ELEVATOR LOBBY MEN WOMEN STAIRS NORTH PUBLIC CORRIDOR SOUTH PUBLIC CORRIDOR STAIRS FREIGHT ELEVATOR ELEC. FREIGHT ELEVATOR OFC/ HUDDLE 1906 CALL CENTER 1903 ENTRY 1900 WORK RM 1901 BREAK 1908 CONFERENCE 1905 OPEN WORK AREA 1904 MAX. ALLOWED 100'-0" COMMON PATH OF TRAVEL 92'-4" LS-1 EXIT EXIT TRAVEL DISTANCE: 95'-7" MAX. ALLOWED 300'-0" 315 NET S.F. FE COLLABORATION 1907 IT 1902 EXIT TRAVEL DISTANCE: 151'-2" MAX. ALLOWED 300'-0" L I F E S A F E T Y P L A N - K E Y E D N O T E S L I F E S A F E T Y P L A N - LEGEND EXIT SIGN EXISTING AREA NOT IN CONTRACT EXISTING NON-RATED TENANT SEPARATION PARTITION TO REMAIN NEW NON-RATED, SLAB TO SLAB PARTITION NEW NON-RATED, SLAB TO CEILING PARTITION EXISTING NON-RATED PARTITION TO REMAIN CONSTRUCTION TYPE OCCUPANCY TYPE CODES/GUIDELINES BUILDING INFORMATION BUSINESS, GROUP B FLOOR AREA 2,500 S.F. LOCATION: 19th FLOOR OCCUPANT LOAD EGRESS FLORIDA BUILDING CODE, 5TH EDITION (2014) FLORIDA ACCESSIBILITY CODE, 5TH EDITION (2014) FLORIDA PLUMBING CODE, 5TH EDITION (2014) FLORIDA MECHANICAL CODE, 5TH EDITION (2014) NATIONAL ELECTRIC CODE, 2011 EDITION FLORIDA FIRE PREVENTION CODE NFPA 101: LIFE SAFETY CODE, 2012 EDITION NFPA 72: FIRE ALARM, 2010 EDITION TYPE I-B, SPRINKLERED 32-STORY BUILDING STAIR WIDTH REQUIRED: .3 INCHES PER OCCUPANT = 12.9" PROVIDED: 84" (2 STAIRS TOTAL) BUSINESS - 100 SF/OCCUPANT; 2,185 SF = 22 PEOPLE **ASSEMBLY - 15 SF/OCCUPANT; 315 SF = 21 PEOPLE 43 TOTAL PEOPLE **ASSEMBLY AREA TO HAVE TABLE AND CHAIRS, LAYOUT BY TENANT FUNCTION OF SPACE LS-1 NEW FIRE EXTINGUISHER MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS OF N.F.P.A. 10. PHOENIX MARKETING INTERNATIONAL 400 N ASHLEY DRIVE, SUITE 1975 TAMPA, FLORIDA 33602 ARCHITECTURAL DRAWINGS ENGINEERING DRAWINGS CONSTRUCTION PLAN A1.2 REFLECTED CEILING PLAN A1.3 POWER PLAN A1.4 PARTITION TYPES, ELEVATIONS & DETAILS A2.1 DIAMONDBACK ENGINEERING 1801 N. HIMES AVE. TAMPA, FL 33607 813.517.8254 MECHANICAL PLAN M1 ELECTRICAL SYMBOL LEGEND AND GENERAL NOTES E1 FIRE PROTECTION PLAN FP1 COVER SHEET/LIFE SAFETY PLAN A1.0 DEMOLITION PLAN A1.1 ELECTRICAL DEMOLITION PLAN E2 LIGHTING PLAN E3 POWER & MISC. SYSTEMS PLAN E4 S H E E T N O. S H E E T T I T L E J O B N O. I S S U E D A T E: D R A W N B Y: NO. REVISIONS DATE Drawing Not Valid Unless Signed, Sealed & Dated By Registered Professional INTERIOR RENOVATION PHOENIX MARKETING INTERNATIONAL TAMPA, FLORIDA 33602 1735 07/21/17 400 N ASHLEY DRIVE, SUITE 1975 CC/JL A1.0 COVER SHEET/ LIFE SAFETY PLAN SCALE: 1/8" = 1'-0" 0 1' 5' 10' ISSUED FOR PERMIT 6822 22nd Ave. N. #148 St. Petersburg, Florida 33710 Ph: 727.515.8461 Planning & Design of the Built Environment FL. LIC. NO.: AA26002603 CMK Design Studio, Inc. FINISH PLAN A1.5 PLUMBING PLAN P1 PLUMBING LIST P2 ELECTRICAL PANEL SCHEDULES AND POWER ONE-LINE DIAGRAM E5

PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

ELEVATOR

LOBBY

MEN

WOMEN

STAIRS

NORTH

PUBLIC

CORRIDOR

SOUTH

PUBLIC

CORRIDOR

STAIRS

FREIGHT

ELEVATOR

ELEC.

FREIGHT

ELEVATOR

OFC/

HUDDLE

1906

CALL

CENTER

1903

ENTRY

1900

WORK RM

1901

BREAK

1908

CONFERENCE

1905

OPEN

WORK AREA

1904

MAX. ALLOWED

100'-0"

COMMON PATH

OF TRAVEL 92'-4"

LS-1

EXIT

EXIT TRAVEL

DISTANCE: 95'-7"

MAX. ALLOWED

300'-0"

315 NET S.F.

FE

COLLABORATION

1907

IT

1902

EXIT TRAVEL

DISTANCE: 151'-2"

MAX. ALLOWED

300'-0"

L I F E S A F E T Y P L A N - K E Y E D N O T E S

L I F E S A F E T Y P L A N - LEGEND

EXIT SIGN

EXISTING AREA NOT IN CONTRACT

EXISTING NON-RATED TENANT SEPARATION PARTITION TO REMAIN

NEW NON-RATED, SLAB TO SLAB PARTITION

NEW NON-RATED, SLAB TO CEILING PARTITION

EXISTING NON-RATED PARTITION TO REMAIN

CONSTRUCTION TYPE

OCCUPANCY TYPE

CODES/GUIDELINES

BUILDING INFORMATION

BUSINESS, GROUP B

FLOOR AREA2,500 S.F. LOCATION: 19th FLOOR

OCCUPANT LOAD

EGRESS

FLORIDA BUILDING CODE, 5TH EDITION (2014)

FLORIDA ACCESSIBILITY CODE, 5TH EDITION (2014)

FLORIDA PLUMBING CODE, 5TH EDITION (2014)

FLORIDA MECHANICAL CODE, 5TH EDITION (2014)

NATIONAL ELECTRIC CODE, 2011 EDITION

FLORIDA FIRE PREVENTION CODE

NFPA 101: LIFE SAFETY CODE, 2012 EDITION

NFPA 72: FIRE ALARM, 2010 EDITION

TYPE I-B, SPRINKLERED 32-STORY BUILDING

STAIR WIDTH REQUIRED: .3 INCHES PER OCCUPANT = 12.9"

PROVIDED: 84" (2 STAIRS TOTAL)

BUSINESS - 100 SF/OCCUPANT; 2,185 SF = 22 PEOPLE

**ASSEMBLY - 15 SF/OCCUPANT; 315 SF = 21 PEOPLE

43 TOTAL PEOPLE

**ASSEMBLY AREA TO HAVE TABLE AND CHAIRS, LAYOUT BY

TENANT

FUNCTION OF SPACE

LS-1 NEW FIRE EXTINGUISHER MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS

OF N.F.P.A. 10.

PHOENIX MARKETING

INTERNATIONAL

400 N ASHLEY DRIVE, SUITE 1975

TAMPA, FLORIDA 33602

ARCHITECTURAL DRAWINGS ENGINEERING DRAWINGS

CONSTRUCTION PLANA1.2

REFLECTED CEILING PLANA1.3

POWER PLANA1.4

PARTITION TYPES,

ELEVATIONS & DETAILS

A2.1

DIAMONDBACK ENGINEERING

1801 N. HIMES AVE.

TAMPA, FL 33607

813.517.8254

MECHANICAL PLANM1

ELECTRICAL SYMBOL LEGEND AND

GENERAL NOTES

E1

FIRE PROTECTION PLANFP1

COVER SHEET/LIFE

SAFETY PLAN

A1.0

DEMOLITION PLANA1.1

ELECTRICAL DEMOLITION PLANE2

LIGHTING PLANE3

POWER & MISC. SYSTEMS PLANE4

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

1735

07/21/17

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

CC/JL

A1.0

COVER SHEET/LIFE SAFETY PLAN

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

IS

SU

ED

F

OR

P

ER

MIT

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

FINISH PLANA1.5

PLUMBING PLANP1

PLUMBING LISTP2

ELECTRICAL PANEL SCHEDULES

AND POWER ONE-LINE DIAGRAM

E5

Page 2: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

ELEVATOR

LOBBY

MEN

WOMEN

STAIRS

NORTH

PUBLIC

CORRIDOR

SOUTH

PUBLIC

CORRIDOR

STAIRS

FREIGHT

ELEVATOR

ELEC.

