Possible Spectrometer for eA Collider

Seigo KatoFaculty of Science, Yamagata University,

Yamagata 990-8560, Japan

Presented to the workshop "Rare-Isotope Physics at Storage Rings"

February 3-8, 2002 at Hirschegg, Kleinwalsertal, Austria

Page 2: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

• Requirements• Basic idea• Magnetic field• Expected performances• Size of dipole magnet• Merits and demerits• Spectrometer without the front counter• Conclusion

Contents

Page 3: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

10 cmcolliding length acceptance

6 ominimum angle

10 %momentum range

800 MeV/cmaximum momentum

40 msrsolid angle

1 mrangular resolution

10-4momentum resolution

Requirements to the collider spectrometer

Page 4: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

A double-arm, large acceptance spectrometr “YOKAN”discussed in the collaboration of SMART spectrometer

Page 5: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Possible spectrometers which do not deflect nor stop the beam

1. Conventional spectrometers at the nearest approach to the beam

MAMI-C(6o), JLAB(12o-->6o with septums)

2. Spectrometers in which beams go straight due to special conditions.

2-1 Uniform solenoid field

along the field line ---> B // p

conventional collider spectrometers

2-2 Quadrupole field

along the symmetric axis ---> B = 0

“YOKAN” spectrometer

Page 6: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low
Page 7: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low
Page 8: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Basic idea of the Q-magnet-based spectrometer

• Electron and RI beams collide each other along the symmetry axis of thequadrupole magnet of the spectrometer.

• Intact beams go straight along the field-free, symmetrical axis of thequadrupole magnet.

• Scattered electron are focused vertically, magnifying the acceptance.

• They are horizontally defocused, magnifying the angle of exit.

� Electrons are extracted from the side face of the quadrupole magnet.

Page 9: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

� Electrons scattered to extreme forward angles can be analyzed.

• They are then analyzed by a dipole magnet.

• The exit angle from the quadrupolemagnet is almost constant.

• (demerit) We lose significant part of the information on scattering angles.

• (merit) The scattering angle can be changed without rotating the dipole magnet if we adjust the strength of thequadrupole magnet and/or the colliding position of the beams.

Page 10: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low
Page 11: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Possibilities to change the detection angle

1. Move the dipole magnet parallel to the beam line--- It may be easier than the rotation .

2. Adjust the collision point and Q-magnet strength

3. Adjust only the Q-magnet strength

4. Enlarge the horizontal angular acceptance

Page 12: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

100~300 mr 300~500 mr

Change the detection angle by beam and Q-magnet

Strength of the Q-magnet and the colliding position are adjusted

Page 13: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

20 ~ 100 mr 780 ~ 880 mr

reversed polarity

Extreme forward and extreme backward angles

Page 14: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

100~300 mr 300~500 mr

Change the detection angle only by Q-magnetmerit: fixed collision positiondemerit: reduced horizontal acceptance

Page 15: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

100~500 mr

Cover the necessary angular range with one shot

Page 16: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Counter resolution 0.2 mmMultiple scattering 0.5 mr

Counter resolution 0.1 mmMultiple scattering 0.2 mr

Resolutions

Page 17: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Dependence on the colliding length

Page 18: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Why the colliding length acceptance is so largeIt is because (x|y) is very small at the focal plane (y means the source position along the beam direction).

δy = 50 cm

δθ = 0

δy = 0

δθ = 200 mr

Page 19: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

From traditional to precise expression of fringing field

55

44

33

2210

)exp(11)(

scscscscsccSS

sh

+++++=+

=

Traditional method(J.E.Spencer & H.A.Enge: NIM 49(1967)181)

Define s = x / G and fit By along x-axis by

. 0 if 0

....]!3

[),(

....]!2

)([

.....!2

)0,(),(

2

3

33

0

2

22

0

2

22

==∇

+−=

+−=

+∂

∂+=

jBdx

hdydxdhyByxB

dxhdyxhB

yByxByxB

x

yyy

Extension to two-dimensional space :

Page 20: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Field strength distribution

From the field calculation

From the parameters

up to 2-nd order

We need precise value up to y = G/2.

There is no reason to justify the cut-off at the 2-nd order term.

Can we sum up to infinity?

Page 21: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

From the parameters

exact summation

Occurrence of singularity cannot be avoided.

From the field calculation

Page 22: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

)](Im[),(

)](Re[

)]()Re[exp()()cos(

....]!6!4!2

)([

.....!6!4!2

)0,(),(

0

0

00

6

66

4

44

2

22

0

6

66

4

44

2

22

iyxhByxB

iyxhB

xhx

iyBxhdxdyB

dxhdy

dxhdy

dxhdyxhB

yBy

yBy

yByxByxB

x

yyyyy

+=

+=∂∂==

+−+−=

+∂

∂+

∂∂

+∂

∂+=

Exact summation up to infinity.

If the field is independent of the z-coordinate

There is no reason to terminate the summation at a finite order when the exact summation is possible.

Page 23: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Occurrence of singularities in two-dimensional space

For complex S, exp(S) = -1 is possible.

