From: Brad EvansTo: Planning DepartmentSubject: RE: DA-2016-124 Assessment Manager Information RequestDate: Friday, 20 January 2017 3:09:10 PMAttachments: GQ966 - RPEQ Letter - P56-1ds1.17.pdf
GQ966 - WD"s REV 1 for Build App Lot 27 Ian Reddacliff Dr - Rowe.pdf
Please find attached letter as requested on Information request for DA2016-124 dated 21st December2016. Also attached is an amended plan showing the surface irrigation area relocated in accordancewith the requirements of the letter.
Please let me know if there is any further information required.
mailto:[email protected]:[email protected]:[email protected]://www.mackay.qld.gov.au/Queensland ● Brisbane South (Acacia Ridge) ● Brisbane North (Geebung) ● Cairns ● Townsville Whitsunday ● Mackay ● Moranbah ● Emerald ● Rockhampton ● Gladstone ● Sunshine Coast ● Gold Coast New South Wales ● Sydney ● Coffs Harbour Victoria ● Bendigo ● Tullamarine ● Geelong Western Australia ● Perth ● Bunbury Northern Territory ● Berrimah
Cardno Construction Sciences Pty Ltd ABN 74 128 806 735
1 Fox Road Acacia Ridge QLD 4110 Australia PO Box 253 Acacia Ridge QLD 4110 Australia Phone: 61 7 3320 8500 www.cardno.com.au
Our Ref 1979E/P56-1ds1.17 Contact David Stirling 20 January 2017 Kelwin Gray Cardno Construction Sciences E: [email protected] Dear Kel STABILITY OF RESIDENTIAL DEVELOPMENT LOT 27 REDDACLIFFE DVE, THE LEAP It is understood that following our report (ref: 5676/P/1912 dated 20 April 2015), it has been proposed by the owner to move the proposed house location closer to the road. The residence has a proposed effluent disposal area plan already provided. As such, Council have requested a letter by an RPEQ that moving the residence will not affect the stability of the land and will have a low level of landslide risk. The house is currently situated upslope of the effluent system and moving the house closer to the road will be further upslope. The proposed change of the house position will not impact where the effluent disposal area is to be situated in relation to the house. The effluent disposal area must remain downslope of the house and at least 10m from the proposed house position. The effluent disposal assessment will not be affected by the change in house position and the slope stability of the house and the lot will not change from our original report. Thus, as per our previous report, the proposed residential development on the allotment has a long term stability assessment of ‘low’ provided the recommendation in our report are adhered to, and adequate civil/hydraulic and structural issues are addressed. Should you require further information or have any queries, please contact the undersigned on 3320 8500. Yours faithfully
David Stirling Senior Geotechnical Engineer RPEQ 8820 for Cardno
mailto:[email protected]
Our Ref 1979E/P56-1ds1.17
Contact David Stirling
Dear Kel
STABILITY OF RESIDENTIAL DEVELOPMENT
LOT 27 REDDACLIFFE DVE, THE LEAP
It is understood that following our report (ref: 5676/P/1912 dated 20 April 2015), it has been proposed by the owner to move the proposed house location closer to the road. The residence has a proposed effluent disposal area plan already provided. ...
The house is currently situated upslope of the effluent system and moving the house closer to the road will be further upslope.
The proposed change of the house position will not impact where the effluent disposal area is to be situated in relation to the house. The effluent disposal area must remain downslope of the house and at least 10m from the proposed house position. T...
Thus, as per our previous report, the proposed residential development on the allotment has a long term stability assessment of ‘low’ provided the recommendation in our report are adhered to, and adequate civil/hydraulic and structural issues are addr...
Should you require further information or have any queries, please contact the undersigned on 3320 8500.
