Z1.10.105ZM3045
0518Supersedes
New
R
Certified to CSAStandard C22.2 No.108.
**
© Copyright 2018 Zoeller® Co. All rights reserved.
ELECTRICAL DATA
PUMP NET WEIGHT: lbs (kg) 37 lbs (16.8 kg) MOTOR TYPE: SUBMERSIBLE
SERVICE FACTOR: 1.15 POWER CORD LENGTH: ft (m) 230V= SOOW 115V= SJOOW 20' (6.1m) _____'
MOTOR DESIGN LETTER: NEMA B MOTOR SHAFT: AISI 1215 STEEL
IMPELLER TYPE: PLASTIC STATOR INSULATION: CLASS B
SQUARE RING AND COVER GASKET: VITON LEAD WIRES INSULATION: CLASS B
RPM: 3450MAXIMUM STATOR
TEMPERATURE:266 °F (130 °C)
SHAFT SEAL CONSTRUCTION: STANDARD SILICON CARBIDE/ CARBON
MOTOR THERMAL SHUTOFF: STANDARD THERMAL OVERLOAD SWITCH WITH AUTOMATIC RESET
MAXIMUM WATER TEMPERATURE: 130 °F (54 °C)
MODEL NUMBER: 6155
PUMP NAME PLATE HORSEPOWER: 1/2 HP
SOLID SIZE: in (mm) 3/4" (19mm)
MINIMUM HEAD: ft. (m) 5.0' (1.5m)
MAXIMUM HEAD: ft. (m) 44' (13.4m)
MAX.FLOW GPM (L/min) @ MIN. HEAD ft. (m)
77 GPM @ 5' (291 L/min @ 1.5m)
DISCHARGE SIZE: VERTICAL FEMALE 1-1/2 NPT
MODEL HP 115 V / 1 Ph 230 V / 1 Ph
FLA LRA FLA LRA
6155 1/2 10.5 17.1 5.3 8.6
FLORIDA HYDRONICS 813-918-5433
PERFORMANCE DATA COMMERCIAL EFFLUENT PUMPS
MODEL 6155
GENERAL DATA
visit our web site: CarlosRivera.org
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
Carlos RiveraHighlight
Carlos RiveraHighlight
Carlos RiveraHighlight
SELECTION GUIDE
1. Single or Double piggyback variable level float switch pumpcontrol using the 15 amp plug and receptacle. Refer to ZM1536.
2. Single piggyback variable level float switch, hard wiring thepump lead wires to the float switch leads.
3. Refer to ZM1342 and select the correct simplex control panellisted for the pump. Refer to ZM1536 and select the desiredvariable level control switch, 3 required.
4. Refer to ZM1342 and select the correct duplex control panel listedfor the pump. Refer to ZM1536 and select the desired variablelevel control switch, 3 or 4 required.
FEATURES
• Motor - 1/2 HP, 60 Hz, 3450 RPM, 1 PH, oil filled, hermetically sealed,automatic reset, thermal overload protected (1 PH)
• Lower ball bearing• Motor shaft - AISI 1215 STEEL• Mechanical shaft seal silicon carbide/carbon• Viton O-ring seal and cover gasket• Impeller - engineered thermoplastic• 20' foot neoprene cord with plug• No screens to clog• Stainless steel screws, bolts and handle• 1-1/2" NPT discharge• Corrosion resistant powder coated epoxy finish• 100% computerized tested
CAUTIONAll installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).
For additional information on Zoeller products refer to catalog for; Rail Systems, ZM1347; Float Switch Brackets, ZM1328; Check Valves, ZM1348; Single Phase Controls, ZM1377; Three phase controls, ZM1342 and ZM1343; High Water Alarm Panels and Float Switches, ZM1536; Control Panels, ZM1342.
* Molded Plug ** Pumps are available with optional moisture sensors. Seal Fail indicator light available
in NEMA 4X control panels.
