The benefits of lighting controlsModern lighting controls deliver a range of benefits, most of whichcan be measured in real improvements to the profits of a business.From straightforward energy savings, through reduced maintenancecosts to potential increases in productivity, lighting controls haveclearly demonstrated their worth.Over the past 25 years Philips lighting controls have developed a fullrange of solutions designed to deliver these benefits.

Energy SavingNo business likes to be seen to be wasteful. Lighting controls ensurethat lighting is only provided when and where it is needed.Advancedsensors are used to integrate daylight and to detect occupancy.Thesesolutions have been shown to reduce lighting use by as much as 75%.Result-no obvious waste or compromise of comfort.

Installation Cost SavingOccupancy sensors and wireless infra-red controls avoid the use ofwired switches. Control products compatible with a ‘plug-in’approach to installation can save up to 70% of the ‘on-site’ labourtime.And these savings continue during the life of the buildingwhenever changes are needed.

ComfortIn business today the provision of a comfortable environment forpeople to learn, work, shop, eat, rest and play is vital for success.With Philips’ controls, the lighting can be set to suit the task, theexperience, individual preferences and tge required mood – and thenreadily change them as well.

SafetyThere is an increasing awareness of safety and well being, with agrowing emphasis on the importance of emergency lighting.

FlexibilityIt is said that the only certainty in life is that things will change.Anybuilding that cannot be readily adapted to changing business needsand use is not acceptable today. Philips lighting controls are designedto facilitate change-rapidly and effectively–whatever the application.

Meeting LegislationClimate change, as well as health and safety are provokinggovernments into making more and more regulations, standards andlegislation. Often lighting alone will not easily meet these demandswithout the addition of a control solution. In this field, Philps lightingcontrols has unrivalled knowledge and experience to share.

MaintenanceThe easier it is to maintain a lighting installation the lower the costof ownership.A Philips lighting management solution can extend lamplife, provide regular maintenance schedules and report on thecondition of emergency lights. Our lighting management solutionsensure that exit route lighting is maintained during periods ofoccupancy and emergency lighting is effectively tested andmonitored.

Health and well being – Total cost of ownership

L I G H T I N G C O N T R O L S 11.3

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.3

Page 4: PHL-H11_INT

Lighting controls – Key features

DMX

E

Lighting effects

11. Maintained illuminanceSet desired light levels and maintain them throughout the life of the

lamp to achieve significant cost savings.

12. Dimming controlAs more and more light sources can be economically dimmed, lighting

controls need to provide both switching and dimming capabilities.

13. Grouping of lighting circuitsManaging a comfortably lit interior often involves one group of lights

influencing the status of another circuit.

14. Corridor linkingHolding lights on in common circulation areas and corridors during all

occupied hours is an important contribution to comfort and safety.

15. Scene-settingTo meet the needs of different tasks, events or moods, a selection of

lighting scenes can be created, stored and recalled at the touch of a

button.

16. Control of any lighting typeAs lighting designs often require multiple types of lamps, Lighting

Controls provide the freedom to choose any suitable lamps.

17. Colour changingThe ability to change the colour temperature of a lighting installation

makes it possible to eather create a more comfortable working

environment or introduce dynamic lighting effects in architecture.

System connectivity

18. Link to other building controlsThe Lighting Controls product range includes numerous possibilities for

different building control and management systems to share information

and functions.

19. Full LonWorks® InteroperabilityAchieve seamless integration into building-wide control systems by

using a standard network protocol.

20. Digital Adressable Lighting InterfaceThe Digital Addressable Lighting Interface is the latest standard control

interface for high-frequency electronic ballasts. With this new

technology, control circuits are completely independent of supply

wiring.

21. DMX interfaceThe standard protocol for the audio/visual and theatre industry. This

interface links complex lighting scenes to presentations and displays.

Automatic control

1. Movement detectionTo control lighting within a specific area, sensing of occupancy by

movement detection ensures that lights are activated only when

needed.

2. Daylight linkingNatural light is energy-saving and beneficial to individual users. Light

output can respond to daylight conditions, maintaining a constant level

of indoor lighting and ensuring comfort at all times.

3.Time scheduleDaily programming of the management of lighting installations enables

the correct lighting levels to be achieved at all times, by changing

lighting levels, by switching lights on and off or by adjusting the way

control systems respond to other devices.

Manual control

4. Pushbuttons/wall switchesLighting Control systems can also be operated manually by connecting

conventional wall switches or pushbuttons to inputs in the lighting

control module.

5. Infrared remote controlIn offices and meeting rooms where the lighting requirements change

frequently, wireless infrared control offers the flexibility to set the

lighting, and change it at any time.

6. PC control via IT network (TCP/IP)For high-level lighting management, the control system can be linked to

a LAN. This option gives individual users’ control over their local

working environment.

7.Telephone handset control (via PABX)To enhance individual comfort, telephones can be connected to a

lighting management system for a cost-effective way of letting users

control their local lighting.

Monitoring

8. Hours run loggingKeep track of lamp hours and produce precisely targeted relamping

schedules and detailed departmental cost allocations.

9. Emergency lighting test and monitorLighting management systems offer a reliable way to carry out statutory

testing of emergency and exit lighting, without interfering with the

normal operation of standard luminaires.

10. Current lighting statusThe ability to get a real-time view of the status of all the lights in a

building on a floor-by-floor basis enhances effective facility management.

11.4 L I G H T I N G C O N T R O L S

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.4

Page 5: PHL-H11_INT

Lighting controls – System selection matrix

DMX

E

Systems Stand alone Luminaire based

Helio Lightmaster Scenio 100 Scenio Trios Occuswitch Intelligent LinesenseMultiDim luminaires

Automatic control page 11.15 page 11.16 page 11.27 page 11.31 page 11.10 page 11.6 page 11.28

Movement detection • • • • • • • •Daylight linking • • • • •Time schedule • • •Manual control

Push buttons/switches • • • • • •Infrared remote control • • • • • • •PC control • • o

Telephone control via PABX o

Monitoring

Hours run logging o •Emergency testing and logging o •Lighting effects

Maintained illuminance • • • • •Switching and dimming • • • • • • •Grouping functionality • • • •Corridor linking • •Scene setting • • • • • •Control of any lighting type • • • • • •Colour changing o o • •System Connectivity

Link to other building mgt. syst. • • •Full LonWorks® interoperability •Digital Adressable Lighting Interface • • o • • •DMX interface •

• standard option o project special

Philips offers a range of innovative lighting control products thatmeet the demands of many sizes and types of application.Whetherthe project is a large HQ office building, requiring a full lightingmanagement system, or a small refurbishment job involving a coupleof rooms, there is a Philips lighting control to suit the application.When matching your project to our lighting control products usethe following criteria as your initial guide to product selection:

• The functionality required – dimming, flexibility ….• The scale of the project (and hence its budget…)• The application – office, hotel, shop, industry, etc.

