5 73.5 72.5 70.5 66.5060---9C 78 58.5 66.0 69.0 73.0 70.0 70.5 66.5

38CKC

Page 4: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

4

ACCESSORIESPART NO. DESCRIPTION

KSAHS1001AAA Start Assist --- Capacitor/Relay --- Sizes 018, 024KSAHS1301AAA Start Assist --- Capacitor/Relay --- Size 030, 036 (7D)KAACS0101PTC Start Assist --- PTC --- Sizes 018, 024KAACS0201PTC Start Assist --- PTC --- Sizes 030, 036 (7D), 048 (7C)KAALS0101LLS* Liquid Solenoid Valve --- All SizesKSACY0101AAA Cycle Protector --- All SizesKAAWS0101AAA Winter Start Control --- All SizesKAAFT0101AAA Evaporator Freeze Thermostat --- All SizesKAATD0101TDR Time---Delay Relay --- All SizesKSASF0101AAA Support Feet --- All SizesKAACH1001AAA Crankcase Heater --- Sizes 018, 024, 030, 036 (7D) , 048 (7C)KAACH1101AAA Crankcase Heater--- Sizes 036 (9D)KAACH1301AAA Crankcase Heater--- Sizes 042, 048 (9C), 060KAACF0701SML Coastal Filter --- Size 018KAACF1001MED Coastal Filter --- Sizes 024, 030, 036KAACF1101LRG Coastal Filter --- Sizes 042, 048, 060KSATX0601HSO* Thermostatic Expansion Valve (Hard Shutoff) --- Sizes 018, 024, 030, 036, 042KSATX0701HSO* Thermostatic Expansion Valve (Hard Shutoff) --- Size 048KSATX1001HSO* Thermostatic Expansion Valve (Hard Shutoff) --- Size 060KSALA0201R22 Low---Ambient Pressure Switch (R22) --- All SizesKSALA0401AAA MotorMaster Control --- 024, 030, 036 (7C), 048 (7C)KSALA0501AAA MotorMaster Control --- 036 (9A), 042, 048 (9C), 060KH45LD060 Filter Drier --- 018---042KH45LE062 Filter Drier --- 048, 060KSASH1201COP Sound Shield --- 036KSASH2101COP Sound Shield --- 042, 048, 060* Do not use hard shutoff TXV with liquid solenoid valve.

ACCESSORY THERMOSTATSPART NUMBER PROGRAM ELECTRIC HEAT COOLTB---PAC01 5---2 Day √ 1 1TB---NAC01 NP 1 1

THERMOSTAT ACCESSORIESPART NUMBER BRIEF DESCRIPTION THERMOSTATS USED WITHTSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) --- 10 pack All Carrier branded thermostatsTX---MBP01 Medium Decorative Backplate TC---Nxx, TB---PxxTX---SBP01 Small Decorative Backplate TB---Nxx

38CKC

Page 5: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

5

ACCESSORY USAGE GUIDELINE

ACCESSORYREQUIRED FOR LOW---AMBI-ENT COOLING APPLICATIONS

(Below 55F/12.8_C)

REQUIRED FOR LONGLINE

APPLICATIONS*(Over 80 ft./24.38 m)

REQUIRED FORSEA COASTAPPLICATIONS

(Within 2 miles/3.22 km)Ball Bearing Fan Motor Yes{ No No

Compressor Start Assist Capacitor and Relay Yes{ Yes NoCrankcase Heater Yes{ Yes No

Evaporator Freeze Thermostat Yes{ No NoHard Shut---Off TXV Yes{ Yes Yes

Liquid Line Solenoid Valve No No NoMotor Master Control or

Low---ambient Pressure Switch Yes{ No No

Support Feet Recommended No Recommended* For tubing line sets between 50 (15.24 m) and 175 ft (53.34 m) and/or 20 ft (6.1 m) vertical differential, refer to Residential Split Systems Long---LineApplication Guideline.

{ Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control.

ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY)1. Ball--Bearing Fan Motor

A fan motor with ball bearings, which permits speedreduction while maintaining bearing lubrication.

Usage Guideline:

Required on all units when Motor MasterrLow--Ambient Controller is installed.

2. Coastal FilterA mesh screen inserted under the top cover and inside thebase pan to protect the condenser coil from salt damagewithout restricting airflow.

3. Compressor Start Assist -- Capacitor and RelayStart capacitor and relay gives a ”hard” boost to compressormotor at each start up.

Usage Guideline:Required for reciprocating compressors in the followingapplications:

Long lineLow ambientHard shut off expansion valve on indoor coil

Liquid line solenoid on indoor coilRequired for scroll compressors in the followingapplications:

Long lineLow ambient

Suggested for all compressors in areas with a history oflow voltage problems.

4. Compressor Start Assist -- PTC TypeSolid--state electrical device which gives a ”soft” boost tothe compressor motor at each start up.

Usage Guideline:Suggested when compressor power supply is marginalSuggested in reciprocating compressor applications with

rapid pressure balance (RPB) expansion valve onindoor coil.

5. Crankcase HeaterAn electric resistance heater which mounts to the base of thecompressor to keep the lubricant warm during off cycles.Improves compressor lubrication on restart and minimizesthe chance of liquid slugging.

Usage Guideline:Required in low ambient applications.

Required in long line applications.Suggested in all commercial applications.

6. Evaporator Freeze ThermostatAn SPST temperature--actuated switch that stops unitoperation when evaporator reaches freeze--up conditions.

Usage Guideline:

Required when low ambient kit has been added.7. Filter Drier--Bi--Flow

A device for removing contaminants from refrigerantcirculating in an air conditioning system: single--directionflow.

Usage Guideline:

Suggested in all field--connected split--system airconditioners.

8. High--Pressure SwitchAuto reset SPST switch activated by refrigerant pressure onhigh side of refrigerant circuit. Cycles compressor off ifrefrigerant pressure rises to 426 10 psig and resets at 320 20 psig. Provides protection against compressor damagedue to loss of outdoor airflow.

Usage Guideline:

Suggested in installations exposed to ”very dirty”outdoor air.Suggested in installations where condenser inlet airtemperature exceeds 125_F. (51.7_C)

38CKC

Page 6: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

6

ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY) (CONT.)

9. Liquid--Line Solenoid Valve (LLS)This device serves two purposes. It is an electricallyoperated shutoff valve which stops and starts refrigerantliquid flow in response to compressor operation.

It maintains a column of refrigerant liquid ready for action atnext compressor operation cycle. It also provides systemprotection against off--cycle refrigerant migration.

NOTE: When LLS is used with reciprocating compressors,Compressor Start Assist -- Capacitor and Relay is required.

Usage Guideline:

Required in air conditioner long line applications with apiston indoor metering device to prevent off cyclerefrigerant migration. A hard shut off TXV can be usedinstead of LLS in single flow air conditionerapplications. See Long Line Application Guideline.

10. Low--Ambient Pressure SwitchA long life pressure switch which is mounted to outdoorunit service valve. It is designed to cycle the outdoor fanmotor in order to maintain head pressure within normaloperating limits (approximately 100 psig to 225 psig). Thecontrol will maintain working head pressure at low--ambienttemperatures down to 0_F (--17.8_C) when properlyinstalled.

Usage Guideline:A Low--Ambient Pressure Switch or Motor Masterr --Low--Ambient Controller must be used when coolingoperation is used at outdoor temperatures below 55_F(12.8_C).

11. MotorMasterr--Low--Ambient ControllerA fan speed control device activated by a temperaturesensor, designed to control condenser fan motor speed inresponse to the saturated, condensing temperature duringoperation in cooling mode only. For outdoor temperaturesdown to --20_F (--28.9_C), it maintains condensingtemperature at 100_F 10_F (37.8_C 5.5_C).

Usage Guideline:A Motor Masterr -- Low--Ambient Controller orLow--Ambient Pressure Switch must be used whencooling operation is used at outdoor temperatures below55_F (12.8_C).Suggested for all commercial applications.

12. Outdoor Air Temperature SensorDesigned for use with Carrier Thermostats listed in thispublication. The device enables the thermostat to displaythe outdoor temperature. This device also is required toenable special thermostat features such as auxiliary heatlock out.

Usage Guideline:

Suggested for all Carrier thermostats listed in thispublication.

13. Sound HoodWraparound sound reducing cover for the compressor.Reduces the sound level by about 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft (4.57m) to quiet areas, bedrooms, etc.Suggested when unit is installed between two houses lessthan 10 ft (3.05 m) apart.

14. Thermostatic Expansion Valve (TXV) Single--FlowA modulating flow--control valve which meters refrigerantliquid flow rate into the evaporator in response to thesuperheat of the refrigerant gas leaving the evaporator. Kitincludes valve, adapter tubes, and external equalizer tube.Both hard shutoff and RPB valves are available.NOTE: When using a hard shut off TXV with single phasereciprocating compressors, a Compressor Start Assist --Capacitor and Relay is required.

Usage Guideline:Required to achieve ARI ratings in certain equipmentcombinations. Refer to combination ratings.

Hard shut off TXV or LLS required in air conditionerlong line applications.Required for use on all zoning systems.

15. Time--Delay RelayAn SPST delay relay which briefly continues operation ofindoor blower motor to provide additional cooling after thecompressor cycles off.NOTE: Most indoor unit controls include this feature. Forthose that do not, use the guideline below.

Usage Guideline:For improved efficiency ratings for certain combinationsof indoor and outdoor units. Refer to ARI UnitaryDirectory.

