7
Page: 1 15.02.2012 18-1120_Bitumen.pdf data & photo not mandatory Penetration - Bitumen Method - PNR 12 (automatic) Standards depend on the selected accessories ASTM D 5, DIN 52010 (obs.), EN 1426, EN 13179-2, EN 13880-2, JIS K2207, AASHTO T49 Product group(s): Bitumen, Penetration User group(s): Airports & Aviation, Asphalt, Bitumen, Mastics, Penetration, Regulatory Authorities, Road Research, Tar, Various Scope: The Penetrometer PNR 12 is suitable for measurements according various "Bitumen" methods. Needle-Penetration: To measure the consistancy of semi-solid and solid bituminous mixtures. Rod-Penetration: To measure the apparent viscosity (Bitumen No) of filler aggregates used in bituminous mixtures. Cone-Penetration: To determinate the consistancy of hot-applied, fuel-resistant joint sealants with or with out being immersed in fuel or oil. The Penetration is used to measure the resistance which a material under specified test conditions provides against being pierced by a specifically shaped penetrator. Beside the configuration of the penetrator used, prime importance attaches to such factors as temperature, time and load specified by the different standard methods of test. Fully "Automatic Surface-Detection" Jog-Shuttle driven menue (turn & push) Manual & electronic positioning Movement by stepper motor LED illumination PNR 12 allows fully automatic measurements on electrically conductive samples, as well as on non-conductive samples with the optional patented Force-Sensor-Plunger. The Surface-Detection Software of the PNR 12 will be activated by Force-Sensor-Plungers. This option will detect the surface of non-conductive samples, even underneath a layer of water, It starts the standardized test sequence and reports the results automatically. PNR 12 - Automatic Penetrometer Depending on accessories suitable for: • Needle-Penetration • Cone-Penetration • Rod-Penetration • and further applications Accessories (plungers, needles etc.) are required, but not included. All test kits that fit the PNR 10 & 21 models are suitable for the PNR 12, too. (Except for the Ball-Penetration Method) More details are mentioned in the "Order Number" section Technical Data Measuring Range: 0 to 80 mm Max. Test Load: 2 kg Resolution: 0.01 mm Test Duration: 0.1 to 18000 seconds (preset standard duration: 5 seconds) Start Delay: adjustable up to max. of 600 sec. (10 minutes) Value Conversion: NLGI-class, EN-bitumen value, c-value, 1/4-cone to solid-cone, 1/2-cone to solid-cone Surface Detector: for electrically conductive samples (optional for non-conductive samples) Data Output: USB interface to connect printer or USB-stick Bench space: (WxHxD) 350 x 350 x 600 mm Weight: 11 kg

Penetration - Bitumen Method - PNR 12 (automatic) · Penetration - Bitumen Method - PNR 12 (automatic) Standards depend on the selected accessories ASTM D 5, DIN 52010 (obs.), EN

  • Upload
    others

  • View
    28

  • Download
    1

Embed Size (px)

Citation preview

Page: 115.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

Penetration - Bitumen Method - PNR 12 (automatic)Standards depend on the selected accessories

ASTM D 5, DIN 52010 (obs.), EN 1426, EN 13179-2, EN 13880-2, JIS K2207, AASHTO T49

Product group(s): Bitumen, Penetration

User group(s): Airports & Aviation, Asphalt, Bitumen, Mastics, Penetration, Regulatory Authorities, Road Research, Tar,Various

Scope: The Penetrometer PNR 12 is suitable for measurements according various "Bitumen" methods.

Needle-Penetration:To measure the consistancy of semi-solid and solid bituminous mixtures.

Rod-Penetration:To measure the apparent viscosity (Bitumen No) of filler aggregates used in bituminous mixtures.

Cone-Penetration:To determinate the consistancy of hot-applied, fuel-resistant joint sealants with or with out being immersed infuel or oil.