Other factors to bear in mind include the choice of lighting design aswell as any requirement for local user controls and/or occupancyresponse.

L I G H T I N G C O N T R O L S 11.5

page11.30/11.26

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.5

Page 6: PHL-H11_INT

Luminaire based and basic solutions

Occulux – Movement-dependent daylight regulationAs a combination of a state-of-the-art light sensor and a miniaturemovement detector, Occulux regulates lighting levels depending onthe amount of daylight entering a room and on occupation.Theincreasing need for flexibility means that lights often remain onunnecessarily. On the other hand, turning lights off in certain areas ofan open plan office can create an unpleasant visual impression.Occulux therefore dims light down to a minimum lighting level whenan area is unoccupied.The result is a constant, pleasant lighting levelfor office workers with a maintained adjustable minimum, enablingowners to benefit from considerable savings on energy costs of upto 50%.

Luxsense – Daylight-dependent regulation optionLuminaires with this option contain a unobtrusive light sensor,regulating light to the required level depending on the amount ofdaylight. Energy saving results from both the use of daylight and thecompensation of the over-design effect (maintained illuminance).With today’s efficient lamps and optics, the compensation of theover-design is very effective, particularly in retrofit projects.Averageenergy savings can reach up to 35%. Luxsense is also available as aseparate product for both TL5 and TL-D luminaires.

Philips intelligent luminaires – The simplest way to lighting controlTo increase comfort, energy saving and flexibility in offices, Philips hasincorporated miniature lighting controls within the luminaires.Philips Lighting offers a choice of intelligent luminaire solutions thatprovide a wide range of functions such as daylight linking, movementdetection, remote control and scene setting with energy savings ofup to 70%. Intelligent luminaires enable lighting control to be appliedin a building at any stage of a project.The sensor-controllercombination within the luminaire has little impact, or none at all, onthe electrical installation.

Omnisense – All intelligence in onePrimarily designed for cellular and smaller open plan offices,Omnisense can also be applied in other areas such as meetingrooms, toilets and storage rooms. By using the benefits of digitaltechnology, Omnisense provides 10 pre-programmed modes tomatch a variety of applications quickly and easily. Each mode includesa varies parameters such as delay times and switching behaviour. Inaddition to daylight regulation and movement detection, infraredremote control enables users to interact with their environment:switch, dim or select preset lighting levels or scenes. Omnisensefunctionality can be changed easily so that its behaviour can beadapted to new situations.

11.6 L I G H T I N G C O N T R O L S

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.6

Page 7: PHL-H11_INT

Occuswitch – Lighting control the easy wayThe Occuswitch is a very simple occupancy type controller thatprovides automatic switching of lighting loads of up to 10A.A built-inadjustable time delay allows the lights to remain on after occupancyfor a selected period of time.An optional light sensor is also built-inso that if the natural daylight conditions are sufficient the lights willnot switch on thus saving more energy.

The Occuswitch distinguishes itself in design, quality and ease ofinstallation; it is simply positioned in the middle of the room or area,the mains power supply wired directly to it and the luminaire circuitwired from it. Simplicity at its best! Occuswitch is ideally suited forthose areas that are infrequently occupied and where dimming is notrequired - such as washrooms, stores, lobbies, corridors, cellularoffices and meeting rooms.A version with manual IR remoteoverride control is also available.

L I G H T I N G C O N T R O L S 11.7

Occuswitch

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.7

Page 8: PHL-H11_INT

11.8 L I G H T I N G C O N T R O L S

Lighting controls Omnisense, Occulux, Luxsense

~LIGHTM~Lightmaster

LRI1661 Omnisense- Easy selection of 10 building application modes

with commissioning tool IRT8099- Mounting height: approx. 3 m- Default setting light level: 500 - 600 lux- Easy adjustment of required light level with

commissioning tool- Movement detection area 20 m2

- Master-slave installation: up to 7 DALI luminairescan be slaved to 1 luminaire equipped withOmnisense provided they all remain in themovement detection area

- Reliable Philips RC5 infrared protocol- Can be used with or without bracket, depending

on luminaire type- Available as option for many luminaires

LRI1340 Occulux- Mounting height: approx. 3 m- Default setting light level: 500 - 600 lux- Easy manual adjustment of minimum light level

during absence- Movement detection area 20 m2

- Master-slave installation: up to 7 HFR luminairescan be slaved to 1 luminaire equipped withOcculux provided they all remain in the movementdetection area

- Can be used with or without bracket, dependingon luminaire type

- Available as option for many luminaires

LRL1220 Luxsense- Mounting height: 2-4 m- Default setting light level: 500 - 600 lux- Easy manual adjustment of required light level

IRT8099 Commissioning tool for Omnisense luminaires.Easy to use and inexpensive tool to adjust lightlevels and to switch between functionality modes.Batteries are included.

Product ID European Order

Code (EOC)

IRT8099/00 51889300

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.8

Page 9: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.9

Lighting controls

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.9

Page 10: PHL-H11_INT

11.10 L I G H T I N G C O N T R O L S

Lighting controls Occuswitch

LRM1050/00Movement detector with built-in lighting switch.Theunit is designed for the automatic switching oflighting in indoor applications. Connection: Screwterminals. Switch-off delay time from 1 to 35 min.(selectable).The pattern of sensitivity is nearlycircular ; covering an area with a diameter of about7 m. Mounting height 2.5 to 3 m. Daylight-override10 to 1000 lux (selectable), factory set at 750 lux.Max. switching current 10 A rms (any load).

LRM1051/00Movement detector with built-in lighting switch.Theunit is designed for the automatic switching oflighting in indoor applications. Connection:Wielandconnectors GST 18-3 male/female. Switch-off delaytime from 1 to 35 min. (selectable).The pattern ofsensitivity is nearly circular ; covering an area with adiameter of about 7 m. Mounting height 2.5 to 3 m.Daylight-override 10 to 1000 lux (selectable), factoryset at 750 lux. Max. switching current 10 A rms (anyload).

