STANDBY 800 ekW 1000 kVA50 Hz 1500 rpm 400 Volts
FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT
System Standard OptionalAir Inlet Single element canister type air cleaner (with
pre-cleaners)
Service indicator
Dual element & heavy duty air cleaners
Air inlet adapters & shutoff
Cooling Radiator with guard (43C)
Low Profile (frontal area)
Low Airflow
Coolant drain line with valve
Fan and belt guards
Caterpillar Extended Life Coolant*
Coolant level sensors*
Radiator duct flange
*Not included with packages without radiators
Radiator with 27C and 50C ambient capability
Radiant option for 57C ambient with treated water
Radiator removal
Heavy duty, harsh environment radiator at 43C and
50C
Heat exchanger and expansion tank
Coolant level switch gauge
Jacket water heater
Exhaust Dry exhaust manifold
Flanged faced outlets
Mufflers & Silencers
Stainless steel exhaust flex fittings
Elbows, flanges, expanders & Y adapters
Fuel Secondary fuel filters
Fuel priming pump
Flexible fuel lines
Fuel cooler**Not included on packages without radiators
Water separator
Duplex fuel filter
Generator Permanent magnet excited
Class H insulation
Class F temperature (105C prime/130C standby)
Reactive droop
Digital Voltage Regulator, 3-phase sensing
Bus bar connections
Winding temperature detectors
Anti-condensation space heaters
Digital Voltage Regulator with KVAR/PF control
Bearing temperature detectors
Oversize, premium & self-excited generators
Cable access box
European bus bars
Circuit breakers, UL listed, 3 pole with shunt trip (low
& medium voltage only)
Circuit breakers, IEC compliant, 3 pole with shunt trip
(low & medium voltage only)
Space heater relay
Power Termination Bus bar (NEMA and IEC mechanical lug holes)
-right side standard
Top and bottom cable entry
Circuit breakers, UL listed, 3 pole with shunt trip, 80%
or 100% rated, choice of trip units, manual or
electrically operated (low voltage only)
Circuit breakers, IEC compliant, 3 or 4 pole with shunttrip (low voltage only), choice of trip units, manual or
electrically operted
Shroud cover for bottom cable entry
Power terminations can be located on the left and/or
rear as an option. Also, multiple circuit breakers can
be ordered. (up to 3)
Governor Woodward 2301A isochronous Electronic load sharing
Control Panels User Interface panel (UIP) - rear mount
EMCP 3.1 Genset Controller
Speed adjust
AC&DC customer wiring area (right side)
CAT digital voltage regulator (CDVR) with KVAR/PF
control,3-phase sensing
Reactive droop Emergency Stop Pushbutton
EMCP3.3
Option for right or left mount UIP
Option for rear or left mount Customer wiring area
Voltage Adjust
Local and remote annunciator modules
Load share module
Discrete I/O module Generator temperature monitoring & protection
Lube Lubricating oil and filter
Oil drain line with valves
Fumes disposal
Gear type lube oil pump
Deep sump oil pan
Electric & air prelube pumps
Manual prelube with sump pump
Duplex oil filter
Oil level regulator
Mounting Structual Steel Tube
Anti-vibration mounts (shipped loose)
Isolator removal
Spring-tuype, zone 4
Starting/Charging 24 volt starting motor(s)
Batteries with rack and cables
Battery disconnect switch
Battery chargers (10&20 amp)
Oversize batteries
Ether starting aids
Heavy duty starting motors
Barring device (manual)
Air starting motor with control & silencer
General Crankcase explosion relief valves Automatic transfer switches (ATS)
EU Certificate of Conformance6 September 2006 1:58 A2
8/10/2019 PGS1000 kVA
3/6
STANDBY 800 ekW 1000 kVA50 Hz 1500 rpm 400 Volts
SPECIFICATIONS
CAT GENERATOR
SR4B GeneratorFrame size......................................................................... 692
Excitation................................................Permanent Magnet
Pitch.............................................................................. 0.7143
Number of poles...................................................................4
Number of bearings......................................................... 002
Insulation....................... UL 1446 Recognized Class H with
tropicalization and antiabrasionIP rating..........................................................Drip Proof IP22
Alignment.....................................................Closed Coupled
Overspeed capability - % of rated...................................180
Wave form....................................................................003.00
Voltage regulation............Less than +/- 1/2% (steady state)Less than +/- 1% (no load to full load)Paralleling kit/Droop transformer.......................... Standard
Voltage regulator.3 Phase sensing with selectible volts/Hz
Telephone Influence Factor.............................. Less than 50
Harmonic distortion......................................... Less than 5%
CAT DIESEL ENGINE
3508 TA, 4-stroke-cycle watercooled diesel
Bore - mm.............................................. 170.00 mm (6.69 in)
Stroke - mm........................................... 190.00 mm (7.48 in)
Displacement - L................................... 34.53 L (2107.15 in3
)Compression ratio........................................................ 13.5:1
Aspiration........................................................................... TA
Fuel system............................................Direct unit injection
Governor type...................................................... Woodward
CAT EMCP3 CONTROLS
EMCP3.1 (standard)
Integral to generator terminal box
Single location for customer connections
IP 23 enclosure
24 Volt DC control
UL/CSA/CE
Electrically dead front
Lockable hinged door
Run/Auto/Stop control
True RMS metering, 3-phase
Speed Adjust (Optional 3.1)
Digital indications for:
- RPM
- Operating hours
- Oil pressure
Coolant Temperature
- System DC volts
L-L volts, L-N volts, phase amps, Hz
- ekW, kVA, kVAR, kW-hr, %kW, PF
Shutdowns with indicating lights for:
- Low oil pressure
- Overspeed
- Emergency stop
Under and over frequency
- Reverse powerOvercurrent
MODBUS isolated data link (RS-485 half-duplex) supports
seriall communication at data rate up to 115.2 kbaud (*)
6 September 2006 1:59 A3
8/10/2019 PGS1000 kVA
4/6
8/10/2019 PGS1000 kVA
5/6
STANDBY 800 ekW 1000 kVA50 Hz 1500 rpm 400 Volts
RATING DEFINITIONS AND CONDITIONS
Meets or Exceeds International Specifications:AS1359,
AS2789, CSA, EGSA101P,IEC60034, ISO3046,
ISO8528,NEMA MG 1-32, UL508, 72/23/EEC, 89/336/EEC,
98/37/EEC.
Standby-Output available with varying load for the
duration of the interruption of the normal source power.
Standby power in accordance with ISO8528. Fuel stop
power in accordance with ISO3046, AS2789, and BS5514.
Standby ambient temperatures shown indicate a coolant
top tank temperature just below shutdown at 100 percent
load.
Ratingsare based on SAE J1995 standard conditions.
These ratings also apply at ISO3046 standard conditions.
Fuel Ratesare based on fuel oil of 35 API [16 C (60 F)]
gravity having an LHV of 42 780 kJ/kg (18,390 Btu/lb)
when used at 29 C (85 F) and weighing 838.9 g/liter
(7.001 lbs/U.S. gal.). Additional ratings may be available
for specific customer requirements. Consult your
Caterpillar representative for details.
6 September 2006 1:59 A5
8/10/2019 PGS1000 kVA
6/6
STANDBY 800 ekW 1000 kVA50 Hz 1500 rpm 400 Volts
DIMENSIONS
Package DimensionsLength 5256.2 mm 206.94 in
Width 1844.0 mm 72.6 in
Height 2128.2 mm 83.79 in
Weight 10 478 kg 23,100 lb
Note: Do not use for installation design.See general dimension drawings fordetail (Drawing #1532779).
www.CAT-ElectricPower.co
2006 CaterpillAll rights reserve
Materials and specifications are subject to change without noticThe International System of Units (SI) is used in this publication
CAT, CATERPILLAR, their respective logos and "Caterpillar Yellow," awell as corporate and product identity used herein, are trademarks o
Caterpillar and may not be used without permissio
7878757
Performance No.: TM4514
Feature Code:: 508DE47
Source:: European Sourced
6 September 2006
6