ELEVATOR
LOBBY
MEN
WOMEN
STAIRS
NORTH
PUBLIC
CORRIDOR
SOUTH
PUBLIC
CORRIDOR
STAIRS
FREIGHT
ELEVATOR
ELEC.
FREIGHT
ELEVATOR
OFC/
HUDDLE
1906
CALL
CENTER
1903
ENTRY
1900
WORK RM
1901
BREAK
1908
CONFERENCE
1905
OPEN
WORK AREA
1904
MAX. ALLOWED
100'-0"
COMMON PATH
OF TRAVEL 92'-4"
LS-1
EXIT
EXIT TRAVEL
DISTANCE: 95'-7"
MAX. ALLOWED
300'-0"
315 NET S.F.
FE
COLLABORATION
1907
IT
1902
EXIT TRAVEL
DISTANCE: 151'-2"
MAX. ALLOWED
300'-0"
L I F E S A F E T Y P L A N - K E Y E D N O T E S
L I F E S A F E T Y P L A N - LEGEND
EXIT SIGN
EXISTING AREA NOT IN CONTRACT
EXISTING NON-RATED TENANT SEPARATION PARTITION TO REMAIN
NEW NON-RATED, SLAB TO SLAB PARTITION
NEW NON-RATED, SLAB TO CEILING PARTITION
EXISTING NON-RATED PARTITION TO REMAIN
CONSTRUCTION TYPE
OCCUPANCY TYPE
CODES/GUIDELINES
BUILDING INFORMATION
BUSINESS, GROUP B
FLOOR AREA2,500 S.F. LOCATION: 19th FLOOR
OCCUPANT LOAD
EGRESS
FLORIDA BUILDING CODE, 5TH EDITION (2014)
FLORIDA ACCESSIBILITY CODE, 5TH EDITION (2014)
FLORIDA PLUMBING CODE, 5TH EDITION (2014)
FLORIDA MECHANICAL CODE, 5TH EDITION (2014)
NATIONAL ELECTRIC CODE, 2011 EDITION
FLORIDA FIRE PREVENTION CODE
NFPA 101: LIFE SAFETY CODE, 2012 EDITION
NFPA 72: FIRE ALARM, 2010 EDITION
TYPE I-B, SPRINKLERED 32-STORY BUILDING
STAIR WIDTH REQUIRED: .3 INCHES PER OCCUPANT = 12.9"
PROVIDED: 84" (2 STAIRS TOTAL)
BUSINESS - 100 SF/OCCUPANT; 2,185 SF = 22 PEOPLE
**ASSEMBLY - 15 SF/OCCUPANT; 315 SF = 21 PEOPLE
43 TOTAL PEOPLE
**ASSEMBLY AREA TO HAVE TABLE AND CHAIRS, LAYOUT BY
TENANT
FUNCTION OF SPACE
LS-1 NEW FIRE EXTINGUISHER MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS
OF N.F.P.A. 10.
PHOENIX MARKETING
INTERNATIONAL
400 N ASHLEY DRIVE, SUITE 1975
TAMPA, FLORIDA 33602
ARCHITECTURAL DRAWINGS ENGINEERING DRAWINGS
CONSTRUCTION PLANA1.2
REFLECTED CEILING PLANA1.3
POWER PLANA1.4
PARTITION TYPES,
ELEVATIONS & DETAILS
A2.1
DIAMONDBACK ENGINEERING
1801 N. HIMES AVE.
TAMPA, FL 33607
813.517.8254
MECHANICAL PLANM1
ELECTRICAL SYMBOL LEGEND AND
GENERAL NOTES
E1
FIRE PROTECTION PLANFP1
COVER SHEET/LIFE
SAFETY PLAN
A1.0
DEMOLITION PLANA1.1
ELECTRICAL DEMOLITION PLANE2
LIGHTING PLANE3
POWER & MISC. SYSTEMS PLANE4
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
1735
07/21/17
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
CC/JL
A1.0
COVER SHEET/LIFE SAFETY PLAN
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
IS
SU
ED
F
OR
P
ER
MIT
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
FINISH PLANA1.5
PLUMBING PLANP1
PLUMBING LISTP2
ELECTRICAL PANEL SCHEDULES
AND POWER ONE-LINE DIAGRAM
E5
ELEVATOR
LOBBY
MEN
WOMEN
STAIRS
NORTH
PUBLIC
CORRIDOR
SOUTH
PUBLIC
CORRIDOR
STAIRS
FREIGHT
ELEVATOR
ELEC.
FREIGHT
ELEVATOR
J
E
,
8
2
"
D1
D2
D3
PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY DEMOLITION OR NEW CONSTRUCTION WITH
MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS, AND PROVIDE A UNIFORM, SMOOTH SURFACE.
PREPARE GYPSUM BOARD SURFACES THROUGHOUT TO RECEIVE NEW WALL FINISHES (TO CEILING HEIGHT)
AS SPECIFIED.
ALL ITEMS DASHED ON PLANS ARE EXISTING CONDITIONS TO BE REMOVED. ALL OTHER ITEMS SHOWN ARE
EXISTING CONDITIONS TO REMAIN INSTALLED AND OPERATIONAL.
D E M O L I T I O N P L A N - G E N E R A L N O T E S
2.
1.
D E M O L I T I O N P L A N - K E Y E D N O T E S
D1
P A R T I T I O N L E G E N D
REMOVE ALL VINYL/RUBBER BASE THROUGHOUT AREA OF WORK, UNLESS OTHERWISE NOTED. PATCH AND
REPAIR ALL SURFACES AND OBJECTS AFFECTED BY DEMOLITION AS REQUIRED TO PROVIDE A UNIFORM,
SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES. FLOAT SLAB AS NECESSARY TO MEET TOLERANCE
REQUIREMENTS OF A.C.I. STANDARDS FOR CLASS A OFFICE BUILDINGS (
1
8
" IN 10') TO ACHIEVE A LEVEL
SURFACE FOR THE INSTALLATION OF NEW FLOOR COVERING MATERIALS. CONTRACTOR TO SURVEY
CONDITION OF FLOOR PRIOR TO PROVIDING BID OR STARTING ANY WORK.
D E M O L I T I O N L E G E N D
DISCONNECT FROM SOURCE AND REMOVE EXISTING JUNCTION BOX FROM THIS LOCATION.
PATCH AND REPAIR WALL AS REQUIRED TO PROVIDE A UNIFORM, SMOOTH SURFACE FOR THE
RECEIPT OF NEW FINISHES.
EXISTING NON-RATED PARTITION TO REMAIN INSTALLED
EXISTING AREA NOT IN CONTRACT
J
JUNCTION BOX TO BE REMOVED.
REMOVE ALL EXISTING CEILING TILES, LIGHT FIXTURES, EXIT LIGHTS, CEILING FANS, AND CEILING DEVICES
THROUGHOUT AREA OF WORK (REFER TO REFLECTED CEILING PLAN FOR EXACT EXTENTS). ALL EXISTING
CEILING GRID IS TO REMAIN.
D2
D3
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
1735
07/21/17
CC/JL
A1.1
DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
IS
SU
ED
F
OR
P
ER
MIT
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
ELEVATOR
LOBBY
MEN
WOMEN
STAIRS
NORTH
PUBLIC
CORRIDOR
SOUTH
PUBLIC
CORRIDOR
STAIRS
FREIGHT
ELEVATOR
ELEC.
FREIGHT
ELEVATOR
E
1
3
3
2
3
3
FE
A2.1
4
A
A
B
9'-8 1/2"
1
4
'-
0
"
1
2
1
7
'
-
0
"
7'-0"
5
'
-
0
"
1
3
2 2
1
1
B
B
B
3
1
4
'-
1
1
"
ALIGN
C2
C1
C4
C5
C6
6'-6" 5'-8"
3
ALIGNALIGN
ALIGN
16'-10"
C7
C8
C9
A
L
I
G
N
ALIG
N
A
L
IG
N
A
L
IG
N
A
L
I
G
N
5
'-
4
"
ALIG
N
ALIGN
8
'-
2
"
4'-9"
4'-9"
C3
SIM.
SIM.
3
3
3
SIM.
3
3
'
-
3
"
1
1
'
-
0
"
7"
3
'-
0
"
1
0
"
PROVIDE AND INSTALL NEW PHONE BOARD - 4'W X 8'H X 5/8" TH. FIRE RETARDANT
TREATED PLYWOOD, SKIM COATED, SANDED AND PAINTED WITH (2) COATS OF FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL. COORDINATE WITH TENANT FOR
EXACT MOUNTING HEIGHT AND LOCATION.
FURNISH AND INSTALL NEW BUILDING STANDARD SURFACE MOUNTED FIRE EXTINGUISHER
AT THIS LOCATION, MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS OF
N.F.P.A. 10. SECURELY FASTEN MOUNTING BRACKETS TO BLOCKING, SQUARE AND PLUMB,
TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
P A R T I T I O N L E G E N D
C O N S T R U C T I O N P L A N - K E Y E D N O T E S
C1
PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY THE REMOVAL OF
POWER, TELE/DATA RECEPTACLE, SWITCH OR JUNCTION BOX AS REQUIRED TO
PROVIDE A UNIFORM, SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.
PROVIDE AND INSTALL NEW BUILDING STANDARD SINGLE BOWL, STAINLESS STEEL,
UNDERMOUNT SINK WITH ADA COMPLIANT FAUCET. COORDINATE WITH MILLWORK
CONTRACTOR AND VERIFY IN FIELD EXACT INSTALLATION LOCATION PRIOR TO THE
EXECUTION OF ANY WORK. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.
PROVIDE AND INSTALL NEW IN-LINE WATER HEATER. COORDINATE WITH MILLWORK
CONTRACTOR AND VERIFY IN FIELD EXACT INSTALLATION LOCATION PRIOR TO THE
EXECUTION OF ANY WORK. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.
PROVIDE AND INSTALL COLD WATER LINE FOR TENANT PROVIDED, CONTRACTOR
INSTALLED REFRIGERATOR. COORDINATE WITH MILLWORK CONTRACTOR AND VERIFY
IN FIELD EXACT INSTALLATION LOCATION PRIOR TO THE EXECUTION OF ANY WORK.
REFER TO M.E.P. DOCUMENTS FOR FURTHER INFORMATION.
C O N S T R U C T I O N P L A N - G E N E R A L N O T E S
1.ALL LABOR, MATERIALS, FINISH REQUIREMENTS, AND THE FINAL FINISHED PRODUCT AS
OUTLINED AND REQUIRED BY THE PLANS, SPECIFICATIONS AND OTHER CONTRACT
DOCUMENTS, SHALL CONFORM WITH THE CURRENT STANDARD EDITION OF THE LOCAL CODES
AND REQUIREMENTS.
ALL DIMENSIONS SHOWN ON PLANS ARE FROM FINISHED FACE OF PARTITION TO FINISHED
FACE OF PARTITION, UNLESS OTHERWISE NOTED.
DISCREPANCIES BETWEEN ARCHITECTURAL AND ENGINEERING DOCUMENTS ARE TO BE
BROUGHT TO THE ATTENTION OF THE TENANT AND DESIGNER IMMEDIATELY UPON DISCOVERY.
SUBMIT IN WRITING TO THE TENANT AND DESIGNER THE NATURE OF THE CONFLICT, THE SHEET
NUMBERS, AND THE SPECIFIC ITEMS FOUND TO BE IN CONFLICT. NOTIFICATION OF CONFLICT
MUST BE REPORTED PRIOR TO SUBMISSION OF BID AND COMMENCEMENT OF WORK.
7.
6.
5.
ALL WORK AND FINISHED EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT SATISFACTORY
TO THE BUILDING MANAGEMENT, TENANT AND DESIGNER.
INSTALL FIRE EXTINGUISHER(S) MOUNTED AND LOCATED TO COMPLY WITH THE REQUIREMENTS
AS SET FORTH IN THE CURRENT STANDARD EDITION OF NFPA-10.
CONTRACTOR WILL SECURE ALL BUILDING PERMITS & INSPECTIONS NECESSARY FOR THE
CONSTRUCTION OF THE SPACE.
4.
3.
MAINTENANCE EXCLUSION: THESE DRAWINGS WERE PREPARED FOR PURPOSES OF
CONSTRUCTION ONLY. THESE DRAWINGS ARE NOT TO BE USED FOR MAINTENANCE PURPOSES
AS ACTUAL CONDITIONS MAY VARY FROM THOSE SHOWN ON THE DRAWINGS DUE TO CHANGE
ORDERS, ALTERATIONS BY OTHERS, FIELD CONDITIONS, ETC.
THE TENANT'S WRITTEN AUTHORIZATION MUST BE OBTAINED PRIOR TO THE ORDERING OF ANY
MATERIAL, AWARDING OF ANY CONTRACTS, OR THE EXECUTION OF ANY WORK INVOLVING
EXTRA COST TO THE CONTRACT SUM.
DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.
IF ANY ADDITIONAL WORK OR CHANGES WILL ADVERSELY AFFECT THE COMPLETION
SCHEDULE, THE CONTRACTOR SHALL ADVISE THE TENANT AND DESIGNER IN WRITING OF SUCH
DELAY.
19.
14.
13.
PLANS WERE DEVELOPED FROM INFORMATION SUPPLIED BY THE BUILDING MANAGEMENT AND
EXISTING CONDITIONS OBSERVED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD PRIOR TO COMMENCING ANY WORK. ANY DISCREPANCIES BETWEEN
DRAWINGS AND EXISTING CONDITIONS ARE TO BE REPORTED TO THE TENANT, DESIGNER AND
BUILDING MANAGEMENT IN WRITING PRIOR TO STARTING WORK ON A GIVEN ITEM AND BEFORE
INCURRING ANY ADDITIONAL COST.
8.
2.
9.
10.
11.
12.
ALL SPRINKLERS, EITHER EXISTING TO REMAIN, REMOVED AND RELOCATED, AND/OR NEW, ARE
TO COMPLY WITH THE REQUIREMENTS AS SET FORTH IN THE CURRENT STANDARD EDITION OF
NFPA-13.
CONTRACTOR SHALL COORDINATE ALL WOOD BLOCKING, STEEL SUPPORTS AND ANY OTHER
ITEMS WHICH ARE IMBEDDED IN DRYWALL PARTITIONS OR ENCLOSURES WHICH RELATE TO HIS
WORK OR THE WORK OF ANY SEPARATE CONTRACTORS. ALL WOOD BLOCKING, BRIDGING,
BRACING, FRAMING, ETC., SHALL BE FIRE RETARDANT AS CALLED FOR BY THE BUILDING CODE
AND THE CONTRACTOR MUST SUBMIT AFFIDAVITS OF SUCH FIRE RETARDATION TO THE
DESIGNER.
CONTRACTOR TO PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY DEMOLITION
OR NEW CONSTRUCTION WITH MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS
AND TO PROVIDE A UNIFORM NEW CONDITION. PREPARE GYPSUM BOARD WALLS (TO CEILING
HEIGHT) AND ALL OTHER GYPSUM BOARD SURFACES THROUGHOUT TO ACHIEVE A UNIFORM,
SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.
20.
CONTRACTOR TO FIELD SURVEY CONDITION OF EXISTING FLOOR SLAB. PLUG, REPAIR AND
FLOAT SLAB AS NECESSARY TO MEET TOLERANCE REQUIREMENTS OF A.C.I. STANDARDS FOR
CLASS A OFFICE BUILDINGS (1/8" IN 10' ) AND TO ACHIEVE A LEVEL SURFACE FOR THE
INSTALLATION OF NEW FLOOR COVERING MATERIALS.
CONTRACTOR TO SURVEY CONDITION OF EXISTING EXTERIOR WINDOW WALL, KNEE WALL AND
PERIMETER SPANDREL PANELS. PATCH & REPAIR AS NECESSARY WITH MATERIALS AND
METHODS TO MATCH EXISTING CONDITIONS AND TO ACHIEVE A UNIFORM, SMOOTH SURFACE
FOR THE RECEIPT OF NEW FINISHES.
CONTRACTOR TO SURVEY CONDITION OF CORE WALL AND COLUMNS. PATCH & REPAIR AS
NECESSARY WITH MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS AND TO
ACHIEVE A UNIFORM, SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.
CONTRACTOR TO FURR-OUT WALLS, COLUMNS, KNEE WALLS AND PERIMETER SPANDREL
PANELS AS NECESSARY TO ACCOMMODATE NEW DEVICES AND/ OR EQUIPMENT AS SPECIFIED.
15.
16.
17.
18.
CONTRACTOR TO SURVEY CONDITIONS OF BUILDING STANDARD WINDOW TREATMENTS ON ALL
EXTERIOR WINDOWS. REPAIR OR REPLACE WINDOW TREATMENTS AS NECESSARY TO ACHIEVE
A UNIFORM NEW APPEARANCE AND FUNCTION. VERIFY WITH BUILDING MANAGEMENT FOR
BUILDING STANDARD WINDOW TREATMENT SPECIFICATIONS.
EXISTING PARTITION TO REMAIN
NEW SLAB TO CEILING, NON-RATEDPARTITION. SEE PARTITION TYPE 2, SHEET A2.1.
1
2
EXISTING TENANT SEPARATION TO REMAIN
EXISTING AREA NOT IN CONTRACT
NEW SLAB TO SLAB, NON-RATED PARTITION WITH INSULATION. SEE PARTITION
TYPE 1, SHEET A2.1.
ALL INTERIOR FINISHES ARE TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING
CODE - 5TH EDITION, CHAPTER 8, TABLE 803.9.
C2
CONTRACTOR TO PROVIDE AND INSTALL NEW 24 HOUR SUPPLEMENTAL AIR UNIT THIS
ROOM PER TENANT'S REQUIREMENTS. REFER TO M.E.P. DOCUMENTS FOR FURTHER
INFORMATION.
C3
C4
C5
C6
FOLLOW EXISTING RADIUS TO CONTINUE CURVED PARTITION.
C7
C8
C9
PROVIDE AND INSTALL FIRE RETARDANT WOOD BLOCKING IN WALL TO ACCOMMODATE
TV AND/OR EQUIPMENT. COORDINATE EXACT LOCATION/EXTENTS WITH EQUIPMENT
SPECIFICATIONS AND TENANT'S A/V VENDOR.
NEW SLAB TO ABOVE CEILING, NON-RATEDPARTITION. SEE PARTITION TYPE 3,
SHEET A2.1.
3
D O O R S C H E D U L E
1
NEW BUILDING STANDARD DOOR ASSEMBLY:
PROVIDE AND INSTALL NEW 3'-0" WIDE, SOLID CORE, STAIN GRADE
WOOD DOOR, FRAME, HARDWARE AND DOOR STOP TO MATCH BUILDING
STANDARD. PROVIDE CLASSROOM FUNCTION HARDWARE.
2
D O O R G E N E R A L N O T E S
HOLD ALL NEW DOORS 6" OFF THE HINGE SIDE WALL, UNLESS
OTHERWISE NOTED.
ALL HARDWARE MUST BE ADA COMPLIANT.
ALL LOCKS TO BE MASTER-KEYED TO BUILDING STANDARD SYSTEM.
SEE CHIEF BUILDING ENGINEER TO COORDINATE.
ALL HARDWARE FINISH MUST BE BUILDING STANDARD, UNLESS
OTHERWISE NOTED.
4.
3.
1.
2.
5.LOCK FUNCTION DEFINITIONS:
a. Passage Function: Both levers always unlocked.
Classroom Function: Outside lever locked and unlocked by key. Inside
lever always unlocked.
b.
NEW BUILDING STANDARD DOOR ASSEMBLY:
PROVIDE AND INSTALL NEW 3'-0" WIDE, SOLID CORE, STAIN GRADE
WOOD DOOR, FRAME, HARDWARE AND DOOR STOP TO MATCH
BUILDING STANDARD. PROVIDE PASSAGE FUNCTION HARDWARE.
EXISTING BUILDING STANDARD DOUBLE DOOR ASSEMBLY:
PROTECT FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.
E
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
1735
07/21/17
CC/JL
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
IS
SU
ED
F
OR
P
ER
MIT
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
A1.2
CONSTRUCTIONPLAN
ELEVATOR
LOBBY
MEN
WOMEN
STAIRS
NORTH
PUBLIC
CORRIDOR
SOUTH
PUBLIC
CORRIDOR
STAIRS
FREIGHT
ELEVATOR
ELEC.
FREIGHT
ELEVATOR
N
N
N
N
N
N
N
N
N
N
N
N
N N N
N N N
N
N
N
N N
N
N N
N
N
N
N
N NN
N NN
N
N
N
N
N
N
N
N
N
N
EMERGENCY EXIT LIGHT
BUILDING STANDARD WALL SWITCH, MOUNTED AT 48" A.F.F. TO CENTER OF
SWITCHPLATE (UNLESS OTHERWISE NOTED).
R E F L E C T E D C E I L I N G P L A N - L E G E N D
FIRE SPRINKLERS LOCATED AND INSTALLED THROUGHOUT THE TENANT SPACE SHALL CONFORM WITH THE
REQUIREMENTS OF N.F.P.A.-13. ALL SPRINKLERS TO BE REMOVED, RELOCATED AND/ OR ADDED ARE TO BE
CENTERED IN THE CEILING TILE. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.
COORDINATE WITH TENANT'S SECURITY, CABLING AND AUDIO VISUAL VENDORS FOR COMPLETION OF WORK
PRIOR TO CLOSING UP CEILING.
5.
R E F L E C T E D C E I L I N G P L A N - G E N E R A L N O T E S
INSTALL SMOKE DETECTION DEVICES TO COMPLY WITH ALL CODE REQUIREMENTS. VERIFY IN FIELD WITH
BUILDING MANAGEMENT FOR BUILDING STANDARD DEVICES TO BE USED AND PROCEDURES TO CONNECT TO
BASE BUILDING FIRE ALARM SYSTEM. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.
SUPPLY, INSTALL AND CONNECT ALL EMERGENCY LIGHTING AS PER ALL APPLICABLE CODES AND ORDINANCES.
REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.
2.
4.
1.
MULTIPLE SWITCHES SHOWN AT THE SAME LOCATION ARE TO BE GANGED IN THE SAME SWITCH COVER PLATE.
3.
6.
7.
8.
EXISTING 2'X2' SUSPENDED CEILING GRID SYSTEM. FIELD SURVEY EXISTING GRID
SYSTEM AND ADJUST AS NECESSARY TO MAINTAIN A LEVEL CEILING SURFACE. PROTECT
DURING DEMOLITION AND CONSTRUCTION. REPAIR OR REPLACE CEILING GRID
THROUGHOUT AS NECESSARY TO ACHIEVE A UNIFORM, LIKE NEW APPEARANCE. PROVIDE
AND INSTALL NEW 2'X2' ACOUSTICAL CEILING TILES THROUGHOUT AREA OF WORK.
