4
Z1.10.105 ZM3045 0518 Supersedes New R Certified to CSA Standard C22.2 No.108. ** © Copyright 2018 Zoeller ® Co. All rights reserved. ELECTRICAL DATA PUMP NET WEIGHT: lbs (kg) 37 lbs (16.8 kg) MOTOR TYPE: SUBMERSIBLE SERVICE FACTOR: 1.15 POWER CORD LENGTH: ft (m) 230V= SOOW 115V= SJOOW 20' (6.1m) _____' MOTOR DESIGN LETTER: NEMA B MOTOR SHAFT: AISI 1215 STEEL IMPELLER TYPE: PLASTIC STATOR INSULATION: CLASS B SQUARE RING AND COVER GASKET: VITON LEAD WIRES INSULATION: CLASS B RPM: 3450 MAXIMUM STATOR TEMPERATURE: 266 °F (130 °C) SHAFT SEAL CONSTRUCTION: STANDARD SILICON CARBIDE/ CARBON MOTOR THERMAL SHUTOFF: STANDARD THERMAL OVERLOAD SWITCH WITH AUTOMATIC RESET MAXIMUM WATER TEMPERATURE: 130 °F (54 °C) MODEL NUMBER: 6155 PUMP NAME PLATE HORSEPOWER: 1/2 HP SOLID SIZE: in (mm) 3/4" (19mm) MINIMUM HEAD: ft. (m) 5.0' (1.5m) MAXIMUM HEAD: ft. (m) 44' (13.4m) MAX.FLOW GPM (L/min) @ MIN. HEAD ft. (m) 77 GPM @ 5' (291 L/min @ 1.5m) DISCHARGE SIZE: VERTICAL FEMALE 1-1/2 NPT MODEL HP 115 V / 1 Ph 230 V / 1 Ph FLA LRA FLA LRA 6155 1/2 10.5 17.1 5.3 8.6 FLORIDA HYDRONICS 813-918-5433 PERFORMANCE DATA COMMERCIAL EFFLUENT PUMPS MODEL 6155 GENERAL DATA visit our web site: CarlosRivera.org Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.

PERFORMANCE DATA - Carlos Rivera ZOELLER N155 OIL...OIL SMART® PLUG AND PLAY SYSTEM Printed in U.S.A. C281-REV-0116 The Oil Smart® OSS-100 System, when combined with a manual sump

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • Z1.10.105ZM3045

    0518Supersedes

    New

    R

    Certified to CSAStandard C22.2 No.108.

    **

    © Copyright 2018 Zoeller® Co. All rights reserved.

    ELECTRICAL DATA

    PUMP NET WEIGHT: lbs (kg) 37 lbs (16.8 kg) MOTOR TYPE: SUBMERSIBLE

    SERVICE FACTOR: 1.15 POWER CORD LENGTH: ft (m) 230V= SOOW 115V= SJOOW 20' (6.1m) _____'

    MOTOR DESIGN LETTER: NEMA B MOTOR SHAFT: AISI 1215 STEEL

    IMPELLER TYPE: PLASTIC STATOR INSULATION: CLASS B

    SQUARE RING AND COVER GASKET: VITON LEAD WIRES INSULATION: CLASS B

    RPM: 3450MAXIMUM STATOR

    TEMPERATURE:266 °F (130 °C)

    SHAFT SEAL CONSTRUCTION: STANDARD SILICON CARBIDE/ CARBON

    MOTOR THERMAL SHUTOFF: STANDARD THERMAL OVERLOAD SWITCH WITH AUTOMATIC RESET

    MAXIMUM WATER TEMPERATURE: 130 °F (54 °C)

    MODEL NUMBER: 6155

    PUMP NAME PLATE HORSEPOWER: 1/2 HP

    SOLID SIZE: in (mm) 3/4" (19mm)

    MINIMUM HEAD: ft. (m) 5.0' (1.5m)

    MAXIMUM HEAD: ft. (m) 44' (13.4m)

    MAX.FLOW GPM (L/min) @ MIN. HEAD ft. (m)

    77 GPM @ 5' (291 L/min @ 1.5m)

    DISCHARGE SIZE: VERTICAL FEMALE 1-1/2 NPT

    MODEL HP 115 V / 1 Ph 230 V / 1 Ph

    FLA LRA FLA LRA

    6155 1/2 10.5 17.1 5.3 8.6

    FLORIDA HYDRONICS 813-918-5433

    PERFORMANCE DATA COMMERCIAL EFFLUENT PUMPS

    MODEL 6155

    GENERAL DATA

    visit our web site: CarlosRivera.org

    Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.

    Carlos RiveraHighlight

    Carlos RiveraHighlight

    Carlos RiveraHighlight

  • SELECTION GUIDE

    1. Single or Double piggyback variable level float switch pumpcontrol using the 15 amp plug and receptacle. Refer to ZM1536.

    2. Single piggyback variable level float switch, hard wiring thepump lead wires to the float switch leads.

    3. Refer to ZM1342 and select the correct simplex control panellisted for the pump. Refer to ZM1536 and select the desiredvariable level control switch, 3 required.

    4. Refer to ZM1342 and select the correct duplex control panel listedfor the pump. Refer to ZM1536 and select the desired variablelevel control switch, 3 or 4 required.

    FEATURES

    • Motor - 1/2 HP, 60 Hz, 3450 RPM, 1 PH, oil filled, hermetically sealed,automatic reset, thermal overload protected (1 PH)

    • Lower ball bearing• Motor shaft - AISI 1215 STEEL• Mechanical shaft seal silicon carbide/carbon• Viton O-ring seal and cover gasket• Impeller - engineered thermoplastic• 20' foot neoprene cord with plug• No screens to clog• Stainless steel screws, bolts and handle• 1-1/2" NPT discharge• Corrosion resistant powder coated epoxy finish• 100% computerized tested

    CAUTIONAll installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).

    For additional information on Zoeller products refer to catalog for; Rail Systems, ZM1347; Float Switch Brackets, ZM1328; Check Valves, ZM1348; Single Phase Controls, ZM1377; Three phase controls, ZM1342 and ZM1343; High Water Alarm Panels and Float Switches, ZM1536; Control Panels, ZM1342.

    * Molded Plug ** Pumps are available with optional moisture sensors. Seal Fail indicator light available

    in NEMA 4X control panels.

    1-1/2" NPT

    3-7/8" (98 mm)

    3-7/8" (98 mm)

    4-5/8"

    6-7/32"

    3-7/8" (98 mm)

    5-3/8" (137 mm)

    12-1/8" (308 mm)

    (158 mm)

    (117 mm)

    SK2064

    014500

    © Copyright 2018 Zoeller® Co. All rights reserved.

    MODELFeet

    Shut-off Head:

    6155Meters Gal. Liters

    291771.551015

    3.04.6

    7061

    265231

    2025

    6.17.6

    5242

    197159

    3035

    9.110.7

    3322

    12583

    40 12.2 11 4244 ft.(13.4m)

    TOTAL DYNAMIC HEAD/FLOWPER MINUTE

    EFFLUENT AND DEWATERING

    Models

    Control Selection (See Selection Guide)

    Listings

    Volts Ph AmpsSim-plex

    Du-plex

    UL CSA

    *N6155 115 1 10.5 1,2 or 3 4 no yes*E6155 230 1 5.3 1,2 or 3 4 no yes

    014500

    PUMPPERFORMANCE

    CURVEMODEL 6155

    0

    104

    20

    830

    12 40

    50

    0

    20

    80 160

    40 60

    240

    80

    LITERS

    GALLONS

    FLOW PER MINUTE

    TOTA

    L DY

    NA

    MIC

    HEA

    D

    MET

    ERS

    FEET

    Carlos RiveraHighlight

  • OIL SMART® PLUG AND PLAY SYSTEM

    Printed in U.S.A. C281-REV-0116

    The Oil Smart® OSS-100 System, when combined with a manual sump pump, will automatically pump water without the risk of pumping oil into the environment. The system will alert in the event of a high oil or high water condition. Installation of the OSS-100 allows you to comply with Elevator Code ASME A17.1 and State/Federal regulations while reducing the risk of adverse publicity, fines and expensive cleanup costs.

    • Plug & play for easy installation• 120VAC, single phase, 60 hz.• Includes Oil Smart® pump control (OSS20PBPR6)

    with 20′ cord and piggyback plug• Includes Oil Smart® alarm (OSA-05) with 10′ power

    cord and Liquid Smart® sensor with 20′ cord• Pump control and alarm components differentiate

    between oil and water• Alarm visible indicators: red beacon alarm light,

    yellow light for oil, white light for water, alarm testand silence buttons

    • Alarm horn sounds at 85 decibels at 10 feet• Remote monitoring dry contacts: oil, water and high

    liquid• Panel and controls: UL listed for the United States

    and Canada

    Overview:

    Features:

    Applications:

    • Elevator sumps• Electric utilities (substations, power plants,

    underground vaults, and transformer barriers)• Manufacturing facilities• Any application where there is a need to remove

    water while containing oil

  • SEEWATER, Inc.

    OIL WATER

    Oil Smart® High Liquid Alarm System

    Patent No. 7,492,272, 7,830,268SILENCE TEST

    PUMP STOP

    PUMP START

    HIGH LIQUID ALARM

    Oil Smart® Pump Switch

    Oil Smart® Alarm

    Printed in U.S.A.

    OIL SMART® PLUG AND PLAY SYSTEM

    Technical Specifications:

    Single Phase: 120VAC

    OSS-100 0-16.0 FLA

    Models Pump Full Load Amp Rating

    • Panel Enclosure: type 3R enclosure• Liquid Smart® enclosure: type 3R high

    impact injected plastic• Liquid Smart® technology: combination

    capacitive/optic, solid-state low amp circuit• Oil Smart® control enclosure: type 3R

    high impact injected plastic• Oil Smart® control technology: capacitive

    type sensitive to variations in dielectricconstant of water and/or hydrocarbons.

    Normal Condition (Water Only) When water comes in contact with the short (on) sensor, the pump will turn on. The pump will remain on until water clears the long (off) sensor.

    Oil Present Condition If oil comes in contact with the (on) sensor, the pump will not turn on.

    Water (Oil Present Condition) If the water level rises enough to contact the (on) sensor under the oil layer, the pump will turn on and remain on until the (off) sensor clears of water.

    OPERATION OF OIL SMART®

    OSS-100

    www.seewaterinc.com951.487.8073 • 888.733.9283 • [email protected]

    22220 Opportunity Way, Suite 101 • Riverside, CA 92518