Yours faithfully
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:40 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
COVER PAGE
GQ966
01
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Drawing ListSheet Number Sheet Name
01 COVER PAGE02 SITE PLAN03 FLOOR PLAN - Lower04 FLOOR PLAN - Upper05 SLAB SETOUT PLAN06 BLOCKWORK SETOUT PLAN - Lower07 BLOCKWORK SETOUT PLAN - Upper08 BLOCKWORK REINFORCEMENT - Lower09 BLOCKWORK REINFORCEMENT - Upper10 ELEVATIONS 1 & 1a11 ELEVATIONS 2 & 312 ELEVATIONS 3a & 413 SECTION A14 SECTIONS15 SECTIONS16 CLADDING DETAILS17 CLADDING DETAILS18 ROOF DRAINAGE PLAN19 DRAINAGE PLAN - Site20 DRAINAGE PLAN - Lower21 DRAINAGE PLAN -Upper22 ELECTRICAL PLAN23 CONCRETE PLAN24 FLOOR TILING
FORNew Dwelling
Lesley & Jeffrey Rowe
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Elec HW
U
Clo
thes
line
ELEC
M.B
OX
Elec
HW
U
WA
TERTA
P
WATERTAP
WF
PROPOSED DWELLING
PROPOSEDDRIVEWAY
318 ° 5 5' 10"
275 .04 0 m
206° 31
' 53"
1.742 m 299° 15' 00"
3.580 m
214° 45' 30"
36.335 m
230° 20' 00"
11.925 m
140°
33'
20"
26.9
60 m
227° 58' 30"
15.330 m
158°
28'
45"
469.
730
m
Elec M
ains
Nw
es
Water
Connection
Non standard Setbacksubject to ConcurrenceAgency Approval.
AWTS
Surface Spray Irrigation Minimum 290m²constructed as detailed in Cardno Pty Ltd Report5676/P/1912 Dated 14th April 2015
AssumedErgon Pillar
9800
12849
15296
IAN REDDACLIFF
E DRIVE
Assum
ed
60 0045 00
8200
4500
Feature front fencing & Gates by others
Feature front fencing& Gates by others
+187800
+190000
24402200
2200
3000
4000
10000
318 ° 5 5' 10"
275 .04 0 m
206° 31' 53"
1.742 m
299° 15' 00"
3.580 m
214° 45' 30"
36.335 m
230° 20' 00"
11.925 m
140° 33' 20"
26.960 m
227° 58' 30"
15.330 m
158°
28'
45"
469.
730
m
Nw
es
IAN REDDACLIFF
E DRIVE
6° 58
' 40"
300.2
40 m
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY As indicated
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:43 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
SITE PLAN
GQ966
02
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Real Property Description
LOT No.
PLAN No.
PARISH
COUNTY
AREA
GFA
SITE COVERAGE 1.51%
27
SP172242
HAMPDEN
CARLISLE
21790.00 m²
328.39 m²
re: 1 : 200 1 10
1 Site Plan - 1 to 2001
re: 1 : 2000 1 10
1 Site Plan - 1 to 20002
12
10
12
1
Elevation 3 - a
2
Elev
atio
n 4
1
Elevation 1
200
7900
200
4000
200
3200
3200
200
2002000
200
4200
200
4000
200
7900
200
Void forDrainageStack
Foyer
TV
Kitchen
Living
WIR
WC
Ens
Dining
Bedroom 1
Tile Shelf Recess-Bottom1500AFFL Top 1900 AFFL
2060
Drawers
Drawers
2122FG
2112
FG
1818 SW 1512 XO 2115SGD
1512
XO
2448 PANELIFT
Pivot
2113FG
SSGD 2148 O
XXXXO
SSGD 2134 O
XX
2109DH
0421 SW
0421 SW
0421 SW
SSGD 2134 O
XX
SSGD 2134 O
XX
SSGD 2148 O
XXXXO
2113FG
3670See DetailElevation
for Windowset out
0618 SW
700
1000
1000
600
600
2600
FGC 2132
10
2Eleva
tion 1 - a
Roll
Alfresco
Bed 1 Balcony
PorticoStep
Step
Linen
820
820
720
820
2460
2460
820
+188400
+188100
+187900
Study
+187900
+187900
+187800
600
6200 200
200 2920 70 1340 70 1600 200
70 960 70 1980 200
200 3950 70 1980 200
4002
0060
0090
1180
7027
6020
060
0
600
200
1730
7022
1090
200 6000 200
200
8100
4000
200
3130
7093070
2200
200
1600200
96035 Packer
70
5935
2001000
10001000
200
3670
70
3060
200800
2002130
140
4130
200
4000
200
7900
200
100
11
2
Elevation 3
111
Elevation 2
Garage
P'w
dr
L'dry
+188000
Foyer walls tohave verticle
35mm batten @600mm centres for
fixing ofPlasterboard
2 de
gree
Rak
ed C
elin
g
4100
300
Desk by others
3000
1500
1000
1200
1000
1500
3000
WO
MW
350900
350
810
1320140
930
470
470
520
IroningBoard
byothers
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:48 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
FLOOR PLAN - Lower
GQ966
03
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
FLOOR AREAS
1 Living Area - Lower 185.39 m²2 Living Area - Upper 56.62 m²3 VOID Area Upper 33.09 m²4 Garage 38.91 m²5 Portico 4.74 m²6 Portico Ceiling Extension 7.65 m²7 Porch - Front 10.30 m²8 Porch - Front Extended Slab 11.89 m²9 Balcony Bed 1 8.89 m²10 Bed 1Ext Ceiling only 2.72 m²11 Alfresco 45.71 m²12 Rear Foyer External Ceiling Extended 9.20 m²Grand total 415.10 m²
DESIGN PARAMETERSDESIGN WIND SPEED
SOIL CLASSIFICATION
FRAMING DESIGN
SLAB & FOOTING DESIGN
C2
CLASS 'P'
TO AS1684
TO AS2870
S SMOKE ALARM
FW FLOOR WASTE
SYMBOL LEGEND
ELEVATIONS
2
3
4
1
NOTE:SEE ROOF DRAINAGE PLAN FORDOWNPIPE LOCATIONS.
NOTES1) WALL FRAMES SHOWNNOMINAL SIZE. REFER ENGINEERSDETAILS.2) TRUE DIMENSIONS TAKEPRECEDENCE OVER SCALEDDIMENSIONS. IF A DISCREPENCYOCCURS CONTACT GEMINIHOMES.
re: 1 : 100 1 10
2a Floor Level - Lower1
UP
AC
UnitA
C Unit
AC
Unit
AC
Uni
tA
C U
nit
AC
Uni
tA
C U
nit
Bath
Storage
Retreat
Bedroom 3Bedroom 2
Dbl R
ail
Tile Shelf Recess-Bottom1500AFFL Top 1900 AFFL
SW 0
627
OXX
O
1150
0
2122FG
1221 SW
1824 SW1824 SW
2118FG
820
720
820Bifold 4/720
600
200
2760
7012
0070
3330
7031
1090
6200 200
70 1740 70 1200 200
3120 70 960 70 1980 200
6400
200 2900 70 3030 200
70 6130 200
200
4010
7033
5070
3110
90
200
1700
300
5880
9026
4090
Void
Void
1900
3200
300
405
7094
0
70
1900
70
960
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:50 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
FLOOR PLAN - Upper
GQ966
04
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Author
re: 1 : 100 1 10
2b Floor Level - Upper1
FLOOR AREAS
1 Living Area - Lower 185.39 m²2 Living Area - Upper 56.62 m²3 VOID Area Upper 33.09 m²4 Garage 38.91 m²5 Portico 4.74 m²6 Portico Ceiling Extension 7.65 m²7 Porch - Front 10.30 m²8 Porch - Front Extended Slab 11.89 m²9 Balcony Bed 1 8.89 m²10 Bed 1Ext Ceiling only 2.72 m²11 Alfresco 45.71 m²12 Rear Foyer External Ceiling Extended 9.20 m²Grand total 415.10 m²
@ GL - Garage Builidng PadRL +187800@ FFL - Study & LaundryRL +188100
@ Head - Study & LaundryRL +190200@ Ceiling - Garage Study & LaundryRL +190800
@ Ceiling - UpperRL +193700@ Head - UpperRL +193300
@ FFL - Upper FloorRL +191200
@ FFL - FoyerRL +188400
@ FFL - GarageRL +188000
2800
Ga
rage
Cei
ling
200
2500
400
2700
300
5300
Foy
er C
eilin
g60
0
5.50°5.50°
5.50°
@GL - Main Living Area Pad RL +187500@FFL - Main Living Area RL +187900
@Ceiling - Main Living Area RL +190900
@Head - Main Living Area RL +190000
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:53 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
ELEVATIONS 1 & 1a
GQ966
10
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
re: 1 : 100 1 03
Elevation 11
re: 1 : 100 1 03
Elevation 1 - a2
@GL - Garage Builidng Pad RL +187800
@FFL - Study & Laundry RL +188100
@Head - Study & Laundry RL +190200@Ceiling - Garage Study & Laundry RL +190800
@ GL - Main Living Area PadRL +187500
@Ceiling - Upper RL +193700@Head - Upper RL +193300
@FFL - Upper Floor RL +191200
@FFL - Foyer RL +188400@ FFL - Main Living AreaRL +187900@FFL - Garage RL +188000
@ Ceiling - Main Living AreaRL +190900
@ Head - Main Living AreaRL +190000
200
2800
300
2700
400
2500
2400
400
2500
5300
400
3000
2100
900
@FFL - Study & Laundry RL +188100
@Head - Study & Laundry RL +190200
@ GL - Main Living Area PadRL +187500
@Ceiling - Upper RL +193700@Head - Upper RL +193300
@FFL - Upper Floor RL +191200
@FFL - Foyer RL +188400@ FFL - Main Living AreaRL +187900
@FFL - Garage RL +188000
@ Ceiling - Main Living AreaRL +190900
@ Head - Main Living AreaRL +190000
5.50°5.50°
2.00
°
5.50°
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:57 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
ELEVATIONS 2 & 3
GQ966
11
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
re: 1 : 100 1 03
Elevation 21
re: 1 : 100 1 03
Elevation 32
@GL - Garage Builidng Pad RL +187800@FFL - Study & Laundry RL +188100
@Head - Study & Laundry RL +190200@Ceiling - Garage Study & Laundry RL +190800
@Ceiling - Upper RL +193700@Head - Upper RL +193300
@FFL - Upper Floor RL +191200
@FFL - Foyer RL +188400
2700
400
2500
5300
@ GL - Garage Builidng PadRL +187800
@ FFL - Study & LaundryRL +188100
@ Head - Study & LaundryRL +190200@ Ceiling - Garage Study & LaundryRL +190800
@ Ceiling - UpperRL +193700@ Head - UpperRL +193300
@ FFL - Upper FloorRL +191200
@ FFL - GarageRL +188000
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:03:00 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
ELEVATIONS 3a & 4
GQ966
12
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Author
re: 1 : 100 1 03
Elevation 3 - a1
re: 1 : 100 1 03
Elevation 42
Sheets
01 - COVER PAGE
02 - SITE PLAN
03 - FLOOR PLAN - Lower
04 - FLOOR PLAN - Upper
10 - ELEVATIONS 1 & 1a
11 - ELEVATIONS 2 & 3
12 - ELEVATIONS 3a & 4
desleyhReceived (Auto Date)
Queensland ● Brisbane South (Acacia Ridge) ● Brisbane North (Geebung) ● Cairns ● Townsville Whitsunday ● Mackay ● Moranbah ● Emerald ● Rockhampton ● Gladstone ● Sunshine Coast ● Gold Coast New South Wales ● Sydney ● Coffs Harbour Victoria ● Bendigo ● Tullamarine ● Geelong Western Australia ● Perth ● Bunbury Northern Territory ● Berrimah
Cardno Construction Sciences Pty Ltd ABN 74 128 806 735
1 Fox Road Acacia Ridge QLD 4110 Australia PO Box 253 Acacia Ridge QLD 4110 Australia Phone: 61 7 3320 8500 www.cardno.com.au
Our Ref 1979E/P56-1ds1.17 Contact David Stirling 20 January 2017 Kelwin Gray Cardno Construction Sciences E: [email protected] Dear Kel STABILITY OF RESIDENTIAL DEVELOPMENT LOT 27 REDDACLIFFE DVE, THE LEAP It is understood that following our report (ref: 5676/P/1912 dated 20 April 2015), it has been proposed by the owner to move the proposed house location closer to the road. The residence has a proposed effluent disposal area plan already provided. As such, Council have requested a letter by an RPEQ that moving the residence will not affect the stability of the land and will have a low level of landslide risk. The house is currently situated upslope of the effluent system and moving the house closer to the road will be further upslope. The proposed change of the house position will not impact where the effluent disposal area is to be situated in relation to the house. The effluent disposal area must remain downslope of the house and at least 10m from the proposed house position. The effluent disposal assessment will not be affected by the change in house position and the slope stability of the house and the lot will not change from our original report. Thus, as per our previous report, the proposed residential development on the allotment has a long term stability assessment of ‘low’ provided the recommendation in our report are adhered to, and adequate civil/hydraulic and structural issues are addressed. Should you require further information or have any queries, please contact the undersigned on 3320 8500. Yours faithfully
David Stirling Senior Geotechnical Engineer RPEQ 8820 for Cardno
mailto:[email protected]
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:40 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
COVER PAGE
GQ966
01
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Drawing ListSheet Number Sheet Name
01 COVER PAGE02 SITE PLAN03 FLOOR PLAN - Lower04 FLOOR PLAN - Upper05 SLAB SETOUT PLAN06 BLOCKWORK SETOUT PLAN - Lower07 BLOCKWORK SETOUT PLAN - Upper08 BLOCKWORK REINFORCEMENT - Lower09 BLOCKWORK REINFORCEMENT - Upper10 ELEVATIONS 1 & 1a11 ELEVATIONS 2 & 312 ELEVATIONS 3a & 413 SECTION A14 SECTIONS15 SECTIONS16 CLADDING DETAILS17 CLADDING DETAILS18 ROOF DRAINAGE PLAN19 DRAINAGE PLAN - Site20 DRAINAGE PLAN - Lower21 DRAINAGE PLAN -Upper22 ELECTRICAL PLAN23 CONCRETE PLAN24 FLOOR TILING
FORNew Dwelling
Lesley & Jeffrey Rowe
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Elec HW
U
Clo
thes
line
ELEC
M.B
OX
Elec
HW
U
WA
TERTA
P
WATERTAP
WF
PROPOSED DWELLING
PROPOSEDDRIVEWAY
318 ° 5 5' 10"
275 .04 0 m
206° 31
' 53"
1.742 m 299° 15' 00"
3.580 m
214° 45' 30"
36.335 m
230° 20' 00"
11.925 m
140°
33'
20"
26.9
60 m
227° 58' 30"
15.330 m
158°
28'
45"
469.
730
m
Elec M
ains
Nw
es
Water
Connection
Non standard Setbacksubject to ConcurrenceAgency Approval.
AWTS
Surface Spray Irrigation Minimum 290m²constructed as detailed in Cardno Pty Ltd Report5676/P/1912 Dated 14th April 2015
AssumedErgon Pillar
9800
12849
15296
IAN REDDACLIFF
E DRIVE
Assum
ed
60 0045 00
8200
4500
Feature front fencing & Gates by others
Feature front fencing& Gates by others
+187800
+190000
24402200
2200
3000
4000
10000
318 ° 5 5' 10"
275 .04 0 m
206° 31' 53"
1.742 m
299° 15' 00"
3.580 m
214° 45' 30"
36.335 m
230° 20' 00"
11.925 m
140° 33' 20"
26.960 m
227° 58' 30"
15.330 m
158°
28'
45"
469.
730
m
Nw
es
IAN REDDACLIFF
E DRIVE
6° 58
' 40"
300.2
40 m
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY As indicated
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:43 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
SITE PLAN
GQ966
02
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Real Property Description
LOT No.
PLAN No.
PARISH
COUNTY
AREA
GFA
SITE COVERAGE 1.51%
27
SP172242
HAMPDEN
CARLISLE
21790.00 m²
328.39 m²
re: 1 : 200 1 10
1 Site Plan - 1 to 2001
re: 1 : 2000 1 10
1 Site Plan - 1 to 20002
12
10
12
1
Elevation 3 - a
2
Elev
atio
n 4
1
Elevation 1
200
7900
200
4000
200
3200
3200
200
2002000
200
4200
200
4000
200
7900
200
Void forDrainageStack
Foyer
TV
Kitchen
Living
WIR
WC
Ens
Dining
Bedroom 1
Tile Shelf Recess-Bottom1500AFFL Top 1900 AFFL
2060
Drawers
Drawers
2122FG
2112
FG
1818 SW 1512 XO 2115SGD
1512
XO
2448 PANELIFT
Pivot
2113FG
SSGD 2148 O
XXXXO
SSGD 2134 O
XX
2109DH
0421 SW
0421 SW
0421 SW
SSGD 2134 O
XX
SSGD 2134 O
XX
SSGD 2148 O
XXXXO
2113FG
3670See DetailElevation
for Windowset out
0618 SW
700
1000
1000
600
600
2600
FGC 2132
10
2Eleva
tion 1 - a
Roll
Alfresco
Bed 1 Balcony
PorticoStep
Step
Linen
820
820
720
820
2460
2460
820
+188400
+188100
+187900
Study
+187900
+187900
+187800
600
6200 200
200 2920 70 1340 70 1600 200
70 960 70 1980 200
200 3950 70 1980 200
4002
0060
0090
1180
7027
6020
060
0
600
200
1730
7022
1090
200 6000 200
200
8100
4000
200
3130
7093070
2200
200
1600200
96035 Packer
70
5935
2001000
10001000
200
3670
70
3060
200800
2002130
140
4130
200
4000
200
7900
200
100
11
2
Elevation 3
111
Elevation 2
Garage
P'w
dr
L'dry
+188000
Foyer walls tohave verticle
35mm batten @600mm centres for
fixing ofPlasterboard
2 de
gree
Rak
ed C
elin
g
4100
300
Desk by others
3000
1500
1000
1200
1000
1500
3000
WO
MW
350900
350
810
1320140
930
470
470
520
IroningBoard
byothers
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:48 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
FLOOR PLAN - Lower
GQ966
03
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
FLOOR AREAS
1 Living Area - Lower 185.39 m²2 Living Area - Upper 56.62 m²3 VOID Area Upper 33.09 m²4 Garage 38.91 m²5 Portico 4.74 m²6 Portico Ceiling Extension 7.65 m²7 Porch - Front 10.30 m²8 Porch - Front Extended Slab 11.89 m²9 Balcony Bed 1 8.89 m²10 Bed 1Ext Ceiling only 2.72 m²11 Alfresco 45.71 m²12 Rear Foyer External Ceiling Extended 9.20 m²Grand total 415.10 m²
DESIGN PARAMETERSDESIGN WIND SPEED
SOIL CLASSIFICATION
FRAMING DESIGN
SLAB & FOOTING DESIGN
C2
CLASS 'P'
TO AS1684
TO AS2870
S SMOKE ALARM
FW FLOOR WASTE
SYMBOL LEGEND
ELEVATIONS
2
3
4
1
NOTE:SEE ROOF DRAINAGE PLAN FORDOWNPIPE LOCATIONS.
NOTES1) WALL FRAMES SHOWNNOMINAL SIZE. REFER ENGINEERSDETAILS.2) TRUE DIMENSIONS TAKEPRECEDENCE OVER SCALEDDIMENSIONS. IF A DISCREPENCYOCCURS CONTACT GEMINIHOMES.
re: 1 : 100 1 10
2a Floor Level - Lower1
UP
AC
UnitA
C Unit
AC
Unit
AC
Uni
tA
C U
nit
AC
Uni
tA
C U
nit
Bath
Storage
Retreat
Bedroom 3Bedroom 2
Dbl R
ail
Tile Shelf Recess-Bottom1500AFFL Top 1900 AFFL
SW 0
627
OXX
O
1150
0
2122FG
1221 SW
1824 SW1824 SW
2118FG
820
720
820Bifold 4/720
600
200
2760
7012
0070
3330
7031
1090
6200 200
70 1740 70 1200 200
3120 70 960 70 1980 200
6400
200 2900 70 3030 200
70 6130 200
200
4010
7033
5070
3110
90
200
1700
300
5880
9026
4090
Void
Void
1900
3200
300
405
7094
0
70
1900
70
960
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:50 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
FLOOR PLAN - Upper
GQ966
04
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Author
re: 1 : 100 1 10
2b Floor Level - Upper1
FLOOR AREAS
1 Living Area - Lower 185.39 m²2 Living Area - Upper 56.62 m²3 VOID Area Upper 33.09 m²4 Garage 38.91 m²5 Portico 4.74 m²6 Portico Ceiling Extension 7.65 m²7 Porch - Front 10.30 m²8 Porch - Front Extended Slab 11.89 m²9 Balcony Bed 1 8.89 m²10 Bed 1Ext Ceiling only 2.72 m²11 Alfresco 45.71 m²12 Rear Foyer External Ceiling Extended 9.20 m²Grand total 415.10 m²
@ GL - Garage Builidng PadRL +187800@ FFL - Study & LaundryRL +188100
@ Head - Study & LaundryRL +190200@ Ceiling - Garage Study & LaundryRL +190800
@ Ceiling - UpperRL +193700@ Head - UpperRL +193300
@ FFL - Upper FloorRL +191200
@ FFL - FoyerRL +188400
@ FFL - GarageRL +188000
2800
Ga
rage
Cei
ling
200
2500
400
2700
300
5300
Foy
er C
eilin
g60
0
5.50°5.50°
5.50°
@GL - Main Living Area Pad RL +187500@FFL - Main Living Area RL +187900
@Ceiling - Main Living Area RL +190900
@Head - Main Living Area RL +190000
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:53 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
ELEVATIONS 1 & 1a
GQ966
10
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
re: 1 : 100 1 03
Elevation 11
re: 1 : 100 1 03
Elevation 1 - a2
@GL - Garage Builidng Pad RL +187800
@FFL - Study & Laundry RL +188100
@Head - Study & Laundry RL +190200@Ceiling - Garage Study & Laundry RL +190800
@ GL - Main Living Area PadRL +187500
@Ceiling - Upper RL +193700@Head - Upper RL +193300
@FFL - Upper Floor RL +191200
@FFL - Foyer RL +188400@ FFL - Main Living AreaRL +187900@FFL - Garage RL +188000
@ Ceiling - Main Living AreaRL +190900
@ Head - Main Living AreaRL +190000
200
2800
300
2700
400
2500
2400
400
2500
5300
400
3000
2100
900
@FFL - Study & Laundry RL +188100
@Head - Study & Laundry RL +190200
@ GL - Main Living Area PadRL +187500
@Ceiling - Upper RL +193700@Head - Upper RL +193300
@FFL - Upper Floor RL +191200
@FFL - Foyer RL +188400@ FFL - Main Living AreaRL +187900
@FFL - Garage RL +188000
@ Ceiling - Main Living AreaRL +190900
@ Head - Main Living AreaRL +190000
5.50°5.50°
2.00
°
5.50°
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:02:57 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
ELEVATIONS 2 & 3
GQ966
11
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
re: 1 : 100 1 03
Elevation 21
re: 1 : 100 1 03
Elevation 32
@GL - Garage Builidng Pad RL +187800@FFL - Study & Laundry RL +188100
@Head - Study & Laundry RL +190200@Ceiling - Garage Study & Laundry RL +190800
@Ceiling - Upper RL +193700@Head - Upper RL +193300
@FFL - Upper Floor RL +191200
@FFL - Foyer RL +188400
2700
400
2500
5300
@ GL - Garage Builidng PadRL +187800
@ FFL - Study & LaundryRL +188100
@ Head - Study & LaundryRL +190200@ Ceiling - Garage Study & LaundryRL +190800
@ Ceiling - UpperRL +193700@ Head - UpperRL +193300
@ FFL - Upper FloorRL +191200
@ FFL - GarageRL +188000
DATECLIENT
PROJECT ADDRESS
This plan is exclusively owned by Gemini Homes Pty Ltd and must not be copied orreproduced wholly or in part in any form without written permission of Gemini Homes PtyLtd. This includes making changes with intent to change the plan by 10% or more. Any
infringement on this copy-right will result in legal action being taken by Gemini Homes PtyLtd against all persons involved.
COPYRIGHT © GEMINI HOMES (QLD) PTY LTD
All plans are shown for illustrative purposes only and Gemini Homes Pty Ltd reserves the rightto amend plans, specifications and prices without notice or obligation.
www.geminihomes.com.auABN 52 124 700 287QBSA No. 1016033
ISSU
E N
O. NUMBER DATE DESCRIPTION
5 Milton St, Mackay
p (07) 4951 2664f (07) 4951 3664
Po Box 6931MMC QLD 4741
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH"THE BUILDING CODE OF AUSTRALIA" and"THE QUEENSLAND DEVELOPMENT CODE"
"STANDARD BUILDING REGULATIONS""TIMBER FRAMING CODE AS 1684 - 2006"
GEMINI HOMES (QLD) PTY LTD SCALE
PAGE
DRAWING NO.
OF
PROJECT
DRAWN BY
ISSUED FOR BUILDING APPROVAL
CHECKED BY B Evans
Title
blo
ck V
ersio
n : 3
ISSUED BY 1 : 100
R:\GEMINI HOMES\SECTION - ESTIMATING & DRAFTING\01 - QUOTE DOCUMENTS\L3261 - Rowe (GHQ)\REVIT FILES\GQ966 - WD's Lot 27 Ian Reddacliff Dr - Rowe.rvt
20/01/2017 3:03:00 PM
Lot 27 Ian Reddacliff Drive, THELEAP, QLD 4740
Lesley & Jeffrey Rowe
ELEVATIONS 3a & 4
GQ966
12
New Dwelling
24Relocated Surface Irrigation area as required by Cardno report20/01/20161
Author
re: 1 : 100 1 03
Elevation 3 - a1
re: 1 : 100 1 03
Elevation 42
GQ966 - RPEQ Letter - P56-1ds1.17.pdfOur Ref 1979E/P56-1ds1.17Contact David StirlingDear KelSTABILITY OF RESIDENTIAL DEVELOPMENTLOT 27 REDDACLIFFE DVE, THE LEAPIt is understood that following our report (ref: 5676/P/1912 dated 20 April 2015), it has been proposed by the owner to move the proposed house location closer to the road. The residence has a proposed effluent disposal area plan already provided. ...The house is currently situated upslope of the effluent system and moving the house closer to the road will be further upslope.The proposed change of the house position will not impact where the effluent disposal area is to be situated in relation to the house. The effluent disposal area must remain downslope of the house and at least 10m from the proposed house position. T...Thus, as per our previous report, the proposed residential development on the allotment has a long term stability assessment of ‘low’ provided the recommendation in our report are adhered to, and adequate civil/hydraulic and structural issues are addr...Should you require further information or have any queries, please contact the undersigned on 3320 8500.Yours faithfully
GQ966 - WD's REV 1 for Build App Lot 27 Ian Reddacliff Dr - Rowe.pdfSheets01 - COVER PAGE02 - SITE PLAN03 - FLOOR PLAN - Lower04 - FLOOR PLAN - Upper10 - ELEVATIONS 1 & 1a11 - ELEVATIONS 2 & 312 - ELEVATIONS 3a & 4