17
Panasonic Expérience • Leadership in Japon : CO2 Models • Most famous manufacturer of compressor in the world(high technology of inverter) • High experience in Nordic countries ( low temperatures )

Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Embed Size (px)

Citation preview

Page 1: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Panasonic Expérience

• Leadership in Japon : CO2 Models

• Most famous manufacturer of compressor in the world(high technology of inverter)

• High experience in Nordic countries

( low temperatures )

Page 2: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

French Market NF PAC Certification

• Zero Interest Loan ( ECO PTZ)

• Tax Credit = 25 %

Page 3: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Strength : Price Positioning VS the main

leader on French Market : DAIKIN

Page 4: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Strength of range

• Wide range: 7Kw to 16KW

( ex: Estia range starts to 9 Kw )

• Mono bloc / Bi bloc

• Single phase / Tri phases

• Heating / cooling / Sanitary water / Solar kit / replace or add to boiler

• Flexibility = New constructions, Rénovation or full substitution

Page 5: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Strength of product• Protection: - 2 or 3 ELCB (according to power of PAC ) - defrost cycle maintained even if stop action from room thermostat =

protection of compressor• Power source of Outdoor unit comes from Indoor unit (Daikin = 2 differents power sources : Outdoor and Indoor units)• Back up heater : 3 or 6 kw in 2 stages • 3 way valve delivered with sanitary tank• Compact design = space saving installationonly 0,35m² / weight 35 Kg (corresponding to little power )• Design of front panel = easy visibilty of control panel and

manometer

Page 6: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Strength / Quality

• Strength: carter of hydrobox very resistant

• Reliable: high qty stuff of components: grundfos pump

• Longevity: stainless steel tank

• Optimization of service and maintenance - accessibility of components due to design of front

panel and hydrobox - fast disassembly thanks to clips ( as boiler )

Page 7: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Strength / Performances

• High performance at low ambient temp A good capacity kept until – 15°C

( Aquarea 12 KW able to compete with 14 or 16 KW from Estia or Altherma )

• Top Class COP ( 12KW = 4.67à + 7°C)

Page 8: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience
Page 9: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity VS Altherma 7 KW

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

8.00

+7 -7 -15

Outdoot Temp

PO

WE

R /

K

W

Panasonic

Altherma

Page 10: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity VS Altherma and Estia

9 KW

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

8.00

9.00

10.00

+7 -7 -15

Outdoor temp

PO

WE

R /

KW

Panasonic

Altherma

Toshiba

Page 11: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

CAPACITY OF AQUAREA / 12 KW (according to inlet water temp)

0

2

4

6

8

10

12

14

7 2 -7 -15

Outdoor temp

Ou

tdo

or

tem

p

30/35

40/45

50/55

PERFORMANCES OF AQUAREA / 12 KW(according to inlet water temp)

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

7 2 -7 -15

Outdoor Temp

CO

P

30/35

40/45

50/55

Capacity and Performances of AQUAREA / 12 KW

Page 12: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity and performances VS Daikin/ 12KW

CAPACITY OF AQUAREA VS ALTHERMA ( inlet water temp 35 °)

0

2

4

6

8

10

12

14

7 2 -7 -15

Outdoor temp

Po

wer

/

KW

Panasonic

Daikin

Page 13: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity of AQUAREA VS Atherma and Estia

12 KW

0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

+7 -7 -15

Outdoor temp

PO

WE

R /

K

W

Panasonic

Altherma

Toshiba

Page 14: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity and Performances of AQUAREA / 14 KW

CAPACITY OF AQUAREA / 14KW (according to inlet water temp)

0

2

4

6

8

10

12

14

16

7 2 -7 -15

Outdoor temp

PO

WE

R /

K

W

30/35

40/45

50/55

PERFORMANCES OF AQUAREA / 14 KW(according to inlet water temp)

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

7 2 -7 -15

Outdoor tempC

OP

30/35

40/45

50/55

Page 15: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity and performances VS Daikin/ 14KW

PERFORMANCES OF AQUAREA VS ALTHERMA 14 KW (inlet water temp 35 °)

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

7 2 -7 -15

Outdoor temp

CO

P Panasonic

Daikin

CAPACITY OF AQUAREA VS DAIKIN 14 KW (inlet water temp 35°)

0

2

4

6

8

10

12

14

16

7 2 -7 -15

Outdoor temp

Po

wer

/ K

W

Panasonic

Daikin

Page 16: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity and Performances of AQUAREA / 16 KW

CAPACITY OF AQUAREA / 16 KW(according to inlet water temp)

0

2

4

6

8

10

12

14

16

18

7 2 -7 -15

Outdoor Temp

PO

WE

R /

KW

30/35

40/45

50/55

PERFORMANCES OF AQUAREA / 16 KW(according to inlet water temp)

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

7 2 -7 -15

Outdoor tempC

OP

30/35

40/45

50/55

Page 17: Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience

Capacity and performances VS Daikin/ 16 KW

PERFORMANCES OF AQUAREA VS ALTHERMA (inlet water temp 35°)

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

7 2 -7 -15

Outdoor temp

CO

P Panasonic

Daikin

CAPACITY OF AQUAREA VS ALTHERMA (inlet water temp 35°)

0

2

4

6

8

10

12

14

16

18

7 2 -7 -15

Oudoor temp

PO

WE

R /

KW

Panasonic

Daikin