38CKC

Page 7: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

7

DIM

EN

SIO

NS

(EN

GL

ISH

)

EN

F

G_M

A

B

P

1 1/4"

L

J

H

KC

2 7/8"

UNIT

SERI

ESEL

ECTR

ICAL

CHAR

ACTE

RIST

ICS

AB

CD

EF

GH

JK

LM

NP

SHIP

PING

WEI

GHT

38CK

C018

XO

OO

18"

23 15

/16"

3 3/16

"5/8

"3"

15"

7 13/1

6"7/1

6"1 1

1/16"

1 7/8"

1/4"

9 5/8"

10 1/

8"9 1

/2"12

0#

38CK

C024

XO

OO

22 1/

2"21

15/16

"3 3

/16"

5/8"

3 11/1

6"18

1/8"

8 1/8"

7/16"

2 3/4"

2 15/1

6"1/4

"11

3/4"

12 1/

8"10

3/4"

131#

38CK

C030

XO

OO

22 1/

2"25

15/16

"3 3

/16"

3/4"

3 11/1

6"18

1/8"

8 1/8"

7/16"

2 3/4"

2 15/1

6"1/4

"11

3/4"

12 1/

8"11

1/2"

140#

38CK

C036

XX

OO

22 1/

2"33

15/16

"3 3

/16"

3/4"

3 11/1

6"18

1/8"

8 1/8"

7/16"

2 3/4"

2 15/1

6"1/4

"11

3/4"

12 1/

8"15

"15

3#

38CK

C042

OX

OO

22 1/

2"33

15/16

"3 1

/4"7/8

"3 1

1/16"

18 1/

8"8 1

/8"7/1

6"2 3

/4"2 1

5/16"

1/4"

11 3/

4"12

1/8"

15"

175#

38CK

C048

CX

OO

30"

27 15

/16"

3 1/4"

7/8"

6 1/2"

23 1/

2"10

"7/1

6"2 3

/4"2 1

5/16"

1/4"

16"

14 1/

2"14

"21

5#

38CK

C060

CO

XO

O30

"39

15/16

"3 1

/4"7/8

"6 1

/2"23

1/2"

10"

7/16"

2 3/4"

2 15/1

6"1/4

"16

"14

1/2"

16"

220#

230-1-50

400-3-50

-

-

UNIT

SIZ

EMI

NIMU

MMO

UNTI

NG P

ADDI

MENS

IONS

1818

" X 18

"

24, 3

0, 36

, 42

22 1/

2" X

22 1/

2"

48, 6

030

" X 30

"

NOTE

S:1.

ALLO

W 30

" CLE

ARAN

CE T

O SE

RVIC

E SI

DE O

F UN

IT,

48"

ABO

VE U

NIT,

6" O

N SI

DE, 1

2" O

N RE

MAIN

ING

SIDE

, A

ND 24

" BET

WEE

N UN

ITS

FOR

PROP

ER A

IRFL

OW.

2. MI

NIMU

M OU

TDOO

R OP

ERAT

ING

AMBI

ENT

IN C

OOLIN

G M

ODE

IS 55

F, M

AX. 1

25F.

3. SE

RIES

DES

IGNA

TION

IS T

HE 13

TH P

OSIT

ION

OF T

HE U

NIT

MODE

L NUM

BER.

4. CE

NTER

OF

GRAV

ITY

.

X =

YES

O =

NO

FIEL

D PO

WER

SUP

PLY

CONN

.7/8

" HOL

E W

ITH

1 1/8"

KNO

CKOU

T

1 3/8"

KNO

CKOU

TAN

D

FIEL

D CO

NTRO

L SUP

PLY

CONN

.7/8

" HOL

E3/8

"LIQ

UID

LINE

CONN

.

AIR

IN

AIR

IN

AIR

IN

AIR

IN

AIR

DISC

HARG

E

AIR

DISC

HARG

EAI

RDI

SCHA

RGE

SQ.

3/8" T

IEDO

WN

KNOC

KOUT

S(2

) PLA

CES

VAP

OR LI

NE C

ONN.

D

X

38CKC

Page 8: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

8

DIM

EN

SIO

NS

(S.I

.)

EN

F

G_M

A

B

P

31.8

L

J

H

KC

73.02

UNIT

SERI

ESEL

ECTR

ICAL

CHAR

ACTE

RIST

ICS

AB

CD

EF

GH

JK

LM

NP

SHIP

PING

WEI

GHT

(kg)

38CK

C018

XO

OO

457.2

608.0

81.0

15.9

76.2

381.0

198.4

11.1

42.9

47.6

6.324

4.525

7.024

1.354

.5

38CK

C024

XO

OO

571.5

557.2

81.0

15.9

93.7

460.4

206.4

11.1

69.8

74.6

6.329

8.430

8.027

3.159

.4

38CK

C030

XO

OO

571.5

658.8

81.0

19.1

93.7

460.4

206.4

11.1

69.8

74.6

6.329

8.430

8.029

2.163

.6

38CK

C036

XX

OO

571.5

862.0

81.0

19.1

93.7

460.4

206.4

11.1

69.8

74.6

6.329

8.430

8.038

1.069

.4

38CK

C042

OX

OO

571.5

862.0

82.6

22.2

93.7

460.4

206.4

11.1

69.8

74.6

6.329

8.430

8.038

1.079

.5

38CK

C048

CX

OO

762.0

709.6

82.6

22.2

165.1

596.9

254.0

11.1

69.8

74.6

6.340

6.436

8.035

5.697

.5

38CK

C060

CO

XO

O76

2.010

14.4

82.6

22.2

165.1

596.9

254.0

11.1

69.8

74.6

6.340

6.436

8.040

6.499

.8

230-1-50

400-3-50

-

-

UNIT

SIZ

EMI

NIMU

MMO

UNTI

NG P

ADDI

MENS

IONS

1845

7.2 X

457.2

24, 3

0, 36

, 42

571.5

X 57

1.5

48, 6

076

2.0 X

762.0

NOTE

S:1.

ALLO

W 30

" CLE

ARAN

CE T

O SE

RVIC

E SI

DE O

F UN

IT,

48"

ABO

VE U

NIT,

6" O

N SI

DE, 1

2" O

N RE

MAIN

ING

SIDE

, A

ND 24

" BET

WEE

N UN

ITS

FOR

PROP

ER A

IRFL

OW.

2. MI

NIMU

M OU

TDOO

R OP

ERAT

ING

AMBI

ENT

IN C

OOLIN

G M

ODE

IS 55

F, M

AX. 1

25F.

3. SE

RIES

DES

IGNA

TION

IS T

HE 13

TH P

OSIT

ION

OF T

HE U

NIT

MODE

L NUM

BER.

4. CE

NTER

OF

GRAV

ITY

.

FIEL

D PO

WER

SUP

PLY

CONN

.22

.2 mm

HOL

E W

ITH

28.6

mm K

NOCK

OUT

34.9

mm K

NOCK

OUT

AND

FIEL

D CO

NTRO

L SUP

PLY

CONN

.22

.2 mm

HOL

E9.5

mm

LIQUI

D LIN

E CO

NN.

AIR

IN

AIR

IN

AIR

IN

AIR

IN

AIR

DISC

HARG

E

AIR

DISC

HARG

EAI

RDI

SCHA

RGE

SQ.

9.5 m

m TI

EDOW

N KN

OCKO

UTS

(2) P

LACE

S

VAP

OR LI

NE C

ONN.

D

X =

YES

O =

NO

X

38CKC

Page 9: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

9

ELECTRICAL DATAUNIT SIZE

---VOLTAGESERIES

V/PHOPERATINGVOLTS* COMPRESSOR FAN

FLA MCA

MIN WIRESIZE60C /75C**

MAXLENGTH(FT)‡

60C/75C

MAXLENGTH(m)‡

60C/75C

MAX FUSE{ ORBKR AMPS

MAX MIN LRA RLA

018---7D

230---1 253 207

55.0 9.9 0.80 13.2 14 59/56 18.0/17.1 20

024---7D 68.0 11.6 0.52 15.0 14 53/50 16.2/15.2 25

030---7D 75.1 12.1 0.52 15.6 14 49/47 14.9/14.3 25

036---7D 94.0 17.7 0.52 22.6 12 55/52 16.8/15.8 35

048---7C 150.0 25.8 1.60 33.6 10 91/87 27.7/26.5 50

036---9D

400---3 440 360

42.0 6.4 0.30 8.3 14 202/192 61.8/58.7 15

042---9D 58.0 7.1 0.70 9.6 14 202/192 61.8/58.7 15

048---9C 63.0 7.9 0.70 10.7 14 165/157 50.3/47.9 15

060---9C 74.0 9.0 0.70 11.9 14 152/144 46.4/44 20* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.{ Time---delay fuse.} Length shown is as measured 1 way along wire path between the unit and service panel for a voltage drop not to exceed 2%.** If wire is applied at ambient greater than 30° C (86° F), consult Table 310---16 of the NEC (NFPA 70).The ampacity of nonmetallic---sheathed cable (NM), trade name ROMEX, shall be that of 60° C (140° F) conductors, per the NEC (NFPA 70)Article 336---26. If other than uncoated (non---plated), 60 or 75° C (140 or 167° F) insulation, copper wire (solid wire for 10 AWG and smaller, strandedwire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70).

FLA --- Full Load AmpsLRA --- Locked Rotor AmpsMCA --- Minimum Circuit AmpsRLA --- Rated Load AmpsNOTES:1. Control circuit is 24v on all units and requires external power source.2. Copper wire must be used from service disconnect to unit.3. All motors/compressors contain internal overload protection.

