The ul�mate solu�on for a refreshingly cool space
COOLING ONLY [60Hz], 220V
Per fec t ing t he Ai r
Non-Inver ter
WORLD’s
AIRCONDITIONINGCOMPANY
YEARSWARRANTY5
COMPRESSOR
JapanQuality YEAR
WARRANTY1 PARTS & LABOR
Outdoor unit
Indoor unit
RR100AGXVLRR125/140AGXTL9
RR71AGXVLRR50/60AGXVL
Durability• The unit is covered with corrosion-proof galvanized steel to enhance its durability.• Heat exchange �ns are provided with anti-corrosion treatment.
Fitted with wide inlet fan
Wide inlet fan
Pre-charged for up to 7.5 metresModel Max. piping length, m Max. piping elevation, m
RR50A
RR60A
RR71A
RR100ARR125ARR140A
30
50
50
15
25
30
Fully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence.
FHRN100AXVL/140AXVL9Ceiling Suspended
4HP / 6HP
FVRN71/100AXVL/125/140AXVL9Floor Standing
3HP / 4HP / 5HP / 6HP
FCRN50/60/71/100AXVL/125AXVL92HP / 2.5HP / 3HP / 4HP / 5HP
Ceiling Cassette
2HP / 2.5HP / 3HP / 4HP / 5HP / 6HP
Duct ConnectionFDMRN50/60/71/100AXVL/125/140AXVL9
Standard Static Pressure Type
Non-Inver ter
Work & ServicingDrain pump mechanismPre-charged for up to 7.5mSelf-Diagnosis
OptionalGroup control by NetworkInterface Module (NIM)
External command control using BAG
Wired Remote Controller
ComfortAuto-swingSwing PatternSwitchable fan speedProgramme “Dry”
Timer SelectorTwo selectable temperature sensor*
* Applicable when wired controller is used
Weekly scheduled timer*
Ceiling Suspended
FHRN140AXVL9
RR140AGXTL9
56,000
16.41
6,240
18.8
3/220/60
COP 2.63
Air Flow Rate (H/M/L) 1550/1380/1000
Sound Pressure Level (H/M/L) 56/54/51
Dimension (H x W x D)
Machine Weight 70
Sound Pressure Level 66
Dimension (H x W x D)
Machine Weight 101
Pipe Connection-Liquid
Pipe Connection-Gas
FHRN100AXVL
RR100AGXVL
35,000
10.26
3,800
17.3
1/220/60
2.70
1107/999/751
49/46/43
52
61
71
15.9 19.05
Indoor Unit
Outdoor Unit
Btu/hr
kW
Watts
A
Ph/V/Hz
W/W
cfm
dBA
mm
Kg
dBA
mm
Kg
mm
mm
Model Name
Power Supply
Rated Cooling Capacity (Min. ~ Max.)
Power Consumption
Total Running Current
OUTDOOR
INDOOR
9.5
235 x 1,903 x 680 285 x 1,903 x 680
852 x 1,030 x 400
mMinimum Piping Length 3 5
FHRN140AXVL9
RR140AGXTL9
50
50
FHRN100AXVL
RR100AGXVL
7.5
30
30
Indoor Unit
Outdoor Unit
m
g/m
Model Name
Chargeless Refrigerant
mMaximum Piping Elevation
mMaximum Piping Length
Additional RefrigerantCharge
CleanlinessWashablesaranet filter
Control FeaturesAuto random restart
Work & ServicingDrain pump mechanismPre-charged for up to 7.5mSelf-Diagnosis
OthersAnti-corrosion treatedheat exchangers
OptionalFresh-air intake kitGroup control by Network Interface Module (NIM)External command control using BAGWired Remote Controller
Ceiling CassetteComfort
Auto-swingSwing PatternSwitchable fan speedProgramme “Dry”Timer Selector
Two selectable temperature sensor
*
* Applicable when wired controller is used
Weekly scheduled timer*
Indoor Unit FCRN50AXVL FCRN125AXVL9
Outdoor Unit RR50AGXVL RR125AGXTL9
Btu/hr 18,500 48,000
kW 5.42 14.07
Watts 1,730 5,100
A 7.9 14.8
Ph/V/Hz 3/220/60
COP W/W 3.13 2.76
22 10 24
Air Flow Rate (H/M/L/Q) cfm 730/620/510/360
Sound Pressure Level (H/M/L/Q) dBA 39/35/33/29 49/46/42/38
Deco Panel (H x W x D) mm
Machine Weight Kg
Sound Pressure Level dBA 66
Dimension (H x W x D) mm
Machine Weight Kg 87
Pipe Connection-Liquid mm
Pipe Connection-Gas mm 12.7
m
m
m
OUTDOOR
Maximum Piping Length
Minimum Piping Length
Maximum Piping Elevation
Power Supply
Model Name
Rated Cooling Capacity (Min. ~ Max.)
Power Consumption
Total Running Current
1/220/60
INDOOR
43
15
30
651 x 855 x 328
50
6.4
Unit Dimension (H x W x D) mm
Decorative Panel
m
g/m
Chargeless Refrigerant
Additional Refrigerant Charge
FCRN71AXVL
RR71AGXVL
29,500
8.65
3,130
14.3
2.76
890/760/620/490
43/41/36/34
57
753 x 855 x 328
57
25
3
BC50F2XWA
7.5
30
15.9
30
1120/1030/890/760
343 x 950 x 950
30
852 x 1030 x 400
FCRN100AXVL
RR100AGXVL
36,000
10.55
3,700
16.8
2.85
48/45/41/37
61
71
50
9.5
288 x 840 x 840
FCRN60AXVL
RR60AGXVL
24,000
7.03
2,400
11
2.93
840/700/560/440
41/38/35/32
301 x 950 x 950
27
246 x 840 x 840
Non-Inver ter
ComfortSwitchable fan speed
Programme “Dry”
Timer Selector* Applicable when wired controller is used
Two selectable temperature sensor
*
Weekly scheduled timer*
CleanlinessWashablesaranet filter
Control FeaturesAuto random restart
Work & ServicingPre-charged for up to 7.5m
Self-Diagnosis
OthersAnti-corrosion treatedheat exchangers
OptionalGroup control by Network Interface Module (NIM)
External command control using BAG
Wired Remote Controller
Duct ConnectionStandard Static Pressure Type
Indoor Unit FDMRN50AXVL FDMRN60AXVL
Outdoor Unit RR50AGXVL RR60AGXVL
Btu/hr 18,500 23,500kW 5.42 6.89
Watts 1,730 2,400
A 7.9 11
Ph/V/Hz
COP W/W 3.13 2.87
Air Flow Rate(H/M/L) cfm 590/520/320 690/570/440 1580/1330/1180
External Static Pressure Pa
Sound Pressure Level(H/M/L) dBA 40/38/33 42/40/39
Dimension (H x W x D) mm 261 x 1,065 x 411 261 x 1,200 x 411
Machine Weight Kg 24 26
Sound Pressure Level dBA
Dimension (H x W x D) mm
Machine Weight KgPipe Connection-Liquid mm
Pipe Connection-Gas mm 12.7
m
m
m
FDMRN71AXVL
RR71AGXVL
29,0008.5
3,330
15.3
2.55
900/830/640
47/45/42
378 x 999 x 541
42
57
753 x 855 x 328
57
3
25
Total Running Current
Power Supply 1/220/60
Model Name
Rated Cooling Capacity (Min. ~ Max.)
Power Consumption
INDOOR
Maximum Piping Length
Minimum Piping Length
Maximum Piping Elevation
100
9.5
50
OUTDOOR
FDMRN125AXVL9
RR125AGXTL9
48,00014.075,520
15.6
1540/1280/1100
51/48/46
378 x 1,369 x 541
50
87
3/220/60
66
2.55
30
852 x 1030 x 400
30
15
50
6.4
50
651 x 855 x 328
43
m
g/m 10
Chargeless Refrigerant
Additional Refrigerant Charge 24
FDMRN140AXVL9
RR140AGXTL9
56,00016.416,590
19.5
52/50/47
378 x 1,569 x 541
56
5
101
19.05
2.49
5022
FDMRN100AXVL
RR100AGXVL
36,00010.554,000
18.2
2.64
1250/980/780
50/47/43
378 x 1,115 x 541
44
61
71
30
15.9
7.5
CleanlinessWashable saranet filter
Work & ServicingPre-charged for up to 7.5m
Self-Diagnosis
Control FeaturesAuto random restart
OthersAnti-corrosion treatedheat exchangers
Comfort
Switchable fan speed
Programme “Dry”
Timer Selector * Applicable when wired controller is used
Two selectable temperature sensor
*
Weekly scheduled timer*
Horizontal Auto-swing
Floor Standing
Indoor Unit FVRN71AXVL
Outdoor Unit RR71AGXVL
Btu/hr 29,000
kW 8.5
Watts 3,130
A 13.7
Ph/V/Hz
COP W/W 2.72
Air Flow Rate (H/M/L) cfm 675 / 625 / 530
Sound Pressure Level (H/M/L) dBA 44 / 42 / 39
Dimension (H x W x D) mm 1,850 x 600 x 270
Machine Weight Kg 42
Sound Pressure Level dBA 57
Dimension (H x W x D) mm 753 x 855 x 328
Machine Weight Kg 57
5
Pipe Connection-Liquid mm
Pipe Connection-Gas mm
m
m 25
Maximum Piping Length
mMinimum Piping Length
Model Name
Power Supply
Total Running Current
Rated Cooling Capacity (Min. ~ Max.)
Power Consumption
INDOOR
Maximum Piping Elevation
OUTDOOR
1/220/60
9.5
50
3/220/60
66
FVRN125AXVL9
RR125AGXTL9
48,000
14.07
5,000
14.5
2.81
1035 / 935 / 835
50 / 48 / 46
48
87
30
1,850 x 600 x 350
852 x 1030 x 400
FVRN140AXVL9
RR140AGXTL9
56,000
16.41
6,240
18.8
2.63
1170 / 1085 / 985
54 / 53 / 51
51
50
101
19.05
m
g/m 30 30 24
Chargeless Refrigerant
Additional Refrigerant Charge
7.5
FVRN100AXVL
RR100AGXVL
36,000
10.55
3,800
17.3
2.78
1035 / 945 / 845
49 / 47 / 44
45
61
71
3
15.9
Non-Inver ter
Controller
Wired controller BRC51A621
2
6
789
11
10
3
4
5
Wireless controller BRC52A62
1
2
3
5
6
789
10
11
4
Auto-swing (Not applicable
for Suspended type)
Selectable mode:
Cool, Dry, Fan
7
Turbo function8
Quiet function9
On timer setting10
Real time clock11
61
3
4
5
2 Fan speed selection:
Low, Medium, High, Auto
Temperature setting:
Up & down
Sleep mode function
“Glow-in-the-dark”
on / off switch
Off timer setting
Wired controller BRC51A62 can directly be connected to the unit’s main board to start operating without extra setting or modi�cation. It also has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort (no settings required to activate the handset temperature sensor).
IR receiver on wired handsetreceived the signal
Signal sent fromwireless handset
2 Temperature operate
in ˚C and ˚F3 Swing function
4 Sleep mode function
1 Real time clock and
day display Turbo function7
Cool, Dry, Fan mode8
Delay timer (1 or 2 hours)9
7-days programmable timer10
On / Off Switch6
11 Low, Medium, High,
Auto fan speed
5 Sleep function
● Speci�cations, designs, and other content appearing in this brochure are current as of June 2020 but subject to change without notice.● 1 year warranty for parts and labor | 5 years warranty for compressor only (Labor and Consumables are chargeable after 1 year).
www.daikin.com.ph
Authorized DealerTel No.: (02) 5318 - 6800 | Customer Service: (02) 5318 - 6820
Branches:ILOCOS Tel No.: (077) 600 - 2720DAGUPAN Tel No.: (075) 615 - 2791NAGA Tel Fax: (054) 871 - 4177
ILOILO Tel Fax: (033) 323 - 2340CEBU Tel No.: (032) 348 - 0085CDO Tel Fax: (088) 868 - 6800DAVAO Tel Fax: (082) 285 - 6008
[email protected] Daikin Philippines
DPH-SANINV-062020D
Network Controls
Group control by NetworkInterface Module (NIM)
For simultaneous controlof up to 16 indoor units
For sequential control of 2 indoor units at alternatesequence of pre-set hour
Operation and surveillanceis carried out using thecontact signal from theoperation control box inthe building surveillance(security) room.
Sequential control bySequential Network
Interface Module (S-NIM)
Control by externalcommand using BAG
Control Pattern Remote Controls
S-NIM S-NIM
BAG
BMS
BAG BAG
NIM NIM NIM NIM