FREIGHT

ELEVATOR

J

E

,

8

2

"

D1

D2

D3

PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY DEMOLITION OR NEW CONSTRUCTION WITH

MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS, AND PROVIDE A UNIFORM, SMOOTH SURFACE.

PREPARE GYPSUM BOARD SURFACES THROUGHOUT TO RECEIVE NEW WALL FINISHES (TO CEILING HEIGHT)

AS SPECIFIED.

ALL ITEMS DASHED ON PLANS ARE EXISTING CONDITIONS TO BE REMOVED. ALL OTHER ITEMS SHOWN ARE

EXISTING CONDITIONS TO REMAIN INSTALLED AND OPERATIONAL.

D E M O L I T I O N P L A N - G E N E R A L N O T E S

2.

1.

D E M O L I T I O N P L A N - K E Y E D N O T E S

D1

P A R T I T I O N L E G E N D

REMOVE ALL VINYL/RUBBER BASE THROUGHOUT AREA OF WORK, UNLESS OTHERWISE NOTED. PATCH AND

REPAIR ALL SURFACES AND OBJECTS AFFECTED BY DEMOLITION AS REQUIRED TO PROVIDE A UNIFORM,

SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES. FLOAT SLAB AS NECESSARY TO MEET TOLERANCE

REQUIREMENTS OF A.C.I. STANDARDS FOR CLASS A OFFICE BUILDINGS (

1

8

" IN 10') TO ACHIEVE A LEVEL

SURFACE FOR THE INSTALLATION OF NEW FLOOR COVERING MATERIALS. CONTRACTOR TO SURVEY

CONDITION OF FLOOR PRIOR TO PROVIDING BID OR STARTING ANY WORK.

D E M O L I T I O N L E G E N D

DISCONNECT FROM SOURCE AND REMOVE EXISTING JUNCTION BOX FROM THIS LOCATION.

PATCH AND REPAIR WALL AS REQUIRED TO PROVIDE A UNIFORM, SMOOTH SURFACE FOR THE

RECEIPT OF NEW FINISHES.

EXISTING NON-RATED PARTITION TO REMAIN INSTALLED

EXISTING AREA NOT IN CONTRACT

J

JUNCTION BOX TO BE REMOVED.

REMOVE ALL EXISTING CEILING TILES, LIGHT FIXTURES, EXIT LIGHTS, CEILING FANS, AND CEILING DEVICES

THROUGHOUT AREA OF WORK (REFER TO REFLECTED CEILING PLAN FOR EXACT EXTENTS). ALL EXISTING

CEILING GRID IS TO REMAIN.

D2

D3

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

1735

07/21/17

CC/JL

A1.1

DEMOLITION PLAN

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

IS

SU

ED

F

OR

P

ER

MIT

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

Page 3: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

ELEVATOR

LOBBY

MEN

WOMEN

STAIRS

NORTH

PUBLIC

CORRIDOR

SOUTH

PUBLIC

CORRIDOR

STAIRS

FREIGHT

ELEVATOR

ELEC.

FREIGHT

ELEVATOR

E

1

3

3

2

3

3

FE

A2.1

4

A

A

B

9'-8 1/2"

1

4

'-

0

"

1

2

1

7

'

-

0

"

7'-0"

5

'

-

0

"

1

3

2 2

1

1

B

B

B

3

1

4

'-

1

1

"

ALIGN

C2

C1

C4

C5

C6

6'-6" 5'-8"

3

ALIGNALIGN

ALIGN

16'-10"

C7

C8

C9

A

L

I

G

N

ALIG

N

A

L

IG

N

A

L

IG

N

A

L

I

G

N

5

'-

4

"

ALIG

N

ALIGN

8

'-

2

"

4'-9"

4'-9"

C3

SIM.

SIM.

3

3

3

SIM.

3

3

'

-

3

"

1

1

'

-

0

"

7"

3

'-

0

"

1

0

"

PROVIDE AND INSTALL NEW PHONE BOARD - 4'W X 8'H X 5/8" TH. FIRE RETARDANT

TREATED PLYWOOD, SKIM COATED, SANDED AND PAINTED WITH (2) COATS OF FIRE

RETARDANT PAINT TO MATCH ADJACENT WALL. COORDINATE WITH TENANT FOR

EXACT MOUNTING HEIGHT AND LOCATION.

FURNISH AND INSTALL NEW BUILDING STANDARD SURFACE MOUNTED FIRE EXTINGUISHER

AT THIS LOCATION, MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS OF

N.F.P.A. 10. SECURELY FASTEN MOUNTING BRACKETS TO BLOCKING, SQUARE AND PLUMB,

TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.

P A R T I T I O N L E G E N D

C O N S T R U C T I O N P L A N - K E Y E D N O T E S

C1

PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY THE REMOVAL OF

POWER, TELE/DATA RECEPTACLE, SWITCH OR JUNCTION BOX AS REQUIRED TO

PROVIDE A UNIFORM, SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.

PROVIDE AND INSTALL NEW BUILDING STANDARD SINGLE BOWL, STAINLESS STEEL,

UNDERMOUNT SINK WITH ADA COMPLIANT FAUCET. COORDINATE WITH MILLWORK

CONTRACTOR AND VERIFY IN FIELD EXACT INSTALLATION LOCATION PRIOR TO THE

EXECUTION OF ANY WORK. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.

PROVIDE AND INSTALL NEW IN-LINE WATER HEATER. COORDINATE WITH MILLWORK

CONTRACTOR AND VERIFY IN FIELD EXACT INSTALLATION LOCATION PRIOR TO THE

EXECUTION OF ANY WORK. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.

PROVIDE AND INSTALL COLD WATER LINE FOR TENANT PROVIDED, CONTRACTOR

INSTALLED REFRIGERATOR. COORDINATE WITH MILLWORK CONTRACTOR AND VERIFY

IN FIELD EXACT INSTALLATION LOCATION PRIOR TO THE EXECUTION OF ANY WORK.

REFER TO M.E.P. DOCUMENTS FOR FURTHER INFORMATION.

C O N S T R U C T I O N P L A N - G E N E R A L N O T E S

1.ALL LABOR, MATERIALS, FINISH REQUIREMENTS, AND THE FINAL FINISHED PRODUCT AS

OUTLINED AND REQUIRED BY THE PLANS, SPECIFICATIONS AND OTHER CONTRACT

DOCUMENTS, SHALL CONFORM WITH THE CURRENT STANDARD EDITION OF THE LOCAL CODES

AND REQUIREMENTS.

ALL DIMENSIONS SHOWN ON PLANS ARE FROM FINISHED FACE OF PARTITION TO FINISHED

FACE OF PARTITION, UNLESS OTHERWISE NOTED.

DISCREPANCIES BETWEEN ARCHITECTURAL AND ENGINEERING DOCUMENTS ARE TO BE

BROUGHT TO THE ATTENTION OF THE TENANT AND DESIGNER IMMEDIATELY UPON DISCOVERY.

SUBMIT IN WRITING TO THE TENANT AND DESIGNER THE NATURE OF THE CONFLICT, THE SHEET

NUMBERS, AND THE SPECIFIC ITEMS FOUND TO BE IN CONFLICT. NOTIFICATION OF CONFLICT

MUST BE REPORTED PRIOR TO SUBMISSION OF BID AND COMMENCEMENT OF WORK.

7.

6.

5.

ALL WORK AND FINISHED EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT SATISFACTORY

TO THE BUILDING MANAGEMENT, TENANT AND DESIGNER.

INSTALL FIRE EXTINGUISHER(S) MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS

AS SET FORTH IN THE CURRENT STANDARD EDITION OF NFPA-10.