LRM1060/00Movement detector with built-in lighting switch and aninfrared receiver, enabling manual control(OVERRIDE).The unit is designed for the automaticswitching of lighting in indoor applications. Connection:Screw terminals. Switch-off delay time from 1 to35 min. (selectable).The pattern of sensitivity is nearlycircular; covering an area with a diameter of about7 m. Mounting height 2.5 to 3 m. Daylight-override 10 to 1000 lux (selectable), factory set at 750 lux.Max. switching current 10 A rms (any load).

~HELIO~Helio lighting management system

LRM1061/00Movement detector with built-in lighting switch andan infrared receiver, enabling manual control(OVERRIDE).The unit is designed for the automaticswitching of lighting in indoor applications.Connection:Wieland connectors GST 18-3male/female. Switch-off delay time from 1 to 35 min.(selectable).The pattern of sensitivity is nearlycircular ; covering an area with a diameter of about7 m. Mounting height 2.5 to 3 m. Daylight-override10 to 1000 lux (selectable), factory set at 750 lux.Max. switching current 10 A rms (any load).

Product ID Weight

(kg)

European Order

Code (EOC)

LRM1050/00 SENSR MOV DET ST 0.26 51725400

LRM1051/00 SENSR MOV DET PLUG 0.34 51732200

LRM1060/00 SENSR MOV DET ST IR 0.26 51734600

LRM1061/00 SENSR MOV DET PLUG IR 0.34 51736000

Dimensions in mm

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.10

Page 11: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.11

Lighting controls Occuswitch

Product ID Weight

(kg)

European Order

Code (EOC)

LRM1064/00 SENSR ABS DET ST IR 0.26 51755100

LRM1065/00 SENSR ABS DET PLUG IR 0.34 51757500

IRT8010/00 TRANSM IR POINT 0.06 51749000

IRT8050/00 TRANSM IR 2KEY WALL 0.12 51707000

LRM1064/00Movement detector with built-in lighting switch andan infrared receiver, enabling manual control(MANUAL SWITCH ON).The unit is designed forthe automatic switching of lighting in indoorapplications. Connection: Screw terminals. Switch-offdelay time from 1 to 35 min. (selectable).Thepattern of sensitivity is nearly circular ; covering anarea with a diameter of about 7 m. Mounting height2.5 to 3 m. Daylight-override 10 to 1000 lux(selectable), factory set at 750 lux. Max. switchingcurrent 10 A rms (any load).

LRM1065/00Movement detector with built-in lighting switch andan infrared receiver, enabling manual control(MANUAL SWITCH ON).The unit is designed forthe automatic switching of lighting in indoorapplications. Connection:Wieland connectors GST 18-3 male/female. Switch-off delay time from1 to 35 min. (selectable).The pattern of sensitivity isnearly circular ; covering an area with a diameter ofabout 7 m. Mounting height 2.5 to 3 m. Daylight-override 10 to 1000 lux (selectable), factory set at750 lux. Max. switching current 10 A rms (any load).

Dimensions in mm

IRT8010/00 IRT8050/00LRH8010/00

ASSOCIATED PRODUCTS

LRH8010/00 MOUNT IR POINT 0.03 51797100

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.11

Page 12: PHL-H11_INT

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.12

Page 13: PHL-H11_INT

The working environment

People think and work better in a comfortable environment, which

leads to better productivity.Today's office buildings need to be

adaptable to the needs of both individual users and the companies

they work for.A networked lighting management system is an

essential part of a modern lighting installation.

Flexibility

Change - in a modern building this can happen every day. Philips'

lighting management systems have been developed with change in

mind. From the easily installed hardware to the user-friendly local

override facilities these solutions make change much easier to deal

with, while still delivering the individual lighting levels chosen by the

staff.

Lighting management

L I G H T I N G C O N T R O L S 11.13

PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.13

Page 14: PHL-H11_INT

LightMaster – Networked lighting managementLightMaster is a family of networked lighting controls, which are veryattractive to budget-conscious users, designers and installers.LightMaster components are built into a simple, yet highly flexiblenetworked lighting control and monitoring system, that also offerssimple and effective integration possibilities.

With building use changing regularly, often within months, theexpense of reconfiguration is now an important factor for everybuilding operator.This system is specifically designed to facilitate anyrequired changes in the lighting installation through the powerful yeteasy-to-use LightManager software suite. Monitoring facilities rangefrom simple status indication to sophisticated event and run-timelogging.

LightMaster

9-output LCM, switching and dimming

Luminaire

Multi-sensor

Wall switch

2. Changed configuration (lay-out)Caption1. Intial configuration

User-friendly graphicsLightManager is both the configuration tool and the user interfacefor LightMaster.The package is specifically designed to run underMicrosoft Windows, ensuring that it has a familiar ‘look and feel’ towelcome the user. Building plans and lighting layouts are importedfrom AutoCAD or other industry-standard design packages.Thesefiles then become the foundation of the lighting control system’ssupervisory software. Easily understood icons that give absoluteclarity to the facilities management team illustrate all the lightingsystem components.

11.14 L I G H T I N G C O N T R O L S

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.14

Page 15: PHL-H11_INT

2-output LCM

8-output LCM, either switchingonly or switching and dimming

Luminaire

LON multi-sensor or conventional (multi-) sensor

InfraRed receiver

Heating & ventilation controller

Sunblind controller

Helio - Innovation by integrationHelio is a lighting control system for building-wide control, which canbecome an integral part of the building management concept usingone network. Its open system architecture, open communicationsprotocol and standardised technology allow Helio to be easilyintegrated with systems supplied by different vendors such asheating, ventilation, window blinds, building access and more.

Integration on all levelsHelio is based on Echelon’s LonWorks® technology, the de factostandard for leading suppliers of building services controls. Plug-insfor other tools, such as LonMaker for Windows®, are also provided.

As a result Helio offers numerous solutions for lighting andintegration, driven by users’ demands for investment benefits,functionality and upgradeability.Three levels of lighting solutions giveyou virtually unlimited possibilities.These range from abasic solution for centralised lighting control, through a system with more advanced control functions usingsensors, transmitters and pushbuttons, to a fullyintegrated approach to building controls.

Helio

1. Get ready for integration2. Take control with sensors,

transmitters and pushbuttons3. Complete integration

with HVAC systems and sunblinds

L I G H T I N G C O N T R O L S 11.15

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.15

Page 16: PHL-H11_INT

11.16 L I G H T I N G C O N T R O L S

Lighting controls Lightmaster

~LIGHTM~Lightmaster

LBC5000/00Central Supervisor. IBM compatible PC withsoftware and interface card, user interface to theLM100 system. A Central Supervisor can control upto 60 Area Controllers.Also available:LBC5001/02 Interface Card and LightManagerSoftware to be used with a PC provided by theclient.

LFC5255/00Area Controller. A building controlled by a LM100system is split into a number of areas. Each area issupervised with an Area Controller.The AreaController manages network traffic, schedules timecommands and implements re-configurationcommands from the Central Supervisor.

LLC5319Pluggable Lighting Control Module with 4 inputs and9 outputs (Wieland GST). Each output can beconfigured to control any light or combination oflights anywhere on the system. Each individualoutput is allowed to switch up to 4 A, with amaximum for all outputs up to 10 A divided overthe two sides, each 5 A. Requires the LRH5300/50base to be mounted on.Versions available:LLC5319/50 Pluggable LCM (1-10V).LLC5319/70 Pluggable LCM for use with DALIballasts (no feedback).LLC5319/71 Pluggable LCM for use with DALIballasts (limited feedback).LLC5359/50 Pluggable LCM (1-10V) for use withRC5 IR remote control.

LRH5300/50Base to be used with LLC5319 Lighting ControlModules.

Product ID Weight

(kg)

European Order

Code (EOC)

LBC5000/00 SOFTW A62PC+SOFTW 4.00 53552400

LBC5001/02 SOFTW CARD+SOFTW 0.15 53734400

LFC5255/00 NETWK AREA CONTR 2.44 53932400

LLC5319/50 CONTR 9X4 PLUG SW&RE 1.71 53460200

LLC5319/70 CONTR 9X4 PLUG SW&RE D-NO 1.00 53710800

LLC5319/71 CONTR 9X4 PLUG SW&RE D-LIM 1.80 53762700

LLC5359/50 CONTR 9X4 PLUG SW&RE RC5 1.71 53930000

LRH5300/50 CONTR BASE ASSY PLUG 1.26 53422000

Dimensions in mm

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.16

Page 17: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.17

Lighting controls Lightmaster

LLC5314/50Lighting Control Module with screw terminals for4 inputs and 4 outputs (1-10 V).This unit is used tocontrol circuits of lights. Each input can beconfigured to control any light or combination oflights anywhere on the system. Requires theLRH5304/50 Base to be mounted on. Dimensiondrawing includes the base (LRH5304/50).

LRH5304/50Base to be used with LLC5314/50 Lighting ControlModule. Dimension drawing includes the lightingcontrol module (LCC5314/50).

LLC5702Gear Tray Lighting Control Module with terminalsfor 2 outputs and 2 inputs in metal enclosure. Eachinput can be configured to control any light orcombination of lights anywhere on the system.Versions available:LLC5702/41 1 Gear Tray Lighting Control Module inmetal enclosure.LLC5702/42 2 Gear Tray Lighting Control Modulesin 1 metal enclosure.LLC5702/73 1 Gear Tray Lighting Control Module inmetal enclosure with one DALI output, 16 addressesand feedback, 2 inputs.

LLC5702/50Separate Gear Tray Lighting Control Module. Can bemounted inside a luminaire or switch cabinet.1-10V analogue dimming.LLC5702/72 Gear Tray Lighting Control Module,with single DALI output, 16 addresses and feedback,2 inputs.

Product ID Weight

(kg)

European Order

Code (EOC)

LLC5314/50 CONTR 4X4 ST SW&RE 0.89 53572200

LRH5304/50 CONTR BASE ASSY ST 2.14 53590600

LLC5702/41 CONTR 2X2 GT SW&RE TIN 1.37 53412100

LLC5702/42 CONTR 2X2 GT SW&RE 2TIN 1.72 53413800

LLC5702/50 CONTR 2X2 GT SW&RE 0.36 53574600

LLC5702/72 CONTR 16X2 GT SW&RE D 0.40 53756600

Dimensions in mm

LLC5702/73 CONTR 16X2 GT SW&RE IN 1.37 53758000

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.17

Page 18: PHL-H11_INT

11.18 L I G H T I N G C O N T R O L S

Lighting controls Lightmaster

LLC5714/00Input Module for DIN Rail mounting.

LLC5714/41Input Module with 4 inputs in metal enclosure.Allows the connection of 4 sensors or switches.Each sensor or switch can be configured to controlany light or combination of lights anywhere on thesystem.

LLC5724/41Output Module with 4 outputs in metal enclosure.It has screw terminals for 4 light circuits. Each of theoutputs can be addressed individually.

LLC5724/50Output Module for DIN Rail mounting.

Dimensions in mm

Product ID Weight

(kg)

European Order

Code (EOC)

LLC5714/00 CONTR 0X4 DIN 0.28 53414500

LLC5714/41 CONTR 0X4 DIN TIN 1.70 53416900

LLC5724/41 CONTR 4X0 DIN SW&RE TIN 1.84 53417600

LLC5724/50 CONTR 4X0 DIN SW&RE 0.47 53578400

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.18

Page 19: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.19

Lighting controls Helio lighting management system

~HELIO~Helio lighting management system

LRC5040/10Helio light controller with single channel forswitching and regulating lighting loads up to 5 A, andproviding a sensor interface for standard IRreceivers, pushbutton interface units, movementdetectors, and light sensors.

LRC5042/00Helio light controller with two separately controlledoutputs and one interface for standard movement,light and infrared sensors.The outputs are able toswitch and regulate lighting loads up to 5 A.Theoutputs and LON bus have screw connections, thesensor interface is connected via RJ12 plug.

LRC5043/00Helio light controller identical to the LRC5042 butwith two sensor interfaces for standard movementdetectors, lights sensor and IR receiver and twoinputs for standard wall switches.The outputs have a6-pole screw conector that provides Live, Neutral,Protective Earth, Maintained live for power supply tobatteries in emergency luminaires and a + and - for 1 - 10 V dimming.

LRC5038/10Helio light controller with eight switchable outputs,two pairs of sensor interfaces for standardmovement detectors, light sensors, IR receivers andtwo inputs for standard wall switches.The outputsare able to switch lighting loads up to 4 A.The unithas a maximum total rating of 10 A divided over thetwo sides, each 5 A. Each output has a 3-poleWieland socket (GST) that provides Live, Neutraland Protective Earth.

