90
C 1 Pneumatic Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatic Pressure Sensors Section C

Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Embed Size (px)

Citation preview

Page 1: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

C

1

PneumaticParker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure Sensors

Section C

pneu

air

e

Page 2: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic2 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic Control ComponentsPressure Sensors

Catalog 0802-2/USA

Notes

pneu

air

e

Page 3: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

3 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic Control ComponentsPressure Sensors

Catalog 0802-2/USA

Index

Pressure Output Maximum Hysteresis

Output PageRange Type

Media IP Output ModeSetting

DisplayNumberRating Adjustment

MPS-1 0 to 145 PSI(1) NPN / PNP

Air, Variable,0 to -30inHG

With AnalogNon-Corrosive 65 3 to Trim Pot — 4 - 7

0 to 14 PSI Gas 20% F.S.

MPS-20 to -30 inHg

Air, Variable, Push LED Display

-14.7 to 72.5 PSI(2) NPN / PNP Non-Corrosive 65

100%F.S. Button (Red)8 - 13

Gas

MVS-2010 to -30 inHg Air, Variable, Push LED Display-14.7 to 72.5 PSI

(1) NPN / PNP Non-Corrosive 40 100%F.S. Button (Red)

14 - 21 Gas

MPS-3 0 to 145 PSIAir,0 to -30inHG (2) NPN / PNP

Non-Corrosive 65

Variable, Push LED Display22 - 270 to 14 PSI Analog Option

Gas 100%F.S. Button (Red)

-14.7 to 72.5 PSI

MPS-3Stainless Steel Fluid,0 to 145 PSI (2) NPN / PNP Non-Corrosive

65Variable, Push LED Display

28 - 330 to -30inHG Analog Option to 316L or 100%F.S. Button (Red)-14.7 to 72.5 PSI630 SUS

MPS-31 0 to 145 PSI Air,Variable, Push LED Display0 to -30inHG (1) NPN / PNP Non-Corrosive 40100%F.S. Button (Red / Green)

34 - 39-14.7 to 72.5 PSI Analog Option Gas

MPS-4-8 to 8 inH2O (2) NPN / PNP

Air, Variable, Push LED Display

0 to -29.8 inHg Analog OptionNon-Corrosive 40

100%F.S. Button (Red)40 - 45

Gas

MPS-5 Fluid,0 to 145 PSI

AnalogNon-Corrosive

65 — — — 46 - 500 to -30inHG to 316L or630 SUS

MPS-60 to 145 PSI (1) NPN / PNP Air,0 to -30inHG

or (1) AnalogNon-Corrosive 40 — Trim Pot — 52 - 56

0 to 14.7 PSI Gas

MPS-7Remote Panel: Use

71: (2) NPN/PNP Variable, Push LED Display

with MPS-5,6,8Analog Option — 40

100% F.S. Button (Red)58 - 65

74: (4) NPN/PNP

MPS-80 to -30inHG (1) NPN / PNP

Air, Fixed,

-14.7 to 72.5 PSI or (1) AnalogNon-Corrosive 40

< 2% F.S.Trim Pot — 66 - 69

Gas

MPS-9 Air,0 to -30inHG (1) NPN / PNP Non-Corrosive 65 Variable, Push LED Display 70 - 75-14.7 to 72.5 PSI with AnalogGas

100% F.S. Button (Red)

SCPSD -14.7 PSI to 250 PSI0 to 1000 PSI (1 or 2) PNP Non- Variable, Push LED Display0 to 3000 PSI Analog Option Corrosive 67 100% F.S. Button (Red) 76 - 810 to 5000 PSI to 316L SUS0 to 9000 PSI

Accessories 82 - 83Technical Information 84 - 86Programming Symbols Legend 87Glossary 88 - 90

pneu

air

e

Page 4: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic4 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-1 Basic

Catalog 0802-2/USA

Features

Features• Pressure Ranges:

Positive Pressure .................0 to 145 PSIVacuum Pressure ............... 0 to -30 inHgLow Pressure ......................0 to 14.7 PSI

• Sensor Outputs1 Normally Open NPN or PNP OpenCollector Transistor Output;30VDC, 125mA

1 Analog 1 to 5 VDC

• Switch Output Adjusted withPotentiometer 3-Turn Trimmer

• Switch Hysteresis Adjusted withPotentiometer 3/4 Turn Trimmer

• Output Response Time Less Than2.5 Milliseconds

• CE Marked

• Air and Non-Corrosive Gases

MPS-1

Output Modes

hH

off off

0

-30 in Hg

on on

The MPS-1 Series Sensor has two outputs,one open NPN or PNP switch output and oneanalog output. The Hysteresis Range (h)controls the output signal below the SwitchPoint (H).The Pressure Output Signal is a 3 turntrimmer that sets the switch point of theoutput. The hysteresis adjustment is a 3/4turn trimmer to control the output signal 3 to20% below the pressure output signal. TheAnalog Output is a 1 to 5 VDC signalcalibrated to the pressure scale of the sensor.

Switch Output

5

00 Max. Rating

1

Pressure

Ou

tpu

t (V

olt

s)

Analog Output

Analog Output

Model Number Output Pressure Range

MPS-P1N-NC NPN 0 to 145 PSI

MPS-P1N-PC PNP 0 to 145 PSI

MPS-V1N-NC NPN 0 to -30 inHg

MPS-V1N-PC PNP 0 to -30 inHg

MPS-V1E-NC NPN 0 to -30 inHg

MPS-V1E-PC PNP 0 to -30 inHg

MPS-P1E-NC NPN 0 to 145 PSI

MPS-P1E-PC PNP 0 to 145 PSI

pneu

air

e

Page 5: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

5 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Ordering Information, SpecificationsPressure SensorsMPS-1 Basic

MPS - V 1 N - P C

Pressure RangeV 0 to -30 inHgL 0 to 14.7 PSIP 0 to 145 PSI

Port SizeN 1/8" NPT / M5FR 1/8" BSPT / M5FG 1/8" BSPP / M5FE Flange / M5F

CircuitN NPN Sinking OutputP PNP Sourcing Output

Electrical ConnectorC M8 4-Pin

Model Number IndexBold Items Are Stocked

MPS-L1N-PC MPS-V1E-PC

Media Air and Non-Corrosive Gases

Pressure Port N: 1/8" NPT, R: 1/8" BSPT, G: 1/8" BSPP, E: Flange Mount with M5 Female

Proof Pressure V: 72.5 PSI, L: 72.5 PSI, P: 217.5 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection 4-Pin, M8 Connector with Built-in LED

Power Supply 10.8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Analog Output 1 to 5 VDC ±0.04, Accuracy Linear 0.5% F.S.

Switch Output N.O., Switch Output Mode with Hysteresis Adjustment

Output Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor 30VAC, 80mA

Switch Output Setting H 3-Turn Trimmer

Hysteresis Setting h 3/4-Turn Trimmer (3 to 20% of Switch Output Setting)

Response Time < 2.5ms

Repeatability ±1% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP65 or IP40, CE Marked, EMC Rating: EN55011 Class B, EN50082-2

Current Consumption < 20mA

Spike Protection 400 VP, 1 µs

Dielectric Strength 1000VAC, 1min.

Insulation Resistance > 100M ohms at 500VDC

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 100 G, XYZ

Material Housing: Polycarbonate, Pressure Port: Zinc Die-cast

Mass 1.06 oz. (30g)

SpecificationsMounting Bracket for MPS-V1E Included.

pneu

air

e

Page 6: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic6 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-1 Basic

Catalog 0802-2/USA

Technical Information

Output Setting

H

S

1

2

4

3

H

S

1

2

4

3

NPN (Sinking) PNP (Sourcing)

Switch Output SettingThe Switch Point of the output signal is adjusted with a3-turn potentiometer trimmer (S). To set the switch pointpressure, rotate the trimmer clockwise to raise the switchpressure and rotate the trimmer counter clockwise to lowerthe switch pressure.

S

H

S

H

Hysteresis SettingThe Hysteresis setting is a 3/4 - turn potentiometer trimmerwith a range of 3% to 20% below the switch point (S).Rotate the Hysteresis trimmer (H) clockwise to increase theHysteresis range and rotate the trimmer counter clockwiseto lower the Hysteresis range (h). A separate pressuregauge is necessary to accurately adjust these values.For best results, set the switch point (H) of the output signalbefore adjusting the hysteresis range. For fine tuning thehysteresis range, re-adjust the switch point (S) of the outputsignal.

Internal Circuit

Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install using the metal mounting base.• To achieve IP65 rating, connect the o-ring and barb to a

normal environment with a 2mm I. D. tube and install screwas shown .

CautionsThe MPS-1 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.Potentiometer for the Switch Point Pressure and HysteresisRange is sensitive. Excessive force or exceeding the limits ofthe trimmers may cause damage.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

!

S

H

BarbCoupling

O-Ring

Screw-INCLUDED-

Pin #1 Brown: 24VDC2 White: Analog 1 to 5VDC Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

2

1

4

3

Sensor Pin Out Lead Wiring

Brown V+

White Analog 1 to 5 VDC

Blue 0V

Black NPN / PNP Output

pneu

air

e

Page 7: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

7 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-1 Basic

Catalog 0802-2/USA

Dimensions

Dimensions

.62(15,7)

.31(8)

.35(9)

1.77(45)

.83(21,2)

.75(19)

.51(13)

.31(8)

M8

SH

M5Fx5

M5Fx5

M4F2 Places

M3Fx54 Places

G1/8M

LED

.35(9)

.35(9)

.13(3,2)

.28(7,2)

1.30(33)

.06(1,5)

.39(10)

1.73(44)

LED

.62(15,7)

M3Fx42 Places

M3Fx42 Places

.83(21,2)

.97(24,7)M8

SH

.63(16)

.29(7,4)

1.73(44)

1.22(31)

1.18(30)

.75(19)

.31(8)

.031(,8)

.17 (4.5) Dia.4 Places

N, R, G1/8" MaleM8, 4-Pin

E,FlangeMountM8, 4-Pin

.196 (5) Dia .38 (9,7) Dia

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia .38 (9,7) Dia

16.40 ft(5m)

1.26(32)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

AccessoriesCables

ACCMPS-1EFlange Bracketfor V1E Type(Included withE Option)

pneu

air

e

Page 8: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic8 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-2 Versatile

Catalog 0802-2/USA

Features

Features• Pressure Ranges:

Vacuum Pressure ............... 0 to -30 inHgCompound Pressure .... -14.7 to 72.5 PSI

• Sensor Outputs:2 NPN or PNP Open Collector TransistorOutput , 30VDC, 125mA

• Switch Point and High-low Programming

• 4 Selectable Units of Measure(mmHg, -bar, -kPa, inHg)(kgf/cm2, PSI, bar, kPa)

• Automatic Teach Mode

• Auto Surveillance for Peak PressureMonitoring

• Output Response Time Less Than2.0 Milliseconds

• CE Marked

• Air and Non-Corrosive Gases

• Error Message

MPS-2

Output Modes

The MPS-2 Series Sensor has twoindependent NPN or PNP open collectoroutput signals. The Switch Output Mode has aswitch point programmed by the user at aspecified pressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the Switch Point (H).

The Window Comparator Mode provides twoSwitchpoint Settings (A) and (b) that controlthe output signals (NPN / PNP) between twopressures. This is referred to as the “High /Low” setting.

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

Switch Output

Window Comparator Output

Model Number Output Pressure Range

MPS-V2N-NC NPN 0 to -30 inHg

MPS-V2N-PC PNP 0 to -30 inHg

MPS-R2N-NC NPN -14.7 to 72 PSI

MPS-R2N-PC PNP -14.7 to 72 PSI

pneu

air

e

Page 9: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

9 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Ordering Information, SpecificationsPressure SensorsMPS-2 Versatile

MPS - V 2 N - P C –

Pressure RangeV 0 to -30 inHgR -14.7 PSI to

72 PSI

Port SizeN 1/8" NPTR 1/8" BSPTG 1/8" BSPPM5 M5 FemaleC Ejector

CircuitN NPN Sinking

OutputP PNP Sourcing

Output

Electrical ConnectorC M8 4-PinG Grommet (2m)

Din RailBlank WithoutR* With* M5 Port Size

Only

MPS-R2M5-NGRMPS-V2N-PC

Pressure Range Vacuum (V) Compound (R)

bar: 0.001 bar: 0.01Units of Measure kPa: 0.1 kPa: 1

Display Resolution mmHg: 1 kgf/cm2: 0.01inHg: 0.1 PSI: 0.1

Media Air and Non-Corrosive Gases

Pressure Port N: 1/8" NPT, R: 1/8" BSPT, G: 1/8" BSPP, M5: M5 Female

Proof Pressure V: 72.5 PSI, R: 116.0 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector, G: 2m Grommet Open Lead

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LED

Display Refresh 0.1 to 3.0 sec. (Factory set at 0.1)

Output Circuit NPN (Sinking) or PNP (Sourcing) Output, Open Collector Transistor 30VDC, 125mA

Switch Output 2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator

Output Modes Hysteresis or Window Comparator

Response Time < 2ms, with Programmable Increments 32, 128, 1024ms

Repeatability ± 0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP65 or IP40, CE Marked, EMC-EN55011 Class B, EN 50082-2

Insulation Resistance > 100M ohms at 500VDC

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Housing: Polycarbonate, Pressure Port: Zinc Die-cast

Mass 1.58 oz. (45g)

Specifications

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 10: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic10 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-2 Versatile

Catalog 0802-2/USA

Technical Information

NPN 1

2

4

3

PNP 1

2

4

3

NPN Sinking PNP Sourcing

Internal Circuit

21

21

BarbCouplingO-Ring

Ambient AirInlet Port

–INCLUDED–

CautionsThe MPS-2 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install as shown using the metal mounting base.• To achieve IP65 rating, connect the o-ring and barb as

shown to a normal environment with a 2mm I. D. tube.

Error MessagesDisplay Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

Er2 Auto Teach Mode Error Restart Function

CE1 Over current of Output 1 Load current exceeds

CE2 Over current of Output 2 maximum 125mA.

FFF Applied pressure exceeds Apply pressures within–FF pressure range the rating of the sensor

2

1

4

3

Pin #1 Brown: 24VDC2 White: NPN / PNP Open Collector Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Sensor Pin Out Lead Wiring

Brown V+

White NPN / PNP Output

Blue 0V

Black NPN / PNP Output

pneu

air

e

Page 11: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

11 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

.38(10)

.63(16)

.31(8)

.35(9)

2.32(59)

.98 (25)

.55 (14).22

(5,7)

M5Fx.8 M3Fx4 Vent Port

M3Fx4 Vent PortM5Fx.8

G1/8M

1.73(44)

.49 (12,5)

2 1

.63(16)2.69

(88)

.98 (25)

.55 (14).22

(5,7)

.49 (12,5)

2 1

2.40(61)

.15 (3,8)

.35(9)

M3Fx4 Vent Port

.63(16)

2.32(59)

.98 (25)

.55 (14).22

(5,7)

.49 (12,5)

.14 (3,5)

.12(3)

2 1

1.73(44)

DimensionsN, R, G,1/8" MaleM8, 4-Pin

DIN RailM5 FemaleGrommet

Pressure SensorsMPS-2 Versatile

Catalog 0802-2/USA

Dimensions

Ejector

pneu

air

e

Page 12: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic12 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMPS-2 Versatile

Output Set Openor Closed SelectingUnits of MeasureEasy Mode Activation

Output Mode 1Hysteresis orWindowComparator

Output Mode 2Hysteresis orWindowComparator

Output 1 Setting Output 2 Setting Automatic Teach Mode& Auto Surveillance

Display RefreshSettings / OutputResponse TimeInterval

Lock Unlock

Special DisplayFeatures

ZeroReset

Display Peak ValueBottom Value orTheir Difference

VacuumCycle

ReleaseCycle

PeakValue

BottomValue

1 2 3

4 5 6

7 8 9

1011 12

2 1

2 1

2 12 1

2 1

2 1

2 1

2 1 2 1 2 1 2 1

2 1

2 1

2 1

2 1

Press 6x

Press for 3 Seconds

Press 1x

HoldPress 1x

Press 7x Press 8x

Press 1x

Press 3x

Press 2x

Press 5x

Press 4x

HoldPress

HoldPress Press 1x

Window ComparatorMode

Window ComparatorMode

HysteresisMode

HysteresisMode

Low Low

High High

See page 87 for Symbol Explanation

pneu

air

e

Page 13: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

13 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

MPS-ACCK4Din Rail

Accessories

.38(10)

.53(13)

2.69(88)

Cables

Catalog 0802-2/USA

AccessoriesPressure SensorsMPS-2 Versatile

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

pneu

air

e

Page 14: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic14 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Basic PLC System PLC System with 201 Sensor

PLC

IN

OUT

- +

Vacuum PilotBlow-Off Pilot

Sensor Output 2Sensor Output 1

( V )

( B )

PLC

IN

OUT

- +Sensor

Vacuum Part Present Output

( V )

Pressure SensorsMVS-201 Genius

Catalog 0802-2/USA

Features

Features• Pressure Range:

Compound Pressure .... -14.7 to 72.5 PSI

• Time Controlled Sensor

• Intelligent Simple 4-wire System

• Eliminate I/O for Release Valve

• 2 Functions with One Rung of Code

• Automatic Timer (0-9.9 sec.) Function bySensor Control Driver for VacuumGenerating and Release Valves

• Peak Value Preventative MaintenanceConfirmation

• Response Time Less Than 2 Milliseconds

• CE Marked

MVS-201

Output Modes

hH

off off

0

-30 in Hg

on on

Switch Output

The MVS-201 Series Sensor has oneindependent NPN or PNP open collectoroutput signal. The Switch Output Mode has aswitch point programmed by the user at aspecific pressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the Switch Point (H).

The MVS-201 is a winning combination with the MC2,CVR-2, and CVK vacuum generators. The MVS-201automatically provides an output signal for the blow-offfunction without the need of an additional output fromthe PLC. Begin the vacuum cycle with an input signalfrom the PLC to the “201” sensor. The “201” sensorhas one output NPN or PNP for vacuum confirmationand a control output that interfaces directly with theblow-off release pilot valve. With programmable timecontrol features and a special chip driver, the sensorautomatically activates the blow-off release when the

NPN or PNP vacuum signal from the PLC isdiscontinued. This eliminates, THE PREVIOUSLYREQUIRED, PLC output to activate the blow-offrelease This new technology eliminates PLC outputrequirements by 50% and reduces installation to asimple 4 wire system by wiring the sensor only. Thereare 3 modes of operation for various applications.The output response time of the sensor is less than2.5 msec. Peak limit prevention maintenance featureis automatically recorded internally.

pneu

air

e

Page 15: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

15 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Ordering Information, SpecificationsPressure SensorsMVS-201 Genius

MVS - 201 - P C —

Output CircuitN NPN Sinking

OutputP PNP Sourcing

Output

Cable ConnectorC 4-Pin M8 Connector

Pressure Range Compound (R)

bar: 0.01Units of Measure kPa: 1

Display Resolution kgf/cm2: 0.01PSI: 0.1

Media Non-Lubricated Air and Non-Corrosive Gases

Proof Pressure 116.0 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LED

Display Frequency 5Hz

Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor

Digital Output Individually Selectable N.O. or N.C., max 125mA, 30V, with Overcurrent Protection

Mode OP1, OP2, OP3 Hysteresis: 0 to 100% of Switch Point

Response Time < 2ms

Repeatability ± 0.3% F.S.

Thermal Error ±0.2% F.S. in Temperature Range: 32 to 122°F (0 to 50°C)

General Protection IP40, CE Marked, EMC-EN55011 Class B, EN50082-1

Current Consumption < 45mA, < 25mA When Utilizing Screen Saver Option

Spike Protection 350 Vp, 1, µs

Dielectric Strength 1000 VAC 1 min.

Insulation Resistance > 100M ohms at 500VDC

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Body: Polycarbonate

Mass 1.7 oz. (45g)

Specifications

Model Number IndexBold Items Are Stocked

Input CircuitBlank NPN Sinking

InputP PNP Sourcing

Input

Note:Output Circuit provides vacuum and blow-off confirmation signal(Input Signal to PLC).Input Circuit controls vacuum solenoid valve(Output Signal from PLC).

pneu

air

e

Page 16: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic16 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMVS-201 Genius

Catalog 0802-2/USA

Technical Information

NPN Sinking PNP Sourcing

Wiring Diagram

CautionsThe MVS-201 Pressure Sensor is designed to monitorpressure and is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.

2

1

1234

4

3

Sensor MalePin Out

Error MessagesDisplay Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

CE1 Over current of Output 1 Load current exceeds

FFF Applied pressure exceeds Apply pressures within–FF pressure range the rating of the sensor

M8 Pin #1 Brown: 24VDC2 White: Input; NPN (0VDC) / PNP (24VDC)3 Blue: 0VDC4 Black: Output; NPN / PNP Open Collector Output

201 Pin #1 Red: Vacuum Solenoid Valve + V2 Black: Gnd3 Red: Blow-Off Solenoid Valve + V4 Black: Gnd

Max. 125mA

Max. 125mA

or TR or TR

Mai

n C

ircu

it

Mai

n C

ircu

it

(Brown) +V (DC 10.8 to 30V) (Brown) +V (DC 10.8 to 30V)

(Black) OUT 1

(Blue) OV

1 (Red)

2 (Black)

4 (Black)

3 (Red)

(White) Suction/Break Command Input

(Black) OUT 1

(Blue) OV

(White) Suction/Break Command Input

Digital IN Digital IN

Load

Lo

ad

VacuumSolenoid

Valve

Break Solenoid

Valve

+

-

+

-

+

-

+

-

VacuumSolenoid

Valve

Break Solenoid

Valve

+

-

+

-

Connector for connection of solenoid valveConnection is finished when Convum is installed

1 (Red)

2 (Black)

4 (Black)

3 (Red)

Connector for connection of solenoid valveConnection is finished when Convum is installed

Internal Circuit

pneu

air

e

Page 17: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

17 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

.63(16)

.14(3.5)

.35(9)

2.19(55.5)

.98(25)

.59(15)

1.73(44)

.12(3)

2 1

.20(5)

.35(9)

.63(16)

.98(25)

.50(12.7)

Dimensions

M8, 4-Pin

Pressure SensorsMVS-201 Genius

Catalog 0802-2/USA

Dimensions

pneu

air

e

Page 18: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic18 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMVS-201 Genius

Operating ModesDescription of operation modes and terms on page 20.

Timer Mode OP1“Air Conservation / Vacuum Valve Timer”This Vacuum valve control with the use of timing featuresconserves air consumption via the vacuum generator non-return check valve and sensor hysteresis function. Vacuumtime (t1) can be used to control the vacuum valve for aspecific length of time (0.0-9.9 sec.) after output 1 vacuumlevel is reached. The vacuum timing function (t1) will removethe signal from the sensor to the vacuum valve allowing thegenerator check valve system to conserve air consumptionand vacuum. The vacuum valve will re-open for the samelength of time (t1) when the pressure level drops to thehysteresis setting (h-v). The operation will continue until theinput signal is stopped. Optional delay timer between vacuum/ blow-off (t2) and blow-off (bt) timer is available. Afterselecting OP1, set bt, t1, and t2 values by using arrow “UP”and “DOWN” keys. To bypass any of these timing functionoperations, simply enter 0.00 seconds and the sensor willautomatically proceed to the next function.

PSI

inHg

(P-v) Peak ValueON (H-v) Vacuum

OFF (h-v)

OFF (h-d)

ON (H-d) Blow-Off

InputSignal

ONOFF

ONOFF

ONOFF

ONOFF

Blow-OffSolenoid

VacuumSolenoid

Sensor Output 1

T1: Vacuum TimerT2: Blow-Off Delay TimerBT: Blow-Off Timer

Mode: OP1 "Air Conservation / Timer

T1

ut

T1

dt

T2 BT

InputSignal

ONOFF

ONOFF

ONOFF

ONOFF

Blow-OffSolenoid

VacuumSolenoid

T1: Vacuum TimerT2: Blow-Off Delay TimerBT: Blow-Off Timer

PSI

inHg

(P-v) Peak ValueON (H-v) Vacuum

OFF (h-v)

OFF (h-d)

ON (H-d) Blow-Off

BTT2

T1

Mode: OP2 "Vacuum Timer Option"

ut dt

Sensor Output 1

Timer Mode OP2“Vacuum Valve Timer”This mode is ideal for use with CONVUM generators withoutcheck valves. Vacuum timer (t1) can be used to control thevacuum for a specific length of time (0.00 – 9.9sec.) afteroutput 1 is reached. Optional delay timer between vacuum /blow-off (t2) and blow-off (bt) timer is available. Afterselecting OP2, set bt, t1, and t2 values by using arrow “UP”and “DOWN” keys. To bypass any of these timing functionoperations, simply enter 0.00 seconds and the sensor willautomatically proceed to the next function.

Note:Output Circuit provides vacuum and blow-off confirmation signal(Input Signal to PLC).Input Circuit controls vacuum solenoid valve(Output Signal from PLC).

pneu

air

e

Page 19: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

19 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

InputSignal

ONOFF

ONOFF

ON OFF

ONOFF

Blow-OffSolenoid

VacuumSolenoid

T2: Blow-Off Delay TimerBT: Blow-Off Timer

Mode: OP3 "Signal Controlled Vacuum"

PSI

inHg

(P-v) Peak ValueON (H-v) Vacuum

OFF (h-v)

OFF (h-d)

ON (H-d) Blow-Off

T2BT

H-V / H-d: Switchpointsh-v / h-d: SwitchpointsP-V: Peak Value

ut dt

Sensor Output 1

Timer Mode OP3“Signal Controlled Vacuum”The vacuum timer option (t1) is omitted and the PLC controlsthe input signal time for the vacuum operation. The delaytimer between vacuum / blow-off (t2) and the blow-off (bt)timers are still available. After selecting OP3, set bt and t2values by using arrow “UP” and “DOWN” keys. To bypassany of these timing function operations, simply enter 0.00seconds and the sensor will automatically proceed to thenext function.

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMVS-201 Genius

Operating ModesDescription of operation modes and terms on page 20.

Screen Saver FunctionThis reduces current consumption by 20mA and will activateafter 10 seconds.

Peak Value Level (P-v)The sensor records this value for preventative maintenaceissues. If this value is not reached the sensor will display anerror message (ALP) indicating leaks or wear in the system.

Vacuum Level Response Time (ut)The sensor records the time (sec) to reach Output 1 and willdisplay an error message (ALu) indicating Output 1 has notbeen reached within the acceptable time (sec) set by theuser.

Blow-off Time (dt)The sensor records the time (sec) to complete blow-offcycle and will display an error message (ALd) indicating(dt) has not reacting within the acceptable time (sec) set bythe user.

Operating Modes Additional Sensor Features(Available in All Operating Modes)

Note:Output Circuit provides vacuum and blow-off confirmation signal(Input Signal to PLC).Input Circuit controls vacuum solenoid valve(Output Signal from PLC).

pneu

air

e

Page 20: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic20 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMVS-201 Genius

2 1

Operating Mode 11

2 1

Press 1xOperating Mode 2 Operating Mode 3

Switch Output4

2 1 OutmodeOpen orClosed

Screen SaverPeak Vacuum LevelVacuum Level Response TimeBlow-off Time

2 32 1

Operation 1: Air Conservation / Timer

Operation 3: Signal Controlled Vacuum

Operation 2: Vacuum Timer Option

Blow-Off Timer

Controlled Vacuum Signal with Timer

Blow-Off Activation Timer

Switch Output Value (H-v)

Switch Output Hysteresis Value (h-v)

Blow-off Output Value (H-d)

Blow-off Output Hysteresis Value (h-d)

Output 1

Vacuum Valve (Leave NO)

Blow-off Release Valve (Leave NO)

Screen Saver Function

Peak Vacuum Level Recorder (P-v)

Vacuum Response Time Recorder

Blow-Off Time Recorder

Normally Open

Normally Closed

Error Message - Peak Vacuum Level

Error Message - Vacuum Response Time

Error Message - Blow-off Time

Low or High Signal to Vacuum Valve

Programming Symbols Legend

pneu

air

e

Page 21: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

21 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Accessories

M8 Cables for Sensor

Catalog 0802-2/USA

AccessoriesPressure SensorsMVS-201 Genius

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

CVK-D201G

6"(152 mm)

9"(229 mm)

VacuumValve

VacuumBlow-off Valve

MC2-C201G

VacuumValve

VacuumBlow-off Valve

Black

Blue

MVS-201 Cables(Connects Sensor to Vacuum & Blow-off Release Pilot Valves)

CVR2-C201G

VacuumValve

VacuumBlow-off Valve

For CVR2

For CVK

For MC2pneu

air

e

Page 22: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic22 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-3 Versatile Panel Mount

Catalog 0802-2/USA

Features

Features• Pressure Ranges:

Positive Pressure ................ 0 to 145 PSIVacuum Pressure ...............0 to -30 inHgLow Pressure ..................... 0 to 14.7 PSICompound .................... -14.7 to 72.5 PSI

• Sensor Outputs:2 NPN or PNP Open CollectorTransistor Output, 30VDC, 125mA

Optional Analog, 1 to 5 VDC

• Switch Point and High-low Programming

• 4 Selectable Units of Measure(mmHg, -bar, -kPa, inHg)(kgf/cm2, PSI, bar, kPa)

• Automatic Teach Mode

• Auto Surveillance for Peak PressureMonitoring

• Output Response Time Less Than 2.0Milliseconds

• CE Marked

• Air and Non-Corrosive Gases

• Error Message

MPS-3

Output Modes

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

The MPS-3 Series Sensor has twoindependent NPN or PNP open collectoroutput signals. An analog output is optional.The Switch Output Mode has a switch pointprogrammed by the user at a specificpressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the Switch Point (H).The Window Comparator Mode provides twoSwitchpoint Settings (A) and (b) that controlthe output signals (NPN / PNP) between twopressures. This is referred to as the “High /Low” setting.

The optional Analog Output Signal iscalibrated to the pressure scale of the sensor.

Switch Output

Window Comparator Output

Model Number Output Pressure Range

MPS-P3N-NG NPN 0 to 145 PSI

MPS-P3N-PG PNP 0 to 145 PSI

MPS-V3N-NG NPN 0 to -30 inHg

MPS-V3N-PG PNP 0 to -30 inHg

MPS-P3N-NC NPN 0 to 145 PSI

MPS-P3N-PC PNP 0 to 145 PSI

MPS-V3N-NC NPN 0 to -30 inHg

MPS-V3N-PC PNP 0 to -30 inHg

pneu

air

e

Page 23: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

23 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Ordering Information, SpecificationsPressure SensorsMPS-3 Versatile Panel Mount

Pressure Range Vacuum (V) Positive (P) Compound (R) Low (L)

bar: 0.001 bar: 0.01 bar: 0.01 bar: 0.001Units of Measure kPa: 0.1 MPa: 0.001 kPa: 1 kPa: 0.1

Display Resolution mmHg: 1 kgf/cm2: 0.01 kgf/cm2: 0.01 kgf/cm2: 0.001inHg: 0.1 PSI: 1 PSI: 0.1 PSI: 0.1

Media Air and Non-Corrosive Gases

Pressure Port N: 1/8" NPSF, R: 1/8" Female BSPT, G: 1/8" BSPP Female

Proof Pressure V: 145 PSI, P: 290 PSI, R: 217 PSI, L: 145 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector, G: Grommet Open Lead, XS2H: M12, 4-Pin

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LED

Display Refresh .1 to 3.0 sec. (Factory set at 0.1)

Output Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30VDC, 125mA

Switch Outputs 2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator

Linear Output Optional Analog Output 1 to 5VDC

Output Modes Hysteresis or Window Comparator

Output Response Time < 2ms with Programmable Increment 32, 128, 1024ms (XS2H2-32, 256, 512ms)

Repeatability ± 0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP65 or IP 40, CE Marked, EMC-EN55011 Class B, EN 50082-2

Current Consumption < 55mA

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Housing: Polycarbonate, Pressure Port: Zinc Die-cast

Mass 1.58 oz. (45g)

Specifications

MPS - V 3 N - P C –

Pressure RangeV 0 to -30 inHgL 0 to 14.7 PSIP 0 to 145 PSIR -14.7 PSI to

72 PSI

Port SizeN 1/8" NPSFR 1/8" BSPTG 1/8" BSPP

CircuitN NPN Sinking OutputP PNP Sourcing Output

Electrical ConnectorC 4-Pin, M8G Grommet (2m)XS2H 4-Pin M12

MPS-V3N-PC MPS-V3N-PG MPS-P3N-PXS2H

Analog OutputBlank WithoutA 1 to 5VDC

Mounting Bracket MPS-ACCK1 Included with Sensors.

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 24: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic24 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-3 Versatile Panel Mount

Catalog 0802-2/USA

Technical Information

Internal Circuit for Open Collector and Analog Output Wiring

Mai

n C

ircu

it

DC1 to 5V

Max. 125mA

Max. 125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(White) Analog

Option

Load

Load

D1

ZD1

ZD21K

ZD3

Tr1

Tr2+

Mai

n C

ircu

it

DC1 to 5V

Max.125mA

Max.125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(White) Analog

Option

Load

Load

D1

ZD1ZD2

1K ZD3

Tr1

Tr2+

NPN PNP

Display Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

Er2 Auto Teach Mode Error Restart Function

CE1 Over current of Output 1 Load current exceeds

CE2 Over current of Output 2 maximum 125mA.

FFF Applied pressure exceeds Apply pressures within–FF pressure range the rating of the sensor

BarbCouplingO-Ring

Ambient AirInlet Port

–INCLUDED–

Pipe Plug

CautionsThe MPS-3 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install as shown using the metal mounting bracket.• To achieve IP65 rating, connect the o-ring and barb as

shown to a normal environment with a 2mm I. D. tube.

Error Messages

Sensor Pin Out with Analog OutputSensor Pin Out2

1

4

3

Lead Wiring

Pin #1 Brown: 24VDC2 White: NPN / PNP Open Collector Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Pin #1 Brown: 24VDC2 White: Analog 1 to 5VDC 3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

2

1

4

3

Brown V+

White NPN / PNP Output

Blue 0V

Black NPN / PNP Output

Brown V+

White Analog 1 to 5 VDC

Blue 0V

Black NPN / PNP Output

Lead Wiring

pneu

air

e

Page 25: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

25 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Dimensions

.177 Dia(4,5)

.79(20)

.98(25)

.23(5,5)

1.37(35)

1.69(43)

.28(7)

.79(20)

1.06(27)

.87(22)

.23(5,5)

.24(6)

.177 Dia(4,5)

.79(20)

.55(14)

1.18 (30)

.79(20)

1.10(28)

.55(14)

.52(13)

.52(13)

MPS-ACCK1MountingBrackets(Included)

1.18(30)

1.06(27)

.79(20).51(13)

.18(4,5)

.33(8,5)

1.18(30)

.79(20)

.16(4)

.46(12,2)

M8

.26(6,7)

M3VentingPort

Grommet Lead 4-Pin Connector

1.18(30)

1.18(30)

.16(4)

3.38(85,6)

M12 4-Pin Connector

212121

N 1/8 NPTR 1/8 BSPTG 1/8 BSPP

Pressure SensorsMPS-3 Versatile Panel Mount

Catalog 0802-2/USA

Dimensions

N, R, G1/8" Female

pneu

air

e

Page 26: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic26 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMPS-3 Versatile Panel Mount

1 2 3

4 5 6

7 8 9

1011 12

Output Set Openor Closed SelectingUnits of MeasureEasy Mode Activation

Output Mode 1Hysteresis orWindowComparator

Output Mode 2Hysteresis orWindowComparator

Output 1Switch PointSetting

Output 2Switch PointSetting

Automatic Teach Mode& Auto Surveillance

Display RefreshSettings / OutputResponse TimeInterval

Lock Unlock

Special DisplayFeatures

ZeroReset

Display Peak ValueBottom Value orTheir Difference

VacuumCycle

ReleaseCycle

Press 6x

Press for 3 Seconds

Press 1x

HoldPress 1x

Press 7x Press 8x

Press 3x

Press 2x

Press 5x

Press 4x

HoldPress 1x

HoldPress 1x

Window Comparator Mode Window Comparator Mode

HysteresisMode

HysteresisMode

Low Low

High High

PeakValue

BottomValue

Press 1x Press 1x

See page 87 for Symbol Explanation

pneu

air

e

Page 27: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

27 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

AccessoriesPressure SensorsMPS-3 Versatile Panel Mount

Accessories

Cables

MPS-ACCH7Panel MountingBracket

1.57(40)

1.72(43,8)

1.57(40)

1.31(33,4)

1.42(36)

(+0.5, -0.2)

1.42(36)

(+0.5, -0.2)

Knockout21

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

pneu

air

e

Page 28: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic28 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

FeaturesPressure SensorsMPS-3 Stainless Steel

Features• Fluids Non-Corrosive to Stainless Steel

SUS 316L or SUS 630Air FreonsAmmonia Lubricating OilsBrake Fluids NitrogenHelium WaterHydraulic Fluids

• Pressure Ranges:Positive Pressure ............... 0 to 145 PSIVacuum Pressure ............. 0 to -30 inHgCompound ................... -14.7 to 72.5 PSI

• Sensor Outputs:2 NPN or PNP Open CollectorTransistor Outputs, 30VDC, 125mA

Optional Analog Output, 1 to 5 VDC

• Switch Point and High-low Programming

• 4 Selectable Units of Measure(mmHg, -bar, -kPa, inHg)(kgf/cm2, PSI, bar, kPa)

• Automatic Teach Mode

• Auto Surveillance for Peak PressureMonitoring

• Output Response Time Less Than 2.0Milliseconds

• CE Marked

• Error Message

MPS-3Stainless Steel

Output Modes

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

Switch Output

Window Comparator Output

Model Number Output Pressure Range

MPS-P3S5-NC 2 NPN 0 to 145 PSI

MPS-P3S5-PC 2 PNP 0 to 145 PSI

MPS-V3F5-NCANPN &

0 to -30 inHgAnalog

MPS-V3F5-PCAPNP &

0 to -30 inHgAnalog

MPS-P3S5-NCANPN &

0 to 145 PSIAnalog

MPS-P3S5-PCAPNP &

0 to 145 PSIAnalog

The MPS-3 Stainless Steel Series Sensor hastwo independent NPN or PNP open collectoroutput signals. An analog output is optional.The Switch Output Mode has a switch pointprogrammed by the user at a specificpressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the Switch Point (H).The Window Comparator Mode provides twoSwitchpoint Settings (A) and (b) that controlthe output signals (NPN / PNP) between twopressures. This is referred to as the “High /Low” setting.

The optional Analog Output Signal iscalibrated to the pressure scale of the sensor.

pneu

air

e

Page 29: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

29 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Ordering Information, SpecificationsPressure SensorsMPS-3 Stainless Steel

Pressure Range Vacuum (V3F) Positive (P3S) Compound (R3F)

bar: 0.001 bar: 0.01 bar: 0.01Units of Measure kPa: 0.1 MPa: 0.001 kPa: 1

Display Resolution mmHg: 1 kgf/cm2: 0.01 kgf/cm2: 0.01inHg: 0.1 PSI: 1 PSI: 0.1

Media Fluids, Non-Corrosive to 316L or 630 SUS

Pressure Port 5: M5F, VC: Semi-Conductor Type Connector

Proof Pressure V3F: 145 PSI, P35: 290 PSI, R3F: 217.5 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector, G: Grommet Open Lead

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LED

Display Refresh .1 to 3.0 sec. (Factory set at 0.1)

Output Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor; 30VDC, 125mA

Switch Outputs 2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator

Linear Output Optional Analog Output 1 to 5VDC

Output Modes Hysteresis or Window Comparator

Output Response Time < 2ms with Programmable Increment 32, 128, 1024ms

Repeatability ± 0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP 65 or IP 40, CE Marked, EMC-EN55011 Class B, EN 50082-2

Current Consumption < 55mA

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Housing: Polycarbonate, Wetted Parts: P: 316L or V,R: 630 SUS (Diaphragm)

Mass 4.4 oz. (110g)

Specifications

MPS-P3S5-NGA MPS-P3SVC-NGAMPS-P3S5-PC

MPS - P3S 5 - P C –

Pressure RangeV3F 0 to -30 inHgP3S 0 to 145 PSIR3F -14.7 PSI to

72 PSI

Port Size5 M5F 316SSVC VC Type 316SS

CircuitN NPN Sinking

OutputP PNP Sourcing

Output

Electrical ConnectorC 4-Pin, M8G Grommet (2m)

Analog OutputBlank WithoutA 1 to 5VDC

Mounting Bracket MPS-ACCK1 Included with Sensors.

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 30: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic30 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-3 Stainless Steel

Catalog 0802-2/USA

Technical Information

CautionsThe MPS-3 Stainless Steel Pressure Sensor is designed tomonitor pressure and is not a safety measure to preventaccidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! • Depending on the system fluid and design, it may benecessary to protect the diaphragm against pressurespikes by installing a flow restriction upstream from thesensor.

Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install using the metal mounting base.• To achieve IP65 rating, connect the o-ring and barb to a

normal environment with a 2mm I. D. tube.

Error MessagesDisplay Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

Er2 Auto Teach Mode Error Restart Function

CE1 Over current of Output 1 Load current exceeds

CE2 Over current of Output 2 maximum 125mA.

FFF Applied pressure exceeds Apply pressures within–FF pressure range the rating of the sensor

Internal Circuit for Open Collector and Analog Output Wiring

Mai

n C

ircu

it

DC1 to 5V

Max. 125mA

Max. 125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(White) Analog

Option

Load

Load

D1

ZD1

ZD21K

ZD3

Tr1

Tr2+

Mai

n C

ircu

it

DC1 to 5V

Max.125mA

Max.125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(White) Analog

Option

Load

Load

D1

ZD1ZD2

1K ZD3

Tr1

Tr2+

NPN PNP

2

1

4

3

Sensor Pin Out Sensor Pin-Out with Analog OutputPin #

1 Brown: 24VDC2 White: NPN / PNP Open Collector Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Pin #1 Brown: 24VDC2 White: Analog 1 to 5VDC Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Brown V+

White NPN / PNP Output

Blue 0V

Black NPN / PNP Output

Lead Wiring

2

1

4

3

Brown V+

White Analog 1 to 5 VDC

Blue 0V

Black NPN / PNP Output

Lead Wiring

pneu

air

e

Page 31: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

31 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

1.75(44,5) .39

(10)

.26(6,7)

M34 Places

.79(20)

.79(20)

M5

1.18(30)

1.18(30)

.16(4)

.46(12,2)

M8

4-Pin Connector Grommet Lead

M3VentingPort

.26(6,7)

M34 Places

.79(20)

.79(20)

1.75(44,5)

3.50(88,9)

.39(10)

Catalog 0802-2/USA

DimensionsPressure SensorsMPS-3 Stainless Steel

DimensionsM5 Back & Bottom Ports

VC ConnectionGrommet orM8, 4-Pin

.177 Dia(4,5)

.79(20)

.98(25)

.23(5,5)

1.37(35)

1.69(43)

.28(7)

.79(20)

1.06(27)

.87(22)

.23(5,5)

.24(6)

.177 Dia(4,5)

.79(20)

.55(14)

1.18 (30)

.79(20)

1.10(28)

.55(14)

.52(13)

.52(13)

MPS-ACCK1MountingBrackets(Included)

pneu

air

e

Page 32: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic32 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMPS-3 Stainless Steel

1 2 3

4 5 6

7 8 9

1011 12

Output Set Openor Closed SelectingUnits of MeasureEasy Mode Activation

Output Mode 1Hysteresis orWindowComparator

Output Mode 2Hysteresis orWindowComparator

Output 1Switch PointSetting

Output 2Switch PointSetting

Automatic Teach Mode& Auto Surveillance

Display RefreshSettings / OutputResponse TimeInterval

Lock Unlock

Special DisplayFeatures

ZeroReset

Display Peak ValueBottom Value orTheir Difference

VacuumCycle

ReleaseCycle

Press 6x

Press for 3 Seconds

Press 1x

HoldPress 1x

Press 7x Press 8x

Press 3x

Press 2x

Press 5x

Press 4x

HoldPress 1x

HoldPress 1x

Window Comparator Mode Window Comparator Mode

HysteresisMode

HysteresisMode

Low Low

High High

PeakValue

BottomValue

Press 1x Press 1x

See page 87 for Symbol Explanation

pneu

air

e

Page 33: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

33 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

AccessoriesPressure SensorsMPS-3 Stainless Steel

Accessories

Cables

MPS-ACCH1Panel MountingBracket

1.57(40)

1.72(43,8)

1.57(40)

1.31(33,4)

1.42(36)

(+0.5, -0.2)

1.42(36)

(+0.5, -0.2)

Knockout21

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

pneu

air

e

Page 34: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic34 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

FeaturesPressure SensorsMPS-31 2-Color Panel Mount

Features• Pressure Ranges:

Positive Pressure ................ 0 to 145 PSIVacuum Pressure ...............0 to -30 inHgCompound .................... -14.7 to 72.5 PSI

• Sensor Output:1 NPN or PNP Open CollectorTransistor Output, 30VDC, 125mA

Optional Analog Output, 4 to 20mA

• Switch Point and High-low Programming

• 4 Selectable Units of Measure(mmHg, -bar, -kPa, inHg)(kgf/cm2, PSI, bar, kPa)

• Programmable Display Colors

• Output Response Time Less Than 2.0Milliseconds

• CE Marked

• Air and Non-Corrosive Gases

• Error Message

Output Modes

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

The MPS-31 Series Sensor has oneindependent NPN or PNP open collectoroutput signal. The Switch Output Mode has aswitch point programmed by the user at aspecific pressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the Switch Point (H).The Window Comparator Mode provides twoSwitchpoint Settings (A) and (b) that controlthe output signals (NPN / PNP) between twopressures. This is referred to as the “High /Low” setting.

Switch Output

Window Comparator Output

Model Number Output Pressure Range

MPS-P31N-NG NPN 0 to 145 PSI

MPS-P31N-PG PNP 0 to 145 PSI

MPS-V31N-NG NPN 0 to -30 inHg

MPS-V31N-PG PNP 0 to -30 inHg

MPS-P31N-IC 4 to 20mA 0 to 145 PSI

MPS-P31N-NC NPN 0 to 145 PSI

MPS-P31N-PC PNP 0 to 145 PSI

MPS-V31N-NC NPN 0 to -30 inHg

MPS-V31N-PC PNP 0 to -30 inHg

MPS-31Red Green Displaypneu

air

e

Page 35: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

35 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Ordering Information, SpecificationsPressure SensorsMPS-31 2-Color Panel Mount

Pressure Range Vacuum (V) Positive (P) Compound (R)

bar: 0.001 bar: 0.01 bar: 0.01Units of Measure kPa: 0.1 MPa: 0.001 kPa: 1

Display Resolution mmHg: 1 kgf/cm2: 0.01 kgf/cm2: 0.01inHg: 0.1 PSI: 1 PSI: 0.1

Media Air and Non-Corrosive GasesPressure Port N: 1/8" NPSF, R: 1/8" BSPT, G: 1/8" BSPP

Proof Pressure V: 145 PSI, P: 217.5 PSI, R: 145 PSIOperating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector, G: Grommet Open LeadPower Supply 10.8 to 26.4VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LEDDisplay Refresh .1 to 3.0 sec. (Factory set at 0.1)

Output Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30VDC, 125mASwitch Output Output Signal, NPN or PNP, Normally Open or Closed, LED IndicatorOutput Modes Hysteresis or Window Comparator

Output Response Time < 2ms, 32, 256, 512ms Programmable (Factory set 2ms)Repeatability ± 0.2% F.S.

Output Current: 4 to 20mAAnalog Current Linearity: ±0.5% F.S. or lessOutput Output Maximum Load Impedance: 300Ω with power supply voltage of 12V; 600Ω with power

supply voltage of 12V; Minimum Load Impedance: 50ΩThermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP40, CE Marked, EMC-EN55011 Class B, EN 50082-2Current Consumption < 70mAVibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZMaterial Housing: Polycarbonate, Pressure Port: Zinc Die-cast

Mass 1.7 oz. (45g)

Specifications

MPS - V 31 N - P C –

Pressure RangeV 0 to -30 inHgP 0 to 145 PSIR -14.7 PSI to

72 PSI

Output CircuitN NPN Sinking OutputP PNP Sourcing Output

Electrical ConnectorC 4-Pin, M8G Grommet (2m)

MPS-V31N-PG

Port SizeN 1/8" NPSFR 1/8" BSPTG 1/8" BSPP

MPS-V31N-PC

Mounting Bracket MPS-ACCK1 Included with Sensors.

Model Number IndexBold Items Are Stocked

Analog OutputBlank WithoutI 4 to 20mA

Current

pneu

air

e

Page 36: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic36 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-31 2-Color Panel Mount

Catalog 0802-2/USA

Technical Information

CautionsThe MPS-31 Pressure Sensor is designed to monitorpressure and is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install as shown using the metal mounting bracket.

Error MessagesDisplay Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

CE1 Over current of Output 1 Load current exceeds

FFF Applied pressure exceeds Apply pressures within–FF pressure range the rating of the sensor

Internal Circuit for Open Collector and Analog Output Wiring

Mai

n C

ircu

it

Max. 125mA

Max. 125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(Black) Out 1

(White) 4 AnalogLoad

D1

ZD1

ZD21K

ZD3

Tr1

Tr2+

Mai

n C

ircu

itMax.

125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(Black) Out 1

(White) 4 Analog

Load

D1

ZD1ZD2

1K ZD3

Tr1

Tr2+

NPN PNP

Sensor Pin Out with Analog OutputSensor Pin Out2

1

4

3

Lead Wiring

Pin #1 Brown: 24VDC2 White: Not Used3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Pin #1 Brown: 24VDC2 White: 4 to 20mA3 Blue: 0VDC4 Black: NPN / PNP Open

2

1

4

3

Brown V+

Black NPN / PNP Output

Blue 0V

Brown V+

White 4 to 20 mA

Blue 0V

Black NPN / PNP Output

Lead Wiring

(Revised 10/13/04)

pneu

air

e

Page 37: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

37 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

DimensionsPressure SensorsMPS-31 2-Color Panel Mount

DimensionsN, R, G1/8" Female

1.18(30)

1.06 (27)

.79(20).51(13)

.18 (4,5)

.33(8,5)

1.18(30)

.79(20)

.16 (4)

.46 (12,2)

M8

.26 (6,7)

M3VentingPort

Grommet Lead 4-Pin Connector

N 1/8 NPTR 1/8 BSPTG 1/8 BSPP

.177 Dia(4,5)

.79(20)

.98(25)

.23(5,5)

1.37(35)

1.69(43)

.28(7)

.79(20)

1.06(27)

.87(22)

.23(5,5)

.24(6)

.177 Dia(4,5)

.79(20)

.55(14)

1.18 (30)

.79(20)

1.10(28)

.55(14)

.52(13)

.52(13)

MPS-ACCK1MountingBrackets(Included)

pneu

air

e

Page 38: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic38 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesPressure SensorsMPS-31 2-Color Panel Mount

Output NormallyOpen or Closed

OperatingOutput Mode

DisplayRefresh

Begin Programming

Select Unitsof Measure

Switch OutputSetting andLow Setting

HysteresisSetting andHigh Setting

Hysteresis ModeHysteresis Mode

Window Comparator Mode

Output ResponseSelection

Display Color ChoicesRed and / or Green,Energy Save

Lock Unlock

1

2 3

4

ZeroReset

5

Red

Green

Red

Green

Green

Red

Red

Green

Low High

Press for 3 Seconds

Press 1 x Press 1 x

HoldPress 1 x

HoldPress 1 x

Press for3 Sec.

Or Press 1x to Proceed

Or Press 1x to Proceed Or Press 1x to Proceed Or Press 1x to Return

Or Press 1x to Proceed Or Press 1x to Proceed

Wait 3 Seconds

Wait 3 Seconds

Will Display for 1 Second Will Display for 1 Second

Wait 5 Seconds

Wait 3 Seconds Wait 3 Seconds

Wait 3 Seconds Wait 3 Seconds

OutputOn Off

Window Comparator Mode

Wait 5 Seconds

See page 87 for Symbol Explanation

pneu

air

e

Page 39: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

39 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

AccessoriesPressure SensorsMPS-31 2-Color Panel Mount

Accessories

Cables

MPS-ACCH7Panel MountingBracket

1.57(40)

1.72(43,8)

1.57(40)

1.31(33,4)

1.42(36)

(+0.5, -0.2)

1.42(36)

(+0.5, -0.2)

Knockout

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

pneu

air

e

Page 40: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic40 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Differential Pressure SensorsMPS-4 Sensitive

Catalog 0802-2/USA

Features / Common Part Numbers

Features• Pressure Ranges:

Positive Pressure.................. -8 to 8 inH2OVacuum Pressure .............. 0 to -29.8 inHg

• Sensor Outputs:2 NPN or PNP Open CollectorTransistor Output, 30VDC, 125mA

Optional Analog Output, 1 to 5 VDC

• Switch Point and High-low Programming

• Selectable Units of Measure

• Output Response Time Less Than 2.5Milliseconds

• CE Marked

• Air and Non-Corrosive Gases

• Dual Ports for Reference Pressure

MPS-4

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

The MPS-4 Differential Pressure Sensormonitors pressure in applications where smallchanges in pressure are critical.The MPS-4 has two independent NPN or PNPopen collector output signals. The SwitchOutput Mode has a switch point programmedby the user at a specific pressure. TheHysteresis Range (h) adjustment controls theoutput signal 0 to 100% below the SwitchPoint (H) settings which are programmed onthe sensor by the user.The Window Comparator Mode provides twoSwitchpoint Settings (A) and (b) that controlthe output signals (NPN / PNP) between twopressures. This is referred to as the “High /Low” setting.

The optional Analog Output Signal iscalibrated to the pressure scale of the sensor.

Output Modes Switch Output

Window Comparator Output

Model Number Output Pressure Range

MPS-D4M5-NC NPN -8 to +8 inH2O

MPS-D4M5-PC PNP -8 to +8 inH2O

pneu

air

e

Page 41: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

41 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Differential Pressure SensorsMPS-4 Sensitive

Catalog 0802-2/USA

Ordering Information, Specifications

MPS - D 4 M5 - P C - –

Pressure RangeD -8 inH2O to 8 inH20V 0 to -29.8 inHg

Output CircuitN NPN SinkingP PNP Sourcing

Electrical ConnectorC 4-Pin, M8G Grommet (2m)

Optional OutputBlank WithoutA Analog (1 to 5VDC)

Media Air and Non-Corrosive Gases

Pressure Port M5 Female (2 qty.)

Proof Pressure V: 29 PSI, D: 3.9

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection G: Grommet Lead, C: 4-Pin, M8 Connector

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LED

Resolution & Units of Measure kPa: 0.01, mmH2O: 1, inH2O: 0.1, inHg: 0.1

Display Refresh .1 to 3.0 sec. (Factory set at 0.1)

Output Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30VDC, 125mA

Switch Outputs 2 Output Signals, Normally Open or Closed, LED Indicator

Linear Output Optional Analog Output 1-5VDC, ± 0.2% Linear Accuracy 0.5% F.S.

Output Modes Hysteresis or Window Comparator

Output Response Time D: < 2.5ms

Repeatability D: < ± 0.5% F.S.

Thermal Error Max. ±3% F.S. in Temperature Range: 32 to 122°F (0 to 50°C)

General Protection IP40, CE Marked, EMC Rating: EN55011 Class B, EN50082-2

Current Consumption < 45mA

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Housing: Polycarbonate, Pressure Port: Anodized Aluminum

Mass 1.6 oz. (45g)

Specifications

PortM5 M5 Port

MPS-D4M5-PC

Mounting Bracket MPS-ACCK1 Included with Sensors.

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 42: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic42 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Differential Pressure SensorsMPS-4 Sensitive

Catalog 0802-2/USA

Technical Information

CautionsThe MPS-4 Differential Pressure Sensor is designed to monitorpressure and is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.

• Install using the metal mounting bracket.

Error MessagesDisplay Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

CE1 Over current of Output 1 Load current exceeds

CE2 Over current of Output 2 maximum 125mA.

FFF Applied pressure exceeds Apply pressures with–FF pressure range the rating of the sensor

Internal Circuit for Open Collector and Analog Output Wiring

Mai

n C

ircu

it

DC1 to 5V

Max. 125mA

Max. 125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(White) Analog

Option

Load

Load

D1

ZD1

ZD21K

ZD3

Tr1

Tr2+

Mai

n C

ircu

it

DC1 to 5V

Max.125mA

Max.125mA

DC10.8V 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(White) Analog

Option

Load

Load

D1

ZD1ZD2

1K ZD3

Tr1

Tr2+

NPN PNP

2

1

4

3

Sensor Pin Out Sensor Pin-Out with Analog OutputPin #

1 Brown: 24VDC2 White: NPN / PNP Open Collector Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Pin #1 Brown: 24VDC2 White: Analog 1 to 5VDC Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

Brown V+

White NPN / PNP Output

Blue 0V

Black NPN / PNP Output

Lead Wiring

2

1

4

3

Brown V+

White Analog 1 to 5 VDC

Blue 0V

Black NPN / PNP Output

Lead Wiring

pneu

air

e

Page 43: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

43 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Differential Pressure SensorsMPS-4 Sensitive

Catalog 0802-2/USA

Dimensions

Dimensions

M5 Female

.177 Dia(4,5)

.79(20)

.98(25)

.23(5,5)

1.37(35)

1.69(43)

.28(7)

.79(20)

1.06(27)

.87(22)

.23(5,5)

.24(6)

.177 Dia(4,5)

.79(20)

.55(14)

1.18 (30)

.79(20)

1.10(28)

.55(14)

.52(13)

.52(13)

MPS-ACCK1MountingBrackets(Included)

1.18(30)

1.18(30)

M34 Places

.79(20)

.33(8,5)

.79(20)

.47(12)

B M5 - 6,5

A M5 - 6,5

.96(24,5)

.39(10)

.39(10)

1.75(44,5)

1 2

1.18(30)

1.18(30)

.16(4)

.46(12,2)

M8

4-Pin Connector

21

Grommet Lead

pneu

air

e

Page 44: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic44 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Programming FeaturesDifferential Pressure SensorsMPS-4 Sensitive

Port ReferenceSelection

1 2 3

4 5 6

7 8

9

B Port

A Port

Output 1Switch PointSetting

Press 1xOutput 2Switch PointSetting

Press 3x Press 5x

Output Set Openor Closed Selecting

Units of Measure

Display RefreshSettings / OutputResponse TimeInterval

Display Peak ValueBottom Value orTheir Difference

Press 6x Press 7x

Output Mode 1Hysteresis orWindowComparator

Output Mode 2Hysteresis orWindowComparator

Press 2x Press 4x

11

Lock Unlock

ZeroReset

10

PeakValue

BottomValue

Hold for 3 Seconds

HoldPress 1x

HoldPress 1x

Press 1x Press 1x

HoldPress 1x

Window ComparatorMode

Window ComparatorMode

HysteresisMode

HysteresisMode

Low Low

High High

See page 87 for Symbol Explanation

pneu

air

e

Page 45: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

45 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Differential Pressure SensorsMPS-4 Sensitive

Catalog 0802-2/USA

Accessories

Accessories

Cables

MPS-ACCH1Panel MountingBracket

1.57(40)

1.72(43,8)

1.57(40)

1.31(33,4)

1.42(36)

(+0.5, -0.2)

1.42(36)

(+0.5, -0.2)

Knockout21

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

pneu

air

e

Page 46: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic46 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure TransducerMPS-5 Stainless Steel

Catalog 0802-2/USA

Features / Common Part Numbers

Features• Pressure Ranges:

Positive Pressure ................ 0 to 145 PSIVacuum Pressure ...............0 to -30 inHg

• Sensor Output:1 to 5 VDC

• 316L SUS Diaphragm (Positive)

• 630 SUS Diaphragm (Vacuum)

• Compatible with MPS-7 Display forRemote Sensing

• CE Marked

MPS-5Stainless

5

00 Max. Rating

1

Pressure

Ou

tpu

t (V

olt

s)

Analog Output

Model Number Output Pressure Range

MPS-P5N-AC Analog 0 to 145 PSI

MPS-P5N-AG Analog 0 to 145 PSI

MPS-P5N-AGE Analog 0 to 145 PSI

MPS-V5FN-AC Analog 0 to -30 inHg

MPS-V5FN-AG Analog 0 to -30 inHg

MPS-V5FN-AGE Analog 0 to -30 inHg

The MPS-5 Series Transducer is constructedof 316L or 630 SUS with Analog outputcapabilities. The sensor can be used as astand alone unit or in combination with theMPS-7 Sensor Display. The analog output is1 to 5VDC (± 0.04) with accuracy linear0.5% F.S.

pneu

air

e

Page 47: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

47 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure TransducerMPS-5 Stainless Steel

Catalog 0802-2/USA

Ordering Information, Specifications

Media Liquids and Gases Non-Corrosive to 316SS

Pressure Port R: 1/4" Male BSPT, N: 1/4" Male NPT with M5 Female

Proof Pressure V: 145 PSI, P: 290 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector, G: Grommet Open Lead, GE: Clip Type for use with MPS-7

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Linear Output Analog Output 1 to 5VDC

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP65, CE Marked, EMC Rating: EN55011 Class B, EN50082-2

Current Consumption < 20mA

Spike Protection 400 VP, 1 µs

Dielectric Strength 1000VAC, 1min.

Insulation Resistance > 100M ohms at 500VDC

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Housing: 303SUS, Wetted Parts: P5: 316L SUS, V5F: 630 SUS (Diaphragm)

Mass 3.88 oz. (110g)

Specifications

MPS - V5F N - A G

Pressure RangeV5F 0 to -30 inHgP5 0 to 145 PSI

Output CircuitA Analog 1 to 5VDC

Electrical ConnectorC 4-Pin, M8G Grommet (2m)GE 2m Grommet Clip Conn.*

*Use with MPS-7 Series Display

Port SizeR 1/4" BSPT Male, M5FN 1/4" NPT Male, M5F

MPS-V5FN-AGMPS-V5FN-AC MPS-V5FN-AGE

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 48: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic48 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

Technical InformationPressure TransducerMPS-5 Stainless Steel

Pin #1 Brown: 24VDC2 Black: Analog 1-5VDC3 Blue: 0VDC4 Not Used

Analog

Internal Circuit

CautionsThe MPS-5 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

!• Depending on the system fluid and design, it may be

necessary to protect the diaphragm against pressure spikesby installing a flow restriction upstream from the sensor.

Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install using the metal mounting base.• To achieve IP65 rating, connect the o-ring and barb to a

normal environment with a 2mm I. D. tube.

2

1

4

3

Mai

n C

ircui

t

(Blue) OV

(Brown) +V

+

-DC10.8V to 30V(Black) Analog 1 to 5V Output

Sensor Pin Out

Brown V+

White Output 1

Blue 0V

Black Not Used

Lead Wiring

BarbCouplingO-Ring

Ambient AirInlet Port

–INCLUDED–pneu

air

e

Page 49: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

49 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure TransducerMPS-5 Stainless Steel

Dimensions

Catalog 0802-2/USA

Dimensions

6.56 ft(2m)

1.59(40,5)

.59(15)

M5 x 1,0

1.06(27)

1.06 (27)Dia.

.20(5,2)

1/4" NPT (BSPT)

6.56 ft(2m)

1.59(40,5)

.59(15)

M5 x 1,0

1.06(27)

1.06 (27)Dia.

.20(5,2)

1/4" NPT (BSPT)

1.59(40,5)

.59(15)

M5 x 1,0

1.06(27)

1.06 (27)Dia.

1/4" NPT (BSPT)

.46 (12,2)

M8

Housing(AMP) 171822-5

Connector(AMP) 170204-15

Shield

N, R1/4" Male Grommet

N, R1/4" Male GrommetClip Connector

N, R1/4" Male4-Pin, M8 Connector

pneu

air

e

Page 50: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic50 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Accessories

Cables

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-2E, M8 Female

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.69(17)

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

6.56 ft(2m)

.38(9,7) Dia

.196 (5) Dia

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Housing(AMP) 171822-5

Connector(AMP) 170204-15

Shield

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

Catalog 0802-2/USA

AccessoriesPressure TransducerMPS-5 Stainless Steel

pneu

air

e

Page 51: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

51 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

NotesPressure TransducerMPS-5 Stainless Steel

pneu

air

e

Page 52: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic52 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-6 Compact

Catalog 0802-2/USA

Features

Features• Pressure Ranges:

Positive Pressure ................0 to 145 PSIVacuum Pressure .............. 0 to -30 inHg

• Sensor Outputs:1 Open and 1 Closed NPN or PNP OpenCollector Transistor Output, 30VDC,125mA

1 Analog Output, 1 to 5 VDC

• Switch Point 2/3 Trimmer

• Fixed Hysteresis 2%

• Output Response Time Less Than 1Millisecond

• Analog Output Type Compatible withMPS-7 Display

• CE Marked

• Air and Non-Corrosive Gases

MPS-6

Output ModesThe MPS-6 Series Sensor is compact andlightweight with NPN or PNP open connectorswitch output or analog output capabilities.The sensor can be used as a stand alone unitor in combination with the MPS-7 seriesdisplay. The MPS-6 Switch Output unitprovides one open and closed output for thesame switch point. The MPS-6 Analog Outputunit provides analog output 1 to 5VDC.Analog output is required for use with theMPS-7 display.

5

00 Max. Rating

1

Pressure

Ou

tpu

t (V

olt

s)

Fixed2% off off

0

-30 in Hg

on on

S

Switch Output

Analog Output

Model Number Output Pressure Range

MPS-P6N-NC NPN 0 to 145 PSI

MPS-P6N-PC PNP 0 to 145 PSI

MPS-P6N-AG Analog 0 to 145 PSI

MPS-P6N-AGE Analog 0 to 145 PSI

MPS-V6N-NC NPN 0 to -30 inHg

MPS-V6N-PC PNP 0 to -30 inHg

MPS-V6N-AG Analog 0 to -30 inHg

MPS-V6N-AGE Analog 0 to -30 inHg

pneu

air

e

Page 53: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

53 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

MPS - V 6 N - P C

Pressure RangeV 0 to -30 inHgP 0 to 145 PSIG

Port SizeN 1/8" NPT &

M5 FemaleR 1/8" BSPT &

M5 FemaleG 1/8" BSPP &

M5 FemaleT 6mm Tube StudC Ejector

Electrical ConnectorC 4-Pin, M8G Grommet (2m)GE 2m Grommet Clip Conn.*

* Use with MPS-7 Series Display,Analog Output Only.

Output CircuitN NPN OutputP PNPOutputA Analog (1 to 5VDC)

Pressure SensorsMPS-6 Compact

Catalog 0802-2/USA

Ordering Information, Specifications

Media Air and Non-Corrosives Gases

Pressure Port N: 1/8" NPT Male, R: 1/8" BSPT Male, G: 1/8" BSPP Male, T: 6mm Tube Stud

Proof Pressure V: 72.5 PSI, P: 217.5 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection C: 4-Pin, M8 Connector G: Grommet Lead GE: Clip Type for use with MPS-7 Display

Power Supply 10.8 to 30 VDC, Ripple Vp-p 10% max., Reverse Voltage Protection

Switch Output 1 Output Signal Open and Closed, NPN or PNP, 30VDC, 125mA

Linear Output Analog Output 1 to 5 VDC

Switch Point Setting 2/3 Turn Trimmer

Hysteresis Setting < 2% of F.S.

Output Response Time <1ms

Repeatability <0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP40, CE Marked, EN55011 Class B, EN50082-2

Current Consumption < 20mA

Spike Protection 400 VP, 1 µs, Surge Protection

Dielectric Strength 1000VAC, 1min.

Insulation Resistance > 100M ohm at 500VDC

Vibration Resistance 10 to 55Hz, 0.75mm Amplitude, XYZ, 2 hrs.

Shock Resistance 100 G, XYZ

Material Housing: Polycarbonate, Pressure Port: Zinc Die-cast

Mass T Port: 0.25 oz. (7g), N, R, G Port: 0.88 oz. (25g)

Specifications

MPS-P6N-AC MPS-P6N-AG MPS-V6T-PG MPS-P6N-AGE

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 54: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic54 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-6 Compact

Catalog 0802-2/USA

Technical Information

Mai

n C

ircui

t LED(White) Input for LED lighting (5VDC)

(Blue) OV

(Brown) +V

+

-DC10.8V to 30V

Mai

n C

ircui

t

D1

Tr1

Tr2

ZD1

ZD2 (White) Out 2 (N.C.)

(Blue) OV

(Black) Out 1 (N.O.)

(Brown) +V

+

–DC10.8V to 30V

LOADMax. 125mA

LOADMax. 125mA

Mai

n C

ircui

t

D1

Tr1

Tr2

ZD1

ZD2 (White) Out 2 (N.C.)

(Blue) OV

(Black) Out 1 (N.O.)

(Brown) +V

+

–DC10.8V to 30V

Max. 125mA

LOADMax. 125mA

(Black) Analog 1 5V Output

LOAD

Analog PNP Open Collector

Internal Circuit

! CautionsThe MPS-6 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.

Switch PointTrimmer

– +

Trimmer AdjustmentRotate the potentiometer trimmer to increase or decreasepressure switch point output. Excessive force or exceedingthe limits of the trimmers may cause damage.

NPN Open Collector

Sensor Pin Out with Analog OutputSensor Pin Out2

1

4

3

Pin #1 Brown: 24VDC2 White: LED In 5VDC3 Blue: 0VDC4 Black: Analog 1 to 5VDC

Pin #1 Brown: 24VDC2 White: NPN / PNP Open Collector Output3 Blue: 0VDC4 Black: NPN / PNP Open Collector Output

2

1

4

3

pneu

air

e

Page 55: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

55 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsMPS-6 Compact

Catalog 0802-2/USA

Dimensions

Dimensions

N, R, G1/8" Male,M5 Female,Grommet

T6Tube Stud,Grommet

N, R, GGrommetClip Connector

6.56 ft(2m)

1.04(26,3)

.63(16)

.79(20)

.39(10)

6.56 ft(2m)

.39(10)

M5–6

.63(16)

.79(20)

6mm Tube

1.34(34,1)

.78(19.8)

R1/8, G1/8,or 1/8" NPT Output LED Output

LED

OutputLED

Switch Point Trimmer

1.04(26,3)

.63(16)

.79(20)

M5–6

R1/8, G1/8,or 1/8" NPT

.59(15)

.59(15)

Output LEDSwitch Point Trimmer

Output LEDSwitch Point Trimmer

or

Output LED OutputLED

Switch Point Trimmer

or

6.56 ft(2m)

.51(13)

.63(16)

.79(20)

.39(10)

Output LED OutputLED

Switch Point Trimmer

or

or

OutputLED

OutputLED

or

.59(15)

Output LEDSwitch Point Trimmer

OutputLED

or

1.04(26,3)

.63(16)

.79(20)

M5–6

R1/8, G1/8,or 1/8" NPT

6.56 ft(2m)

.63(16)

.79(20)

6mm Tube

1.34(34,1)

.78(19.8)

AMP 5-Pin Connector171822-5

.14(3,5)

.12(3)

.51(13)

.63(16)

.79(20)

.14(3,5)

.12(3)

.63(16)

.79(20)

6mm Tube

1.34(34,1)

.78(19.8)

.51(13)

.63(16)

.79(20)

.14(3,5)

.12(3)

OutputLED

6.56 ft(2m)

AMP 5-Pin Connector171822-5

OutputLED

6.56 ft(2m)

AMP 5-Pin Connector171822-5

CEjector Mount

CEjector Mount

CEjector Mount

N, R, G1/8" Male,M5 Female,M8, 4-Pin

T6Tube Stud,M8, 4-Pin

T6GrommetClip Connectorpneu

air

e

Page 56: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic56 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Accessories

Cables

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-2E, M8 Female

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.69(17)

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

6.56 ft(2m)

.38(9,7) Dia

.196 (5) Dia

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Housing(AMP) 171822-5

Connector(AMP) 170204-15

Shield

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

Pressure SensorsMPS-6 Compact

Catalog 0802-2/USA

Accessories

pneu

air

e

Page 57: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

57 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

NotesPressure SensorsMPS-6 Compact

pneu

air

e

Page 58: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic58 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Multi-Pressure SensorsMPS-7 Display

Catalog 0802-2/USA

Features

Features• One Display with Output Programming

Capability for MPS-5, 6, or 8 AnalogSensors

• Displays Pressure and Converts AnalogSignal from Remote Sensor to NPN orPNP Open Collector Transistor Output,30VDC, 125mA

• Compatible with 1 to 4 Remote Sensors

• MPS-71 Response Time Less Than2.0 Milliseconds

Automatic Teach Mode andAuto Surveillance for PeakPressure Monitoring

• MPS-74 Response Time Less Than5 Milliseconds

Auto Surveillance forPeak Pressure Monitoring

• CE Marked

MPS-7

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

Output Modes Switch Output

Window Comparator Output

The MPS-7 is a central display and control forremote MPS-5, 6, 8 analog sensors. Eachremote sensor supplies an analog signal to aspecific channel on the MPS-7 which isconverted to an open connector output “NPN /PNP”.

The Switch Output Mode has a switch pointprogrammed by the user at a specifiedpressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the Switch Point (H).

The Window Comparator Mode provides twoSwitchpoint Settings (A) and (b) that controlthe output signals (NPN / PNP) between twopressures. This is referred to as the “High /Low” setting.

Model Number Output

MPS-71E-NC NPN

MPS-71E-PC PNP

MPS-71E-NG NPN

MPS-71E-PG PNP

MPS-74E-NG NPN

MPS-74E-PG PNPMPS-71E-PG Control with Remote MPS-P6N-AGE Shown

pneu

air

e

Page 59: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

59 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

MPS - 7 1 E - N C - –

Number of RemoteSensors

1 1 Sensor4 4 Sensors

CircuitN NPN Output SinkingP PNP Output Sourcing

Electrical ConnectorC* 4-Pin, M8G Grommet (2m)* Available on MPS-71 only.

Multi-Pressure SensorsMPS-7 Display

Catalog 0802-2/USA

Ordering Information, Specifications

Remote Pressure Range Vacuum (V) Positive (P) Compound (R) Low (L)

bar: 0.001 bar: 0.01 bar: 0.01 bar: 0.001Units of Measure kPa: 0.1 MPa: 0.001 kPa: 1 kPa: 0.1

Display Resolution mmHg: 1 kgf/cm2: 0.01 kgf/cm2: 0.01 kgf/cm2: 0.001inHg: 0.1 PSI: 1 PSI: 0.1 PSI: 0.1

Proof Pressure See Remote Sensor Specifications

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection G: Grommet Open Lead, C: M8 Connector

Power Supply 10.8 to 30VDC, Ripple (P-P) 10% Max., Reverse Voltage Protection

Display MPS-71: 3-Digit, 7-Segment LED, MPS-74: 4-Digit, 7-Segment LED

Display Refresh MPS-71: 0.1 to 3.0 sec. (Factory set at 0.1), MPS-74: 0.2 Fixed

Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30VDC, 125mA

74 - 1 Switch Output Output Signals, NPN or PNP, LED Indicator71 - 2 Switch Outputs

Linear Output Mode (71 Series) Optional Output - Analog 1-5VDC, ± 0.2% Linear Accuracy, 0.5% F.S

Response Time MPS-71 <2ms, MPS-74 <5ms

Repeatability ± 0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP40, CE Marked

Current Consumption MPS-71 <45mA, MPS-74 <75mA

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Body: Polycarbonate

Mass MPS-71: .90 oz. (25g), MPS-74: 1.0 oz. (30g)

Specifications

MPS-71E-PC MPS-74E-NG

Mounting Bracket Included with Sensors.

Model Number IndexBold Items Are Stocked

Input / Output OptionsBlank WithoutD* Remote Zero ResetA* Analog Output* Available on MPS-71 with Grommet

Electrical Connector Only.

(Revised 10/13/04)

pneu

air

e

Page 60: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic60 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Multi-Pressure SensorsMPS-7 Display

Catalog 0802-2/USA

Technical Information

CautionsThe MPS-7 Central Display is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the MPS-7

Series and set the ripple to Vp-p10% or less. Avoidexcessive voltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

! Installation• Avoid short-circuiting the MPS-7 Series. Connect the brown

lead to V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install using Panel Mount Bracket or Back Mount Brackets.

Display Description Solutions

Err Zero Reset Error Reset Zero

PErr Peak Value Error Check Vacuum SourceReset: Press Mode Key

Er1 System Error (Internal) Contact Factory

CE1 Over current of Output 1

CE2 Over current of Output 2 Load current exceeds

CE3 Over current of Output 3 (MPS-74) maximum 125mA.

CE4 Over current of Output 4 (MPS-74)

FFF Applied pressure exceeds Apply pressures within–FF pressure range the rating of the

sensor

Error Messages

Mai

n C

ircu

it

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Out 3(74E)

(Orange) Out 4(74E)

Max. 125mA

Mai

n C

ircu

it

DC1 to 5V

DC10.8V to 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Analog

OptionLoad

Load

D1

ZD1ZD2

1KZD3

Tr1

Tr2+

DC10.8V to 30V

+

Mai

n C

ircu

it

Max. 125mA

Max. 125mA

Or Tr

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Digital INOption

D1

ZD1

ZD2

Tr1

Tr2

Load

Load

Internal Circuit

MPS-71 & MPS-74 NPN / PNP Open Collector

PNP Open Collector Analog Out

PNP Open Collector Reset In

Sensor MalePin Out

MPS-71 Open CollectorMPS-71 Open Collector with Analog or MPS-74 Open CollectorWiring Reset Input WiringPin # Grommet Lead Only Grommet Lead Only1 Brown: 24VDC Brown: 24VDC Brown: 24VDC2 Black: NPN / PNP Open Collector Black: NPN / PNP Open Collector Black: NPN / PNP Open Collector3 Blue: 0VDC Blue: 0VDC Blue: 0VDC4 White: NPN / PNP Open Collector White: NPN / PNP Open Collector White: NPN / PNP Open Collector

Pink: Analog 1 to 5VDC or Reset Pink: NPN / PNP Open CollectorInput 1 to 5VDC Orange:NPN / PNP Open Collector

2

1

4

3

Brown V+Blue 0VBlack NPN / PNP Open CollectorWhite NPN / PNP Open CollectorPink NPN / PNP Open CollectorOrange NPN / PNP Open Collector

pneu

air

e

Page 61: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

61 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

1.18(30)

1.14 (29)

.79(20)

1.18(30)

.65(16,5)

.20(5)

2- M3

1.18(30)

.20(5)

2- M3

1.57(40)

.98 (25)

1.18 (30)

.41(10,5)

1.57(40) 1 2 3 4

.138 Dia(3,5)

.177 Dia(4,5)

.177 Dia(4,5)

1.18(30)

.98(25)

.23(5,5)

1.46(37)

1.02(26)

.28(7)

.87(22)

.138 Dia(3,5)

1.18(30)

.79(20)

.23(5,5)

1.50(38)

79(20)

.24(6)

.57 (14,6)

.177 Dia(4,5)

.79(20)

.98(25)

.23(5,5)

AMP EI 5-Pin Connector171826-5

AMP EI 5-Pin Connector171825-5

1.37(35)

1.69(43)

.28(7)

.79(20)

1.06(27)

.87(22)

.23(5,5)

.24(6)

.177 Dia(4,5) .79

(20)

.55(14)

1.18 (30)

.79(20)

1.10(28)

.55(14)

.52(13)

.52(13)

CH-2 CH-1

CH-4 CH-3

1.18(30)

.20(5)

2- M3

CH-2 CH-1

CH-4

Reset IN

CH-3

21

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

Multi-Pressure SensorsMPS-7 Display

Catalog 0802-2/USA

Dimensions

DimensionsMPS-71

MPS-74

MPS-ACCK1MountingBracket(Included)

MPS-ACCK3MountingBracket(Included)

pneu

air

e

Page 62: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic62 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

MPS71 Series Programming FeaturesMulti-Pressure SensorsMPS-7 Display

Output Set Openor ClosedEasy ModeActivation

Lock UnlockZero Reset

1

11SelectUnits ofMeasure

10 12 13

SelectPressure

LowPressure

Vacuum PositivePressure

CompoundPressure

Press 9x

HoldPress 1x

PeakValue

BottomValue

Press 3 SecHoldPress 1x

HoldPress 1x

Press 1x Press 1x

7 8 9Display RefreshSettings / OutputResponse TimeInterval

Special DisplayFeatures

Display Peak ValueBottom Value orTheir Difference

Press 6x Press 7x Press 8x

2 3Output Mode 1Hysteresis orWindowComparator

Output Mode 2Hysteresis orWindowComparator

Press 2x Press 4x

4 5 6Output 1Switch PointSetting

Output 2Switch PointSetting

Automatic Teach Mode& Auto Surveillance

VacuumCycle

ReleaseCycle

Press 1x Press 3x Press 5x

Window Comparator Mode Window Comparator Mode

HysteresisMode

HysteresisMode

Low Low

High High

See page 87 for Symbol Explanation

pneu

air

e

Page 63: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

63 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

MPS74 Series Programming FeaturesMulti-Pressure SensorsMPS-7 Display

Output SelectionNormally Open / Normally Closed

Select Remote PressureSelect Unit of Measure

Scan Mode

Lock Unlock

2

3 4

5 6

1 2 3 4

1 2 3 4

Select Output ModeHysteresis or Window ComparatorOutput SettingPeak Surveillance(Repeat Procedure for Each Channel)

Energy Saving ModeDigital IN Mode (Remote Zero Reset)

1 2 3 4

1 2 3 4

1 2 3 4

1

1 2 3 4 1 2 3 41 2 3 4

1 2 3 4

LowPressure

StandardPressure

CompoundPressure

Vacuum

HoldPress 1x

HoldPress 1x

HoldPress 1x

Press 1x

Press 2x

Press and Hold 3 Seconds

Press 1x to Deactivate

3 SecondIntervals

Press 3x

HysteresisMode

WindowComparator

Mode

Low

High

pneu

air

e

Page 64: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic64 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Multi-Pressure SensorsMPS-7 Display

Catalog 0802-2/USA

Accessories

Cables (Applicable to MPS-71E Display Units Only)

Accessories

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

pneu

air

e

Page 65: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

65 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

1.42(36)

(+0.5, -0.2)

1.42(36)

(+0.5, -0.2)

Knockout

1.57(40)

1.72(43,8)

1.57(40)

1.31(33,4)

21

Multi-Pressure SensorsMPS-7 Display

Catalog 0802-2/USA

Accessories

Accessories

1.81(46)

(+0.5, -0.2)

1.81(46)

(+0.5, -0.2)

2.02(53.8)1.97(50)

1.97(50) 1 2 3 4 Knockout

MPS-ACCH5Panel MountingBracket forMPS-74

MPS-ACCH4Panel MountingBracket forMPS-71

pneu

air

e

Page 66: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic66 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Transducer and SensorMPS-8 Mini

Catalog 0802-2/USA

Features

Features• Pressure Ranges:

Vacuum Pressure ...............0 to -30 inHgCompound .................... -14.7 to 72.5 PSI

• Sensor Outputs:1 NPN / PNP Open Collector TransistorOutput, 30VDC, 125mA

1 Analog Output, 1 to 5VDC

• Switch Point 2/3 Trimmer Adjustment

• Fixed Hysteresis 2%

• 10mm Wide

• Compatible with MPS-7 Display

• CE Marked

• Air and Non-Corrosive Gases

MPS-8

Output ModeThe MPS-8 Sensor is 10 mm wide with anNPN / PNP open collector switch output or ananalog output. The MPS-8 can be used incombination with the MPS-7 series display oras a stand alone unit. Analog output isrequired for use with the MPS-7 display.

5

00 Max. Rating

1

Pressure

Ou

tpu

t (V

olt

s)

Fixed2% off off

0

-30 in Hg

on on

S

Switch Output

Analog Output

Model Number Output Pressure Range

MPS-V8B-NG NPN 0 to -30 inHg

MPS-V8B-PG PNP 0 to -30 inHg

MPS-V8U-AG Analog 0 to -30 inHg

MPS-V8U-AGE Analog 0 to -30 inHg

MPS-R8B-NG NPN -14.7 to 72.5 PSI

MPS-R8B-PG PNP -14.7 to 72.5 PSI

MPS-R8U-AG Analog -14.7 to 72.5 PSI

MPS-R8U-AGE Analog -14.7 to 72.5 PSI

pneu

air

e

Page 67: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

67 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

MPS - V 8 B - A G

Pressure RangeV 0 to -30 inHgR** -14.7 PSI to

72.5 PSI**Analog Output

Circuit Only

Port SizeA M5 Through FemaleB M5 Through Female (With Mtg.)C M5 Bottom FemaleU M5 Bottom Swivel MaleT 4mm Tube Stud

Connector / CableG Grommet (2m)GE 2m Grommet Clip Conn.*

* Use with MPS-7 Series Display,Analog Output Only.

Output CircuitA Analog (1-5VDC)N NPN Sinking

OutputP PNP Sourcing

Output

Transducer and SensorMPS-8 Mini

Catalog 0802-2/USA

Ordering Information, Specifications

Media Air and Non-Corrosive GasesPressure Port M5 Female, M5 Male Swivel, 4mm Tube Stud

Proof Pressure V: 72.5 PSI, R: 116 PSIOperating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)Humidity 35 to 85% RH

Electrical Connection G: Grommet Open Lead; GE: Clip Type for use with MPS-7 SeriesPower Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage ProtectionSwitch Output 1 Output, Normally Open, NPN or PNP Open Collector Transistor, 30VDC, 125mALinear Output Analog Output 1 to 5VDC

Switch Point Setting 2/3 TrimmerHysteresis < 2% of F.S. Fixed

Response Time <1msRepeatability < 0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change (Range 32 to 122°F (0 to 50°C)General Protection IP40, CE Marked, EMC rating: EN55011 Class B, EN50082-2

Current Consumption < 20mASpike Protection Vp-p 400v, 0.5ms Surge Protection

Dielectric Strength 1000VAC, 1min.Insulation Resistance > 100M ohms at 500VDCVibration Resistance 10 to 55Hz, 1.5mm amplitude, XYZ, 2 hrs.

Shock Resistance 100 G, XYZMaterial Body: Polycarbonate; Pressure Port: Anodized Aluminum

Mass 0.14 oz. (4g)

Specifications

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 68: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic68 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Mai

n C

ircui

t

D1

Tr1

ZD1 (Blue) OV

(Black) Out 1

(Brown) +V

+

-DC10.8V to 30VLOAD

Max. 125mA

Mai

n C

ircui

t

D1

Tr1 ZD1

(Blue) OV

(Black) Out 1 (N.O.)

(Brown) +V

+

-DC10.8V to 30V

LOADMax. 125mA

Mai

n C

ircui

t

(Blue) OV

(Brown) +V

+

-DC10.8V to 30V(Black) Analog 1 to 5V Output

Transducer and SensorMPS-8 Mini

Catalog 0802-2/USA

Technical Information

Grommet Lead Only Grommet Lead OnlyBrown: 24VDC Brown: 24VDCBlue: 0VDC Blue: 0VDCBlack: NPN / PNP Open Collector Black: Analog 1 to 5VDC

Open Collector Wiring Analog Wiring

Analog

NPN Open Collector

Internal Circuit

CautionsThe MPS-8 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install using the metal mounting base.

PNP Open Collector

pneu

air

e

Page 69: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

69 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Transducer and SensorMPS-8 Mini

Catalog 0802-2/USA

Dimensions

Dimensions

Swivel Joint forManifold Mount

.63(16)

.39(10)

.63(16)

.39(10)

.39(10)

.79(20)

.19(4,75)

.79(20)

.19(4,75)

.41(10,5).82

(20,9)

.83(21)

.12(3) .14 (3,5) Dia.

2-Places.39(10)

.79(20)

.19(4,75)

.31(8)

.16 Dia.Ø (4)

.13 (3,2) Dia.2-Places

.79(20)

.19(4,75)

M5-6

.16(4) .55

(14)

.16(4)

.32(8)

.32(8)

.32(8)

.32(8)

.39(10)

M5-6 M5-6

M5

.83(21)

.79(20)

.19(4,75)

.35(9)

.39(10)

M5-6M5-6

6.56 ft(2m)

Housing(AMP) 171822-5

Connector(AMP) 170204-15

Shield

Grommet Clip Connector(Available for All Models)

MPS-8CM5 Female,Grommet

MPS-8BM5 Female,Grommet

MPS-8UM5 Male Swivel,Grommet

MPS-8AM5 Female,Grommet

MPS-8T4mm Tube Stud

pneu

air

e

Page 70: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic70 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorMPS-9 Thin

Catalog 0802-2/USA

Features

Features• Pressure Ranges:

Vacuum Pressure .............. 0 to -30 inHgCompound ................... -14.7 to 72.5 PSI

• Switch Output:1 NPN or PNP Open Collector, 30VDC,125mA Switch Point

1 Analog Output, 1 to 5VDC

• Switch Point Programming

• Adjustable Hysteresis

• Output Response Time Less Than1.5 Milliseconds

• CE Marked

• Air and Non-Corrosive Gases

MPS-9

hH

off off

0

-30 in Hg

on on

The MPS-9 Sensor with display has onenormally open NPN / PNP open collectoroutput and Analog 1 to 5 VDC Output.

The Switch Output Mode has a switch point(H) programmed by the user at a specificpressure. The Hysteresis Range (h)adjustment controls the output signal 0 to100% below the switch point (H).

Output Modes Switch Output

Model Number Output Pressure Range

MPS-V9M-NGANPN & 0 to -30 inHgAnalog

MPS-V9M-PGAPNP & 0 to -30 inHgAnalog

MPS-R9M-NGANPN & -14.7 PSIAnalog to 72.5 PSI

MPS-R9M-PGAPNP & -14.7 PSIAnalog to 72.5 PSI

5

00 Max. Rating

1

Pressure

Ou

tpu

t (V

olt

s)

Analog Output

pneu

air

e

Page 71: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

71 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

MPS - V 9 M - N GA

Pressure RangeV 0 to -30 inHgR -14.7 PSI to

72.5 PSI

Output CircuitN NPN SinkingP PNP Sourcing

Pressure SensorMPS-9 Thin

Catalog 0802-2/USA

Ordering Information, Specifications

Pressure Range Vacuum Compound

bar: 0.001 bar: 0.01Units of Measure kPa: 0.1 kPa: 1

Display Resolution mmHg: 1 kgf/cm2: 0.01inHg: 0.1 PSI: 0.1

Media Air and Non-Corrosive Gases

Pressure Port M5F

Proof Pressure V: 72.5 PSI, R: 116 PSI

Operating Temperature 32 to 122°F (0 to 50°C)

Storage Temperature 14 to 140°F (-10 to 60°C)

Humidity 35 to 85% RH

Electrical Connection 2m Grommet Open Lead

Power Supply 10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display 3-Digit, 7-Segment LED

Display Refresh 0.2 sec. Fixed

Output Circuit NPN (Sinking) or PNP (Sourcing) Open Collector Transistor, 30VDC, 125mA

Linear Outputs Analog Output 1 to 5VDC

Switch Outputs 1 Switch Output, Normally Open, NPN or PNP, LED Indicator

Output Mode Hysteresis: 0 to 100% of Switch Point Comparative: 2 limits selectable over full range

Output Response Time < 1.5ms

Repeatability ± 0.2% F.S.

Thermal Error 1% over ±25°C (77°C) Temperature Change: Range 32 to 122°F (0 to 50°C)

General Protection IP65, CE Marked, EMC Rating: EN55011 Class B, EN50082-2

Current Consumption < 60mA

Vibration Resistance 10 to 55Hz, 1.5mm, XYZ, 2 hrs.

Shock Resistance 10 G, XYZ

Material Body: Polycarbonate; Pressure Port: Anodized Aluminum

Mass 0.53 oz. (15g)

Specifications

Pressure RangeM M5 Port

Model Number IndexBold Items Are Stocked

pneu

air

e

Page 72: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic72 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorMPS-9 Thin

Catalog 0802-2/USA

Technical Information

Internal Circuit

21

CautionsThe MPS-9 Pressure Sensor is designed to monitor pressureand is not a safety measure to prevent accidents.The compatibility of the sensor is the responsibility of thedesigner of the system and specifications.

Operating Environment• Parker / Convum Sensors have not been investigated for

explosion-proof construction in hazardous environments.• Do not use with flammable gases, liquids, or in hazardous

environments.• Avoid installing the sensor in locations where excessive

voltage surges could damage or affect the performance ofthe sensor.

Operations• Dedicate a power supply of 10.8 to 30VDC to the sensor

and set the ripple to Vp-p10% or less. Avoid excessivevoltage. Avoid voltage surges.

• A small amount of internal voltage drop is possible. Ensurethe power supply minus any internal voltage drop exceedsthe operating load.

• Verify the operating media is compatible with the specifiedsensor. Check the chemical make-up, operatingtemperatures, and maximum pressure ranges of the systembefore installing.

• Installation of air dryer system is recommended to removemoisture.

! Installation• Never insert an object into the pressure port other than an

appropriate fluid connector.• Avoid short-circuiting the sensor. Connect the brown lead to

V+ and blue lead to 0V.• Do not connect the output lead wires (black / white) to the

power supply.• Outputs not being used should be trimmed and insulated.• Install as shown using the metal mounting bracket.

Display Description Solutions

Err Zero Reset Error Reset Zero Below3% of F.S.

Er1 System Error (Internal) Contact Factory

CE1 Over current of Output 1 Load current exceeds

FFF Applied pressure exceeds Apply pressures with–FF pressure range the rating of the sensor

Error Messages

PNP Open Collector with Analog Option

Mai

n C

ircui

t

(Blue) OV

(Brown) +V

+

-DC10.8V to 30V(White) Analog 1 to 5VDC

(Black) OutLOAD

Max. 125mA

500

Mai

n C

ircui

t

(Blue) OV

(Brown) +V

+

-DC10.8V to 30V(White) Analog 1 to 5VDC

(Black) OutLOAD

Max. 125mA

500

NPN Open Collector with Analog Option

Open Collector and Analog WiringGrommet Lead OnlyBrown: 24VDCBlue: 0VDcBlack: NPN / PNP Open CollectorWhite: Analog1 to 5VDC

Brown V+

White Analog 1 to 5 VDC

Blue 0V

Black NPN / PNP Output

pneu

air

e

Page 73: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

73 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorMPS-9 Thin

Catalog 0802-2/USA

Dimensions

2.09(53)

.31(8)

.13 (3.2) Dia.2-Places

.39(10)

.19(5)

.16(4)

.79(20)

.59(15)

.35(9)

PressurePort M5

Dimensions

M5 Female,Grommetpneu

air

e

Page 74: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic74 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Catalog 0802-2/USA

MPS-9 Programming FeaturesPressure SensorMPS-9 Thin

Switch OutputSetting

HysteresisSetting

Lock

Unlock

SelectingUnits of Measure

1 2

3

5

Wait 5 Seconds Wait 5 Seconds

Power Supply Off

4 ZeroReset

NegativePressure

CompoundPressure

kPakPa

bar bar

mmHg kfg/cm2

incHg PSI

Press 1x Press for 3 Seconds

Press for 3 Seconds

Press When Powering Up

Will Displayfor 1 Second

Will Displayfor 1 Second

See page 87 for Symbol Explanation

pneu

air

e

Page 75: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

75 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsCatalog 0802-2/USA

Notes

pneu

air

e

Page 76: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic76 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorSCPSD High Pressure 316 Stainless Steel

Catalog 0802-2/USA

Features

hSP1

off off

0

250 PSI

on on

rSP1

SP1

off

off off250 PSI

0

on on

Switch Output

Window Comparator Output

Output ModesThe SCPSD Sensor has two independentPNP open collector output signals and anoptional analog output. The Switch OutputMode has a switch point programmed by theuser at a specific pressure. The HysteresisRange (h) adjustment controls the outputsignal 0 to 100% below the Switch Point(SP1).The Window Comparator Mode provides twoSwitchpoint Settings (rSP1) and (SP1) thatcontrol the output signals (PNP) between twopressures. This is referred to as the “High /Low” setting.

The optional Analog Output Signal iscalibrated to the pressure scale of the sensor.

Features• Stainless Steel or Ceramic Diaphragms

• UL Listed and CE Marked

• Pressure Ranges-14.7 to 250 PSI 0 to 3000 PSI0 to 1000 PSI 0 to 5000 PSI0 to 2000 PSI 0 to 9000 PSI

• Sensor Outputs2 PNP Open Collector TransistorOutput, 30 VDC, 100mA

Optional Additional Current, 4 to 20mA

• Programming of Switch Point, High / LowValues, NO / NC

• Selectable Units of MeasurePSI, bar, Mpa

• Output Response Time Less than 5.0ms

• M12x1 Micro Connector

• Error Message

• Password Lockable

• Polarity Protected

• Short Circuit Protected

• 4 Digit LED

• Display Swivels 290o

SCPSDpneu

air

e

Page 77: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

77 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorSCPSD High Pressure 316 Stainless Steel

Catalog 0802-2/USA

Ordering Information, Specifications

SpecificationsPressure Range Code 0030P 0100P 0250P 0500P 1000P 2000P 3000P 5000P 9000P

Measuring Range (PSI)-14.7 to -14.7 to -14.7 to 0 to 0 to 0 to 0 to 0 to 0 to

30 100 250 500 1000 2000 3000 5000 9000Overload Pressure (PSI) 87 360 725 1160 2900 4640 7250 11600 21750

Burst Pressure (PSI) 87 360 725 5800 11600 14500 17400 24650 31900Sensing Element Ceramic Stainless Steel

Stainless Steel 1.4404Stainless Steel 1.4404, 1.4542, NBR*

Parts in Contact with Media Ceramic AL203, NBR**FPDM, EPDM Special Request

Switch Cycles >100 MillionOutput Response Time < 10ms

Power Supply 15 to 30VDC, Class 2 Power SupplyElectrical Connection M12 x 1, 4-Pin or 5-Pin

Short Circuit Protection Yes, 2.4 Amp / Open Collector OutputReverse Polarity Protection Yes

Overload Protection YesCurrent Consumption < 100mA

Output Circuit 2 PNP (Sourcing) Open Collector TransistorAnalog Output 0/4…20mA, Programmable, freely scaleable

Output Functions Hysteresis, Window ComparatorSwitching Voltage -1.5vdc

Maximum Current Output 1A with 2 Open Collector Outputs, .5A per outputAccuracy ± 0.5% F.S. Typ., ± 1% Max.

Repeatability ± 0.25% F.S.Display Accuracy ± 0.5% F.S. Typ., ± 1 Digit

Thermal Error Max. ±0.03% F.S. at -4 to 185°F (-20 to 85°C)Material Pressure Die-cast Zinc Z 410: Surface-finishing

Display Material PolyesterPressure Port 7/16-20 UNF-2B (SAE-4)

General Protection IP 67, EN60529, UL, CE Marked, EMC-EN50082-2 Class B, EN 50081-2Temperature Range of Media -4 to 185°F (-20 to 85°C)Ambiant Temperature Range -4 to 185°F (-20 to 85°C)

Storage Temperature -40 to 212°F (-40 to 100°C)Display 4-Digit, 7-Segment LED, Red, 9mm Height

Tightening Torque 35NmVibration Resistance 20G, 10 to 500Hz, IEC60068-2-6

Shock Resistance 50 G, XYZ, 11ms, IEC60068-2-29Mass 10.6 oz. (300g)

Pressure Range0030P -14.7 to 30 PSI0100P -14.7 to 100 PSI0250P -14.7 to 250 PSI0500P 0 to 500 PSI1000P 0 to 1000 PSI2000P 0 to 2000 PSI3000P 0 to 3000 PSI5000P 0 to 5000 PSI9000P 0 to 9000 PSI

Housing2 Metal Housing,

Female Thread

SCPSD - 0250P 0 7 - 2 7

Output0 PNP without 4-20mA

Analog Signal1 PNP with 4-20mA

Analog Signal

Pressure Port*7 7/16-20 UNF

(SAE-4)* BSPP Pressure

Ports are available.Consult Factory forModel Number.

ElectricalConnector

7 4-Pin, M125* 5-Pin, M12

* Output 1 , WithAnalog Signal

Model Number IndexBold Items Are Stocked

(Revised 9/9/04)

pneu

air

e

Page 78: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic78 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorSCPSD High Pressure 316 Stainless Steel

Catalog 0802-2/USA

Technical Information

Internal Circuit

BlackBlack

WhiteWhite

Gray

BlueBlue

M12, 5-Pin, 2 PNP Outputs with 4 to 20mA AnalogM12, 4-Pin, 2 PNP Outputs

M12, 4-Pin, PNP Output with 4 to 20mA Analog

1

1

4

2

5

1

4

2

33

2

4

5

3

(Sensor Socket)

Brown Brown

1 2

4 3

(Sensor Socket)

0V / Gnd0V / Gnd

S1

S2

S1

S2

+Ub (24VDC)+Ub (24VDC)

Black

White

Blue

1

4

2

3

(Sensor Socket)

Brown

1 2

4 3

0V / Gnd

S1

Analog Out

+Ub (24VDC)

Analog Out

InstallationMechanical:

CAUTION: Install and de-install the SCPSD onlywhen there is no pressure present.

Attach the SCPSD to the appropriate process connection.Installation should be undertaken only with a 22mm, acrossflats spanner. Ensure that the digital display is placed in thebest viewing position by using the rotational housingadjustment. Turn the SCPSD manually to the requiredposition. Maximum 290°.

Excessive turning beyond the easily detectable end stop willlead to damage.

The housing can be attached:• with self-tapping screws into two blind holes at the back of

the housing• with the mounting plate provided• with cable ties

Electrical:CAUTION: The SCPSD may be installed only by aqualified electrician in accordance with therespective national and international regulations.

Protect the SCPSD from electomagnetic influences andover-voltages.

Optional installation tips which are shown by experience toreduce the influence of interference:• Use shorter cables• Avoid short distances between connecting leads and

power consuming devices and interference generatingelectrical and electronic equipment

• Use free running diodes

!

!

Avoid static and dynamic over-pressures which exceed thespecified overload pressure. Even when the overloadpressure is exceeded only for a short time the SCPSD maybe damaged. Parker SensoControl diagnostic systems arerecommended for measuring pressure peaks exactly.

If there is a danger of excessively high pressure peaks, it isrecommended to:• use an SCPSD with a higher nominal instrument

pressure (analog output can then be correspondinglymatched)

• install a standard throttling device upstream from theSCPSD

Error Messages

Display Description

Att The set value is lower than the other respectiveparameters. When Enter is activated, the smaller valueis matched up.

Err1 System Error (Internal)

Err2 Nominal instrument pressure range was exceeded by10%. Please check system pressure.

Err3 Nominal instrument pressure range has been exceeded.Error in analog electronics. Please check systempressure.

Note: M12, 5-Pin Female Cable Connector will fit on both M12,4-Pin and 5-Pin Male Sensor Connector.

pneu

air

e

Page 79: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

79 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorSCPSD High Pressure 316 Stainless Steel

Catalog 0802-2/USA

Accessories

.38 Ref.(9.7mm)

.57 Dia. Ref.(14.5mm)

M12x1

1.84 Ref.(46.7mm)

1.50 Ref.(38.1mm)

6.56 ft(2m)

CB-M12-5P-2M, Female to Open Lead CB-M12-4P-2M, Female to Open Lead

CB-M12-5P-M12-2M, Female to MaleCB-M12-4P-M12-2M, Female to Male

.57 Dia.(14.48mm)

.57 Dia.(14.48mm)

M12x1

1.84(46.7mm)

2.02(51.3mm)

6.56 ft(2m)

4-Pin5-Pin

4-Pin5-Pin

4-Pin5-Pin

Male Interface4-Pin, M12

3421

Male Interface5-Pin, M12

34 5

21

Female Interface4-Pin, M12

3 42 1

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Female Interface5-Pin, M12

3 45

2 1

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

5 Gray

Cables (IP 67 Rated)

CB-M12-5P-2M-90

.57 Dia.(14.48mm)

1.22(31mm).98

(25mm)

1.53(38.8mm)

6.56 ft(2m)

Female Interface5-Pin

3 45

2 1

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

5 Gray

Dimensions

UNIT

SensoControl

1.56(39.5)

1.82(46.3)

3.89(98.5)

2.89 (73.4)

.55(14)

7/16-20 UNF-2B (SAE-4)

.98(25)

I II

Switch Output 2(Also Error Output)Switch Output 1

1.06(26.8)

1.26(32)

pneu

air

e

Page 80: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic80 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorSCPSD High Pressure 316 Stainless Steel

Catalog 0802-2/USA

Programming Features

Right Page

Menu

YesPass-word

( ) or ( )

Parameters Shown inDigital DisplayTo program switch outputs in menu S1 (S1 = output 1) or S2 (S2 =output 2), press and hold, then press . Pro6 will be displayedfor 2 seconds.

PRS This is dedicated to a password. Entry into the programmingmode can be secured only when the correct figures have beenentered

Menu for programming the switch outputs:S1 S1 = Switch output 1S2 S2 = Switch output 2 (Menu is not active if S2 is being used as

an error output)

Switching point (SP): upper limiting value / pressure, at whichthe switch output changes its status.

SP1 SP1 = Switch output 1; input as pressure value (e.g. 400 bar)SP2 SP2 = Switch output 2; input as pressure value (e.g. 430 bar)

rSP1 Reverse switching point (rSP): lower limiting value/pressureat which switch output changes its status.

rSP2 rSP1 = Reverse switching point (rSP1) of switch output 1;input as pressure value (e.g. 390 bar)rSP2 = Reverse switching point (rSP2) of switch output 2;input as pressure value (e.g. 420 bar)The reverse switching point is always smaller than itsrespective switching point. If the reverse switching point is sethigher than the switching point, the reverse switching point willbe set automatically 0.5% of the instrument nominal pressurebelow the switching point. The warning sign Att (attention) willappear, which can be cleared with Enter.

cont Switch output asnoPn = closernCLS = opener

Func Selection of switching functions:HySt = Hysteresis functionFEn = Window function

Delay times; input from 0 to 9.99 s.dSPI dSPI = delay time switching point output 1drSL drSI = delay time reverse switching point output 1dSP2 dSP2 = delay time switching point output 2drS2 drS2 =delay time reverse switching point output 2

Options Program (See Next Page)

To Program Outputs and Options of SCPSD, press and hold the(Up Arrow Icon) then press the (Circle Icon) until Pro6 isdisplayed. Release all buttons and follow menu to program outputsand options.

To Review Programed Outputs and Options of SCPSD, press andhold the (Circle Icon) until Pro6 is displayed. Release the(Circle Icon) and follow menu to program option and status.

pneu

air

e

Page 81: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

81 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorSCPSD High Pressure 316 Stainless Steel

Catalog 0802-2/USA

Programming Features & Dimensions

SUn Indication of Software Version

dPP Setting of the decimal point. (The maximum number of decimalpoints depends on the nominal pressure of the SCPSDinstrument)0000 = no decimal point000.0 = 1 decimal point00.00 = 2 decimal points0.000 = 3 decimal points

End End of programming mode

0Set Zero adjustment: The actual pressure will be stored as a newzero point. For safety reasons this is limited to the range ± 5%of the nominal instrument pressure. Application example: asystem with a continuous residual pressure, but which shouldbe displayed as 0 bar.OFF = factory calibrationyES = undertake zeroing adjustment nowno = go back to the menu and do not make any new zeroingadjustments. After a zeroing adjustment, a pressure of up to20 bar can be displayed as 0 on a 400 bar SCPSD. Beforeworking on a system, it must be ensured that there is nopressure in it.

rES Clearing the minimum and maximum value memoryyES = yes, clear memory nowno = no, do not clear memory

Err Programming switch output 2 as an error outputyES = yesno = noSwitch Output 2 can be used optionally as an error output todisplay pressure switch function errors. As an error output it isnormally closed, and in case of errors (Err 1, Err 2, Err 3) it isopen. At the same time LED II lights up. The display and theoutput remain active until the error is cleared.

!

Settings for Options ProgramoP Options program

PA5 Password input0000 = no passwordExample password 1234 = 1234

uni Setting of units:bAr = bar NPA= MPa PSi= PSI

diS Display: Value which will be shown on the digital display in runmode.Act = Actual system pressureNin = Minimum system pressure; (pressure troughs)NA = Maximum system pressure; (pressure peaks)SPl = Switch point 1SP2 = Switch point 2OFF = off indication

AnA Setting of analog output (see point 4)0-20 = 0-20 mA 4-20 = 4-20 mA

FroN Calibration of starting value (0 or 4 mA) for the analog output.Settable from 0 to nominal instrument pressure.Example for AnA = 4-20:0000 = at 0 bar the analog output yields 4 mA.The starting value is always smaller than the end value. If thestarting value is set greater than the end value, then thestarting value will be automatically set 5% of the nominalinstrument pressure below that of the end value. The warningsign Att 1 will appear, which can be cleared with the Entersign.

to Calibration of end value (20mA) for the analog output.Settable from 0 up to nominal instrument pressure.0010 = at 10 bar the analogue output yields 20 mA.

!

Electrical Test Unit (M12, 5-Pin)SCSN-450-PSD

SCPSD Programming KitSCSD-PRG-KIT

Optical Interface Device that allows read / write andstoring of SCPSD configuration data. Kit includesoptical interface device, electrical test unit with PCcable (RS232 connector) and software.

OpticalInterfaceDevice

SCPSDpneu

air

e

Page 82: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic82 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

.38 Ref.(9.7mm)

.57 Dia. Ref.(14.5mm)

M12x1

1.84 Ref.(46.7mm)

1.50 Ref.(38.1mm)

6.56 ft(2m)

CB-M12-5P-2M, Female to Open Lead CB-M12-4P-2M, Female to Open Lead

CB-M12-5P-M12-2M, Female to MaleCB-M12-4P-M12-2M, Female to Male

.57 Dia.(14.48mm)

.57 Dia.(14.48mm)

M12x1

1.84(46.7mm)

2.02(51.3mm)

6.56 ft(2m)

4-Pin5-Pin

4-Pin5-Pin

4-Pin5-Pin

Male Interface4-Pin, M12

3421

Male Interface5-Pin, M12

34 5

21

Female Interface4-Pin, M12

3 42 1

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Female Interface5-Pin, M12

3 45

2 1

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

5 Gray

Pressure SensorsAccessories

Catalog 0802-2/USA

Pressure Sensor Cables

Common Part NumbersItem Connector Contacts Length Cover

CB-M8-4P-2M M8 Female 4 2m PVCCB-M8-4P-5M M8 Female 4 5m PURCB-M8-4P-5M-90 M8 Angled Female 4 5m PURCB-M8-4P-M12-2M M8 Female to M12 Male 4 2m PVCCB-M8-4P-M8-2M M8 Female to M8 Male 4 2m PVCCB-M8-4P-2E M8 Female 4 2m PVCCB-M12-4P-2M M12 Female 4 2m PVCCB-M12-5P-2M M12 Female 5 2m PVCCB-M12-5P-2M-90 M12 Female 5 2m PVCCB-M12-4P-M12-2M M12 Female to M12 Male 4 2m PVCCB-M12-5P-M12-2M M12 Female to M12 Male 5 2m PVC

Features• M8, M12 Male / Female Connector

• Length: 2m or 5m

• Cover: PVC or PUR

• Connection Type: Swivel Straight orAngled

• IP 67 Swivel Connector

.196 (5) Dia

6.56 ft(2m)

6.56 ft(2m)

1.26(32)

CB-M8-4P-2M, Female to Open Lead

CB-M8-4P-5M, Female to Open Lead CB-M8-4P-M8-2M, M8 Female to M8 Male

CB-M8-4P-2E, M8 Female

CB-M8-4P-M12-2M, M8 Female to M12 Male

CB-M8-4P-5M-90, Female to Open Lead

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

1.26(32)

.38(9,7) Dia

.69(17)

.47(12) Dia

.38(9,7) Dia

.196 (5) Dia

6.56 ft(2m)

1.26(32)

2.09(53)

6.56 ft(2m)

.38(9,7) Dia

.196 (5) Dia

.196 (5) Dia

.38(9,7) Dia

16.40 ft(5m)

.87(22)

.42(10,7)

.75(19)

Housing(AMP) 171822-5

Connector(AMP) 170204-15

Shield

Female Interface4-Pin, M8

2 4

1 3

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

Male Interface4-Pin, M8

24

13

Male Interface4-Pin, M12

3421

CB-M12-5P-2M-90

.57 Dia.(14.48mm)

1.22(31mm).98

(25mm)

1.53(38.8mm)

6.56 ft(2m)

Female Interface5-Pin

3 45

2 1

Cable Pin Color

1 Brown

2 White

3 Blue

4 Black

5 Gray

pneu

air

e

Page 83: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

83 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsAccessories

Catalog 0802-2/USA

Panel Mounting Kits

MPS-ACCH1, MPS-ACCH7, MPS-ACCH4

MPS-ACCH5

1.57(40)

1.72(43,8)

1.57(40)

1.31(33,4)

1.42(36)

(+0.5, -0.2)

1.42(36)

(+0.5, -0.2)

Knockout21

1.81(46)

(+0.5, -0.2)

1.81(46)

(+0.5, -0.2)

2.02(53.8)1.97(50)

1.97(50) 1 2 3 4 Knockout

Description For Use With

MPS-ACCH1MPS-3 Stainless Steel

MPS-4

MPS-ACCH7MPS-3

MPS-31

MPS-ACCH4 MPS-71

MPS-ACCH5 MPS-74

Panel Knockout Dimensions

pneu

air

e

Page 84: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic84 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsTechnical Data

Catalog 0802-2/USA

Technical Information

Solid State SensorsIntroductionElectromechanical pressure sensors convert the appliedpressure to an electrical signal. When pressure is applied,the diaphragm is deflected causing the diffused resistors tochange resistance (piezoelectric effect), which yields anelectrical signal proportional to the pressure change.Applications for pressure switches are numerous andimportant in today's high-tech manufacturing environment.

Silicon DiaphragmThis type of sensor is used for air and non-corrosive gasapplications.

5

00 Max. Rating

1

Pressure

Ou

tpu

t (V

olt

s)

20

4

Ou

tpu

t (m

A)

Analog Output

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

Silicon Diaphragm

Sensor Module

Pressure

Base

SemiconductorPressure Element

BodySUS 316L

Pressure

Stainless SteelDiaphragmSUS 316L

orSUS 630

Stainless Steel DiaphragmThis type of sensor is used for liquids, non-corrosive to 316Lor 630 stainless steel.

Difference Between Switch Outputand Analog Output TypeSwitch OutputThis is an NPN / PNP Open Collector transistor Output that“sinks” or “sources” the signal when the pressure switchpoint is achieved. The switch point is set by programming orpotentiometer trimmer adjustment.

