270
PNOZmulti error messages Error list1003401EN01 Configurable Control System PNOZmulti

PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

  • Upload
    ngodang

  • View
    236

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

PNOZmulti error messages

Error list­1003401­EN­01

Configurable Control System PNOZmulti

Page 2: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

PrefaceThis document is the original document.

All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be madefor internal purposes. Suggestions and comments for improving this documentation will begratefully received.

Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarksof Pilz GmbH & Co. KG in some countries.

 SD means Secure Digital

Page 3: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Content

Error list PNOZmulti error messages1003401­EN­01

3

Section 1 Introduction 41.1 Displaying the error message on the display 41.2 Evaluate error message 51.2.1 Evaluate error parameters 51.2.2 Example 7

Section 2 Error Messages 9

Section 3 Table for evaluating the error parameters 2673.1 Module I 2673.2 Module II 2673.3 Decentralised modules 2683.4 Inputs and outputs 268

Page 4: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Introduction

Error list PNOZmulti error messages1003401­EN­01

4

1 IntroductionThis description lists all the error messages on the configurable control system PNOZmulti.

This description also explains how to read the error stack on the display of the base unitsPNOZmulti Mini and PNOZmulti 2 and how to evaluate the error parameters.

1.1 Displaying the error message on the displayThe error stack can be read from the PNOZmulti Configurator or shown on the LC display.

Procedure for displaying the error stack on the LC display:

Use the rotary knob on the base unit to display the error stack.

01/64

PA: 00 00 00

00 00

EC: 83 EN: 01

Show

error stack?

X3

X1

X2

X4

T T

M

...CH: A

For details of how to read the error stack using the PNOZmulti Configurator, please refer tothe online help for the PNOZmulti Configurator.

On the display:

Error class (EC): 83

01/64EC: 83PA: 02 31 0001 00

CH: AEN: 18

Error number (EN): 18

Error parameter (P-0): 02

Error parameter (P-1): 31Error parameter (P-4): 00

Error parameter (P-3): 01

Error parameter (P-2): 00

} Line 1: Sequential number of an error stack entry. A new error stack entry is stored in firstplace.

} Line 2:EC: Error classEN: Error number

} Line 3 and 4:PA: Five error parameters (error parameters P­0 ... P­4)

Page 5: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Introduction

Error list PNOZmulti error messages1003401­EN­01

5

INFORMATION

It depends on the error whether or not error parameters are displayed. Theway in which the error parameters should be interpreted also depends onthe error. The error parameters for each error are stated in the chapter en­titled Error messages. The error parameters can be evaluated using thetables in the chapter entitled Tables for evaluating the error parameters(see also the section entitled Evaluate error parameters, in this chapter).

1.2 Evaluate error messageTo evaluate the data on the display, proceed as follows:

} Search under "Error messages" for the error class (EC)

} Search the table for the required error number (EN).

The error message and, if applicable, the error parameters and remedy are displayed in thetable.

1.2.1 Evaluate error parametersThere are error messages and remedies that contain one or more error parameters (P­0 ...P­4).

Any position within the error message that contains an error parameter is identified with anumber, e.g. <1>, <2>....

For each error parameter, the content of the respective error parameter and the way inwhich it is to be interpreted (as I/O no., module no. ...) is displayed under the error messageunder Text Parameter. The data can be read via the number shown on the display (P0 ... P4), with the help of thetables in Chapter 3.Error parameters can have the following content:

} Module no.The error parameter contains the number of a module. The module number can beused to read the corresponding base unit or expansion module in the table ModuleI [  267] or Module II [  267]Example:– On the display

(P­1) = 01

– Text parameter under the error message:

1: Module no. <P­0> (see table "Module I")­> "1st expansion module to the right of the base unit"

} Module no. decentr.The error parameter contains the number of a decentralised module. The module num­ber can be used to read the corresponding decentralised module in the table Decentral­ised modules [  268].

Page 6: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Introduction

Error list PNOZmulti error messages1003401­EN­01

6

Example:– On the display

(P­2) = 01

– Text parameter under the error message:

1: Module no. decentr <P­2> (see table "Decentralised modules")­> "2nd decentralised module on the 1st link module to the left of the base unit"

} I/O no.The error parameter contains the number of an input or output. The I/O number can beused to read the corresponding input or output in the table "Inputs and outputs".Example:– On the display

(P­2) = 01

– Text parameter under the error message:

1: I/O no. <P­2> (see table "Inputs and outputs")­> " Input I1 of base unit"

} Absolute value, decimal or hexadecimalThe error parameter contains an absolute value (. The error parameter can be replaceddirectly by the number on the display.Example:– On the display

(P­2) = 01

– Text parameter under the error message:

1: <P­2> absolute value, decimal­> "1"

} Element in the user programThe error parameter contains the number of an element in the user program. The ele­ment number can be read in the user program in the PNOZmulti Configurator.– On the display

(P­2) = 01

– Text parameter under the error message:

1: Element <P­2> in the user program­> 1st element in the user program

Page 7: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Introduction

Error list PNOZmulti error messages1003401­EN­01

7

1.2.2 Example

On the display:

Error class (EC): 83

01/64EC: 83PA: 02 31 0001 00

CH: AEN: 18

Error number (EN): 18

Error parameter (P-0): 02

Error parameter (P-1): 31Error parameter (P-4): 00

Error parameter (P-3): 01

Error parameter (P-2): 00

Look for the following in the chapter entitled "Error messages":} Error class (EC) 83

} Error number (EN) 18

Errorno.(EN) Error message Remedy

18 Error caused by the feedback loop for theactuator on output <1> (terminal: O<2>Location: <4>Text parameter1: I/O no. <P­1> (see table "Inputs and out­puts")2: <P­3> absolute value, decimal3: Element <P­0> in the user program4: Module no. <P­2> (see table "Module I")

­Ensure that the actuator on output <1> (terminal:O<2>) is operating correctly.­Ensure that the feedback loop on element <3> isconfigured correctly.­Ensure that the feedback loop is wired correctly....

Evaluate the error parameters:} 1: I/O no. <P­1> (see table "Inputs and outputs")

No. on display for P­1: 31Evaluation: I/O no. 31 in table "Inputs and outputs"– <1>: Output O1 of base unit

} 2: <P­3> absolute value, decimalNo. on display for P­3: 01:Content: Absolute value, decimalEvaluation: Value is adopted directly– <2>: 1

} 3: Element <P­0> in the user programNo. on display for P­0: 02Evaluation: Must be evaluated in the assignment list in the PNOZmulti Configurator– <3>: Element 2 in the user program

Page 8: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Introduction

Error list PNOZmulti error messages1003401­EN­01

8

} 4: Module no. <P­2> (see table "Module I")No. on display: 00:Content: Module numberEvaluation: Module no. 00 in table "Module I"– <4>: "Base unit"

Evaluated error message:

Errorno.(EN) Error message Remedy

18 Error caused by the feedback loop for theactuator on output Output O1 of base unit>(terminal: O1Location: Base unit

­Ensure that the actuator on output Output O1(terminal: O1) is operating correctly.­Ensure that the feedback loop on element Ele­ment 2 in the user program is configured cor­rectly.­Ensure that the feedback loop is wired correctly....

Page 9: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

9

2 Error Messages

"Error class" 01No. Error message Remedy

01 Internal error:Location ---

Please contact Pilz.

Page 10: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

10

"Error class" 02No. Error message Remedy

01 Restart was performed.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

02 General reset was performed.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

03 PNOZmulti was stopped by the PNOZmultiConfigurator.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

04 PNOZmulti has accepted the configuration withcheck sum <1><2>.Location <3>Text Parameter1: <P-0> absolute value, hexadecimal2: <P-1> absolute value, hexadecimal3: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

05 Error stack was deleted.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

06 General reset was performed.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

07 General reset was performed.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

08 Error stack was deleted.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

09 General reset was performed.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

Page 11: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

11

"Error class" 81No. Error message Remedy

02 The expansion module installed on position <2>does not correspond to the configuration.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")2: <P-0> absolute value, decimal

Install the expansion module with equipmentID "<1>" on position <2>.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

03 Expansion module is missing.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Install the configured expansion module. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

04 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Ensure that a maximum of 8 expansionmodules are installed.

Please contact Pilz.

05 Too many expansion modules are installed to theright of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

06 Expansion modules are available, although thebase unit does not support expansion modules.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the correct type of base unit isinstalled.

Remove expansion modules. Please contact Pilz.

07 The version of expansion module <2> is notsupported by base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")2: Module No. <P-0> (s. table "Modules I")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

08 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the module. Please contact Pilz.

09 Error on the expansion module "<1>" to the rightof the base unit.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 12: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

12

"Error class" 81No. Error message Remedy

0A A communication module is installed, although itis not configured in the registered hardware.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Check supply voltage Please contact Pilz.

0B The communication module does not correspondto the configuration.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Check supply voltage Please contact Pilz.

0C In the registered hardware a communicationmodule is configured which is not installed.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Check supply voltage Check the type and version of the

communication module. Please contact Pilz.

0F Error on the expansion module "<1>" to the rightof the base unit.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

10 Error on the expansion module "<1>" to the rightof the base unit.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

11 An expansion module has been installed,although it is not configured in the registeredhardware.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Check hardware registry. Please contact Pilz.

12 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the module. Please contact Pilz.

13 Expansion module is missing.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Install the configured expansion module. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

Page 13: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

13

"Error class" 81No. Error message Remedy

14 An expansion module has been installed,although it is not configured in the registeredhardware.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Check hardware registry. Please contact Pilz.

15 The communication module has not beeninstalled in the designated position.Location ---

Check the position of the communicationmodule.

Change the module. Please contact Pilz.

Page 14: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

14

"Error class" 82No. Error message Remedy

01 Chip card containing a new configurationinserted without performing a general reset.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Please contact Pilz.

02 The configuration contains too many elements(e.g. E-STOP).Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the number of elements. Please contact Pilz.

03 No configuration is stored on the chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download the configuration to the chip card. Please contact Pilz.

04 The configuration is too large.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the scope of the configuration. Please contact Pilz.

05 The configuration contains too many elements(e.g. E-STOP).Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the number of elements. Please contact Pilz.

06 The configuration contains too many logicelements.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the number of logic elements. Please contact Pilz.

07 The configuration contains an invalid loopbetween two logic elements (AND, OR, etc.).Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Remove the invalid loop between logicelements (AND, OR etc.).

Please contact Pilz.

08 The version of base unit <1> does not match theconfigured version <2> on the chip card.Location <3>Text Parameter1: <P-0> absolute value, hexadecimal2: <P-1> absolute value, hexadecimal3: Module No. 00 (s. table "Modules I")

Ensure that you install the base unit versionthat is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

12 The version of expansion module <2> is notsupported by base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")2: Module No. <P-1> (s. table "Modules I")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

Page 15: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

15

"Error class" 82No. Error message Remedy

14 The hardware identifier on the base unit <1>does not match the hardware identifier on theunit software <2>.Location <3>Text Parameter1: <P-0> absolute value, hexadecimal2: <P-1> absolute value, hexadecimal3: Module No. 00 (s. table "Modules I")

Clean the unit to remove any potential shortcircuits.

Please contact Pilz.

15 Expansion modules are available, although thebase unit does not support expansion modules.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the correct type of base unit isinstalled.

Remove expansion modules. Please contact Pilz.

16 The configuration contains an element that is notsupported by this version of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Use a version of the base unit thatsupports all the elements available in theconfiguration.

The configuration should only containelements that are supported by this versionof the base unit.

Please contact Pilz.

17 The configuration contains an element that is notsupported by this version of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Use a version of the base unit thatsupports all the elements available in theconfiguration.

The configuration should only containelements that are supported by this versionof the base unit.

Please contact Pilz.

18 The configuration contains an element that is notsupported by this version of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Use a version of the base unit thatsupports all the elements available in theconfiguration.

The configuration should only containelements that are supported by this versionof the base unit.

Please contact Pilz.

1B The configuration is too large.Location Chip card

Reduce the scope of the configuration. Please contact Pilz.

1C The configuration is too large.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the scope of the configuration. Please contact Pilz.

1D No valid configuration is stored on the chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download the configuration to the chip card. Change the chip card. Please contact Pilz.

1E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 16: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

16

"Error class" 82No. Error message Remedy

1F The installed base unit does not correspond tothe configuration.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Install the configured base unit. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

20 Expansion modules are available, although thebase unit does not support expansion modules.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the correct type of base unit isinstalled.

Remove expansion modules. Please contact Pilz.

21 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

22 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

23 The configuration is too large.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the scope of the configuration. Please contact Pilz.

24 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

25 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

26 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

27 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

28 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

29 Too many expansion modules are installed to theright of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

2A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 17: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

17

"Error class" 82No. Error message Remedy

2D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

30 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

31 The base unit version does not match theconfigured version.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the base unit versionthat is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

32 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

33 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

34 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

35 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

36 The configuration includes an integrated linkinterface that is not supported by this base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Install the configured base unit. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

37 Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the same transmission rate isconfigured for the expansion module "<1>"and the expansion module of the oppositeside.

Please contact Pilz.

38 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

39 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 18: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

18

"Error class" 82No. Error message Remedy

3D The configuration contains an element that is notsupported by this version of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Use a version of the base unit thatsupports all the elements available in theconfiguration.

The configuration should only containelements that are supported by this versionof the base unit.

Please contact Pilz.

3E The configuration contains an element that is notsupported by this version of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Use a version of the base unit thatsupports all the elements available in theconfiguration.

The configuration should only containelements that are supported by this versionof the base unit.

Please contact Pilz.

3F The configuration contains an element that is notsupported by this version of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Use a version of the base unit thatsupports all the elements available in theconfiguration.

The configuration should only containelements that are supported by this versionof the base unit.

Please contact Pilz.

40 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

41 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

42 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

43 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

44 The installed base unit does not correspond tothe configuration.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Install the configured base unit. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

45 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

46 Fieldbus modules are available, although thebase unit does not support fieldbus modules.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the correct type of base unit isinstalled.

Remove expansion modules. Please contact Pilz.

Page 19: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

19

"Error class" 82No. Error message Remedy

47 Expansion modules are available, although thebase unit does not support expansion modules.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the correct type of base unit isinstalled.

Remove expansion modules. Please contact Pilz.

Page 20: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

20

"Error class" 83No. Error message Remedy

01 No chip card insertedLocation <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Insert the chip card. Please contact Pilz.

02 Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

03 Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

04 Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

Page 21: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

21

"Error class" 83No. Error message Remedy

0A Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>; I/p. 4 = <4>)Location <5>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: <P-4> absolute value, decimal5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0B Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0C Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0D Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0E Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 22: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

22

"Error class" 83No. Error message Remedy

0F Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

10 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

11 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

12 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

13 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

14 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 23: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

23

"Error class" 83No. Error message Remedy

15 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

16 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

18 Error caused by the feedback loop for theactuator on output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

19 Error caused by the feedback loop for theactuator on output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

Page 24: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

24

"Error class" 83No. Error message Remedy

1A Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

1B Error caused by the feedback loop for theactuator on output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

1C Error caused by the feedback loop for theactuator on output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

1F Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

Page 25: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

25

"Error class" 83No. Error message Remedy

20 Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

21 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

22 Error caused by output "<1>" (terminal: O0)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O0): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

23 Error caused by output "<1>" (terminal: O1)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O1): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

24 Error caused by output "<1>" (terminal: O2)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O2): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

25 Error caused by output "<1>" (terminal: O3)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O3): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

Page 26: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

26

"Error class" 83No. Error message Remedy

26 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

27 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

28 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

29 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 27: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

27

"Error class" 83No. Error message Remedy

33 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

34 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Change the module. Please contact Pilz.

35 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

36 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

37 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 28: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

28

"Error class" 83No. Error message Remedy

38 No valid configuration is stored on the chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download the configuration to the chip card. Change the chip card. Please contact Pilz.

39 No valid configuration is stored on the chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download the configuration to the chip card. Change the chip card. Please contact Pilz.

3A Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

3B Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

3C Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

3D Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

3E Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

3F Error caused by output "<1>" (terminal: O1)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O1): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

40 Error caused by output "<1>" (terminal: O2)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O2): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

Page 29: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

29

"Error class" 83No. Error message Remedy

41 Error caused by output "<1>" (terminal: O3)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O3): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

42 Error caused by output "<1>" (terminal: O0)Location <2>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O0): Ensure thatthere are no short circuits to 0 V or 24 VDCin the wiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

43 Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

44 Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

45 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Insert the chip card. Change the chip card. Change the module. Please contact Pilz.

46 Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

47 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

48 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

Page 30: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

30

"Error class" 83No. Error message Remedy

49 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

4A Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

4B Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

4C There is a 1 signal at more than one input on theoperating mode selector switch "<1>".Location <1>Text Parameter1: Element <P-0> in the user program2:

Operating mode selector switch "<1>":Ensure that there are no short circuits to 24VDC in the wiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

4D Error caused by the feedback loop for theactuator on output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

4E Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

4F Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

50 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

Page 31: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

31

"Error class" 83No. Error message Remedy

51 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

52 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Please contact Pilz.

53 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

54 Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

55 Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

56 Error caused by the feedback loop for theactuator on output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

57 No chip card insertedLocation <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Insert the chip card. Please contact Pilz.

Page 32: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

32

"Error class" 83No. Error message Remedy

58 Error caused by cascading input.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the cascading input is wired inaccordance with the configuration and circuitdiagram. Then reset.

Ensure that there are no short circuits to 24VDC or any other cascade cable in the wiringof the cascading input. Then reset.

Change the cascaded base units one by one. Please contact Pilz.

59 Error caused by cascading input.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the cascading input is wired inaccordance with the configuration and circuitdiagram. Then reset.

Change the cascaded base units one by one. Please contact Pilz.

5A Error caused by cascading input.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the cascading input is wired inaccordance with the configuration and circuitdiagram. Then reset.

Change the cascaded base units one by one. Please contact Pilz.

5B Error caused by cascading output.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the cascading output is wired inaccordance with the configuration and circuitdiagram. Then reset.

Ensure that there are no short circuits to 24VDC or any other cascade cable in the wiringof the cascading output. Then reset.

Change the cascaded base units one by one. Please contact Pilz.

5C Error caused by cascading output.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the cascading output is wired inaccordance with the configuration and circuitdiagram. Then reset.

Ensure that there are no short circuits to 24VDC or any other cascade cable in the wiringof the cascading output. Then reset.

Change the cascaded base units one by one. Please contact Pilz.

5D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

5E Error caused by cascading input.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the cascading input is wired inaccordance with the configuration and circuitdiagram. Then reset.

Change the cascaded base units one by one. Please contact Pilz.

Page 33: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

33

"Error class" 83No. Error message Remedy

5F No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

60 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

61 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

62 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 34: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

34

"Error class" 83No. Error message Remedy

63 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

64 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

65 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

66 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 35: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

35

"Error class" 83No. Error message Remedy

67 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

68 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

75 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

77 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

78 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

79 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

Page 36: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

36

"Error class" 83No. Error message Remedy

7A Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

7B Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

7C Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

7D Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

7E Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

7F Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Output "<1>" (terminal: O<2>): Ensure thereis no open circuit in the wiring of the output.

Change the module. Please contact Pilz.

Page 37: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

37

"Error class" 83No. Error message Remedy

80 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Output "<1>" (terminal: O<2>): Ensure thereis no open circuit in the wiring of the output.

Change the module. Please contact Pilz.

81 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Output "<1>" (terminal: O<2>): Ensure thereis no open circuit in the wiring of the output.

Change the module. Please contact Pilz.

82 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Output "<1>" (terminal: O<2>): Ensure thereis no open circuit in the wiring of the output.

Change the module. Please contact Pilz.

83 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

84 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

85 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

Page 38: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

38

"Error class" 83No. Error message Remedy

86 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

87 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

88 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

89 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

8A Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

8B Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

Page 39: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

39

"Error class" 83No. Error message Remedy

8C Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

8D Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

8E Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Please contact Pilz.

92 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Output "<1>" (terminal: O<2>): Ensure thereis no open circuit in the wiring of the output.

Change the module. Please contact Pilz.

93 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Output "<1>" (terminal: O<2>): Ensure thereis no open circuit in the wiring of the output.

Change the module. Please contact Pilz.

96 Information for the Pilz service department:Location ---

For information only, no remedy required.

97 Information for the Pilz service department:Location ---

For information only, no remedy required.

Page 40: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

40

"Error class" 83No. Error message Remedy

A0 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

A1 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

A2 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

A3 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

A4 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

Page 41: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

41

"Error class" 83No. Error message Remedy

A5 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

A6 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

A7 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

A8 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

A9 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

Page 42: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

42

"Error class" 83No. Error message Remedy

AA The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

AB The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

AC The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

AD The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

B0 Internal error:Location ---

Please contact Pilz.

B1 Internal error:Location ---

Please contact Pilz.

B2 Internal error:Location ---

Please contact Pilz.

Page 43: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

43

"Error class" 83No. Error message Remedy

B3 Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

B4 No valid configuration is stored on the chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download the configuration to the chip card. Change the chip card. Please contact Pilz.

B5 Information for the Pilz service department:Location ---

For information only, no remedy required.

B6 Information for the Pilz service department:Location ---

For information only, no remedy required.

B7 Information for the Pilz service department:Location ---

For information only, no remedy required.

B8 Information for the Pilz service department:Location ---

For information only, no remedy required.

B9 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Insert the chip card. Change the chip card. Change the module. Please contact Pilz.

BA Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

Page 44: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

44

"Error class" 83No. Error message Remedy

BB Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

BC The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

BD Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

BE Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

BF Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C0 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 45: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

45

"Error class" 83No. Error message Remedy

C1 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C2 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C3 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C4 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>)Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C5 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>; I/p. 4 = <4>)Location <5>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: <P-4> absolute value, decimal5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C6 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>; I/p. 4 = <4>)Location <5>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: <P-4> absolute value, decimal5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 46: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

46

"Error class" 83No. Error message Remedy

C7 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>; I/p. 4 = <4>)Location <5>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: <P-4> absolute value, decimal5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C8 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

C9 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

CA Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>)Location <4>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

CB The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 47: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

47

"Error class" 83No. Error message Remedy

CC The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

CD The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

CE The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

CF The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

Page 48: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

48

"Error class" 83No. Error message Remedy

D0 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

D1 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

D2 The input signals from safety mat "<1>" arefaulty.Location <1>Text Parameter1: Element <P-0> in the user program

Safety mat "<1>": Ensure that there are noshort circuits to 0 V or 24 VDC in the wiringof the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Change the module. Please contact Pilz.

D3 Shutdown due to error in step <1> of the burnercycleLocation <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the encoders operate correctly. Please contact Pilz.

D4 Safety chain 1 broken in step <1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the encoders operate correctly. Please contact Pilz.

D5 Safety chain 2 broken in step <1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the encoders operate correctly. Please contact Pilz.

Page 49: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

49

"Error class" 83No. Error message Remedy

D6 Ignition and operation safety chain broken in step<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the encoders operate correctly. Please contact Pilz.

D7 Air pressure error in step <1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the air pressure monitoring

device operates correctly. Ensure that the combustion air supply

operates correctly. Please contact Pilz.

D8 Flame error, main flame in step <1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the air pressure monitoring

device operates correctly. Ensure that the combustion air supply

operates correctly. Ensure that the fuel supply operates

correctly. Ensure that the flame monitoring device

operates correctly. Please contact Pilz.

D9 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

DA Error in step <1> "Compound controller to pre-purge position"Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the compound controller

operates correctly. Please contact Pilz.

DB Error in step <1> "Compound controller toignition position"Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the compound controller

operates correctly. Please contact Pilz.

DC Tightness control error in step <1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the inputs are wired correctly. Ensure that the air pressure monitoring

device operates correctly. Ensure that the safety valves operate

correctly. Please contact Pilz.

Page 50: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

50

"Error class" 83No. Error message Remedy

DD Output "<1>" with advanced fault detection hasbeen shut down incorrectly (feedback loop is notclosed).Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Ensure that the actuator reaction timeis taken into account during power-upmonitoring Ton.

Please contact Pilz.

DE Output "<1>" with advanced fault detection hasbeen shut down incorrectly (feedback loop is notclosed).Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Ensure that the filter time of the feedbackloop input and the actuator reaction timeare taken into account during switch-offmonitoring Toff.

Please contact Pilz.

DF The feedback loop has closed while the actuatorwas switched on.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 51: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

51

"Error class" 83No. Error message Remedy

E0 The output with advanced fault detection hasbeen shut down incorrectly (feedback loop is notclosed).Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Ensure that the actuator reaction timeis taken into account during power-upmonitoring Ton.

Please contact Pilz.

E1 The output with advanced fault detection hasbeen shut down incorrectly (feedback loop is notclosed).Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Ensure that the filter time of the feedbackloop input and the actuator reaction timeare taken into account during switch-offmonitoring Toff.

Please contact Pilz.

E2 The feedback loop has closed while the actuatorwas switched on.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

E3 Error due to base unitLocation <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "A1" and "A2" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

Page 52: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

52

"Error class" 83No. Error message Remedy

E4 Function element was or is partially operated(actual status: I/p. 1 = <1>; I/p. 2 = <2>; I/p. 3 =<3>; I/p. 4 = <4>)Location <5>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: <P-3> absolute value, decimal4: <P-4> absolute value, decimal5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

E5 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

E6 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

E7 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 53: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

53

"Error class" 83No. Error message Remedy

E8 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

E9 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

EA There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

EB No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 54: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

54

"Error class" 83No. Error message Remedy

EC There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

ED No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

EF There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

F0 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

Page 55: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

55

"Error class" 83No. Error message Remedy

F1 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

F2 No input on operating mode selector switch"<1>" has a 1 signal.Location <1>Text Parameter1: Element <P-0> in the user program

Operating mode selector switch "<1>":Ensure that there are no short circuits to 0 Vin the wiring of the inputs.

Operating mode selector switch "<1>":Ensure that there are no open circuits in thewiring of the inputs.

Ensure that the operating mode selectorswitch "<1>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

F3 There is a 1 signal at two inputs on the operatingmode selector switch "<5>".Location <5>Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5: Element <P-4> in the user program

Input i<1> on slot <2>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Input i<3> on slot <4>: Ensure that thereare no short circuits to 24 VDC in the inputwiring.

Ensure that the operating mode selectorswitch "<5>" is wired in accordance with theconfiguration and circuit diagram.

Please contact Pilz.

F4 The inputs that are transmitted via the integratedinterface were set to zero.Location Input

Update inputs within the configuredmonitoring time

Increase monitoring time. Please contact Pilz.

F5 The supply voltage at the base unit is too low.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Check supply voltage Please contact Pilz.

F6 The supply voltage at the base unit is too high.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Check supply voltage Please contact Pilz.

Page 56: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

56

"Error class" 83No. Error message Remedy

F7 Error when switching on the output "<1>" withexpanded error detection (feedback loop noclosed).Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: Module No. <P-0> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

F8 Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there is a connection cablebetween the two PNOZmulti systems.

Ensure that the connection cable meets thespecifications of the PNOZ ml1p operatinginstructions (e.g. pin assignment).

Ensure that the EMC influences on theconnection cable are minimised.

Please contact Pilz.