COMBINATION RATINGS*Outdoor Unit Size---Voltage, Series Indoor Model

Nominal AirflowCooling @ 95°F (35°C) Cooling @ 115°F (46°C)

Capacity Power Efficiency Capacity PowerCFM L/s BTUH kW kW W/W EER BTUH kW kW

38CKC018---X---7D

FB4BSF018 600 283 18000 5.27 2.00 2.64 9.00 14600 4.28 2.25FB4BSF024 600 283 19000 5.57 2.11 2.64 9.00 15476 4.53 2.39F33QX018 562 265 19200 5.63 2.06 2.72 9.30 15622 4.58 2.32FS3QX024 651 307 20200 5.92 2.10 2.81 9.60 16352 4.79 2.36

38CKC024---X---7D

FB4BSF024 800 377 24000 7.03 2.67 2.64 9.00 19500 5.71 3.00FB4BSF030 800 377 24800 7.27 2.76 2.64 9.00 20085 5.88 2.09FS3QX024 651 307 23600 6.91 2.65 2.61 8.90 19111 5.60 2.97FS3QX030 848 400 25400 7.44 2.79 2.67 9.10 20670 6.06 3.15

38CKC030---X---7D

FB4BSF030 1000 472 29000 8.50 3.22 2.64 9.00 24400 7.15 3.59FB4BSF036 1000 472 29800 8.73 3.35 2.61 8.90 25132 7.36 3.73FS3QX030 937 442 28200 8.26 3.17 2.61 8.90 23668 6.93 3.52FS3QX036 1076 508 28800 8.44 3.39 2.49 8.50 24156 7.08 3.77

38CKC036---X---7D,9D

FB4BSF036 1200 566 35000 10.25 3.89 2.64 9.00 29100 8.53 4.28FB4BS(F,B)042 1200 566 35600 10.43 3.96 2.64 9.00 29682 8.70 4.37FS3QX036 1076 508 33000 9.67 3.75 2.58 8.80 27354 8.01 4.11FS3QX042 1126 531 34200 10.02 3.68 2.72 9.30 28518 8.36 4.07

38CKC042---X---9D

FB4BS(F,B)042 1400 660 39000 11.43 4.33 2.64 9.00 33400 9.79 5.14FB4BS(F,B)048 1400 660 40000 11.72 4.21 2.78 9.50 34402 10.08 5.29FS3QX042 1277 602 37200 10.90 3.84 2.84 9.70 32732 9.59 4.73FS3QX048 1477 697 38500 11.28 3.74 3.02 10.30 34736 10.18 4.63

38CKC048---X---7C,9C

FB4BS(F,B)048 1600 755 47000 13.77 5.22 2.64 9.00 44700 13.10 6.39FB4BS(F,B)060 1600 755 48500 14.21 5.39 2.64 9.00 46041 13.49 6.58FS3QX048 1477 697 46000 13.48 4.79 2.81 9.60 43806 12.84 5.88FS3QX060 1629 768 49000 14.36 5.05 2.84 9.70 46488 13.62 6.20

38CKC060---X---9CFB4BS(F,B)060 1850 873 60000 17.58 6.67 2.64 9.00 54300 15.91 7.76FB4BSB070 1850 873 61000 17.87 6.78 2.64 9.00 55386 16.23 7.92FS3QX060 2025 955 58500 17.14 6.16 2.78 9.50 55386 16.23 7.14

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included.Ratings are based on: Cooling Standard: 80° F (27° C) db 67° F (19° C) wb indoor entering air temperature and 95° F (35° C) db air entering outdoor unit.

EER --- Energy Efficiency RatiokW --- KilowattsBTUH --- BTU/Hr

38CKC

Page 10: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

10

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(EN

GL

ISH

)INDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC018---7DOUTDOORSECTIONWITHFB4BSF018INDOORSECTION

525

57 62 67 72

17.33

18.66

20.35

21.52

17.33

15.89

13.51

10.91

1.611.641.671.70

16.09

17.15

19.10

20.72

16.09

14.99

12.92

10.58

1.731.771.821.86

14.82

15.60

17.57

19.48

14.82

14.05

12.14

10.06

1.851.881.962.02

13.59

14.05

15.90

17.94

13.59

13.12

11.30

9.40

1.971.992.082.17

12.37

12.57

14.26

16.23

12.37

12.18

10.48

8.65

2.102.112.202.32

11.19

11.20

12.64

14.50

11.19

11.20

9.687.93

2.232.232.322.44

600

57 62 67 72

18.15

19.12

20.66

21.70

18.15

16.88

14.08

11.15

1.651.671.701.72

16.87

17.64

19.52

20.98

16.87

16.01

13.62

10.91

1.781.811.851.89

15.55

16.07

18.00

19.83

15.55

15.03

12.88

10.46

1.901.932.002.05

14.24

14.47

16.30

18.32

14.24

14.01

12.02

9.84

2.032.042.132.21

12.96

12.97

14.60

16.62

12.96

12.97

11.17

9.10

2.162.162.252.37

11.70

11.70

12.92

14.84

11.70

11.70

10.35

8.36

2.292.292.372.50

675

57 62 67 72

18.79

19.46

20.85

21.81

18.79

17.75

14.56

11.36

1.681.701.731.75

17.53

18.02

19.81

21.13

17.53

16.92

14.23

11.18

1.831.841.881.91

16.18

16.45

18.32

20.06

16.18

15.89

13.55

10.80

1.961.972.032.08

14.80

14.83

16.63

18.60

14.80

14.83

12.70

10.23

2.082.082.182.24

13.46

13.46

14.86

16.92

13.46

13.46

11.82

9.53

2.212.212.292.41

12.15

12.14

13.15

15.09

12.15

12.14

10.96

8.76

2.352.352.412.54

IndoorModel

Capacity

Power

*FB4BSF018

1.00

1.00

FB4BSF024

1.06

1.06

FS3QX018

1.07

1.03

FS3QX024

1.12

1.05

INDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC024---7DOUTDOORSECTIONWITHFB4BSF024INDOORSECTION

700

57 62 67 72

23.29

24.99

27.57

29.71

23.29

21.35

18.36

15.05

2.122.172.252.32

21.63

22.94

25.54

28.01

21.63

20.11

17.34

14.32

2.262.342.432.52

19.95

20.89

23.39

26.01

19.95

18.87

16.24

13.47

2.422.472.622.72

18.31

18.87

21.19

23.87

18.31

17.65

15.13

12.55

2.582.622.782.92

16.72

16.95

19.05

21.63

16.72

16.45

14.06

11.59

2.752.772.933.12

15.16

15.17

17.00

19.40

15.16

15.17

13.04

10.64

2.932.933.093.30

800

57 62 67 72

24.48

25.70

28.18

30.11

24.48

22.84

19.35

15.54

2.192.222.302.36

22.72

23.61

26.19

28.49

22.72

21.57

18.40

14.88

2.362.392.482.56

20.96

21.51

24.00

26.54

20.96

20.26

17.31

14.07

2.512.542.672.77

19.22

19.46

21.71

24.40

19.22

18.94

16.15

13.18

2.672.692.852.97

17.53

17.54

19.50

22.14

17.53

17.54

15.04

12.24

2.852.853.003.18

15.90

15.90

17.38

19.85

15.90

15.90

13.98

11.26

3.033.033.163.38

900

57 62 67 72

25.44

26.29

28.61

30.39

25.44

24.24

20.26

15.97

2.252.272.342.40

23.64

24.18

26.67

28.82

23.64

22.91

19.38

15.37

2.432.452.532.61

21.82

22.07

24.48

26.92

21.82

21.52

18.32

14.62

2.602.622.722.81

20.00

20.01

22.17

24.79

20.00

20.01

17.16

13.76

2.762.762.913.02

18.22

18.22

19.86

22.54

18.22

18.22

15.99

12.84

2.932.933.073.23

16.51

16.51

17.68

20.22

16.51

16.51

14.88

11.88

3.123.123.233.43

IndoorModel

Capacity

Power

*FB4BSF024

1.00

1.00

FB4BSF030

1.03

1.03

FS3QX024

0.98

0.99

FS3QX030

1.06

1.05

Seenotesonpage13

38CKC

Page 11: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

11

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(EN

GL

ISH

)C

ON

TIN

UE

DINDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC030---7DOUTDOORSECTIONWITHFB4BSF030INDOORSECTION

875

57 62 67 72

28.11

29.54

32.55

35.31

28.11

26.22

22.37

18.21

2.602.652.742.82

26.50

27.55

30.51

33.48

26.50

25.08

21.41

17.48

2.792.842.953.05

24.83

25.52

28.39

31.42

24.83

23.93

20.40

16.64

2.973.003.163.27

23.17

23.48

26.15

29.23

23.17

22.75

19.34

15.76

3.153.173.343.50

21.51

21.52

23.92

26.90

21.51

21.52

18.31

14.83

3.343.343.513.71

19.84

19.84

21.74

24.54

19.84

19.84

17.30

13.87

3.523.523.683.92

1000

57 62 67 72

29.43

30.32

33.22

35.81

29.43

28.08

23.68

18.89

2.682.712.792.87

27.73

28.30

31.17

34.03

27.73

26.91

22.76

18.23

2.892.913.013.10

26.01

26.27

29.00

31.98

26.01

25.66

21.76

17.44

3.083.103.223.34

24.23

24.24

26.70

29.77

24.23

24.24

20.68

16.57

3.263.263.433.56

22.48

22.47

24.40

27.40

22.48

22.47

19.61

15.65

3.453.453.593.78

20.73

20.73

22.16

25.00

20.73

20.73

18.57

14.71

3.643.643.763.99

1125

57 62 67 72

30.50

30.96

33.71

36.14

30.50

29.76

24.89

19.49

2.752.762.842.92

28.76

28.94

31.67

34.40

28.76

28.50

24.03

18.90

2.962.973.063.16

26.98

26.98

29.46

32.37

26.98

26.98

23.04

18.16

3.183.183.283.39

25.12

25.12

27.15

30.15

25.12

25.12

21.98

17.32

3.363.363.493.62

23.28

23.27

24.78

27.78

23.28

23.27

20.85

16.43

3.553.553.663.84

21.46

21.46

22.49

25.32

21.46

21.46

19.76

15.48

3.753.753.834.05

IndoorModel

Capacity

Power

*FB4BSF030

1.00

1.00

FB4BSF036

1.03

1.04

FS3QX030

0.97

0.98

FS3QX036

0.99

1.05

INDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC036---7D,9DOUTDOORSECTIONWITHFB4BSF036INDOORSECTION

1050

57 62 67 72

34.54

36.14

39.90

43.27

34.54

32.46

27.64

22.41

3.193.243.363.47

32.36

33.49

37.15

40.77

32.36

30.87

26.33

21.40

3.383.443.583.71

30.15

30.83

34.32

38.00

30.15

29.26

24.95

20.26

3.563.603.803.95

27.97

28.24

31.38

35.11

27.97

27.63

23.51

19.07

3.763.773.994.18

25.85

25.85

28.58

32.12

25.85

25.85

22.16

17.86

3.963.964.174.41

23.72

23.72

25.83

29.21

23.72

23.72

20.82

16.68

4.164.164.344.63

1200

57 62 67 72

36.09

37.07

40.67

43.81

36.09

34.71

29.25

23.21

3.303.333.453.55

33.80

34.38

37.90

41.37

33.80

33.05

27.96

22.28

3.523.543.673.80

31.48

31.68

35.00

38.60

31.48

31.25

26.59

21.20

3.713.723.894.04

29.17

29.16

31.99

35.69

29.17

29.16

25.13

20.03

3.903.904.104.27

26.93

26.92

29.10

32.65

26.93

26.92

23.71

18.83

4.114.114.284.50

24.70

24.69

26.28

29.67

24.70

24.69

22.32

17.63

4.324.324.464.72

1350

57 62 67 72

37.34

37.83

41.22

44.16

37.34

36.69

30.72

23.93

3.403.423.533.62

35.00

35.11

38.44

41.77

35.00

35.05

29.51

23.08

3.633.633.753.88

32.58

32.58

35.51

39.02

32.58

32.58

28.14

22.04

3.853.853.984.12

30.16

30.15

32.47

36.09

30.16

30.15

26.68

20.90

4.044.044.194.36

27.82

27.81

29.50

33.04

27.82

27.81

25.18

19.74

4.254.254.384.59

25.50

25.50

26.63

30.02

25.50

25.50

23.72

18.53

4.464.464.564.81

IndoorModel

Capacity

Power

*FB4BSF036

1.00

1.00

FB4BS(F,B)036

1.02

1.02

FS3QX036

0.94

0.96

FS3QX042

0.98

0.95

Seenotesonpage13

38CKC

Page 12: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

12

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(EN

GL

ISH

)C

ON

TIN

UE

DINDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC042---9DOUTDOORSECTIONWITHFB4BSF042INDOORSECTION

1225

57 62 67 72

38.28

39.51

43.15

46.71

38.28

36.24

30.58

24.56

3.323.353.453.55

36.35

37.25

40.83

44.54

36.35

34.85

29.46

23.68

3.703.743.843.94

34.27

34.83

38.28

42.09

34.27

33.36

28.23

22.69

4.084.114.254.35

32.14

32.37

35.56

39.38

32.14

31.78

26.90

21.60

4.494.504.654.77

29.96

29.96

32.86

36.55

29.96

29.96

25.59

20.46

4.914.915.055.19

27.73

27.73

30.04

33.67

27.73

27.73

24.23

19.30

5.305.305.425.60

1400

57 62 67 72

39.74

40.37

43.87

47.28

39.74

38.65

32.39

25.52

3.433.453.533.64

37.73

38.10

41.54

45.12

37.73

37.17

31.30

24.70

3.833.843.924.03

35.57

35.61

39.00

42.66

35.57

35.61

30.09

23.74

4.224.224.334.43

33.34

33.33

36.17

39.98

33.34

33.33

28.73

22.69

4.624.624.754.85

31.14

31.13

33.40

37.07

31.13

31.13

27.37

21.55

5.035.035.145.26

28.81

28.81

30.53

34.14

28.81

28.81

25.96

20.38

5.435.435.525.68

1575

57 62 67 72

40.92

41.12

44.39

47.68

40.92

40.68

34.07

26.39

3.533.533.613.72

38.89

38.91

42.05

45.51

38.89

38.91

33.03

25.63

3.933.934.004.11

36.68

36.67

39.49

43.06

36.68

36.67

31.83

24.71

4.344.344.414.51

34.39

34.38

36.65

40.39

34.39

34.38

30.48

23.69

4.744.744.824.93

32.10

32.09

33.81

37.44

32.10

32.09

29.05

22.58

5.145.145.235.34

29.70

29.69

30.90

34.48

29.70

29.69

27.58

21.41

5.545.545.615.75

IndoorModel

Capacity

Power

*FB4BS(F,B0042

1.00

1.00

FB4BS(F,B)048

1.03

0.97

FS3QX042

0.95

0.89

FS3QX048

0.99

0.86

INDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC048---7C,9COUTDOORSECTIONWITHFB4BSF048INDOORSECTION

1400

57 62 67 72

40.95

42.79

47.02

50.91

40.95

38.14

32.49

26.36

3.974.034.154.28

40.87

42.41

46.74

51.08

40.87

38.63

32.87

26.72

4.404.474.614.76

40.63

41.78

46.10

50.77

40.63

38.94

33.07

26.90

4.884.945.125.28

40.14

40.87

45.20

50.02

40.14

39.08

33.14

26.89

5.415.455.695.86

39.38

39.66

43.89

48.89

39.38

38.99

33.06

26.74

5.996.006.266.49

38.29

38.29

42.17

47.26

38.29

38.29

32.85

26.41

6.616.616.867.17

1600

57 62 67 72

42.73

43.75

47.90

51.59

42.73

40.63

34.37

27.35

4.094.124.254.37

42.65

43.47

47.67

51.85

42.65

41.35

34.90

27.85

4.554.584.714.85

42.37

42.83

47.00

51.61

42.37

41.65

35.21

28.15

5.045.075.225.38

41.86

41.88

46.06

50.86

41.86

41.88

35.38

28.22

5.585.585.795.96

41.05

41.04

44.70

49.70

41.05

41.04

35.34

28.14

6.166.166.396.59

39.91

39.91

42.93

48.04

39.91

39.91

35.17

27.87

6.796.796.997.27

1800

57 62 67 72

44.20

44.51

48.56

52.08

44.20

42.90

36.14

28.26

4.204.214.334.45

44.13

44.40

48.37

52.39

44.13

43.74

36.84

28.88

4.664.674.804.94

43.82

43.84

47.70

52.22

43.82

43.84

37.26

29.32

5.195.195.315.47

43.28

43.27

46.74

51.48

43.28

43.27

37.50

29.48

5.745.745.886.05

42.44

42.43

45.35

50.31

42.44

42.43

37.54

29.47

6.326.326.506.68

41.26

41.25

43.52

48.63

41.26

41.25

37.38

29.27

6.956.957.117.37

IndoorModel

Capacity

Power

*FB4BS(F,B0048

1.00

1.00

FB4BS(F,B)060

1.03

1.03

FS3QX048

0.98

0.92

FS3QX060

1.04

0.97

Seenotesonpage13

38CKC

Page 13: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

13

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(EN

GL

ISH

)C

ON

TIN

UE

DINDOOR

COILAIR

CONDENSERENTERINGAIRTEMPERATURES°F

7585

95105

115

125

CFM

(F)

EWB

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Capacity†

(MBtuh)

Total

Sys.

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC060---9COUTDOORSECTIONWITHFB4BSF060INDOORSECTION

1700

57 62 67 72

55.30

57.86

63.31

67.26

55.30

51.77

43.73

34.77

5.375.405.525.64

53.65

55.67

61.68

66.88

53.65

50.88

43.35

34.94

5.855.936.036.17

51.82

53.20

59.20

65.35

51.82

49.85

42.49

34.55

6.346.406.596.72

49.86

50.69

56.49

62.99

49.86

48.76

41.47

33.80

6.886.917.147.29

47.74

47.98

53.61

60.24

47.74

47.44

40.42

32.86

7.417.427.657.87

45.40

45.39

50.38

57.10

45.40

45.39

39.25

31.78

7.947.948.178.46

1850

57 62 67 72

56.88

58.75

63.82

67.59

56.88

54.01

45.08

35.40

5.465.495.605.74

55.19

56.59

62.42

67.37

55.19

53.18

44.97

35.75

5.996.036.126.26

53.27

54.10

60.00

65.95

53.27

52.11

44.24

35.49

6.486.516.676.81

51.31

51.61

57.23

63.70

51.31

50.91

43.24

34.86

7.007.027.247.37

49.14

49.13

54.30

60.93

49.14

49.13

42.20

33.95

7.547.547.767.95

46.73

46.73

51.02

57.77

46.73

46.73

41.02

32.90

8.078.078.278.54

2000

57 62 67 72

58.23

59.49

64.22

67.83

58.23

56.09

46.38

35.98

5.555.575.695.82

56.58

57.43

63.00

67.72

56.58

55.33

46.51

36.48

6.096.106.206.35

54.62

54.96

60.65

66.40

54.62

54.15

45.91

36.35

6.606.616.756.90

52.59

52.59

57.86

64.25

52.59

52.59

44.98

35.84

7.137.137.327.46

50.37

50.36

54.87

61.47

50.37

50.36

43.90

34.98

7.667.667.868.03

47.92

47.92

51.56

58.30

47.92

47.92

42.73

33.96

8.208.208.378.62

IndoorModel

Capacity

Power

*FB4BS(F,B0048

1.00

1.00

FB4BSF070

1.02

1.02

FS3QX060

0.98

0.92

NOTE:Whentherequireddatafallbetweenthepublisheddata,interpolationmaybeperformed.Extrapolationisnotanacceptablepractice.

DetailedcoolingcapacitiesarebasedonindoorandoutdoorunitatthesameelevationperARIstandard210/240---08.Ifadditionaltubinglengthand/orindoorunitislocatedaboveoutdoorunit,aslightvariationincapacitymay

occur.

*TestedCombination

{Totalandsensiblecapacitiesarenetcapacities.Blowermotorheathasbeensubtracted.

}Sensiblecapacitiesshownarebasedon80°F(27°C)enteringairattheindoorcoil.Forsensiblecapacitiesatotherthan80°F(27°C),deduct835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairforeachdegreebelow

80°F(27°C),oradd835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairperdegreeabove80°F(27°C).

**UnitTotalSystemkWistotalofindoorandoutdoorunitkilowatts.

EWB---EnteringWetBulb

38CKC

Page 14: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

14

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(S.I

.)EVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC018---7DOUTDOORSETIONWITHFB4BSF018INDOORSECTION

250

14 17 19 22

5.085.475.966.30

5.084.663.963.20

1.611.641.671.70

4.715.035.606.07

4.714.393.783.10

1.731.771.821.86

4.344.575.155.71

4.344.123.562.95

1.851.881.962.02

3.984.124.665.26

3.983.843.312.75

1.971.992.082.17

3.633.684.184.76

3.633.573.072.53

2.102.112.202.32

3.283.283.704.25

3.283.282.842.32

2.232.232.322.44

285

14 17 19 22

5.325.606.056.36

5.324.954.123.27

1.651.671.701.72

4.945.175.726.15

4.944.693.993.20

1.781.811.851.89

4.564.715.275.81

4.564.403.773.06

1.901.932.002.05

4.174.244.785.37

4.174.113.522.88

2.032.042.132.21

3.803.804.284.87

3.803.803.272.67

2.162.162.252.37

3.433.433.794.35

3.433.433.032.45

2.292.292.372.50

320

14 17 19 22

5.515.706.116.39

5.515.204.273.33

1.681.701.731.75

5.145.285.816.19

5.144.964.173.27

1.831.841.881.91

4.744.825.375.88

4.744.663.973.16

1.961.972.032.08

4.344.344.875.45

4.344.343.723.00

2.082.082.182.24

3.943.944.354.96

3.943.943.462.79

2.212.212.292.41

3.563.563.854.42

3.563.563.212.57

2.352.352.412.54

IndoorModel

Capacity

Power

*FB4BSF018

1.00

1.00

FB4BSF024

1.06

1.06

FS3QX018

1.07

1.03

FS3QX024

1.12

1.05

EVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC024---7DOUTDOORSETIONWITHFB4BSF024INDOORSECTION

330

14 17 19 22

6.827.328.088.70

6.826.265.384.41

2.122.172.252.32

6.346.727.488.21

6.345.895.084.20

2.262.342.432.52

5.856.126.857.62

5.855.534.763.95

2.422.472.622.72

5.365.536.216.99

5.365.174.433.68

2.582.622.782.92

4.904.975.586.34

4.904.824.123.40

2.752.772.933.12

4.444.444.985.68

4.444.443.823.12

2.932.933.093.30

380

14 17 19 22

7.177.538.268.82

7.176.695.674.55

2.192.222.302.36

6.666.927.678.35

6.666.325.394.36

2.362.392.482.56

6.146.307.037.78

6.145.945.074.12

2.512.542.672.77

5.635.706.367.15

5.635.554.733.86

2.672.692.852.97

5.145.145.716.49

5.145.144.413.59

2.852.853.003.18

4.664.665.095.82

4.664.664.103.30

3.033.033.163.38

425

14 17 19 22

7.457.708.388.90

7.457.105.944.68

2.252.272.342.40

6.937.097.818.44

6.936.715.684.50

2.432.452.532.61

6.396.477.177.89

6.396.305.374.28

2.602.622.722.81

5.865.866.497.26

5.865.865.034.03

2.762.762.913.02

5.345.345.826.60

5.345.344.693.76

2.932.933.073.23

4.844.845.185.93

4.844.844.363.48

3.123.123.233.43

IndoorModel

Capacity

Power

*FB4BSF024

1.00

1.00

FB4BSF030

1.03

1.03

FS3QX024

0.98

0.99

FS3QX030

1.06

1.05

Seenotesonpage17

38CKC

Page 15: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

15

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(S.I

.)C

ON

TIN

UE

DEVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC030---7DOUTDOORSETIONWITHFB4BSF030INDOORSECTION

415

14 17 19 22

8.248.669.54

10.34

8.247.686.555.33

2.602.652.742.82

7.768.078.949.81

7.767.356.275.12

2.792.842.953.05

7.287.488.329.21

7.287.015.984.88

2.973.003.163.27

6.796.887.668.56

6.796.675.674.62

3.153.173.343.50

6.306.307.017.88

6.306.305.364.34

3.343.343.513.71

5.815.816.377.19

5.815.815.074.06

3.523.523.683.92

470

14 17 19 22

8.628.889.73

10.49

8.628.236.945.53

2.682.712.792.87

8.138.299.139.97

8.137.886.675.34

2.892.913.013.10

7.627.708.509.37

7.627.526.385.11

3.083.103.223.34

7.107.107.828.72

7.107.106.064.86

3.263.263.433.56

6.596.587.158.03

6.596.585.754.59

3.453.453.593.78

6.076.076.497.32

6.076.075.444.31

3.643.643.763.99

530

14 17 19 22

8.949.079.88

10.59

8.948.727.295.71

2.752.762.842.92

8.438.489.28

10.08

8.438.357.045.54

2.962.973.063.16

7.907.918.639.49

7.907.916.755.32

3.183.183.283.39

7.367.367.968.83

7.367.366.445.07

3.363.363.493.62

6.826.827.268.14

6.826.826.114.81

3.553.553.663.84

6.296.296.597.42

6.296.295.794.53

3.753.753.834.05

IndoorModel

Capacity

Power

*FB4BSF030

1.00

1.00

FB4BSF036

1.03

1.04

FS3QX030

0.97

0.98

FS3QX036

0.99

1.05

EVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC036---7D,9DOUTDOORSETIONWITHFB4BSF036INDOORSECTION

495

14 17 19 22

10.12

10.59

11.69

12.68

10.12

9.518.106.57

3.193.243.363.47

9.489.81

10.88

11.94

9.489.047.716.27

3.383.443.583.71

8.839.03

10.06

11.13

8.838.577.315.94

3.563.603.803.95

8.208.279.19

10.29

8.208.106.895.59

3.763.773.994.18

7.577.578.389.41

7.577.576.495.23

3.963.964.174.41

6.956.957.578.56

6.956.956.104.89

4.164.164.344.63

565

14 17 19 22

10.57

10.86

11.92

12.84

10.57

10.17

8.576.80

3.303.333.453.55

9.90

10.07

11.10

12.12

9.909.688.196.53

3.523.543.673.80

9.229.28

10.25

11.31

9.229.167.796.21

3.713.723.894.04

8.558.549.37

10.46

8.558.547.365.87

3.903.904.104.27

7.897.898.539.57

7.897.896.955.52

4.114.114.284.50

7.247.247.708.69

7.247.246.545.16

4.324.324.464.72

635

14 17 19 22

10.94

11.08

12.08

12.94

10.94

10.75

9.007.01

3.403.423.533.62

10.25

10.29

11.26

12.24

10.25

10.27

8.656.76

3.633.633.753.88

9.559.54

10.40

11.43

9.559.548.246.46

3.853.853.984.12

8.848.849.51

10.57

8.848.847.826.12

4.044.044.194.36

8.158.158.649.68

8.158.157.385.78

4.254.254.384.59

7.477.477.808.80

7.477.476.955.43

4.464.464.564.81

IndoorModel

Capacity

Power

*FB4BSF036

1.00

1.00

FB4BS(F,B)036

1.02

1.02

FS3QX036

0.94

0.96

FS3QX042

0.98

0.95

Seenotesonpage17

38CKC

Page 16: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

16

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(S.I

.)C

ON

TIN

UE

DEVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC042---9DOUTDOORSETIONWITHFB4BSF042INDOORSECTION

580

14 17 19 22

11.22

11.58

12.64

13.69

11.22

10.62

8.967.20

3.323.353.453.55

10.65

10.91

11.96

13.05

10.65

10.21

8.636.94

3.703.743.843.94

10.04

10.21

11.22

12.33

10.04

9.788.276.65

4.084.114.254.35

9.429.48

10.42

11.54

9.429.317.886.33

4.494.504.654.77

8.788.789.63

10.71

8.788.787.505.99

4.914.915.055.19

8.138.128.809.86

8.138.127.105.65

5.305.305.425.60

660

14 17 19 22

11.64

11.83

12.86

13.85

11.64

11.32

9.497.48

3.433.453.533.64

11.06

11.16

12.17

13.22

11.06

10.89

9.177.24

3.833.843.924.03

10.42

10.43

11.43

12.50

10.42

10.43

8.826.96

4.224.224.334.43

9.779.77

10.60

11.71

9.779.778.426.65

4.624.624.754.85

9.129.129.79

10.86

9.129.128.026.31

5.035.035.145.26

8.448.448.94

10.00

8.448.447.615.97

5.435.435.525.68

745

14 17 19 22

11.99

12.05

13.01

13.97

11.99

11.92

9.987.73

3.533.533.613.72

11.40

11.40

12.32

13.34

11.40

11.40

9.687.51

3.933.934.004.11

10.75

10.75

11.57

12.62

10.75

10.75

9.337.24

4.344.344.414.51

10.08

10.07

10.74

11.84

10.08

10.07

8.936.94

4.744.744.824.93

9.409.409.91

10.97

9.409.408.516.62

5.145.145.235.34

8.708.709.05

10.10

8.708.708.086.27

5.545.545.615.75

IndoorModel

Capacity

Power

*FB4BS(F,B0042

1.00

1.00

FB4BS(F,B)048

1.03

0.97

FS3QX042

0.95

0.89

FS3QX048

0.99

0.86

EVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC048---7C,9COUTDOORSETIONWITHFB4BSF048INDOORSECTION

660

14 17 19 22

12.00

12.54

13.78

14.92

12.00

11.17

9.527.72

3.974.034.154.28

11.97

12.43

13.70

14.97

11.97

11.32

9.637.83

4.404.474.614.76

11.90

12.24

13.51

14.88

11.90

11.41

9.697.88

4.884.945.125.28

11.76

11.98

13.24

14.66

11.76

11.45

9.717.88

5.415.455.695.86

11.54

11.62

12.86

14.32

11.54

11.43

9.697.83

5.996.006.266.49

11.22

11.22

12.36

13.85

11.22

11.22

9.627.74

6.616.616.867.17

755

14 17 19 22

12.52

12.82

14.04

15.12

12.52

11.91

10.07

8.01

4.094.124.254.37

12.50

12.74

13.97

15.19

12.50

12.12

10.23

8.16

4.554.584.714.85

12.41

12.55

13.77

15.12

12.41

12.20

10.32

8.25

5.045.075.225.38

12.26

12.27

13.50

14.90

12.26

12.27

10.37

8.27

5.585.585.795.96

12.03

12.03

13.10

14.56

12.03

12.03

10.35

8.24

6.166.166.396.59

11.69

11.69

12.58

14.08

11.69

11.69

10.30

8.17

6.796.796.997.27

850

14 17 19 22

12.95

13.04

14.23

15.26

12.95

12.57

10.59

8.28

4.204.214.334.45

12.93

13.01

14.17

15.35

12.93

12.82

10.79

8.46

4.664.674.804.94

12.84

12.84

13.97

15.30

12.84

12.84

10.92

8.59

5.195.195.315.47

12.68

12.68

13.69

15.08

12.68

12.68

10.99

8.64

5.745.745.886.05

12.43

12.43

13.29

14.74

12.43

12.43

11.00

8.63

6.326.326.506.68

12.09

12.09

12.75

14.25

12.09

12.09

10.95

8.58

6.956.957.117.37

IndoorModel

Capacity

Power

*FB4BS(F,B0048

1.00

1.00

FB4BS(F,B)060

1.03

1.03

FS3QX048

0.98

0.92

FS3QX060

1.04

0.97

Seenotesonpage17

38CKC

Page 17: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

17

DE

TA

ILE

DC

OO

LIN

GC

APA

CIT

IES

(S.I

.)C

ON

TIN

UE

DEVAPAIR

CONDENSERENTERINGAIRTEMPERATURES°C

2429

3541

4652

L/S

(C)

EWB

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Capacity†(kW)

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38CKC060---9COUTDOORSETIONWITHFB4BSF060INDOORSECTION

800

14 17 19 22

16.20

16.95

18.55

19.71

16.20

15.17

12.81

10.19

5.375.405.525.64

15.72

16.31

18.07

19.60

15.72

14.91

12.70

10.24

5.855.936.036.17

15.18

15.59

17.35

19.15

15.18

14.61

12.45

10.12

6.346.406.596.72

14.61

14.85

16.55

18.46

14.61

14.29

12.15

9.90

6.886.917.147.29

13.99

14.06

15.71

17.65

13.99

13.90

11.84

9.63

7.417.427.657.87

13.30

13.30

14.76

16.73

13.30

13.30

11.50

9.31

7.947.948.178.46

875

14 17 19 22

16.67

17.21

18.70

19.81

16.67

15.83

13.21

10.37

5.465.495.605.74

16.17

16.58

18.29

19.74

16.17

15.58

13.18

10.47

5.996.036.126.26

15.61

15.85

17.58

19.32

15.61

15.27

12.96

10.40

6.486.516.676.81

15.03

15.12

16.77

18.66

15.03

14.92

12.67

10.21

7.007.027.247.37

14.40

14.40

15.91

17.85

14.40

14.40

12.36

9.95

7.547.547.767.95

13.69

13.69

14.95

16.93

13.69

13.69

12.02

9.64

8.078.078.278.54

945

14 17 19 22

17.06

17.43

18.82

19.87

17.06

16.43

13.59

10.54

5.555.575.695.82

16.58

16.83

18.46

19.84

16.58

16.21

13.63

10.69

6.096.106.206.35

16.00

16.10

17.77

19.45

16.00

15.87

13.45

10.65

6.606.616.756.90

15.41

15.41

16.95

18.82

15.41

15.41

13.18

10.50

7.137.137.327.46

14.76

14.76

16.08

18.01

14.76

14.76

12.86

10.25

7.667.667.868.03

14.04

14.04

15.11

17.08

14.04

14.04

12.52

9.95

8.208.208.378.62

IndoorModel

Capacity

Power

*FB4BS(F,B0048

1.00

1.00

FB4BSF070

1.02

1.02

FS3QX060

0.98

0.92

NOTE:Whentherequireddatafallbetweenthepublisheddata,interpolationmaybeperformed.Extrapolationisnotanacceptablepractice.

DetailedcoolingcapacitiesarebasedonindoorandoutdoorunitatthesameelevationperARIstandard210/240---08.Ifadditionaltubinglengthand/orindoorunitislocatedaboveoutdoorunit,aslightvariationincapacitymay

occur.

*Testedcombination

{Totalandsensiblecapacitiesarenetcapacities.Blowermotorheathasbeensubtracted.

}Sensiblecapacitiesshownarebasedon80°F(27°C)enteringairattheindoorcoil.Forsensiblecapacitiesatotherthan80°F(27°C),deduct835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairforeachdegreebelow

80°F(27°C),oradd835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairperdegreeabove80°F(27°C).

**UnitSystemPowerkWistotalofindoorandoutdoorunitkilowatts.

EWB---EnteringWetBulb

38CKC

Page 18: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

18

CONDENSER ONLY RATINGS (ENGLISH)

SST ° FCONDENSER ENTERING AIR TEMPERATURES ° F

55 65 75 85 95 105 115 12538CKC018---7D

30TCGSDTKW

18.6080.801.29

16.7089.701.38

15.1098.201.42

13.50106.101.47

11.90113.901.51

10.40121.901.53

8.80129.801.54

7.10137.601.53

35TCGSDTKW

21.3082.701.32

19.1091.501.41

17.20100.101.50

15.50108.501.54

13.80116.401.59

12.10124.201.62

10.50132.101.64

8.80139.901.64

40TCGSDTKW

24.6084.601.34

21.9093.501.45

19.70102.101.54

17.70110.401.63

15.90118.701.67

14.10126.701.71

12.30134.501.74

10.50142.401.76

45TCGSDTKW

28.8086.101.36

25.1095.501.48

22.50104.201.59

20.20112.501.68

18.20120.701.77

16.20128.901.80

14.30137.001.84

12.40144.801.87

50TCGSDTKW

34.4087.301.36

29.2097.301.51

25.80106.301.63

23.10114.701.74

20.80122.901.83

18.70131.001.92

16.60139.001.95

14.50147.001.98

55TCGSDTKW

39.9089.701.38

34.3099.001.53

29.70108.301.67

26.50116.901.79

23.80125.101.90

21.40133.201.99

19.10141.202.07

16.90149.002.12

38CKC024---7D

30TCGSDTKW

25.0087.501.66

22.8095.001.74

20.60102.401.80

18.40109.901.86

16.20117.501.91

14.00125.201.95

11.90132.901.97

9.60140.501.97

35TCGSDTKW

28.3090.401.73

25.8098.101.84

23.50105.501.93

21.20112.901.99

18.90120.402.05

16.60128.102.09

14.30135.802.13

12.00143.402.15

40TCGSDTKW

32.1093.101.79

29.20101.101.92

26.60108.802.04

24.10116.202.14

21.70123.602.19

19.20131.002.25

16.90138.702.30

14.50146.302.33

45TCGSDTKW

36.5095.901.86

33.10103.902.00

30.10111.702.14

27.40119.402.26

24.70127.002.37

22.10134.302.42

19.60141.802.47

17.10149.402.52

50TCGSDTKW

41.7098.601.92

37.70106.702.08

34.30114.502.23

31.10122.202.37

28.20129.902.49

25.30137.502.60

22.50145.102.67

19.90152.702.73

55TCGSDTKW

47.80101.301.98

43.00109.502.16

39.00117.502.33

35.50125.102.48

32.20132.802.62

29.10140.402.74

26.00147.902.86

23.10155.502.96

38CKC030---7D

30TCGSDTKW

28.4083.401.88

26.2091.702.00

24.00100.102.12

21.70108.502.23

19.30116.802.32

17.10125.202.39

14.70133.302.44

12.10141.302.46

35TCGSDTKW

31.8086.101.96

29.4094.402.11

27.10102.802.23

24.70111.002.35

22.20119.302.46

19.80127.702.55

17.40135.902.62

14.80144.002.66

40TCGSDTKW

35.4089.102.03

32.9097.302.20

30.40105.602.37

27.90113.902.49

25.30122.102.60

22.70130.302.71

20.20138.602.80

17.60146.702.86

45TCGSDTKW

39.3092.302.11

36.70100.502.30

34.00108.602.47

31.30116.902.64

28.60125.102.79

25.90133.202.88

23.20141.402.99

20.50149.503.07

50TCGSDTKW

43.7095.802.19

40.70103.802.39

37.80111.902.58

35.00120.102.76

32.10128.202.94

29.20136.303.10

26.40144.403.20

23.60152.503.30

55TCGSDTKW

48.8098.802.26

45.20107.402.49

42.00115.502.69

38.90123.502.89

35.90131.603.08

32.90139.703.25

29.70147.603.41

26.80155.703.56

KW --- Total Power (kW)SDT --- Saturated Temperature Leaving Compressor (° F)SST --- Saturated Temperature Entering Compressor (° F)TCG --- Gross Cooling Capacity (1000 Btuh)

38CKC

Page 19: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

19

CONDENSER ONLY RATINGS (ENGLISH) (CONT.)

SST ° FCONDENSER ENTERING AIR TEMPERATURES ° F

55 65 75 85 95 105 115 12538CKC036---7D, 9D

30TCGSDTKW

35.6085.702.34

32.7093.602.46

29.80101.602.58

26.90109.602.68

24.00117.702.77

21.10125.902.84

18.20133.902.89

15.20141.902.92

35TCGSDTKW

39.9088.702.45

36.8096.602.62

33.80104.602.74

30.70112.502.85

27.60120.502.96

24.60128.603.05

21.60136.703.12

18.50144.703.17

40TCGSDTKW

44.5092.102.56

41.2099.902.75

38.00107.702.93

34.80115.703.06

31.50123.503.16

28.30131.603.27

25.20139.603.36

22.00147.603.43

45TCGSDTKW

49.8095.202.66

46.00103.302.88

42.50111.103.07

39.10119.003.25

35.60126.903.41

32.20134.703.51

28.90142.803.62

25.60150.703.71

50TCGSDTKW

56.2097.702.75

51.60106.303.00

47.40114.603.23

43.70122.503.43

40.10130.403.61

36.40138.103.78

32.90146.103.92

29.40154.004.03

55TCGSDTKW

63.60100.302.83

58.30109.003.11

53.60117.303.36

49.30125.503.59

45.20133.503.80

41.30141.503.99

37.20149.404.17

33.60157.304.33

38CKC042---9D

30TCGSDTKW

36.4082.701.87

34.6092.102.20

32.60101.002.54

30.40110.202.92

28.10119.403.33

25.60128.603.76

22.90137.604.18

19.80146.404.57

35TCGSDTKW

40.0085.201.98

38.1094.202.29

36.00103.402.64

33.70112.503.02

31.20121.603.44

28.70130.803.88

25.90139.904.32

22.70148.604.73

40TCGSDTKW

43.9087.702.07

41.8096.802.41

39.60105.902.78

37.20115.003.17

34.60124.003.57

31.90133.204.01

29.00142.204.46

25.80151.004.90

45TCGSDTKW

48.4090.102.17

45.9099.402.52

43.40108.602.91

40.90117.703.33

38.10126.703.74

35.30135.704.18

32.40144.604.63

29.20153.205.08

50TCGSDTKW

53.4092.102.25

50.60101.502.61

47.90110.603.00

45.10119.703.42

42.30128.703.87

39.20137.604.35

36.20146.304.82

33.00154.905.27

55TCGSDTKW

59.1094.202.35

55.90103.602.71

52.90112.703.10

49.90121.703.52

46.90130.603.97

43.60139.504.44

40.30148.204.94

37.00156.705.45

38CKC048---7C 9C

30TCGSDTKW

46.0081.702.66

43.4090.602.95

40.6099.603.28

37.70108.603.64

34.80117.704.04

31.60126.804.46

28.10135.804.89

24.30144.605.32

35TCGSDTKW

50.9084.102.79

48.1093.003.10

45.20101.903.42

42.20110.803.79

39.20120.004.20

35.90129.104.64

32.40138.105.09

28.50146.905.55

40TCGSDTKW

56.2086.602.90

53.3095.403.23

50.20104.403.61

47.00113.303.98

43.80122.404.40

40.50131.504.85

36.90140.505.31

32.90149.305.79

45TCGSDTKW

62.1089.503.04

58.8098.203.38

55.60107.003.75

52.10115.804.16

48.70124.904.63

45.20134.105.11

41.50143.105.59

37.50152.006.08

50TCGSDTKW

68.4092.603.19

64.90101.203.53

61.40109.903.91

57.80118.804.34

53.90127.604.80

50.30136.705.32

46.50145.805.88

42.40154.706.44

55TCGSDTKW

75.8095.203.32

71.60104.203.69

67.70113.104.09

63.80121.804.52

59.80130.604.99

55.80139.605.52

51.90148.506.08

47.80157.206.67

KW --- Total Power (kW)SDT --- Saturated Temperature Leaving Compressor (° F)SST --- Saturated Temperature Entering Compressor (° F)TCG --- Gross Cooling Capacity (1000 Btuh)

38CKC

Page 20: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

20

CONDENSER ONLY RATINGS (ENGLISH) (CONT.)

SST ° FCONDENSER ENTERING AIR TEMPERATURES ° F

55 65 75 85 95 105 115 12538CKC060---9C

30TCGSDTKW

58.8082.903.29

55.5092.203.79

52.00101.004.25

48.30109.804.77

44.40118.705.34

40.30127.505.93

35.80136.206.51

30.80144.707.07

35TCGSDTKW

65.8084.403.34

61.7094.403.90

58.00103.604.44

54.10112.304.95

50.10121.105.54

45.90129.906.16

41.30138.706.78

36.30147.307.40

40TCGSDTKW

73.9085.903.39

68.9096.003.97

64.60105.604.57

60.20114.905.19

56.00123.605.76

51.70132.506.41

47.00141.307.07

42.00149.907.74

45TCGSDTKW

83.7087.203.43

81.9095.703.91

72.10107.304.66

67.50116.605.31

62.70125.706.01

58.20134.506.68

53.50143.307.37

48.40151.908.06

50TCGSDTKW

95.9088.303.46

87.0099.304.10

80.90109.104.74

75.60118.405.41

70.40127.506.12

65.40136.406.87

60.60145.107.65

55.40153.708.46

55TCGSDTKW

119.2087.303.37

98.60100.704.15

91.00110.804.82

84.90120.205.51

79.40129.306.23

73.50138.207.00

68.40146.907.80

63.10155.508.64

KW --- Total Power (kW)SDT --- Saturated Temperature Leaving Compressor (° F)SST --- Saturated Temperature Entering Compressor (° F)TCG --- Gross Cooling Capacity (1000 Btuh)

38CKC

Page 21: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

21

CONDENSER ONLY RATINGS (S.I.)SST°C

CONDENSER ENTERING AIR TEMPERATURES °C13 18 24 29 35 41 46 52

38CKC018---7D

---1TCGSDTKW

5.4027.001.29

4.9032.001.38

4.4037.001.42

4.0041.001.47

3.5046.001.51

3.0050.001.53

2.6054.001.54

2.1059.001.53

2TCGSDTKW

6.3028.001.32

5.6033.001.41

5.0038.001.50

4.5042.001.54

4.1047.001.59

3.6051.001.62

3.1056.001.64

2.6060.001.64

4TCGSDTKW

7.2029.001.34

6.4034.001.45

5.8039.001.54

5.2044.001.63

4.7048.001.67

4.1053.001.71

3.6057.001.74

3.1061.001.76

7TCGSDTKW

8.4030.001.36

7.4035.001.48

6.6040.001.59

5.9045.001.68

5.3049.001.77

4.8054.001.80

4.2058.001.84

3.6063.001.87

10TCGSDTKW

10.1031.001.36

8.5036.001.51

7.5041.001.63

6.8046.001.74

6.1050.001.83

5.5055.001.92

4.9059.001.95

4.2064.001.98

13TCGSDTKW

11.7032.001.38

10.0037.001.53

8.7042.001.67

7.8047.001.79

7.0052.001.90

6.3056.001.99

5.6061.002.07

4.9065.002.12

38CKC024---7D

---1TCGSDTKW

7.3031.001.66

6.7035.001.74

6.0039.001.80

5.4043.001.86

4.7047.001.91

4.1052.001.95

3.5056.001.97

2.8060.001.97

2TCGSDTKW

8.3032.001.73

7.6037.001.84

6.9041.001.93

6.2045.001.99

5.5049.002.05

4.9053.002.09

4.2058.002.13

3.5062.002.15

4TCGSDTKW

9.4034.001.79

8.6038.001.92

7.8043.002.04

7.1047.002.14

6.4051.002.19

5.6055.002.25

4.9059.002.30

4.2064.002.33

7TCGSDTKW

10.7035.001.86

9.7040.002.00

8.8044.002.14

8.0049.002.26

7.2053.002.37

6.5057.002.42

5.7061.002.47

5.0065.002.52

10TCGSDTKW

12.2037.001.92

11.0042.002.08

10.0046.002.23

9.1050.002.37

8.3054.002.49

7.4059.002.60

6.6063.002.67

5.8067.002.73

13TCGSDTKW

14.0038.001.98

12.6043.002.16

11.4047.002.33

10.4052.002.48

9.4056.002.62

8.5060.002.74

7.6064.002.86

6.8069.002.96

38CKC030---7D

---1TCGSDTKW

8.3029.001.88

7.7033.002.00

7.0038.002.12

6.4042.002.23

5.7047.002.32

5.0052.002.39

4.3056.002.44

3.5061.002.46

2TCGSDTKW

9.3030.001.96

8.6035.002.11

7.9039.002.23

7.2044.002.35

6.5049.002.46

5.8053.002.55

5.1058.002.62

4.3062.002.66

4TCGSDTKW

10.4032.002.03

9.6036.002.20

8.9041.002.37

8.2045.002.49

7.4050.002.60

6.7055.002.71

5.9059.002.80

5.1064.002.86

7TCGSDTKW

11.5034.002.11

10.7038.002.30

10.0043.002.47

9.2047.002.64

8.4052.002.79

7.6056.002.88

6.8061.002.99

6.0065.003.07

10TCGSDTKW

12.8035.002.19

11.9040.002.39

11.1044.002.58

10.2049.002.76

9.4053.002.94

8.6058.003.10

7.7062.003.20

6.9067.003.30

13TCGSDTKW

14.3037.002.26

13.2042.002.49

12.3046.002.69

11.4051.002.89

10.5055.003.08

9.6060.003.25

8.7064.003.41

7.8069.003.56

KW --- Total Power (kW)SDT --- Saturated Temperature Leaving Compressor (° C)SST --- Saturated Temperature Entering Compressor (° C)TCG --- Gross Cooling Capacity (1000 kW)

38CKC

Page 22: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

22

CONDENSER ONLY RATINGS (S.I.) (CONT.)

SST °CCONDENSER ENTERING AIR TEMPERATURES °C

13 18 24 29 35 41 46 5238CKC036---7D, 9D

---1TCGSDTKW

10.4030.002.34

9.6034.002.46

8.7039.002.58

7.9043.002.68

7.0048.002.77

6.2052.002.84

5.3057.002.89

4.5061.002.92

2TCGSDTKW

11.7032.002.45

10.8036.002.62

9.9040.002.74

9.0045.002.85

8.1049.002.96

7.2054.003.05

6.3058.003.12

5.4063.003.17

4TCGSDTKW

13.0033.002.56

12.1038.002.75

11.1042.002.93

10.2046.003.06

9.2051.003.16

8.3055.003.27

7.4060.003.36

6.4064.003.43

7TCGSDTKW

14.6035.002.66

13.5040.002.88

12.5044.003.07

11.4048.003.25

10.4053.003.41

9.4057.003.51

8.5062.003.62

7.5066.003.71

10TCGSDTKW

16.5037.002.75

15.1041.003.00

13.9046.003.23

12.8050.003.43

11.7055.003.61

10.7059.003.78

9.6063.003.92

8.6068.004.03

13TCGSDTKW

18.6038.002.83

17.1043.003.11

15.7047.003.36

14.4052.003.59

13.2056.003.80

12.1061.003.99

10.9065.004.17

9.8070.004.33

38CKC042---9D

---1TCGSDTKW

10.7028.001.87

10.1033.002.20

9.5038.002.54

8.9043.002.92

8.2049.003.33

7.5054.003.76

6.7059.004.18

5.8064.004.57

2TCGSDTKW

11.7030.001.98

11.2035.002.29

10.5040.002.64

9.9045.003.02

9.1050.003.44

8.4055.003.88

7.6060.004.32

6.7065.004.73

4TCGSDTKW

12.9031.002.07

12.2036.002.41

11.6041.002.78

10.9046.003.17

10.1051.003.57

9.3056.004.01

8.5061.004.46

7.6066.004.90

7TCGSDTKW

14.2032.002.17

13.4037.002.52

12.7043.002.91

12.0048.003.33

11.2053.003.74

10.3058.004.18

9.5063.004.63

8.6067.005.08

10TCGSDTKW

15.6033.002.25

14.8039.002.61

14.0044.003.00

13.2049.003.42

12.4054.003.87

11.5059.004.35

10.6064.004.82

9.7068.005.27

13TCGSDTKW

17.3035.002.35

16.4040.002.71

15.5045.003.10

14.6050.003.52

13.7055.003.97

12.8060.004.44

11.8065.004.94

10.9069.005.45

38CKC048---7C 9C

---1TCGSDTKW

13.5028.002.66

12.7033.002.95

11.9038.003.28

11.1043.003.64

10.2048.004.04

9.3053.004.46

8.2058.004.89

7.1063.005.32

2TCGSDTKW

14.9029.002.79

14.1034.003.10

13.3039.003.42

12.4044.003.79

11.5049.004.20

10.5054.004.64

9.5059.005.09

8.4064.005.55

4TCGSDTKW

16.5030.002.90

15.6035.003.23

14.7040.003.61

13.8045.003.98

12.8050.004.40

11.9055.004.85

10.8060.005.31

9.7065.005.79

7TCGSDTKW

18.2032.003.04

17.2037.003.38

16.3042.003.75

15.3047.004.16

14.3052.004.63

13.3057.005.11

12.2062.005.59

11.0067.006.08

10TCGSDTKW

20.0034.003.19

19.0038.003.53

18.0043.003.91

16.9048.004.34

15.8053.004.80

14.7058.005.32

13.6063.005.88

12.4068.006.44

13TCGSDTKW

22.2035.003.32

21.0040.003.69

19.8045.004.09

18.7050.004.52

17.5055.004.99

16.3060.005.52

15.2065.006.08

14.0070.006.67

KW --- Total Power (kW)SDT --- Saturated Temperature Leaving Compressor (° C)SST --- Saturated Temperature Entering Compressor (° C)TCG --- Gross Cooling Capacity (1000 kW)

38CKC

Page 23: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

23

CONDENSER ONLY RATINGS (S.I.) (CONT.)

SST °CCONDENSER ENTERING AIR TEMPERATURES °C

13 18 24 29 35 41 46 5238CKC060---9C

---1TCGSDTKW

17.2028.003.29

16.3033.003.79

15.2038.004.25

14.1043.004.77

13.0048.005.34

11.8053.005.93

10.5058.006.51

9.0063.007.07

2TCGSDTKW

19.3029.003.34

18.1035.003.90

17.0040.004.44

15.8045.004.95

14.7049.005.54

13.4054.006.16

12.1059.006.78

10.6064.007.40

4TCGSDTKW

21.7030.003.39

20.2036.003.97

18.9041.004.57

17.7046.005.19

16.4051.005.76

15.1056.006.41

13.8061.007.07

12.3066.007.74

7TCGSDTKW

24.5031.003.43

24.0035.003.91

21.1042.004.66

19.8047.005.31

18.4052.006.01

17.1057.006.68

15.7062.007.37

14.2067.008.06

10TCGSDTKW

28.1031.003.46

25.5037.004.10

23.7043.004.74

22.1048.005.41

20.6053.006.12

19.2058.006.87

17.8063.007.65

16.2068.008.46

13TCGSDTKW

34.9031.003.37

28.9038.004.15

26.7044.004.82

24.9049.005.51

23.3054.006.23

21.5059.007.00

20.1064.007.80

18.5069.008.64

KW --- Total Power (kW)SDT --- Saturated Temperature Leaving Compressor (° C)SST --- Saturated Temperature Entering Compressor (° C)TCG --- Gross Cooling Capacity (1000 kW)

SYSTEM DESIGN1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.

2. Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C).

3. Maximum outdoor operating air temperature is 125_F (51.7_C).

4. For reliable operation, unit should be level in all horizontal planes.

5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft (15.24m), indoor coil below = 150ft (45.7m).

6. For interconnecting refrigerant tube lengths between 50 (15.24m) and 175 (53.34m) or 20 ft (6.1m) vertical differential, consultResidential’s Split System Long--Line Application Guideline available from equipment distributor.

7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft (15.24m).

8. If any refrigerant tubing is buried, provide a 6 in. (152mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths upto 36 in. (912mm) may be buried without further consideration. For buried lines longer than 3 ft (912mm), consult your local distributor.

9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.

38CKC

Page 24: Product Data - CICLOPE · permanent--split--capacitor--type motor is designed for optimum efficiency. The motor is tested and qualified under extreme conditions to ensure the greatest

24

GUIDE SPECIFICATIONSGENERAL

AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER38CKC

1--1/2 TO 5 NOMINAL TONS (5.2 TO 17.5 kW)

System DescriptionOutdoor--mounted, air--cooled, split--system air conditioner unitsuitable for ground or rooftop installation. Unit consists of ahermetic compressor, an air--cooled coil, propeller--type condenserfan, and a control box. Unit will discharge supply air upward asshown on contract drawings. Unit will be used in a refrigerationcircuit to match up to a packaged fan coil or coil unit.

Quality Assurance— Unit construction will comply with latest edition of

ANSI/ASHRAE and with NEC.

— Unit will be constructed in accordance with ULstandards and will carry the UL label of approval. Unitwill have c--UL approval.

— Unit cabinet will be capable of withstanding Federal TestMethod Standard No. 141 (Method 6061) 500--hr saltspray test.

— Air--cooled condenser coils will be leak tested at 150psig and pressure tested at 300 psig.

— Unit constructed in ISO 9001 approved facility.

Delivery, Storage, and Handling— Unit will be shipped as single package only and is stored

and handled per unit manufacturer’s recommendations.

PRODUCTSEquipment

— Factory--assembled, single--piece, air--cooled airconditioner unit. Contained within the unit enclosure isall factory wiring, piping, controls, compressor,refrigerant charge (R22), and special features requiredprior to field start--up.

Unit Cabinet

— Unit cabinet will be constructed of galvanized,prepainted steel.

Fans

— Condenser fan will be direct--drive propeller type,discharging air upward.

— Condenser fan motors will be totally enclosed, 1--phasetype with class B insulation and permanently lubricatedbearings. Shafts will be corrosion resistant.

— Fan blades will be statically and dynamically balanced.

— Condenser fan openings will be equipped with coatedsteel wire safety guards.

Compressor

— Compressor will be hermetically sealed.

— Compressor will be mounted on rubber vibrationisolators.

Condenser Coil

— Condenser coil will be air cooled.

— Coil will be constructed of epoxy coated, enhancedaluminum fins mechanically bonded to copper tubeswhich are then cleaned, dehydrated, and sealed.

Refrigeration Components

— Refrigeration circuit components will include liquid lineshutoff valve with sweat connections, suction line shutoffvalves with sweat connections, system charge of R--22refrigerant, and compressor oil.

Operating Characteristics— The capacity of the unit will meet or exceed _____ Btuh

at a suction temperature of _____ _F (_C). The powerconsumption at full load will not exceed _____ kW.

— Combination of the unit and the evaporator or fan coilunit will have a total net cooling capacity of _____ Btuhor greater at conditions of _____ CFM entering airtemperature at the evaporator at _____ _F (_C) wet bulband _____ _F (_C) dry bulb, and air entering the unit at_____ _F (_C).

— The system will have a SEER of _____ Btuh/watt orgreater at DOE conditions.

Electrical Requirements— Nominal unit electrical characteristics will be _____ v,

single phase, 60 hz. The unit will be capable ofsatisfactory operation within voltage limits of _____ v to_____ v.

— Nominal unit electrical characteristics will be _____ v,three phase, 60 hz. The unit will be capable ofsatisfactory operation within voltage limits of _____ v to_____ v.

— Unit electrical power will be single point connection.

— Control circuit will be 24v.

Special Features— Refer to section of this literature identifying accessories

and descriptions for specific features and availableenhancements.

Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No.38CKC---C13PD

Replaces:38CKC---C12PD

Edition Date: 03/13

38CKC