1-1/2" NPT
3-7/8" (98 mm)
3-7/8" (98 mm)
4-5/8"
6-7/32"
3-7/8" (98 mm)
5-3/8" (137 mm)
12-1/8" (308 mm)
(158 mm)
(117 mm)
SK2064
014500
© Copyright 2018 Zoeller® Co. All rights reserved.
MODELFeet
Shut-off Head:
6155Meters Gal. Liters
291771.551015
3.04.6
7061
265231
2025
6.17.6
5242
197159
3035
9.110.7
3322
12583
40 12.2 11 4244 ft.(13.4m)
TOTAL DYNAMIC HEAD/FLOWPER MINUTE
EFFLUENT AND DEWATERING
Models
Control Selection (See Selection Guide)
Listings
Volts Ph AmpsSim-plex
Du-plex
UL CSA
*N6155 115 1 10.5 1,2 or 3 4 no yes*E6155 230 1 5.3 1,2 or 3 4 no yes
014500
PUMPPERFORMANCE
CURVEMODEL 6155
0
104
20
830
12 40
50
0
20
80 160
40 60
240
80
LITERS
GALLONS
FLOW PER MINUTE
TOTA
L DY
NA
MIC
HEA
D
MET
ERS
FEET
Carlos RiveraHighlight
OIL SMART® PLUG AND PLAY SYSTEM
Printed in U.S.A. C281-REV-0116
The Oil Smart® OSS-100 System, when combined with a manual sump pump, will automatically pump water without the risk of pumping oil into the environment. The system will alert in the event of a high oil or high water condition. Installation of the OSS-100 allows you to comply with Elevator Code ASME A17.1 and State/Federal regulations while reducing the risk of adverse publicity, fines and expensive cleanup costs.
• Plug & play for easy installation• 120VAC, single phase, 60 hz.• Includes Oil Smart® pump control (OSS20PBPR6)
with 20′ cord and piggyback plug• Includes Oil Smart® alarm (OSA-05) with 10′ power
cord and Liquid Smart® sensor with 20′ cord• Pump control and alarm components differentiate
between oil and water• Alarm visible indicators: red beacon alarm light,
yellow light for oil, white light for water, alarm testand silence buttons
• Alarm horn sounds at 85 decibels at 10 feet• Remote monitoring dry contacts: oil, water and high
liquid• Panel and controls: UL listed for the United States
and Canada
Overview:
Features:
Applications:
• Elevator sumps• Electric utilities (substations, power plants,
underground vaults, and transformer barriers)• Manufacturing facilities• Any application where there is a need to remove
water while containing oil
SEEWATER, Inc.
OIL WATER
Oil Smart® High Liquid Alarm System
Patent No. 7,492,272, 7,830,268SILENCE TEST
PUMP STOP
PUMP START
HIGH LIQUID ALARM
Oil Smart® Pump Switch
Oil Smart® Alarm
Printed in U.S.A.
OIL SMART® PLUG AND PLAY SYSTEM
Technical Specifications:
Single Phase: 120VAC
OSS-100 0-16.0 FLA
Models Pump Full Load Amp Rating
• Panel Enclosure: type 3R enclosure• Liquid Smart® enclosure: type 3R high
impact injected plastic• Liquid Smart® technology: combination
capacitive/optic, solid-state low amp circuit• Oil Smart® control enclosure: type 3R
high impact injected plastic• Oil Smart® control technology: capacitive
type sensitive to variations in dielectricconstant of water and/or hydrocarbons.
Normal Condition (Water Only) When water comes in contact with the short (on) sensor, the pump will turn on. The pump will remain on until water clears the long (off) sensor.
Oil Present Condition If oil comes in contact with the (on) sensor, the pump will not turn on.
Water (Oil Present Condition) If the water level rises enough to contact the (on) sensor under the oil layer, the pump will turn on and remain on until the (off) sensor clears of water.
OPERATION OF OIL SMART®
OSS-100
www.seewaterinc.com951.487.8073 • 888.733.9283 • [email protected]
22220 Opportunity Way, Suite 101 • Riverside, CA 92518