CONTRACTOR WILL SECURE ALL BUILDING PERMITS & INSPECTIONS NECESSARY FOR THE

CONSTRUCTION OF THE SPACE.

4.

3.

MAINTENANCE EXCLUSION: THESE DRAWINGS WERE PREPARED FOR PURPOSES OF

CONSTRUCTION ONLY. THESE DRAWINGS ARE NOT TO BE USED FOR MAINTENANCE PURPOSES

AS ACTUAL CONDITIONS MAY VARY FROM THOSE SHOWN ON THE DRAWINGS DUE TO CHANGE

ORDERS, ALTERATIONS BY OTHERS, FIELD CONDITIONS, ETC.

THE TENANT'S WRITTEN AUTHORIZATION MUST BE OBTAINED PRIOR TO THE ORDERING OF ANY

MATERIAL, AWARDING OF ANY CONTRACTS, OR THE EXECUTION OF ANY WORK INVOLVING

EXTRA COST TO THE CONTRACT SUM.

DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.

IF ANY ADDITIONAL WORK OR CHANGES WILL ADVERSELY AFFECT THE COMPLETION

SCHEDULE, THE CONTRACTOR SHALL ADVISE THE TENANT AND DESIGNER IN WRITING OF SUCH

DELAY.

19.

14.

13.

PLANS WERE DEVELOPED FROM INFORMATION SUPPLIED BY THE BUILDING MANAGEMENT AND

EXISTING CONDITIONS OBSERVED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND

DIMENSIONS IN THE FIELD PRIOR TO COMMENCING ANY WORK. ANY DISCREPANCIES BETWEEN

DRAWINGS AND EXISTING CONDITIONS ARE TO BE REPORTED TO THE TENANT, DESIGNER AND

BUILDING MANAGEMENT IN WRITING PRIOR TO STARTING WORK ON A GIVEN ITEM AND BEFORE

INCURRING ANY ADDITIONAL COST.

8.

2.

9.

10.

11.

12.

ALL SPRINKLERS, EITHER EXISTING TO REMAIN, REMOVED AND RELOCATED, AND/OR NEW, ARE

TO COMPLY WITH THE REQUIREMENTS AS SET FORTH IN THE CURRENT STANDARD EDITION OF

NFPA-13.

CONTRACTOR SHALL COORDINATE ALL WOOD BLOCKING, STEEL SUPPORTS AND ANY OTHER

ITEMS WHICH ARE IMBEDDED IN DRYWALL PARTITIONS OR ENCLOSURES WHICH RELATE TO HIS

WORK OR THE WORK OF ANY SEPARATE CONTRACTORS. ALL WOOD BLOCKING, BRIDGING,

BRACING, FRAMING, ETC., SHALL BE FIRE RETARDANT AS CALLED FOR BY THE BUILDING CODE

AND THE CONTRACTOR MUST SUBMIT AFFIDAVITS OF SUCH FIRE RETARDATION TO THE

DESIGNER.

CONTRACTOR TO PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY DEMOLITION

OR NEW CONSTRUCTION WITH MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS

AND TO PROVIDE A UNIFORM NEW CONDITION. PREPARE GYPSUM BOARD WALLS (TO CEILING

HEIGHT) AND ALL OTHER GYPSUM BOARD SURFACES THROUGHOUT TO ACHIEVE A UNIFORM,

SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.

20.

CONTRACTOR TO FIELD SURVEY CONDITION OF EXISTING FLOOR SLAB. PLUG, REPAIR AND

FLOAT SLAB AS NECESSARY TO MEET TOLERANCE REQUIREMENTS OF A.C.I. STANDARDS FOR

CLASS A OFFICE BUILDINGS (1/8" IN 10' ) AND TO ACHIEVE A LEVEL SURFACE FOR THE

INSTALLATION OF NEW FLOOR COVERING MATERIALS.

CONTRACTOR TO SURVEY CONDITION OF EXISTING EXTERIOR WINDOW WALL, KNEE WALL AND

PERIMETER SPANDREL PANELS. PATCH & REPAIR AS NECESSARY WITH MATERIALS AND

METHODS TO MATCH EXISTING CONDITIONS AND TO ACHIEVE A UNIFORM, SMOOTH SURFACE

FOR THE RECEIPT OF NEW FINISHES.

CONTRACTOR TO SURVEY CONDITION OF CORE WALL AND COLUMNS. PATCH & REPAIR AS

NECESSARY WITH MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS AND TO

ACHIEVE A UNIFORM, SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.

CONTRACTOR TO FURR-OUT WALLS, COLUMNS, KNEE WALLS AND PERIMETER SPANDREL

PANELS AS NECESSARY TO ACCOMMODATE NEW DEVICES AND/ OR EQUIPMENT AS SPECIFIED.

15.

16.

17.

18.

CONTRACTOR TO SURVEY CONDITIONS OF BUILDING STANDARD WINDOW TREATMENTS ON ALL

EXTERIOR WINDOWS. REPAIR OR REPLACE WINDOW TREATMENTS AS NECESSARY TO ACHIEVE

A UNIFORM NEW APPEARANCE AND FUNCTION. VERIFY WITH BUILDING MANAGEMENT FOR

BUILDING STANDARD WINDOW TREATMENT SPECIFICATIONS.

EXISTING PARTITION TO REMAIN

NEW SLAB TO CEILING, NON-RATEDPARTITION. SEE PARTITION TYPE 2, SHEET A2.1.

1

2

EXISTING TENANT SEPARATION TO REMAIN

EXISTING AREA NOT IN CONTRACT

NEW SLAB TO SLAB, NON-RATED PARTITION WITH INSULATION. SEE PARTITION

TYPE 1, SHEET A2.1.

ALL INTERIOR FINISHES ARE TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING

CODE - 5TH EDITION, CHAPTER 8, TABLE 803.9.

C2

CONTRACTOR TO PROVIDE AND INSTALL NEW 24 HOUR SUPPLEMENTAL AIR UNIT THIS

ROOM PER TENANT'S REQUIREMENTS. REFER TO M.E.P. DOCUMENTS FOR FURTHER

INFORMATION.

C3

C4

C5

C6

FOLLOW EXISTING RADIUS TO CONTINUE CURVED PARTITION.

C7

C8

C9

PROVIDE AND INSTALL FIRE RETARDANT WOOD BLOCKING IN WALL TO ACCOMMODATE

TV AND/OR EQUIPMENT. COORDINATE EXACT LOCATION/EXTENTS WITH EQUIPMENT

SPECIFICATIONS AND TENANT'S A/V VENDOR.

NEW SLAB TO ABOVE CEILING, NON-RATEDPARTITION. SEE PARTITION TYPE 3,

SHEET A2.1.

3

D O O R S C H E D U L E

1

NEW BUILDING STANDARD DOOR ASSEMBLY:

PROVIDE AND INSTALL NEW 3'-0" WIDE, SOLID CORE, STAIN GRADE

WOOD DOOR, FRAME, HARDWARE AND DOOR STOP TO MATCH BUILDING

STANDARD. PROVIDE CLASSROOM FUNCTION HARDWARE.

2

D O O R G E N E R A L N O T E S

HOLD ALL NEW DOORS 6" OFF THE HINGE SIDE WALL, UNLESS

OTHERWISE NOTED.

ALL HARDWARE MUST BE ADA COMPLIANT.

ALL LOCKS TO BE MASTER-KEYED TO BUILDING STANDARD SYSTEM.

SEE CHIEF BUILDING ENGINEER TO COORDINATE.

ALL HARDWARE FINISH MUST BE BUILDING STANDARD, UNLESS

OTHERWISE NOTED.

4.

3.

1.

2.

5.LOCK FUNCTION DEFINITIONS:

a. Passage Function: Both levers always unlocked.

Classroom Function: Outside lever locked and unlocked by key. Inside

lever always unlocked.

b.

NEW BUILDING STANDARD DOOR ASSEMBLY:

PROVIDE AND INSTALL NEW 3'-0" WIDE, SOLID CORE, STAIN GRADE

WOOD DOOR, FRAME, HARDWARE AND DOOR STOP TO MATCH

BUILDING STANDARD. PROVIDE PASSAGE FUNCTION HARDWARE.

EXISTING BUILDING STANDARD DOUBLE DOOR ASSEMBLY:

PROTECT FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.

E

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

1735

07/21/17

CC/JL

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

IS

SU

ED

F

OR

P

ER

MIT

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

A1.2

CONSTRUCTIONPLAN

Page 4: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

ELEVATOR

LOBBY

MEN

WOMEN

STAIRS

NORTH

PUBLIC

CORRIDOR

SOUTH

PUBLIC

CORRIDOR

STAIRS

FREIGHT

ELEVATOR

ELEC.

FREIGHT

ELEVATOR

N

N

N

N

N

N

N

N

N

N

N

N

N N N

N N N

N

N

N

N N

N

N N

N

N

N

N

N NN

N NN

N

N

N

N

N

N

N

N

N

N

EMERGENCY EXIT LIGHT

BUILDING STANDARD WALL SWITCH, MOUNTED AT 48" A.F.F. TO CENTER OF

SWITCHPLATE (UNLESS OTHERWISE NOTED).

R E F L E C T E D C E I L I N G P L A N - L E G E N D

FIRE SPRINKLERS LOCATED AND INSTALLED THROUGHOUT THE TENANT SPACE SHALL CONFORM WITH THE

REQUIREMENTS OF N.F.P.A.-13. ALL SPRINKLERS TO BE REMOVED, RELOCATED AND/ OR ADDED ARE TO BE

CENTERED IN THE CEILING TILE. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.

COORDINATE WITH TENANT'S SECURITY, CABLING AND AUDIO VISUAL VENDORS FOR COMPLETION OF WORK

PRIOR TO CLOSING UP CEILING.

5.

R E F L E C T E D C E I L I N G P L A N - G E N E R A L N O T E S

INSTALL SMOKE DETECTION DEVICES TO COMPLY WITH ALL CODE REQUIREMENTS. VERIFY IN FIELD WITH

BUILDING MANAGEMENT FOR BUILDING STANDARD DEVICES TO BE USED AND PROCEDURES TO CONNECT TO

BASE BUILDING FIRE ALARM SYSTEM. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.

SUPPLY, INSTALL AND CONNECT ALL EMERGENCY LIGHTING AS PER ALL APPLICABLE CODES AND ORDINANCES.

REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.

2.

4.

1.

MULTIPLE SWITCHES SHOWN AT THE SAME LOCATION ARE TO BE GANGED IN THE SAME SWITCH COVER PLATE.

3.

6.

7.

8.

EXISTING 2'X2' SUSPENDED CEILING GRID SYSTEM. FIELD SURVEY EXISTING GRID

SYSTEM AND ADJUST AS NECESSARY TO MAINTAIN A LEVEL CEILING SURFACE. PROTECT

DURING DEMOLITION AND CONSTRUCTION. REPAIR OR REPLACE CEILING GRID

THROUGHOUT AS NECESSARY TO ACHIEVE A UNIFORM, LIKE NEW APPEARANCE. PROVIDE

AND INSTALL NEW 2'X2' ACOUSTICAL CEILING TILES THROUGHOUT AREA OF WORK.

CEILING TILE TO BE ARMSTRONG, DUNE, WHITE TILE (CLASS A).

RECESSED LED DOWNLIGHT. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATION.

9.

COORDINATE AIR CONDITIONING DUCTWORK ELEVATIONS, BEAM DROPS, PIPING AND ANY OTHER

OBSTRUCTIONS WITH LIGHT FIXTURE DEPTHS AND LOCATIONS TO ASCERTAIN THAT PROPER CLEARANCES CAN

BE MAINTAINED IN ACCORDANCE WITH REQUIRED FINISHED SUSPENDED CEILING HEIGHTS. THIS

COORDINATION SHALL BE DONE BEFORE LIGHT FIXTURES ARE ORDERED AND BEFORE SUSPENDED CEILING

SYSTEM CONSTRUCTION BEGINS. CONTRACTOR SHALL REPORT ANY CONFLICTS OR DISCREPANCIES TO THE

DESIGNER.

ALL NEW SWITCHES AND COVERPLATES SHOWN ARE TO MATCH EXISTING.

2' x 2' FLUORESCENT LIGHT FIXTURE. LIGHT FIXTURES TO BE RELOCATED FROM BUILDING

STOCK. COORDINATE WITH BUILDING MANAGEMENT.

DENOTES EXISTING FIXTURE OR DEVICE TO REMAIN INSTALLED AND OPERATIONAL.

PROTECT DURING DEMOLITION AND CONSTRUCTION.

E

DENOTES EXISTING FIXTURE OR DEVICE SHOWN AT NEW RELOCATED POSITION.R

DENOTES NEW FIXTURE OR DEVICE TO MATCH EXISTING (UNLESS OTHERWISE NOTED)

AND TO BE PROVIDED AND INSTALLED BY CONTRACTOR.

N

WHERE DEMOLITION/ CONSTRUCTION AFFECTS SUSPENDED CEILING SYSTEM, CONTRACTOR SHALL REPLACE

AND/ OR REPAIR EXISTING CEILING GRID AS NECESSARY TO ACHIEVE A UNIFORM, LIKE NEW APPEARANCE.

MATCH NEW CEILING COMPONENTS TO EXISTING ADJACENT CEILING SYSTEM AND ALIGN IN BOTH THE

HORIZONTAL DIMENSION AND THE HEIGHT INSTALLED A.F.F.

EXISTING CEILING CONDITIONS TO REMAIN SHALL BE PROTECTED DURING DEMOLITION AND CONSTRUCTION TO

MAINTAIN ITS EXISTING FINISH CONDITION. CONTRACTOR TO FIELD SURVEY CONDITION OF EXISTING

SUSPENDED ACOUSTICAL CEILING SYSTEM IN THESE AREAS. ADJUST, LEVEL AND RETIE EXISTING CEILING GRID

TO STRUCTURE ABOVE AND/OR REPAIR GRID AS REQUIRED TO MAINTAIN A UNIFORM, LEVEL CEILING SURFACE

AND TO PROVIDE A LIKE NEW APPEARANCE. INSTALL FIXTURES AND DEVICES AS SPECIFIED ON REFLECTED

CEILING PLAN. ALL RELOCATED FIXTURES AND DEVICES ARE TO BE REFURBISHED AND REPAIRED AS

NECESSARY TO ACHIEVE A LIKE NEW APPEARANCE AND FUNCTION. CLEAN AND RE-LAMP ALL FIXTURES AS

NECESSARY TO ACHIEVE A UNIFORM, LEVEL LAMP COLORING AND LIGHT LEVEL.

REFER TO M.E.P. DOCUMENTS FOR ALL LIGHT SWITCHING.

10.

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

1735

07/21/17

CC/JL

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

IS

SU

ED

F

OR

P

ER

MIT

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

A1.3

REFLECTEDCEILING PLAN

Page 5: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

ELEVATOR

LOBBY

MEN

WOMEN

STAIRS

NORTH

PUBLIC

CORRIDOR

SOUTH

PUBLIC

CORRIDOR

STAIRS

FREIGHT

ELEVATOR

ELEC.

FREIGHT

ELEVATOR

N

N

,4

4

",G

F

C

I

N

,IH

,G

F

C

I

N

,

M

I

C

,

4

4

"

N

,

4

W

S

N

,

4

W

S

N

,

R

E

F

N

,

4

4

"

,

G

F

C

I

N

N

N

N

N

,

4

W

S

N

,

4

W

S

N

,4

W

S

N

,4

W

S

N

N

N

N

N

N

N

N

N

N

N

N,C

OP

Y

N,C

OP

Y

N

E

E

E

E E E

E

N

N,C

OP

Y

N,C

OP

Y

N

N

N

N

N

N

N

,T

V

,6

6

"

N

N

N

N

P1

P2

P3

P4

CONTRACTOR TO VERIFY REQUIRED NEMA CONFIGURATION FOR ANY NON-STANDARD

RECEPTACLE(S).

EXISTING WIRING AND CONDUIT ABOVE THE CEILING THAT HAS BEEN ABANDONED SHALL BE

DEMOLISHED/ REMOVED.

DUPLEX VOICE/ DATA COMMUNICATION RECEPTACLE, PLUG-IN TYPE, MOUNTED AT 18" A.F.F. TO CENTER

OF RECEPTACLE (UNLESS OTHERWISE NOTED). EXTEND 3/4" EMPTY CONDUIT WITH PULL-STRING TO 6"

ABOVE SUSPENDED CEILING. TERMINATE WITH INSULATING BUSHING.

DUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT 18" A.F.F. TO CENTER OF RECEPTACLE (UNLESS

OTHERWISE NOTED).

P O W E R / C O M M U N I C A T I O N S L E G E N D

CONTRACTOR TO STAGGER RECEPTACLES ON OPPOSITE SIDE OF WALL BY MINIMUM OF ONE STUD

FOR SOUND ATTENUATION (TYP.).

P O W E R / C O M M U N I C A T I O N S - G E N E R A L N O T E S

3.

2.

1.

P1

P O W E R / C O M M U N I C A T I O N S - K E Y E D N O T E S

4.

DEDICATED DUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT 18" A.F.F. TO CENTER OF RECEPTACLE

(UNLESS OTHERWISE NOTED).

CONTRACTOR TO PROVIDE AND INSTALL NEW COVER PLATES WHERE MISSING OR DAMAGED TO

ACHIEVE A LIKE NEW APPEARANCE THROUGHOUT TENANT SPACE.

5.

6.

7.

8.

CONTRACTOR TO PROVIDE AND INSTALL NEW 24 HOUR SUPPLEMENTAL AIR UNIT THIS ROOM PER

TENANT'S REQUIREMENTS. REFER TO MEP DOCUMENTS FOR SPECIFICATIONS.

ALL NEW RECEPTACLES, COVERPLATES & DEVICES SHOWN ARE TO MATCH EXISTING.

WHEN WIRING IS COMPLETE, ALL AFFECTED PANELS ARE TO BE LABELED.

EXISTING RECEPTACLES ARE TO BE REUSED WHERE THEIR LOCATION COORDINATES WITH THE

LOCATION OF NEW RECEPTACLES. RETROFIT AS REQUIRED TO MATCH NEW RECEPTACLE TYPE AND

STYLE.

DEDICATED QUADRUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT 18" A.F.F. TO CENTER OF

RECEPTACLE (UNLESS OTHERWISE NOTED).

INSTALLATION OF WIRING, RACEWAYS, AND DEVICES FOR AUTOMATIC FIRE ALARM SYSTEM WILL BE

IN ACCORDANCE WITH ALL APPLICABLE CITY CODES, N.F.P.A. CODES AND UNIFORM RULE 4A-48,

RULES AND REGULATIONS OF THE STATE FIRE MARSHAL'S OFFICE, F.S.633.01 AND F.S. 633.701.

REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.

9.

ALL POWER AND COMMUNICATION WIRING, DEVICES AND INSTALLATION SHALL CONFORM WITH THE

CURRENT STANDARD EDITION OF N.F.P.A., NATIONAL ELECTRICAL CODE, I.E.E.E., N.E.M.A., U.L., AND

ANY AND ALL OTHER APPLICABLE REGULATIONS AND ORDINANCES HAVING JURISDICTION OVER THE

SCOPE OF WORK.

10. CONTRACTOR TO PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY THE DEMOLITION

AND ADDITION OF POWER AND COMMUNICATIONS RECEPTACLES WITH MATERIALS AND METHODS

TO MATCH EXISTING CONDITIONS AND TO PROVIDE A UNIFORM NEW CONDITION. PREPARE GYPSUM

BOARD WALLS (TO CEILING HEIGHT) AND ALL OTHER GYPSUM BOARD SURFACES THROUGHOUT TO

ACHIEVE A UNIFORM, SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.

PRIOR TO CORE DRILLING, CONTRACTOR TO COORDINATE WITH THE BUILDING MANAGEMENT FOR

PROPER PROCEDURES, BUILDING RULES AND REGULATIONS REGARDING DRILLING.

11.

MIC

REF

COPY

RECEPTACLE TO SERVICE POWER/ COMMUNICATIONS REQUIREMENTS FOR COPIER.

RECEPTACLE TO SERVICE POWER REQUIREMENTS FOR REFRIGERATOR.

RECEPTACLE TO SERVICE POWER REQUIREMENTS FOR MICROWAVE.

RECEPTACLE TO SERVICE POWER REQUIREMENTS FOR INSTANTANEOUS INLINE WATER HEATER.

44"

44" INDICATES NON-STANDARD MOUNTING HEIGHT A.F.F. TO CENTER OF RECEPTACLE.

GFCIRECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER

E DENOTES EXISTING RECEPTACLE OR CONDITION TO REMAIN INSTALLED AND OPERATIONAL.

NDENOTES NEW RECEPTACLE OR CONDITION TO BE SUPPLIED AND INSTALLED BY CONTRACTOR.

TV

RECEPTACLE TO SERVICE POWER/ COMMUNICATIONS REQUIREMENTS FOR TELEVISION.

IH

#WS

INDICATES NUMBER OF WORKSTATIONS BEING FED BY WHIP OR POWER POLE.

ELECTRICAL WHIP CONNECTION TO TENANT'S WORKSTATION FURNITURE WITH FACEPLATE, MOUNTED

AT 18" A.F.F. TO CENTER OF JUNCTION BOX (UNLESS OTHERWISE NOTED - CONFIRM WITH TENANT'S

FURNITURE VENDOR). EXACT LOCATION TO BE COORDINATED WITH TENANT'S FURNITURE VENDOR IN

FIELD. GENERAL CONTRACTOR TO PROVIDE AND INSTALL QUADRUPLEX JUNCTION BOX, CONDUIT FOR

POWER FEED AND FACEPLATE. TENANT'S FURNITURE VENDOR TO PROVIDE AND CONNECT EACH

ELECTRICAL WHIP TO SYSTEMS FURNITURE. ELECTRICIAN TO TRIM TO MINIMUM LENGTH REQUIRED

FROM SOURCE TO FURNITURE SYSTEM CONNECTION AT PANEL BASE (COORDINATE IN FIELD).

GENERAL CONTRACTOR'S ELECTRICIAN TO PROVIDE FINAL ELECTRICAL CONNECTION.

VOICE/ DATA COMMUNICATION WHIP CONNECTION TO TENANT'S WORKSTATION FURNITURE WITH

FACEPLATE, MOUNTED AT 18" A.F.F. TO CENTER OF JUNCTION BOX (UNLESS OTHERWISE NOTED -

CONFIRM WITH TENANT'S FURNITURE VENDOR). EXACT LOCATION TO BE COORDINATED WITH TENANT'S

FURNITURE VENDOR IN FIELD. GENERAL CONTRACTOR TO PROVIDE AND INSTALL QUADRUPLEX

JUNCTION BOX, CONDUIT FOR VOICE/ DATA CABLE AND FACEPLATE. TENANT'S CABLE CONSULTANT TO

PROVIDE AND INSTALL EACH VOICE/ DATA WHIP IN FLEX CONDUIT TO BE MINIMUM LENGTH REQUIRED

FROM SOURCE TO FURNITURE SYSTEM CONNECTION AT PANEL BASE (COORDINATE IN FIELD).

TENANT'S CABLE CONSULTANT TO PROVIDE FINAL VOICE/ DATA COMMUNICATION CONNECTION.

COORDINATE EXACT LOCATION OF TV AND TV POWER/COMMUNICATIONS RECEPTACLES WITH

TENANT AND EQUIPMENT SPECIFICATIONS. REFER TO M.E.P. DRAWINGS FOR FURTHER

INFORMATION.

FLUSH FLOOR MOUNTED DUAL POWER AND COMMUNICATIONS PLUG-IN RECEPTACLE. REFER TO M.E.P.

DOCUMENTS FOR EXACT SPECIFICATIONS.

FLOOR CORE TO PROVIDE CONDUIT TO ACCOMMODATE HDMI TO WALL MOUNTED TV.

COORDINATE EXACT LOCATION OF FLOOR CORE WITH TENANT IN FIELD PRIOR TO CORE

DRILLING. CONTRACTOR TO COORDINATE EXACT WIRING REQUIREMENTS WITH TENANT AND

TENANT'S FURNITURE VENDOR.

CLOCK TYPE BOX TO ACCOMMODATE DUPLEX POWER, HDMI AND COAX PLUG-IN CONNECTIONS,

MOUNTED AT HEIGHT INDICATED ON PLAN TO CENTER OF RECEPTACLE, LEGRAND, PASS & SEYMOUR

TV2MW OR EQUAL. CABLE CONNECTION BY TENANT'S CABLE VENDOR.

