rev 1.10 / 2018 12 21
PCP-35 capacitor charging module
User manual
Warning! This equipment might be dangerous. Please read user manual before starting operations.
Important note. Module is sensitive to the reverse polarity applied to the
output. If you aren’t sure in your application, please contact the factory for the details.
Overview / Description PCP-35 capacitor charging module is a high-frequency switch-mode converter, which transforms AC input to regulated high voltage DC output to charge capacitors. Output power is over 3500W for modifications with partial discharge (PD) and over 3000J/s for modifications with complete discharge (CD). Output voltage is customer defined in range up to 1500V (4000V on request). Module is “industrial grade” and cannot be used for medical applications without modifications. Cooling
Module is cooled with embedded fan. No external cooling is required. Appearance
Connectors / Pins / Interface signals
INPUT: Blue wires (2pcs) – 230VAC 50/60Hz input
HV OUTPUT: Red wire – HV OUTPUT positive Black wire – HV OUTPUT negative
GROUND: M4 thread Module should be grounded using this thread. It should be done before connecting module to the mains.
Warning! GROUND thread depth is 6mm only. Please use screws of the appropriate length
Grounding policy HV OUTPUT negative and INTERFACE return are internally connected to the
chassis ground. Other grounding policies are available on request
INTERFACE: PLD-20
PIN (color) DESIGNATION DESCRIPTION
1 (-) TEMP Test point Module’s internal temperature test point. Standardly is dysfunctional; but can be supplied on request.
2,4,5,6 (black) Ground PINS 2,4,5,6 are connected to the circuit ground of all internal circuits. The return signal connection for all interface signals should be made to one of these pins.
3 (yellow) Voltage Program
A positive DC voltage applied to this pin controls the output voltage set point.
0-10V corresponds to 0-VMAX
7 (blue) INHIBIT
The high voltage output is inhibited or enabled by this pin
0V – enabled; 5V or free-standing – inhibited
8 (green) Ready Indicator This pin is pulled to the ground, when the output voltage is equal to the program voltage (or higher than the program voltage)
9, 10 (red) +15 V
These pins provide +15V DC that may be used for status LEDs etc.
Maximum output current 50mA
11 (orange) +5 V
This pin provides +5V DC that may be used for status LEDs etc.
Maximum output current 50mA 12, 18 N/C -
13 (white; black mark) Over TEMP
This pin is pulled to the ground in the case of module’s overheating (approx 72ºC)
14 (white; blue mark)
Over Voltage Status
This pin is pulled to the ground when overvoltage occurs. The high voltage output is also disabled when this occurs
15 (green / yellow) End of Charge Indicator
PIN15 is pulled to ground when the output voltage below the program voltage. Elsewise PIN15 is pulled to +15V.
16 (blue / white) Secondary Inhibit
The HV OUTPUT is inhibited (when +15V are applied) or enabled (when 0V are applied or the pin is free standing). This pin should be used only to control parallel operations of two or more power modules.
17 (violet) Voltage Monitor
The voltage at this is a buffered signal proportional to the instantaneous output.
0-10V corresponds to 0-VMAX Current capability 1,5mA; Rout = 1kOhm
1357911131517192468101214161820
19 (white; red mark) Fault Indicator *
This pin is pulled to ground when some failure occurs. The high voltage output is disabled when this occurs
Failures: • output short-circuit • overtemperature • overvoltage • output open circuit • charge timeout
20 (transparent) HV ON Indicator This pin is pulled to the ground, when module provides the power to the load
* see also Faults section
Operations
1. Inhibit the high voltage output (PIN7 of INTERFACE) 2. Set the desired output voltage by applying a DC voltage
to the Voltage Program (PIN3 of INTERFACE) 3. Apply power to the module 4. Enable the high voltage output (PIN7 of INTERFACE) 5. Operate, then Disable the high voltage output,
then disconnect module from the mains
Faults section
Module sets Fault state in the following cases: • overheating (temperature of the module exceeds approx. 72 °C level) • overvoltage (voltage on the load exceeds 110% of VMAX level) • short-circuit at module’s output (triggering threshold is about 0.8-1.0s) • open-circuit at module’s output • charging timeout (value by default is about 5s, other timeouts can be
set by request) For most of faults once the Fault has occurred one should eliminate the Fault cause, afterthen “reboot” the module (this means to DISABLE module and ENABLE it again). Exceptions:
• for open-circuit failure one should remove the power from the module and apply it again
• for overheating failure module may start its operations again if the temperature decreases rapidly (i.e. faster than in 5-10s) down to approx. 65 °C level
Specifications
ELECTRICAL
Input:
Voltage 230 VAC, 50/60 Hz
Output:
Maximal output voltage
(VMAX)
user selectable in 300-1500V range
(up to 4000V on special request)
Maximal output power >3500W (can be achieved in regime
70-100% VMAX, 230VAC input, 25
°C, partial discharge modifications)
>3000J/s (can be achieved in
regime 0-100% VMAX, 230VAC
input, 25 °C, complete discharge
modifications)
Stability 0.5% of VMAX
Pulse to pulse 0.5% of VMAX
Efficiency More than 85%
PFC coefficient ~ 0.90
Protections: from open circuit
from short circuit
from over-temperature
from over-voltage
shut down on charging timeout
Cooling: Forced air (build in fan)
Environment:
Operation temperature +10… +40 °C
Storage temperature -20 … +60 °C
Humidity 90%, non-condensing
MECHANICAL
Dimensions see dimensional drawing below
Weight approx 2.8 kg
Dimensions
AIR
FLOW
Desig
natio
nTy
peDe
scrip
tion
INPU
TCA
BLE
incor
pora
ted
cabl
eLe
ngth
-500
mmFl
ying
lead
s
HV O
UTPU
TCA
BLE
incor
pora
ted
cabl
eLe
ngth
-500
mmFl
ying
lead
s
INTE
RFAC
Eco
nnec
tor
Mole
x 90
130.11
20
Cabl
e inc
lude
d Le
ngth
-300
mmCo
nnec
tor
Mole
x 90
124.00
20 a
ndFl
ying
lead
s
Ôàéë: 429.00.00.000-03Ã×
Øèôð
:
Èíâ. ¹ ïîäë.Ïîäï. è äàòàÂçàì. èíâ. ¹Èíâ. ¹ äóáë.Ïîäï. è äàòàÏåðâ. ïðèìåí. Ñïðàâ. ¹
Ôîð
ìàò
A3
ÎÎÎ
"ÎÅÌ
Òåõ
"
Ëèñò
429.00.00.000-03Ã×
0.95
Ìàñø
òàá
Ìàññ
à
Ëèñò
îâ 1
1:2
Ëèò.
429.00
.00.00
0-03
Ã×
Ãàáà
ðèòí
ûé ÷
åðòå
æ
Êîïè
ðîâà
ë
Ãëèí
ñêèé
Äàòà
Ïîäï
.¹
äîê
óì.
Ëèñò
Èçì.
Ðàçð
àá.
Ïðîâ
.Ò.
êîíò
ð.
Í. ê
îíòð
.Óò
â.
PCP-
35
CABL
ETE
RMIN
ALIN
PUT
GND
INTE
RFAC
E
HV O
UTPU
TCA
BLE
PCP-35-xxxV-XX
23
23
6,50
M4
(6mm
max
scr
ew d
epth
)
50
15
8
32
54 15
15
259
,65
136
153
11
7
M4 m
ount
ing h
ole
on c
hass
is bo
ttom
4x
(4mm
max
scr
ew d
epth
)
184
3
2,50
3
9,50
100
113,16
128
How to order?
PCP-35-XXXX-YY, where XXXX means VMAX voltage (user selectable in 300V-1500V range, up to 4000V on special request) YY means either CD (complete discharge modification) or PD (partial discharge modification); if YY is missed PD modification will be supplied Examples (the most popular modifications): PCP-35-300V-PD 300V, partial discharge PCP-35-500V-PD 500V, partial discharge PCP-35-700V-PD 700V, partial discharge PCP-35-1000V-PD 1000V, partial discharge PCP-35-1000V-CD 1000V, complete discharge PCP-35-1500V-CD 1500V, complete discharge
Other modifications are available on request.