PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code Voltage and Current Requirements Conductors and Wiring Methods

Embed Size (px)

Citation preview

Page 1: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods
Page 2: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

PowerPoint® PresentationPowerPoint® Presentation

Chapter 11Chapter 11Electrical IntegrationElectrical Integration

National Electrical Code • Voltage and Current Requirements •

Conductors and Wiring Methods • Overcurrent Protection • Disconnects •

Grounding • Battery Systems

National Electrical Code • Voltage and Current Requirements •

Conductors and Wiring Methods • Overcurrent Protection • Disconnects •

Grounding • Battery Systems

Page 3: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Many articles in the NEC® are applicable to the electrical integration of a PV system, particularly Article 690.

Many articles in the NEC® are applicable to the electrical integration of a PV system, particularly Article 690.

Page 4: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

The NEC® defines the various circuits and components in PV systems and specifies their requirements.

The NEC® defines the various circuits and components in PV systems and specifies their requirements.

Page 5: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Array open-circuit voltage is corrected for low temperatures to yield the maximum possible PV circuit voltage.

Array open-circuit voltage is corrected for low temperatures to yield the maximum possible PV circuit voltage.

Page 6: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Conductor sizes typically used in PV systems range from 18 AWG to 4/0 AWG. Conductors may be solid or stranded. Larger conductors have lower resistance for a given length.

Conductor sizes typically used in PV systems range from 18 AWG to 4/0 AWG. Conductors may be solid or stranded. Larger conductors have lower resistance for a given length.

Page 7: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Ampacity is the current-carrying capacity of a conductor, which depends on the conductor’s type, size, and application.

Ampacity is the current-carrying capacity of a conductor, which depends on the conductor’s type, size, and application.

Page 8: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Conductor ampacity must be derated for high operating temperatures.

Conductor ampacity must be derated for high operating temperatures.

Page 9: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

For conduits installed on rooftops, an extra temperature adder is needed to account for the extreme ambient temperatures of the environment. The adjusted ambient temperature is then used to determine the temperature-based ampacity correction factor.

For conduits installed on rooftops, an extra temperature adder is needed to account for the extreme ambient temperatures of the environment. The adjusted ambient temperature is then used to determine the temperature-based ampacity correction factor.

Page 10: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Conductor ampacity must be derated for more than three current-carrying conductors together in a conduit or cable.

Conductor ampacity must be derated for more than three current-carrying conductors together in a conduit or cable.

Page 11: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Information printed on the outer jacket of a conductor includes size, insulation type, environmental exposure, temperature ratings, and listing approval.

Information printed on the outer jacket of a conductor includes size, insulation type, environmental exposure, temperature ratings, and listing approval.

Page 12: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Conductors in different parts of a PV system have different application requirements.Conductors in different parts of a PV system have different application requirements.

Page 13: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Source-circuit conductors for PV module interconnections within the PV array are permitted to be exposed if the conductor insulation has the required environmental resistances.

Source-circuit conductors for PV module interconnections within the PV array are permitted to be exposed if the conductor insulation has the required environmental resistances.

Page 14: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Modules are typically connected together in PV source circuits with external, exposed connectors.

Modules are typically connected together in PV source circuits with external, exposed connectors.

Page 15: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

When tightened and torqued properly, screw terminals produce secure and low-resistance connections.

When tightened and torqued properly, screw terminals produce secure and low-resistance connections.

Page 16: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Lugs are crimped conductor terminations in ring, fork, spade, or pin shapes.Lugs are crimped conductor terminations in ring, fork, spade, or pin shapes.

Page 17: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Splicing devices, such as screw terminal blocks, are used in PV systems to connect or extend conductors or to parallel array source circuits. This type of terminal would not be used for a tap.

Splicing devices, such as screw terminal blocks, are used in PV systems to connect or extend conductors or to parallel array source circuits. This type of terminal would not be used for a tap.

Page 18: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Several NEMA plug-and-receptacle configurations are acceptable for use with DC branch circuits.

Several NEMA plug-and-receptacle configurations are acceptable for use with DC branch circuits.

Page 19: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Module junction boxes contain and protect the module terminal connections and diodes in the source circuit. Some are field-accessible.

Module junction boxes contain and protect the module terminal connections and diodes in the source circuit. Some are field-accessible.

Page 20: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Multiple PV source circuits are combined into the PV output circuit within the combiner box.

Multiple PV source circuits are combined into the PV output circuit within the combiner box.

Page 21: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Blocking diodes may be used in the source circuit whereas bypass diodes are installed within a module or its junction box. These diodes help preserve system output and protect PV modules from damage.