CEILING TILE TO BE ARMSTRONG, DUNE, WHITE TILE (CLASS A).
RECESSED LED DOWNLIGHT. REFER TO M.E.P. DOCUMENTS FOR SPECIFICATION.
9.
COORDINATE AIR CONDITIONING DUCTWORK ELEVATIONS, BEAM DROPS, PIPING AND ANY OTHER
OBSTRUCTIONS WITH LIGHT FIXTURE DEPTHS AND LOCATIONS TO ASCERTAIN THAT PROPER CLEARANCES CAN
BE MAINTAINED IN ACCORDANCE WITH REQUIRED FINISHED SUSPENDED CEILING HEIGHTS. THIS
COORDINATION SHALL BE DONE BEFORE LIGHT FIXTURES ARE ORDERED AND BEFORE SUSPENDED CEILING
SYSTEM CONSTRUCTION BEGINS. CONTRACTOR SHALL REPORT ANY CONFLICTS OR DISCREPANCIES TO THE
DESIGNER.
ALL NEW SWITCHES AND COVERPLATES SHOWN ARE TO MATCH EXISTING.
2' x 2' FLUORESCENT LIGHT FIXTURE. LIGHT FIXTURES TO BE RELOCATED FROM BUILDING
STOCK. COORDINATE WITH BUILDING MANAGEMENT.
DENOTES EXISTING FIXTURE OR DEVICE TO REMAIN INSTALLED AND OPERATIONAL.
PROTECT DURING DEMOLITION AND CONSTRUCTION.
E
DENOTES EXISTING FIXTURE OR DEVICE SHOWN AT NEW RELOCATED POSITION.R
DENOTES NEW FIXTURE OR DEVICE TO MATCH EXISTING (UNLESS OTHERWISE NOTED)
AND TO BE PROVIDED AND INSTALLED BY CONTRACTOR.
N
WHERE DEMOLITION/ CONSTRUCTION AFFECTS SUSPENDED CEILING SYSTEM, CONTRACTOR SHALL REPLACE
AND/ OR REPAIR EXISTING CEILING GRID AS NECESSARY TO ACHIEVE A UNIFORM, LIKE NEW APPEARANCE.
MATCH NEW CEILING COMPONENTS TO EXISTING ADJACENT CEILING SYSTEM AND ALIGN IN BOTH THE
HORIZONTAL DIMENSION AND THE HEIGHT INSTALLED A.F.F.
EXISTING CEILING CONDITIONS TO REMAIN SHALL BE PROTECTED DURING DEMOLITION AND CONSTRUCTION TO
MAINTAIN ITS EXISTING FINISH CONDITION. CONTRACTOR TO FIELD SURVEY CONDITION OF EXISTING
SUSPENDED ACOUSTICAL CEILING SYSTEM IN THESE AREAS. ADJUST, LEVEL AND RETIE EXISTING CEILING GRID
TO STRUCTURE ABOVE AND/OR REPAIR GRID AS REQUIRED TO MAINTAIN A UNIFORM, LEVEL CEILING SURFACE
AND TO PROVIDE A LIKE NEW APPEARANCE. INSTALL FIXTURES AND DEVICES AS SPECIFIED ON REFLECTED
CEILING PLAN. ALL RELOCATED FIXTURES AND DEVICES ARE TO BE REFURBISHED AND REPAIRED AS
NECESSARY TO ACHIEVE A LIKE NEW APPEARANCE AND FUNCTION. CLEAN AND RE-LAMP ALL FIXTURES AS
NECESSARY TO ACHIEVE A UNIFORM, LEVEL LAMP COLORING AND LIGHT LEVEL.
REFER TO M.E.P. DOCUMENTS FOR ALL LIGHT SWITCHING.
10.
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
1735
07/21/17
CC/JL
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
IS
SU
ED
F
OR
P
ER
MIT
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
A1.3
REFLECTEDCEILING PLAN
ELEVATOR
LOBBY
MEN
WOMEN
STAIRS
NORTH
PUBLIC
CORRIDOR
SOUTH
PUBLIC
CORRIDOR
STAIRS
FREIGHT
ELEVATOR
ELEC.
FREIGHT
ELEVATOR
N
N
,4
4
",G
F
C
I
N
,IH
,G
F
C
I
N
,
M
I
C
,
4
4
"
N
,
4
W
S
N
,
4
W
S
N
,
R
E
F
N
,
4
4
"
,
G
F
C
I
N
N
N
N
N
,
4
W
S
N
,
4
W
S
N
,4
W
S
N
,4
W
S
N
N
N
N
N
N
N
N
N
N
N
N,C
OP
Y
N,C
OP
Y
N
E
E
E
E E E
E
N
N,C
OP
Y
N,C
OP
Y
N
N
N
N
N
N
N
,T
V
,6
6
"
N
N
N
N
P1
P2
P3
P4
CONTRACTOR TO VERIFY REQUIRED NEMA CONFIGURATION FOR ANY NON-STANDARD
RECEPTACLE(S).
EXISTING WIRING AND CONDUIT ABOVE THE CEILING THAT HAS BEEN ABANDONED SHALL BE
DEMOLISHED/ REMOVED.
DUPLEX VOICE/ DATA COMMUNICATION RECEPTACLE, PLUG-IN TYPE, MOUNTED AT 18" A.F.F. TO CENTER
OF RECEPTACLE (UNLESS OTHERWISE NOTED). EXTEND 3/4" EMPTY CONDUIT WITH PULL-STRING TO 6"
ABOVE SUSPENDED CEILING. TERMINATE WITH INSULATING BUSHING.
DUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT 18" A.F.F. TO CENTER OF RECEPTACLE (UNLESS
OTHERWISE NOTED).
P O W E R / C O M M U N I C A T I O N S L E G E N D
CONTRACTOR TO STAGGER RECEPTACLES ON OPPOSITE SIDE OF WALL BY MINIMUM OF ONE STUD
FOR SOUND ATTENUATION (TYP.).
P O W E R / C O M M U N I C A T I O N S - G E N E R A L N O T E S
3.
2.
1.
P1
P O W E R / C O M M U N I C A T I O N S - K E Y E D N O T E S
4.
DEDICATED DUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT 18" A.F.F. TO CENTER OF RECEPTACLE
(UNLESS OTHERWISE NOTED).
CONTRACTOR TO PROVIDE AND INSTALL NEW COVER PLATES WHERE MISSING OR DAMAGED TO
ACHIEVE A LIKE NEW APPEARANCE THROUGHOUT TENANT SPACE.
5.
6.
7.
8.
CONTRACTOR TO PROVIDE AND INSTALL NEW 24 HOUR SUPPLEMENTAL AIR UNIT THIS ROOM PER
TENANT'S REQUIREMENTS. REFER TO MEP DOCUMENTS FOR SPECIFICATIONS.
ALL NEW RECEPTACLES, COVERPLATES & DEVICES SHOWN ARE TO MATCH EXISTING.
WHEN WIRING IS COMPLETE, ALL AFFECTED PANELS ARE TO BE LABELED.
EXISTING RECEPTACLES ARE TO BE REUSED WHERE THEIR LOCATION COORDINATES WITH THE
LOCATION OF NEW RECEPTACLES. RETROFIT AS REQUIRED TO MATCH NEW RECEPTACLE TYPE AND
STYLE.
DEDICATED QUADRUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT 18" A.F.F. TO CENTER OF
RECEPTACLE (UNLESS OTHERWISE NOTED).
INSTALLATION OF WIRING, RACEWAYS, AND DEVICES FOR AUTOMATIC FIRE ALARM SYSTEM WILL BE
IN ACCORDANCE WITH ALL APPLICABLE CITY CODES, N.F.P.A. CODES AND UNIFORM RULE 4A-48,
RULES AND REGULATIONS OF THE STATE FIRE MARSHAL'S OFFICE, F.S.633.01 AND F.S. 633.701.