F9 Error caused by the feedback loop for theactuator on output "<1>" (slot:<3>, terminal:O<2>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: <P-2> absolute value, decimal4: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

FA Error caused by the feedback loop for theactuator on output "<1>" (slot:<3>, terminal:O<2>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: <P-2> absolute value, decimal4: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

Page 57: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

57

"Error class" 83No. Error message Remedy

FB Error caused by the feedback loop for theactuator on output "<1>" (slot:<3>, terminal:O<2>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: <P-2> absolute value, decimal4: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

FC Error caused by the feedback loop for theactuator on output "<1>" (slot:<3>, terminal:O<2>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: <P-2> absolute value, decimal4: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

FD Error caused by the feedback loop for theactuator on output "<1>" (slot:<3>, terminal:O<2>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: <P-2> absolute value, decimal4: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

Page 58: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

58

"Error class" 83No. Error message Remedy

FE Error caused by the feedback loop for theactuator on output "<1>" (slot:<3>, terminal:O<2>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: <P-3> absolute value, decimal3: <P-2> absolute value, decimal4: Module No. <P-2> (s. table "Modules I")

Ensure that the actuator on output"<1>" (terminal: O<2>) is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

FF Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 59: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

59

"Error class" 84No. Error message Remedy

01 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

02 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

03 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

04 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

05 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

06 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

07 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

08 The expansion module version does not matchthe configured version.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

09 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0A Error caused by encoder on axis <1>Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")3:

If possible, increase the standstill frequencyof axis <1> in the configuration.

Ensure that the encoder on axis <1> is wiredcorrectly.

Please contact Pilz.

0B The maximum frequency of the speed monitorhas been exceeded at axis <1>.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")3:

Ensure that the maximum frequency is notexceeded on axis <1>.

Design the encoder wiring and screening sothat EMC influences are minimised.

Change the module. Please contact Pilz.

0C A hysteresis has been configured, although thespeed monitor version does not support this.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")2: <P-1> absolute value, decimal

Speed monitor "<1>", axis <2>: On the "Axisdata" tab, enter 0 % in the "Hysteresis" field.

Use a version of the speed monitor thatsupports hysteresis.

Please contact Pilz.

Page 60: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

60

"Error class" 84No. Error message Remedy

0D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

10 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

11 The incremental encoder is signalling standstilland the proximity switch is signalling movement.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Create a mechanical connection betweenincremental encoder and axis <1>.

Ensure that the incremental encoder is wiredcorrectly.

Please contact Pilz.

12 The incremental encoder is signalling movementand the proximity switch is signalling standstill.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the switching distance of theproximity switch is correct.

Ensure that the proximity switches operatecorrectly.

Ensure that the proximity switch is wiredcorrectly.

Ensure that the proximity switch is wired inaccordance with the configuration and circuitdiagram.

Ensure that supply voltage is applied to theproximity switch.

Dampen position controller of axis <1>. Please contact Pilz.

13 The expansion module version does not matchthe configured version.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

14 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

40 Error driving the speed monitor on axis <2>.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")2: <P-1> absolute value, decimal3: <P-2> absolute value, decimal4: <P-3> absolute value, decimal5:

Speed monitor "<1>", axis <2>: Ensure thatinputs <3> and <4> do not have a 1 signalsimultaneously.

Ensure that the inputs used to select thespeed are wired correctly.

Please contact Pilz.

Page 61: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

61

"Error class" 84No. Error message Remedy

41 Error driving the speed monitor.Location ---Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal

Ensure that inputs <1> and <2> on thespeed monitor do not have a 1 signalsimultaneously.

Ensure that the inputs used to select thespeed are wired correctly.

Please contact Pilz.

42 Internal error:Location ---

Please contact Pilz.

43 The expansion module version does not matchthe configured version.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

44 The expansion module version does not matchthe configured version.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

45 Error driving the speed monitor.Location <3>Text Parameter1: <P-2> absolute value, decimal2: <P-3> absolute value, decimal3: Module No. <P-0> (s. table "Modules I")

Ensure that inputs <1> and <2> on thespeed monitor do not have a 1 signalsimultaneously.

Ensure that the inputs used to select thespeed are wired correctly.

Please contact Pilz.

46 Error driving the speed monitor.Location ---Text Parameter1: <P-0> absolute value, decimal2: <P-1> absolute value, decimal

Ensure that inputs <1> and <2> on thespeed monitor do not have a 1 signalsimultaneously.

Ensure that the inputs used to select thespeed are wired correctly.

Please contact Pilz.

Page 62: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

62

"Error class" 85No. Error message Remedy

01 Communication with the fieldbus is interrupted.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

80 The version of fieldbus module is not supportedby base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the fieldbus moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

81 The version of fieldbus module is not supportedby base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the fieldbus moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

82 A fieldbus module is installed, although it is notconfigured in the registered hardware.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Remove the fieldbus module. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

83 The version of fieldbus module is not supportedby base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the fieldbus moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

84 The fieldbus connection has been restored.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

85 The fieldbus connection has been restored.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

86 The version of fieldbus module is not supportedby base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the fieldbus moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

87 The version of the diagnostic configuration is notsupported by the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Create a version of the diagnosticconfiguration that is supported by the baseunit.

Please contact Pilz.

Page 63: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

63

"Error class" 85No. Error message Remedy

88 The PROFINET module's device name is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Enter a device name for the PROFINETmodule that complies with the specifications(see operating manual for the PROFINETmodule).

Please contact Pilz.

89 The PROFINET module's device name can bedefined by the IO Controller.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

8A The fieldbus module is missing.Location Fieldbus module

Install the configured fieldbus module. Ensure that the links to the fieldbus module

are available. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

8B The fieldbus module is missing.Location Fieldbus module

Install the configured fieldbus module. Ensure that the links to the fieldbus module

are available. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

8C Internal error:Location ---

Please contact Pilz.

8D The fieldbus module is missing.Location Fieldbus module

Install the configured fieldbus module. Ensure that the links to the fieldbus module

are available. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

8E Communication with the fieldbus is interrupted.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

8F The base unit does not support this version ofthe fieldbus module.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the fieldbus moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

Page 64: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

64

"Error class" 86No. Error message Remedy

01 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

02 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

03 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

04 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

05 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

06 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 65: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

65

"Error class" 86No. Error message Remedy

07 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

08 Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there is a connection cablebetween the two PNOZmulti systems.

Ensure that the connection cable meets thespecifications of the PNOZ ml1p operatinginstructions (e.g. pin assignment).

Ensure that the EMC influences on theconnection cable are minimised.

Please contact Pilz.

09 Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there is a connection cablebetween the two PNOZmulti systems.

Ensure that the connection cable meets thespecifications of the PNOZ ml1p operatinginstructions (e.g. pin assignment).

Ensure that the EMC influences on theconnection cable are minimised.

Please contact Pilz.

0A Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the same transmission rate isconfigured for the expansion module "<1>"and the expansion module of the oppositeside.

Please contact Pilz.

0B Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the same transmission rate isconfigured for the expansion module "<1>"and the expansion module of the oppositeside.

Please contact Pilz.

0C Cannot establish a connection between thePNOZmulti systems.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the same transmission rate isconfigured for the expansion module "<1>"and the expansion module of the oppositeside.

Please contact Pilz.

Page 66: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

66

"Error class" 87No. Error message Remedy

01 The value at input I<1> has exceeded the rangelimit R<2>.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Module No. <P-0> (s. table "Modules I")

For information only, no remedy required.

02 The value at input I<1> has fallen below therange limit R<2>.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-2> absolute value, decimal3: Module No. <P-0> (s. table "Modules I")

For information only, no remedy required.

03 Input I<1> is defective.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

04 Tolerance between input I0 and I1 has beenexceeded.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the encoders operate correctly. Ensure that the encoders are wired correctly. Enter a larger tolerance value in the

configuration. Please contact Pilz.

05 The inputs are configured for SIL3 applications,although this version of the analogue inputmodule does not support this.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Analogue input module "<1>": Configure theinputs for SIL2 applications.

Use a version of the analogue input modulethat supports SIL 3 applications.

Please contact Pilz.

06 Voltage inputs have been configured, althoughthis version of the analogue input module doesnot support this.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Use a version of the analogue input modulethat supports voltage inputs.

Please contact Pilz.

07 The current at input I<1> is above the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the current at input I<1> is withinthe permitted signal range (0 ... 25.59 mA).

Please contact Pilz.

Page 67: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

67

"Error class" 87No. Error message Remedy

08 The voltage at input I<1> is above the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the voltage at input I<1> is withinthe permitted signal range (-10.24 ... 10.2375VDC).

Please contact Pilz.

09 The current at input I<1> has reverse polarity.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that input I<1> is wired correctly. Ensure that the current at input I<1> is within

the permitted signal range (0 ... 25.59 mA). Please contact Pilz.

0A The value at input I0 has exceeded the rangelimit R<1>.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

For information only, no remedy required.

0B The value at input I0 has fallen below the rangelimit R<1>.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

For information only, no remedy required.

0C The current at input I<1> is above the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the current at input I<1> is withinthe permitted signal range (0 ... 25.59 mA).

Please contact Pilz.

0D The voltage at input I<1> is above the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the voltage at input I<1> is withinthe permitted signal range (-10.24 ... 10.2375VDC).

Please contact Pilz.

0E The voltage at input I<1> is below the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the voltage at input I<1> is withinthe permitted signal range (-10.24 ... 10.2375VDC).

Please contact Pilz.

0F The voltage at input I<1> is below the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the voltage at input I<1> is withinthe permitted signal range (-10.24 ... 10.2375VDC).

Please contact Pilz.

Page 68: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

68

"Error class" 87No. Error message Remedy

10 The current at input I<1> is below the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the current at input I<1> is withinthe permitted signal range (0 ... 25.59 mA).

Please contact Pilz.

11 The current at input I<1> is below the permittedsignal range.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")

Ensure that the current at input I<1> is withinthe permitted signal range (0 ... 25.59 mA).

Please contact Pilz.

12 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

13 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

14 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

15 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

16 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

17 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

18 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

19 Voltage inputs have been configured, althoughthis version of the analogue input module doesnot support this.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Use a version of the analogue input modulethat supports voltage inputs.

Please contact Pilz.

98 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 69: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

69

"Error class" 89No. Error message Remedy

01 The supply voltage at the link module is too low.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Check supply voltage Please contact Pilz.

02 There are more subscribers connected to the linkmodule than there are configured.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

03 Unknown subscriber at the module "<1>".Location <2>Text Parameter1: Module No. <P-0> (s. table "Modules I")2: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

04 No connection to the decentralised module.Location <1>Text Parameter1: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Ensure that the cabling is error-free. Please contact Pilz.

05 The supply voltage at the link module is too high.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Check supply voltage Please contact Pilz.

06 The decentralised supply voltage at thedecentralised module is too low.Location <1>Text Parameter1: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Check supply voltage at the link module. Check cable cross section and cable run. Reduce load. Please contact Pilz.

07 The supply voltage at the decentralised moduleis too low.Location <1>Text Parameter1: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Check supply voltage at the link module. Check cable cross section and cable run. Reduce load. Please contact Pilz.

08 One or several outputs at the decentralisedmodule are short-circuited.Location <1>Text Parameter1: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Ensure that the wiring is error-free. Check load. Please contact Pilz.

Page 70: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

70

"Error class" 89No. Error message Remedy

09 The temperature at the decentralised module istoo high.Location <1>Text Parameter1: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Reduce load. Reduce ambient temperature. Please contact Pilz.

0A External voltage is applied to one subscriber ofthe link module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the wiring is error-free. Please contact Pilz.

0B Error caused by test pulse input <1> at thedecentralised module.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

0C The connection to the decentralised modules isdisrupted at the link modules.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the cabling is error-free. Rectify source of interference Please contact Pilz.

0D The load on the connection module is too high.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the cabling is error-free. Check load. Please contact Pilz.

10 The installed module does not correspond theconfigured decentralised module.Location <1>Text Parameter1: Exp. I/O no. <P-1> (s. table "Exp. inputs andoutputs")

Install module "<1>" Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

81 Internal error:Location ---

Please contact Pilz.

84 Internal error:Location ---

Please contact Pilz.

85 Internal error:Location ---

Please contact Pilz.

86 Internal error:Location ---

Please contact Pilz.

Page 71: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

71

"Error class" 89No. Error message Remedy

87 Internal error:Location ---

Please contact Pilz.

88 Internal error:Location ---

Please contact Pilz.

89 Internal error:Location ---

Please contact Pilz.

8A Internal error:Location ---

Please contact Pilz.

8B Internal error:Location ---

Please contact Pilz.

8C Internal error:Location ---

Please contact Pilz.

8D Internal error:Location ---

Please contact Pilz.

Page 72: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

72

"Error class" 8ANo. Error message Remedy

01 The base unit version does not match theconfigured version.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the base unit versionthat is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

81 Could not obtain the IP address automatically.Location ---

Make sure that the DHCP Server is active. Deactivate the option: "Obtain IP address

automatically" Please contact Pilz.

82 The IP address of the unit is already use in thenetworkLocation Configuration

Check Ethernet configuration. Please contact Pilz.

83 The inputs that are transmitted via the Ethernetinterface/Modbus were set to zero.Location Input

Update inputs within the configuredmonitoring time

Increase monitoring time. Please contact Pilz.

Page 73: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

73

"Error class" 90No. Error message Remedy

01 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

02 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

03 The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

04 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

05 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 74: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

74

"Error class" 90No. Error message Remedy

06 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

07 The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

08 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

09 <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

0A <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

0B Too many expansion modules are installed to theleft of the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

Page 75: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

75

"Error class" 90No. Error message Remedy

0C Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0D Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0E Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0F Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

10 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

11 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 76: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

76

"Error class" 90No. Error message Remedy

12 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

13 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

14 The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

15 <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

16 Information for the Pilz service department:Location ---

For information only, no remedy required.

17 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 77: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

77

"Error class" 90No. Error message Remedy

18 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

19 <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

1A <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

1B Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

1C <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

1D <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

Page 78: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

78

"Error class" 90No. Error message Remedy

1E Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

1F Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

20 <1> expansion modules are installed to the left ofthe base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

Page 79: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

79

"Error class" 93No. Error message Remedy

01 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

02 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

03 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

Page 80: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

80

"Error class" 93No. Error message Remedy

04 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

05 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

06 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

07 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 81: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

81

"Error class" 93No. Error message Remedy

08 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

09 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0A Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0B Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0C Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>)Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0D Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 82: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

82

"Error class" 93No. Error message Remedy

0E Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

0F Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

10 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

11 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

12 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>)Location <4>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 83: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

83

"Error class" 93No. Error message Remedy

13 Function element was or is partially operated(affected inputs: 1st i/p. = <1>; 2nd i/p. = <2>;3rd i/p. = <3>; 4th i/p. = <4>)Location <5>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: I/O no. <P-2> (s. table "Inputs and outputs")3: I/O no. <P-3> (s. table "Inputs and outputs")4: I/O no. <P-4> (s. table "Inputs and outputs")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

14 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

15 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

16 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

17 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 84: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

84

"Error class" 93No. Error message Remedy

18 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

19 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

1A The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

1B The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

1C The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

1D The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 85: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

85

"Error class" 93No. Error message Remedy

1E The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

1F The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

20 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

21 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

22 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

23 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 86: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

86

"Error class" 93No. Error message Remedy

24 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

25 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

26 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

27 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

28 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

29 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 87: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

87

"Error class" 93No. Error message Remedy

2A Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

2B Error caused by test pulse T<1>Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Test pulse T<1>: Ensure that there are noshort circuits to 24 VDC in the wiring of thetest pulse.

Test pulse T<1>: Ensure that there are noshort circuits to other test pulses in the wiringof the test pulse.

Ensure that test pulse T<1> is wired inaccordance with the configuration and circuitdiagram. To do this, disconnect the inputsone at a time and check whether the errorstill occurs.

Please contact Pilz.

2C Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

2D Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

2E Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

2F Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 88: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

88

"Error class" 93No. Error message Remedy

30 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

31 The input signals from safety mat "<1>" are faulty(affected inputs: 1st i/p. = <2>; 2nd i/p. = <3>).Location <1>Text Parameter1: Element <P-0> in the user program2: I/O no. <P-1> (s. table "Inputs and outputs")3: I/O no. <P-2> (s. table "Inputs and outputs")

Safety mat "<1>": Ensure that there are noshort circuits to 0 V in the wiring of the inputs.

Safety mat "<1>": Ensure that there are noopen circuits in the wiring of the inputs.

Ensure that safety mat "<1>" is wired inaccordance with the configuration and circuitdiagram.

Please contact Pilz.

32 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

33 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

34 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

35 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 89: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

89

"Error class" 93No. Error message Remedy

36 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

37 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

38 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

39 Function element was or is partially operated(affected inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

3A Function element was or is partially operated(affected inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 90: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

90

"Error class" 93No. Error message Remedy

3B Function element was or is partially operated(affected inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

3C Function element was or is partially operated(affected inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

3D Function element was or is partially operated(affected inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

3E Function element was or is partially operated(affected inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 91: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

91

"Error class" 93No. Error message Remedy

3F Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

40 Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

41 Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

42 Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 92: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

92

"Error class" 93No. Error message Remedy

43 Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

44 Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

45 Function element was or is partially operated(potential inputs: 1st i/p. =i<1> module <2> ; 2ndi/p. =i<3> on module <4> or further inputs onelement <5>)Location <5>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")3: <P-4> absolute value, decimal4: Module no. <P-3> (s. table "Modules II")5: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

46 The output with advanced fault detection hasbeen shut down incorrectly (feedback loop is notclosed).Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Ensure that the actuator reaction timeis taken into account during power-upmonitoring Ton.

Please contact Pilz.

Page 93: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

93

"Error class" 93No. Error message Remedy

47 The output with advanced fault detection hasbeen shut down incorrectly (feedback loop is notclosed).Location ---

Ensure that the filter time of the feedbackloop input and the actuator reaction timeare taken into account during switch-offmonitoring Toff.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

48 The feedback loop has closed while the actuatorwas switched on.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Please contact Pilz.

49 Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

4A Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

Page 94: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

94

"Error class" 93No. Error message Remedy

4B Error caused by the feedback loop for theactuator on output <1> of module <2>.Location <2>Text Parameter1: <P-2> absolute value, decimal2: Module no. <P-1> (s. table "Modules II")

Ensure that the actuator on output <1> ofmodule <2> is operating correctly.

Ensure that the feedback loop is configuredcorrectly.

Ensure that the feedback loop is wiredcorrectly.

Ensure that the feedback loop is wired inaccordance with the configuration and circuitdiagram.

Ensure that the feedback loop configurationtakes into account the actual reaction time ofthe actuator.

Please contact Pilz.

4C Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

4D Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

4E Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

4F Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

50 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 95: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

95

"Error class" 93No. Error message Remedy

51 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

52 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

53 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

54 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

55 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

56 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 96: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

96

"Error class" 93No. Error message Remedy

57 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

58 Function element was or is partially operated.Location <1>Text Parameter1: Element <P-0> in the user program

Ensure that the contacts on the input elementoperate correctly.

Ensure that the contacts are wired correctly. Ensure that the input element is wired in

accordance with the configuration and circuitdiagram.

Please contact Pilz.

Page 97: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

97

"Error class" 94No. Error message Remedy

01 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

02 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

03 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

04 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

05 <1> expansion modules are installed to the rightof the base unit, although <2> are configured.Location <3>Text Parameter1: <P-1> absolute value, decimal2: <P-0> absolute value, decimal3: Module No. 00 (s. table "Modules I")

Adapt the actual hardware registry to theconfiguration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

06 The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

Page 98: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

98

"Error class" 94No. Error message Remedy

07 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0A The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

0D The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

Page 99: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

99

"Error class" 95No. Error message Remedy

01 Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

02 Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

03 Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

06 Output defective or no supply voltage to thesemiconductor outputsLocation <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Check the supply voltage of thesemiconductor outputs.

Change the module. Please contact Pilz.

07 Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

08 Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

Page 100: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

100

"Error class" 95No. Error message Remedy

09 Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

0A Error caused by output "<1>" on expansionmodule <2>.Location <3>Text Parameter1: I/O no. <P-1> (s. table "Inputs and outputs")2: Module no. <P-1> (s. table "Modules II")3: Module no. <P-0> (s. table "Modules II")

Output "<1>" on expansion module <2>.Ensure that there are no short circuits to 0 Vor 24 VDC in the output wiring.

Change the module. Please contact Pilz.

0B The temperature on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Reduce ambient temperature. Please contact Pilz.

0C The temperature on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Reduce ambient temperature. Please contact Pilz.

0D The temperature on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Reduce ambient temperature. Please contact Pilz.

0E The temperature on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Reduce ambient temperature. Please contact Pilz.

0F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

10 The version of expansion module <2> is notsupported by base unit <1>.Location <3>Text Parameter1: Module No. 00 (s. table "Modules I")2: Module No. <P-0> (s. table "Modules I")3: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Ensure that you install the base unit versionthat is entered in the configuration.

Please contact Pilz.

Page 101: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

101

"Error class" 95No. Error message Remedy

11 The temperature on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Reduce ambient temperature. Please contact Pilz.

12 The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

13 The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

14 The configuration activates functions of theexpansion module <1> that are not supported bythe base unit 0Y10.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the version of themodules that is entered in the configuration.

Use a version of the base unit thatsupports all the elements available in theconfiguration.

Please contact Pilz.

Page 102: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

102

"Error class" 97No. Error message Remedy

01 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

02 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

03 The signals at Tracks A and /A or B and /B werenot feasible during start-up.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Check supply voltage Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

04 The configured maximum frequency AB hasbeen exceededLocation <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the configured maximumfrequency AB is not exceeded during normaloperation.

Ensure that the connected sensor matchesthe configuration.

Please contact Pilz.

05 The difference in the frequency from Track A andTrack B was too high for too long.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that a frequency difference betweenTrack A and B only occurs during positive/negative acceleration.

Ensure that the proximity switches operatecorrectly.

Please contact Pilz.

06 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

07 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

08 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

09 The difference in the frequency from track ABand track Z was too high for too long.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that a frequency difference betweentrack AB and Z only occurs during positive/negative acceleration.

Ensure that the sensors operate correctly. Please contact Pilz.

0A The signals for the direction of movement werenot feasible.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Remove interference from the sensor

environment. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

0B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 103: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

103

"Error class" 97No. Error message Remedy

0C The configured maximum frequency at track Zhas been exceeded.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the configured maximumfrequency at track Z is not exceeded duringnormal operation.

Ensure that the connected sensor matchesthe configuration.

Please contact Pilz.

0D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

10 The signals for the direction of movement werenot feasible.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Remove interference from the sensor

environment. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

11 Index signal at Track Z came at the wrongposition.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

Page 104: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

104

"Error class" 98No. Error message Remedy

01 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

02 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

03 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

04 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

05 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

06 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

07 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

08 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

09 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

0A Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

Page 105: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

105

"Error class" 98No. Error message Remedy

0B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

10 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

11 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

12 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

13 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

14 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

15 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

16 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

17 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

18 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

19 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

1A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 106: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

106

"Error class" 98No. Error message Remedy

1B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

20 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

21 Program format or program version at device<1> is not supported.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that you install the expansion moduleversion that is entered in the configuration.

Please contact Pilz.

22 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

23 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

24 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

25 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

26 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

27 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

28 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 107: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

107

"Error class" 99No. Error message Remedy

01 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

02 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

03 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

04 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 108: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

108

"Error class" 9ANo. Error message Remedy

01 A "1" signal is always present at Track A or /A.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that there are no short circuits in the

sensor wiring. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

02 A "0" signal is always present at Track A or /A.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that there are no short circuits in the

sensor wiring. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

03 A "1" signal is always present at Track B or /B.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that there are no short circuits in the

sensor wiring. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

04 A "0" signal is always present at Track B or /B.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that there are no short circuits in the

sensor wiring. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

05 The signal at track A has a DC offset.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

06 The signal at Track /A has a DC offset.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

07 The signal at Track B has a DC offset.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

08 The signal at Track /B has a DC offset.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

Page 109: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

109

"Error class" 9ANo. Error message Remedy

09 The signal at Tracks A and B was not feasibleduring operation.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Check supply voltage Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

0A The signals at Tracks A and /A or B and /B werenot feasible.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Remove interference from the sensor

environment. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

0B The index signal at Track Z is missing.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

0C Index signal at Track Z came at the wrongposition.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

0F Signal present at inverted track, although this isnot permitted for the configured sensor type.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

10 Both proximity switches are inactive at the sametime, although this is not permitted.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Install the proximity switch in a way that onlyone proximity switch is active at any time.

Ensure that the proximity switches operatecorrectly.

Check supply voltage Ensure that proximity switches are wired

correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

11 Both proximity switches are inactive at the sametime, although this is not permitted.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Install the proximity switch in a way that onlyone proximity switch is active at any time.

Ensure that the proximity switches operatecorrectly.

Check supply voltage Ensure that proximity switches are wired

correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

Page 110: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

110

"Error class" 9ANo. Error message Remedy

12 Both proximity switches are inactive at the sametime, although this is not permitted.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Install the proximity switch in a way that onlyone proximity switch is active at any time.

Ensure that the proximity switches operatecorrectly.

Check supply voltage Ensure that proximity switches are wired

correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

13 Both proximity switches are inactive at the sametime, although this is not permitted.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Install the proximity switch in a way that onlyone proximity switch is active at any time.

Ensure that the proximity switches operatecorrectly.

Check supply voltage Ensure that proximity switches are wired

correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

14 Signal present at Track /A, although this is notpermitted for the configured sensor type.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

15 Signal present at Track /B, although this is notpermitted for the configured sensor type.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

16 Signal at Track A is outside the valid valueranges for "0" signal and "1" signal.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

17 Signal at Track B is outside the valid valueranges for "0" signal and "1" signal.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors are wired correctly. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

18 Signal at Track S is outside the valid value range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Ensure that the sensors are wired correctly. Ensure that the values configured for Umin

and Umax on Track S suit the application. Ensure that the sensors operate correctly. Please contact Pilz.

Page 111: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

111

"Error class" 9ANo. Error message Remedy

1A A "1" signal is always present at Track Z or /Z.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that there are no short circuits in the

sensor wiring. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

1B A "0" signal is always present at Track Z or /Z.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that there are no short circuits in the

sensor wiring. Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

1C The signals at Tracks A and /A or B and /B werenot feasible during start-up.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Check supply voltage Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

1D The signals at Tracks A and /A or B and /B werenot feasible during start-up.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that the sensors operate correctly. Ensure that the sensors are wired correctly. Check supply voltage Ensure that the correct sensor type is

selected in the configuration. Please contact Pilz.

Page 112: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

112

"Error class" ABNo. Error message Remedy

01 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

02 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

03 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

04 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

05 Internal error:Location ---

Please contact Pilz.

06 Internal error:Location ---

Please contact Pilz.

07 Internal error:Location ---

Please contact Pilz.

Page 113: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

113

"Error class" B0No. Error message Remedy

01 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

02 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

03 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

04 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

07 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

08 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

09 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 114: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

114

"Error class" B0No. Error message Remedy

0C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

10 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

11 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

12 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

13 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

14 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

15 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

16 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 115: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

115

"Error class" B0No. Error message Remedy

17 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

18 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

19 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

20 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

21 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 116: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

116

"Error class" B0No. Error message Remedy

22 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

23 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

24 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

25 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

26 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

27 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

28 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

29 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 117: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

117

"Error class" B0No. Error message Remedy

2D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

30 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

31 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

32 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

33 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

34 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

35 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

36 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

37 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 118: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

118

"Error class" B0No. Error message Remedy

38 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

39 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

3A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

3B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

3C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 119: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

119

"Error class" B1No. Error message Remedy

01 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

02 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

03 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

04 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

07 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 120: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

120

"Error class" B1No. Error message Remedy

10 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

11 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

12 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 121: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

121

"Error class" B2No. Error message Remedy

01 Internal error:Location ---

Please contact Pilz.

02 Internal error:Location ---

Please contact Pilz.

03 Internal error:Location ---

Please contact Pilz.

04 Internal error:Location ---

Please contact Pilz.

05 Internal error:Location ---

Please contact Pilz.

06 Internal error:Location ---

Please contact Pilz.

08 Internal error:Location ---

Please contact Pilz.

09 Internal error:Location ---

Please contact Pilz.

0B Internal error:Location ---

Please contact Pilz.

0C Internal error:Location ---

Please contact Pilz.

0D Internal error:Location ---

Please contact Pilz.

0E Internal error:Location ---

Please contact Pilz.

0F Internal error:Location ---

Please contact Pilz.

10 Internal error:Location ---

Please contact Pilz.

11 Internal error:Location ---

Please contact Pilz.

12 Internal error:Location ---

Please contact Pilz.

14 Internal error:Location ---

Please contact Pilz.

15 Internal error:Location ---

Please contact Pilz.

16 Internal error:Location ---

Please contact Pilz.

Page 122: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

122

"Error class" B2No. Error message Remedy

17 Internal error:Location ---

Please contact Pilz.

18 Internal error:Location ---

Please contact Pilz.

19 Internal error:Location ---

Please contact Pilz.

1A Internal error:Location ---

Please contact Pilz.

1B Internal error:Location ---

Please contact Pilz.

1C Internal error:Location ---

Please contact Pilz.

1D Internal error:Location ---

Please contact Pilz.

1E Internal error:Location ---

Please contact Pilz.

1F Internal error:Location ---

Please contact Pilz.

20 Internal error:Location ---

Please contact Pilz.

21 Internal error:Location ---

Please contact Pilz.

22 Internal error:Location ---

Please contact Pilz.

23 Internal error:Location ---

Please contact Pilz.

24 Internal error:Location ---

Please contact Pilz.

25 Internal error:Location ---

Please contact Pilz.

26 Internal error:Location ---

Please contact Pilz.

27 Internal error:Location ---

Please contact Pilz.

28 Internal error:Location ---

Please contact Pilz.

29 Internal error:Location ---

Please contact Pilz.

Page 123: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

123

"Error class" B2No. Error message Remedy

2A Internal error:Location ---

Please contact Pilz.

2C Internal error:Location ---

Please contact Pilz.

2E Internal error:Location ---

Please contact Pilz.

2F Internal error:Location ---

Please contact Pilz.

30 Internal error:Location ---

Please contact Pilz.

32 Internal error:Location ---

Please contact Pilz.

33 Internal error:Location ---

Please contact Pilz.

34 Internal error:Location ---

Please contact Pilz.

36 Internal error:Location ---

Please contact Pilz.

37 Internal error:Location ---

Please contact Pilz.

38 Internal error:Location ---

Please contact Pilz.

3A Internal error:Location ---

Please contact Pilz.

3B Internal error:Location ---

Please contact Pilz.

3C Internal error:Location ---

Please contact Pilz.

3D Internal error:Location ---

Please contact Pilz.

3E Internal error:Location ---

Please contact Pilz.

3F Internal error:Location ---

Please contact Pilz.

40 Internal error:Location ---

Please contact Pilz.

41 Internal error:Location ---

Please contact Pilz.

Page 124: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

124

"Error class" B2No. Error message Remedy

42 Internal error:Location ---

Please contact Pilz.

44 Internal error:Location ---

Please contact Pilz.

45 Internal error:Location ---

Please contact Pilz.

46 Internal error:Location ---

Please contact Pilz.

47 Information for the Pilz service department:Location ---

For information only, no remedy required.

48 Information for the Pilz service department:Location ---

For information only, no remedy required.

49 Information for the Pilz service department:Location ---

For information only, no remedy required.

4B Internal error:Location ---

Please contact Pilz.

4D Internal error:Location ---

Please contact Pilz.

4E Internal error:Location ---

Please contact Pilz.

4F Internal error:Location ---

Please contact Pilz.

50 Internal error:Location ---

Please contact Pilz.

51 Internal error:Location ---

Please contact Pilz.

52 Internal error:Location ---

Please contact Pilz.

53 Internal error:Location ---

Please contact Pilz.

54 Internal error:Location ---

Please contact Pilz.

55 Internal error:Location ---

Please contact Pilz.

56 Internal error:Location ---

Please contact Pilz.

57 Internal error:Location ---

Please contact Pilz.

Page 125: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

125

"Error class" B2No. Error message Remedy

58 Internal error:Location ---

Please contact Pilz.

59 Internal error:Location ---

Please contact Pilz.

5A Internal error:Location ---

Please contact Pilz.

5B Internal error:Location ---

Please contact Pilz.

5C Internal error:Location ---

Please contact Pilz.

5D Internal error:Location ---

Please contact Pilz.

5E Internal error:Location ---

Please contact Pilz.

5F Internal error:Location ---

Please contact Pilz.

60 Internal error:Location ---

Please contact Pilz.

61 Internal error:Location ---

Please contact Pilz.

62 Internal error:Location ---

Please contact Pilz.

63 Internal error:Location ---

Please contact Pilz.

64 Internal error:Location ---

Please contact Pilz.

65 Internal error:Location ---

Please contact Pilz.

66 Internal error:Location ---

Please contact Pilz.

67 Internal error:Location ---

Please contact Pilz.

6C Internal error:Location ---

Please contact Pilz.

6D Internal error:Location ---

Please contact Pilz.

6E Internal error:Location ---

Please contact Pilz.

Page 126: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

126

"Error class" B2No. Error message Remedy

6F Information for the Pilz service department:Location ---

For information only, no remedy required.

70 Information for the Pilz service department:Location ---

For information only, no remedy required.

71 Internal error:Location ---

Please contact Pilz.

72 Internal error:Location ---

Please contact Pilz.

73 Internal error:Location ---

Please contact Pilz.

74 Internal error:Location ---

Please contact Pilz.

75 Internal error:Location ---

Please contact Pilz.

76 Internal error:Location ---

Please contact Pilz.

77 Internal error:Location ---

Please contact Pilz.

78 Internal error:Location ---

Please contact Pilz.

79 Internal error:Location ---

Please contact Pilz.

7A Internal error:Location ---

Please contact Pilz.

7B Internal error:Location ---

Please contact Pilz.

7C Internal error:Location ---

Please contact Pilz.

7D Internal error:Location ---

Please contact Pilz.

7E Internal error:Location ---

Please contact Pilz.

7F Internal error:Location ---

Please contact Pilz.

80 Internal error:Location ---

Please contact Pilz.

81 Internal error:Location ---

Please contact Pilz.

Page 127: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

127

"Error class" B2No. Error message Remedy

82 Internal error:Location ---

Please contact Pilz.

83 Internal error:Location ---

Please contact Pilz.

84 Internal error:Location ---

Please contact Pilz.

85 Internal error:Location ---

Please contact Pilz.

86 Internal error:Location ---

Please contact Pilz.

87 Internal error:Location ---

Please contact Pilz.

88 Internal error:Location ---

Please contact Pilz.

89 Internal error:Location ---

Please contact Pilz.

8A Internal error:Location ---

Please contact Pilz.

8B Internal error:Location ---

Please contact Pilz.

8C Internal error:Location ---

Please contact Pilz.

8D Internal error:Location ---

Please contact Pilz.

8E Internal error:Location ---

Please contact Pilz.

8F Internal error:Location ---

Please contact Pilz.

90 Internal error:Location ---

Please contact Pilz.

91 Internal error:Location ---

Please contact Pilz.

92 Internal error:Location ---

Please contact Pilz.

93 Internal error:Location ---

Please contact Pilz.

94 Internal error:Location ---

Please contact Pilz.

Page 128: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

128

"Error class" B2No. Error message Remedy

99 Internal error:Location ---

Please contact Pilz.

9A Internal error:Location ---

Please contact Pilz.

9B Internal error:Location ---

Please contact Pilz.

9C Internal error:Location ---

Please contact Pilz.

9D Internal error:Location ---

Please contact Pilz.

9E Internal error:Location ---

Please contact Pilz.

9F Information for the Pilz service department:Location ---

For information only, no remedy required.

A0 Information for the Pilz service department:Location ---

For information only, no remedy required.

A1 Internal error:Location ---

Please contact Pilz.

A2 Internal error:Location ---

Please contact Pilz.

A3 Internal error:Location ---

Please contact Pilz.

A4 Internal error:Location ---

Please contact Pilz.

A5 Internal error:Location ---

Please contact Pilz.

A6 Internal error:Location ---

Please contact Pilz.

A7 Internal error:Location ---

Please contact Pilz.

A8 Internal error:Location ---

Please contact Pilz.

AB Internal error:Location ---

Please contact Pilz.

AC Internal error:Location ---

Please contact Pilz.

AF Internal error:Location ---

Please contact Pilz.

Page 129: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

129

"Error class" B2No. Error message Remedy

B0 Internal error:Location ---

Please contact Pilz.

B1 Internal error:Location ---

Please contact Pilz.

B2 Internal error:Location ---

Please contact Pilz.

B3 Internal error:Location ---

Please contact Pilz.

B4 Internal error:Location ---

Please contact Pilz.

B5 Internal error:Location ---

Please contact Pilz.

B6 Internal error:Location ---

Please contact Pilz.

B7 Internal error:Location ---

Please contact Pilz.

B8 Internal error:Location ---

Please contact Pilz.

B9 Internal error:Location ---

Please contact Pilz.

BA Internal error:Location ---

Please contact Pilz.

BB Internal error:Location ---

Please contact Pilz.

BC Internal error:Location ---

Please contact Pilz.

BD Internal error:Location ---

Please contact Pilz.

BE Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

BF Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

C0 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 130: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

130

"Error class" B2No. Error message Remedy

C1 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

C2 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C3 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C4 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C5 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C6 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C7 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C8 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

C9 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

CA Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

CB Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 131: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

131

"Error class" B2No. Error message Remedy

CC Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

CD Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

CE Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

CF Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D0 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D1 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D2 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D3 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D4 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D5 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D6 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 132: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

132

"Error class" B2No. Error message Remedy

D7 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D8 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

D9 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

DA Internal error:Location ---

Please contact Pilz.

DB Internal error:Location ---

Please contact Pilz.

DC Internal error:Location ---

Please contact Pilz.

DD Internal error:Location ---

Please contact Pilz.

DE Internal error:Location ---

Please contact Pilz.

DF Internal error:Location ---

Please contact Pilz.

E0 Internal error:Location ---

Please contact Pilz.

E1 Internal error:Location ---

Please contact Pilz.

E2 Internal error:Location ---

Please contact Pilz.

E3 Internal error:Location ---

Please contact Pilz.

E4 Internal error:Location ---

Please contact Pilz.

E5 Internal error:Location ---

Please contact Pilz.

E6 Internal error:Location ---

Please contact Pilz.

E7 Internal error:Location ---

Please contact Pilz.

Page 133: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

133

"Error class" B2No. Error message Remedy

E8 Internal error:Location ---

Please contact Pilz.

E9 Internal error:Location ---

Please contact Pilz.

EA Internal error:Location ---

Please contact Pilz.

EB Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

EC Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

ED Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

EE Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

EF Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F0 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F1 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F2 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F3 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F4 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 134: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

134

"Error class" B2No. Error message Remedy

F5 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F6 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F7 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F8 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

F9 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

FA Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

FB Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

FC Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

FD Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

FE Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

FF Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 135: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

135

"Error class" B3No. Error message Remedy

02 Information for the Pilz service department:Location ---

For information only, no remedy required.

04 Information for the Pilz service department:Location ---

For information only, no remedy required.

07 Information for the Pilz service department:Location ---

For information only, no remedy required.

08 Information for the Pilz service department:Location ---

For information only, no remedy required.

09 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

0F Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

10 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

11 Error caused by chip card.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the chip card. Change the module. Please contact Pilz.

12 Information for the Pilz service department:Location ---

For information only, no remedy required.

13 Information for the Pilz service department:Location ---

For information only, no remedy required.

Page 136: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

136

"Error class" B4No. Error message Remedy

01 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

02 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

03 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

04 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

07 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

08 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

09 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 137: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

137

"Error class" B4No. Error message Remedy

0C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

10 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Change the expansion modules one by one

until the error has been rectified. Please contact Pilz.

11 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Change the expansion modules one by one

until the error has been rectified. Please contact Pilz.

12 Terminator is missing.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that there is a terminator to the rightof the last expansion module.

Change the terminator. Change the module. Change the expansion modules one by one

until the error has been rectified. Please contact Pilz.

1B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 138: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

138

"Error class" B4No. Error message Remedy

1D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

20 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

21 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

22 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

23 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

24 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

25 The configuration contains too many elements(e.g. E-STOP).Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the number of elements. Change the module. Please contact Pilz.

26 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

27 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 139: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

139

"Error class" B4No. Error message Remedy

28 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

29 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

30 Information for the Pilz service department:Location ---

For information only, no remedy required.

31 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

32 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 140: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

140

"Error class" B4No. Error message Remedy

33 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

34 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

35 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

36 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

37 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

38 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

39 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3C Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 141: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

141

"Error class" B4No. Error message Remedy

3D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3F Internal error:Location ---

Please contact Pilz.

40 Internal error:Location ---

Please contact Pilz.

Page 142: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

142

"Error class" B5No. Error message Remedy

01 Internal error:Location ---

Please contact Pilz.

02 Internal error:Location ---

Please contact Pilz.

03 Internal error:Location ---

Please contact Pilz.

04 Internal error:Location ---

Please contact Pilz.

05 Internal error:Location ---

Please contact Pilz.

06 Internal error:Location ---

Please contact Pilz.

07 Internal error:Location ---

Please contact Pilz.

08 Internal error:Location ---

Please contact Pilz.

09 Internal error:Location ---

Please contact Pilz.

0A Internal error:Location ---

Please contact Pilz.

0B Internal error:Location ---

Please contact Pilz.

0C Internal error:Location ---

Please contact Pilz.

0D Internal error:Location ---

Please contact Pilz.

0E Internal error:Location ---

Please contact Pilz.

0F Internal error:Location ---

Please contact Pilz.

10 Internal error:Location ---

Please contact Pilz.

11 Internal error:Location ---

Please contact Pilz.

12 Internal error:Location ---

Please contact Pilz.

13 Internal error:Location ---

Please contact Pilz.

Page 143: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

143

"Error class" B5No. Error message Remedy

14 Internal error:Location ---

Please contact Pilz.

15 Internal error:Location ---

Please contact Pilz.

16 Internal error:Location ---

Please contact Pilz.

17 Internal error:Location ---

Please contact Pilz.

18 Internal error:Location ---

Please contact Pilz.

19 Internal error:Location ---

Please contact Pilz.

1A Internal error:Location ---

Please contact Pilz.

1B Internal error:Location ---

Please contact Pilz.

1C Internal error:Location ---

Please contact Pilz.

1D Internal error:Location ---

Please contact Pilz.

1E Internal error:Location ---

Please contact Pilz.

1F Internal error:Location ---

Please contact Pilz.

20 Internal error:Location ---

Please contact Pilz.

21 Internal error:Location ---

Please contact Pilz.

22 Internal error:Location ---

Please contact Pilz.

23 Internal error:Location ---

Please contact Pilz.

24 Internal error:Location ---

Please contact Pilz.

25 Internal error:Location ---

Please contact Pilz.

26 Internal error:Location ---

Please contact Pilz.

Page 144: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

144

"Error class" B5No. Error message Remedy

27 Internal error:Location ---

Please contact Pilz.

28 Internal error:Location ---

Please contact Pilz.

29 Internal error:Location ---

Please contact Pilz.

2A Internal error:Location ---

Please contact Pilz.

30 Internal error:Location ---

Please contact Pilz.

31 Internal error:Location ---

Please contact Pilz.

32 Internal error:Location ---

Please contact Pilz.

33 Internal error:Location ---

Please contact Pilz.

34 Internal error:Location ---

Please contact Pilz.

35 Internal error:Location ---

Please contact Pilz.

36 Internal error:Location ---

Please contact Pilz.

37 Internal error:Location ---

Please contact Pilz.

38 Internal error:Location ---

Please contact Pilz.

39 Internal error:Location ---

Please contact Pilz.

3A Error when detecting shorts between contacts.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the max. cable length on the testpulse output is not exceeded.

Ensure that the max. load on the test pulseoutput is not exceeded.

Please contact Pilz.

3B Internal error:Location ---

Please contact Pilz.

3C Internal error:Location ---

Please contact Pilz.

3D Internal error:Location ---

Please contact Pilz.

Page 145: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

145

"Error class" B5No. Error message Remedy

3E Internal error:Location ---

Please contact Pilz.

3F Internal error:Location ---

Please contact Pilz.

40 Internal error:Location ---

Please contact Pilz.

41 Internal error:Location ---

Please contact Pilz.

42 Internal error:Location ---

Please contact Pilz.

43 Internal error:Location ---

Please contact Pilz.

44 Internal error:Location ---

Please contact Pilz.

45 Internal error:Location ---

Please contact Pilz.

46 Internal error:Location ---

Please contact Pilz.

47 Internal error:Location ---

Please contact Pilz.

48 Internal error:Location ---

Please contact Pilz.

49 Internal error:Location ---

Please contact Pilz.

4A Internal error:Location ---

Please contact Pilz.

4B Internal error:Location ---

Please contact Pilz.

4C Internal error:Location ---

Please contact Pilz.

4D Internal error:Location ---

Please contact Pilz.

4E Internal error:Location ---

Please contact Pilz.

4F Internal error:Location ---

Please contact Pilz.

50 Internal error:Location ---

Please contact Pilz.

Page 146: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

146

"Error class" B5No. Error message Remedy

51 Internal error:Location ---

Please contact Pilz.

52 Internal error:Location ---

Please contact Pilz.

53 Internal error:Location ---

Please contact Pilz.

54 Internal error:Location ---

Please contact Pilz.

55 Internal error:Location ---

Please contact Pilz.

56 Internal error:Location ---

Please contact Pilz.

57 Internal error:Location ---

Please contact Pilz.

58 Internal error:Location ---

Please contact Pilz.

59 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

5A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

5B Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

5C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

5D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

5E Internal error:Location ---

Please contact Pilz.

Page 147: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

147

"Error class" B5No. Error message Remedy

5F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

60 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

61 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

62 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

63 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

64 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

65 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

66 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

67 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

68 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

69 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 148: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

148

"Error class" B5No. Error message Remedy

6A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

6B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

6C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

6D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

6E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

6F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

70 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

71 Internal error:Location ---

Please contact Pilz.

72 Internal error:Location ---

Please contact Pilz.

73 Internal error:Location ---

Please contact Pilz.

74 Internal error:Location ---

Please contact Pilz.

75 Internal error:Location ---

Please contact Pilz.

85 Internal error:Location ---

Please contact Pilz.

86 Internal error:Location ---

Please contact Pilz.

Page 149: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

149

"Error class" B5No. Error message Remedy

87 Internal error:Location ---

Please contact Pilz.

88 Internal error:Location ---

Please contact Pilz.

89 Internal error:Location ---

Please contact Pilz.

8A Internal error:Location ---

Please contact Pilz.

8B Internal error:Location ---

Please contact Pilz.

8C Internal error:Location ---

Please contact Pilz.

Page 150: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

150

"Error class" B6No. Error message Remedy

01 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

02 Internal error:Location ---

Please contact Pilz.

03 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

04 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

05 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

06 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

07 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

08 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

09 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

0A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

0B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 151: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

151

"Error class" B6No. Error message Remedy

0C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

0D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

0E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

0F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

10 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

11 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

12 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

13 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

14 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

15 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

16 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 152: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

152

"Error class" B6No. Error message Remedy

17 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

18 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

19 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

1A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

1B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

1C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

20 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

21 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

22 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

23 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 153: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

153

"Error class" B6No. Error message Remedy

24 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

25 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

26 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

27 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

Page 154: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

154

"Error class" B7No. Error message Remedy

01 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

03 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

04 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

05 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

06 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

07 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

08 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

09 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

10 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

11 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

12 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

13 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

14 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

16 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 155: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

155

"Error class" B7No. Error message Remedy

17 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

18 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

19 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

20 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

21 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

22 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

23 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

24 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

25 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

26 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

27 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

28 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

29 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 156: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

156

"Error class" B7No. Error message Remedy

2A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

30 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

31 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

32 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

33 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

34 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

35 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

36 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

37 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

38 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

39 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 157: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

157

"Error class" B7No. Error message Remedy

3D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

3E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

40 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

41 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

42 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

43 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

44 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

45 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

46 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

47 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

48 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

49 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

4A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

4B The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

4C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

4D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

4E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

4F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 158: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

158

"Error class" B7No. Error message Remedy

50 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

51 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

52 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

53 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

54 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

56 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

57 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

58 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

59 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

5A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

5B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

5C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

5D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

5E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

5F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

60 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

61 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

62 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

63 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 159: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

159

"Error class" B7No. Error message Remedy

64 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

65 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

66 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

67 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

68 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

69 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

6A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

6B The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

6C The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

6E The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

6F The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

70 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

71 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

72 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

Page 160: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

160

"Error class" B7No. Error message Remedy

73 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

74 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

75 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

77 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

78 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

79 The base unit version does not match theconfigured version.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that you install the base unit versionthat is entered in the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

7A The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

7B The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

7C The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

7D The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

Page 161: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

161

"Error class" B7No. Error message Remedy

7E The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

7F The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

80 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

81 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

82 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

83 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

84 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

85 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

86 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

87 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

88 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 162: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

162

"Error class" B7No. Error message Remedy

89 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

8A The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

8B The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

8C The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

8D The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

8E The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

8F The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

90 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

91 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

92 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

93 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

94 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

95 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 163: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

163

"Error class" B7No. Error message Remedy

96 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

97 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

98 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

99 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

9A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

9B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

9C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

9D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

9E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

9F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A0 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A1 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A2 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A3 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A4 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A5 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A6 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A7 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

A8 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 164: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

164

"Error class" B7No. Error message Remedy

A9 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

AA Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

AB Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

AC Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

AD Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

AE Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

AF Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B0 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B1 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B2 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B3 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B4 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B5 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B6 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B7 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B8 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

B9 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

BA Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

BB Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 165: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

165

"Error class" B7No. Error message Remedy

BC Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

BD Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

BE Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

BF Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

C0 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

C1 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

C2 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D0 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D1 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D2 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D3 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D4 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D5 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D6 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D7 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D8 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

D9 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

DA Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 166: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

166

"Error class" B7No. Error message Remedy

DB Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

DC Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

DD Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

DE Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

DF Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E0 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E1 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E2 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E3 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E4 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E5 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E6 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E7 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E8 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

E9 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

EA Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

EB Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

EC Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 167: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

167

"Error class" B7No. Error message Remedy

ED Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

EE Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

EF Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F0 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F1 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F2 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F3 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F4 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F5 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F6 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F7 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F8 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

F9 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

FA Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

FB Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

FC Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

FD Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

FE Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

FF Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 168: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

168

"Error class" B8No. Error message Remedy

01 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

02 Internal error:Location ---

Please contact Pilz.

03 Internal error:Location ---

Please contact Pilz.

04 Internal error:Location ---

Please contact Pilz.

05 Internal error:Location ---

Please contact Pilz.

06 Internal error:Location ---

Please contact Pilz.

07 Internal error:Location ---

Please contact Pilz.

08 Internal error:Location ---

Please contact Pilz.

09 Internal error:Location ---

Please contact Pilz.

0A Internal error:Location ---

Please contact Pilz.

0B Information for the Pilz service department:Location ---

For information only, no remedy required.

0C Internal error:Location ---

Please contact Pilz.

0D Internal error:Location ---

Please contact Pilz.

0E Internal error:Location ---

Please contact Pilz.

0F Internal error:Location ---

Please contact Pilz.

10 Internal error:Location ---

Please contact Pilz.

11 Information for the Pilz service department:Location ---

For information only, no remedy required.

Page 169: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

169

"Error class" B8No. Error message Remedy

12 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

13 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

14 Internal error:Location ---

Please contact Pilz.

15 Internal error:Location ---

Please contact Pilz.

16 Internal error:Location ---

Please contact Pilz.

17 Internal error:Location ---

Please contact Pilz.

18 The configuration contains too many elements(e.g. E-STOP).Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the number of elements. Change the module. Please contact Pilz.

19 Internal error:Location ---

Please contact Pilz.

1A Internal error:Location ---

Please contact Pilz.

1B Internal error:Location ---

Please contact Pilz.

1C Internal error:Location ---

Please contact Pilz.

1D Internal error:Location ---

Please contact Pilz.

1E Internal error:Location ---

Please contact Pilz.

1F Internal error:Location ---

Please contact Pilz.

20 Internal error:Location ---

Please contact Pilz.

21 Internal error:Location ---

Please contact Pilz.

Page 170: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

170

"Error class" B8No. Error message Remedy

24 Internal error:Location ---

Please contact Pilz.

25 Internal error:Location ---

Please contact Pilz.

26 Internal error:Location ---

Please contact Pilz.

27 Internal error:Location ---

Please contact Pilz.

28 Information for the Pilz service department:Location ---

For information only, no remedy required.

29 Information for the Pilz service department:Location ---

For information only, no remedy required.

2A Internal error:Location ---

Please contact Pilz.

2B Internal error:Location ---

Please contact Pilz.

2C The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

2D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2E The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Download the configuration to the chip card. Change the module. Please contact Pilz.

2F Program transfer errorLocation <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Please contact Pilz.

30 Program transfer errorLocation <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Perform a general reset (link from OA0 toI19).

Please contact Pilz.

31 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 171: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

171

"Error class" B8No. Error message Remedy

32 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

33 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

34 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

35 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

36 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

37 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

38 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

39 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 172: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

172

"Error class" B8No. Error message Remedy

3D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

3F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

40 Internal error:Location ---

Please contact Pilz.

41 Internal error:Location ---

Please contact Pilz.

42 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

43 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

44 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

Page 173: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

173

"Error class" B9No. Error message Remedy

01 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

02 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

03 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

04 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

07 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

08 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

09 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 174: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

174

"Error class" B9No. Error message Remedy

0C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

0F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

10 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

11 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

12 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

13 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

15 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

16 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

17 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 175: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

175

"Error class" B9No. Error message Remedy

18 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

19 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1A Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1B Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1C Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1E Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1F Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

20 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

21 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

24 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

Page 176: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

176

"Error class" B9No. Error message Remedy

25 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

26 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

27 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

28 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

29 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

2C Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

2D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

2E Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

2F Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

Page 177: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

177

"Error class" B9No. Error message Remedy

30 Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

31 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

32 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

33 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

34 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

35 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

36 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

37 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

38 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

39 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

3A Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

Page 178: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

178

"Error class" B9No. Error message Remedy

3B Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

3C Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

3D Internal module error.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

3E Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

3F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

40 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Please contact Pilz.

41 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Please contact Pilz.

42 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Please contact Pilz.

43 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Please contact Pilz.

44 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-1> (s. table "Modules I")

Change the module. Please contact Pilz.

45 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 179: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

179

"Error class" B9No. Error message Remedy

46 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

47 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

48 Load current supply is incorrectLocation <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the load current supply is correct. Change the module. Please contact Pilz.

49 Error caused by output "<1>" (terminal: O<2>)Location <3>Text Parameter1: I/O no. <P-0> (s. table "Inputs and outputs")2: <P-2> absolute value, decimal3: Module No. <P-1> (s. table "Modules I")

Output "<1>" (terminal: O<2>): Ensure thereare no short circuits to 0 V or 24 VDC in thewiring of the output.

Change the module. Please contact Pilz.

4A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

4B Load current supply is incorrectLocation <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the load current supply is correct. Change the module. Please contact Pilz.

4C Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

4D Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

4E Load current supply is incorrectLocation <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the load current supply is correct. Change the module. Please contact Pilz.

4F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

Page 180: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

180

"Error class" B9No. Error message Remedy

50 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

51 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

52 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

53 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

54 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

55 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

56 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

57 Internal error:Location ---

Please contact Pilz.

58 Internal error:Location ---

Please contact Pilz.

59 Cannot read the error stack in the base unit <1>.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Ensure that the chip card is insertedcorrectly.

Change the chip card. Please contact Pilz.

Page 181: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

181

"Error class" BANo. Error message Remedy

01 Internal error:Location ---

Please contact Pilz.

02 Internal error:Location ---

Please contact Pilz.

03 Internal error:Location ---

Please contact Pilz.

04 Internal error:Location ---

Please contact Pilz.

05 Internal error:Location ---

Please contact Pilz.

06 Internal error:Location ---

Please contact Pilz.

07 Internal error:Location ---

Please contact Pilz.

08 Internal error:Location ---

Please contact Pilz.

09 Internal error:Location ---

Please contact Pilz.

0A Internal error:Location ---

Please contact Pilz.

0B Internal error:Location ---

Please contact Pilz.

0C Internal error:Location ---

Please contact Pilz.

0D Internal error:Location ---

Please contact Pilz.

0E Internal error:Location ---

Please contact Pilz.

0F Internal error:Location ---

Please contact Pilz.

10 Internal error:Location ---

Please contact Pilz.

11 Internal error:Location ---

Please contact Pilz.

12 Internal error:Location ---

Please contact Pilz.

13 Internal error:Location ---

Please contact Pilz.

Page 182: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

182

"Error class" BANo. Error message Remedy

14 Internal error:Location ---

Please contact Pilz.

15 Internal error:Location ---

Please contact Pilz.

16 Internal error:Location ---

Please contact Pilz.

17 Internal error:Location ---

Please contact Pilz.

18 Internal error:Location ---

Please contact Pilz.

19 Internal error:Location ---

Please contact Pilz.

1A Internal error:Location ---

Please contact Pilz.

1B Internal error:Location ---

Please contact Pilz.

1C Internal error:Location ---

Please contact Pilz.

1D Internal error:Location ---

Please contact Pilz.

1E Internal error:Location ---

Please contact Pilz.

1F Internal error:Location ---

Please contact Pilz.

20 Information for the Pilz service department:Location ---

For information only, no remedy required.

21 Internal error:Location ---

Please contact Pilz.

22 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

23 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

24 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 183: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

183

"Error class" BANo. Error message Remedy

25 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

26 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

27 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

28 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

29 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

2A Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

2B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

40 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

41 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

80 The fieldbus module is missing.Location Fieldbus module

Install the configured fieldbus module. Ensure that the links to the fieldbus module

are available. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Check hardware registry. Please contact Pilz.

Page 184: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

184

"Error class" BANo. Error message Remedy

81 Internal error:Location ---

Please contact Pilz.

82 Internal error:Location ---

Please contact Pilz.

83 Internal error:Location ---

Please contact Pilz.

84 Internal error:Location ---

Please contact Pilz.

85 Internal error:Location ---

Please contact Pilz.

86 Internal error:Location ---

Please contact Pilz.

87 Internal error:Location ---

Please contact Pilz.

88 Internal error:Location ---

Please contact Pilz.

89 Internal error:Location ---

Please contact Pilz.

8A Internal error:Location ---

Please contact Pilz.

8B Internal error:Location ---

Please contact Pilz.

8C Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

8D Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

8E Internal error:Location ---

Please contact Pilz.

8F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

90 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 185: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

185

"Error class" BANo. Error message Remedy

91 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

92 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

93 Internal error:Location ---

Please contact Pilz.

94 Internal fieldbus module error.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 186: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

186

"Error class" BBNo. Error message Remedy

01 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

03 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 187: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

187

"Error class" BBNo. Error message Remedy

0C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

10 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

11 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

12 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

13 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

16 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 188: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

188

"Error class" BBNo. Error message Remedy

17 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

18 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

20 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

21 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 189: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

189

"Error class" BBNo. Error message Remedy

22 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

23 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

24 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

25 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

26 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

27 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

28 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

29 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 190: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

190

"Error class" BBNo. Error message Remedy

2D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

30 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

31 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

32 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

33 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

34 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

35 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

36 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

37 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 191: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

191

"Error class" BBNo. Error message Remedy

38 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

39 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

40 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

41 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

42 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 192: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

192

"Error class" BBNo. Error message Remedy

43 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

44 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

45 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

46 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

47 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

48 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

49 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 193: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

193

"Error class" BBNo. Error message Remedy

4E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

50 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

51 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

52 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

53 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

54 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

55 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

56 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

57 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

58 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 194: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

194

"Error class" BBNo. Error message Remedy

59 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

60 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

61 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

62 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

63 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 195: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

195

"Error class" BBNo. Error message Remedy

64 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

65 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

66 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

67 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

68 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

69 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

6A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 196: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

196

"Error class" BBNo. Error message Remedy

6D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

6E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

6F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

70 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

71 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

72 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

73 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

74 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

75 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 197: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

197

"Error class" BBNo. Error message Remedy

76 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

77 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

78 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

79 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 198: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

198

"Error class" BCNo. Error message Remedy

01 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

02 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

03 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

07 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

08 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

09 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0A Expansion module was stopped via the baseunit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

For information only, no remedy required.

0B Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 199: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

199

"Error class" BCNo. Error message Remedy

0C Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0E Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0F Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

10 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

11 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

12 The expansion module is being disturbed byEMC influencesLocation <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Design the encoder wiring and screening sothat EMC influences are minimised.

Please contact Pilz.

13 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

16 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 200: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

200

"Error class" BCNo. Error message Remedy

17 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

18 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1C Error caused by encoder on axis <1>Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module No. <P-0> (s. table "Modules I")3:

If possible, increase the standstill frequencyof axis <1> in the configuration.

Ensure that the encoder on axis <1> is wiredcorrectly.

Please contact Pilz.

1D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1E Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

20 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 201: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

201

"Error class" BCNo. Error message Remedy

21 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

40 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

41 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

42 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

43 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

44 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

46 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

47 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

48 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

49 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 202: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

202

"Error class" BCNo. Error message Remedy

4A Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4B Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4C Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4E Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4F Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

50 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

51 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

52 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

53 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

54 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 203: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

203

"Error class" BCNo. Error message Remedy

55 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

56 Internal error:Location ---

Please contact Pilz.

57 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

58 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

59 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5A Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5B Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5C Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5E Internal error:Location ---

Please contact Pilz.

5F Internal error:Location ---

Please contact Pilz.

60 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 204: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

204

"Error class" BCNo. Error message Remedy

61 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 205: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

205

"Error class" BDNo. Error message Remedy

01 Internal error:Location ---

Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

03 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

06 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 206: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

206

"Error class" BDNo. Error message Remedy

0C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

0F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

10 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

11 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

12 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

13 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

16 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 207: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

207

"Error class" BDNo. Error message Remedy

17 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

18 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

1D Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

1E Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

1F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

20 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 208: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

208

"Error class" BDNo. Error message Remedy

21 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

22 Error caused by module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

23 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

24 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

25 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

26 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

27 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

28 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

29 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 209: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

209

"Error class" BDNo. Error message Remedy

2B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

2F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

30 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

31 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

32 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

33 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

34 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

35 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 210: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

210

"Error class" BDNo. Error message Remedy

36 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

37 Internal error:Location ---

Please contact Pilz.

38 Internal error:Location ---

Please contact Pilz.

39 Internal error:Location ---

Please contact Pilz.

3A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

3F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

40 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

41 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 211: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

211

"Error class" BDNo. Error message Remedy

42 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

43 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

44 Internal error:Location ---

Please contact Pilz.

45 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

46 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

47 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

48 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

49 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 212: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

212

"Error class" BDNo. Error message Remedy

4D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

4F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

50 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

51 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

52 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

53 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

54 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

55 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

56 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

57 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 213: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

213

"Error class" BDNo. Error message Remedy

58 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

59 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

5F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

60 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

61 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

62 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 214: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

214

"Error class" BDNo. Error message Remedy

63 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

64 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

65 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

66 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

67 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

68 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

69 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 215: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

215

"Error class" BDNo. Error message Remedy

6E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

6F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

70 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

71 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

72 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

73 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

74 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

75 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

76 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

77 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

78 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 216: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

216

"Error class" BDNo. Error message Remedy

79 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

7F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

80 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

81 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

82 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

83 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 217: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

217

"Error class" BDNo. Error message Remedy

84 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

85 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

86 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

87 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

88 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

89 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

8A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

8B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

8C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

8D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

8E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 218: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

218

"Error class" BDNo. Error message Remedy

8F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

90 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

91 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

92 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

93 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

94 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

95 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

96 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

97 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

98 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

99 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 219: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

219

"Error class" BDNo. Error message Remedy

9A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

9B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

9C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

9D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

9E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

9F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A0 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A1 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A2 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A3 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A4 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

Page 220: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

220

"Error class" BDNo. Error message Remedy

A5 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A6 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A7 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A8 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

A9 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

AA Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

AB Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 221: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

221

"Error class" BENo. Error message Remedy

01 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

03 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

0E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 222: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

222

"Error class" BENo. Error message Remedy

0F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

10 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

11 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

12 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

13 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

16 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

17 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

18 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 223: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

223

"Error class" BENo. Error message Remedy

1A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

20 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

21 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

22 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

23 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

24 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 224: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

224

"Error class" BENo. Error message Remedy

25 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

26 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

27 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

28 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

29 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

2A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

2B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

2C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

2D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

2E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

2F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 225: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

225

"Error class" BENo. Error message Remedy

31 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

32 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

33 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

34 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

35 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

36 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

37 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

38 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

39 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 226: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

226

"Error class" BENo. Error message Remedy

3C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

40 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

41 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

42 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

43 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

44 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

45 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

46 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 227: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

227

"Error class" BENo. Error message Remedy

47 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

48 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

49 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

4F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

50 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

51 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 228: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

228

"Error class" BENo. Error message Remedy

52 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

53 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

54 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

55 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

56 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

58 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

59 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5D Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 229: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

229

"Error class" BENo. Error message Remedy

5E Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

5F Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

60 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

61 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

62 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

63 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

64 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

65 The connection to the decentralised modules isdisrupted at the link modules.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the cabling is error-free. Rectify source of interference Please contact Pilz.

66 The connection to the decentralised modules isdisrupted at the link modules.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the cabling is error-free. Rectify source of interference Please contact Pilz.

67 The connection to the decentralised modules isdisrupted at the link modules.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that the cabling is error-free. Rectify source of interference Please contact Pilz.

Page 230: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

230

"Error class" BENo. Error message Remedy

68 Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 231: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

231

"Error class" BFNo. Error message Remedy

01 Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

02 Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

03 Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

04 Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Please contact Pilz.

06 Information for the Pilz service department:Location ---

For information only, no remedy required.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

09 Internal error:Location ---

Please contact Pilz.

0A Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

36 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

37 Internal error of the decentralised module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

Page 232: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

232

"Error class" BFNo. Error message Remedy

38 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

39 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3A Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3B Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

3C Internal error:Location ---

Please contact Pilz.

81 Internal error:Location ---

Please contact Pilz.

8A Internal error:Location ---

Please contact Pilz.

Page 233: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

233

"Error class" C0No. Error message Remedy

02 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

03 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

04 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

05 Internal error:Location ---

Please contact Pilz.

06 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

07 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 234: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

234

"Error class" C0No. Error message Remedy

09 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0C The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

0D The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

0E The expansion module on position -<1> does notmatch the configuration.Location <2>Text Parameter1: <P-0> absolute value, decimal2: Module No. 00 (s. table "Modules I")

Ensure that the expansion module installedon position -<1> is the module that is enteredin the configuration.

Ensure that the configuration downloaded tothe PNOZmulti is the one that was intendedfor this unit.

Position -<1>: Ensure an interruption-freesupply of 24 VDC at the "0 V" and "24 V"terminals.

Please contact Pilz.

0F Internal error:Location ---

Please contact Pilz.

10 Internal error:Location ---

Please contact Pilz.

Page 235: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

235

"Error class" C0No. Error message Remedy

11 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

12 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

13 Internal error:Location ---

Please contact Pilz.

14 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

15 Internal error:Location ---

Please contact Pilz.

16 Internal error:Location ---

Please contact Pilz.

17 Internal error:Location ---

Please contact Pilz.

18 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

19 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Change the module. Please contact Pilz.

1A Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

Page 236: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

236

"Error class" C0No. Error message Remedy

1B Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

1D Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1E Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

1F Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

20 Information for the Pilz service department:Location ---

For information only, no remedy required.

21 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

22 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 237: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

237

"Error class" C1No. Error message Remedy

01 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

02 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

03 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

04 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

05 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

06 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

07 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

08 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

09 Internal module error.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Change the module. Change the module. Please contact Pilz.

0A Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 238: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

238

"Error class" C1No. Error message Remedy

0B Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0C Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0D Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the left-hand sideof the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 239: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

239

"Error class" C2No. Error message Remedy

01 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

02 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

03 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

81 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

82 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

83 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

84 The Ethernet connection has been restarted aftera fault.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the number of connections. Reduce ETH traffic. Please contact Pilz.

85 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

86 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

87 Internal error:Location ---

Please contact Pilz.

88 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

89 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

Page 240: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

240

"Error class" C2No. Error message Remedy

8A Information for the Pilz service department:Location ---

For information only, no remedy required.

Page 241: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

241

"Error class" C3No. Error message Remedy

01 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

02 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

03 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

04 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

05 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

06 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

07 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

08 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

09 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0F Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

10 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

11 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

12 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

Page 242: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

242

"Error class" C3No. Error message Remedy

13 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

14 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

15 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

16 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

17 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

18 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

19 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

20 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

21 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

22 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 243: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

243

"Error class" C3No. Error message Remedy

23 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

24 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

25 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

26 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

27 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

28 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

29 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2A Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2B Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2C Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2D The configuration is too large.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Reduce the scope of the configuration. Please contact Pilz.

Page 244: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

244

"Error class" C4No. Error message Remedy

01 Internal error:Location ---

Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

03 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

06 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0A Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 245: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

245

"Error class" C4No. Error message Remedy

0B Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0D Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0E Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

0F Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

10 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

Page 246: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

246

"Error class" C4No. Error message Remedy

11 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

12 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

13 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

14 The installed base unit does not correspond tothe configuration.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Install the configured base unit. Ensure that the configuration downloaded to

the PNOZmulti is the one that was intendedfor this unit.

Please contact Pilz.

15 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

16 The configuration is invalid.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Download configuration to the PNOZmultiagain.

Please contact Pilz.

Page 247: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

247

"Error class" C4No. Error message Remedy

17 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

18 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

19 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

1A Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

1B Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

1D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

1E Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

Page 248: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

248

"Error class" C4No. Error message Remedy

1F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

20 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

21 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

22 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

23 Communication between the base unit andexpansion module has been interrupted.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Change the module. Change the module. Please contact Pilz.

24 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 249: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

249

"Error class" C5No. Error message Remedy

01 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

03 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

05 Input I<1> is defective.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

0B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

0C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

Page 250: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

250

"Error class" C5No. Error message Remedy

0D Error caused by module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

10 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

11 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

12 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

16 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

17 Internal error on the expansion module.Location <1>Text Parameter1: Module No. <P-0> (s. table "Modules I")

Please contact Pilz.

18 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 251: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

251

"Error class" C5No. Error message Remedy

1A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

1D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1E Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

1F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

20 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

21 Error caused by module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure an interruption-free supply of 24 VDCat the "0 V" and "24 V" terminals.

Ensure that there are no short circuits to 0 Vor 24 VDC in the wiring of the supply voltage.

Change the module. Please contact Pilz.

22 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

23 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

Page 252: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

252

"Error class" C5No. Error message Remedy

24 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

25 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

26 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

27 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

28 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

29 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

2A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

2B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

2C Input I<1> is defective.Location <2>Text Parameter1: <P-1> absolute value, decimal2: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

2D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

2E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

2F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 253: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

253

"Error class" C5No. Error message Remedy

30 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

31 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

32 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

33 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

34 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

35 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

36 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

37 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

38 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

39 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

3A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 254: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

254

"Error class" C5No. Error message Remedy

3B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

3C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

3D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

3E Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

3F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

40 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

41 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

42 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

43 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

44 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

45 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

Page 255: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

255

"Error class" C5No. Error message Remedy

46 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

47 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

48 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

49 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

4A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

4B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

4C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

4D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

4E Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

4F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

50 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

Page 256: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

256

"Error class" C5No. Error message Remedy

51 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

52 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

53 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

54 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

55 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

56 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

57 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

58 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

59 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

5A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Change the module. Please contact Pilz.

5B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 257: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

257

"Error class" C5No. Error message Remedy

5C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

5D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

5E Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

5F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

60 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

61 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

62 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

63 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

64 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

65 Internal error:Location ---

Please contact Pilz.

66 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 258: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

258

"Error class" C5No. Error message Remedy

67 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

68 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

69 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

6A The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

6B The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

6C The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

6D The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

6E The supply voltage on the expansion module isoutside the valid range.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Check supply voltage Please contact Pilz.

6F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 259: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

259

"Error class" C7No. Error message Remedy

01 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

03 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

04 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

06 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

08 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 260: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

260

"Error class" C7No. Error message Remedy

0D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

0F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

10 The configuration at device <1> has not beenadopted in full.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Perform a general reset (link from OA0 toI19).

Download configuration to the PNOZmultiagain.

Please contact Pilz.

11 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

12 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

13 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

16 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

17 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 261: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

261

"Error class" C7No. Error message Remedy

18 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1C Information for the Pilz service department:Location ---

For information only, no remedy required.

1D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1F Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 262: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

262

"Error class" C8No. Error message Remedy

01 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

02 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

03 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

04 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

05 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

06 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

07 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

08 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

09 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

Page 263: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

263

"Error class" C8No. Error message Remedy

0C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0D Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0E Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

0F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

10 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

11 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

12 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

13 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

14 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

15 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

16 Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

Page 264: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

264

"Error class" C8No. Error message Remedy

17 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

18 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

19 Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1A Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1B Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1C Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

1D Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1E Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

1F Internal error on the expansion module.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Please contact Pilz.

20 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

21 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

22 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

23 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

24 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

Page 265: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

265

"Error class" C9No. Error message Remedy

01 Internal error on the PNOZmulti Configurator.Location Configuration

Please contact Pilz.

02 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

03 Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

04 Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

05 Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

06 Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

07 Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

08 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

09 Internal error on the base unit.Location <1>Text Parameter1: Module No. 00 (s. table "Modules I")

Please contact Pilz.

0A Error in communication between the base unitand expansion module <1>.Location <1>Text Parameter1: Module no. <P-0> (s. table "Modules II")

Ensure that there are jumpers between allthe expansion modules on the right-handside of the base unit.

Please contact Pilz.

Page 266: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Error Messages

Error list PNOZmulti error messages1003401­EN­01

266

"Error class" FENo. Error message Remedy

01 Information for the Pilz service department:Location ---

For information only, no remedy required.

02 Information for the Pilz service department:Location ---

For information only, no remedy required.

Page 267: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Table for evaluating the error parameters

Error list PNOZmulti error messages1003401­EN­01

267

3 Table for evaluating the error parameters

3.1 Module IModule no. Module

00 Base unit

01 1st expansion module to the right of the base unit

02 2nd expansion module to the right of the base unit

03 3rd expansion module to the right of the base unit

04 4th expansion module to the right of the base unit

05 5th expansion module to the right of the base unit

06 6th expansion module to the right of the base unit

07 7th expansion module to the right of the base unit

08 8th expansion module to the right of the base unit

09 Fieldbus module

0A 1st expansion module to the left of the base unit

0B 2nd expansion module to the left of the base unit

0C 3rd expansion module to the left of the base unit

0D 4th expansion module to the left of the base unit

0E 5th expansion module to the left of the base unit

0F 6th expansion module to the left of the base unit

F1 Integrated interface to connect 2 base units

3.2 Module IIModule no. Module

01 1st expansion module to the left of the base unit

02 2nd expansion module to the left of the base unit

03 3rd expansion module to the left of the base unit

04 4th expansion module to the left of the base unit

05 5th expansion module to the left of the base unit

06 6th expansion module to the left of the base unit

20 1st expansion module to the right of the base unit

21 2nd expansion module to the right of the base unit

22 3rd expansion module to the right of the base unit

23 4th expansion module to the right of the base unit

24 5th expansion module to the right of the base unit

25 6th expansion module to the right of the base unit

26 7th expansion module to the right of the base unit

Page 268: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Table for evaluating the error parameters

Error list PNOZmulti error messages1003401­EN­01

268

Module no. Module

27 8th expansion module to the right of the base unit

E0 Fieldbus module

F0 Base unit

F1 Integrated interface to connect 2 base units

F2 Safe Ethernet connection

3.3 Decentralised modulesModule no. Module

00 1st decentralised module on the 1st link module to the left of the base unit

01 2nd decentralised module on the 1st link module to the left of the base unit

02 3rd decentralised module on the 1st link module to the left of the base unit

03 4th decentralised module on the 1st link module to the left of the base unit

10 1st decentralised module on the 2nd link module to the left of the base unit

11 2nd decentralised module on the 2nd link module to the left of the base unit

12 3rd decentralised module on the 2nd link module to the left of the base unit

13 4th decentralised module on the 2nd link module to the left of the base unit

20 1st decentralised module on the 3rd link module to the left of the base unit

21 2nd decentralised module on the 3rd link module to the left of the base unit

22 3rd decentralised module on the 3rd link module to the left of the base unit

23 4th decentralised module on the 3rd link module to the left of the base unit

30 1st decentralised module on the 4th link module to the left of the base unit

31 2nd decentralised module on the 4th link module to the left of the base unit

32 3rd decentralised module on the 4th link module to the left of the base unit

33 4th decentralised module on the 4th link module to the left of the base unit

3.4 Inputs and outputsI/O no. Input/output

00 Input I0 of base unit

01 Input I1 of base unit

02 Input I2 of base unit

03 Input I3 of base unit

04 Input I4 of base unit

05 Input I5 of base unit

06 Input I6 of base unit

07 Input I7 of base unit

... ...

Page 269: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

Table for evaluating the error parameters

Error list PNOZmulti error messages1003401­EN­01

269

I/O no. Input/output

23 Input I19 of base unit

30 Output O0 of base unit

31 Output O1 of base unit

32 Output O2 of base unit

33 Output O3 of base unit

40 Output O4 of base unit

41 Output O5 of base unit

50 Input/output I/O 0 of the 1st expansion module to the right of the base unit

51 Input/output I/O 1 of the 1st expansion module to the right of the base unit

52 Input/output I/O 2 of the 1st expansion module to the right of the base unit

... ...

60 Input/output I/O 0 of the 2nd expansion module to the right of the base unit

61 Input/output I/O 1 of the 2nd expansion module to the right of the base unit

... ...

71 Input/output I/O 0 of the 3rd expansion module to the right of the base unit

72 Input/output I/O 1 of the 3rd expansion module to the right of the base unit

... ...

Page 270: PNOZmulti error messages - Home - Systemotronic · 2017-12-11 · Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS ... Error list PNOZmulti error messages 1003401EN01 7

The Best of German En gineering

Partner of:

SupportTechnical support is available from Pilz round the clock.

Americas

Brazil

+55 11 97569-2804

Canada

+1 888-315-PILZ (315-7459)

Mexico

+52 55 5572 1300

USA (toll-free)

+1 877-PILZUSA (745-9872)

Asia

China

+86 21 60880878-216

Japan

+81 45 471-2281

South Korea

+82 31 450 0680

Australia

+61 3 95446300

Europe

Austria

+43 1 7986263-0

Belgium, Luxembourg

+32 9 3217575

France

+33 3 88104000

Germany

+49 711 3409-444

Ireland

+353 21 4804983

Italy

+39 0362 1826711

Scandinavia

+45 74436332

Spain

+34 938497433

Switzerland

+41 62 88979-30

The Netherlands

+31 347 320477

Turkey

+90 216 5775552

United Kingdom

+44 1536 462203

You can reach our

international hotline on:

+49 711 3409-444

[email protected]

CM

SE

®, I

nd

ura

NE

T p

®, P

AS

40

00

®, P

AS

cal

®, P

AS

con

fig

®, P

ilz

®, P

IT®

, PL

ID®

, PM

Cp

rim

, PM

Cp

rote

go

®, P

MC

ten

do

®, P

MD

®, P

MI

®, P

NO

, Pri

mo

®, P

SE

, PS

, PV

IS®

, Sa

fety

BU

S p

®,

Sa

fety

EY

, Sa

fety

NE

T p

®, t

he

sp

irit

of

safe

ty®

are

re

gis

tere

d a

nd

pro

tect

ed

tra

de

ma

rks

of

Pil

z G

mb

H &

Co

. KG

in s

om

e c

ou

ntr

ies.

We

wo

uld

po

int

ou

t th

at

pro

du

ct f

ea

ture

s m

ay

va

ry

fro

m t

he

de

tail

s st

ate

d in

th

is d

ocu

me

nt,

de

pe

nd

ing

on

th

e s

tatu

s a

t th

e t

ime

of

pu

bli

cati

on

an

d t

he

sco

pe

of

the

eq

uip

me

nt.

We

acc

ep

t n

o r

esp

on

sib

ilit

y f

or

the

va

lid

ity

, acc

ura

cy

an

d e

nti

rety

of

the

te

xt

an

d g

rap

hic

s p

rese

nte

d in

th

is in

form

ati

on

. Ple

ase

co

nta

ct o

ur

Tech

nic

al S

up

po

rt if

yo

u h

av

e a

ny

qu

est

ion

s.

Pilz develops environmentally-friendly products using

ecological materials and energy-saving technologies.

products and environmentally-friendly solutions.

Pilz GmbH & Co. KG

Felix-Wankel-Straße 2

73760 Ostfildern, Germany

Tel.: +49 711 3409-0

Fax: +49 711 3409-133

[email protected]

www.pilz.com

10

0X

XX

X-D

E-0

X

0-0

-2-3

-00

0, 2

01

4-0

0 P

rin

ted

in G

erm

an

y

© P

ilz G

mb

H &

Co

. KG

, 20

14

1003

401­EN­01, 201

4­12

 Prin

ted in G

erman

y© Pilz G

mbH

 & C

o. KG, 2

011

Front cover