Part No. 29220508RCSKODA
Octavia Saloon 06/04Octavia Estate 01/05 Octavia Scout 03/07
Installation of the towing electrics kit must be undertaken by a specialist workshop or an appropriately qualified person. Before starting work, you must read the installation instructions through completely. After installing the towing electrics kit, the installation instructions should be kept with the vehicle service documentation.
All claims under the guarantee will lapse in case of improper use or modification of the towing electrics kit or any of its component parts. When driving without a trailer or load carrier, any adapter installed must be removed from the electrical socket. We reserve the right to alter the design, content or colour. We accept no liability for any errors in these instructions. All details and illustrations are non-binding.
Fitting instructions
In case of missing a rear fog lamp on the trailer, it should be retrofitted.
We accept no responsibility and give no guarantee for technical and electrical modifications made after the initial operation of the towing electrics kit by the vehicle manufacturer and which may lead, for example to malfunction of the trailer socket or its peripheries.
The trailer module is not diagnostics-capable. If the manufacturer’s diagnostics processes or software-supported test mechanisms generate error reports directly or indirectly linked with trailer operation, the trailer module must be disconnected from the leads to the trailer socket and a new diagnostic process initiated.
Electric wiring kit for towbars / 13-pin / 12 Volt / ISO 11446
IMP
OR
TAN
T!
1/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
19-27
11-16
3-9
3x 10x 5x3x2x
MANUAL
20A
2x
15A
2x
4x
2/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
Not needed!
SYMBOL EXPLANATION
+ -
15+
+-
30+
Reverse
B+/30
20A
left (58-L) respectively right (58-R) tail light
stop light (54) / high mounted, third stop light (54)
turn signal indicator left
turn signal indicator right
rear fog light(s)
reversing light(s)
Permanent power supply / 13pin socket, chamber 9
charging wire for trailer fridge / 13pin socket, chamber 10
trailer / trailer recognition
Permanent current power supply
Ground or Earth (31)
ground connection battery terminal lug
positive connection battery terminal lug
fuse / fuse capacity 20 Ampère
12V
P
cigarette lighter /accessory socket
loudspeaker / buzzer
Park Distance Control
switch / source of function
Connect together
Disconnect
Look at / See further information
Look carefully at selected area
Present / Occupied / OK
Not present / Not occupied / Not OK
left
right
acoustic indication
attention / important advice
everse
1
3/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
90010216
Co
Co
ATTENTION!
The vehicle's cooling capacity may have to be increased when retrofitting a trailer coupling! You must observe the manufacturer's instructions!!
ATTENTION!
MANUAL
In order to avoid mal-functions and damage to the vehicle’s electrical system the earth terminal must be disconnected from the vehicle’s battery before starting work!
Both the trailer module and the vehicle’s control unit for the electrical system can be damaged during work on the CAN data bus connections if the battery is not disconnected!
Please pay attention to the manufacturer’s instructions when disconnecting and reconnecting the vehicle’s battery!
90220083
Choose direction90500311
90220096
5/58-R
6/54STOP
1/L
4/R
2
ISO 11446
3/311-8
YL
BL
GN
WT
BR
RD
7/58-L
Reverse8
12
1110
139
9+
-20 amp.
30+
10+ -15 amp.
15+
BK
PK
OR
WT/RD
GY
WT/BK
21W
42W
21W
52W
63W
52W
42W
240W
180W
Belegung der Steckdose / Maximale AusgangsleistungSocket configuration / Maximum power outputCorrespondance des contacts de la prise / Puissance de sortie maximaleAbbinamento della presa / Uscita di alimentazione massimaIndeling van de stekkerdoos / maximaal uitgangsvermogen
90020157
90500234
90220068
2 3
4 5
6 8
7
CLICK
4/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
D FGB IE
RD
BK
GN
OR
VT
PK
BL
YL
WT
BR
GY
Black Schwarz Negro Noir Nero
Red Rot Rojo Rouge Rosso
Green Grün Verde Vert Verde
Orange Orange Naranja Orange Arancione
Violet Violett Violeta Violet Viola
Pink Pink Pink Rose Rosa
Blue Blau Azul Bleu Blu
Yellow Gelb Amarillo Jaune Giallo
White Weiss Blanco Blanc Bianco
Brown Braun Marrón Brun Marrone
Grey Grau Gris Gris Grigio
NL NP SDK
Preto Zwart Sort Svart
Vermelho Rood Rød Rød Röd
Verde Groen Grøn Grønt Grön
Laranja Oranje Orange Orange Orange
Violeta Violet Violet Fiolett Violett
Cor-de-Rosa Paars Pink Pink Rosa
Azul Blauw Blå Blått Blå
Amarelo Geel Gul Gult Gul
Branco Wit Hvid Hvitt Vit
Marrom Bruin Brun Brunt Brun
Cinzento Grijs Grå Grått Grå
CZFIN H
Musta Cerná Fekete
Punainen Cervená Piros
Vihreä Zelená Zöld
Oranssi Narancs
Violetti Fialová Ibolya
Pinkki Ruzová Rózsaszín
Sininen Modrá Kék
Keltainen •lutá Sárga
Valkoinen Bílá Fehér
Ruskea Hnedá Barna
Harmaa •edá Szürke
PL
Czarny
Czerwony
Zielony
Pomaranczowy
Fioletowy
Rózowy
Niebeski
Zólty
Bialy
Brazowy
Szary
Svart
Oran•ová
90500580
90220098
Important! Please note informations in picture 1!
