Underground distribution systems
Underground distribution systems with electrical socket combinations
3-6 General information
7-18 EK 800 | with swivel manhole cover
19-26 EK 600 | with swivel manhole cover
27-28 EK 602 | compact satellite power distributor
Underground distribution systems for power supply and telecommunication
29-30 EK 880 | with horizontally swivelling flood proof compartment
Underground distribution systems for customised component integration
31 EK 368 | housing with NH00 isolator
32-33 EK 838 | with integrated cable outlet in cast iron cover
34-35 EK 383 | motorway roadside emergency telephone manhole
36 References
Langmatz underground distribution systems are modern distribution systems also suitable for flood proof underground installation. We produce and deliver solutions that fit urban landscapes in the age of contemporary marketplace design.
2
3
Langmatz underground distribution systems are modern, flood proof distribution systems for
electricity, water and telecommunication lines suitable for underground installation.
They ensure solutions that fit urban landscapes in the age of contemporary marketplace design
and urban renewal.
Advantages
• Wide field of applications with different standard variants, customised electrical socket
combinations, component integration and supply media
• Reliable fixture protection against flooding thanks to flood proof compartment
• Access possible at any time in all weathers thanks to the specially patented locking system
• Protection against unauthorised access using different locking variants
• Easier and faster opening of the covers using supporting stainless steel gas springs
• Load classes up to D 400 acc. to DIN EN 124
Advantages
4
• Dirt-resistant locking mechanism with positive opening function in the
event of dirt ingress or icing
• Modular design of the electrical socket combinations
• Electrical socket combinations are integrated into flood proof submersion
hood
• Cable outlet on the left-hand and right-hand side of the locking
mechanism, independent operation
• Fresh water connections
Supply: 1”
Outlet: 1/2”
EK 600 | coupler up to 2 x 1/2 inch to 1 inch
EK 800 | coupler up to 4 x 1/2 inch to 1 inch
+ 1 x 2” waste water
• Swivel manhole cover, easily accessible due to two stainless steel gas
springs
• Clear, logical assignment of the circuit breaker/residual current device to
the sockets
• One miniature circuit breaker per socket
• Sheet metal parts produced with modern sheet metal bending technology
• Step protection
• IP68 connection housing acc. to DIN EN 60 529 with NH-00 fixture as
back-up fuse or as terminal box
• Clearly defined area for the installation of an expansion joint
• Water connection installation in the area of the optional electric heater
• Lockable
• Centred locking mechanism for optimum application of force
Product properties
5
Modular electrical socket combinations• Integrated into flood proof submersion cover• Configuration example (see configurator)
Connecting housing • IP68 acc. to DIN EN 60 529• With NH-00 back-up fuse or terminal block
Cover heater• 180 W• Thermostat
Fresh water • 2 x quick disconnect (fibre) coupler, type GK 1/2–1" (EK 600) or
4 x quick disconnect (fibre) coupler, type GK 1/2–1" (EK 800) • Fresh water KFR (combined free-flow/check valve) shut-off valve (The operating company is responsible for check valves)• Shut-off and drainage hydrant• Water meter
Waste water • Storz 52-C 2" DIN 14037 quick disconnect (fibre) couplers for waste water
Compressed air • On request
Individual configuration
6
Opening mechanism protected via separate locking flap
Locking mechanism with hexagon socket spanner for easy operation
Generously dimensioned cable outlet, for cables up to Ø 60 mm
Patented locking mechanism
Locking mechanism for underground distribution system
EK 600 | EK 800
Cable outlet and lock spring
7
Underground distribution system EK 800with swivel manhole cover
EK 800Inside width: 550 x 800 mm
Overall outer dimensions: 825 x 1050 mm
Overall height without NH-00 back-up fuse: approx. 625 or 845 mm
Overall height with NH-00 back-up fuse: approx. 1065 mm
Paveable stainless steel manhole cover and manhole frame:
up to D 400 acc. to DIN EN 124
Paving height: 65 mm
Maximum fuse protection: 100 A
Connected load of the optional electric heater:
180 W
Protection class of electric distributor:closed: IP58 acc. to DIN EN 60 529 open: IP54 acc. to DIN EN 60 529
Side view Front view Top view(paveable cover)
Area of application
Marketplace designs that fit into urban landscapes, as well as the supply of marketplaces, individual stalls and events with electricity, fresh water and more. Hidden underground and well protected against vandalism and damage. Fast and easy access by authorised personnel.
1050
954
“X”
as p
er c
on
fig
ura
tio
n
706
825
734LW 550x800
942
8
Manhole Confi gurator EK 800
Item No 70 070 8000 / 000
Change index: 4
9
4
3. Manhole body
4. Test category(please make a selection)
Man-hole height
Description Paveable cover Item No:
Chequered stud plate cover Item No:
Concrete-lined cover Item No:
Visual depiction
Hei
ght 1
= 6
25
mm
- Elec. installation kituptomax.32Asocket only for var. 1; 2; 10- No water and/or waste water possible- No main fuse and/or clamping unit possible
06 800 05011xsize220frame
06 800 0501/0011xsize220frame
06 800 0501/0021xsize220frame
Hei
ght 2
= 8
45
mm
- Electrical installa-tion kit: no restric-tions- No water and/or waste water possible- No main fuse and/or clamping unit possible
06 800 05022xsize220frame
06 800 0502/0012xsize220frame
06 800 0502/0022xsize220frame
Hei
ght 3
= 1
065
mm
No restrictions 06 800 05033xsize220frame
06 800 0503/0013xsize220frame
06 800 0503/0023xsize220frame
Test category Item No: SelectionDIN EN124-B125 06 800 0053DIN EN124-D400 06 800 0052
= Please mark requested variant
105
5. Installation, operation and maintenance guidelines(please make a selection)
Language Item No: SelectionGerman 70 070 0900 / 000English 70 070 0900 / 001
Other languages available on request.
6. Electrical installation kit (please make a selection)
Visual de-piction
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
1.1 16xSchuko4x16A5-pole0x32A5-pole
16 mm² max.80A 06 800 0301
1.2 16xSchuko3x16A5-pole1x32A5-pole
16 mm² max.80A 06 800 0302
1.3 16xSchuko2x16A5-pole2x32A5-pole
16 mm² max.80A 06 800 0303
1.4 16xSchuko1x16A5-pole3x32A5-pole
16 mm² max.80A 06 800 0304
1.5 16xSchuko0x16A5-pole4x32A5-pole
16 mm² max.80A 06 800 0305
11
6
Visual depic-tion
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
2.1 8xSchuko6x16A5-pole0x32A5-pole
16 mm² max.80A 06 800 0306
2.2 8xSchuko5x16A5-pole1x32A5-pole
16 mm² max.80A 06 800 0307
2.3 8xSchuko4x16A5-pole2x32A5-pole
16 mm² max.80A 06 800 0308
2.4 8xSchuko3x16A5-pole3x32A5-pole
16 mm² max.80A 06 800 0309
2.5 8xSchuko2x16A5-pole4x32A5-pole
16 mm² max.80A 06 800 0310
2.6 8xSchuko1x16A5-pole5x32A5-pole
16 mm² max.80A 06 800 0311
2.7 8xSchuko0x16A5-pole6x32A5-pole
25 mm² max.100A 06 800 0312
3.1 8xSchuko2x16A5-pole0x32A5-pole2x63A5-pole
25 mm² max.100A 06 800 0313
3.2 8xSchuko1x16A5-pole1x32A5-pole2x63A5-pole
25 mm² max.100A 06 800 0314
3.3 8xSchuko0x16A5-pole2x32A5-pole2x63A5-pole
25 mm² max.100A 06 800 0315
12
7
Visual depic-tion
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
4.1 8xSchuko4x16A5-pole0x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0316
4.2 8xSchuko3x16A5-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0317
4.3 8xSchuko2x16A5-pole2x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0318
4.4 8xSchuko1x16A5-pole3x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0319
4.5 8xSchuko0x16A5-pole4x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0320
5.1 16xSchuko2x16A5-pole0x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0321
5.2 16xSchuko1x16A5-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0322
5.3 16xSchuko0x16A5-pole2x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0323
13
8
Visual depic-tion
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
6.1 12xSchuko3x16A5-pole0x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0324
6.2 12xSchuko2x16A5-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0325
6.3 12xSchuko1x16A5-pole2x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0326
6.4 12xSchuko0x16A5-pole3x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0327
7.1 8xSchuko6x16A3-pole2x16A5-pole0x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0328
7.2 8xSchuko6x16A3-pole1x16A5-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0329
7.3 8xSchuko6x16A3-pole0x16A5-pole2x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0330
14
9
Visual depic-tion
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
8.1 6x16A3-pole4x16A5-pole0x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0331
8.2 6x16A3-pole3x16A5-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0332
8.3 6x16A3-pole2x16A5-pole2x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0333
8.4 6x16A3-pole1x16A5-pole3x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0334
8.5 6x16A3-pole0x16A5-pole4x32A5-pole1x63A5-pole
25 mm² max.100A 06 800 0335
9.1 6x16A3-pole2x16A5-pole0x32A5-pole2x63A5-pole
25 mm² max.100A 06 800 0336
9.2 6x16A3-pole1x16A5-pole1x32A5-pole2x63A5-pole
25 mm² max.100A 06 800 0337
9.3 6x16A3-pole0x16A5-pole2x32A5-pole2x63A5-pole
25 mm² max.100A 06 800 0338
15
10
10.1 6x16A3-pole6x16A5-pole0x32A5-pole
16 mm² max.80A 06 800 0339
10.2 6x16A3-pole5x16A5-pole1x32A5-pole
16 mm² max.80A 06 800 0340
10.3 6x16A3-pole4x16A5-pole2x32A5-pole
16 mm² max.80A 06 800 0341
10.4 6x16A3-pole3x16A5-pole3x32A5-pole
16 mm² max.80A 06 800 0342
10.5 6x16A3-pole2x16A5-pole4x32A5-pole
16 mm² max.80A 06 800 0343
10.6 6x16A3-pole1x16A5-pole5x32A5-pole
25 mm² max.100A 06 800 0344
10.7 6x16A3-pole0x16A5-pole6x32A5-pole
25 mm² max.100A 06 800 0345
11 Without elec-trical installa-tion / without submersion hood
Earthing and mounting set for version without electrical installation kit.CAUTION!Damper settings corresponds to the as-semblyconditionwithelectricalfixtures.
06 800 0300
Visual depic-tion
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
1611
7. Submersion hood with mounting panel for individual configuration by customers
Item No: Selec-tion
Yes 06 800 0346
8. Connection cable for electrical installation kit
Item No: Selection5x35mm²connection;3metres 06 800 00904x35mm²connection;3metres 06 800 00915x25mm²connection;3metres 06 800 00924x25mm²connection;3metres 06 800 00935x16mm²connection;3metres 06 800 00944x16mm²connection;3metres 06 800 0095
Cable cross-section based on list with electrical installation kit not in connection with the main fuse
1712
10. Step protection
Item No: SelectionStandardmetal(integrated) 06 800 0058Plastic(forinsertion) 06 800 0056Metal(forinsertion) 70 071 6621
9. Main fuse and/or clamping unit (optional at height 3 = 1065mm)
Visual depic-tion Description Item No: Selec-
tionMainfuseNH-00max.100A/with3.5mconnectioncable5x35mm²
06 664 0550
MainfuseNH-00max.100A/with3.5mconnectioncable4x35mm²
06 664 0551
MainfuseNH-00max.100A/with3.5mconnectioncable5x25mm²
06 664 0552
MainfuseNH-00max.100A/with3.5mconnectioncable4x25mm²
06 664 0553
MainfuseNH-00max.80A/with3.5mcon-nectioncable5x16mm²
06 664 0554
MainfuseNH-00max.80A/with3.5mcon-nectioncable4x16mm²
06 664 0555
IP68 housing with 16-35 mm² clamp, 35 mm² cable for elec. installation kit for con-nection cable, Ø34-45 mm (not included with
delivery)
06 664 0556
IP68 housing with 16-35 mm² clamp, 25 mm² cable for elec. installation kit for con-nection cable, Ø34-45 mm (not included with
delivery)
06 664 0557
IP68 housing with 16–35 mm² clamping block 16 mm² cable for elec. installation kit for connection cable, Ø27-34.5 mm (not includ-
ed with delivery)
06 664 0558
Cable cross-section based on list with electrical installation kit
Item No: SelectionYes 06 800 0060
11. Lid lock heater (optional)
18
13
14. AccessoriesVisual de-piction Description Item No: Selection
HexagonalsocketspannerSW14T-shape 700699600
Valve key for main hydrant T-shape 700710500
13. Fresh water 1/2"-1" quick disconnect (fibre) coupler (optional at height 3 = 1065mm)
Visual de-piction Description Item No: Selec-
tion1xFreshwaterconnection 7007079012xFreshwaterconnection 7007079023xFreshwaterconnection 7007079034xFreshwaterconnection 7007079041xFreshwaterconnectionwithmainhydrant 7007079052xFreshwaterconnectionwithmainhydrant 7007079063xFreshwaterconnectionwithmainhydrant 7007079074xFreshwaterconnectionwithmainhydrant 7007079081xFreshwaterconnectionwithwatermeter 7007079092xFreshwaterconnectionwithwatermeter 7007079103xFreshwaterconnectionwithwatermeter 7007079114xFreshwaterconnectionwithwatermeter 7007079121xFreshwaterconnectionwithmainhydrantand water meter
700707913
2xFreshwaterconnectionwithmainhydrantand water meter
700707914
3xFreshwaterconnectionwithmainhydrantand water meter
700707915
4xFreshwaterconnectionwithmainhydrantand water meter
700707916
12. Waste water 2" Storz (fibre) coupler (optional at height 3 = 1065mm)
Item No: SelectionYes 06 800 0059Visual depic-
tion Description Item No: Selec-tion
MainfuseNH-00max.100A/with3.5mconnectioncable5x35mm²
06 664 0550
MainfuseNH-00max.100A/with3.5mconnectioncable4x35mm²
06 664 0551
MainfuseNH-00max.100A/with3.5mconnectioncable5x25mm²
06 664 0552
MainfuseNH-00max.100A/with3.5mconnectioncable4x25mm²
06 664 0553
MainfuseNH-00max.80A/with3.5mcon-nectioncable5x16mm²
06 664 0554
MainfuseNH-00max.80A/with3.5mcon-nectioncable4x16mm²
06 664 0555
IP68 housing with 16-35 mm² clamp, 35 mm² cable for elec. installation kit for con-nection cable, Ø34-45 mm (not included with
delivery)
06 664 0556
IP68 housing with 16-35 mm² clamp, 25 mm² cable for elec. installation kit for con-nection cable, Ø34-45 mm (not included with
delivery)
06 664 0557
IP68 housing with 16–35 mm² clamping block 16 mm² cable for elec. installation kit for connection cable, Ø27-34.5 mm (not includ-
ed with delivery)
06 664 0558
19
Underground distribution system EK 600with swivel manhole cover
EK 600Inside width: 400 x 650 mm
Overall outer dimensions: 683 x 900 mm
Overall height without NH-00 back-up fuse: approx. 640 or 860 mm
Overall height with NH-00 back-up fuse: approx. 1080 mm
Paveable stainless steel manhole cover and manhole frame:
up to D 400 acc. to DIN EN 124
Paving height: 65 mm
Maximum fuse protection: 100 A
Connected load of the optional electric heater:
180 W
Protection class of electric distributor: closed: IP58 acc. to DIN EN 60 529 open: IP54 acc. to DIN EN 60 529
Top view(paveable cover)
Area of application
Marketplace designs that fit into urban landscapes, as well as the supply of marketplaces, individual stalls and events with electricity, fresh water and more. Hidden underground and well protected against vandalism and damage. Fast and easy access by authorised personnel.
Side view Front view
804
“X”
as p
er c
on
fig
ura
tio
n
LW400x650750
20
Manhole Confi gurator EK 600
Item No 70 071 7500 / 000
Change index: 3
214
3. Manhole body
4. Test category(please make a selection)
Man-hole height
Description Paveable cover Item No:
Chequered stud plate cover Item No:
Concrete-lined cover Item No:
Visual depiction
Hei
ght 1
= 6
40 m
m - Elec. installation kituptomax.32Asocket only for var. 2; 3; 4; 7; 8- No water and/or waste water possible- No main fuse and/or clamping unit possible
06 600 05011xsize220frame
06 600 0501/0011xsize220frame
06 600 0501/0021xsize220frame
Hei
ght 2
= 8
60 m
m - Electrical installa-tion kit: no restric-tions- No water and/or waste water possible- No main fuse and/or clamping unit possible
06 600 05022xsize220frame
06 600 0502/0012xsize220frame
06 600 0502/0022xsize220frame
Hei
ght 3
= 1
080
mm No restrictions 06 600 0503
3xsize220frame06 600 0503/0013xsize220frame
06 600 0503/0023xsize220frame
Test category Item No: SelectionDIN EN124-B125 06 800 0053DIN EN124-D400 06 800 0052
= Please mark requested variant
225
5. Installation, operation and maintenance guidelines (please make a selection)
Language Item No: SelectionGerman 70 070 0900 / 000English 70 070 0900 / 001
Other languages available on request
6. Electrical installation kit (please make a selection)
Visual de-piction
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
1.1 4xSchuko1x16A5-pole1x63A5-pole
25 mm² max.100A 06 600 0301
1.2 4xSchuko1x32A5-pole1x63A5-pole
25 mm² max.100A 06 600 0302
2.1 4xSchuko2x16A5-pole0x32A5-pole
16 mm² max.80A 06 600 0303
2.2 4xSchuko1x16A5-pole1x32A5-pole
16 mm² max.80A 06 600 0304
2.3 4xSchuko0x16A5-pole2x32A5-pole
16 mm² max.80A 06 600 0305
3.1 8xSchuko1x165-pole
16 mm² max.80A 06 600 0306
3.2 8xSchuko1x32A5-pole
16 mm² max.80A 06 600 0307
4.1 3x16A5-pole0x32A5-pole
16 mm² max.80A 06 600 0308
4.2 1x16A5-pole2x32A5-pole
16 mm² max.80A 06 600 0309
4.3 2x16A5-pole1x32A5-pole
16 mm² max.80A 06 600 0310
4.4 0x16A5-pole3x32A5-pole
16 mm² max.80A 06 600 0311
236
7. Submersion hood with mounting panel for individual configuration by customers
Item No: Selection
Yes 06 600 0366
Visual depic-tion
Configuration Cable cross-sec-tion
Back-up fuse rated current
Item No: Selec-tion
5.1 2x16A5-pole0x32A5-pole1x63A5-pole
25 mm² max.100A 06 600 0312
5.2 1x16A5-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 600 0313
5.3 0x16A5-pole2x32A5-pole1x63A5-pole
25 mm² max.100A 06 600 0314
6.1 2x16A3-pole1x16A5-pole1x63A5-pole
25 mm² max.100A 06 600 0315
6.2 2x16A3-pole1x32A5-pole1x63A5-pole
25 mm² max.100A 06 600 0316
7.1 2x16A3-pole2x16A5-pole0x32A5-pole
16 mm² max.80A 06 600 0317
7.2 2x16A3-pole1x16A5-pole1x32A5-pole
16 mm² max.80A 06 600 0318
7.3 2x16A3-pole0x16A5-pole2x32A5-pole
16 mm² max.80A 06 600 0319
8.1 4x16A3-pole1x16A5-pole
16 mm² max.80A 06 600 0320
8.2 4x16A3-pole1x32A5-pole
16 mm² max.80A 06 600 0321
9 Without elec. installation / without sub-mersion hood
Earthing and mounting set for version without electrical installation kit.CAUTION!Damper settings corresponds to the as-semblyconditionwithelectricalfixtures.
06 800 0300
24
7
8. Connection cable for electrical installation kit
Item No: Selection5x25mm²connection;3metres 06 800 00924x25mm²connection;3metres 06 800 00935x16mm²connection;3metres 06 800 00944x16mm²connection;3metres 06 800 0095
Cable cross-section based on list with electrical installation kit not in connection with the main fuse and/or clamping unit
9. Main fuse and/or clamping unit(optional at height 3 = 1080 mm)
Visual depic-tion Description Item No: Selec-
tionMainfuseNH-00max.100A/with3.5mconnectioncable5x25mm²
06 664 0652
MainfuseNH-00max.100A/with3.5mconnectioncable4x25mm²
06 664 0653
MainfuseNH-00max.80A/with3.5mcon-nectioncable5x16mm²
06 664 0654
MainfuseNH-00max.80A/with3.5mcon-nectioncable4x16mm²
06 664 0655
IP68 housing with 16-35 mm² clamp for connection cable, Ø 34-45 mm (without connection
cable)
Cable for elec. installation kit 25 mm²
06 664 0657
IP68 housing with 16-35 mm² clamping block for connection cable, Ø 27-34.5 mm(withoutconnectioncable)
Cable for elec. installation kit 16 mm²
06 664 0658
Cable cross-section based on list with electrical installation kit not in connection with fresh water or waste water
10. Step protection
Item No: SelectionStandardmetal(integrated) 06 600 0058Metal(forinsertion) 70 071 6615
25
8
Item No: SelectionYes 06 600 0060
11. Lid lock heater (optional)
12. Waste water 2" Storz (fibre) coupler (optional at height 3 = 1080mm)
13. Fresh water 1/2"-1" quick disconnect (fibre) coupler (optional at height 3 = 1080mm)
Item No: SelectionYes 06 600 0059
Visual de-piction Description Item No: Selection
1xFreshwaterconnection 7007165042xFreshwaterconnection 7007165081xFreshwaterconnectionwithmain hydrant
700716502
2xFreshwaterconnectionwithmain hydrant
700716506
1xFreshwaterconnectionwithwatermeter 7007165032xFreshwaterconnectionwithwatermeter 7007165071xFreshwaterconnectionwithmain hydrant and water meter
700716501
2xFreshwaterconnectionwithmain hydrant and water meter
700716505
Not in connection with the main fuse or clamping unit
Not in connection with the main fuse or clamping unit
26
9
14. Accessories
Visual de-piction Description Item No: Selection
HexagonalsocketspannerSW14T-shape 700699600
Valve key for main hydrant T-shape 700710500
27Langmatz GmbH Am Gschwend 10 Telephone +49 88 21 920-0 E-mail [email protected] Garmisch-Partenkirchen | Germany Fax +49 88 21 920-159 Website www.langmatz.de
The compact satellite distributor from Langmatz is a quality product combining both innovati-ve and tried-and-tested features. The compact distributor extends power to the exact point where it is required. It is no longer necessary to lay any extension cables. Two height variants ensure that the compact satellite power distributor can be used even in situations with minimum cover depth.The tried-and-tested flood proof compartment principle protects the technical equipment from flooding and heavy rain.
Advantages Flexibility down to the last detail
Modular construction
3x Schuko socket or 1x CEE 32 A outlets possible
Flood proof compartment protects fixtures from flooding
Available with or without cable outlet
Access to locking mechanism only possible with special construction key
Stability and safety• Maximum load in accordance with DIN EN 124/B 125
EK 602 compact satellite power
distributor, open, cable outlet closed
EK 602 compact satellite power distributor
EK 602 compact satellite power
distributor, closed, cable outlet open
Technical data Designation: Langmatz EK 602 compact satellite distributor
Material: Manhole body/base plate: Plastic – Polypropylene (PP) Steel frame: Stainless steel A2 – (1.4301) Manhole cover: Stainless steel A2, diamond plate – (1.4301) Flood proof compartment in interior: Stainless steel A2 – (1.4301)
Dimensions: L/W/H: 357/357/462 mm orL/W/H: 357/357/832 mm
Weight: approx. 35 kg or 40 kg (for 832 mm height variant)
Load class: DIN EN 124/B 125
28
Accessories Items to be ordered separately
Manhole body
Transport lugs
Folding cover
ConstructionCable outlet lid with hinge
Name Article number Image
Protective tube seal, Ø 110 mm 081863110
Steel key 700713001
Lifting hook 740006805
Cable outlet
Strain relief rail
Langmatz GmbH Am Gschwend 10 Telephone +49 88 21 920-0 E-mail [email protected] Garmisch-Partenkirchen | Germany Fax +49 88 21 920-159 Website www.langmatz.de
Subj
ect t
o ch
ange
with
out n
otice
| As
of 0
6-20
17
29
Underground distribution system EK 880 with horizontally swivelling flood proof compartment
Advantages | manhole and housing
• High flexibility in the configurations
• Safe protection of the electronics/electrical fixtures against water ingress using the proven submersion
cover principle
• High mechanical strength
• High-quality stainless steel design
• Covers can be used as a work platform
• Safe cable routing, as a cable catch rail is installed in front and after the cable swivelling area
• No transfer of cover vibrations onto fixtures, as there are two completely decoupled systems
Advantages | cover
• Swivel manhole cover: Can be operated by one person without heavy lifting
• Cover with wide opening angle (100°) and self-arrest mechanism
• Fully removable cover
• Height-adjustable
• Safety lock
• Positive opening function in the cover locking mechanism for easy opening in any weather
• Non-shrink seals for quiet covering
• Small frame width so that the manhole cover blends inconspicuously into the roadside environment
• Linear frame contour
Area of application
Safe underground accommodation of electricity and telecommunication components, hidden underground and well protected against vandalism and damage. Fast and easy access for defined personnel using the Langmatz locking system.
EK 880Inside width: 800 x 1400 mm
Outer dimensions: 1240 x 1580 mm
Closed height: 930 mm
Open height: 2027 mm
Manhole cover: up to D 400 acc. to DIN EN 124
30
Underground distribution system EK 880 with horizontally swivelling flood proof compartment
Housing
• Single-ply stainless steel housing with door
• Door variants:
- closed front
- with vent grille
• Strain reliefs and mounting clamps as designed
• Custom configurations acc. to customer specification
• Cable entry as per application (fed media must be designed and coupled gas-tight to avoid the so-
called snorkel effect)
• Housing size acc. to cable distribution cabinet 82 and/or multifunction housings MFG 8 for telecom-
munication
Manhole cover closed/open
• With 4-part cast iron cover / D 400
Flood proof compartment folded open
• 4-part cast iron cover completely opened
• Flood proof compartment – stainless steel housing – folded out and locked in position
• Free access to installed cable components and cable connections
Service platform provided
• After the folded open housing automatically locks in position, two parts of the cast iron cover are
closed and can be used by the service technician as a platform in front of the housing.
Configuration options
• Switch disconnector fuse units, max. 6 x NH2, 400 A, 3-pole
• Telecommunication equipment
• 19” modular system
• Mounting panel for individual configuration
• Further equipment on request
31
Underground distribution system EK 368 with NH-00 isolator with IP68 connection housing
Area of application
Underground solution for fuse protection, e.g., for object lighting, Christmas lighting and much more. Your equipment is protected in a waterproof housing. Power supply systems can be integrated.
Technical data | manhole design
• Inside width 400 x 650 mm
• Overall height 515 mm
• Manhole cover possible in all standard variants
• Manhole cover: Standard locking mechanisms
• Test class A 15 / B 125 / D 400 acc. to DIN EN 124
• Height adjustment kit (up to 50 mm)
• Cable outlets via set break point in manhole wall
• Top frame
• Galvanised steel frame
• Number of frames/frame height acc. to customer specification
• Base plate
• Other manhole sizes and covers upon request
Technical data | connection housing
• Housing with NH-00 isolator
• Degree of protection: IP68 acc. to DIN EN 60 529
• Housing is mounted on two stainless steel brackets and additionally protected against
contamination using a permanently installed protective mat
• Leak-tight fittings for inlets/outlets
• NH fuse switch disconnector size 00 / 3-pole switchable
• Connection using prism clamps
• Outlet via clamp block on mounting panel
• Other fixtures upon request
32
Underground distribution system EK 838 with integrated cable outlet in cast iron cover
Area of application
Supply of marketplaces, individual stalls and events with electricity, hidden underground and well protected against vandalism and damage.
Advantages
• Integrated cable outlet in cast iron cover
- Fixed stops at two opening angles
- Effective cable protection when driving over manhole
• Manhole cover lockable with open or closed cable outlet
• No above-ground location is needed, as with cable distribution cabinets
• Manhole cover can be opened by one person
Manhole with variable number of frames/frame height
Manhole in standard height (compact manhole K1)
Technical data | manhole
• Inside width 400 x 650 mm
• Manhole cover: Height 95 mm
• Steel frame, galvanised and connected with top frame (no height adjustment possible)
• Outer standard height approx. 680 mm (compact manhole K1)
Alternative: Variable number of frames/frame height acc. to customer request with top frame
(see drawing)
• Base plate
• Installation: Equipment acc. to customer request
Technical data | cover
• Manhole cast iron manhole cover
• Load 125 kN
33
Underground distribution system EK 838 with integrated cable outlet in cast iron cover
Mode of operation
Unlocking the cover
Opening and latching the main cover
Inserting supply linesClosing the main cover, folding cover remains open
Integrated cable outlet in cast iron cover
Folding cover for cable outlet - Large opening angle
Folding cover for cable outlet - Small opening angle
34
Motorway roadside emergency telephone manhole EK 383
Roadside emergency telephone manhole with emergency telephone calibration options and end cap accommodation
Adjustment device for column adjustment range +/- 3°
Surrounding gutter between the fixed and swivelling cover components, to prevent surface water penetration
Advantages
• Lower manhole weight as designed in polycarbonate, simplified handling during assembly
• No concrete foundation required
• Easy cable entry into manhole using set break point elements
• Emergency telephone base and manhole form one unit, easy cabling between end cap and
column
• Comfortable emergency telephone adjustment, adjustment range +/- 3°
• Increased workspace for technician (70 x 65 cm)
• Reserve service cable is attached at the side in manhole, no excavation necessary to release
reserve cable
• End cap mounting with tilting mechanism for ease of installation
• Rain-proof manhole cover with an overlapping hot-dip galvanised steel cover
• Safeguard against unauthorised opening of the cover
• Integrated lifting rod for energy saving opening of the cover with hinges and locking device
• Column base open for emergency telephone connection cable including high-strength
cable gland
• Column has a greater distance from the safety barrier due to its asymmetrical arrangement
35
Motorway roadside emergency telephone manhole EK 383
Technical data
• Outer dimensions: 869 x 1376 mm
• Inside width: 650 x 1165 mm
• Material: Polycarbonate
• Outer standard height: approx. 778 mm (Number of frames/frame height acc. to
customer request)
• Steel frame: galvanised and connected with top frame (no height adjustment possible)
• Cover: overlapping hot-dip galvanised steel cover, 2-part
• Base plate
Closed cover Open cover, telescopic rod as lifting aid
In locked condition In unlocked condition
36
References
Excerpt from our customer list
Utility companies Local authorities, municipalitiesTelecommunications companies System integratorsPublic transport, railways Builders' merchants
Installation companies
Underground distribution systems made by Langmatz are used nationally and internationally. Please contact us for local references in your area.
Subj
ect
to m
odifi
catio
ns |
As
of
07-2
017
Langmatz GmbH Am Gschwend 10 Telefon +49 88 21 920-0 E-Mail [email protected] Garmisch-Partenkirchen | Germany Telefax +49 88 21 920-159 Internet www.langmatz.de
Langmatz is an innovative plastics and metals processing company.
With numerous patents, we are constantly setting new standards.
Rooted in the Bavarian Garmisch-Partenkirchen region, we continuously develop high-quality products that meet interna-
tional standards. We manufacture technologically advanced systems for infrastructure: manholes, underground distribution
systems, solutions for fibre optic networks, signal requesting devices and much more – “Made in Germany” is our motivation
as well as our obligation.
Polycarbonate manholes
Building cable & pipe entry systems
Bird protection equipment
Underground distribution systems
Products for tunnel construction
Signal requesting devices
FTTx-Solutions for optical fibre networks
Street lights
Radio ripple control receivers
Outdoor cabinets and pedestals
Fuse boxes