The Penetration is used to measure the resistance which a materialunder specified test conditions provides against being pierced by aspecifically shaped penetrator.

Beside the configuration of the penetrator used, prime importanceattaches to such factors as temperature, time and load specified bythe different standard methods of test.

Fully "Automatic Surface-Detection"

Jog-Shuttle driven menue (turn & push)

Manual & electronic positioning

Movement by stepper motor

LED illumination

PNR 12 allows fully automatic measurements on electricallyconductive samples, as well as on non-conductive samples with theoptional patented Force-Sensor-Plunger.

The Surface-Detection Software of the PNR 12 will be activatedby Force-Sensor-Plungers. This option will detect the surfaceof non-conductive samples, even underneath a layer of water,It starts the standardized test sequence and reports the resultsautomatically.

PNR 12 - Automatic Penetrometer

Depending on accessories suitable for:

• Needle-Penetration • Cone-Penetration• Rod-Penetration • and further applications

Accessories (plungers, needles etc.) are required, but not included.All test kits that fit the PNR 10 & 21 models are suitable for the PNR 12, too.(Except for the Ball-Penetration Method)

More details are mentioned in the "Order Number" section

Technical DataMeasuring Range: 0 to 80 mmMax. Test Load: 2 kgResolution: 0.01 mmTest Duration: 0.1 to 18000 seconds

(preset standard duration: 5 seconds)Start Delay: adjustable up to max. of 600 sec. (10 minutes)Value Conversion: NLGI-class, EN-bitumen value, c-value,

1/4-cone to solid-cone, 1/2-cone to solid-coneSurface Detector: for electrically conductive samples

(optional for non-conductive samples)Data Output: USB interface to connect printer or USB-stickBench space: (WxHxD) 350 x 350 x 600 mmWeight: 11 kg

Page: 215.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

Main Unit

18-1120 PNR 12 - Automatic PenetrometerFor numerous test methods and applications.Accessories have to be selected according to the standard. (Suitable for: Needle-, Cone-, Rod-Penetration and further methods)

Features: • manual positioning by Jog-Wheel operation • electronic positioning to a preset depth with Memory-function • automatic surface detection • fully automatic measurements of electrically conductive samples • fully automatic measurements of non-conductive samples (optional) • automatic data evaluation against limit values set • auto-start function • 16 user programs possible • magnifier & extra bright LED-sample illumination

Consisting of:Microcomputer, graphical display, electronic distance measuring device, stepper motor for exactpositioning, conductivity sensor, plastic housing with stable base plate and software for fully automaticmeasurements of electrically conductive samples, as well as of non-conductive samples using theoptional patented Force-Sensor-Plunger.

Microcomputer:Microprocessor with FPGA for real-time measurement, large display (blue / white), intuitive Jog-Wheeldriven graphical menu (turn & push), help and guide functions, data-management via LAN and USB,LIMS compatibility, statistics and database function, automatic data evaluation against limit values set.

Interface:USB for keyboard, printer and stick, LAN for data transfer to PC. Easy firmware-update via USB.

Software:- Auto-Start function for program 1+2+3- 16 program positions for user defined programs

- Automatic surface detection: • by conductivity sensor (included) • with force sensor (Requires a Force-Sensor-Plunger - not included)

- Conversion of results: • NLGI-classification ASTM D 217 • Bitumen classification EN 1426 • Quarter- and Half-Scale Cone into Full-Scale Cone • Margarine C-value 80g and 160g

Electronic Elements:Distance measuring device (1/100 mm), stepper motor, LED-sample illumination with flexible arm,electronic detector for conductive samples (conductivity sensor), PT-100 receptacle for temperaturelogging.

Mechanical Elements:Penetrometer base plate with leveling feet and removable aluminum test table, instrument housingmade of plastics, magnifier with flexible arm, plunger holder with solenoid release mechanism for testbodies up to 2 kg.