X00000000ooooooooooooooooo
x0_0/00.0000
90220097
Important! Please note informations in picture 1!
X00000000ooooooooooooooooo
x0_0/00.0000
9
10
11
12
CLICK
5/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
90220088
90220100
YL/WT
90220101
YL/WT
WT/YL
WT/YL
90220099
90270323
BK
YL
RD/YL
RD/BL
RD
90270295
13 14
15
16
17 18
6/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
Octavia 2009 OR/BR
OR/GN
Important! Please note informations in picture 1!
Important! Please note informations in picture 1!
90270327
OR/BR (chamber 16)
OR/GN (chamber 15)
BK
YL
OR/BRYL
OR/GNBK
19
20
90270327
OR/BR
OR/GN
Octavia 2008
BK
YLOR/BR YL
OR/GN BK
Network control unit position "G" 12 pin connector (BK) chambers 7+8
H G
D C B A
EF
OR/BR (chamber 7)
OR/GN (chamber 8)
CAN-Data Wire
CAN-Data Wire
Connector 52-pin (BR)
7/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
90220090
90270337
90270338
90220102
Open secondary lock!
B+/30
90220104
21 22
23
24
25
45
RD/YL
RD
44
RD/BL
43
RD
45RD/YL
RD/BL
4443
8/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
90220083
90220103
Close secondary lock!
90220094
SERVICE
90270310
MANUAL
SKODA
SKODA MANUAL SERVICE
SKODA
MANUAL
90270309
26 27
28 29
30 31
32
15AFuse chamber 45
45 44
43
20A
Fuse chamber 44
15A
Fuse chamber 43
90270339
WT
OPTIONAL for voltage control relay
Part-no.22400511RC
+_
15 amp.+ -
15+
90500762
GY
+_
9/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
90500507
everse
MANUAL
90500004
90500544
Vehicles with park assist systems
The automatic deactivation of the rear park assist system in trailer operation will be effected by means of the subsequent coding of the park assist control unit:
Only vehicles until model year 07 (MY07)
· Vehicle self-diagnosis· Gateway assembly list· 76 – park assist system· 07 – code control unit· Add the figure 10000 to the current coding & reprogramme
Vehicles from model year 08 (MY08) on:
• Vehicle self-diagnosis• Gateway assembly list• 10 - park assist system II / parallel park assist• 008 Coding (service $22)• Byte 0 - bit pattern xxxxxxx1(x = accept the default values in the input field for this purpose activate input mode (BIN) !)• confirm with OK !
NOTE:
If the vehicle's rear fog lamp does not switch off automatically in trailer mode the following code must be entered in addition to the aforementioned configuration of the central electrical system:
Vehicle self-diagnosis
• 09 Electronic central electrical system• 007 Coding (service 1A)• Vehicle's electrical system controller coding long • Byte 8 - bit pattern x1xxxxxx (x = accept the default values in the input field for this purpose activate input mode (BIN) !)• confirm with OK !·
90500332
Optional: Adapter socket 62400003
13-pin 7-pin
Set up trailer operation
General
After the installation of the electric kit, the obligatory trailer lighting as well as the trailer indicator control which is statutory in a several countries are guaranteed without having to make any connections on the vehicle! The message “Control unit incorrectly coded“ will, however, appear in the fault memory ( 19 – Diagnosis interface for data bus)! Yet this entry has no effect on the other functions and can be ignored until your next regular service appointment. We recommend the connection via the factory-mounted service tester (VAS 5051 / 5052) within the framework of the annual service intervals!
Please effect coding as follows:
• Vehicle self-diagnosis • Gateway assembly list• 19 – diagnosis interface for data bus• 007-Coding (service $1A) \ Read / write long coding• 69 – trailer function ( switch to coded!)
90500700
33 34
35 36
37
10/1087220660/ 04.12.2009
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL