Upload
rebecca-elliott
View
70
Download
4
Embed Size (px)
DESCRIPTION
nokia networks prfile parameters description
Citation preview
GSM/EDGE BSS, Rel. RG20(BSS), Operating Documentation, Issue 09
PRFILE and FIFILE Parameter List
DN9979835
Issue 13-2Approval Date 2011-08-16
Confidential
Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their compo-nents.
If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.
2 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2011. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.
The safety information is provided in the Safety Information section in the Legal, Safety and Environmental Information part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal, Safety and Environmental Information dieses Dokuments oder dieses Dokumentations-satzes.
DN9979835 3
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
Table of contentsThis document has 305 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1 Overview of PRFILE and FIFILE parameters . . . . . . . . . . . . . . . . . . . . 17
2 PRFILE and FIFILE parameter classes . . . . . . . . . . . . . . . . . . . . . . . . . 182.1 Parameter class: 000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.2 Parameter class: 001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.3 Parameter class: 002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.4 Parameter class: 003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.5 Parameter class: 004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.6 Parameter class: 005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.7 Parameter class: 006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.8 Parameter class: 007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.9 Parameter class: 008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.10 Parameter class: 009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.11 Parameter class: 010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.12 Parameter class: 011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.13 Parameter class: 012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.14 Parameter class: 013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.15 Parameter class: 014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.16 Parameter class: 015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.17 Parameter class: 016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.18 Parameter class: 017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.19 Parameter class: 018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.20 Parameter class: 019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.21 Parameter class: 020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.22 Parameter class: 021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.23 Parameter class: 022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.24 Parameter class: 023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.25 Parameter class: 024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.26 Parameter class: 025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.27 Parameter class: 026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.28 Parameter class: 027 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.29 Parameter class: 028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.30 Parameter class: 029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.31 Parameter class: 030 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.32 Parameter class: 031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.33 Parameter class: 032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.34 Parameter class: 033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.35 Parameter class: 034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.36 Parameter class: 035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.37 Parameter class: 036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.38 Parameter class: 037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.39 Parameter class: 038 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.40 Parameter class: 039 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
2.41 Parameter class: 040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.42 Parameter class: 041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.43 Parameter class: 042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.44 Parameter class: 043 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.45 Parameter class: 044 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.46 Parameter class: 045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.47 Parameter class: 046 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.48 Parameter class: 047 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.49 Parameter class: 048 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.50 Parameter class: 049 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.51 Parameter class: 050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.52 Parameter class: 051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.53 Parameter class: 052 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.54 Parameter class: 053 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.55 Parameter class: 054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.56 Parameter class: 055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.57 Parameter class: 056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.58 Parameter class: 057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.59 Parameter class: 058 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.60 Parameter class: 059 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.61 Parameter class: 060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.62 Parameter class: 061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.63 Parameter class: 062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.64 Parameter class: 063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.65 Parameter class: 064 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.66 Parameter class: 065 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.67 Parameter class: 066 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.68 Parameter class: 067 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3 PRFILE and FIFILE parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.1 Parameter class 002 SYSTEM_FUNCT_CONFIGUR . . . . . . . . . . . . . . 323.1.1 Parameter 002:0035 PRIMARY_RATE_INTERFACE . . . . . . . . . . . . . . 323.1.2 Parameter 002:0093 DOUBLE_BA_LIST . . . . . . . . . . . . . . . . . . . . . . . . 333.1.3 Parameter 002:0094 TRANSM_EQ_MML_ENABLE . . . . . . . . . . . . . . . 333.1.4 Parameter 002:0173 REMOTE_MMI . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.1.5 Parameter 002:0188 T1_ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . 343.1.6 Parameter 002:0241 Q3_DX_ALARMS_FORW_ON . . . . . . . . . . . . . . . 353.1.7 Parameter 002:0283 HR_FEATURE_IN_BSC . . . . . . . . . . . . . . . . . . . . 363.1.8 Parameter 002:0361 NORTH_AMERICAN_NUMBER. . . . . . . . . . . . . . 363.1.9 Parameter 002:0371 AEC_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.1.10 Parameter 002:0372 TFO_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.1.11 Parameter 002:0380 ALLOW_OVER_16TRX . . . . . . . . . . . . . . . . . . . . 383.1.12 Parameter 002:0399 THREE_DIGIT_MNC . . . . . . . . . . . . . . . . . . . . . . 383.1.13 Parameter 002:0417 FH_IUO_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . 393.1.14 Parameter 002:0418 SMSCB_LAST_BLOCK_INFO . . . . . . . . . . . . . . . 403.1.15 Parameter 002:0444 BTS_HW_DB_Q3_INT_IN_USE. . . . . . . . . . . . . . 403.1.16 Parameter 002:0461 BIN_HEADER_TYPE . . . . . . . . . . . . . . . . . . . . . . 413.1.17 Parameter 002:0466 FLEX_MAIO_USAGE . . . . . . . . . . . . . . . . . . . . . . 41
DN9979835 5
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.1.18 Parameter 002:0470 SMSCB_INDEPEN_MULTIPAGE . . . . . . . . . . . . 423.1.19 Parameter 002:0500 ALLOW_48_OR_64_TRX . . . . . . . . . . . . . . . . . . 433.1.20 Parameter 002:0511 ABIS_AUTOCONF_IN_USE . . . . . . . . . . . . . . . . 433.1.21 Parameter 002:0558 MS_CAP_IND_USAGE . . . . . . . . . . . . . . . . . . . . 443.1.22 Parameter 002:0602 TRE_SW_DL_MC_ADDRESS. . . . . . . . . . . . . . . 443.1.23 Parameter 002:0623 NOISE_SUPPRESSION_USAGE . . . . . . . . . . . . 453.1.24 Parameter 002:0626 DAC_USAGE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 453.1.25 Parameter 002:0628 FER_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463.1.26 Parameter 002:0643 REV_HUNT_USED . . . . . . . . . . . . . . . . . . . . . . . 473.1.27 Parameter 002:0644 DYN_ABIS_IN_USE . . . . . . . . . . . . . . . . . . . . . . 473.1.28 Parameter 002:0654 PBS_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483.1.29 Parameter 002:0664 COMMON_BCCH_EGSM900 . . . . . . . . . . . . . . . 493.1.30 Parameter 002:0665 SEGMENT_USAGE. . . . . . . . . . . . . . . . . . . . . . . 493.1.31 Parameter 002:0666 COMMON_BCCH_GSM900 . . . . . . . . . . . . . . . . 503.1.32 Parameter 002:0667 COMMON_BCCH_GSM1800 . . . . . . . . . . . . . . . 513.1.33 Parameter 002:0668 MULTI_BCF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513.1.34 Parameter 002:0693 FIRST_FREE_NUMBERED_CGR. . . . . . . . . . . . 523.1.35 Parameter 002:0701 S9_LOCATION_SYSTEM . . . . . . . . . . . . . . . . . . 533.1.36 Parameter 002:0702 TTY_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533.1.37 Parameter 002:0711 NEMU_IS_PRESENT . . . . . . . . . . . . . . . . . . . . . 543.1.38 Parameter 002:0733 COMMON_BCCH_GSM800 . . . . . . . . . . . . . . . . 543.1.39 Parameter 002:0734 COMMON_BCCH_GSM1900 . . . . . . . . . . . . . . . 553.1.40 Parameter 002:0737 GSM800_1900_USAGE . . . . . . . . . . . . . . . . . . . 563.1.41 Parameter 002:0738 GSM800_1800_USAGE . . . . . . . . . . . . . . . . . . . 563.1.42 Parameter 002:0739 ISHO_SUPPORT_IN_BSC . . . . . . . . . . . . . . . . . 573.1.43 Parameter 002:0749 LB_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583.1.44 Parameter 002:0750 LB_PLUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583.1.45 Parameter 002:0764 CITARX_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . 593.1.46 Parameter 002:0776 EMR_SUPPORT_IN_BSC. . . . . . . . . . . . . . . . . . 603.1.47 Parameter 002:0790 HW_INVENTORY_IN_USE . . . . . . . . . . . . . . . . . 603.1.48 Parameter 002:0809 ANTENNA_HOPPING_USAGE. . . . . . . . . . . . . . 613.1.49 Parameter 002:0814 Q3_IN_USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623.1.50 Parameter 002:0820 TOTAL_FEP_USAGE . . . . . . . . . . . . . . . . . . . . . 623.1.51 Parameter 002:0829 LB_STACK_IN_BCSU . . . . . . . . . . . . . . . . . . . . . 633.1.52 Parameter 002:0839 BTS_METRO_SITE_BATBU_PR . . . . . . . . . . . . 643.1.53 Parameter 002:0843 BTS_ULTRA_SITE_BATBU_PR . . . . . . . . . . . . . 643.1.54 Parameter 002:0857 CHILD_CELL_BAR . . . . . . . . . . . . . . . . . . . . . . . 653.1.55 Parameter 002:0899 EXT_UTBF_USAGE . . . . . . . . . . . . . . . . . . . . . . 663.1.56 Parameter 002:0905 UTDOA_SUPPORT . . . . . . . . . . . . . . . . . . . . . . . 663.1.57 Parameter 002:0921 HW_CHANGE_NOTIF_IN_USE . . . . . . . . . . . . . 673.1.58 Parameter 002:0947 BSR_SUPPORT_IN_BSC . . . . . . . . . . . . . . . . . . 673.1.59 Parameter 002:1006 UTDOA_COMMERCIAL . . . . . . . . . . . . . . . . . . . 683.1.60 Parameter 002:1114 EQOS_TESTING_MODE . . . . . . . . . . . . . . . . . . 693.1.61 Parameter 002:1120 LAN_ADMINISTRATION . . . . . . . . . . . . . . . . . . . 703.1.62 Parameter 002:1167 COMBI_CONF_ALLOWED . . . . . . . . . . . . . . . . . 703.1.63 Parameter 002:1264 EMR_RESTRICTED . . . . . . . . . . . . . . . . . . . . . . 713.1.64 Parameter 002:1475 RNW_OM_LOG_USAGE. . . . . . . . . . . . . . . . . . . 71
6 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.1.65 Parameter 002:1500 BSC_PCMMAP_PATH_CTRL . . . . . . . . . . . . . . . 723.1.66 Parameter 002:1521 DUPU_WITH_CDPC. . . . . . . . . . . . . . . . . . . . . . . 733.1.67 Parameter 002:1554 SEL_OCTFIL_VARIANT_TO . . . . . . . . . . . . . . . . 743.1.68 Parameter 002:1587 HW_AUTOMATIC_CMP_IN_USE . . . . . . . . . . . . 743.1.69 Parameter 002:1588 HW_MISMATCH_ALD_IN_USE . . . . . . . . . . . . . . 753.1.70 Parameter 002:1705 MAX_WAIT_TIME_BSC_RST . . . . . . . . . . . . . . . 763.1.71 Parameter 002:1829 LOW_OVERLOAD_LIMIT. . . . . . . . . . . . . . . . . . . 763.1.72 Parameter 002:1830 HIGH_OVERLOAD_LIMIT . . . . . . . . . . . . . . . . . . 773.1.73 Parameter 002:1831 CRIT_OVERLOAD_LIMIT. . . . . . . . . . . . . . . . . . . 783.1.74 Parameter 002:1832 LOAD_HYSTERESIS . . . . . . . . . . . . . . . . . . . . . . 783.1.75 Parameter 002:1833 TIME_HYSTERESIS. . . . . . . . . . . . . . . . . . . . . . . 793.1.76 Parameter 002:1870 BASE_RTP_PORT_ETPA . . . . . . . . . . . . . . . . . . 793.1.77 Parameter 002:1871 BASE_RTP_PORT_ETPC . . . . . . . . . . . . . . . . . . 803.1.78 Parameter 002:1872 PKT_DELAY_VAR . . . . . . . . . . . . . . . . . . . . . . . . 813.1.79 Parameter 002:1873 CS_CALL_LENGTH . . . . . . . . . . . . . . . . . . . . . . . 813.1.80 Parameter 002:2035 LOW_OVERLOAD_LIMIT_ETPC . . . . . . . . . . . . . 823.1.81 Parameter 002:2036 HIGH_OVRLOAD_LMT_ETPC. . . . . . . . . . . . . . . 833.1.82 Parameter 002:2037 CRIT_OVRLOAD_LMT_ETPC . . . . . . . . . . . . . . . 833.2 Parameter class 009 SYSTEM_SUPERVISION. . . . . . . . . . . . . . . . . . . 843.2.1 Parameter 009:0008 LOAD_RATE_SAMPLE_INTERV. . . . . . . . . . . . . 843.2.2 Parameter 009:0010 CRC4_TRH_FOR_DEGRAD_MIN . . . . . . . . . . . . 853.2.3 Parameter 009:0011 CRC4_TRH_FOR_ERRORE_SEC. . . . . . . . . . . . 853.2.4 Parameter 009:0028 SEC_EVENT_ALARM_LIMIT . . . . . . . . . . . . . . . . 863.2.5 Parameter 009:0029 SEC_EVENT_MON_PERIOD. . . . . . . . . . . . . . . . 863.2.6 Parameter 009:0037 BTS_SITE_BATBU_PROC. . . . . . . . . . . . . . . . . . 873.2.7 Parameter 009:0044 EXCL_EST_CAUSES_HO_REF . . . . . . . . . . . . . 873.2.8 Parameter 009:0049 BITMAP_CHECK_RECORDS . . . . . . . . . . . . . . . 883.2.9 Parameter 009:0050 BITMAP_CHECK_BYTES . . . . . . . . . . . . . . . . . . 893.2.10 Parameter 009:0051 BITMAP_SUPERV_INTERVAL . . . . . . . . . . . . . . 893.2.11 Parameter 009:0052 CHKSUM_SUPERV_INTERVAL . . . . . . . . . . . . . 903.2.12 Parameter 009:0055 TR_EQU_COLL_START_TIM . . . . . . . . . . . . . . . 903.2.13 Parameter 009:0072 CBC_INDIC_FILT_TIMER . . . . . . . . . . . . . . . . . . 913.2.14 Parameter 009:0075 NUMBER_OF_Q1_CHANNELS . . . . . . . . . . . . . . 923.2.15 Parameter 009:0079 TRE_CHKSUM_COLL_COUNT . . . . . . . . . . . . . . 923.2.16 Parameter 009:0090 BTS_Q1_RT_UPDATE_COUNT . . . . . . . . . . . . . 933.2.17 Parameter 009:0098 SDCCH_SIGN_SUP_BTS_MSC . . . . . . . . . . . . . 943.2.18 Parameter 009:0137 SEC_EVENT_LOAD_LIMIT . . . . . . . . . . . . . . . . . 943.2.19 Parameter 009:0138 SEC_EVENT_UNSUC_LIMIT. . . . . . . . . . . . . . . . 953.2.20 Parameter 009:0172 ONE_BIT_ERRORS_LIMIT . . . . . . . . . . . . . . . . . 963.3 Parameter class 010 IMPLEMENTA_OF_CALL_CTRL . . . . . . . . . . . . . 963.3.1 Parameter 010:0004 PCM_MAINT_ANNOUNCE_TL . . . . . . . . . . . . . . 963.3.2 Parameter 010:0005 DR_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 973.3.3 Parameter 010:0006 IDR_USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 973.3.4 Parameter 010:0007 TR_USAGE_IN_MTC . . . . . . . . . . . . . . . . . . . . . . 983.3.5 Parameter 010:0008 TR_USAGE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 993.3.6 Parameter 010:0011 CM_BASED_SUBS_TYPE . . . . . . . . . . . . . . . . . . 993.3.7 Parameter 010:0012 PRIOR_BASED_SERV_SEP . . . . . . . . . . . . . . . 100
DN9979835 7
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.3.8 Parameter 010:0014 C2_CELL_RESEL . . . . . . . . . . . . . . . . . . . . . . . 1003.3.9 Parameter 010:0015 FACCH_CALL_SET_UP . . . . . . . . . . . . . . . . . . 1013.3.10 Parameter 010:0016 PREEMPT_USAGE . . . . . . . . . . . . . . . . . . . . . . 1013.3.11 Parameter 010:0019 CI_BASED_HO_EVAL_P . . . . . . . . . . . . . . . . . 1023.3.12 Parameter 010:0020 EXT_CELL_USAGE_P . . . . . . . . . . . . . . . . . . . 1023.3.13 Parameter 010:0021 MS_PWR_OPT_IN_HO_P. . . . . . . . . . . . . . . . . 1033.3.14 Parameter 010:0022 SDCCH_HO_USAGE_P . . . . . . . . . . . . . . . . . . 1033.3.15 Parameter 010:0023 UNDERLAY_OVERLAY_US_P . . . . . . . . . . . . . 1043.3.16 Parameter 010:0024 CHAINED_CELL_USAGE_P. . . . . . . . . . . . . . . 1053.3.17 Parameter 010:0025 FMMS_USAGE_P . . . . . . . . . . . . . . . . . . . . . . . 1053.3.18 Parameter 010:0026 DUAL_BAND_USAGE_P. . . . . . . . . . . . . . . . . . 1063.3.19 Parameter 010:0027 RNOS_USAGE_P . . . . . . . . . . . . . . . . . . . . . . . 1063.3.20 Parameter 010:0028 RXQ_HAC_USAGE_P. . . . . . . . . . . . . . . . . . . . 1073.3.21 Parameter 010:0030 DISTANCE_VERIFYING . . . . . . . . . . . . . . . . . . 1073.3.22 Parameter 010:0031 SATELL_ABIS_IN_USE. . . . . . . . . . . . . . . . . . . 1083.3.23 Parameter 010:0032 Q3_BTS_HW_REM_INQ_USE . . . . . . . . . . . . . 1093.3.24 Parameter 010:0033 EFR_SUPPORT_IN_BSC . . . . . . . . . . . . . . . . . 1093.3.25 Parameter 010:0034 SMS_CB_DRX_USD_IN_BSC . . . . . . . . . . . . . 1103.3.26 Parameter 010:0035 HOT_SPOT_USAGE_P. . . . . . . . . . . . . . . . . . . 1113.3.27 Parameter 010:0036 CI_STATISTICS_USAGE_P . . . . . . . . . . . . . . . 1113.3.28 Parameter 010:0042 DYNAMIC_SDCCH . . . . . . . . . . . . . . . . . . . . . . 1123.3.29 Parameter 010:0044 SMS_CBC_USD_IN_BSC . . . . . . . . . . . . . . . . . 1133.3.30 Parameter 010:0045 ICE_USAGE_P . . . . . . . . . . . . . . . . . . . . . . . . . 1133.3.31 Parameter 010:0046 ERFD_USAGE_P . . . . . . . . . . . . . . . . . . . . . . . 1143.3.32 Parameter 010:0047 HSCSD_USAGE . . . . . . . . . . . . . . . . . . . . . . . . 1153.3.33 Parameter 010:0048 DATA_144_USAGE. . . . . . . . . . . . . . . . . . . . . . 1153.3.34 Parameter 010:0050 DADLB_USAGE_P . . . . . . . . . . . . . . . . . . . . . . 1163.3.35 Parameter 010:0051 DC_OBSERVATION_USAGE . . . . . . . . . . . . . . 1173.3.36 Parameter 010:0052 FCS_SET_USAGE . . . . . . . . . . . . . . . . . . . . . . 1173.3.37 Parameter 010:0053 AMH_USAGE_P . . . . . . . . . . . . . . . . . . . . . . . . 1183.3.38 Parameter 010:0065 CHAN_FIN_USAGE_P . . . . . . . . . . . . . . . . . . . 1193.3.39 Parameter 010:0068 RCS_FER_FILTER . . . . . . . . . . . . . . . . . . . . . . 1193.3.40 Parameter 010:0071 DTM_CALL_PENALTY_TIMER. . . . . . . . . . . . . 1203.4 Parameter class 012 OVERLOAD. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1213.4.1 Parameter 012:0039 NAMETBL_MAX_SERV. . . . . . . . . . . . . . . . . . . 1213.5 Parameter class 016 ALARM_SYSTEM . . . . . . . . . . . . . . . . . . . . . . . 1213.5.1 Parameter 016:0000 ALARM_PRINT_END_MARK . . . . . . . . . . . . . . 1213.5.2 Parameter 016:0001 LAMP_PANEL_POLARITY . . . . . . . . . . . . . . . . 1223.5.3 Parameter 016:0002 ALARM_DRIVEN_OUTPUTS . . . . . . . . . . . . . . 1233.5.4 Parameter 016:0003 LAMP_PANEL_BUZZER . . . . . . . . . . . . . . . . . . 1233.5.5 Parameter 016:0007 BTS_ALARM_FILTERING_USE . . . . . . . . . . . . 1243.6 Parameter class 037 RADIO_NW_CTRL_REL . . . . . . . . . . . . . . . . . . 1253.6.1 Parameter 037:0000 ATTN_FOR_2_GEN_BTS . . . . . . . . . . . . . . . . . 1253.6.2 Parameter 037:0001 ATTN_FOR_3_GEN_BTS . . . . . . . . . . . . . . . . . 1263.6.3 Parameter 037:0002 ATTN_FOR_4_GEN_BTS . . . . . . . . . . . . . . . . . 1263.6.4 Parameter 037:0003 ATTENUATED_CH_NBR_1 . . . . . . . . . . . . . . . 1273.6.5 Parameter 037:0004 ATTENUATED_CH_NBR_2 . . . . . . . . . . . . . . . 127
8 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.6.6 Parameter 037:0005 ATTENUATED_CH_NBR_3 . . . . . . . . . . . . . . . . 1283.6.7 Parameter 037:0006 ATTENUATED_CH_NBR_4 . . . . . . . . . . . . . . . . 1283.6.8 Parameter 037:0007 ATTENUATED_CH_NBR_5 . . . . . . . . . . . . . . . . 1293.6.9 Parameter 037:0008 ATTENUATED_CH_NBR_6 . . . . . . . . . . . . . . . . 1303.6.10 Parameter 037:0009 ATTENUATED_CH_NBR_7 . . . . . . . . . . . . . . . . 1303.6.11 Parameter 037:0010 ATTENUATED_CH_NBR_8 . . . . . . . . . . . . . . . . 1313.6.12 Parameter 037:0011 ATTENUATED_CH_NBR_9 . . . . . . . . . . . . . . . . 1313.6.13 Parameter 037:0012 ATTENUATED_CH_NBR_10 . . . . . . . . . . . . . . . 1323.6.14 Parameter 037:0013 ATTENUATED_CH_NBR_11 . . . . . . . . . . . . . . . 1323.6.15 Parameter 037:0014 ATTENUATED_CH_NBR_12 . . . . . . . . . . . . . . . 1333.6.16 Parameter 037:0015 ATTENUATED_CH_NBR_13 . . . . . . . . . . . . . . . 1333.6.17 Parameter 037:0016 ATTENUATED_CH_NBR_14 . . . . . . . . . . . . . . . 1343.6.18 Parameter 037:0017 ATTENUATED_CH_NBR_15 . . . . . . . . . . . . . . . 1343.6.19 Parameter 037:0018 ATTENUATED_CH_NBR_16 . . . . . . . . . . . . . . . 1353.6.20 Parameter 037:0019 ATTENUATED_CH_NBR_17 . . . . . . . . . . . . . . . 1353.6.21 Parameter 037:0022 ATTN_FOR_METROSITE_BTS . . . . . . . . . . . . . 1363.6.22 Parameter 037:0024 ATTN_FOR_ULTRASITE_BTS . . . . . . . . . . . . . 1373.6.23 Parameter 037:0025 ATTN_FOR_INSITE_BTS. . . . . . . . . . . . . . . . . . 1373.6.24 Parameter 037:0026 ATT_850_CH_NBR_1. . . . . . . . . . . . . . . . . . . . . 1383.6.25 Parameter 037:0027 ATT_850_CH_NBR_2. . . . . . . . . . . . . . . . . . . . . 1383.6.26 Parameter 037:0028 ATT_850_CH_NBR_3. . . . . . . . . . . . . . . . . . . . . 1393.6.27 Parameter 037:0029 ATT_850_CH_NBR_4. . . . . . . . . . . . . . . . . . . . . 1393.6.28 Parameter 037:0030 ATT_850_CH_NBR_5. . . . . . . . . . . . . . . . . . . . . 1403.6.29 Parameter 037:0031 ATT_850_CH_NBR_6. . . . . . . . . . . . . . . . . . . . . 1403.6.30 Parameter 037:0032 ATT_850_CH_NBR_7. . . . . . . . . . . . . . . . . . . . . 1413.6.31 Parameter 037:0033 ATT_850_CH_NBR_8. . . . . . . . . . . . . . . . . . . . . 1413.6.32 Parameter 037:0034 ATT_850_CH_NBR_9. . . . . . . . . . . . . . . . . . . . . 1423.6.33 Parameter 037:0035 ATT_850_CH_NBR_10. . . . . . . . . . . . . . . . . . . . 1423.6.34 Parameter 037:0036 INC_SIGNAL_WAITING_TIME. . . . . . . . . . . . . . 1433.6.35 Parameter 037:0037 ATTN_FOR_800_CH_6_ULTRA . . . . . . . . . . . . 1443.6.36 Parameter 037:0038 ATTN_FOR_800_CH_7_ULTRA . . . . . . . . . . . . 1443.6.37 Parameter 037:0039 IUO_RECOVERY_NOT_DONE . . . . . . . . . . . . . 1453.6.38 Parameter 037:0040 MAX_BSC_TRE_SW_DL_COUNT. . . . . . . . . . . 1453.6.39 Parameter 037:0041 MAX_BTS_TRE_SW_DL_COUNT . . . . . . . . . . . 1463.6.40 Parameter 037:0042 SYNC_RECOV_ENABLED. . . . . . . . . . . . . . . . . 1463.6.41 Parameter 037:0043 LMUSYN_LOSS_ALARM_LIMIT . . . . . . . . . . . . 1473.6.42 Parameter 037:0044 LMUSYN_LOSS_RESET_LIMIT . . . . . . . . . . . . 1483.6.43 Parameter 037:0046 LMUSYN_LOSS_C_RESET_LIM . . . . . . . . . . . . 1483.7 Parameter class 038 MML_COMMAND_LOG . . . . . . . . . . . . . . . . . . . 1493.7.1 Parameter 038:0000 WRITE_CACHE_TIMEOUT . . . . . . . . . . . . . . . . 1493.7.2 Parameter 038:0001 STORAGE_LENGTH . . . . . . . . . . . . . . . . . . . . . 1503.7.3 Parameter 038:0002 MAX_FILE_COUNT . . . . . . . . . . . . . . . . . . . . . . 1503.7.4 Parameter 038:0003 ADMINISTRATION_HOUR. . . . . . . . . . . . . . . . . 1513.7.5 Parameter 038:0004 ADMINISTRATION_MINUTES . . . . . . . . . . . . . . 1523.8 Parameter class 044 MML_SESSION . . . . . . . . . . . . . . . . . . . . . . . . . 1523.8.1 Parameter 044:0000 PW_CHAR_TO_PRINT . . . . . . . . . . . . . . . . . . . 1523.8.2 Parameter 044:0001 FIRST_MMI_LOGIN_DELAY . . . . . . . . . . . . . . . 153
DN9979835 9
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.8.3 Parameter 044:0002 MAX_MMI_LOGIN_DELAY . . . . . . . . . . . . . . . . 1533.8.4 Parameter 044:0003 OVERFLOW_LOGIN_DELAY . . . . . . . . . . . . . . 1543.8.5 Parameter 044:0005 DISCLAIMER_TEXT . . . . . . . . . . . . . . . . . . . . . 1553.8.6 Parameter 044:0006 DEF_MAIN_HEADING_TEXT . . . . . . . . . . . . . . 1553.9 Parameter class 046 PCU_TELECOM_PARAMETERS . . . . . . . . . . . 1563.9.1 Parameter 046:0046 MEMORY_OUT_FLAG_SUM . . . . . . . . . . . . . . 1563.9.2 Parameter 046:0047 EGPRS_UPLINK_PENALTY . . . . . . . . . . . . . . . 1573.9.3 Parameter 046:0048 EGPRS_UPLINK_THRESHOLD . . . . . . . . . . . . 1583.9.4 Parameter 046:0049 EGPRS_DOWNLINK_PENALTY. . . . . . . . . . . . 1583.9.5 Parameter 046:0050 EGPRS_DWNLINK_THRESHOLD . . . . . . . . . . 1593.9.6 Parameter 046:0051 GPRS_UPLINK_PENALTY . . . . . . . . . . . . . . . . 1603.9.7 Parameter 046:0052 GPRS_UPLINK_THRESHOLD . . . . . . . . . . . . . 1603.9.8 Parameter 046:0053 GPRS_DOWNLINK_PENALTY . . . . . . . . . . . . . 1613.9.9 Parameter 046:0054 GPRS_DOWNLINK_THRESHOLD . . . . . . . . . . 1623.9.10 Parameter 046:0055 UPLNK_RX_LEV_FRG_FACTOR. . . . . . . . . . . 1623.9.11 Parameter 046:0059 TERRIT_BALANCE_THRSHLD . . . . . . . . . . . . 1633.9.12 Parameter 046:0060 TERRIT_UPD_GTIME_GPRS. . . . . . . . . . . . . . 1643.9.13 Parameter 046:0061 TBF_LOAD_GUARD_THRSHLD. . . . . . . . . . . . 1653.9.14 Parameter 046:0062 TBF_SIGNAL_GRD_THRSHLD . . . . . . . . . . . . 1653.9.15 Parameter 046:0064 PRE_EMPTIVE_TRANSMISSIO . . . . . . . . . . . . 1663.9.16 Parameter 046:0066 BCCH_BAND_TBF_THRSHLD . . . . . . . . . . . . . 1663.9.17 Parameter 046:0067 DL_TBF_RELEASE_DELAY . . . . . . . . . . . . . . . 1673.9.18 Parameter 046:0068 UL_TBF_RELEASE_DELAY . . . . . . . . . . . . . . . 1683.9.19 Parameter 046:0071 UL_TBF_REL_DELAY_EXT . . . . . . . . . . . . . . . 1683.9.20 Parameter 046:0072 UL_TBF_SCHED_RATE_EXT. . . . . . . . . . . . . . 1693.9.21 Parameter 046:0085 POLLING_INTERVAL_STRM . . . . . . . . . . . . . . 1693.9.22 Parameter 046:0086 POLLING_INTERVAL_IA. . . . . . . . . . . . . . . . . . 1703.9.23 Parameter 046:0087 POLLING_INTERVAL_BG. . . . . . . . . . . . . . . . . 1713.9.24 Parameter 046:0090 PFC_PFT_LEGACY_STRM . . . . . . . . . . . . . . . 1713.9.25 Parameter 046:0091 EGPRS_GPRS_MUX_PENALTY . . . . . . . . . . . 1723.9.26 Parameter 046:0092 GPRS_UL_MUX_DEC_FACTOR . . . . . . . . . . . 1723.9.27 Parameter 046:0093 EGPRS_DL_MUX_DEC_FACTOR . . . . . . . . . . 1733.9.28 Parameter 046:0096 NCCR_NON_DRX_PERIOD . . . . . . . . . . . . . . . 1743.9.29 Parameter 046:0097 NCCR_MEAS_REPORT_TYPE . . . . . . . . . . . . 1743.9.30 Parameter 046:0099 SUSPEND_PCU_LOAD_NOTIF . . . . . . . . . . . . 1753.9.31 Parameter 046:0100 CHA_CONC_UL_TBF_FAV_DIR . . . . . . . . . . . 1763.9.32 Parameter 046:0101 CHA_CONC_DL_TBF_FAV_DIR . . . . . . . . . . . 1773.9.33 Parameter 046:0102 PFC_PFT_MAX_NRT . . . . . . . . . . . . . . . . . . . . 1773.9.34 Parameter 046:0103 PFC_PFT_MAX_RT. . . . . . . . . . . . . . . . . . . . . . 1783.9.35 Parameter 046:0105 DTM_CALL_ASSIGN_TIMER . . . . . . . . . . . . . . 1793.9.36 Parameter 046:0106 MAX_LAPD_LENGHT . . . . . . . . . . . . . . . . . . . . 1793.9.37 Parameter 046:0107 DTM_MS_CL_11_SUPP_EDA . . . . . . . . . . . . . 1803.9.38 Parameter 046:0109 IBNACC_POLLING_TIME . . . . . . . . . . . . . . . . . 1813.9.39 Parameter 046:0110 LBNCCR_MIN_INTERVAL_PLR . . . . . . . . . . . . 1813.9.40 Parameter 046:0111 QOS_UPGRADE_TIME. . . . . . . . . . . . . . . . . . . 1823.9.41 Parameter 046:0113 POLLING_INTERVAL_BG_LOW. . . . . . . . . . . . 1823.9.42 Parameter 046:0114 POLLING_INTERVAL_IA_LOW . . . . . . . . . . . . 183
10 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.9.43 Parameter 046:0115 POLLING_INTERVAL_ST_LOW . . . . . . . . . . . . 1843.9.44 Parameter 046:0116 DL_DTM_TBF_REL_DELAY . . . . . . . . . . . . . . . 1843.9.45 Parameter 046:0117 UL_DTM_TBF_RELDELAY_EXT . . . . . . . . . . . . 1853.9.46 Parameter 046:0118 UL_DTM_TBF_REL_DELAY . . . . . . . . . . . . . . . 1863.9.47 Parameter 046:0119 RESEGMENT_MODE. . . . . . . . . . . . . . . . . . . . . 1863.9.48 Parameter 046:0123 PCU_COLD_RST_ALLOWED . . . . . . . . . . . . . . 1873.9.49 Parameter 046:0126 BTS_DLDC_TSL_BALANC_THR . . . . . . . . . . . . 1883.10 Parameter class 049 GB_INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . 1883.10.1 Parameter 049:0000 TNS_BLOCK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1883.10.2 Parameter 049:0001 TNS_RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1893.10.3 Parameter 049:0002 TNS_TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1893.10.4 Parameter 049:0003 TNS_ALIVE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1903.10.5 Parameter 049:0005 NS_BLOCK_RETRIES . . . . . . . . . . . . . . . . . . . . 1903.10.6 Parameter 049:0006 NS_UNBLOCK_RETRIES . . . . . . . . . . . . . . . . . 1913.10.7 Parameter 049:0007 NS_ALIVE_RETRIES . . . . . . . . . . . . . . . . . . . . . 1913.10.8 Parameter 049:0008 NS_RESET_RETRIES . . . . . . . . . . . . . . . . . . . . 1923.10.9 Parameter 049:0009 TGB_BLOCK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1933.10.10 Parameter 049:0010 TGB_RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1933.10.11 Parameter 049:0011 TGB_SUSPEND . . . . . . . . . . . . . . . . . . . . . . . . . 1943.10.12 Parameter 049:0013 BVC_BLOCK_RETRIES . . . . . . . . . . . . . . . . . . . 1943.10.13 Parameter 049:0014 BVC_UNBLOCK_RETRIES . . . . . . . . . . . . . . . . 1953.10.14 Parameter 049:0015 BVC_RESET_RETRIES . . . . . . . . . . . . . . . . . . . 1953.10.15 Parameter 049:0016 SUSPEND_RETRIES . . . . . . . . . . . . . . . . . . . . . 1963.10.16 Parameter 049:0020 FC_R_DIF_TRG_LIMIT . . . . . . . . . . . . . . . . . . . 1963.10.17 Parameter 049:0021 FC_MS_R_DEF . . . . . . . . . . . . . . . . . . . . . . . . . 1973.10.18 Parameter 049:0022 FC_MS_R_DEF_EGPRS . . . . . . . . . . . . . . . . . . 1973.10.19 Parameter 049:0023 FC_MS_R_MIN. . . . . . . . . . . . . . . . . . . . . . . . . . 1983.10.20 Parameter 049:0024 FC_MS_B_MAX_DEF. . . . . . . . . . . . . . . . . . . . . 1983.10.21 Parameter 049:0025 FC_MS_B_MAX_DEF_EGPRS . . . . . . . . . . . . . 1993.10.22 Parameter 049:0026 FC_R_TSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1993.10.23 Parameter 049:0027 FC_R_TSL_EGPRS . . . . . . . . . . . . . . . . . . . . . . 2003.10.24 Parameter 049:0028 FC_B_MAX_TSL. . . . . . . . . . . . . . . . . . . . . . . . . 2003.10.25 Parameter 049:0029 FC_B_MAX_TSL_EGPRS . . . . . . . . . . . . . . . . . 2013.10.26 Parameter 049:0031 TSNS_PROV . . . . . . . . . . . . . . . . . . . . . . . . . . . 2023.10.27 Parameter 049:0032 SNS_ADD_RETRIES . . . . . . . . . . . . . . . . . . . . . 2023.10.28 Parameter 049:0033 SNS_CONFIG_RETRIES . . . . . . . . . . . . . . . . . . 2033.10.29 Parameter 049:0034 SNS_CHANGEWEIGHTS_RETRI . . . . . . . . . . . 2033.10.30 Parameter 049:0035 SNS_DELETE_RETRIES . . . . . . . . . . . . . . . . . . 2043.10.31 Parameter 049:0036 SNS_SIZE_RETRIES . . . . . . . . . . . . . . . . . . . . . 2043.10.32 Parameter 049:0037 TGB_RAC_UPDATE. . . . . . . . . . . . . . . . . . . . . . 2053.10.33 Parameter 049:0038 RAC_UPDATE_RETRIES . . . . . . . . . . . . . . . . . 2053.10.34 Parameter 049:0052 CONVERSATIONAL_ARP1 . . . . . . . . . . . . . . . . 2063.10.35 Parameter 049:0053 CONVERSATIONAL_ARP2 . . . . . . . . . . . . . . . . 2063.10.36 Parameter 049:0054 CONVERSATIONAL_ARP3 . . . . . . . . . . . . . . . . 2073.10.37 Parameter 049:0055 STREAMING_ARP1 . . . . . . . . . . . . . . . . . . . . . . 2083.10.38 Parameter 049:0056 STREAMING_ARP2 . . . . . . . . . . . . . . . . . . . . . . 2083.10.39 Parameter 049:0057 STREAMING_ARP3 . . . . . . . . . . . . . . . . . . . . . . 209
DN9979835 11
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
3.10.40 Parameter 049:0058 INTERACT_PRIOR_1_ARP1 . . . . . . . . . . . . . . 2093.10.41 Parameter 049:0059 INTERACT_PRIOR_1_ARP2 . . . . . . . . . . . . . . 2103.10.42 Parameter 049:0060 INTERACT_PRIOR_1_ARP3 . . . . . . . . . . . . . . 2113.10.43 Parameter 049:0061 INTERACT_PRIOR_2_ARP1 . . . . . . . . . . . . . . 2113.10.44 Parameter 049:0062 INTERACT_PRIOR_2_ARP2 . . . . . . . . . . . . . . 2123.10.45 Parameter 049:0063 INTERACT_PRIOR_2_ARP3 . . . . . . . . . . . . . . 2123.10.46 Parameter 049:0064 INTERACT_PRIOR_3_ARP1 . . . . . . . . . . . . . . 2133.10.47 Parameter 049:0065 INTERACT_PRIOR_3_ARP2 . . . . . . . . . . . . . . 2143.10.48 Parameter 049:0066 INTERACT_PRIOR_3_ARP3 . . . . . . . . . . . . . . 2143.10.49 Parameter 049:0067 BACKGROUND_ARP1 . . . . . . . . . . . . . . . . . . . 2153.10.50 Parameter 049:0068 BACKGROUND_ARP2 . . . . . . . . . . . . . . . . . . . 2153.10.51 Parameter 049:0069 BACKGROUND_ARP3 . . . . . . . . . . . . . . . . . . . 2163.10.52 Parameter 049:0072 RESUME_RETRIES . . . . . . . . . . . . . . . . . . . . . 2173.10.53 Parameter 049:0073 TGB_RESUME . . . . . . . . . . . . . . . . . . . . . . . . . 2173.10.54 Parameter 049:0082 PS_NULL_NRI_SUPPORT . . . . . . . . . . . . . . . . 2183.11 Parameter class 050 REPORT_FORMING. . . . . . . . . . . . . . . . . . . . . 2183.11.1 Parameter 050:0001 MEA_REPORT_FORMATS. . . . . . . . . . . . . . . . 2183.12 Parameter class 053 MSC_SERVER_PARAMETERS . . . . . . . . . . . . 2193.12.1 Parameter 053:0000 MSC_SERVER_SUPPORTED . . . . . . . . . . . . . 2193.12.2 Parameter 053:0009 DSCP_FOR_SIGNALLING . . . . . . . . . . . . . . . . 2203.13 Parameter class 056 STLOG_FACILITIES . . . . . . . . . . . . . . . . . . . . . 2213.13.1 Parameter 056:0000 LOG_ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2213.14 Parameter class 058 OAM_SECURITY. . . . . . . . . . . . . . . . . . . . . . . . 2223.14.1 Parameter 058:0000 PW_POLICY_FEATURE . . . . . . . . . . . . . . . . . . 2223.14.2 Parameter 058:0001 UA_POLICY_FEATURE . . . . . . . . . . . . . . . . . . 2233.14.3 Parameter 058:0002 SSH_SERVER_FEATURE . . . . . . . . . . . . . . . . 2243.14.4 Parameter 058:0003 SFTP_SERVER_FEATURE . . . . . . . . . . . . . . . 2243.14.5 Parameter 058:0004 USER_ACCOUNT_LOCK_LIMIT . . . . . . . . . . . 2253.14.6 Parameter 058:0005 CONF_INTERFACES_FEATURE . . . . . . . . . . . 2263.15 Parameter class 060 MANAGEMENT_PROTOCOLS. . . . . . . . . . . . . 2273.15.1 Parameter 060:0000 Q3_FM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2273.15.2 Parameter 060:0001 Q3_PM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2273.15.3 Parameter 060:0002 Q3_CM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2283.15.4 Parameter 060:0003 Q3_SW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2293.15.5 Parameter 060:0004 Q3_HW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2293.15.6 Parameter 060:0005 Q3_TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2303.15.7 Parameter 060:0006 Q3_UM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2303.15.8 Parameter 060:0007 NE3S_FM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2313.15.9 Parameter 060:0008 NE3S_PM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2323.15.10 Parameter 060:0009 NE3S_CM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2323.15.11 Parameter 060:0010 NE3S_SW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2333.15.12 Parameter 060:0011 NE3S_LM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2333.15.13 Parameter 060:0012 NE3S_HW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2343.15.14 Parameter 060:0013 NE3S_UM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2353.15.15 Parameter 060:0014 NE3S_TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . 2353.15.16 Parameter 060:0015 NE3S_ATL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2363.15.17 Parameter 060:0016 NE3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
12 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
4 PRFILE and FIFILE parameter index by parameter class . . . . . . . . . . 238
5 PRFILE and FIFILE parameter index by parameter name . . . . . . . . . . 256
6 PRFILE and FIFILE parameter index by parameter function . . . . . . . . 272
7 PRFILE and FIFILE parameter index by parameter number . . . . . . . . 289
DN9979835 13
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
List of tablesTable 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Table 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Table 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Table 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187Table 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237Table 6 Index by parameter class. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238Table 7 Index by parameter name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256Table 8 Index by parameter function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272Table 9 Index by parameter number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
14 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d80580895687Confidential
DN9979835 15
PRFILE and FIFILE Parameter List Summary of changes
Id:0900d805808a9397Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Changes made between issues 13-2 and 13-1The following parameters are new:
002:2035 LOW_OVERLOAD_LIMIT_ETPC 002:2036 HIGH_OVRLOAD_LMT_ETPC 002:2037 CRIT_OVRLOAD_LMT_ETPCChanges made between issues 13-1 and 13-0The following parameters are new:
009:0172 ONE_BIT_ERRORS_LIMITChanges made between issues 13-0 and 12-0Added new parameter class 66 and 67.
Added new parameter index by parameter class NE3S.
The following parameters are new:
002:1521 DUPU_WITH_CDPC 002:1587 HW_AUTOMATIC_CMP_IN_USE 002:1588 HW_MISMATCH_ALD_IN_USE 002:1705 MAX_WAIT_TIME_BSC_RST 002:1829 LOW_OVERLOAD_LIMIT 002:1830 HIGH_OVERLOAD_LIMIT 002:1831 CRIT_OVERLOAD_LIMIT 002:1832 LOAD_HYSTERESIS 002:1833 TIME_HYSTERESIS 002:1870 BASE_RTP_PORT_ETPA 002:1871 BASE_RTP_PORT_ETPC 002:1872 PKT_DELAY_VAR 002:1873 CS_CALL_LENGTH 046:0123 PCU_COLD_RST_ALLOWED 060:0016 NE3SThe following parameters have been modified:
002:0188 T1_ENVIRONMENT 002:0664 COMMON_BCCH_EGSM900 002:0666 COMMON_BCCH_GSM900 050:0001 MEA_REPORT_FORMATSChanges made between issues 12-0 and 11-2Added new parameter class 59.
The following parameters are new:
002:1475 RNW_OM_LOG_USAGE 002:1500 BSC_PCMMAP_PATH_CTRL 002:1554 SEL_OCTFIL_VARIANT_TO
16 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9397Confidential
Summary of changes
046:0119 RESEGMENT_MODE 046:0126 BTS_DLDC_TSL_BALANC_THR 056:0000 LOG_ON 058:0004 USER_ACCOUNT_LOCK_LIMIT 058:0005 CONF_INTERFACES_FEATUREChanges made between issues 11-2 and 11-1Parameter 002:0858 ADJC_INDEX_USAGE_IN_Q3 has been removed.
Changes made between issues 11-1 and 11-0Parameter 046:0112 NEW_DL_TBF_RET_DELAY has been removed.
The maximum value of parameter 049:0008 NS_RESET_RETRIES has been changed.
DN9979835 17
PRFILE and FIFILE Parameter List Overview of PRFILE and FIFILE parameters
Id:0900d8058075d096Confidential
1 Overview of PRFILE and FIFILE parametersParameters are handled in the BSC with the aid of three parameter files: PRFILE (General Parameter File), FIFILE (Feature Information Control File) and PAFILE (BSC Control Parameter File). All the information about controlling the basic software and application software of the BSC is stored in the PRFILE and FIFILE. The files are admin-istered (modification, output) with the Parameter Handling MML (WO command group). PAFILE is used for storing modified values of GSM/BSC parameters.
PRFILE and FIFILEThe BSC has a set of application software solutions which are not included in the basic software but the customer can choose them to be included (optional). There is also a set of application software solutions which are typical in all BSCs but the extent of their use depends on the delivery (standard).
All the information about controlling the above software is assembled in the BSC in the PRFILE (General Parameter File) and the FIFILE (Feature Information Control File). The FIFILE file has been created for optionality parameters from the PRFILE. The FIFILE file is located in all computer units into which it is loaded from OMU disk. The FIFILE contains parameters which control the new application software and the activa-tion status of the new optionality parameters. Both the FIFILE and the PRFILE are generic files. The same FIFILE(GX) is used for every network element. You can modify and interrogate the contents of the files with the Parameter Handling MML WO command group commands.
For more detailed instructions on the commands and their parameters, see WO - Parameter Handling under Reference/Commands/MML Commands.
Interrogating and modifying standard, S9 and previous releases' optional param-etersTo interrogate the value of a standard delivery parameter, use the command WOI.To modify the value of a standard delivery parameter, or S9 and previous releases' optional delivery parameter, use the command WOC.Interrogating and modifying S10 and later optional parametersTo list and output BSC S10 or later application software, use the command WOS.To activate or deactivate a BSC S10 or later application software, use the command WOA.
18 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
2 PRFILE and FIFILE parameter classes
2.1 Parameter class: 000ANNOUNCEMENT_DEVICE
Descriptive NameTechnical parameters of announcement device
DescriptionThis class includes technical parameters of the announcement device that are related to time supervision and release sequences.
2.2 Parameter class: 001CHARGING
Descriptive NameCharging
DescriptionThis class includes charging parameters.
2.3 Parameter class: 002SYSTEM_FUNCT_CONFIGUR
Descriptive NameSystem functions configuration
DescriptionParameters in this class specify the functional configuration of each delivery, i.e. the functions that are included or excluded.
2.4 Parameter class: 003SUBSCRIBER_FACILITIES
Descriptive NameParameters of subscriber facilities
DescriptionThe parameter class includes information on the use of subscriber facilities in the delivery configuration.
2.5 Parameter class: 004THREE_PARTY_FACILITIES
DN9979835 19
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
Descriptive NameThree party facilities
DescriptionThis parameter class includes information on the delivery configuration of three party facilities.
2.6 Parameter class: 005OPERATOR_CALL
Descriptive NameOperator call parameters
DescriptionThe class includes technical parameters of operator calls. These parameters are related to time limits, audible tones and queuing parameters of calls.
2.7 Parameter class: 006CALL_TECHNIC_TIM_LIMI
Descriptive NameTime limits
DescriptionThis class includes definitions for call time limits.
2.8 Parameter class: 007CALL_CONTROL
Descriptive NameCall control
DescriptionThis class includes call control definitions.
2.9 Parameter class: 008ACCESS_SERVER
Descriptive NameAccess Server parameters
DescriptionThe parameter class contains parameters related to IP Access Server.
2.10 Parameter class: 009SYSTEM_SUPERVISION
20 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
Descriptive NameSystem supervision limit values
DescriptionThis class includes limit values related to the monitoring of system functions.
2.11 Parameter class: 010IMPLEMENTA_OF_CALL_CTRL
Descriptive NameImplementation of call control
DescriptionThis class includes implementation values of call control.
2.12 Parameter class: 011SYSTEM_DIMENSIONING
Descriptive NameSystem dimensioning
DescriptionParameters in this class are used to set exchange dimensions that can vary from one delivery to another.
2.13 Parameter class: 012OVERLOAD
Descriptive NameOverload handling
DescriptionThe class includes parameters needed in overload handling.
2.14 Parameter class: 013PRIORITY_CALLS
Descriptive NameParameters of the Priority facility
DescriptionThe class includes the parameters needed in implementing the Priority subscriber facil-ity.
2.15 Parameter class: 014INCOM_CALL_BARRING
DN9979835 21
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
Descriptive NameIncoming Call Barring facility definitions
DescriptionThe parameters of this class define how an incoming call barring category is handled. At least 32 bits are needed for each barring category (3 words because the field value cannot be 0FFFFH). Each bit corresponds to a subscriber class. If the value of the bit corresponding to the A-subscriber class is 0, the call cannot be established. There are three barring categories.
2.16 Parameter class: 015SUBSC_NBR_ANALYSIS
Descriptive NameSubscriber number analysis
DescriptionThis class includes parameters related to the subscriber number analysis.
2.17 Parameter class: 016ALARM_SYSTEM
Descriptive NameAlarm system
DescriptionThis class includes parameters of the alarm system.
2.18 Parameter class: 017CALL_FORWARDING
Descriptive NameCall forwarding
DescriptionThis class includes parameters of call forwarding.
2.19 Parameter class: 018DX_SCP
Descriptive NameParameters for DX-based IN-services
DescriptionAmongst IN-services that are implemented as DX-processes some details are made user-adaptable. These details contain e.g. method codes and number of retrials, which by parameterization can be set delivery specific.
22 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
2.20 Parameter class: 019WAKE_UP_FACILITY
Descriptive NameWake-up facility
DescriptionThis class includes definitions for the attributes used by the wake-up facility.
2.21 Parameter class: 020CARRIER_ACCESS_CODES
Descriptive NameCarrier access codes
DescriptionThe class includes the carrier access codes identified by the exchange.
2.22 Parameter class: 021COMPLETION_OF_CALL
Descriptive NameCall completion
DescriptionThis class includes parameters for completion of calls.
2.23 Parameter class: 022DX_RF_CODES
Descriptive NameDX RF codes
DescriptionThe class includes parameters for facilities that are implemented using the IN technique.
2.24 Parameter class: 023DN_SIGNAL
Descriptive NameSignalling of DAXnode
DescriptionThis class includes the signalling parameters of the DAXnode.
DN9979835 23
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
2.25 Parameter class: 024V5_INTERFACE
Descriptive NameV5 interface
DescriptionThe class includes parameters of the V5 interface.
2.26 Parameter class: 025DIGITAL_CROSS_CONNECT
Descriptive NameParameters for digital cross-connection
DescriptionThe class includes general parameters for the DX 200 DCS digital cross-connection system.
2.27 Parameter class: 026OWN_ADDR
Descriptive NameOwn address of the exchange
DescriptionThe class includes the parameters that are used to address to the own exchange.
2.28 Parameter class: 027EOS_ATTRIBUTES
Descriptive NameEOS attribute parameters
DescriptionAll EOS attribute parameters are described in this parameter class (FN597).
2.29 Parameter class: 028ROUTING_ATTRIBUTES
Descriptive NameRouting attributes
DescriptionAll attribute parameters of routing are described in this parameter class (FN597).
24 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
2.30 Parameter class: 029AIF_ATTRIBUTES
Descriptive NameAttributes of A-interface
DescriptionAll attribute parameters of the A-interface are described in this class (FN597).
2.31 Parameter class: 030CHARGING_ATTRIBUTES
Descriptive NameCharging attributes
DescriptionAll attribute parameters for charging are described in this parameter class (FN597).
2.32 Parameter class: 031SHORT_MESSAGE_SERVICE
Descriptive NameShort message service parameters
DescriptionThe short message service parameter class includes special parameters for controlling CP-DATA message resending and short message queueing.
2.33 Parameter class: 032CM_ATTRIBUTE_CONTROL
Descriptive NameControl parameters for central memory attributes
DescriptionThe class includes general control parameters of attribute-directed routing. These parameters are used for adjusting the functionality of attribute-directed routing features.
2.34 Parameter class: 033CM_ATTRIBUTES
Descriptive NameCentral memory attribute types
DN9979835 25
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
DescriptionThe class includes parameters for controlling the visibility of attribute types existing in the exchange. These parameters are used to define the nature of the attribute set used by the customer. All parameters of this class are secret to the customer.
2.35 Parameter class: 034NTN_COMM_OPTIONS
Descriptive NameNTNSYS commercial options
DescriptionThis parameter class includes commercial options of the Nokia Siemens Networks Tetra Network system.
2.36 Parameter class: 035CALL_PARK
Descriptive NameCall park
DescriptionThe class includes parameters of the Centrex feature Call Park.
2.37 Parameter class: 036SUBSC_IDENTIFICATION
Descriptive NameSubscriber identification
DescriptionThe class includes parameters of the features CLIP/CLIR and COLP/COLR.
2.38 Parameter class: 037RADIO_NW_CTRL_REL
Descriptive NameRadio network controlling
DescriptionThe parameter class contains parameters that are used in controlling the functioning of the radio network in BSC, i.e. the minimum attenuation of TX-power in certain frequen-cies.
2.39 Parameter class: 038MML_COMMAND_LOG
26 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
Descriptive NameMML Command Log parameters
DescriptionThe parameter class includes parameters to define timeout values and disk usage restrictions of the MML Command Log.
2.40 Parameter class: 039CHA_MODIFICATION
Descriptive NameCharging modification parameters
DescriptionParameter class for charging modification attributes (30138).
2.41 Parameter class: 040ECT_PARAMETERS
Descriptive NameExplict Call Transfer parameters
DescriptionThis class contains parameters of the Explicit Call Transfer feature.
2.42 Parameter class: 041CAMEL_PARAMETERS
Descriptive NameCAMEL parameters
DescriptionThis parameter class contains parameters related with CAMEL.
2.43 Parameter class: 042QSIG_PARAMETERS
Descriptive NameQSIG parameters
DescriptionThis parameter class contains parameters related with QSIG.
2.44 Parameter class: 043IWF_CTRL_PARAMETER
DN9979835 27
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
Descriptive NameControl parameters of interworking functions configuration
DescriptionThis parameter class defines the control parameters of the features or functions used by the IWF.
2.45 Parameter class: 044MML_SESSION
Descriptive NameMML Session parameters
DescriptionThis parameter class includes parameters concerning MML session.
2.46 Parameter class: 045NTN_FEATURE_AND_ATTRI
Descriptive NameNTNSYS features and attributes
DescriptionThis parameter class includes some features and attributes of the Nokia Tetra System, e.g. the default routing DXT for the own exchange.
2.47 Parameter class: 046PCU_TELECOM_PARAMETERS
Descriptive NamePCU Telecom Parameters
DescriptionThe parameter class contains parameters related to PCU Telecom.
2.48 Parameter class: 047V5_PSTN_MAPPING_PARAM
Descriptive NameV5 PSTN mapping parameters
DescriptionThe class includes the parameters which determine the operation of the V5 PSTN mapping (PSTN = Public Switched Telephone Network).
28 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
2.49 Parameter class: 048V5_PSTN_MAPPING_PARAM_2
Descriptive NameAlternative V5 PSTN mapping 2 parameters
DescriptionThe class includes the alternative parameters which determine the operation of the V5 PSTN mapping 2 (PSTN = Public Switched Telephone Network).
2.50 Parameter class: 049GB_INTERFACE
Descriptive NameGb interface parameters in BSC
DescriptionThe parameter class contains parameters related to Gb interface.
2.51 Parameter class: 050REPORT_FORMING
Descriptive NameParameters of Report Forming Service
DescriptionThis parameter class includes parameters concerning Report Forming Service.
2.52 Parameter class: 051AAL2_SIG_PARAMETERS
Descriptive NameAAL type 2 signalling protocol parameter support information
DescriptionThis class contains information of which AAL type 2 signalling protocol parameters are supported.
2.53 Parameter class: 052SIP_SIGNALLING_PARAM
Descriptive NameSIP signalling specific parameters
DescriptionThis parameter class contains the Session Initiation Protocol (RFC 2543) parameters.
DN9979835 29
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
2.54 Parameter class: 053MSC_SERVER_PARAMETERS
Descriptive NameMSC Server specific parameters
DescriptionThe parameter class includes the parameters that are related to the MSC Server func-tionality of the standalone and integrated MSC Servers and Gateway Control Servers (GCS).
2.55 Parameter class: 054TCPIP_PARAMETERS
Descriptive NameTCP/IP parameters
DescriptionParameters related to TCP/IP protocols of DX200/IPA2800 platforms.
2.56 Parameter class: 055LCS_PARAMETERS
Descriptive NameLocation-related parameters
DescriptionThis class includes parameters related to Location Services (LCS).
2.57 Parameter class: 056STLOG_FACILITIES
Descriptive Nameparameters of stlog
DescriptionThe parameter class contains parameters related to collecting of service terminal com-mands.
2.58 Parameter class: 057IIN_ATTRIBUTES
Descriptive NameIIN attribute parameters
DescriptionAll IIN attribute parameters are described in this parameter class (FN1620).
30 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d8058075d099Confidential
PRFILE and FIFILE parameter classes
2.59 Parameter class: 058OAM_SECURITY
Descriptive NameO&M Security Parameters
DescriptionThis parameter class includes parameters concerning O&M security.
2.60 Parameter class: 059UMA_PARAMS
Descriptive Name2G-SGSN UMA Access related parameters
DescriptionThis parameter class contains parameters related to 2G-SGSN UMA access.
2.61 Parameter class: 060MANAGEMENT_PROTOCOLS
Descriptive NameManagement protocol parameters
DescriptionThis parameter class includes parameters that manage the use of management frag-ments of management protocols.
2.62 Parameter class: 061IN_ATTRIBUTES
Descriptive NameIN attribute parameters
DescriptionThis parameter class includes all IN attribute parameters (FN1620).
2.63 Parameter class: 062OLCM
Descriptive NameInterception related parameters
DescriptionThis parameter class includes all parameters that are related to interception (FN703, FN895, FN1745, SORM, and LAES)
DN9979835 31
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameter classes
Id:0900d8058075d099Confidential
2.64 Parameter class: 063SIEMENS_INAP
Descriptive NameSiemens_INAP
DescriptionThis parameter class contains the parameters related to Siemens INAP.
2.65 Parameter class: 064SERVICE_ATTRIBUTES
Descriptive NameService attribute parameters
DescriptionThis parameter class includes all Service attribute parameters (FN1841).
2.66 Parameter class: 065MGW_LICENCE_HANDLING
Descriptive NameMGW specific licence handling parameters
DescriptionThe parameter class includes the parameters that are related to the licensed features of the MGW.
2.67 Parameter class: 066WEB_SERVICE_ATTRIBUTES
Descriptive NameWeb Service Attributes
DescriptionThe PRFILE parameter class WEB_SERVICE_ATTRIBUTES is used to store PRFILE parameters related to WEB SERVICE AA.
2.68 Parameter class: 067AUX_PARAMETERS
Descriptive NameAuxiliary parameters
DescriptionThese parameters are planned to be used only in case of urgent PDCs when sack is not available.
32 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
3 PRFILE and FIFILE parameters
3.1 Parameter class 002 SYSTEM_FUNCT_CONFIGURDescriptive NameSystem functions configuration
DescriptionParameters in this class specify the functional configuration of each delivery, i.e. the functions that are included or excluded.
3.1.1 Parameter 002:0035 PRIMARY_RATE_INTERFACE
Descriptive nameExchange has possibility to primary rate interface connections
ModifiableNO
DescriptionThe parameter determines whether an ISDN primary rate interface can be connected to the network element or not.
Default value(s) G: 00H (FALSE) WX: 0FFH (TRUE)
Allowed values0FFH (TRUE) / 00H (FALSE)
Forbidden values
DependenceDependence on other parameters does not exist.
Feature227 - PRIMARY RATE ACCESS
347 - DPNSS
840 - 23B+D
Value Meaning
TRUE ISDN primary rate interface can be connected to the network element.
FALSE ISDN primary rate interface cannot be connected to the network element.
DN9979835 33
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
3.1.2 Parameter 002:0093 DOUBLE_BA_LIST
Descriptive nameDouble BCCH allocation list
ModifiableON/OFF
DescriptionThis parameter defines that the feature "Double BCCH Allocation List" is available only if the parameter value is PR_OP_T_DOUBLE_DA_LIST_C.
Default value(s)G: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
Feature -
3.1.3 Parameter 002:0094 TRANSM_EQ_MML_ENABLE
Descriptive nameBSS Transmission Equipment Handling MML enabling parameter
ModifiableON/OFF
DescriptionThis parameter defines the customer access control to the BSS transmission equipment handling MML (TREHAN).
Default value(s)G: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
34 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
Feature -
3.1.4 Parameter 002:0173 REMOTE_MMI
Descriptive nameRemote MMI flag
ModifiableON/OFF
DescriptionThis parameter defines whether the remote MMI facility is on or off.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
Feature -
3.1.5 Parameter 002:0188 T1_ENVIRONMENT
Descriptive nameT1 environment
ModifiableNO
DescriptionWith parameter value TRUE, the system functions in the T1 environment. All ETs have 24 time slots and a capacity of 1.544 Mbit/s.
Default value(s) G: 00H (FALSE)
Value Meaning
PR_OP_T_REMOTE_MMI_TRUE_C facility on
FALSE facility off
DN9979835 35
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
Allowed values0FFH (TRUE) / 00H (FALSE)
Forbidden values
DependenceDependence on other parameters does not exist.
Feature907 - MSCandHLR T1 INTERFACE
3.1.6 Parameter 002:0241 Q3_DX_ALARMS_FORW_ON
Descriptive nameQ3 DX alarm forwarding enabled
ModifiableYES
DescriptionThe parameter determines whether the Q3 interface is in use when the alarm events concerning a DX 200 based network element are transmitted to the OMC.
Default value(s)G: 0D D: 1D OX: 1D
Allowed values0D, 1D
Forbidden values
DependenceThe parameter is dependent on feature(s):
170 - CMIS (Q3 INTERFACE)
451 - APPL. FOR CMIS: ALARM INFORMATION TRANSFER
Feature170 - CMIS (Q3 INTERFACE)
Value Meaning
1D The alarm system sends the alarm events of the network element to the EHFRON program block to be forwarded to the Q3 interface.
0D The TXFSEB formats the alarm events into logical file OMCALARM. From the OMCALARM the alarms can be transferred to the OMC by using an OandM connection.
36 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
451 - APPL. FOR CMIS: ALARM INFORMATION TRANSFER
3.1.7 Parameter 002:0283 HR_FEATURE_IN_BSC
Descriptive nameHalf Rate feature installed in BSC
ModifiableON/OFF
DescriptionThis parameter defines whether the feature BSS5010 Half Rate is allowed in the BSC or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS5010 - HALF RATE
3.1.8 Parameter 002:0361 NORTH_AMERICAN_NUMBER
Descriptive nameNorth American (World Zone 1) numbering
ModifiableYES
DescriptionThe parameter defines whether the North American Numbering is in use.
Value Meaning
TRUE Feature is allowed.
FALSE Feature is not allowed.
Value Meaning
T Numbering is used.
F Numbering is not used.
DN9979835 37
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
Default value(s) G: 0 (F)
Allowed values1 (T) / 0 (F)
Forbidden values
DependenceDependence on other parameters does not exist.
Feature818 - WORLD ZONE 1 EQUAL ACCESS AND NUMBERING PLAN
3.1.9 Parameter 002:0371 AEC_USAGE
Descriptive nameUsage of Acoustic Echo Canceller
ModifiableON/OFF
DescriptionThis parameter defines whether acoustic echo canceller is allowed or not.
Default value(s)G: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS6142 - ACOUSTIC ECHO CANCELLATION
3.1.10 Parameter 002:0372 TFO_USAGE
Descriptive nameUse of Tandem-Free Operation
ModifiableON/OFF
38 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
DescriptionThis parameter defines the tandem-free operation.
Default value(s)G: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS6 -
3.1.11 Parameter 002:0380 ALLOW_OVER_16TRX
Descriptive nameCreating more than 16 TRXs in a BCSU
ModifiableON/OFF
DescriptionThis parameter defines that it is possible to create over 16 TRXs in a BCSU. Note that BSC SW also verifies that the BSC HW is able to handle more than 16 TRXs.
Default value(s)G: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS6009 - LARGE CAPACITY BSC
3.1.12 Parameter 002:0399 THREE_DIGIT_MNC
Descriptive nameThree digit MNC
DN9979835 39
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
ModifiableON/OFF
DescriptionThis parameter defines with the parameter value TRUE that the system works in an environment where MNC consists of three digits.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS7069 - ---
3.1.13 Parameter 002:0417 FH_IUO_USAGE
Descriptive nameFrequency hopping for intelligent underlay overlay usage.
ModifiableON/OFF
DescriptionThis parameter defines whether the Frequency Hopping for Intelligent Underlay Overlay option is allowed or not in the BSC.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
Feature9843 - ---
40 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
3.1.14 Parameter 002:0418 SMSCB_LAST_BLOCK_INFO
Descriptive nameSMS CB last block information used in BSC
ModifiableYES
DescriptionThe parameter defines whether the SMS CB last block information is used or not in the BSC. SMS Short Message Service CB Cell Broadcast Feature number: BSS6084.
Default value(s) SX: 00H (FALSE)
Allowed values0FFH (TRUE) / 00H (FALSE)
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS6084 - CELL BROADCAST ENHANCEMENTS
3.1.15 Parameter 002:0444 BTS_HW_DB_Q3_INT_IN_USE
Descriptive nameBTS HW Database Q3 Interface application is in use
ModifiableON/OFF
DescriptionThis parameter defines that events that the BTS HW Database object class emits to the Q3 interface are allowed to be sent to the manager. The Q3 interface is an object-oriented management interface between a network element and a network manage-ment element.
Default value(s)SX:
Allowed valuesTRUE / FALSE
Forbidden values
DN9979835 41
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
DependenceDependence on other parameters does not exist.
FeatureBSS7001 - ---
3.1.16 Parameter 002:0461 BIN_HEADER_TYPE
Descriptive nameBinary report header type
ModifiableYES
DescriptionThe parameter determines what kind of header is added into binaryreports. The NMS, for example, uses a binary report header for the identification of these reports. If the parameter value is changed, NMS may not recognise the reports.
Default value(s)G: 0D M: 1D S: 1D W1: 1D
Allowed values0D, 1D
Forbidden values
DependenceDependence on other parameters does not exist.
Feature30095 - REPORT FORMING SERVICE
3.1.17 Parameter 002:0466 FLEX_MAIO_USAGE
Descriptive nameFlexible maio management usage.
ModifiableON/OFF
Value Meaning
0D Header is of a shorter format and does not contain block length.
1D Header is of a longer format and contains block length.
42 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
DescriptionThis parameter defines whether the Flexible Maio management option is allowed or not in the BSC.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
Feature9807 - FLEXIBLE MAIO MANAGEMENT
3.1.18 Parameter 002:0470 SMSCB_INDEPEN_MULTIPAGE
Descriptive nameSMS CB pages considered independent by the BSC
ModifiableYES
DescriptionThe parameter defines whether the pages of multipage SMS CB message are consid-ered as independent or not by the BSC scheduling algorithm. If the pages are consid-ered as independent it allows another CB message broadcast to the mobile between the pages of a multipage message. SMS Short Message Service CB Cell Broadcast.
Default value(s) SX: 00H (FALSE)
Allowed values0FFH (TRUE) / 00H (FALSE)
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS7002 - CELL BROADCAST INTERFACE TO CELL BROADCAST CENTRE
DN9979835 43
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
3.1.19 Parameter 002:0500 ALLOW_48_OR_64_TRX
Descriptive nameLarger Capacity BSC: Creation of 48 TRXs (BSCE) and 64 TRXs (BSC2E/A ) in a BCSU
ModifiableON/OFF
DescriptionThis parameter defines that it is possible to create more than 16 TRXs in a BCSU. The maximum TRX number in a BCSU depends on the BSC type. With the BSCE the maximum number is 48 TRXs in a BCSU and with the BSC2E/A it is 64 TRXs in a BCSU.
Default value(s)G: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS8129 - LARGER CAPACITY BSC
3.1.20 Parameter 002:0511 ABIS_AUTOCONF_IN_USE
Descriptive nameBSC Support for Autoconfiguration: Abis autoconfiguration in use
ModifiableNO
DescriptionThe parameter defines whether the operator has the abis autoconfiguration feature in use. If the value is TRUE, operator has the abis autoconfiguration feature in use in the BSC.
Default value(s)SX: FALSE
Allowed valuesFALSE / PR_OP_T_AUTOCONF_IN_USE_C
Forbidden values
44 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
DependenceDependence on other parameters does not exist.
FeatureBSS8125 - BSC SUPPORT FOR AUTOCONFIGURATION
3.1.21 Parameter 002:0558 MS_CAP_IND_USAGE
Descriptive nameAuthorisation of the use of the MS Capability Indication measurement
ModifiableON/OFF
DescriptionThis parameter defines whether use of the MS Capability Indication measurement is allowed or not in the BSC.
Default value(s): FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS9018 - MS CAPABILITY INDICATION
3.1.22 Parameter 002:0602 TRE_SW_DL_MC_ADDRESS
Descriptive nameTransmission equipment software download multicast address
ModifiableYES
Value Meaning
TRUE Use of MS Capability Indication measurement is allowed
FALSE Use of MS Capability Indication measurement is not allowed
DN9979835 45
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
DescriptionThe parameter defines the Q1 implemented transmission equipment multicast address which is used when transmission equipment software is downloaded with multicast mode.
Default value(s)SX: 4050D
Allowed values4050D-4059D
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS9023 - SW DL SUPPORT FOR METROSITE TRANSMISSION EQUIPMENT
3.1.23 Parameter 002:0623 NOISE_SUPPRESSION_USAGE
Descriptive nameNoise Suppression, use of
ModifiableON/OFF
DescriptionThis parameter defines whether noise suppression is allowed or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS9069 - NOISE SUPPRESSION
3.1.24 Parameter 002:0626 DAC_USAGE
Descriptive nameDefined Adjacent Cell measurement, use of
46 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
ModifiableON/OFF
DescriptionThe parameter determines whether use of the optional Defined Adjacent Cell measure-ment is allowed in the BSS or not. If the customer has the feature, he can activate or deactivate it by changing the parameter value. Possible values are ON and OFF.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10072 - AUTOMATED FREQUENCY PLANNING
3.1.25 Parameter 002:0628 FER_USAGE
Descriptive nameFER measurement
ModifiableON/OFF
DescriptionThe parameter determines whether use of the optional FER measurement is allowed in the BSS or not. If the customer has the feature, he can activate/deactivate it by changing the parameter value, the possible values are ON/OFF.
Default value(s)SX: FALSE
Value Meaning
ON The Defined Adjacent Cell Measurement feature is active.
OFF The Defined Adjacent Cell Measurement is inactive. If the customer has bought the feature, this is the default value.
Value Meaning
ON The FER measurement feature is active.
OFF The FER measurement feature is inactive. If the customer has bought the feature, this is the default value.
DN9979835 47
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10022 - FER MEASUREMENT
3.1.26 Parameter 002:0643 REV_HUNT_USED
Descriptive nameReversed hunting
ModifiableON/OFF
DescriptionThe parameter determines whether the optional feature Reversed hunting is allowed in the BSS or not. If the customer has the feature, it can be activated or deactivated by changing the value of the parameter. Possible values are ON and OFF.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10005 - REVERSED HUNTING
3.1.27 Parameter 002:0644 DYN_ABIS_IN_USE
Descriptive nameDynamic Abis allocation in use
Value Meaning
ON The Reversed hunting feature is active.
OFF The Reversed hunting feature is inactive. This is the default value.
48 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
ModifiableON/OFF
DescriptionThis parameter defines whether the dynamic Abis feature is in use or not in the BSC.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10045 - DYNAMIC ABIS
3.1.28 Parameter 002:0654 PBS_USAGE
Descriptive namePosition Based Services
ModifiableON/OFF
DescriptionThe Position Based Services feature is for locating valid mobile equipment. The param-eter determines whether use of the optional Position Base Services is allowed in the BSS or not. Possible values are ON and OFF.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Value Meaning
PR_OP_T_DYN_ABIS_IN_USE_C The feature is in use.
FALSE The feature is not in use.
Value Meaning
ON Position Based Services is activated.
OFF Position Based Services is deactivated. This is the default value.
DN9979835 49
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10012 - POSITION BASED SERVICES (PBS) IN BSC
3.1.29 Parameter 002:0664 COMMON_BCCH_EGSM900
Descriptive nameCOMMON BCCH EGSM900
ModifiableON/OFF
DescriptionThis parameter defines whether SEG can have TRXs from the EGSM900 band or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10016 - COMMON BCCH and MULTI BCF
3.1.30 Parameter 002:0665 SEGMENT_USAGE
Descriptive nameSEGMENT USAGE
ModifiableON/OFF
Value Meaning
TRUE A cell can have TRXs from the EGSM900 band. So a SEG object can include BTS objects from the EGSM900 band.
FALSE A cell cannot have TRXs from the EGSM900 band.
50 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
DescriptionThis parameter defines whether SEG is shown to the user or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10016 - COMMON BCCH and MULTI BCF
3.1.31 Parameter 002:0666 COMMON_BCCH_GSM900
Descriptive nameCOMMON BCCH GSM900
ModifiableON/OFF
DescriptionThis parameter defines whether SEG can have TRXs from the GSM900 band or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
Value Meaning
TRUE SEG is shown to the user.
FALSE SEG is not shown to the user.
Value Meaning
TRUE A cell can have TRXs from the PGSM900 band. So a SEG object can include BTS objects from the GSM900 band.
FALSE A cell cannot have TRXs from the PGSM900 band.
DN9979835 51
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
DependenceDependence on other parameters does not exist.
FeatureBSS10016 - COMMON BCCH
3.1.32 Parameter 002:0667 COMMON_BCCH_GSM1800
Descriptive nameCOMMON BCCH GSM1800
ModifiableON/OFF
DescriptionThis parameter defines whether SEG can have TRXs from the GSM1800 band or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10016 - COMMON BCCH
3.1.33 Parameter 002:0668 MULTI_BCF
Descriptive nameMULTI BCF
ModifiableON/OFF
DescriptionThis parameter defines whether a cell can have TRXs from different base stations (BCF objects).
Value Meaning
TRUE A cell can have TRXs from the GSM1800 band. So a SEG object can include BTS objects from the GSM1800 band.
FALSE A cell cannot have TRXs from the GSM1800 band.
52 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10046 - MULTI BCF
3.1.34 Parameter 002:0693 FIRST_FREE_NUMBERED_CGR
Descriptive nameFirst allowed circuit group number for free numbered circuit groups.
ModifiableYES
DescriptionThe parameter defines the first allowed circuit group number for circuit groups to which system allocates circuit group numbers.
Default value(s)GX: 1D SX: 300D
Allowed values1D - 2048D
Forbidden values
DependenceDependence on other parameters does not exist.
Feature30581 - ROUTING ARCHITECTURE
Value Meaning
TRUE A cell can have TRXs from different base stations. So a SEG object can include BTS objects of different base stations (BCF objects).
FALSE A cell cannot have TRXs from different base stations. So a SEG object cannot include BTS objects of differ-ent base stations (BCF objects).
DN9979835 53
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
3.1.35 Parameter 002:0701 S9_LOCATION_SYSTEM
Descriptive nameCell ID, TA and RxLevel delivery to Standalone SMLC
ModifiableON/OFF
DescriptionThe parameter determines whether use of the optional Cell ID, TA and RxLevel to S/O SMLC(Serving Mobile Location Center) is allowed in the BSS or not. If the customer has the feature, he can activate/deactivate it by changing the parameter value. Possible values are ON/OFF.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS9089 - BSC SUPPORT FOR MCATCH 1.0 AND 1.5
3.1.36 Parameter 002:0702 TTY_USAGE
Descriptive nameText Telephone (TTY)
ModifiableON/OFF
DescriptionThe parameter defines whether Text Telephone (TTY) support is enabled or not. If TTY support is enabled Cellular Text Telephone Modem (CTM) is used in the Transcoder Submultiplexer (TCSM2).
Default value(s)SX: FALSE
Value Meaning
ON Cell ID, TA and RxLevel delivery service is activated
OFF Cell ID, TA and RxLevel delivery service is deactivated_ this is the default value
54 DN9979835
PRFILE and FIFILE Parameter List
Id:0900d805808a9388Confidential
PRFILE and FIFILE parameters
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on other parameters does not exist.
FeatureBSS10112 - TEXT TELEPHONY (TTY) FOR US MARKETS
3.1.37 Parameter 002:0711 NEMU_IS_PRESENT
Descriptive nameNEMU is present in the network element
ModifiableYES
DescriptionWhen the parameter value is T (True, 1), NEMU unit is present in the network element.
Default value(s) GX: 0 (F)
Allowed values1 (T) / 0 (F)
Forbidden values
DependenceDependence on other parameters does not exist.
Feature30881 - EXTERNAL MESSAGE TRANSFER
3.1.38 Parameter 002:0733 COMMON_BCCH_GSM800
Descriptive nameCOMMON BCCH GSM800
ModifiableON/OFF
Value Meaning
0 NEMU is not present in Network Element
1 NEMUis present in Network Element
DN9979835 55
PRFILE and FIFILE Parameter List PRFILE and FIFILE parameters
Id:0900d805808a9388Confidential
DescriptionThis parameter defines whether the Common BCCH Segment can have TRXs from the GSM800 band or not.
Default value(s)SX: FALSE
Allowed valuesTRUE / FALSE
Forbidden values
DependenceDependence on othe