P2

P3

COORDINATE EXACT LOCATION OF FLOOR CORE WITH TENANT IN FIELD PRIOR TO CORE

DRILLING. CONTRACTOR TO COORDINATE EXACT WIRING REQUIREMENTS WITH TENANT AND

TENANT'S FURNITURE VENDOR.

P4

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

1735

07/21/17

CC/JL

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

IS

SU

ED

F

OR

P

ER

MIT

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

A1.4

POWER PLAN

Page 6: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

ELEVATOR

LOBBY

MEN

WOMEN

STAIRS

NORTH

PUBLIC

CORRIDOR

SOUTH

PUBLIC

CORRIDOR

STAIRS

FREIGHT

ELEVATOR

ELEC.

FREIGHT

ELEVATOR

FE

LVT-1

VB-1

PT-1

PT

-2

PT-2

LVT-1

VB-1

PT-1

CPT-1

VB-1

PT-1

CPT-1

VB-1

PT-1

CPT-1

VB-1

PT-1

CPT-1

VB-1

PT-1

CPT-1

VB-1

PT-1

CPT-1

VB-1

PT-1

LVT-1

VB-1

PT-1

CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT ADJACENT SURFACES DURING

INSTALLATION AND TO PROTECT FINAL INSTALLED FINISH MATERIAL(S) FROM OTHER TRADES.

ALL FINISH DESIGNATIONS ARE SHOWN MONUMENTALLY UNLESS KEYED SPECIFICALLY ON PLAN.

ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAMEPROOF IN AN APPROVED MANNER.

ALL MATERIALS SHALL BE INSPECTED FOR FLAWS, DEFECTS OR DISCOLORATION PRIOR TO CUTTING

OR INSTALLATION.

ALL DRAPERY POCKETS, COLUMNS, FASCIAS, SOFFITS, DOOR/WINDOW TRANSOM CONDITIONS, AND

PARTIAL HEIGHT WALLS ARE TO RECEIVE WALL FINISHES AS INDICATED ON PLANS. CONTRACTOR

SHALL VERIFY LOCATION OF ABOVE AND SIMILAR ELEMENTS PRIOR TO DETERMINATION OF BID.

CONTRACTOR TO PROVIDE BUILDING MANAGEMENT AND TENANT WITH COPIES OF MANUFACTURER'S

WRITTEN WARRANTY AND APPROVED MAINTENANCE SPECIFICATIONS IMMEDIATELY UPON

COMPLETION OF WORK.

ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN

SPECIFICATIONS FOR THE PARTICULAR SURFACE. TWO (2) FINISH COATS MINIMUM APPLICATION

AFTER ONE PRIME COAT.

CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK'S COMPLIANCE WITH ALL APPLICABLE LOCAL

CODES, ORDINANCES, AND REGULATIONS AND WITH ALL ACCESSIBILITY REQUIREMENTS AS

OUTLINED IN CHAPTER 11 OF THE FLORIDA BUILDING CODE, AS WELL AS WITH ALL TRADE STANDARDS

OF PROFESSIONAL QUALITY WORKMANSHIP.

CONTRACTOR(S) SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB

SITE WHICH WILL IMPACT OR INTERFACE WITH HIS WORK AND BE RESPONSIBLE FOR SAME. ANY

DISCREPANCIES BETWEEN ACTUAL SITE CONDITIONS AND CONTRACT DOCUMENTS ARE TO BE

BROUGHT TO THE ATTENTION OF THE BUILDING MANAGEMENT AND DESIGNER PRIOR TO THE

COMMENCEMENT OF WORK.

CONTRACTOR(S) SHALL ADHERE TO ALL CURRENT MANUFACTURER WRITTEN SPECIFICATIONS FOR

APPROVED INSTALLATION METHODS (FOR EXAMPLE, BUT NOT LIMITED TO, ADHESIVE TYPES, CUTTING

METHODS, SEALERS AND PRIMERS) AND SHALL INFORM DESIGNER AND BUILDING MANAGEMENT

SHOULD MANUFACTURER NOT HAVE SUCH WRITTEN MATERIAL.

ALL FINISHES ARE TO BE PROVIDED AND INSTALLED BY PROFESSIONAL CONTRACTORS, QUALIFIED

TO INSTALL THE TYPE OF FINISH SPECIFIED.

17.

16.

15.

14.

13.

12.

10.

11.

9.

7.

6.

5.

F I N I S H P L A N - G E N E R A L N O T E S

4.

3.

2.

1.

ALL CHANGES IN FLOOR FINISH MATERIALS OCCURRING AT DOORWAYS SHALL BE AT THE CENTERLINE

OF THE DOOR OR DOORWAY UNLESS NOTED OTHERWISE. ALL OTHER FLOOR FINISH TRANSITIONS

SHALL BE ACCOMPLISHED SMOOTHLY TO THE SATISFACTION OF THE DESIGNER AND BUILDING

MANAGEMENT.

CONTRACTOR SHALL VERIFY LOCATIONS OF ALL CONSTRUCTION AND/ OR MILLWORK WHICH WILL

IMPACT HIS WORK PRIOR TO COMMENCEMENT OF WORK.

8.

ALL MISCELLANEOUS GRILLS, DIFFUSERS, AND FIRE EXTINGUISHER CABINETS OCCURRING ON

PARTITIONS OR CEILINGS ARE TO BE PAINTED TO MATCH THE SURFACE ON WHICH THEY OCCUR.

CONTRACTOR TO PREP ALL WALLS TO RECEIVE BASE AS SCHEDULED ON FINISH PLAN. CONTRACTOR

TO PATCH AND REPAIR WALLS AS REQUIRED TO ACHIEVE A UNIFORM, SMOOTH SURFACE FOR THE

RECEIPT OF NEW VINYL OR WOOD BASE. FLOORS AND WALLS MUST BE CLEAN AND FREE OF DUST,

DIRT, ALL PAINTS, WALL FINISH AND OTHER FOREIGN MATTER, WHICH MAY AFFECT ADHESIVE BONDING

OR MECHANICAL CONNECTION. FOLLOW MANUFACTURER'S WRITTEN SPECIFICATIONS FOR FURTHER

INSTALLATION INSTRUCTIONS.

CONTRACTOR TO PROVIDE ACTUAL SAMPLES OF ALL SPECIFIED FINISHES AND MATERIAL TO CMK

DESIGN STUDIO FOR APPROVAL PRIOR TO ORDERING. SAMPLES SHALL BE SUBMITTED IN A TIMELY

MANNER AS TO NOT IMPACT THE OVERALL PROJECT SCHEDULE.

CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS WITH RESPECT TO NEW INSTALLATION,

PRIOR TO BID PROPOSAL COMPLETION.

DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.18.

COMMENTS

PT-1

GENERAL

PAINT

VB-1

VINYL

BASE

MANUF:

COLOR:

PROFILE:

HEIGHT:

F I N I S H S C H E D U L E

KEY

MANUF:

STYLE:

COLOR:

SIZE:

DESCRIPTION

LVT-1

LUXURY VINYL

TILE

MANUF:

STYLE:

COLOR:

SIZE:

PROVIDE SCHLUTER SCHIENE TRANSITION

AT ALL LVT TO CARPET FLOOR

TRANSITIONS, HEIGHT TO MATCH LVT.

MANUF:

COLOR:

FINISH:

PL-1

PLASTIC

LAMINATE

MANUF:

STYLE:

COLOR:

SS-1

SOLID

SURFACE

QUARTZ

FLOOR

BASE

WALL

PT-2

ACCENT

PAINT

JOHNSONITE

WHITE, 50

COVE

4"

SHAW LVT

GRAIN 0364V

ASHEN, 64155

7" X 48"

SHERWIN WILLIAMS

SKI SLOPE, SW 6518

EGGSHELL @ WALLS

FORMICA

464-G

GRAYSTONE, GLOSS FINISH

SHAW CONTRACT GROUP

NO RULES, SHAPE

GAZE

24" X 24"

CPT-1

CARPET TILE

F I N I S H S Y M B O L K E Y

IDENTIFIES FINISHES THAT

ARE USED MONOLITHICALLY

IN THE ROOM OR AREA

MANUF:

COLOR:

FINISH:

SHERWIN WILLIAMS

INDIGO, SW6531

EGGSHELL @ WALLS

MANUF:

STYLE:

COLOR:

WILSONART

Q1005

ARLINGTON

PROVIDE AT ALL CABINETS

PROVIDE AT ALL COUNTERTOPS AND

BACKSPLASHES

INSTALL LINEAR DIRECTION OF TILE TO

RUN NORTH/SOUTH AS INDICATED ON PLAN

INSTALLATION METHOD BY TENANT

IDENTIFIES LINEAR

DIRECTION OF FLOORING

MATERIAL

CLASS/

RATING

CLASS 1

CLASS 1

CLASS 1

CLASS A

CONFIRM DOOR FRAME PAINT COLOR WITH TENANT.19.