REFER TO M.E.P. DOCUMENTS FOR SPECIFICATIONS.
9.
ALL POWER AND COMMUNICATION WIRING, DEVICES AND INSTALLATION SHALL CONFORM WITH THE
CURRENT STANDARD EDITION OF N.F.P.A., NATIONAL ELECTRICAL CODE, I.E.E.E., N.E.M.A., U.L., AND
ANY AND ALL OTHER APPLICABLE REGULATIONS AND ORDINANCES HAVING JURISDICTION OVER THE
SCOPE OF WORK.
10. CONTRACTOR TO PATCH AND REPAIR ALL SURFACES AND OBJECTS AFFECTED BY THE DEMOLITION
AND ADDITION OF POWER AND COMMUNICATIONS RECEPTACLES WITH MATERIALS AND METHODS
TO MATCH EXISTING CONDITIONS AND TO PROVIDE A UNIFORM NEW CONDITION. PREPARE GYPSUM
BOARD WALLS (TO CEILING HEIGHT) AND ALL OTHER GYPSUM BOARD SURFACES THROUGHOUT TO
ACHIEVE A UNIFORM, SMOOTH SURFACE FOR THE RECEIPT OF NEW FINISHES.
PRIOR TO CORE DRILLING, CONTRACTOR TO COORDINATE WITH THE BUILDING MANAGEMENT FOR
PROPER PROCEDURES, BUILDING RULES AND REGULATIONS REGARDING DRILLING.
11.
MIC
REF
COPY
RECEPTACLE TO SERVICE POWER/ COMMUNICATIONS REQUIREMENTS FOR COPIER.
RECEPTACLE TO SERVICE POWER REQUIREMENTS FOR REFRIGERATOR.
RECEPTACLE TO SERVICE POWER REQUIREMENTS FOR MICROWAVE.
RECEPTACLE TO SERVICE POWER REQUIREMENTS FOR INSTANTANEOUS INLINE WATER HEATER.
44"
44" INDICATES NON-STANDARD MOUNTING HEIGHT A.F.F. TO CENTER OF RECEPTACLE.
GFCIRECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER
E DENOTES EXISTING RECEPTACLE OR CONDITION TO REMAIN INSTALLED AND OPERATIONAL.
NDENOTES NEW RECEPTACLE OR CONDITION TO BE SUPPLIED AND INSTALLED BY CONTRACTOR.
TV
RECEPTACLE TO SERVICE POWER/ COMMUNICATIONS REQUIREMENTS FOR TELEVISION.
IH
#WS
INDICATES NUMBER OF WORKSTATIONS BEING FED BY WHIP OR POWER POLE.
ELECTRICAL WHIP CONNECTION TO TENANT'S WORKSTATION FURNITURE WITH FACEPLATE, MOUNTED
AT 18" A.F.F. TO CENTER OF JUNCTION BOX (UNLESS OTHERWISE NOTED - CONFIRM WITH TENANT'S
FURNITURE VENDOR). EXACT LOCATION TO BE COORDINATED WITH TENANT'S FURNITURE VENDOR IN
FIELD. GENERAL CONTRACTOR TO PROVIDE AND INSTALL QUADRUPLEX JUNCTION BOX, CONDUIT FOR
POWER FEED AND FACEPLATE. TENANT'S FURNITURE VENDOR TO PROVIDE AND CONNECT EACH
ELECTRICAL WHIP TO SYSTEMS FURNITURE. ELECTRICIAN TO TRIM TO MINIMUM LENGTH REQUIRED
FROM SOURCE TO FURNITURE SYSTEM CONNECTION AT PANEL BASE (COORDINATE IN FIELD).
GENERAL CONTRACTOR'S ELECTRICIAN TO PROVIDE FINAL ELECTRICAL CONNECTION.
VOICE/ DATA COMMUNICATION WHIP CONNECTION TO TENANT'S WORKSTATION FURNITURE WITH
FACEPLATE, MOUNTED AT 18" A.F.F. TO CENTER OF JUNCTION BOX (UNLESS OTHERWISE NOTED -
CONFIRM WITH TENANT'S FURNITURE VENDOR). EXACT LOCATION TO BE COORDINATED WITH TENANT'S
FURNITURE VENDOR IN FIELD. GENERAL CONTRACTOR TO PROVIDE AND INSTALL QUADRUPLEX
JUNCTION BOX, CONDUIT FOR VOICE/ DATA CABLE AND FACEPLATE. TENANT'S CABLE CONSULTANT TO
PROVIDE AND INSTALL EACH VOICE/ DATA WHIP IN FLEX CONDUIT TO BE MINIMUM LENGTH REQUIRED
FROM SOURCE TO FURNITURE SYSTEM CONNECTION AT PANEL BASE (COORDINATE IN FIELD).
TENANT'S CABLE CONSULTANT TO PROVIDE FINAL VOICE/ DATA COMMUNICATION CONNECTION.
COORDINATE EXACT LOCATION OF TV AND TV POWER/COMMUNICATIONS RECEPTACLES WITH
TENANT AND EQUIPMENT SPECIFICATIONS. REFER TO M.E.P. DRAWINGS FOR FURTHER
INFORMATION.
FLUSH FLOOR MOUNTED DUAL POWER AND COMMUNICATIONS PLUG-IN RECEPTACLE. REFER TO M.E.P.
DOCUMENTS FOR EXACT SPECIFICATIONS.
FLOOR CORE TO PROVIDE CONDUIT TO ACCOMMODATE HDMI TO WALL MOUNTED TV.
COORDINATE EXACT LOCATION OF FLOOR CORE WITH TENANT IN FIELD PRIOR TO CORE
DRILLING. CONTRACTOR TO COORDINATE EXACT WIRING REQUIREMENTS WITH TENANT AND
TENANT'S FURNITURE VENDOR.
CLOCK TYPE BOX TO ACCOMMODATE DUPLEX POWER, HDMI AND COAX PLUG-IN CONNECTIONS,
MOUNTED AT HEIGHT INDICATED ON PLAN TO CENTER OF RECEPTACLE, LEGRAND, PASS & SEYMOUR
TV2MW OR EQUAL. CABLE CONNECTION BY TENANT'S CABLE VENDOR.
P2
P3
COORDINATE EXACT LOCATION OF FLOOR CORE WITH TENANT IN FIELD PRIOR TO CORE
DRILLING. CONTRACTOR TO COORDINATE EXACT WIRING REQUIREMENTS WITH TENANT AND
TENANT'S FURNITURE VENDOR.
P4
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
1735
07/21/17
CC/JL
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
IS
SU
ED
F
OR
P
ER
MIT
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
A1.4
POWER PLAN
ELEVATOR
LOBBY
MEN
WOMEN
STAIRS
NORTH
PUBLIC
CORRIDOR
SOUTH
PUBLIC
CORRIDOR
STAIRS
FREIGHT
ELEVATOR
ELEC.
FREIGHT
ELEVATOR
FE
LVT-1
VB-1
PT-1
PT
-2
PT-2
LVT-1
VB-1
PT-1
CPT-1
VB-1
PT-1
CPT-1
VB-1
PT-1
CPT-1
VB-1
PT-1
CPT-1
VB-1
PT-1
CPT-1
VB-1
PT-1
CPT-1
VB-1
PT-1
LVT-1
VB-1
PT-1
CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT ADJACENT SURFACES DURING
INSTALLATION AND TO PROTECT FINAL INSTALLED FINISH MATERIAL(S) FROM OTHER TRADES.
ALL FINISH DESIGNATIONS ARE SHOWN MONUMENTALLY UNLESS KEYED SPECIFICALLY ON PLAN.
ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAMEPROOF IN AN APPROVED MANNER.
ALL MATERIALS SHALL BE INSPECTED FOR FLAWS, DEFECTS OR DISCOLORATION PRIOR TO CUTTING
OR INSTALLATION.
ALL DRAPERY POCKETS, COLUMNS, FASCIAS, SOFFITS, DOOR/WINDOW TRANSOM CONDITIONS, AND
PARTIAL HEIGHT WALLS ARE TO RECEIVE WALL FINISHES AS INDICATED ON PLANS. CONTRACTOR
SHALL VERIFY LOCATION OF ABOVE AND SIMILAR ELEMENTS PRIOR TO DETERMINATION OF BID.
CONTRACTOR TO PROVIDE BUILDING MANAGEMENT AND TENANT WITH COPIES OF MANUFACTURER'S
WRITTEN WARRANTY AND APPROVED MAINTENANCE SPECIFICATIONS IMMEDIATELY UPON
COMPLETION OF WORK.
ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN
SPECIFICATIONS FOR THE PARTICULAR SURFACE. TWO (2) FINISH COATS MINIMUM APPLICATION
AFTER ONE PRIME COAT.
CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK'S COMPLIANCE WITH ALL APPLICABLE LOCAL
CODES, ORDINANCES, AND REGULATIONS AND WITH ALL ACCESSIBILITY REQUIREMENTS AS
OUTLINED IN CHAPTER 11 OF THE FLORIDA BUILDING CODE, AS WELL AS WITH ALL TRADE STANDARDS
OF PROFESSIONAL QUALITY WORKMANSHIP.
CONTRACTOR(S) SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB
SITE WHICH WILL IMPACT OR INTERFACE WITH HIS WORK AND BE RESPONSIBLE FOR SAME. ANY
DISCREPANCIES BETWEEN ACTUAL SITE CONDITIONS AND CONTRACT DOCUMENTS ARE TO BE
BROUGHT TO THE ATTENTION OF THE BUILDING MANAGEMENT AND DESIGNER PRIOR TO THE
COMMENCEMENT OF WORK.
CONTRACTOR(S) SHALL ADHERE TO ALL CURRENT MANUFACTURER WRITTEN SPECIFICATIONS FOR
APPROVED INSTALLATION METHODS (FOR EXAMPLE, BUT NOT LIMITED TO, ADHESIVE TYPES, CUTTING
METHODS, SEALERS AND PRIMERS) AND SHALL INFORM DESIGNER AND BUILDING MANAGEMENT
SHOULD MANUFACTURER NOT HAVE SUCH WRITTEN MATERIAL.
ALL FINISHES ARE TO BE PROVIDED AND INSTALLED BY PROFESSIONAL CONTRACTORS, QUALIFIED
TO INSTALL THE TYPE OF FINISH SPECIFIED.
17.
16.
15.
14.
13.
12.
10.
11.
9.
7.
6.
5.
F I N I S H P L A N - G E N E R A L N O T E S
4.
3.
2.
1.
ALL CHANGES IN FLOOR FINISH MATERIALS OCCURRING AT DOORWAYS SHALL BE AT THE CENTERLINE
OF THE DOOR OR DOORWAY UNLESS NOTED OTHERWISE. ALL OTHER FLOOR FINISH TRANSITIONS
SHALL BE ACCOMPLISHED SMOOTHLY TO THE SATISFACTION OF THE DESIGNER AND BUILDING
MANAGEMENT.
CONTRACTOR SHALL VERIFY LOCATIONS OF ALL CONSTRUCTION AND/ OR MILLWORK WHICH WILL
IMPACT HIS WORK PRIOR TO COMMENCEMENT OF WORK.
8.
ALL MISCELLANEOUS GRILLS, DIFFUSERS, AND FIRE EXTINGUISHER CABINETS OCCURRING ON
PARTITIONS OR CEILINGS ARE TO BE PAINTED TO MATCH THE SURFACE ON WHICH THEY OCCUR.
CONTRACTOR TO PREP ALL WALLS TO RECEIVE BASE AS SCHEDULED ON FINISH PLAN. CONTRACTOR
TO PATCH AND REPAIR WALLS AS REQUIRED TO ACHIEVE A UNIFORM, SMOOTH SURFACE FOR THE
RECEIPT OF NEW VINYL OR WOOD BASE. FLOORS AND WALLS MUST BE CLEAN AND FREE OF DUST,
DIRT, ALL PAINTS, WALL FINISH AND OTHER FOREIGN MATTER, WHICH MAY AFFECT ADHESIVE BONDING
OR MECHANICAL CONNECTION. FOLLOW MANUFACTURER'S WRITTEN SPECIFICATIONS FOR FURTHER
INSTALLATION INSTRUCTIONS.
CONTRACTOR TO PROVIDE ACTUAL SAMPLES OF ALL SPECIFIED FINISHES AND MATERIAL TO CMK
DESIGN STUDIO FOR APPROVAL PRIOR TO ORDERING. SAMPLES SHALL BE SUBMITTED IN A TIMELY
MANNER AS TO NOT IMPACT THE OVERALL PROJECT SCHEDULE.
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS WITH RESPECT TO NEW INSTALLATION,
PRIOR TO BID PROPOSAL COMPLETION.
DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.18.
COMMENTS
PT-1
GENERAL
PAINT
VB-1
VINYL
BASE
MANUF:
COLOR:
PROFILE:
HEIGHT:
F I N I S H S C H E D U L E
KEY
MANUF:
STYLE:
COLOR:
SIZE:
DESCRIPTION
LVT-1
LUXURY VINYL
TILE
MANUF:
STYLE:
COLOR:
SIZE:
PROVIDE SCHLUTER SCHIENE TRANSITION
AT ALL LVT TO CARPET FLOOR
TRANSITIONS, HEIGHT TO MATCH LVT.
MANUF:
COLOR:
FINISH:
PL-1
PLASTIC
LAMINATE
MANUF:
STYLE:
COLOR:
SS-1
SOLID
SURFACE
QUARTZ
FLOOR
BASE
WALL
PT-2
ACCENT
PAINT
JOHNSONITE
WHITE, 50
COVE
4"
SHAW LVT
GRAIN 0364V
ASHEN, 64155
7" X 48"
SHERWIN WILLIAMS
SKI SLOPE, SW 6518
EGGSHELL @ WALLS
FORMICA
464-G
GRAYSTONE, GLOSS FINISH
SHAW CONTRACT GROUP
NO RULES, SHAPE
GAZE
24" X 24"
CPT-1
CARPET TILE
F I N I S H S Y M B O L K E Y
IDENTIFIES FINISHES THAT
ARE USED MONOLITHICALLY
IN THE ROOM OR AREA
MANUF:
COLOR:
FINISH:
SHERWIN WILLIAMS
INDIGO, SW6531
EGGSHELL @ WALLS
MANUF:
STYLE:
COLOR:
WILSONART
Q1005
ARLINGTON
PROVIDE AT ALL CABINETS
PROVIDE AT ALL COUNTERTOPS AND
BACKSPLASHES
INSTALL LINEAR DIRECTION OF TILE TO
RUN NORTH/SOUTH AS INDICATED ON PLAN
INSTALLATION METHOD BY TENANT
IDENTIFIES LINEAR
DIRECTION OF FLOORING
MATERIAL
CLASS/
RATING
CLASS 1
CLASS 1
CLASS 1
CLASS A
CONFIRM DOOR FRAME PAINT COLOR WITH TENANT.19.
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
1735
07/21/17
CC/JL
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
IS
SU
ED
F
OR
P
ER
MIT
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
A1.5
FINISH PLAN
NON-RATED METAL STUD AND DRYWALL ASSEMBLY FROM
SLAB TO UNDERSIDE OF DECK ABOVE
BASE AS SCHEDULED
METAL STUD CHANNEL
(1) LAYER 5/8" GWB EACH
SIDE
METAL STUD CHANNEL
SLAB TO SLAB NON-RATED INSULATED PARTITION
3-5/8" 25 GA. METAL
STUDS @ 24" O.C.