Product ID Weight

(kg)

European Order

Code (EOC)

LRC5040/10 CONTR 1x1 ST SW&RE 0.47 51625700

LRC5042/00 CONTR 2x1 ST SW&RE 1.10 51727800

LRC5043/00 CONTR 2x2 ST SW&RE 1.20 53708500

LRC5038/10 CONTR 8x4 PLUG S 1.48 53740500

Dimensions in mm

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.19

Page 20: PHL-H11_INT

11.20 L I G H T I N G C O N T R O L S

Lighting controls Helio lighting management system

LRC5048/00Helio light controller with eight separately controlledoutputs and two interfaces for standard movementdetectors, light sensors and pushbutton switches.Theoutputs are able to switch and regulate lighting loadsup to 5 A.The unit has a maximum total rating of16 A. Each output has a 6-pole Wieland socket(GST) that includes a maintained live for powersupply to batteries in emergency luminaires. Batteryperformance can then be tested by interrupting themaintained power supply at prescribed intervals.

LRI5133/10Helio multi-sensor with movement detector, lightsensor, and infrared receiver used for remote andautomatic control of lighting, HVAC and sun blindfunctions in integrated room control applications.TheIR receiver can be combined with hand-held and walltransmitters for remote control operations and withwall transmitters with built-in temperature sensors forautomatic temperature control. Units are connecteddirectly to LonWorks® bus cable for networkcommunication and power supply.Their functionalbehaviour can adapted by downloading projectspecific software over the bus.

Mounting plate for surface mounting of LRI5133.This plate is packed together with the sensor itself.

Mounting ring for recessed mounting of LRI5133.This ring is packed together with the sensor itself.

Product ID Weight

(kg)

European Order

Code (EOC)

LRC5048/00 CONTR 8x4 PLUG SW&RE 3.00 51688200

LRI5133/10 SENSR LON MULTISENSOR 0.30 51684400

Dimensions in mm

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.20

Page 21: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.21

Lighting controls Helio lighting management system

LCU5305/00Helio digital I/O module providing a simple drycontact interface to and from various systems.The unit has 2 inputs and 2 outputs.

LCU5315/20Helio system clock providing a real time clock andprogrammable switching schedule.

LCN5225/00Helio bus power supply unit providing a voltage of42 V DC and a current of 1.4 A to the linkpowerbus.The bus voltage and current is used by devicesusing LPT transceivers like Helio sensors, systemclocks and digital I/Os.

LCN5235/00Helio bus power supply/repeater regenerating buscommunication and providing power to the bus.

Product ID Weight

(kg)

European Order

Code (EOC)

LCU5305/00 NETWK 2x2 DIG I/O 0.20 51614100

LCU5315/20 NETWK CLOCK 0.20 51615800

LCN5225/00 NETWK POWER 0.60 51611000

LCN5235/00 NETWK REPEATER 0.60 51612700

Dimensions in mm

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.21

Page 22: PHL-H11_INT

11.22 L I G H T I N G C O N T R O L S

Lighting controls Helio lighting management system

LCN5245/00Helio bus power supply/router repeaterregenerating and managing bus communication andproviding power to the bus.

Unilon software.Unilon is a general configuration tool forLonWorks® based systems. It offers a fully graphicaluser interface and many other features forcommissioning of LonWorks® systems. Each actualinstallation of one node in a network requires alicense, so-called credit key. Unilon is now available inclient and server version. Credits can be separatelyordered in variable amounts.The server packageincludes documentation files about Helio andUnilon.

Helio LNS™ Plug-ins.Plug-ins for other configuration tools likeLonMaker™ for Windows™ are also available. Formore information please contact your local PhilipsLighting Controls representative.

Product ID Weight

(kg)

European Order

Code (EOC)

LCN5245/00 NETWK ROUTER 0.60 51613400

LCC5301/00 CABLE BUS 100M 0.01 51714800

LCS5425/00 SOFTW UNILON CLIENT 0.10 51758200

LCS5430/00 SOFTW UNILON SERVER 0.60 51756800

LCS5435/00 SOFTW UNILON TRAIN 0.60 51849700

LCS5495/00 SOFTW UNILON CREDIT - 51759900

Dimensions in mm

LCC5301/00Lighting control busline, used to interconnect allsystem components of the Helio lightingmanagement system.The busline carries all data exchange between thevarious "modules" of Helio.The LCC5301 is a cable of 100 m withoutconnectors.

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.22

Page 23: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.23

Lighting controls

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.23

Page 24: PHL-H11_INT

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.24

Page 25: PHL-H11_INT

Caption

Colours set the mood and add emotion

Architecture and shops

Versatile control rangeScenio100 / MultiDim is a scene setting lighting control range thatcover a wide range of applications. It provides from simple tocomprehensive control facilities at the touch of a button.With aneasy-to-use remote control different preset scenes can beprogrammed and selected, changing the mood of the room inseconds.

Creative lighting designWith its capacity to control a large number of channels of lighting,the Scenio100 / MultiDim range is ideally suited for applications usingmany different types of luminaries for incandescent, halogen andfluorescent lamps. In addition Scenio100 / MultiDim can also be usedto switch on projectors, lower projection screens or close windowblinds at just the touch of a button.

Scene setting for all occasionsThe Scenio100 / MultiDim product range can be applied in situationssuch as conference halls, boardrooms, lecture theatres, hotelfunctions rooms, museums, showrooms, cafes, restaurants and shops.

Shoebaloo, Amsterdam

L I G H T I N G C O N T R O L S 11.25

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.25

Page 26: PHL-H11_INT

MultiDim

Freedom in lighting designMultiDim offers unbeatable freedom and ease of lighting systemdesign.The MultiDim controllers can be used in combination withDALI-compatible fluorescent lamp ballasts and lamp interface units(both high voltage incandescent lamps and low voltage halogenlamps).Where necessary control functions can be provided by addingthe required MultiDim units such as dimmers, control panels, IRremote control units and multi sensors for light levels and roomoccupancy.

Maximising flexibility with DALI Thanks to the systems digital addressable control andcommunication concept, each unit in the DALI network has its ownunique address that allows it to be switched and controlledindependently.The systems single control line can be used to controldifferent groups of lamps, and up to 63 devices connected to thesame physical control wire can be addressed and controlledindependently.

Digital control solutionPhilips DALI MultiDim offers today’s most versatile and easy-to-install solution that brings the benefits of digital lighting control tomany different application areas.Whether in shops, offices,conference rooms, hotels, restaurants or other applications.

Quick and economic installationMultiDim consists of an integrated range of DALI-compatible devicesthat can be combined flexibly to create exactly the desired controlfunctions.The systems addressable digital architecture means thatonly a single two-core cable is needed to interconnect all units.Thepossibility to eliminate conventional vertical wall wiring both reducesinstallation time and cost, and greatly increases the ease with whichlater changes can be implemented.

MultiDim product range

11.26 L I G H T I N G C O N T R O L S

PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.26

Page 27: PHL-H11_INT

Control Interfaces Scenes can be controlled by LCD touch screen, infrared remotecontrol and manual button control plate. Control plates with a satinanodised aluminium finish are standard available, with otherdecorative finishes optional available. Partition switches join andseparate the control of rooms with demountable partitions.

Powerful control solutionScenio100 enables the lighting designer to achieve the correctambience for all occasions. Either simple or advanced effects may beset at the touch of a button, including dynamic lighting and colourchange as well as daylight linking and time control options. Scenesare created via software run on a PC, LCD touch screen or byinfrared hand held transmitter.

Flexibility in applicationsIn retail areas time sequenced scene and colour changing is used tostimulate sales by highlighting products and creating an excitingenvironment. In restaurants Scenio100 provides the right atmospherefor a light breakfast, a working lunch or an intimate dinner.Other indoor applications include: museums, exhibition andconference centres, lecture theatres, leisure centres, stadiums, hotels,public buildings and prestige homes. Scenio100 is also highly effectivein outdoor applications, particularly floodlighting.

Choice of Dimming RacksTungsten, low voltage, LED, cold cathode, fluorescent and all otherdimmable light sources may be controlled using phase cutting, digitalor DC voltage techniques. Dimming modules are built into compact,standard or custom-built racks, which are connected by a serial databus to create a multi-channel control solution. Racks feature a mainsinput isolator and circuit breakers for individual output protection, aswell as inputs for serial and DMX control, and voltage free contactsproviding an interface to other building management systems.

Scenio100

For further information about the versatileScenio 100 system, please contact your localPhilips Lighting representative.

L I G H T I N G C O N T R O L S 11.27

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.27

Page 28: PHL-H11_INT

Easy to installThe Linesense range comprises a supplementary 300 mm trunkingelement, containing the controller, for addition to the TTX400 lightline.This extra unit is easily installed between the light line and theelectrical connection unit – the “6th click” in the TTX400 system.High bay movement detectors and, optionally, a light sensor aresimply connected through RJ-12 modular cables to the dedicatedbrackets. Once installed, the system works automatically and requiresno extra maintenance.

Energy savingLinesense, in combination with the highly efficient TTX400luminaires, decreases energy costs substantially by using presencedetection, daylight linking and manual control.Examples show that energy savings up to 75% can be achieved.WithLinesense energy savings are realised from day one, with noadditional costs in the long run.

Industry lighting systems - Linesense

Lighting controls in industry

Industrial buildings today are

models of efficiency in meeting

their specific purpose – be it a

logistics’ warehouse or a major

manufacturing complex. Lighting in

these environments plays the

same important role as it does in

any other work place.

Philips industrial lighting control

solutions are specifically intended

to meet the exacting demands of

these buildings to be both cost

effective and well lit facilities.

Linesense extention with movement detector

Lighting controls for TTX400 light-linesToday’s warehouses and distribution centres can be characterised bytheir large size and the few people employed. Light is switched on allday although the employees need it only for a limited time. For thoseapplications Philips Lighting offers a stand-alone control solution,Linesense, to be used in combination with TTX400 light-lines.Linesense dims or even switches off the lights when nobody ispresent in a particular zone.

11.28 L I G H T I N G C O N T R O L S

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.28

Page 29: PHL-H11_INT

Caption

Digital intelligence for Light-linesThe LON-DALI control system provides optimal lighting where it’sneeded and when it’s needed. Promoting maximum productivity,comfort and safety.A system, moreover, that’s simple to operate andto adapt to changing industrial requirements. Providing a uniquesolution that truly reflects the needs of modern industry – today andinto the future.

Adaptive to needs and activitiesThe LON-DALI system allows creating lighting zones within andacross light-lines (TTX400 and Maxos). It offers total flexibility tocontrol the lighting behaviour of each zone and even to reprogramthe zones into a new lighting arrangement to accommodate changesin floor layout or production activity. New arrangements can besoftware configured with no need for rewiring.

Optimal lighting The system, moreover, accommodates time control, manual control,movement detection and daylight regulation – resulting in optimalillumination of all tasks on the factory floor and increasing operatorproductivity, efficiency, comfort and safety.

Taking control The LON-DALI controller allows for status monitoring includingindividual lamp and ballast status, burning hours and energyconsumption in each light zone. Ensuring that the light lineinstallation always functions at optimum efficiency, and allowing foraccurate cost allocation to individual departments using theinstallation.The controller provides the means to have thisinformation to be integrated into a modern Building ManagementSystem.

LON-DALI

LRC5140/41- LON-DALI light controller for industryLON-DALI system solution

L I G H T I N G C O N T R O L S 11.29

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.29

Page 30: PHL-H11_INT

11.30 L I G H T I N G C O N T R O L S

Lighting controls Trios system

Product ID Weight

(kg)

European Order

Code (EOC)

LRC1010/10 CONTR 1x1 ST S 0.46 51643100

LRC1020/10 CONTR 1x1 ST SW&RE 0.46 51645500

LRC1030/00 CONTR 1x1 PROG ST SW&RE 0.46 51583000

LRC1015/10 CONTR 1x1 DIN S 0.33 51644800

LRC1025/10 CONTR 1x1 DIN SW&RE 0.33 51646200

LRC1035/00 CONTR 1x1 PROG DIN SW&RE 0.33 51586100

LRC1010/10LRC1020/10LRC1030/00Trios multifunctional and addressable light controllersin a housing for distributed installation in threeversions.The switching (LRC1010) and theswitching/regulating (LRC1020) versions have pre-defined functionalities that depend on theconnection of movement detector, infrared receiverand/or light sensor.They are specifically designed forenergy saving solutions with dimmable and non-dimmable luminaires.The functionality of theswitching and regulating LRC1030 can be adaptedby PC programming software (available separately)for special lighting control applications. A highlyinformative Trios Manual is available to assistdesigners and installers in selecting the correctproducts for their applications.

LRC1015/10LRC1025/10LRC1035/00Trios multifunctional and addressable light controllersin a DIN-rail housing for centralised installation inthree versions.The switching (LRC1015) and theswitching/regulating (LRC1025) versions have pre-defined functionalities that depend on theconnection of a movement detector, infraredreceiver and/or light sensor.They are specificallydesigned for energy saving solutions with dimmableand non-dimmable luminaires.The functionality ofthe switching and regulating LRC1035 can beadapted by PC programming software (availableseparately) for special lighting control applications.A highly informative Trios Manual is available to assistdesigners and installers in selecting the correctproducts for their applications.

LCS1030/00Trios SoftwareSoftware for use on a PC to alter the parameters ofthe LRC1030/1035 controllers.Trios HandbookTrios Handbook, intended to assist consultants,engineers, installers and other professionals involvedin project management and design, and in specifyingand procuring lighting control systems. Its purpose isto aid the reader in selecting the most effectivelighting solution for a particular applicationrequirement. It describes the fundamentaltechnicalities of the Trios system and its associatedcomponents, and gives detailed information oninstallation, test and commissioning.More information: www.controls4lighting.com

~HELIO~Helio lighting management system

Dimensions in mm

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.30

Page 31: PHL-H11_INT

Lighting controls Scenio system

Product ID Weight

(kg)

European Order

Code (EOC)

IRT8020/00 TRANSM IR SCENIO 0.22 51761200

LRC1505/00 CONTR 1X0 EXTENSION 0.35 51651600

LRC1555/00 CONTR 1X1 0.35 51653000

IRT8020/00Eight-preset hand-held transmitter, suitable forinfrared control of Scenio applications. It has 4 keysfor presets and one key for “all off ”. Keys forindividual control and preset programming arelocated under a hinged cover at the bottom of thetransmitter. In “teach mode” the transmitter can beused as a commissioning tool for Scenio.The groupaddress selector switch is contained in the batterycompartment.The unit is supplied complete withwall holder and batteries.

LRC1505/00Scenio extension module to be linked to the lightcontroller LRC1555 via a communication bus line. Ithas two modular sockets, both intended for busloop-through connections. Sensors (IR receivers,movement detectors) cannot be connected to thisunit.The unit has one output channel suitable toswitch a maximum load of 1150 VA, and a 1-10 VDC regulating output. A 20 cm buslineinterconnection cable is supplied with the unit.

LRC1555/00Scenio light controller with two modular sockets:one dedicated for sensors (IR receivers and/ormovement detectors) and the other for bus-interconnection to the extension modules LRC1505.Up to three IR receivers and three movementdetectors can be connected to the sensor input.The unit has one output channel suitable to switch amaximum load of 1150 VA, and a 1-10 V DCregulation output.

Dimensions in mm

~TRIOS~Trios system

L I G H T I N G C O N T R O L S 11.31

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.31

Page 32: PHL-H11_INT

11.32 L I G H T I N G C O N T R O L S

Lighting controls General purpose components

~GENERAL~General purpose components

IRT8010/00Hand-held two-key transmitter, for infrared control ofvarious lighting control systems.This transmitter wasdeveloped for the Occuswitch “presence” and“absence”, but it can also be used with Trios andother systems.The Occuswitch-IR is only able toswitch, but when the transmitter is used with thenamed systems it can also dim the lights (by pressinga button >0.5 sec).The group address selector switchis contained in the battery compartment.The unit issupplied with batteries. A wall holder is available.

IRT8030/00Four-preset hand-held transmitter, suitable forinfrared control of Trios applications. It has 4 keys forpresets and one key for “all off ”. Keys for individualcontrol and preset programming are located under ahinged cover at the bottom of the transmitter. In“teach mode” the transmitter can be used ascommissioning tool for Trios.The group addressselector switch is contained in the batterycompartment.The unit is supplied complete withwall holder and batteries.

IRT8050/00Two-key infrared remote control transmitter for wallmounting and table-top use.The unit can be used inTrios applications.The actual function of the twolarge keys can be selected with a dip switch in thebattery compartment. A dip switch is also used toselect the group address.

Dimensions in mm

Product ID Weight

(kg)

European Order

Code (EOC)

IRT8010/00 TRANSM IR POINT 0.06 51749000

IRT8030/00 TRANSM IR TRIOS 0.22 51763600

IRT8050/00 TRANSM IR 2KEY WALL 0.12 51707000

LRH8010/00Wall holder for the IRT8010 hand-held two-keytransmitter.

LRH8010/00 MOUNT IR POINT 0.03 51797100

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.32

Page 33: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.33

IRT8040/00Hand-held transmitter, suitable for infrared control ofHelio applications combined with HVAC andSunblind systems. It has keys for two lighting groups,blinds control and temperature control and a key for“all off/absence”. Keys for lighting presets and presetprogramming are located under a hinged cover atthe bottom of the transmitter.The group addressselector switch is contained in the batterycompartment.The unit is supplied complete withwall holder and batteries.

Lighting controls General purpose components

IRT8055/00Multi-purpose infrared remote control transmitterfor wall mounting, suitable for the transmission ofmeasured temperature values.The unit can be usedin integrated control systems with Heating,Ventilation and Airconditioning (HVAC) incombination with Helio applications.The actualfunction of the two large keys can be selected witha switch in the battery compartment.The sameswitch is used to select the group address. Onlyavailable as project special.

IRT8080/00Hand-held transmitter, suitable for infrared control ofvarious lighting control systems, other buildingsystems (sunblind, HVAC).The transmitter can easilybe adapted to project specifications by selecting oneof its 15 settings.This can be achieved without anytools, and even after installation.The group addressselector switch is contained in the batterycompartment.The unit is supplied complete withtext plates for the various settings, wall holder andbatteries.

Product ID Weight

(kg)

European Order

Code (EOC)

IRT8055/00 TRANSM IR 2KEY WALL TEMP 0.12 51843500

IRT8080/00 TRANSM IR MULTI-FUNC 0.22 51767400

Dimensions in mm

IRT8040/00 TRANSM IR SYS 0.22 51765000

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.33

Page 34: PHL-H11_INT

11.34 L I G H T I N G C O N T R O L S

Lighting controls General purpose components

Dimensions in mmLRM8114/00Compact advanced movement detector thatfeatures variable delay-to-off via DIP switch and canbe part shaded to limit coverage.The sensor ispowered via the additional modular plug-in (RJ12)connector cable that attaches it to a lightingcontroller.The sensor is suitable for both recessedand surface mounting. Mounting height is between2.5 m and 3.5 m.

LRI8134/00Compact multi-sensor combining advanced internallight sensor, movement detector and infra-redreceiver.The unit features individual elementselection, variable delay-to-off via DIP switch andauto-calibrating light sensor. Movement detector canbe part shaded to limit coverage.The sensor ispowered via the additional modular plug-in (RJ12)connector cable that attaches it to a lightingcontroller.The sensor is suitable for both recessedand surface mounting. Mounting height is between2.5 m and 3.5 m.

LRM8115/00Wall-mounted passive infrared movement detectorfor energy saving solutions in indoor lightingapplications (automatic light switching based onoccupancy). It detects the slightest movement withina range 25 m long. Equipped with adjustableswitchoff delay times up to 35 minutes. Electricalconnections via an additional sensor cable with amodular socket (“snap-in”).The daylight overridefunction prevents the lights being witched on, ifenough daylight is available.

LRM8116/00Wall-mounted passive infrared movement detectorfor energy saving solutions in indoor lightingapplications (automatic light switching based onoccupancy). It detects the slightest movement withinan angle of 90º (maximum range 15 m by 15 m at amounting height of 2.1 m). Equipped with adjustableswitchoff delay times up to 35 minutes. Electricalconnections via an additional sensor cable with amodular socket (“snap-in”).The daylight overridefunction prevents the lights being switched on, ifenough daylight is available.

Product ID Weight

(kg)

European Order

Code (EOC)

LRM8115/00 SENSR MOV DET LONG 0.07 51722300

LRM8116/00 SENSR MOV DET WIDE 0.07 51841100

LRM8114/00 SENSOR MOV DET 0.07 51906700

LRI8134/00 SENSOR MULTISENSOR 0.07 51904300

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.34

Page 35: PHL-H11_INT

L I G H T I N G C O N T R O L S 11.35

IRR8125/00Infrared receiver for remote control of lightingsystems and other building-related functions.The unitis especially intended for “invisible” mounting behinda false ceiling. Only a thin plastic optic protrudesfrom the ceiling. More infrared receivers can beconnected in parallel to cover large or odd-shapedrooms. It is powered from the correspondingcontroller, not requiring an external power supplyunit. Electrical connections with a fixed cable (1 m.)with modular plug. Mounting height 2.5 to 3 m.

Lighting controls General purpose components

Dimensions in mm

LCU8020/00Push-button interface. RC5 code generator withdigital inputs for the connection of push-buttons.Intended for manual control of light controllers andfor coupling to other systems such a buildingmanagement systems.The unit is connected to theinfrared remote control input of the controller.Combination with an IR receiver is possible. Codesgenerated, depend on the input terminals used,20 combinations are possible. Different sets ofcodes, for Helio/Trios and Scenio can be selectedwith a rotary switch.The unit is powered from thecorresponding controller.

LRD8000/00Light regulator for incandescent lamps, high-voltagehalogen lamps and low-voltage halogen lamps withconventional transformers.The minimum light outputlevel can be adjusted between 1% and 10% ofmaximum light output level. A green “power on”LED indicates the power status of the unit. Max. loadis 1000 VA.

LRD8010/10Light regulator for incandescent lamps, high-voltagehalogen lamps and low-voltage halogen lamps withelectronic transformers.The minimum light outputlevel can be selected between 1% and 10% ofmaximum light output level. A green “power on”LED indicates the power status of the unit. Max. loadis 1000 VA.

Weight

(kg)

European Order

Code (EOC)

LCU8020/00 INTERF PUSHBUTTON 0.10 51656100

LRD8000/00 DIMMER 1KVA MAGNETIC TX 0.40 51571700

LRD8010/10 DIMMER 1KVA ELECTRONIC TX 0.53 51573100

Product ID

IRR8125/00 SENSR IR NV 0.03 51716200

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.35

Page 36: PHL-H11_INT

11.36 L I G H T I N G C O N T R O L S

Lighting controls General purpose components

Dimensions in mmLPS100/00Manual rotary potentiometer with microswitch forrecessed mounting. In combination with one ormore electronic HF lightregulating ballasts, electroniclight regulators or Trios controllers, it serves tocontrol the light level of fluorescent lamps, halogenlamps or incandescent lamps.

LPS100/01Manual rotary potentiometer with microswitch forsurface mounting. In combination with one or moreelectronic HF light-regulating ballasts, electronic lightregulators or Trios controllers, it serves to controlthe light level of fluorescent lamps, halogen lamps orincandescent lamps.

Product ID European Order

Code (EOC)

LPS100/00 POTSW 1-10V DIM 0.14 55803900

LPS100/01 POTSW 1-10V DIM 0.14 55806000

Weight

(kg)

LCC8024/00Branching connector with three modular socketsand one modular plug for use when more sensorsare to be connected to the same controller inputsocket. (Or extension cable socket).

LCC8024/00 CONN BLOCK RJ12 1M-3F 0.01 51599100

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.36

Page 37: PHL-H11_INT

Lighting controls General purpose components

Dimensions in mm

LCC8011/00Interlink cable of 1 m length with modular plugs atboth ends for interconnection of multifunctional lightcontrollers so that the connected sensors can beshared by more controllers.

LCC8012/00/LCC8013/00Extension cables of 5 m length (LCC8012) and20 m length (LCC8013) with modular plugs andsockets to increase the distance between sensors(infrared receivers, light sensors and movementdetectors) and the corresponding controllers.

Product ID A

LCC8012/00 5000

LCC8013/00 20000

LCC8014/00Cable of 5 m length with modular plugs at bothends for the connection of sensors to the varioustypes of light controllers.

LCC8015/00Interlink cable of 5 m length with modular plugs onboth ends for interconnection of Trios lightcontrollers.The cable is intended to distribute (only)the RC5 signal from a push-button interface overthe connected controllers, especially in centrallycontrolled Trios applications.

Product ID Weight

(kg)

European Order

Code (EOC)

LCC8011/00 CABLE INTER RJ12M-RJ12M 1M 0.03 51593900

LCC8012/00 CABLE EXT RJ12M-RJ12F 5M 0.13 51595300

LCC8013/00 CABLE EXT RJ12M-RJ12F 20M 0.50 51597700

LCC8014/00 CABLE SENSR RJ12M-RJ12M 5M 0.12 51637000

LCC8015/00 CABLE IR RJ12M-RJ12M 5M 0.12 51711700

LCC8016/00 CABLE RJ12-END 3M 0.06 53920100

LCC8016/10 CABLE RJ12-BL4 3M 0.06 53922500

LCC8016/00LCC8016/10Sensor link cable of 3 m length with RJ12 connectoron one end. Intended to connect general purposesensors (excl. IRR8125) to LightMaster systems.The /00 is free end and /10 has a BL4 connector.

L I G H T I N G C O N T R O L S 11.37

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.37

Page 38: PHL-H11_INT

Lighting controls

11.38 L I G H T I N G C O N T R O L S

PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.38