Blocking diodes may be used in the source circuit whereas bypass diodes are installed within a module or its junction box. These diodes help preserve system output and protect PV modules from damage.

Page 22: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Bypass diodes may be installed in the module junction box.

Bypass diodes may be installed in the module junction box.

Page 23: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

A number of different types of conduit may be used in PV systems if they have the appropriate ratings.

A number of different types of conduit may be used in PV systems if they have the appropriate ratings.

Page 24: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Current-limiting overcurrent protection devices open a short circuit before current reaches its highest value.

Current-limiting overcurrent protection devices open a short circuit before current reaches its highest value.

Page 25: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Overcurrent protection devices include fuses and circuit breakers of various types and ratings.

Overcurrent protection devices include fuses and circuit breakers of various types and ratings.

Page 26: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Array source circuits are fused individually within the source-circuit combiner box.

Array source circuits are fused individually within the source-circuit combiner box.

Page 27: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Overcurrent protection for the inverter output circuit depends on the system type. Overcurrent protection and disconnecting means can be accomplished by using circuit breakers or fused disconnects.

Overcurrent protection for the inverter output circuit depends on the system type. Overcurrent protection and disconnecting means can be accomplished by using circuit breakers or fused disconnects.

Page 28: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Connecting a 120 V inverter to a 120/240 V panelboard with multiwire branch circuits may cause dangerous overloading in the grounded (neutral) branch circuit conductor and must be avoided.

Connecting a 120 V inverter to a 120/240 V panelboard with multiwire branch circuits may cause dangerous overloading in the grounded (neutral) branch circuit conductor and must be avoided.

Page 29: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

The array disconnect opens all current-carrying conductors in the PV output circuit.

The array disconnect opens all current-carrying conductors in the PV output circuit.

Page 30: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

The AC disconnect of an interactive PV system may be located close to the main utility service disconnect, which can satisfy utility requirements for an external, visible-break, and lockable PV system disconnect.

The AC disconnect of an interactive PV system may be located close to the main utility service disconnect, which can satisfy utility requirements for an external, visible-break, and lockable PV system disconnect.

Page 31: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Switches or circuit breakers are required to isolate and disconnect all major components in a PV system from all ungrounded conductors of all power sources.

Switches or circuit breakers are required to isolate and disconnect all major components in a PV system from all ungrounded conductors of all power sources.

Page 32: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

The DC grounding system and the AC grounding system must be connected together with a bonding conductor. The array may also require a separate grounding electrode system.

The DC grounding system and the AC grounding system must be connected together with a bonding conductor. The array may also require a separate grounding electrode system.

Page 33: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Some inverters include fuses as array ground-fault protection in their DC input circuits.Some inverters include fuses as array ground-fault protection in their DC input circuits.

Page 34: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Circuit breakers can be used for array ground-fault protection when the inverter does not already provide this protection.

Circuit breakers can be used for array ground-fault protection when the inverter does not already provide this protection.

Page 35: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

A ground-fault circuit interrupter (GFCI) senses differences between the current in the grounded and ungrounded conductors, indicating a ground fault, and opens the circuit in response.

A ground-fault circuit interrupter (GFCI) senses differences between the current in the grounded and ungrounded conductors, indicating a ground fault, and opens the circuit in response.

Page 36: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Modules should be connected to each other and the mounting structure with grounding conductors to ensure a continuous grounding connection.

Modules should be connected to each other and the mounting structure with grounding conductors to ensure a continuous grounding connection.

Page 37: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Equipment grounding conductors are sized based on the rating of the overcurrent protection device in the circuit.

Equipment grounding conductors are sized based on the rating of the overcurrent protection device in the circuit.

Page 38: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Lightning protection is especially important in the southeastern states, which have the highest lightning-strike density in the United States.

Lightning protection is especially important in the southeastern states, which have the highest lightning-strike density in the United States.

Page 39: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

A lightning protection system includes a network of air terminals, a grounding electrode (down) conductor, and a set of grounding electrodes.

A lightning protection system includes a network of air terminals, a grounding electrode (down) conductor, and a set of grounding electrodes.

Page 40: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Surge arrestors may be incorporated into equipment or can be installed on circuits as separate devices.

Surge arrestors may be incorporated into equipment or can be installed on circuits as separate devices.

Page 41: PowerPoint ® Presentation Chapter 11 Electrical Integration National Electrical Code  Voltage and Current Requirements Conductors and Wiring Methods

Chapter 11 — Electrical IntegrationChapter 11 — Electrical Integration

Connectors may be used for disconnecting high-voltage battery banks into lower voltage segments for servicing.

Connectors may be used for disconnecting high-voltage battery banks into lower voltage segments for servicing.