ACOUSTICAL TILE
CEILING
UNDERSIDE OF DECK
ABOVE
BATT INSULATION,
FRICTION FIT INTO CAVITY
1. PARTITIONS SHALL BE SECURELY FASTENED AT TOP,
BOTTOM AND TERMINATIONS IN ACCORDANCE WITH
THE FLORIDA BUILDING CODE. THE FOLLOWING ARE
MINIMUM REQUIREMENTS - CONTRACTOR SHALL USE
ADDITIONAL FASTENERS AS REQUIRED BY
CONDITIONS ENCOUNTERED IN THE FIELD.
2. WHERE ATTACHING TO CONCRETE SLABS, USE TWO
(2) .145" DIAMETER POWDER-DRIVEN FASTENERS AT
24" O.C. MIN.
3. WHERE ATTACHING TO WOOD SHEATHING OR
BLOCKING, USE TWO (2) NO. 12-14 SCREWS AT 24" O.C.
PARTITION FASTENING NOTES
12
NON-RATED METAL STUD AND DRYWALL ASSEMBLY FROM
SLAB TO CEILING.
BASE AS SCHEDULED
METAL STUD CHANNEL
(1) LAYER 5/8" GWB EACH
SIDE
METAL TOP TRACK ATTACHED
TO CEILING GRID SYSTEM
WITH METAL FASTENERS
SLAB TO CEILING NON-RATED PARTITION
3-5/8" 25 GA. METAL
STUDS @ 24" O.C.
ACOUSTICAL TILE
CEILING
UNDERSIDE OF DECK ABOVE
BRACE PARTITION TO UNDERSIDE OF
DECK ABOVE AT LOCATIONS WHERE
UPPER MILLWORK OR EQUIPMENT IS
SCHEDULED TO BE INSTALLED ON
PARTITION.
NON-RATED METAL STUD AND DRYWALL ASSEMBLY SLAB
TO 4" ABOVE ACOUSTICAL CEILING SYSTEM.
BASE AS SCHEDULED
METAL STUD CHANNEL
(1) LAYER 5/8" GWB EACH
SIDE
METAL STUD CHANNEL
SLAB TO ABOVE CEILING, NON-RATED, INSULATED PARTITION
3-5/8" 25 GA. METAL
STUDS @ 24" O.C.
UNDERSIDE OF DECK ABOVE
MTL BRACING AS REQUIRED
CEILING AS SCHEDULED
BATT INSULATION,
FRICTION FIT INTO CAVITY
3
A
3'-0"
1/2" CLEAR TEMPERED
GLASS PANELS
1/A
2.1
2/A
2.1
8'-0" V
.I.F
.
1/2" CLEAR TEMPERED
GLASS DOOR
METAL PULLS, BOTH
SIDES, BRUSHED AL
FINISH
CONFIRM # OF GLASS PANELS AND SIZE WITH EXISTING
CONDITIONS IN FIELD. MAX GLASS WIDTH 4'-0".
GLASS PANEL SIZE VARIES. PANELS TO BE EQUAL WIDTHS
AT EACH CONDITION, VERIFY IN FIELD.
PROVIDE COPOLYMER STRIPS BY C.R. LAURENCE BETWEEN
GLASS PANELS.
PROVIDE SHOP DRAWINGS TO BUILDING MANAGEMENT FOR
REVIEW AND APPROVAL PRIOR TO ORDERING MATERIALS.
1.
NOTES:
2.
3.
9'-0"
4.
9'-0" A.F.F.
V.I.F.
EXISTING DECK
CONTINUOUS
CORNER BEAD TYP.
3/8" CLEAR TEMPERED
GLAZING IN RECESSED ALUM.
CHANNEL
WOOD BLOCKING
RECESSED ALUM.
CHANNEL
8'-0" A.F.F.
SCREW-ATTACH PARTITION
TO DECK ABOVE WITH (2)
POWDER-DRIVEN
FASTENERS AT 16" O.C.
3 5/8" 25 GA. MTL
STUDS @ 16" O.C.
MTL TRACK TO MATCH
STUD GAUGE AND WIDTH
PROVIDE 3 5/8" MTL STUD
DIAGONAL BRACING AT 16"
O.C.
(7) EQ. DOORS
A2.1
7
REFRIGERATOR
BY TENANT
ALIG
N
*2'-5"
PROVIDE CUT-OUT AT
BACK OF CABINET TO
WALL-MOUNTED
RECEPTACLE
*2'-11" ON
ANGLE-VIF
(3) EQ.
DOORS
*VERIFY APPLIANCE DIMENSIONS PRIOR TO FABRICATION
OF MILLWORK. ALLOW CLEARANCE FOR REFRIGERATOR
DOOR TO FULLY OPEN.
11'-8" ON ANGLE-VIF
FINISHED END
PANEL
FINISHED END
PANEL
A2.1
6
A2.1
5
2'-6"
(3) EQ.
DOORS
COUNTERTOP TO
EXTEND TO WALL
LINE OF WALL AT
CORNER
4" H. BACKSPLASH (SS-1)
1/4" MDF BACK PANEL WITH CUT OUT TO RIGHT
SIDE OF SHELF FOR ELECTRICAL RECEPTACLE
PLASTIC LAMINATE FINISH (PL-1)
3/4" MDF DOOR ON CONCEALED
EUROPEAN STYLE HINGES, PLASTIC
LAMINATE FINISH (PL-1)
ALL INTERIOR SURFACES TO BE MELAMINE,
TYP.
1 X 3 NAILERS, TYP.
2X FIRE RETARDANT TREATED
WOOD BLOCKING AS REQUIRED
FOR SUPPORT OF CABINETS, TYP.
PARTITION AS SCHEDULED
CEILING AS SCHEDULED
1'-8"
ALL INTERIOR SURFACES OF MICROWAVE
SHELF/OPENING TO BE PLASTIC LAMINATE
FINISH (PL-1)
2'-10"
2'-0"
SINK AND FAUCET - REFER TO M.E.P.
DRAWINGS FOR SPECIFICATIONS
3/4" MDF FIXED PANEL, PLASTIC
LAMINATE FINISH (PL-1)
3/4" MDF TOE KICK FACE, PLASTIC
LAMINATE FINISH (PL-1)
1/4" MDF BACK, MELAMINE FINISH
1/2" THICK COUNTERTOP (SS-1).
COORDINATE SUBSTRATE WITH
MILLWORK SUB-CONTRACTOR.
3/4" MDF DOOR ON CONCEALED EUROPEAN
STYLE HINGES, PLASTIC LAMINATE FINISH
(PL-1)
BRACING AND SUPPORT UNDER CABINET
BASE AND BEHIND TOE KICK FACE AS
REQUIRED
4" H. BACKSPLASH (SS-1)
3/4" MDF DOOR ON CONCEALED
EUROPEAN STYLE HINGES, PLASTIC
LAMINATE FINISH (PL-1)
1/4" MDF BACK, MELAMINE FINISH
ALL INTERIOR SURFACES TO BE MELAMINE,
TYP.
(1) ADJUSTABLE 3/4" MDF SHELF,
MELAMINE FINISH - LINE-BORE
ADJUSTMENT HOLES 1" O.C. AND PROVIDE
HEAVY DUTY SHELF CLIPS
1 X 3 NAILERS, TYP.
2X FIRE RETARDANT TREATED WOOD
BLOCKING AS REQUIRED FOR
SUPPORT OF CABINETS, TYP.
PARTITION AS SCHEDULED
CEILING AS SCHEDULED
2'-1"
2'-0"
3"
4"
1 1/2"
6"
MIN
.