We have to know the location of singularities by solving following equation:

)12(55

44

33

2210 imscscscscscc π+=+++++

(generally unsolvable)

Gyi

Gxs

scscscscsccSS

sh

+=

+++++=+

=

55

44

33

2210

)exp(11)(

Page 24: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Enge’s long-tail parameter set gives strange field

Up to 2-nd order Up to infinite order

Page 25: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

A new fitting function

Gyi

Gxs +=

location of singularities

n

abssh

)]exp(1[

1)( −+=

,...5 ,3 ,y

aGaGaGbGx

πππ==

16.021 0

≈>

<

πa

b

safety condition

Page 26: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low
Page 27: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Enge’s short tail parameter set gives ….

original parameters parameters converted

Page 28: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

)](Re[),( )](Im[),(

definingby

space full toextended be can fitting The

.

a variable withaxis- along )0,( to

)]exp(1[

])1(1[211

)1()(

fittingby extracted wereParameters

0

0

2

shByxBshByxB

Gyi

Gxs

Gxs

xxBa

bs

dcscsesh

y

x

y

n

==

+=

=

−+

+−−−++=

Field of the quadrupole magnet

Page 29: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low
Page 30: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

standard 20 msr version

Page 31: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

slim 10 msr version

Page 32: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

100~200 mr 200~300 mr

300~400 mr 400~500 mr

Page 33: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Pair spectrometer 1

same polarity

Page 34: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Pair spectrometer 2

opposite polarity

Page 35: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Specification of the magnets

6 T/mfield gradient10 cmgap of dipoles

30 tonmass

280 ~ 540 tonmass24 cmgap

520 ~ 410 kWpower consumption

1.4 Tmaximum field

1.5 Tmaximum field

32 cmgap of quadrupolesquadrupole magnet

dipole magnet

Page 36: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Comparison with existing spectrometers

horizontal planebeam axisvertical planesymmetry

highlowhighmom. resolution

1o?7ominimum angle10~20 msr~ 4πsr5.6 msrsolid angle

existsdo not existexistsfocal planeQDsolenoidDmagnet

10 cm~ 1 m(vertex counter)

5 cm(dipole gap)

colliding lengthacceptance

beambeamfixedtarget presentOPALMAMI-BexampleQ-magnet basedcylindricalconventionaltype

Page 37: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Merits and demerits of the present spectrometer

merits• high resolution• extreme forward angle• large acceptance of   

colliding length• no need of the rotation• existence of focal plane• horizontal median plane• simple structure

demerits • interference with the beam• poor resolution of horizontal

angle• angle dependence of focusing

property• no defining slit

Page 38: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Can we improve the horizontal angular resolution by removing the front counter which causes the serious multiple scattering?

mr 80±<ϕ

mr 200mr 100 <<θ

removal of the front counter

�decrease of momentum resolution

�necessity of dispersion increase

�increase of bending angle

�decrease of horizontal acceptance

�necessity of increasing the vertical angle acceptance

�large gap of quadrupole magnet

Page 39: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Dependence of resolutions on the beam length and on the vertical angle

Page 40: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Required and possible performances

10 ~ 50 cm50 o1 o

10 %800 MeV/c10 ~ 40 msr

1 ~ 4 mr(0.5~1) x 10-4

With front counter

6 o6 ominimum angle

< 10 cm23 o ?

10 %800 MeV/c

12 msr1 mr

1 x 10-4

Without front counter

required

30 omaximum angle

10 %momentum range

10 cmcolliding length acceptance

800 MeV/cmaximum momentum40 msrsolid angle1 mrangular resolution10-4momentum resolution

Page 41: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

ConclusionThe spectrometer equipped with the front counter has many advantages.

- The momentum resolution is enough.

- More than enough angular range can be accepted without rotation.

- More than enough colliding length can be accepted.

- The structure is very simple.

The most serious disadvantage is the poor angular resolution.

It can be improved by removing the front counter and by losing some of the advantages.

The choice depends on the counter development, the beam development, and the requirement of the physics.

Page 42: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Ray-tracing calculation for designing a magnetic spectrometer

2. Trace rays by solving the equation of motion

with appropriate initial conditions.

Bvr ×= qdtdm 2

2

3. Evaluate the optical properties at the counter position.

image sharpness, momentum sensitivity, etc.

1. Prepare magnetic field distribution.

It has to be as realistic as possible.

Page 43: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Field line and field strength distributions of BBS-Q1 magnet

Page 44: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Momentum resolution of a spectrometer

n)(aberratioification)size)(magn (beamdispersion

counterat size image beamcounterat separationresolution

+=

=

aberration elimination: hardware correction vs software correction

Page 45: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

dipole magnet

5704304507402.4

5503804406702.2

4401303503201.0

4601603703701.2

5002403904801.6

4802003804201.4

5202804105401.8

5904804608102.6

5303304206002.0

power (kW)mass (ton)power (kW)mass (ton)

window-frameH-typeuniform field width (m)

B = 1.4 T, L = 2.7 m, G = 25 cm

Page 46: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low

Resolutions of the fat version

Page 47: Possible Spectrometer for eA Collider - · PDF filePossible Spectrometer for eA Collider Seigo Kato ... Adjust the collision point and Q-magnet strength ... mom. resolution high low