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

1735

07/21/17

CC/JL

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

IS

SU

ED

F

OR

P

ER

MIT

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

A1.5

FINISH PLAN

Page 7: PHOENIX MARKETING INTERNATIONAL€¦ · l i f e s a f e t y p l a n - k e y e d n o t e s l i f e s a f e t y p l a n - legend exit sign existing area not in contract existing non-rated

NON-RATED METAL STUD AND DRYWALL ASSEMBLY FROM

SLAB TO UNDERSIDE OF DECK ABOVE

BASE AS SCHEDULED

METAL STUD CHANNEL

(1) LAYER 5/8" GWB EACH

SIDE

METAL STUD CHANNEL

SLAB TO SLAB NON-RATED INSULATED PARTITION

3-5/8" 25 GA. METAL

STUDS @ 24" O.C.

ACOUSTICAL TILE

CEILING

UNDERSIDE OF DECK

ABOVE

BATT INSULATION,

FRICTION FIT INTO CAVITY

1. PARTITIONS SHALL BE SECURELY FASTENED AT TOP,

BOTTOM AND TERMINATIONS IN ACCORDANCE WITH

THE FLORIDA BUILDING CODE. THE FOLLOWING ARE

MINIMUM REQUIREMENTS - CONTRACTOR SHALL USE

ADDITIONAL FASTENERS AS REQUIRED BY

CONDITIONS ENCOUNTERED IN THE FIELD.

2. WHERE ATTACHING TO CONCRETE SLABS, USE TWO

(2) .145" DIAMETER POWDER-DRIVEN FASTENERS AT

24" O.C. MIN.

3. WHERE ATTACHING TO WOOD SHEATHING OR

BLOCKING, USE TWO (2) NO. 12-14 SCREWS AT 24" O.C.

PARTITION FASTENING NOTES

12

NON-RATED METAL STUD AND DRYWALL ASSEMBLY FROM

SLAB TO CEILING.

BASE AS SCHEDULED

METAL STUD CHANNEL

(1) LAYER 5/8" GWB EACH

SIDE

METAL TOP TRACK ATTACHED

TO CEILING GRID SYSTEM

WITH METAL FASTENERS

SLAB TO CEILING NON-RATED PARTITION

3-5/8" 25 GA. METAL

STUDS @ 24" O.C.

ACOUSTICAL TILE

CEILING

UNDERSIDE OF DECK ABOVE

BRACE PARTITION TO UNDERSIDE OF

DECK ABOVE AT LOCATIONS WHERE

UPPER MILLWORK OR EQUIPMENT IS

SCHEDULED TO BE INSTALLED ON

PARTITION.

NON-RATED METAL STUD AND DRYWALL ASSEMBLY SLAB

TO 4" ABOVE ACOUSTICAL CEILING SYSTEM.

BASE AS SCHEDULED

METAL STUD CHANNEL

(1) LAYER 5/8" GWB EACH

SIDE

METAL STUD CHANNEL

SLAB TO ABOVE CEILING, NON-RATED, INSULATED PARTITION

3-5/8" 25 GA. METAL

STUDS @ 24" O.C.

UNDERSIDE OF DECK ABOVE

MTL BRACING AS REQUIRED

CEILING AS SCHEDULED

BATT INSULATION,

FRICTION FIT INTO CAVITY

3

A

3'-0"

1/2" CLEAR TEMPERED

GLASS PANELS

1/A

2.1

2/A

2.1

8'-0" V

.I.F

.

1/2" CLEAR TEMPERED

GLASS DOOR

METAL PULLS, BOTH

SIDES, BRUSHED AL

FINISH

CONFIRM # OF GLASS PANELS AND SIZE WITH EXISTING

CONDITIONS IN FIELD. MAX GLASS WIDTH 4'-0".

GLASS PANEL SIZE VARIES. PANELS TO BE EQUAL WIDTHS

AT EACH CONDITION, VERIFY IN FIELD.

PROVIDE COPOLYMER STRIPS BY C.R. LAURENCE BETWEEN

GLASS PANELS.

PROVIDE SHOP DRAWINGS TO BUILDING MANAGEMENT FOR

REVIEW AND APPROVAL PRIOR TO ORDERING MATERIALS.

1.

NOTES:

2.

3.

9'-0"

4.

9'-0" A.F.F.

V.I.F.

EXISTING DECK

CONTINUOUS

CORNER BEAD TYP.

3/8" CLEAR TEMPERED

GLAZING IN RECESSED ALUM.

CHANNEL

WOOD BLOCKING

RECESSED ALUM.

CHANNEL

8'-0" A.F.F.

SCREW-ATTACH PARTITION

TO DECK ABOVE WITH (2)

POWDER-DRIVEN

FASTENERS AT 16" O.C.

3 5/8" 25 GA. MTL

STUDS @ 16" O.C.

MTL TRACK TO MATCH

STUD GAUGE AND WIDTH

PROVIDE 3 5/8" MTL STUD

DIAGONAL BRACING AT 16"

O.C.

(7) EQ. DOORS

A2.1

7

REFRIGERATOR

BY TENANT

ALIG

N

*2'-5"

PROVIDE CUT-OUT AT

BACK OF CABINET TO

WALL-MOUNTED

RECEPTACLE

*2'-11" ON

ANGLE-VIF

(3) EQ.

DOORS

*VERIFY APPLIANCE DIMENSIONS PRIOR TO FABRICATION

OF MILLWORK. ALLOW CLEARANCE FOR REFRIGERATOR

DOOR TO FULLY OPEN.

11'-8" ON ANGLE-VIF

FINISHED END

PANEL

FINISHED END

PANEL

A2.1

6

A2.1

5

2'-6"

(3) EQ.

DOORS

COUNTERTOP TO

EXTEND TO WALL

LINE OF WALL AT

CORNER

4" H. BACKSPLASH (SS-1)

1/4" MDF BACK PANEL WITH CUT OUT TO RIGHT

SIDE OF SHELF FOR ELECTRICAL RECEPTACLE

PLASTIC LAMINATE FINISH (PL-1)

3/4" MDF DOOR ON CONCEALED

EUROPEAN STYLE HINGES, PLASTIC

LAMINATE FINISH (PL-1)

ALL INTERIOR SURFACES TO BE MELAMINE,

TYP.

1 X 3 NAILERS, TYP.

2X FIRE RETARDANT TREATED

WOOD BLOCKING AS REQUIRED

FOR SUPPORT OF CABINETS, TYP.

PARTITION AS SCHEDULED

CEILING AS SCHEDULED

1'-8"

ALL INTERIOR SURFACES OF MICROWAVE

SHELF/OPENING TO BE PLASTIC LAMINATE

FINISH (PL-1)

2'-10"

2'-0"

SINK AND FAUCET - REFER TO M.E.P.

DRAWINGS FOR SPECIFICATIONS

3/4" MDF FIXED PANEL, PLASTIC

LAMINATE FINISH (PL-1)

3/4" MDF TOE KICK FACE, PLASTIC

LAMINATE FINISH (PL-1)

1/4" MDF BACK, MELAMINE FINISH

1/2" THICK COUNTERTOP (SS-1).

COORDINATE SUBSTRATE WITH

MILLWORK SUB-CONTRACTOR.

3/4" MDF DOOR ON CONCEALED EUROPEAN

STYLE HINGES, PLASTIC LAMINATE FINISH

(PL-1)

BRACING AND SUPPORT UNDER CABINET

BASE AND BEHIND TOE KICK FACE AS

REQUIRED

4" H. BACKSPLASH (SS-1)

3/4" MDF DOOR ON CONCEALED

EUROPEAN STYLE HINGES, PLASTIC

LAMINATE FINISH (PL-1)

1/4" MDF BACK, MELAMINE FINISH

ALL INTERIOR SURFACES TO BE MELAMINE,

TYP.

(1) ADJUSTABLE 3/4" MDF SHELF,

MELAMINE FINISH - LINE-BORE

ADJUSTMENT HOLES 1" O.C. AND PROVIDE

HEAVY DUTY SHELF CLIPS

1 X 3 NAILERS, TYP.

2X FIRE RETARDANT TREATED WOOD

BLOCKING AS REQUIRED FOR

SUPPORT OF CABINETS, TYP.

PARTITION AS SCHEDULED

CEILING AS SCHEDULED

2'-1"

2'-0"

3"

4"

1 1/2"

6"

MIN

.

1'-0"

CLEAR

2'-6"

10"

8 1/2"

4"

2'-10"

1/2" THICK COUNTERTOP (SS-1).

COORDINATE SUBSTRATE WITH

MILLWORK SUB-CONTRACTOR.

8 1/2"

2'-0"

4" H. BACKSPLASH (SS-1)

2'-1"

3/4" MDF DOOR ON CONCEALED

EUROPEAN STYLE HINGES, PLASTIC

LAMINATE FINISH (PL-1)

1/4" MDF BACK, MELAMINE FINISH

ALL INTERIOR SURFACES TO BE MELAMINE,

TYP.

(1) ADJUSTABLE 3/4" MDF SHELF,

MELAMINE FINISH - LINE-BORE

ADJUSTMENT HOLES 1" O.C. AND

PROVIDE HEAVY DUTY SHELF CLIPS

1 X 3 NAILERS, TYP.

2X FIRE RETARDANT TREATED

WOOD BLOCKING AS REQUIRED

FOR SUPPORT OF CABINETS, TYP.

10"

4"

6"

1'-0"

3/4" MDF TOE KICK FACE, PLASTIC

LAMINATE FINISH (PL-1)

1/4" MDF BACK, MELAMINE FINISH

3/4" MDF DOOR ON CONCEALED

EUROPEAN STYLE HINGES, PLASTIC

LAMINATE FINISH (PL-1)

BRACING AND SUPPORT UNDER

CABINET BASE AND BEHIND TOE KICK

FACE AS REQUIRED

3/4" MDF DRAWER WITH PLASTIC LAMINATE

EXTERIOR FINISH (PL-2) AND MELAMINE

INTERIOR FINISH, ON FULL EXTENSION

GLIDES, TYP.

(1) ADJUSTABLE 3/4" MDF SHELF, MELAMINE

FINISH - LINE-BORE ADJUSTMENT HOLES 1"

O.C. AND PROVIDE HEAVY DUTY SHELF

CLIPS

CABINET PULL, TYP.

PARTITION AS SCHEDULED

CEILING AS SCHEDULED

2'-0"

3"

1 1/2"

6"

MIN

.

1'-0"

CLEAR

2'-6"

4"

1'-2"

2'-10"

1/2" THICK COUNTERTOP (SS-1). COORDINATE

SUBSTRATE WITH MILLWORK

SUB-CONTRACTOR.

2'-1"

1'-8"

1'-8"

CABINET PULL, TYP.

CABINET PULL, TYP.

CABINET PULL, TYP.

CABINET PULL, TYP.

2'-0"

4"

6"

1'-0"

3/4" MDF TOE KICK FACE, PLASTIC

LAMINATE FINISH (PL-1)

1/4" MDF BACK, MELAMINE FINISH

3/4" MDF DOOR ON CONCEALED

EUROPEAN STYLE HINGES, PLASTIC

LAMINATE FINISH (PL-1)

BRACING AND SUPPORT UNDER

CABINET BASE AND BEHIND TOE KICK

FACE AS REQUIRED

3/4" MDF DRAWER WITH PLASTIC LAMINATE

EXTERIOR FINISH PL-2 AND MELAMINE

INTERIOR FINISH, ON FULL EXTENSION

GLIDES, TYP.

(1) ADJUSTABLE 3/4" MDF SHELF, MELAMINE

FINISH - LINE-BORE ADJUSTMENT HOLES 1"

O.C. AND PROVIDE HEAVY DUTY SHELF

CLIPS

CABINET PULL, TYP.

3"

1 1/2"

MIN

.

4"

1'-0"

CLEAR

PROVIDE 1" RADIUS EDGE AT FRONT CORNERS

OF PLASTIC LAMINATE SHELF, FINISH PL-1

LINE OF CABINET BEYOND

CONTRACTOR SHALL SUBMIT (2) SETS OF SHOP DRAWINGS

TO BUILDING MANAGEMENT FOR APPROVAL PRIOR TO

COMMENCEMENT OF WORK OR ORDERING OF ANY

MATERIALS.

MILLWORK GENERAL NOTES

ALL HINGES SHALL BE MIN. 110° CONCEALED EUROPEAN

STYLE. ALL DRAWER SLIDES SHALL BE FULL EXTENSION.

ALL HARDWARE SHALL BE PROVIDED AND INSTALLED BY

CONTRACTOR, UNLESS OTHERWISE NOTED.

ALL CABINETRY SHALL BE FLUSH OVERLAY STYLE.

ALL MILLWORK SHALL BE BUILT AND INSTALLED IN

ACCORDANCE WITH CUSTOM GRADE PER ARCHITECTURAL

WOODWORK INSTITUTE (AWI) QUALITY STANDARDS.

ALL INTERIOR SURFACES SHALL BE WHITE MELAMINE,

UNLESS OTHERWISE NOTED.

A.

B.

C.

D.

E.

F.

CONTRACTOR TO CONFIRM EXACT SPECIFICATION OF

CABINET PULL WITH BUILDING MANAGEMENT AND

TENANT.

G.

CONTINUOUS

CORNER BEAD TYP.

3/8" CLEAR TEMPERED

GLAZING IN RECESSED ALUM.

CHANNEL

WOOD BLOCKING

RECESSED ALUM.

CHANNEL

1"

GLAZING AS

SCHEDULED

1" ALUM. "C"

CHANNEL

**USE WHITE GASKET

@ ALL ALUM. GLASS

TRACKS**

B

2/A

2.1

SIM

.

3'-6"

3/A

2.1

8'-0" V

.I.F

.

3/8" CLEAR TEMPERED

GLASS PANELS WITH

CLEAR SILICONE

SEALANT

10"

DOOR AS

SCHEDULED

VARIES

V.I.F.

9'-0"

GLASS PANEL SIZE VARIES. CONFIRM WITH CONDITIONS IN

FIELD.

PROVIDE SHOP DRAWINGS TO BUILDING MANAGEMENT FOR

REVIEW AND APPROVAL PRIOR TO ORDERING MATERIALS.

1.

NOTES:

2.

ALIGN

IS

SU

ED

F

OR

P

ER

MIT

A2.1

PARTITION TYPES, ELEVATIONS &

DETAILS

PARTITION TYPES (1" = 1'-0")

GLAZING DETAIL - SILL

A2.1

2

3" = 1'-0"

GLAZING DETAILS

GLAZING DETAIL - HEAD

A2.1

3

3" = 1'-0"

GLAZING DETAIL - SILL

A2.1

1

3" = 1'-0"

ELEVATION - BREAK

A2.1

4

3/8" = 1'-0"

SECTION - SINK CABINET

A2.1

5

3/4" = 1'-0"

SECTION - DRAWER CABINET

A2.1

6

3/4" = 1'-0"

SECTION - MICROWAVE CABINET

A2.1

7

3/4" = 1'-0"

S H E E T N O.

S H E E T T I T L E

J O B N O.

I S S U E D A T E:

D R A W N B Y:

NO. REVISIONS DATE

Drawing Not Valid Unless Signed,

Sealed & Dated By Registered Professional

1735

07/21/17

CC

SCALE: 1/8" = 1'-0"

0 1' 5' 10'

6822 22nd Ave. N. #148St. Petersburg, Florida 33710

Ph: 727.515.8461

Planning & Design of the Built Environment

FL. LIC. NO.: AA26002603

CMK Design Studio, Inc.

IN

TE

RIO

R R

EN

OV

AT

IO

N

PH

OE

NIX

M

AR

KE

TIN

G IN

TE

RN

AT

IO

NA

L

TA

MP

A, F

LO

RID

A 3

36

02

40

0 N

A

SH

LE

Y D

RIV

E, S

UIT

E 1

97

5

WINDOW TYPES (3/8" = 1'-0")