1'-0"
CLEAR
2'-6"
10"
8 1/2"
4"
2'-10"
1/2" THICK COUNTERTOP (SS-1).
COORDINATE SUBSTRATE WITH
MILLWORK SUB-CONTRACTOR.
8 1/2"
2'-0"
4" H. BACKSPLASH (SS-1)
2'-1"
3/4" MDF DOOR ON CONCEALED
EUROPEAN STYLE HINGES, PLASTIC
LAMINATE FINISH (PL-1)
1/4" MDF BACK, MELAMINE FINISH
ALL INTERIOR SURFACES TO BE MELAMINE,
TYP.
(1) ADJUSTABLE 3/4" MDF SHELF,
MELAMINE FINISH - LINE-BORE
ADJUSTMENT HOLES 1" O.C. AND
PROVIDE HEAVY DUTY SHELF CLIPS
1 X 3 NAILERS, TYP.
2X FIRE RETARDANT TREATED
WOOD BLOCKING AS REQUIRED
FOR SUPPORT OF CABINETS, TYP.
10"
4"
6"
1'-0"
3/4" MDF TOE KICK FACE, PLASTIC
LAMINATE FINISH (PL-1)
1/4" MDF BACK, MELAMINE FINISH
3/4" MDF DOOR ON CONCEALED
EUROPEAN STYLE HINGES, PLASTIC
LAMINATE FINISH (PL-1)
BRACING AND SUPPORT UNDER
CABINET BASE AND BEHIND TOE KICK
FACE AS REQUIRED
3/4" MDF DRAWER WITH PLASTIC LAMINATE
EXTERIOR FINISH (PL-2) AND MELAMINE
INTERIOR FINISH, ON FULL EXTENSION
GLIDES, TYP.
(1) ADJUSTABLE 3/4" MDF SHELF, MELAMINE
FINISH - LINE-BORE ADJUSTMENT HOLES 1"
O.C. AND PROVIDE HEAVY DUTY SHELF
CLIPS
CABINET PULL, TYP.
PARTITION AS SCHEDULED
CEILING AS SCHEDULED
2'-0"
3"
1 1/2"
6"
MIN
.
1'-0"
CLEAR
2'-6"
4"
1'-2"
2'-10"
1/2" THICK COUNTERTOP (SS-1). COORDINATE
SUBSTRATE WITH MILLWORK
SUB-CONTRACTOR.
2'-1"
1'-8"
1'-8"
CABINET PULL, TYP.
CABINET PULL, TYP.
CABINET PULL, TYP.
CABINET PULL, TYP.
2'-0"
4"
6"
1'-0"
3/4" MDF TOE KICK FACE, PLASTIC
LAMINATE FINISH (PL-1)
1/4" MDF BACK, MELAMINE FINISH
3/4" MDF DOOR ON CONCEALED
EUROPEAN STYLE HINGES, PLASTIC
LAMINATE FINISH (PL-1)
BRACING AND SUPPORT UNDER
CABINET BASE AND BEHIND TOE KICK
FACE AS REQUIRED
3/4" MDF DRAWER WITH PLASTIC LAMINATE
EXTERIOR FINISH PL-2 AND MELAMINE
INTERIOR FINISH, ON FULL EXTENSION
GLIDES, TYP.
(1) ADJUSTABLE 3/4" MDF SHELF, MELAMINE
FINISH - LINE-BORE ADJUSTMENT HOLES 1"
O.C. AND PROVIDE HEAVY DUTY SHELF
CLIPS
CABINET PULL, TYP.
3"
1 1/2"
MIN
.
4"
1'-0"
CLEAR
PROVIDE 1" RADIUS EDGE AT FRONT CORNERS
OF PLASTIC LAMINATE SHELF, FINISH PL-1
LINE OF CABINET BEYOND
CONTRACTOR SHALL SUBMIT (2) SETS OF SHOP DRAWINGS
TO BUILDING MANAGEMENT FOR APPROVAL PRIOR TO
COMMENCEMENT OF WORK OR ORDERING OF ANY
MATERIALS.
MILLWORK GENERAL NOTES
ALL HINGES SHALL BE MIN. 110° CONCEALED EUROPEAN
STYLE. ALL DRAWER SLIDES SHALL BE FULL EXTENSION.
ALL HARDWARE SHALL BE PROVIDED AND INSTALLED BY
CONTRACTOR, UNLESS OTHERWISE NOTED.
ALL CABINETRY SHALL BE FLUSH OVERLAY STYLE.
ALL MILLWORK SHALL BE BUILT AND INSTALLED IN
ACCORDANCE WITH CUSTOM GRADE PER ARCHITECTURAL
WOODWORK INSTITUTE (AWI) QUALITY STANDARDS.
ALL INTERIOR SURFACES SHALL BE WHITE MELAMINE,
UNLESS OTHERWISE NOTED.
A.
B.
C.
D.
E.
F.
CONTRACTOR TO CONFIRM EXACT SPECIFICATION OF
CABINET PULL WITH BUILDING MANAGEMENT AND
TENANT.
G.
CONTINUOUS
CORNER BEAD TYP.
3/8" CLEAR TEMPERED
GLAZING IN RECESSED ALUM.
CHANNEL
WOOD BLOCKING
RECESSED ALUM.
CHANNEL
1"
GLAZING AS
SCHEDULED
1" ALUM. "C"
CHANNEL
**USE WHITE GASKET
@ ALL ALUM. GLASS
TRACKS**
B
2/A
2.1
SIM
.
3'-6"
3/A
2.1
8'-0" V
.I.F
.
3/8" CLEAR TEMPERED
GLASS PANELS WITH
CLEAR SILICONE
SEALANT
10"
DOOR AS
SCHEDULED
VARIES
V.I.F.
9'-0"
GLASS PANEL SIZE VARIES. CONFIRM WITH CONDITIONS IN
FIELD.
PROVIDE SHOP DRAWINGS TO BUILDING MANAGEMENT FOR
REVIEW AND APPROVAL PRIOR TO ORDERING MATERIALS.
1.
NOTES:
2.
ALIGN
IS
SU
ED
F
OR
P
ER
MIT
A2.1
PARTITION TYPES, ELEVATIONS &
DETAILS
PARTITION TYPES (1" = 1'-0")
GLAZING DETAIL - SILL
A2.1
2
3" = 1'-0"
GLAZING DETAILS
GLAZING DETAIL - HEAD
A2.1
3
3" = 1'-0"
GLAZING DETAIL - SILL
A2.1
1
3" = 1'-0"
ELEVATION - BREAK
A2.1
4
3/8" = 1'-0"
SECTION - SINK CABINET
A2.1
5
3/4" = 1'-0"
SECTION - DRAWER CABINET
A2.1
6
3/4" = 1'-0"
SECTION - MICROWAVE CABINET
A2.1
7
3/4" = 1'-0"
S H E E T N O.
S H E E T T I T L E
J O B N O.
I S S U E D A T E:
D R A W N B Y:
NO. REVISIONS DATE
Drawing Not Valid Unless Signed,
Sealed & Dated By Registered Professional
1735
07/21/17
CC
SCALE: 1/8" = 1'-0"
0 1' 5' 10'
6822 22nd Ave. N. #148St. Petersburg, Florida 33710
Ph: 727.515.8461
Planning & Design of the Built Environment
FL. LIC. NO.: AA26002603
CMK Design Studio, Inc.
IN
TE
RIO
R R
EN
OV
AT
IO
N
PH
OE
NIX
M
AR
KE
TIN
G IN
TE
RN
AT
IO
NA
L
TA
MP
A, F
LO
RID
A 3
36
02
40
0 N
A
SH
LE
Y D
RIV
E, S
UIT
E 1
97
5
WINDOW TYPES (3/8" = 1'-0")