Supplied with:1 conductivity sensor, 1 Leveling bulb

Note - To be ordered separately: Accessories in compliance with different test standards or samples (plunger, needle, cone etc.)Recommended extensions: force-sensor plunger, temperature-sensor PT-100, calibration-set, keyboard

Power supply: 100/240 V, 50/60 Hz

Page: 315.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

18-2220 Test Kit "Needle - ASTM"ASTM D 5 - AASHTO T49 - JIS K2207

Suitable for: bituminous materials, chocolate, compact powder, lipstick, soap, yeast

Consisting of: 3 standard needles, 2.5 g, brass/steel, precision made (18-1160) 1 plunger 47.5 g (18-0042) 1 load weight 50 g (18-0051) 5 sample jars I, Ø 55 x 35 mm (18-0066) 1 tempering bath (18-0065)1 petri dish, Ø 43 x 11 mm (13-0514)

18-2221 Test Kit "Needle - EN"EN 1426 (IP 49 obs.)

Suitable for: bituminous materials, chocolate, compact powder, lipstick, soap, yeast

Consisting of: 3 standard needles 2.5 g, brass/steel, precision made (18-1160) 1 plunger 47.5 g (18-0042) 1 load weight 50 g (18-0051) 5 sample jars I, Ø 55 x 35 mm (18-0066) 1 sample jar III, Ø 70 x 45 mm (18-0068) 1 sample jar V, Ø 55 x 60 mm (18-0069) 1 reduction ring Ø 36 / 53 x 20 mm (18-0076) 1 reduction ring Ø 36 / 53 x 30 mm (18-0077) 1 tempering bath with serpentine heat exchanger tube (18-0070) 1 intermediate bottom (18-0091) 1 thermometer holder (18-0094) 1 thermometer ASTM 63C (90-0106) 1 thermometer ASTM 64C (90-0107)

Note! for standard acc. to IP 49 obs. is required: 150g load weights (18-0052 & 18-0056) and thermometer ASTM 17C (21-0601).

18-2222 Test Kit "Needle - manually <350 PU"

ASTM D 5 (<350 PU) - EN 1426 (<330 PU)

Suitable for: Bitumenwith an expected immersion depth of less than 35 mm

Consisting of:3 standard needles 2.5 g, brass/steel, precision made (18-1160)1 plunger 97.5 g (18-0050)3 sample jars I, Ø 55 x 35 mm (18-0066)1 sample jar III, Ø 70 x 45 mm (18-0068)1 tempering bath (Ø 160 x 80 mm) with serpentine heat exchanger tube (18-0070)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 thermometer ASTM 63C (90-0106)

Note! for manual surface detection with PNR 12

Page: 415.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

18-2223 Test Kit "Needle - automatic <160 PU"

ASTM D 5 (<160 PU) - EN 1426 (<160 PU)

Suitable for: Bitumenwith an expected immersion depth of less than 16 mmafter 5 seconds with 100 g weight

Consisting of:3 standard needles 2.5 g, brass/steel, precision made (18-1160)1 sensor plunger 97.5 g (18-1136)3 sample jars I, Ø 55 x 35 mm (18-0066)1 tempering bath (Ø 160 x 80 mm) with serpentine heat exchanger tube (18-0070)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 temperature sensor PT-100 (18-1149)

Note! for automatic surface detection with PNR 12 only!

18-2224 Test Kit "Needle - manually >330 PU"

ASTM D 5 (>350 PU) - EN 1426 (>330 PU)

Suitable for: Bitumenwith an expected immersion depth of more than 33 mm

Consisting of:3 long standard needles 2.5 g, brass/steel, precision, (18-9994)1 plunger 97.5 g (18-0050)3 sample jars I, Ø 55 x 70 mm (18-0075)1 tempering bath (Ø 160 x 80 mm) with serpentine heat exchanger tube (18-0070)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 thermometer ASTM 63C (90-0106)

Note! for manual surface detection with PNR 12

18-2225 Test Kit "Needle - automatic <160 PU modified"

ASTM D 5 (<160 PU)

Suitable for: modified Bitumenwith an expected immersion depth of less than 16 mmafter 60 seconds with 200 g weight

Consisting of:3 standard needles 2.5 g, brass/steel, precision made (18-1160)1 sensor plunger 97.5 g (18-1136)1 load weight, 100 g (18-1201)3 sample jars I, Ø 55 x 35 mm (18-0066)1 tempering bath (Ø 160 x 80 mm) (18-0065)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 temperature sensor PT-100 (18-1149)

Note! for automatic surface detection with PNR 12 only!

18-2370 Test Kit "Ram - Bitumen Number" (van der Baan)EN 13 179-2

Suitable for: bitumen

Consisting of: 1 ram Ø 8 mm, 15 g, aluminum (18-0251) 1 sample jar Ø 30 mm x 30 mm (18-0252)

Page: 515.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

18-2215 Test Kit "Optional Hollow Cone - Filler"ASTM D 5329 - EN 13 880-2

Suitable for: Sealant, Fillers

Consisting of: 1 optional hollow cone 102.5 g, brass/steel (18-0101) 1 plunger 47.5 g (18-0042) 1 sample jar I, Ø 55 x 35 mm (18-0066) 1 tempering bath (18-0065) 1 spacer plate for tempering bath (18-0091)

Options & Accessories

18-1160 Standard Needle, 2.5 g (precision made)ASTM D 5 - EN 1426 - JIS K2207 (lP 49 obs.) and other applications

made of brass / stainless steel

18-1161 Standard Needle, 2.5 g (factory certified)ASTM D 5 - EN 1426 - JIS K2207 (lP 49 obs.) and other applications

made of brass / stainless steel

18-1163 Standard Needle, 2.5 g (officially certified)EN 1426 (lP 49 obs.)

made of brass / stainless steel

18-1164 Standard Needle, 2.5 g (officially certified)ASTM D 5 (suitable for EN 1426 and lP 49 obs.)

made of brass / stainless steel

18-1135 Sensor-Plunger - Force 47.5 g (PNR 12 only)1 load weight of 2/5/10/50 or 100 g can be added.

(Same like 18-1136)

18-1136 Sensor-Plunger - Force 97.5 g (PNR 12 only)1 load weight of 2/5/10/50 or 100 g can be added.

A plunger with an extremely sensitive force sensor for the automatic surface detection underneath alayer of water. It activates the related the PNR 12 software automatically.

Suitable for Bitumen-samples <160 PU!

18-1137 Sensor-Plunger - Force 97.5 g extra long (PNR 12 only)Up to 4 load weights of 2/5/10/50 or 100 g can be added.

(Same like 18-1136)

18-1200 Additional Weight for Sensor-Plunger, 50 g

18-1201 Additional Weight for Sensor-Plunger, 100 g

18-1202 Additional Weight for Sensor-Plunger, 10 g

18-1203 Additional Weight for Sensor-Plunger, 5 g

18-1204 Additional Weight for Sensor-Plunger, 2 g

Page: 615.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

18-1145 Calibration Kit - PNR 12for calibration of distance, time and temperature

Supplied with:for distance calibration: 1 test ram & 4 gauge blocks (5 / 9 / 15 & 25 mm)

for time calibration: 1 contact-rod & 1 stop watch (electric input)

for temperature calibration: 2 reference-plug (+20°C & +90°C)optional order: 21-0662 thermometer ASTM D 63C, officially certified

25-0911 Keyboard - english layout86 keys (no numeric block), black housing & keys, incl. adapter (USB socket on PS/2 plug)Dimensions approx.: 282 x 132 x 26 mm, 400 g, cable length 1.75 m

18-1144 Electronic Stop Watch with electric start-inputPower supply: 100/240 V, 50/60 Hz

25-0282 Impact Printer (mono)for single sheets & continuous paper to record data like test results, duration of test, etc. (instead of a PC)

Supplied with: 2 data cables (9-pin 25-0304, USB 25-0918), 1 ink ribbon (black)

Technical Data:Line spacing: 80 characters per line (10 cpi)Page size : 257 x 364 mm (sheet), 254 x 558.8 mm (roll)Ports: serial (9-pin), USB (1.1)Dimensions: 37 x 28 x 16 cm (WxDxH)Weight: 5 kgPower supply: 220/240 V, 50/60 Hz

25-0284 Ink Ribbon, black, for serial impact printer

18-0712 Halogen Desk Lampextra bright, to be placed beside the penetrometer; highly recommended if testing bituminous materials under water surface

Power supply: 230 V, 50 Hz

18-0715 Bulb (12 V, 20 W) for halogen desk lamp

18-1149 Temperature Sensor with PT-100to monitor the sample-bath temperature

21-0601 Thermometer ASTM 17CRange: +19 to +27 : 0.1 °C Length: 275 mm, Immersion: total, Ø 6.5 mm

21-0607 Thermometer ASTM 17C

Page: 715.02.2012

18-1120_Bitumen.pdfdata & photo not mandatory

Range: +19 to +27 : 0.1 °C (officially certified)

21-0621 Thermometer ASTM 17FRange: +66 to +80 : 0.2 °F Length: 275 mm, Immersion: total, Ø 6.5 mm

21-0627 Thermometer ASTM 17FRange: +66 to +80 : 0.2 °F (officially certified)

21-0662 Thermometer ASTM 63CRange: -8 to +32 : 0.1 °C (officially certified)

21-0663 Thermometer ASTM 64CRange: +25 to +55 : 0.1 °C (officially certified)

25-0670 Circulator-Bath Set (+5/+100)with cooling-coil, intermediate bottom, cooler and insulated hose set

Bath for direct tempering in the bath and / or for heating of small instruments without circulation pump(external tempering).Consisting of: Stainless steel bath with drain tap. Thermostat with digital display, splash-proof keypad,integrated heater, pump and over-temperature protection.

Circulation Cooler for cooling or counter cooling the circulator-bath.Consisting of: Cooler with tank, Pt100, digital display, pump and liquid level indication.

Supplied with: 1 circulator-bath (25-0672), 1 intermediate bottom (25-0674), 1 cooling-coil (25-0572), 1 insulated hose-set (Ø 8 mm, 2x 2m) (25-0228), 1 circulation cooler (25-0248)

Technical Data:Working range: +5 to +100 °C (at +5 to +40 °C ambient temp.)Display / Resolution: digital / 0.1 °C

BathHeater capacity : 2000 W Pump-Pressure capacity : 15 l/min, 350 mbarVolume: 27 lBath opening: 36 x 30 x 20 cm (WxDxH)Dimensions / Weight: 57 x 37 x 42 cm (WxDxH), 13 kg

CoolerCooling capacity: 300 W at +15°CPump-Pressure capacity: 20 l/min, 200 mbarPump-Suction capacity: 17 l/min, 180 mbarVolume: 1.4 lDimensions / Weight: 23 x 36 x 38 cm (WxDxH), 23 kg

Power supply: 230 V, 50 Hz, EU-plug

25-0671 Circulator-Bath Set (+5/+100)Like 25-0670 but:Power supply: 115 V, 60 Hz

Spare Parts

18-0705 Electronic surface detector for conductive sampleswith contact hook and connection wire

18-1146 Leveling Bulb - PNR (with pole for horizontal adjustment)

Order GuidelineMinimum equipment: 1 x 18-1120 & Test Kit (needle, cone etc.),

AccessoriesSpares (approx. 1 year): acc. to test kit: Needle or Cone, ThermometerAdditional requirements: