15
Patient Care Devices Patient Care Devices HIMSS IHE Showcase HIMSS IHE Showcase 09 Review & ‘10 Planning 09 Review & ‘10 Planning

Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

Embed Size (px)

Citation preview

Page 1: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

Patient Care DevicesPatient Care Devices

HIMSS IHE ShowcaseHIMSS IHE Showcase’’09 Review & ‘10 Planning09 Review & ‘10 Planning

Page 2: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

2

General ’09 Feedback

General observations from ‘09…General observations from ‘09… Great exposure & interest!

PCD Message repeated too often / took too long to communicate

Too little vendor system exposure (vs. too much in the past)

PCD still an Interoperability Island

Live vs. Staged? (e.g., heart alarm) – Show live as much as possible!

Page 3: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

3

General ’09 Feedback

General observations from ‘09…General observations from ‘09… Engagement of tour participants to

pursue / promote PCD solutions.

More clearly address “where do I buy this?” (user’s guide? Theater? Certification/Connectathon testing?)

Desire for “private” vendor tours – guidelines? Limitations?

Utilize “distributed demo” opportunity? Showcase screen for remote data sources?

Page 4: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

4

General ’09 Feedback

General observations from ‘09…General observations from ‘09… Pre-conference vendor-specific video

that could be presented in vendor’s area

Off-hours vendor-specific tours?

Paul’s Shot-Pump Profile!

Page 5: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

5

Welch AllynWelch AllynConnexConnexTMTM

DataDataManagementManagement

SystemSystem

Vital Signs Monitor

GEGE

AwareAwareGatewayGateway

Patient Monitor, Ventilator

PhilipsPhilips

IntellivueIntellivueInformationInformation

CenterCenter

Patient Monitor, Ventilator

Emergency Care Intensive Care

LiveDataLiveData

OR-DashBoardOR-DashBoard

GE GE

CentricityCentricity®®

PeriopPeriopAnesthesiaAnesthesia

DraegerDraeger

InnovianInnovian®®

Solution SuiteSolution Suite

Patient Monitor, Anesthesia Sys

B. BraunB. BraunDoseTracDoseTracTMTM

InfusionInfusionManagementManagement

SoftwareSoftware

InfusionDevices

Perioperative Care

PhilipsPhilips

Intellivue ClinicalIntellivue ClinicalInformationInformation

PortfolioPortfolio

PCD @ HIMSS ’07 Systems

Page 6: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

6

PCD @ HIMSS ’08 Systems

Page 7: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

7

GE GE CentricityCentricity®®

Periop Anes.Periop Anes.

Enterprise

DOC

DOC

Patient Patient

LiveDataLiveDataOR –OR –

DashBoardDashBoardTMTM

DOR = Device Observation Reporter IOP = Infusion Order Programmer

DOC = Device Observation Consumer IOC = Infusion Order Consumer

AR = Alarm Reporter / AM = Alarm Manager

PDQ/PAMServer

PhilipsPhilipsIntelliVueIntelliVue ClinicalClinical

Info PortfolioInfo Portfolio

DOC DOC

DraegerDraegerInnovianInnovian® ® WebWeb

CapsuleCapsule

GE GE CentricityCentricity®®

EnterpriseEnterprise

DOC

LiveData LiveData Alert ManagerAlert Manager

PhilipsPhilipsEmerginEmergin

AM

OR

TimeServer

Step-DownICU

AM

Hospital Bed,BIS Monitor

CapsuleCapsuleDataCaptorDataCaptor

DOR,AR

Patient Monitor

DOR,AR

PhilipsPhilipsIntelliVueIntelliVue

Info. CenterInfo. Center

AR DOR,AR

CernerCerner

CareMobileCareMobileTMTM

DOCIOP

AC

DOR,AR

Hospital Bed,VS Monitor

CernerCerner

CareAwareCareAwareTMTM

DOR,AR

InfusionDevices

IOC

B.

Bra

un

B.

Bra

un

Ho

sp

ira

Ho

sp

ira

Ca

rdin

al

Ca

rdin

al

Patient Monitor,Ventilator

DOR

GEGEAwareAware

GatewayGateway

DOR,AR

InfusionDevices

IOC

B.

Bra

un

B.

Bra

un

Ho

sp

ira

Ho

sp

ira

Ca

rdin

al

Ca

rdin

al

Patient Monitor,Anesthesia Sys

DOR, AR

DraegerDraeger InfinityInfinityGatewayGateway

DOR,AR

InfusionDevices

B.

Bra

un

B.

Bra

un

Ho

sp

ira

Ho

sp

ira

Ca

rdin

al

Ca

rdin

al

Patient Patient

PolycomPolycomWirelessWirelessPhonePhone

AlarmClient

CapsuleCapsule

SISSISPeriopPeriop

SolutionSolutionDOC

CernerCerner

CareMobileCareMobileTMTM

DOCIOP

IHE PCD ’09 Showcase

Page 8: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

8

Considerations for 2010 Showcase

PCD Message should…PCD Message should…

Be fresh (3 years w/ care context!)

Accommodate >2X vendors!

Relevant to Current U.S. HIT Activities (ARRA)

Problem / Profile Focus?

Increased integration with other areas (Alarms, XDS, Continua, …)

Page 9: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

9

Considerations for 2010 Showcase

Problem / Problem / ProfileProfile Focus… Focus… Integration with EHR (DEC + RTM)

Patient Safety (ACM & PIV)

Multiple Contexts (HITSP/CmDC & RMON/SDE#2/Home, Emergency Responder, ED/OR/ICU/… )

Quality & Workflow Efficiency (MEM, DPI, IDCO, ICE-PAC, …)

Research & Comparative Effectiveness (RTM, Device Semantics, …)

Page 10: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

10

Considerations for 2010 Showcase

Problem / Problem / ProfileProfile Focus… Focus… Integrate “new directions” materials in

core walls (vs. separate area)

Page 11: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

11

IHE Patient Care Devices (PCD)

(6” Wide Walls)

Continua IDCO

Multi-Context Connectivity

WAN

EHR / XDS

EHR

Integration

Distributed / Remote Demos

Patient Safety

Quality &

Efficiency

New Directions / Posters / …

Page 12: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning
Page 13: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

13

ARRA Specifics From HITECH Section 3002

1. Technology to protect privacy and security (Protect S&P)

2. A nationwide health information infrastructure that supports exchange of health information (Health Info Infrastructure)

3. The use of certified health record for each person in the US by 2014 (Pervasive Certified Health Record)

4. Technologies to account for disclosures of health information (Disclosure Audit)

Page 14: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

14

ARRA Specifics From HITECH Section 3002

5. The use of certified electronic health records to improve the quality of health care, such as by promoting the coordination of health care and improving continuity of health care among health care providers, by reducing medical errors, by improving population health, by reducing health disparities, by reducing chronic disease, and by advancing research and education. (Quality)

6. Technologies that allow individually identifiable health information to be rendered unusable, unreadable, or indecipherable to unauthorized individual (IIHI Unusable)

7. The use of electronic systems to ensure the comprehensive collection of patient demographic data (Demographic Data)

8. Technologies that address the needs of children and other vulnerable populations (Needs of Vulnerable)

Page 15: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning

15

IHE Patient Care Devices (PCD)