Window ComparatorWindow Comparator provides two switch points at differentpressures to activate the NPN / PNP open collectortransistor outputs.

Analog OutputAn analog output provides an output voltage that isproportional and linear to the pressure measured by thesensor. This output signal provides continuous feedback tothe analog card of the PLC.

pneu

air

e

Page 85: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

85 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsTechnical Data

Catalog 0802-2/USA

Technical Information

Mai

n C

ircu

it

DC1 to 5V

Max. 125mA

Max. 125mA DC10.8V to 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Analog

Option

Load

Load

D1

ZD1

ZD21K

ZD3

Tr1

Tr2+

Mai

n C

ircu

it

Max. 125mA

Max. 125mA

Or Tr

DC10.8V to 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Digital INOption

D1

ZD1

ZD2

Tr1

Tr2

+

Load

Load

Max. 125mA

Mai

n C

ircu

it

DC1 to 5V

DC10.8V to 30V

(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Analog

OptionLoad

Load

D1

ZD1ZD2

1KZD3

Tr1

Tr2+

DC10.8V to 30V

+

Mai

n C

ircu

it

Max. 125mA

Max. 125mA

Or Tr(Brown) +V

(Blue) OV

(White) Out 2

(Black) Out 1

(Pink) Digital INOption

D1

ZD1

ZD2

Tr1

Tr2

Load

Load

NPNNPN type open collector transistor outputs are solid statecircuits that provide sinking output capabilities. When thetransistor is on, the current for the load flows into thetransistor. This output “sinks” toward 0VDC, 0mA.

NPN Output (With Analog Output)

NPN Output (With Reset IN)

PNPPNP type open collector transistor outputs are solid statecircuits that provide sourcing output capabilities. When thetransistor is on, the current for the load flows out of thetransistor. This output “sources” toward 24VDC, 125mA.

PNP Output (With Analog Output)

PNP Output (With Reset IN)

Difference Between NPN and PNP Output

Reset Input Option ( MPS-71 Only)

By sending a 5VDC signal to the sensor, it is possible toautomatically reset the sensor to ambient zero when smallfluctuations in the system or atmosphere influence thebeginning reference point.

H

Fluctuation

NegativePressure

OK NG

IN

H

Digital Set

NegativePressure

OK OK

IN IN IN

Flashing display of AL is displayed when thedigital IN signal is entered.

pneu

air

e

Page 86: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic86 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsTechnical Data

Catalog 0802-2/USA

Technical Information

Output ModesSwitch Point with Hysteresis SettingsThis output mode provides one switch point (H) and ahysteresis pressure adjustment. When the switch pointpressure is achieved, the output (NPN / PNP) is activated ifnormally open or deactivated if normally closed. Typically,this mode is used for pressure confirmation. For positivepressure applications, this operating mode does not provideany output or alarms beyond the switch point in the case ofexcessive pressures.The hysteresis setting (h) is the difference in pressure belowthe switch point pressure which controls the on / off status ofthe output.

Window Comparator SettingThis output mode provides two switch points (A) and (b) thatcontrol the output signals (NPN / PNP) between the twopressures. This creates a “window” that the sensor canprovide an output and is sometimes referred to as “high /low” setting. The window comparator Mode provides anoutput or alarm when pressures exceed the upper limit.

hH

off off

0

-30 in Hg

on on

A

b

off

off off-30 in. Hg

0

on on

RepeatabilityThe repeatability refers to the sensor’s ability to provide thesame output with consecutive applications of the samepressure input.

Repeatability is represented as a percentage of the fullscale value of the sensor. All Parker / Convum sensors arerated ± 0.2% F.S. P

1 would be represented as 145 PSI x

0.002 = ±0.29 PSI.

AccuracyThe PERCENTAGE difference between the true value andthat indicated by an instrument is the measure of theinstrument’s accuracy. It is expressed as a percentage of thefull-scale value of the reading according to the type ofinstrument.

Display ResolutionThe least possible unit increment shown on the display.

IP RatingsIP40 - Protected against solid foreign objects of 0.04"

(1mm) and greater.Non-protected against the penetration of liquids.

IP65 - Dust tight.Protected against water jets.

IP67 - Dust tight.Protected against the effects of temporaryimmersion water.

Rep

eata

bili

ty

PressureP1

+

Reading

Pressure Unit TableUnits

UnitsPa bar PSI kgf/cm2 atm mm H2O in H2O mm Hg in Hg

Pa 1 10-5 0.145x10-3 1.0197x10-5 0.987x10-5 0.10197 0.402x10-2 0.750x10-2 0.295x10-3

bar 105 1 14.5038 1.01972 0.98692 10197.16 401.46 750.062 29.53

PSI 6894.76 0.06895 1 0.07031 0.6805 703.07 27.68 51.715 2.036

kgf/cm2 98066.5 0.9807 14.2233 1 0.96784 10000 393.70 735.56 28.96

atm 1.013x10-5 1.01325 14.696 1.03323 1 10332 406.77 760 29.92

mm H2O 9.807 0.098x10-3 0.00142 0.0001 0.097x10-3 1 0.0394 0.07355 0.29x10-2

in H2O 249.09 0.249x10-2 0.0361 0.00254 0.246x10-2 25.4 1 1.868 0.07355

mm Hg 133.322 0.00133 0.01934 0.00136 0.00132 13.5951 0.535 1 0.0394

in Hg 3386.4 0.03378 0.4912 0.0345 0.03353 345.32 13.589 25.4 1

pneu

air

e

Page 87: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

87 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsCatalog 0802-2/USA

Programming Symbols Legend

Output 1

Output 3

Output 2

Output 4

Output Normally Closed (Passing)

Output Normally Open (Non-Passing)

Pressure Units (Pascal).Negative Units for Vacuum Sensors

Pressure Units (Bar).Negative Units for Vacuum Sensors

Pressure Units (mm.Hg).Negative Units for Vacuum Sensors

Pressure Units (in.Hg).Negative Units for Vacuum Sensors

Pressure Units (kgf/cm2).Negative Units for Vacuum Sensors

Pressure Units (PSI)

Easy Mode. Sensor will only allow changes to set points

Off, or Energy Saving Display; reduces current consumption of Sensor

On

Hysteresis Mode. Select Hysteresis Set Point and Hysteresis Range

Windows Comparative ModeSelect High and Low Set Point

Hysteresis Mode Set Point. Output 1

Hysteresis Mode Set Point. Output 2

Hysteresis Mode. Hysteresis Range Output 1

Hysteresis Mode. Hysteresis Range Output 2

Windows Comparative ModeLow Set Point Output 1

Windows Comparative ModeHigh Set Point Output 1

Windows Comparative ModeLow Set Point Output 2

Windows Comparative ModeHigh Set Point Output 2

Automatic Teach Mode. Automatically sets Outputs 1 and 2 while cycling system. Output 1 set to Hysteresis Mode, Output 2 set to Window Comparative Mode

Auto Surveillance Mode On/Off. Set after Automatic Teach

Auto Surveillance based on cycles times. Provides output if Peak Value is not obtained in a specified number of cycles. (1-100)

Display Refresh Setting. Display updates from .1 to 1 sec. .3 sec factory set. Does not affect Sensor Response Time

Output Response Time. Multiples the sensor response time. Increases sensor response time. (Anti-chatter Mode)

Pressure Value Display Mode. Displays Pressure for a specific time period and then updates for next time period

Time Range for Pressure Value Display Mode

Value Setting for Pressure Value Display Mode

Display Peak Value over selected time range

Display Bottom Value over selected time range

Display Difference over selected time range

Display Function Mode. On/Off

Display Function. Selects display types.

Display blinks pressure when Output 1 is Passing Normal when Output 1 is Non-Passing

Display blinks pressure when Output 2 is Passing Normal when Output 2 is Non-Passing

Display shows pressure when Output 1 is PassingDisplay shows special screen when Non-Passing

Display shows pressure when Output 2 is PassingDisplay shows special screen when Non-Passing

Select Switch Output setting for MPS-31

Color Setting for MPS-31

MPS-4, Port Reference Selection

MPS-4, Display change of B port to A port static

MPS-4, Display change of A port to B port static

MPS-4, Display change of A port to change of B port

MPS-7, Pressure Range Selection Vacuum

MPS-7, Pressure Range Selection Low Pressure

MPS-7, Pressure Range Selection Positive Pressure

MPS-7, Pressure Range Selection Compound Pressure

MPS-7, Energy Savings Mode, reduces current consumption

MPS-7, Peak Surveillance

Digital Input Sensors Only. Digital Input Mode for remote Zero reset of sensors

Digital Input

Digital Channel

MPS-7 Scan Mode. Sensor scans and displayseach channel for 3 sec.

Locked. Sensor programs cannot be changed

Unlocked. Sensor programs can be changed

Sets Sensors reference point to current atmospheric conditions

Zero Resetpneu

air

e

Page 88: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic88 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsCatalog 0802-2/USA

Glossary

__A__AccuracyThe PERCENTAGE difference between the true value andthat indicated by an instrument is the measure of theinstrument’s accuracy. It is expressed as a percentage of thefull-scale value of the reading according to the type ofinstrument.

Analog OutputA voltage (1 to 5VDC) or current (4 to 20mA) output that iscalibrated and proportional to the operating pressure of thesensor.

Automatic Surveillance ModeSensor automatically surveys vacuum cycle to determine ifthe Peak Vacuum Level was attained after H-1. Output 2changes state if the Peak Vacuum Level of the system is notreached over a consecutive number of surveillance’sprogrammed. Up to 100 consecutive cycles can beprogrammed.Peak Vacuum Level and number of surveillance’s areprogrammed at the end of the Automatic Teach Mode.

Automatic Teach ModeProgramming feature that automatically sets switch pointsduring the vacuum cycle.Sets Output 1 to Hysteresis Mode and Output 2 to WindowComparator Mode. 60% of maximum vacuum level displayedduring setup operation of the system.

Output 1: Hysteresis ModeH-1 = (Peak Vacuum Level minus Bottom Vacuum Level)

x 0.6 + Bottom Vacuum Levelh-1 = (H-1) x 0.05

Output 2: Window Comparator ModeA-2 = (H-1) x 0.8B-2 = Peak Vacuum Level x 0.8

__C__Cable Connector Type4-Pin, M8 cable connector referred to as PICO or Microconnector. 4-Pin, 5-Pin, M12 cable connector referred to asMini connector.

Channel SelectionThe MPS-74 display allows the user to select up to 4separate channels to monitor remote sensors.

Class 2 Power SupplyPower source not exceeding 30VDC and 8 amps.

Connection Port SizePressure port connections on the back or bottom of thesensor.

Current ConsumptionMaximum current consumed during operation. Does notinclude the load current.

__D__

Display ResolutionResolution is 1/1024. The least possible measurable unit todisplay on the display. This will vary with the units of measureand is adjustable on some sensors.Shown below are the different unit increments displayed fordifferent pressures.

Compound Low Pressure Vacuum Pressure

bar: 0.01 bar: 0.001 bar: 0.001 bar: 0.01

kPa: 1 kPa: 0.1 kPa: 0.1 mPa: 0.001

kgf/cm2: 0.01 kgf/cm2: 0.001 mmHg: 1 kgf/cm2: 0.01

PSI: 0.1 PSI: 0.1 inHg: 0.1 PSI: 1

Dielectric StrengthSensors ability to withstand excess voltages.

Digital Display UnitMinimum unit displayed on the sensor.

DIN RailA rail mounting bracket equivalent to DIN Standard,adaptable to the MPS-2 sensors.

__E__Error MessageError message is displayed if the pressures, inputs, oroutputs exceed the parameters of the sensor.

__F__Full ScaleAbbreviated as F.S. this is the operating pressure scale of thesensor.

__G__Grommet TypeElectrical lead from the sensor.

__H__HysteresisThe difference in pressure below the switch point pressurewhich controls the ON-OFF status of the output signal.

__I__

Input ImpedanceThe source of the electrical response of the sensing elementexpressed in ohms.

IP RatingsIP40 - Protected against solid foreign objects of 0.04"

(1mm) and greater.Non-protected against the penetration of liquids.p

neu

air

e

Page 89: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic

C

89 Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsCatalog 0802-2/USA

Glossary

IP65 - Dust tight.Protected against water jets.

IP67 - Dust tight.Protected against the effects of temporaryimmersion water.

Insulation ResistanceResistance between electrical circuit and the body,expressed in ohms at a voltage rating.

Internal Voltage DropCaused by the resistance of an electrical part in an electroniccircuit. Example is a 2-wire pneumatic pressure switch.

__L__

LEDElectronic Display Technology

Load CurrentAmount of current flowing through the sensor once the outputis activated.

Lock-Out ModePrevents accidental changes to the sensor settings.

__M__

Maximum Operating PressureMaximum operating pressure the sensor is rated for.Exceeding this pressure could damage the unit and willdisplay FFF.

__N__

Noise ResistanceAmount of electrical noise in the surrounding environmentthat could affect the sensor performance.

NPN OutputReferred to as a sinking open collector transistor output. Theoutput sinks toward "0VDC" when activated.

__O__

ON / OFF OutputThe electrical state of the output signal.

Open Collector TransistorOutput circuit that sinks (NPN) or sources (PNP) at thepressure switch-point setting.

Operating Humidity RangeHumidity range for proper operation of equipment.

Operating Indicator LightLED indicator is on when ON-OFF output is ON.

Operating Pressure RangeThe pressure range the unit was designed to operate in.

Operating Temperature RangeAcceptable temperature range for the specifications listed inthe catalog.

Operating VoltageVoltage range for normal operation.

Output Response TimeResponse time of the output signal after the pressure switchpoint is achieved. Measured in milliseconds.

Output SettingsMaximize the difference between the “Part -Off” and “Part-On”vacuum levels by selecting the appropriate tubing I.D. andlength from the generator to the cup. The part present outputmust be set between the “Part -Off” and “Part-On” vacuumlevels. If the difference between the “Part -Off” and “Part-On”vacuum levels is minimal, remote sensing at the suction cup isrecommended with MPS-6 or MPS-8 sensors.

For most material handling applications, the part presentoutput can be set near the upper limit of the output range.

For high speed pick and place applications, the part presentoutput can be set near the lower limit of the output range. Thisreduces the output response time of the sensor. Outputresponse and accuracy are critical to the overall performanceof the system. Remote sensors are recommended here.

__P__

Panel Mounting BracketsBrackets used to panel mount the sensor.

0 100 200

-30inHg “Part-On”

Vacuum Level

“Part-Off”Vacuum Level

Output Range

Upper Limit

Lower Limit

Output Response Time (msec)

pneu

air

e

Page 90: Pressure Sensors e - SMC Pneumatics U.S.A · PDF fileMedia IP Output Mode Setting Display Number Rating Adjustment MPS-1 0 to 145 PSI (1) NPN / PNP Air, Variable, 0 to -30inHG

Pneumatic90 Parker Hannifin Corporation

Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pressure SensorsCatalog 0802-2/USA

Glossary

Peak SurveillanceMaintenance function that can monitor peak values of thesystem. During the pressure cycle, if peak pressure (P-1) isnot attained after set point (H-1)is attained, an error codePErr is displayed on the sensor.

PNP Output TypeReferred to as a sourcing open collector transistor outputwhere the voltage sources toward "24VDC" when activated.

__R__

RepeatabilitySensor's ability to reproduce pressure output represented bya percentage of the sensor's full scale.

Reverse Voltage ProtectionDiode circuitry to prevent "cross-wire" damage duringinstallation of the sensor.

__S__

SetpointsThe number of the ON-OFF output signals in one product.Product with 2 setting points means 2 output type.

Shock ResistanceThe amount of vibration the sensor can withstand withoutaffecting performance.

Switch OutputThis is a reference to a digital or NPN / PNP open collectortransistor output from the sensor. The technology is binarylogic.

__T__

Thermal ErrorTemperature characteristics vary with applications. Theperformance of the sensor can be affected by changes inambient temperatures. The sensor rating is represented by apercentage of the F.S.

__W__

Wetted PartsSensor body parts that are in contact with process-type fluidsare refered to as wetted parts.

h-1P-1PeakValue

H-1

0

-30 in Hg

Window Comparator ModeSensor output mode with two switch-point pressure outputsthat control the output signals (NPN / PNP) between the twopressure settings. This is sometimes referred to as the "High /Low" setting.

__Z__

Zero ResetThe sensor technology is PSIA. Periodically, the sensor'satmospheric reference may need to be adjusted manually orautomatically as a result of small changes in the atmosphericreference point.

pneu